Sie sind auf Seite 1von 16

2016-12-08-01 Jaime Corts

808 South Pierce Street, Burnet, TX, 78611

4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013


Telephone (786) 502-4836
email customerservice@sdp-us.com

Sheet List
Abbreviation:
Sheet A: Area, BN: Bullnose CI: Cast Iron DB: Decibel EPJF: Expanded Polyethelene Joint Filler VERT: Vertical
ABV: Above BNT: Bent CIR: Circle, Circular, Circuit DBL: Double EQUIP: Equipment VEST: Vestibule
Number Sheet Name AC: Air Conditioning, Acoustical BO: Blow Off CIRC: Circumference DC: Direct Current EQ: Equal VF: Vinyl Fabric
ACC: Access BOT: Bottom CISP: Cast Iron Soil/sewer Pipe DEG: Degree ERP: Emergency Receptacle Panel VFGT: Vinyl Foam Glazing Tape
ACOUST: Acoustical BP: Base Plate, Blueprint, Bypass CITG: Clear Insulating Tempered Glass DEMO: Demolition ESC: Escalator VIF: Verify In the Field
S0.01 Foundation Slab ACST: Acoustic BR: Bedroom, Brick, Brass, Boiler Room CJ: Control Joint DEPT: Department EVAP: Evaporator VIT: Vitreous
S0.02 TYPICAL - Wall Details ACT: Acoustical Tile; Actual BRDG: Bridge, Bridging CL: Centerline, Clearance, Closing, DET: Detail EW: Each Way VLT: Vault IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
AD: Access Door, Area Drain BRG: Bearing Closure,Closet DH: Double Hung EW & C: Electric Wiring and Communication VNR: Veneer BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
A1.02 Finish Schedules ADA: Americans with Disabilities Act of BRKT: Bracket CLG: Ceiling DIAG: Diagonal EWH: Electric Water Heater VOL: Volume ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
1992 BRS: Butyl Rubber Sealant, Brass CLKG: Caulking DIAM: Diameter EX: Exposed Construction, Exit VP: Vapor Proof, Vent Pipe
A4.01 BlowUp floor Plan REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
ADD: Addendum; Addition BRZ: Bronze CLL: Contract Limit Line DIFF: Diffuser EXC: Excavate VR: Vapor Retarder,Vertical Riser EXPRESSLY DESIGNED.
A1.01 Windows & Doors Details AF: Above the Floor BRZG: Brazing CLO: Closet DIM: Dimension EXEC: Executive VS: Vent Stack
AFF: Above Finished Floor BS: Both Sides, Backset, Bluestone CLR: Clear DISL: Disposal EXG: Existing VT: Vinyl Tile
A1.05 Room Plans AGG: Aggregate BSMT: Basement CLR OPG: Clear Opening DIV: Division VTR: Vent Through Roof
S1.01 FOUNDATION Pier beams ALT: Alternate, Alteration; Altitude BT: Bathtub, Bolt CLS: Closure DL: Dead Load VWC: Vinyl Wall Covering
ALUM: Aluminum BTU: British Thermal Units CMT: Ceramic Mosaic Tile DN: Down TSL: Top of Slab
E2.01 SMOKE DETECTOR PLAN & NOTES AMP: Ampere, Ampacity BTUH: British Thermal Units per Hour CMU: Concrete Masonry Unit DP: Dampproofing, Dew Point, Distribution Panel TST: Top of Steel W: West, Width, Wide, Watt, Waste,
S3.01 ROOF - Plans & Details AMT: Amount BVL: Bevelled CND: Condition, Conduit DR: Door, Drain, Dining Room TT: Terrazzo Tile, Traffic Topping Water,
ANCH: Anchor, Anchorage BW: Both Ways CNTR: Center, Counter DRBD: Drainboard TTC: Telephone Terminal Closet W/: With
A2.00 Site Plan APT: Apartment COAX: Coaxial DT: Drain Tile TV: Television W/O: Without
ASC: Above Suspended Ceiling CO: Company, Cleanout, Cased Opening, Cut Out DTL: Detail TW: Top of Wall, Thin Wall (conduit) W&M: Washburn & Moen Gauge
S2.01 Ballon frame Notes ASME: American Society of Mechanical C: Courses, Curb, Channel, Degrees CO & DP: Cleanout & Deck Plate DVTL: Dovetail TW: Top of Wall, Thin Wall (conduit), WAINS: Wainscot
A1.03 Insulation Details Engineers Celsius, COEF: Coefficient DW: Dumbwaiter, Distilled Water TYP: Typical WB: Wood Base
ASPH: Asphalt C/C: Center to Center COL: Column DWGS: Drawings TZ: Terrazzo WC: Watercloset
A3.05 3D View ASTM: American Society for Testing and C TO C: Center to Center COMB: Combination, Combustion DWL: Dowel WD: Wood
A4.02 BlowUp floor Plan Materials CA: Compressed Air COMP: Composition, Compressed DWP: Drywall, Painted WDP: Wood, Painted
AT: Acoustical Tile CAB: Cabinet CONC: Concrete UH: Unit Heater WDSS: Wood, Stained & Sealed
P1.02 Sewage ATC: Acoustical Tile Ceiling CAP: Capacity COND: Condenser, Conduit UL: Underwriters' Laboratories WDW: Window
AVG: Average CARP: Carpenter CONN: Connection E: East, Enamel, Exhaust UNEX: Unexcavated WF: Wide Flange (structural steel)
A0.00 Tittle Sheet
AWS: American Welding Society CAV: Cavity CONST: Construction EB: Expansion Bolt UNEXC: Unexcavated WFS: Water Flow Switch
A1.00 Schedules & Legends CB: Catch Basin, Concrete Block, CONT: Continuous, Continue, Control EC: Exposed Construction UNF: Unfinished WG: Wired Glass
B: Boiler, Bathroom, Bidet CCT: Circuit CONTR: Contractor ECC: Eccentric UNFIN: Unfinished WGL: Wire-Glass
A1.04 Code Compliance B TO B: Back to Back CCW: Counter Clockwise CORR: Corridor, Corrugate EDR: Equivalent Direct Radiation UNO: Unless Noted Otherwise
A2.01 Floor plan B/: Bottom (of) CCTV: Closed Circuit TV CP: Cathodic Protection, Clothes Pole, Cesspool EE: Each End UON: Unless Otherwise Noted WH: Water Heater, Wall Hung, Wall
BAL: Balance, Ballast CD: Cold Drawn, Cadmium CPL: Cement Plaster EF: Each Face UP: Unpainted Hydrant
A2.02 Elevations BD: Board, Blow Down (pipe) CDS: Cold Drawn Steel CS: Countersink, Cast Steel, Cast Stone, EIFS: Exterior Insulation and Finish System UR: Urinal WI: Wrought Iron
A2.03 Roof plan BDY: Boundary CEM: Cement CSMT: Casement EJ: Expansion Joint V: Volt, Valve, Vinyl, Vent, Ventilator WIN: Window
BDRM: Bedroom CEM AB: Cement Asbestos Board CT: Ceramic Tile EL: Elevation, Elevator VA: Volt Ampere WM: Wire Mesh, Water Meter
A3.01 Sections BEL: Below Cem P: Cement Water Paint CTD: Coated ELB: Elbow VAC: Vacuum WP: Waterproof, Working Point,
BETW: Between CER: Ceramic CTR: Center, Counter ELECT: Electrical VACBR: Vacuum Breaker Working
A3.02 Sections BEV: Bevel CF: Cubic Feet CU: Cubic, Coefficient of Utilization ELEV: Elevator, Elevation VAR: Varnish, Varies Pressure, Weatherproof
A5.00 Interior Wall & Details BF: Board Foot CFM: Cubic Feet per Minute CU. FT.: Cubic Feet ELP: Emergency Lighting Panel VAT: Vinyl Asbestos Tile WPR: Waterproofing
BHD: Bulkhead CFS: Cubic Feet per Second CU. YD.: Cubic Yard EMER: Emergency VB: Vapor Barrier, Vacuum Breaker
P1.00 Plumbing Schedule & Details BIT: Bituminous CFT: Cubic Foot CUR: Current ENAM: Enamel VBC: Vinyl Base (Coved) WW: Window Wall
P1.01 Plumbing BKR: Breaker CG: Corner Guard CW: Cold Water ENCL: Enclosure VBS: Vinyl Base (Straight) WWF: Welded Wire Fabric
BL: Base Line, Building Line, Block CHB: Chalk Board CY: Cubic Yard, Cycle ENTR: Entrance VC: Varnished Cambric
E1.00 Electrical Schedules & Details BLDG: Building CHR: Chilled Water Return EP: Electrical Panelboard, Explosion Proof VCP: Vitrified Clay Pipe YD: Yard
BLK: Block CHAM: Chamfer VCT: Vinyl Composition Tile YR: Year
E1.01 Receptacles & Lighting BLT-IN: Built-In CHAN: Channel VENT: Ventilate, Ventilator
S0.00 Structural Schedule & Details BM: Bench Mark CHS: Chilled Water Supply
BMT: Butyl Mastic Tape Sealant

