Commubox FXA195
Gateways / Interfaces
Intrinsically safe interface for Smart transmitters.
Converts HART protocols to USB signals.
TI404F/00/en
52027095
Commubox FXA195
PLC
- FieldCare
- ToF Tool - FieldTool
A Connection Commubox FXA195
Package
Commubox 270 W
Off
On
FXA191/195
Switch Commubox FXA195
EX
A
Transmitter power- EX
Measured Value
e.g. RMA422
or RN221N
(with communication DELTABAR: * * * * * * * *
ONLINE
1 QUICK SETUP
dsdmdm
df das.
asdas fa
asas la.
Display and
resistor)
2 OPERATING MENU
3 PV 352 mbar
4 SV 0 C
Delete
(optional)
Page
On
FXA191/195
7 8 9
ENDRESS + HAUSER
RMA 422 ,()
.
_<>
0
+*/
-
HART handheld terminal
or 375
FIELD COMMUNICATOR
DXR375
DXR375
L00-FXA195xx-14-00-06-en-001
Note!
Prior to initially commissioning Commubox with the operating program (ToF Tool - Fieldtool Package,
FieldCare, ReadWin or Commuwin), the appropriate drivers must be installed from the CD-ROM supplied (list
of the Endress+Hauser operating programs and versions see Page 4).
Input/output
USB port Personal computer Commubox FXA195 = USB signal as per USB specification.
HART interface Measuring device(s) and Commubox FXA195 = HART signal as per HART specification.
Power supply
Connection For computer: USB port
For transmitter: adapter bushing, 4 mm, independent of polarity
Supply voltage Voltage range: from the USB port of the personal computer, 5VDC.
Current consumption: < 20 mA
2 Endress + Hauser
Commubox FXA195
Electromagnetic Interference Emission to EN 61326, Electrical Equipment Class B. Interference immunity to EN 61326.
compatibility (EMC)
Application Commubox FXA195 can be connected reactionless to protection functions that are graded as SIL 2 in
in conjunction with protec- accordance with IEC 61508.
tion functions
SFF1 60%
TI1 PFDavg2
1) TI = test interval between function tests of the protection function (in years)
2) PFDavg = average probability of dangerous failure on demand
Mechanical construction
Design, dimensions Housing dimensions: 143 x 60 x 30 mm.
External standards Other standards and guidelines that were taken into account when designing and developing FXA195.
and guidelines
EN 60529
Ingress protections for housing (IP code)
EN 61010
Safety requirements for electrical equipment for measurement, control and laboratory use
EN 61326
Interference emission (Class B operating equipment), interference immunity (Appendix A - industrial sector)
Endress + Hauser 3
Commubox FXA195
Ordering information
Commubox FXA195 10 Approval:
G ATEX II (1)GD EEx ia IIC
P FM IS CL.I,II,III Gr.A-G
S CSA IS CL.I,II,III Gr.A-G
Y Special version
20 Additional Option:
1 Basic version
9 Special version
System requirements
Hardware and software Hardware Minimum Endress+Hauser operating program Version
Installation
Scope of delivery A CD-ROM with the following programs is supplied with Commubox FXA195:
USB drivers - these are automatically installed by means of hardware detection. For an example for
installation on Windows 2000, see "Installing the USB driver" onPage 4-8.
PreInstaller - you can use this program to install the USB drivers manually. To do so, you must first start
the program from the CD-ROM, follow the installation instructions and then connect the Commubox to
the personal computer.
ComPortFinder - this program helps you find out which virtual COM port the USB port was set to. To do
so, simply start the program from the CD-ROM.
L00-FXA195xx-20-13-00-en-001
4 Endress + Hauser
Commubox FXA195
L00-FXA195xx-20-13-00-en-002
4. Select "Search for a suitable driver for my device (recommended)" and click "Next >".
L00-FXA195xx-20-13-00-en-003
5. Activate the check box for "CD-ROM drives" and click "Next >".
L00-FXA195xx-20-13-00-en-004
Endress + Hauser 5
Commubox FXA195
6. A driver has been found for the device. Click "Next >".
L00-FXA195xx-20-13-00-en-007
Note!
If the notice "WHQL test failed" appears when installing on Windows XP, please simply continue the
installation.
L00-FXA195xx-20-13-00-en-008
8. The following screen tells you that new hardware has been found.
L00-FXA195xx-20-13-00-en-009
6 Endress + Hauser
Commubox FXA195
9. You are asked to install a driver for this hardware. Click "Next >".
L00-FXA195xx-20-13-00-en-010
10. Select "Search for a suitable driver for my device (recommended)" and click "Next >".
L00-FXA195xx-20-13-00-en-011
11. Activate the check box for "CD-ROM drives" and click "Next >".
L00-FXA195xx-20-13-00-en-012
Endress + Hauser 7
Commubox FXA195
12. A driver has been found for the device. Click "Next >".
L00-FXA195xx-20-13-00-en-013
Note!
If the notice "WHQL test failed" appears when installing on Windows XP, please simply continue the
installation.
L00-FXA195xx-20-13-00-en-014
14. You can use the "ComPortFinder" program to determine the virtual COM port.
Endress+Hauser
GmbH+Co. KG
Instruments International
Colmarer Str. 6
79576 Weil am Rhein
Deutschland
Tel. +49 76 21 9 75 02
Fax +49 76 21 9 75 34 5
www.endress.com
info@ii.endress.com