DESCRIPTION OF BUILDING: CONTRACTOR NOTE

808 South Pierce Street, Burnet, TX, 78611 SYMBOLS CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE PROCEEDING WITH WORK. IF ANY No. Description Date
DISCREPANCIES, ERRORS OR OMISSIONS SHOULD BE ENCOUNTERED ON PLANS. CONTRACTOR SHALL NOTIFY ARCHITECT
Existing Wall- to Remain Duct Fitting Rectangular Tee Double Elbow PVC SCH 40 BEFORE ANY PART OF THE WORK IS STARTED SO THAT PROPER CORRECTIONS ARE MADE. IF ARCHITECT IS NOT NOTIFIED
PRIOR TO COMMENCING OF THE WORK. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ANY DISCREPANCIES.
Cap PVC SCH 40
Existing Wall- to be Demolish
Duct Fitting Rectangular Elbow ERRORS AND/OR OMISSIONS.
APPLICABLE CODES New Wall- Concrete Wall 6" or 8" Reducing Coupling PVC SCH 40
Duct Fitting Cap * ALL DESIGNS AND DRAWINGS HEREIN AND PRINTS ISSUED BY THE ARCHITECT ARE THE PROPERTY OF THE ARCHITECT AND
Applicable Codes include, but are not limited to: New Wall- GypsumBoard with Studs
Cross PVC SCH 40
SHALL NOT BE REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE EXPRESSLY DESIGNED.
Duct Fitting Rectangular Transition
Elbow PVC SCH 40
New Wall- CMU Blocks
* IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE CONSENT OF THE ARCHITECT. THE PERSON SO
Tee PVC SCH 40
AHU - Air Handing Unit DOING WILL BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
Door Wye 45 Degree Bend PVC SCH 40
Exhaust Fan * CONTRACTOR SHALL NOT USE FOR CONSTRUCTION PURPOSES ANY DRAWINGS THAT WERE ADVANCED TO HIM PRIOR TO THE
Toilets
Wye Combination Bend PVC SCH 40 START OF CONSTRUCTION. ALL PLANS BEING USED BY CONTRACTOR SHOULD BEAR A STAMP WITH THE LABEL: "FOR
Windows
GENERAL Mark
Recessed mounted Ceiling Light Fixture
CONSTRUCTION ONLY" SIGNED BY ARCHITECT.
Jaime Corts
1 Windows Tags Sink Mount * GENERAL CONTRACTOR SHALL FIELD SURVEY LOCATION AND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO
Zoning District Mark Wall mounted Light Fixture, mounting
height as indicated
CONSTRUCTION. ANY DISCREPANCES SHALL BE REPORTED TO THE TENANT AND ARCHITECT
Lot Area 101 Door Tags
Shower Tub 30" x 60" Mark 2016-12-08-01 Jaime Corts
CB Switches - circuit base * GENERAL CONTRACTOR SHALL COMPLETE ALL WORK AS INDICATED ON THESE PLANS UNLESS OTHERWISE NOTED.
Allowable Building Area Mark
Switches- Dimmer - mounted at 48" AFF.
1 Revision Tag 808 South Pierce Street, Burnet, TX, 78611
Proposed Building Area
D
Vanity * GENERAL CONTRACTOR SHALL OBTAIN PERMITS, APPROVALS, INSPECTIONS, CERTIFICATE FOR COMPLIANCE AND
Mark
DR Switches- Door - mounted at 48" AFF. CERTIFICATE OF OCCUPANCY AS REQUIRED, UNLESS OTHERWISE NOTED.
?R @ ? Stair Tag
BUILDING HEIGHT Washer & Dryer Combo - N.I.C. Mark
4 Switches- four Way- mounted at 48" AFF. * GENERAL CONTRACTOR SHALL CHECK IN WITH AND COORDINATE ALL WORK WITH THE LANDLORD'S PROJECT PERSONNEL. Tittle Sheet
Room Name Mark

Building Area 101 Room Tag With Area


SP Switches- Pole - mounted at 48" AFF. * GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER, LIGHT AND TELEPHONE IN ACCORDANCE WITH LANDLORD'S AND
TENANTS REQUIREMENTS.
Mark
150 sf 3 Switches- Three Way
* GENERAL CONTRACTOR SHALL REMOVED ALL THESE ITEMS AT THE COMPLETION OF WORK OR AS REQUIRED.
SETBACK REQUIREMENTS Mark
T Switches- Timer
NOT FOR CONSTRUCTION
* GENERAL CONTRACTOR SHALL HAVE TENANT'S SPACE CLEANED UPON COMPLETION OF WORK BY A PROFFESSIONAL
Front 101 Detail Number Recessed or surface mounted Electrical
Panel CLEANNING SERVICE.
Side Interior Single Receptacle -120 volt, 1 Phase, 3 Wire Project Number
* GENERAL CONTRACTOR SHALL MAINTAIN ON SITE AT ALL TIMES, ALL APPROVED DRAWINGS INCLUDING ALL REVISIONS AND
Side Street Wall mounted at 18" AFF
ADDENDA.
2016-12-08-01
Duplex Receptacle -120 volt, 1 Phase, 3 Date
Rear 1 Wire Wall mounted at 18" AFF Issue Date

A0.00
Section Head - Filled Single Receptacle -240 volt, 1 Phase, 4 * GENERAL CONTRACTOR SHALL HAVE AT ALL TIME IN SITE OFFICE COPY OF ALL ENDORSEMENTS AND PERMITS OF THE
A1 Drawn By
OCCUPANCY GROUP Wire Wall, mounted at 18" AFF
Duplex Receptacle - Ground Fault -120 volt, 1
PROJECT AT A VISIBLE PLACE. Author

1
GFCI
Phase, 3 Wire Wall mounted at 18" AFF
Checked By
Checker
Occupancy Group A1
Callout Head
WP Duplex Receptacle - Water Proof -120 volt, 1 Scale
DRWNG. NO.
Phase, 3 Wire Wall mounted at 18" AFF
As indicated

06/04/2017 1:23:54 p. m.
Room Schedule Room Schedule
Number Name Area Level Number Name Area Level

4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013


First Floor 87 Patio 168 SF First Floor
Telephone (786) 502-4836
77 Masterbedroom 175 SF First Floor 88 Porche 100 SF First Floor email customerservice@sdp-us.com
78 Master 78 SF First Floor 89 CL 18 SF First Floor
Bathroom 90 Pantry 7 SF First Floor
79 WIC 50 SF First Floor 91 CL 5 SF First Floor
80 Dinning 157 SF First Floor 92 CL 5 SF First Floor
81 Garage 362 SF First Floor 93 CL 22 SF First Floor
82 Laundry 252 SF First Floor 94 CL 22 SF First Floor
83 Bedroom 3 98 SF First Floor 95 Linen 6 SF First Floor
Area Schedule (Gross Building) 84 Bedroom 2 136 SF First Floor 96 Living 181 SF First Floor
85 Bathroom 57 SF First Floor 98 Hall 147 SF First Floor
Name Area
86 Bedroom 1 127 SF First Floor Grand total: 21 2171 SF
Gross Building Area 2395 SF

IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE


CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
EXPRESSLY DESIGNED.

Patio
rea comn del edificio 87
168 SF

Bedroom 1 Bathroom
Masterbedroom Dinning 86
77 80
Bedroom 1
127 SF
175 SF 157 SF
Bedroom 2
Living CL Bedroom 3
96 94

181 SF 22 SF CL

Master Bathroom Bathroom Dinning


78 85
Kitchen Garage
78 SF 57 SF
97 Linen
Redundant
Room 95 Hall
Hall CL
6 SF
WIC REF.
98 93 Kitchen
79 147 SF 22 SF
W D
Pantry Laundry
50 SF Laundry 90
CL CL
82 7 SF Bedroom 3 Bedroom 2 Linen
92 91
252 SF
83 84 No. Description Date
CL
136 SF
Living
5 SF 5 SF 98 SF
89
18 SF Master Bathroom
Porche
88 Masterbedroom
100 SF
Pantry
Patio
Porche
Jaime Corts
WIC
2016-12-08-01 Jaime Corts
808 South Pierce Street, Burnet, TX, 78611

Room Plans

First Floor First Floor - Room


1 2
3/16" = 1'-0" 3/16" = 1'-0"
NOT FOR CONSTRUCTION

Project Number
2016-12-08-01
Date
Issue Date
Drawn By

Checked By
Author A1.05
Checker
DRWNG. NO.
Scale
3/16" = 1'-0"

06/04/2017 1:23:57 p. m.
78' - 0"

5' - 1" 2' - 5" 53' - 5" 17' - 1"

4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013


Telephone (786) 502-4836

10' - 6"

10' - 6"
email customerservice@sdp-us.com

2' - 0"

2' - 0"
North

IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE


CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
EXPRESSLY DESIGNED.

37' - 5"
52' - 5"
90' - 0"

90' - 0"
2' - 5"
No. Description Date
2' - 5"

37' - 8"
22' - 8"

Jaime Corts

2016-12-08-01 Jaime Corts


808 South Pierce Street, Burnet, TX, 78611
5' - 1" 2' - 5" 19' - 6" 2' - 7 5/8" 7' - 0 1/2" 2' - 7 3/4" 7' - 9 1/4" 2' - 7 3/4" 11' - 2 1/8" 17' - 1"

Site Plan

78' - 0"

NOT FOR CONSTRUCTION

Project Number
2016-12-08-01
Date
Issue Date

1
Site
Drawn By

Checked By
Author A2.00
3/16" = 1'-0" Checker
DRWNG. NO.
Scale
3/16" = 1'-0"

06/04/2017 1:23:58 p. m.
A2.02
1 2 4 1
A3.01 A3.02 2 A3.02 A3.02

4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013


Telephone (786) 502-4836
email customerservice@sdp-us.com
51' - 9"

27' - 1" 11' - 11" 12' - 9"

9' - 1"

9' - 1"
13' - 6" 11' - 11 1/4" 12' - 0" 11' - 6 3/4"

4' - 2"
14 14 14 14

Patio
13' - 6" 11' - 11 1/4"
87

5' - 0 1/8"
141
North
14
Bedroom 1
IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
86

10' - 0 1/2"
CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
Masterbedroom Dinning BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
14 OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
77 80
b

13' - 1 3/4"

13' - 1 3/4"

13' - 4 1/2"
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE

13' - 2"
EXPRESSLY DESIGNED.

b
136

13' - 7 1/8"
2' - 3 1/2" 27' - 4" 3' - 4 1/4" 7' - 10"

2' - 9"
2' - 6"
15' - 8 1/4"
139 b

135
b

b
5' - 8 1/2"

4' - 10 1/8"
4

5' - 6 1/4"
24 Bathroom

b
6' - 0"

6' - 0"
1 85 5
10 A4.01

8' - 3 3/4"
2 134 2

b
4

b
A3.01 8 9 A3.01

3' - 0"
A4.01 6

12' - 3 3/4"
12' - 1 1/4"
7
Master Bathroom 4
3' - 11 3/4"

3' - 11 3/4"

3' - 3"
3' - 0" 3' - 0" 3' - 8 5/8"

2' - 5"
78 138
3 A4.02 5 1 A2.02
A2.02 4
140 132
2

2' - 9"
b
8' - 7 1/2" 2' - 6" 9' - 8" 7' - 0 1/4" 3' - 4 1/4" 7' - 10"
4 4

6' - 10 1/2"

b
A3.01 9' - 3 3/4" A3.01
52' - 6"

52' - 6"
5' - 9 1/2"

5' - 9 1/2"

133

2' - 9"
WIC 131 7' - 10"
146
b b
79

b
b
Laundry
82

10' - 10 1/2"

10' - 10 1/2"
3 3
A3.01 2' - 0" 2' - 0" 142 Bedroom 2 A3.01

10' - 2"
Bedroom 3 14
149 84
152

6' - 10 7/8"
127 83
b 147

3 11' - 6 3/4" 3
A3.02
9' - 8"
A3.02 No. Description Date
Garage
81 Porche
14 14
88
22' - 0 3/4"

22' - 0 3/4"

18' - 3 3/4" 12' - 11" 6' - 7" 12' - 9"


19' - 1 1/2"

15' - 1"

15' - 1"
b

Jaime Corts

2016-12-08-01 Jaime Corts


808 South Pierce Street, Burnet, TX, 78611
144

19.50 32' - 3" Floor plan


51' - 9"

NOT FOR CONSTRUCTION

3
Project Number
1 2 4 1 2016-12-08-01
A2.02
A3.01 A3.02 A3.02 A3.02 Date
Issue Date

1 First Floor
Drawn By

Checked By
Author A2.01
A2.01 1/4" = 1'-0" Checker
DRWNG. NO.
Scale
1/4" = 1'-0"

06/04/2017 1:23:58 p. m.
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
Telephone (786) 502-4836
email customerservice@sdp-us.com

56' - 0 1/8"

25' - 8 3/8" 9' - 9 5/8" 20' - 6 1/8"


55' - 0 1/4"

Roof Plan Roof Plan


20' - 8 1/2" 1' - 3 1/8" 12' - 5" 41' - 4 1/8" 20' - 8 1/2"
IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
" 3 3/
1'-0 8" / ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
8" / 1'-0 " OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
3 3/ " 1'-0 REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
"/ 31
3/8
EXPRESSLY DESIGNED.
/ 2"

7' - 3 1/8"

7' - 3 1/8"
3
6' - 11"

/1
7" / 1'-0"

'-0
"

Roof Roof
10' - 0" 10' - 0"
18' - 10 1/8"

18' - 9 1/8"

18' - 9 1/8"

18' - 9 1/8"
10' - 5 1/8"

10' - 0"

10' - 0"
3' - 4"

3' - 4"
First Floor First Floor

3' - 0"

3' - 0"
1' - 6"

1' - 6"

1' - 6"
0' - 0" 0' - 0"
T.O Foundation Earth Earth
-2' - 6" -1' - 6" -1' - 6"

1 East
A2.02 3/16" = 1'-0"
2 North
A2.02 3/16" = 1'-0"

No. Description Date

7' - 9 1/4" 56' - 0 1/8"


55' - 0 1/8"
9' - 4 3/8" 18' - 11" 35' - 6"
2' - 0" 9' - 10 3/8" 29' - 5 3/4" 12' - 5" 1' - 3 1/8"

Roof Plan
Roof Plan 20' - 8 1/2"
20' - 8 1/2"

"
4 5/8"

1'-0
2" /
3 1/
3' - 3 1/4"

0" 33

7" / 1'-0"
1'- /8 "

7" / 1'-0"

7' - 4 1/8"
/ 7" / 1'
7"
4" / 1'-0"

/1 -0"
'-0
"
Jaime Corts
4' - 0"

22' - 2 1/2"
Roof 2016-12-08-01 Jaime Corts
17' - 3 1/8"

Roof 10' - 0"


18' - 9 1/8"

10' - 0"
17' - 11 1/4"
18' - 3 7/8"

808 South Pierce Street, Burnet, TX, 78611

10' - 0"
10' - 0"

Elevations

First Floor
3' - 4"

First Floor
1' - 0 3/4"
3' - 0"

1' - 6"

1' - 6"
0' - 0"
0' - 0"
Earth
T.O Foundation NOT FOR CONSTRUCTION
-1'
-2' -- 6"
6"

Project Number
2016-12-08-01
Date
Issue Date
3
A2.02
South
3/16" = 1'-0"
4
A2.02
West
3/16" = 1'-0"
Drawn By

Checked By
Author A2.02
Checker
DRWNG. NO.
Scale
3/16" = 1'-0"

06/04/2017 1:24:00 p. m.
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
Telephone (786) 502-4836
email customerservice@sdp-us.com
55' - 0 1/4"

7' - 9 1/4"
29' - 1 1/8" 11' - 11" 14' - 0 1/8"

IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE


CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT

31
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE

"
/ 2"
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE

'-0
EXPRESSLY DESIGNED.

20' - 6 1/8"

/1
/1
'-0

/8 "
"

33
4" / 1'-0"

41' - 0 1/8"
6" / 1'-0"

7" / 1'-0"
56' - 0 1/8"

REF.

W D

31

33
4" / 1'-0"

/8 "
/ 2"

/1
/1

'-0
'-0

"
"

"
'-0

31
/1

/ 2"
/2"
31

/1
35' - 6"

'-0
"
7" / 1'-0"
7" / 1'-0"

14' - 11 7/8"
No. Description Date

11' - 10 1/2" 11' - 10 1/2" 7' - 10 1/4" 6' - 1 1/2" 6' - 1 1/2" 11' - 2 1/8"

55' - 0 1/4"

Jaime Corts

2016-12-08-01 Jaime Corts


808 South Pierce Street, Burnet, TX, 78611

Roof Plan
1
3/16" = 1'-0" Roof plan

NOT FOR CONSTRUCTION

Project Number
2016-12-08-01
Date
Issue Date
Drawn By

Checked By
Author A2.03
Checker
DRWNG. NO.
Scale
3/16" = 1'-0"

06/04/2017 1:24:01 p. m.
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
Telephone (786) 502-4836
email customerservice@sdp-us.com

55' - 0 1/4" Roof Plan


Roof Plan 20' - 8 1/2"
1' - 3" 41' - 10 3/4" 9' - 10 3/8" 2' - 0 1/8" 20' - 8 1/2"

7"
/1
'-0
0" "
/ 1'-
7' - 4"

7"

Roof

22' - 2 1/2"
Roof 10' - 0"
10' - 0"
18' - 10 1/8"

IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE


CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
10' - 0"

10' - 0"
EXPRESSLY DESIGNED.

T e
p y
iC
n
to
c 7
0
t2
h
rig

First Floor
0' - 0" First Floor
0' - 0"
1' - 6"

1' - 6"
Earth T.O Foundation
-1' - 6" Earth
-2' --1'
6"- 6"
T.O Foundation
-2' - 6"

3 Section 2 1 Section 7
A3.01 3/16" = 1'-0" A3.01 3/16" = 1'-0"

No. Description Date

55' - 0 1/4"
55' - 0 1/4"
2' - 0 1/8" 39' - 4" 12' - 5" 1' - 3 1/8"

1' - 3 1/8" 51' - 9" 2' - 0 1/8"


Roof Plan Roof Plan
20' - 8 1/2" 20' - 8 1/2"
10' - 8 1/2"

10' - 8 1/2"
0" 7"
/ 1'- 33
/8 "
/1
'-0
7" / 1' "
-0"
Jaime Corts
7' - 3"

2016-12-08-01 Jaime Corts


22' - 2 1/2"

22' - 2 1/2"
1' - 0 1/8"

Roof Roof
10' - 0" 10' - 0"
18' - 9 1/8"

808 South Pierce Street, Burnet, TX, 78611


10' - 0"

10' - 0"
9' - 0"

Sections

First Floor First Floor


1' - 6"

1' - 6"

1' - 6"
0' - 0" 0' - 0"
NOT FOR CONSTRUCTION
T.O Foundation T.O Foundation
Earth
Earth
-2' - 6" -2'
-1' - 6" -1' -- 6"
6"
Project Number
2016-12-08-01
Date
Issue Date

4
A3.01
Section 5
3/16" = 1'-0" A3.01
2 Section 3
3/16" = 1'-0"
Drawn By

Checked By
Author A3.01
Checker
DRWNG. NO.
Scale
3/16" = 1'-0"

06/04/2017 1:24:04 p. m.
55' - 0 1/4"
37' - 5" 2' - 0 1/8"
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
1' - 3 1/8" 16' - 0 1/2" 25' - 10 1/4" 9' - 10 3/8" 2' - 0 1/8"
Telephone (786) 502-4836
email customerservice@sdp-us.com

" 7"
'-0

7' - 4 1/8"
/1
/1 '-0

6' - 10"

6' - 10"
7" 7" "

7' - 10"
1'-0
" 0" /1
4" /
4" /
1 '-0" / 1'- '-0
"
7"

5' - 0"
Roof Roof
10' - 0" 10' - 0"

18' - 10 1/8"
10' - 0"

10' - 0"
10' - 6"
IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
First Floor First Floor CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.

1' - 6"

1' - 6"
0' - 0" 0' - 0" ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE

1' - 0"
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
T.O Foundation Earth T.O Foundation Earth
EXPRESSLY DESIGNED.

-2' - 6" -1' - 6" -2' - 6" -1' - 6"

3 Section 8
A3.02 3/16" = 1'-0"

1 Section 6
A3.02 3/16" = 1'-0"

63' - 9 3/8"

35' - 6" 18' - 11" 9' - 4 3/8"

Roof Plan
20' - 8 1/2"
3' - 4 3/8"

" 3 3/
1'-0 8" /
8" / 1'-0

10' - 8 1/2"
3 3/ "
6' - 11"

7" / 1'-0"
22' - 2 1/2"

22' - 2 1/2"
Roof
3' - 6 1/2"

10' - 0"

10' - 0"
6' - 10 5/8"

First Floor
1' - 6"

1' - 6"
0' - 0"
T.O Foundation Earth
-2' - 6" -1' - 6" No. Description Date
4 Section 9
A3.02 3/16" = 1'-0"

56' - 0 1/8"

35' - 6" 0" 20' - 6 1/8"


Roof Plan
20' - 8 1/2"
1"

" 4" /
1'-0 1 '-0"
4" /
6' - 10"

Jaime Corts

7' - 3"
7" / 1'-0"

2016-12-08-01 Jaime Corts


5 1/8"

1' - 0 1/8"
Roof
10' - 0"
18' - 9 1/8"

18' - 9 1/8"
808 South Pierce Street, Burnet, TX, 78611
10' - 0"

Sections

10' - 6"
First Floor
1' - 6"

0' - 0"
NOT FOR CONSTRUCTION
T.O Foundation Earth
-2' - 6" -1' - 6"
Project Number
2016-12-08-01
Date
2 Section 1 Issue Date

A3.02
A3.02 3/16" = 1'-0"
Drawn By
Author
Checked By
Checker
DRWNG. NO.
Scale
3/16" = 1'-0"

06/04/2017 1:24:06 p. m.
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
Telephone (786) 502-4836
email customerservice@sdp-us.com

IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE


CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
EXPRESSLY DESIGNED.

No. Description Date

Jaime Corts

2016-12-08-01 Jaime Corts


3D View - Front
1
808 South Pierce Street, Burnet, TX, 78611

3D View

NOT FOR CONSTRUCTION

Project Number
2016-12-08-01
Date
Issue Date
Drawn By

Checked By
Author A3.05
Checker
DRWNG. NO.
Scale

06/04/2017 1:24:10 p. m.
9' - 7 1/8"
A-2 P-4
7 1/8" 2' - 6" 4 3/4" 2' - 10" 2' - 10 3/4" 4 1/2"
8' - 9 5/8"
4 1/2"9 1/2" 2' - 1 3/8" 2' - 9 1/8" 2' - 1 7/8" 7 1/8" 1' - 9 3/4" 1' - 8 1/4" 2' - 10" 1' - 11 1/8" 11 5/8"4 1/2"
4 1/2" 1' - 10 1/4" 3' - 9 7/8" 2' - 1 7/8" 7 1/8"

4 1/2"
4 1/2"

4 1/2"

1' - 11 3/4"
1' - 2 7/8"
1' - 5" 4 1/2"

1 3/8"

3' - 0"
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013

2' - 4 1/8"
Telephone (786) 502-4836

2' - 5 1/8"

5' - 3 1/4"
P-6 P-5 email customerservice@sdp-us.com
A-1

4' - 10 1/8"

6' - 0"
A-3

3' - 11 1/4"
A-5

3' - 3"
6' - 0"
2' - 6"
9' - 0"

9' - 0"
9' - 0 3/4"
3' - 3 1/4"
5' - 7 7/8"

9' - 11 3/8"

9' - 9 1/8"
A-1 A-1

9 1/4"
A-4

4 1/2"
1' - 11 7/8" 4 1/2"
A-4 A-1

2' - 11 7/8"

3' - 9 1/4"
P-5

2' - 11 5/8"
P-6

3' - 0"
A-2

3' - 11 3/4"
2' - 6"

3' - 2 3/8"
IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL

4 1/2" 1' - 3"


P-4 BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.

2' - 4 1/2"
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT

1' - 9 3/8"
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE

4 1/2"
10 3/8" 1' - 11 3/4" 1' - 5 3/4" 1' - 4 1/4" 2' - 1 7/8" 7 1/8" EXPRESSLY DESIGNED.
2' - 4 1/8" 11 1/8" 2' - 9 3/8" 2' - 11 1/2" 3 5/8"
4 1/2" 2' - 5 1/2" 4 1/2" 2' - 5 7/8" 2' - 6 1/4" 7 1/8" 8' - 5 1/8"

4 1/2"

4 1/2"
9' - 3 5/8"
4 1/2" 2' - 5 1/2" 4 1/2" 5' - 0" 7 1/8"
P-4 7 1/8" 1' - 3" 1' - 3" 4 3/4" 2' - 10" 1' - 6 3/4" 1' - 4" 4 1/2" Bath 2 - P-4
Elevation 3
8' - 9 5/8" 7
7 1/8" 2' - 10 3/4" 2' - 10" 2' - 10 3/4" 4 1/2"
1/2" = 1'-0"

First Floor - Bathroom Bath 1 - Elevation 3 9' - 7 1/8"


2 4
1/2" = 1'-0" 1/2" = 1'-0"
9' - 0 3/4" First Floor - Bathroom 2
3
1/2" = 1'-0"
4 1/2" 1' - 10 1/4"
3 5/8" 6 3/8" 2' - 11 1/2" 2' - 8 1/8" 4 1/2"
1' - 11 7/8"

1' - 11 7/8"

1' - 10 1/4" 3 3/4"


1' - 11 3/4"
5' - 3 1/4"
1' - 0 1/8"

A-4
2' - 11 1/2"

5' - 3 1/4"
1' - 11 3/8"

9' - 0"
A-3
5' - 7"

2' - 10"
3' - 3"
9' - 0"

A-1

9 1/4"

9' - 0"

9' - 0"

9' - 0"
A-5
2' - 11 1/8"

A-1

8 3/4"
2' - 11 5/8"
P-6
4' - 0 5/8"

2' - 9"
A-2

3' - 9 1/4"
P-5
P-4
1' - 1 1/2"

3' - 0"
P-5
4 1/2" 2' - 6" 6 1/4" 3' - 2" 7 1/4" 1' - 6 1/4" 4 1/2"

1' - 3"
9' - 0 3/4" P-5
A-2

4 1/2" 2' - 0" 1' - 11 7/8" 4 1/2" 2' - 6" 2' - 4 1/8" 4 1/4" 5' - 9 3/8" 9" 1' - 3" 1' - 4 7/8" No. Description Date
9' - 2 3/8"
Bath 1 - Elevation 1 Bath 1 - Elevation 4 9' - 11 1/8"
5 10 A-2
1/2" = 1'-0" 1/2" = 1'-0" P-4
Bath 2 - Elevation 2 Bath 2 - Elevation 4
8 9
1/2" = 1'-0" 1/2" = 1'-0"
9' - 7 1/8"

7 7/8" 2' - 5 1/4" 4 3/4" 2' - 10" 10 3/4" 2' - 0" 4 1/2"
2' - 2"

5' - 3 1/2"

22 40 00 - Plumbing Fixture Schedule Copy 1


Jaime Corts
7' - 9"

A-3 HW CW Plumbing
Mark Count Family Connection Connection Type Comments Faucet Category
9' - 0"

9' - 0"

2016-12-08-01 Jaime Corts


9' - 0"

2 BathTub-Rectangular-RR01 Plumbing
6' - 10"

Fixture
A-5 808 South Pierce Street, Burnet, TX, 78611
A-1 2 CADET Toilet FloWise
8 1/2"

2 Faucet-Lavatory-Brizo-Tresa-65836LF
93 1 Faucet-Lavatory-Kohler-Refinia-(5317-4)
2 Faucet_Wall-Zurn-Z1341XL-C12-Lead-Free 1/2 Female Solder x
BlowUp floor Plan
3/4 Male Solder Inlet
1' - 3"

3' - 0"

114 1 Floor Drain - Round


96 1 M_Fregadero de cocina-Simple
P-5 117 1 Mirror-Kohler-Evandale-2746
5' - 0 1/4" 2' - 9 7/8" 4 1/2" 3' - 4 1/4" NOT FOR CONSTRUCTION
11' - 6 3/4" 109 1 Shower-Faucet_Trim-DELTA-Vero-T17253-H2
92 1 Sink-One_Piece-Kohler-Tresham-2979_8
91 1 Vanity-Petite-Kohler-Tresham-2604- RR01 Plumbing Project Number
P-5
Fixture 2016-12-08-01
Date
Grand total: 15 Issue Date
Bath 1 - Elevation 2 Bath 2 - Elevation 1
6
1/2" = 1'-0"
1
1/2" = 1'-0" Drawn By

Checked By
Author A4.01
Checker
DRWNG. NO.
Scale
1/2" = 1'-0"

06/04/2017 1:24:14 p. m.
STRUCTURAL - GENERAL NOTES
TABLE 2304.9.1 FASTENING SCHEDULE
APPLICABLE CODES AND STANDARDS 3. WHERE DIMENSIONS ARE PROVIDED FOR OPENINGS, BLOCKOUTS, FLOOR DEPRESSIONS,CURBS,
ETC., BUT MAY BE AFFECTED BY THE EQUIPMENT PURCHASED, THE CONTRACTOR SHALL VERIFY THE
GOVERNING CODES: INFORMATION PROVIDED PRIOR TO CONSTRUCTION. CONNECTION FASTENING LOCATION
ALL DESIGN AND CONSTRUCTION IS BASED ON AND SHALL BE IN ACCORDANCE WITH THE INTERNATIONAL
BUILDING CODE, 2012 EDITION, ALL REFERENCED STANDARDS SHALL BE OF THE EFFECTIVE DATE NOTED IN THE 4. PROVIDE CONCRETE EQUIPMENT PADS AND INERTIAL BASES FOR MECHANICAL AND
CONTROLLING BUILDING CODE. ELECTRICAL INSTALLATIONS. CONSTRUCT PADS AND BASES IN ACCORDANCE WITH THE 1. Joist to sill or girder 3 - 8d common (21/2 0.131) 30. Ledger strip 3 - 16d common (31/2 0.162 ) face nail at each joist
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318) TYPICAL DETAILS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR LIMITS AND 3 - 3 0.131 nails toenail 4 - 3 0.131 nails
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) LOCATIONS. 3 - 3 14 gage staples 4 - 3 14 gage staples 4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
AMERICAN WELDING SOCIETY (AWS) D1.1, D1.3, D1.4
2 - 8d common (21/2 0.131) toenail each end Telephone (786) 502-4836
MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7-05) 5. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS. 2. Bridging to joist 31. Wood structural panels and particleboardb 1/2 and less6dc, 1
2 - 3 0.131 nails email customerservice@sdp-us.com
STEEL DECK INSTITUTE SPECIFICATIONS AND LOAD TABLES CHECK AND VERIFY EXISTING DIMENSIONS AND TAKE ADDITIONAL MEASUREMENTS AS NEEDED. NOTIFY Subfloor, roof and wall sheathing (to framing) 2 3/8 0.113 nail (n)
ASTM MATERIAL STANDARDS AS NOTED ARCHITECT OF ANY DISCREPANCY BETWEEN ACTUAL CONDITIONS AND INDICATED CONDITIONS. 2 - 3 14 gage staples 13/4 16 gage (o)
AISI SPECIFICATIONS FOR DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF 19/32 to3/4 8ddor 6de
PCI DESIGN HANDBOOK (MNL 120) THE ARCHITECT OR STRUCTURAL ENGINEER. 3. 1 6 subfloor or less to each joist 2 - 8d common (21/2 0.131) face nail 23/8 0.113 nailp
2 16 gagep
6. CONTRACTOR SHALL PROVIDE AND BE RESPONSIBLE FOR THE PROTECTION AND REPAIR OF ADJACENT 4. Wider than 1 6 subfloor to each joist 3 - 8d common (21/2 0.131) face nail 8dc
DESIGN LOADS EXISTING SURFACES AND AREAS WHICH MAY BE DAMAGED BY NEW WORK. 7/8 to 1 10ddor 8de
5. 2"subfloor to joist or girder 2 - 16d common (31/2 0.162) blind and face nail 11/8 to 11/4
1) DEAD LOAD ACTUAL WEIGHT OF MATERIALS USED ADDING THE FOLLOWING: 7. ALL COLUMNS AND FOUNDATIONS, UNLESS NOTED OTHERWISE, SHALL BE CENTERED ON GRIDLINES IN Single floor (combination subfloor-underlayment 3/4 and less6de
EACH DIRECTION. BEAMS SHALL BE EQUALLY SPACED BETWEEN COLUMN CENTERLINES UNLESS NOTED 6. Sole plate to joist or blocking 16d (31/2 0.135) at 16 o.c. to framing) 7/8 to 1 8de
ALLOWANCE FOR CEILINGS, LIGHTING, PLUMBING, OTHERWISE. 3 0.131 nails at 8 o.c. typical face nail 11/8 to 11/4 10ddor 8de
3 14 gage staples at 12 o.c.
FIRE PROTECTION AND HVAC 10 PSF 8. TYPICAL DETAILS SHALL APPLY IN GENERAL CONSTRUCTION UNLESS SPECIFICALLY DETAILED. WHERE Sole plate to joist or blocking at braced 3 - 16d (31/2 0.135) at 16 o.c. braced wall panels 1/2 or less 6df
ALLOWANCE FOR ROOFING SYSTEM 20 PSF NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. 4 - 3" 0.131 nails at 16" o.c. 5/8 8df
wall panel 4 - 3" 14 gage staples at 16" o.c. 32. Panel siding (to framing)
2) LIVE LOAD 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION OF ALL
FORMS, SHORING AND TEMPORARY BRACING. THE CONTRACTOR SHALL PROVIDE ALL MEASURES 7. Top plate to stud 2 - 16d common (31/2 0.162) 1/2 No. 11 gage roofing nailh
AREA OF BUILDING DESIGN LIVE LOAD NECESSARY TO PROTECT THE STRUCTURE AND SAFETY OF WORKMEN DURING CONSTRUCTION. 3 - 3 0.131 nails end nail 6d common nail (2 0.113 )
3 - 3 14 gage staples 33. Fiberboard sheathingg No. 16 gage staplei
PATIENT ROOMS 50 PSF A. DO NOT PLACE CONSTRUCTION MATERIALS OR OTHER CONSTRUCTION LOADS ON 8. Stud to sole plate 25/32 No. 11 gage roofing nailh
PARTITIONS 15 PSF THE STRUCTURE SUCH THAT THE LOADS PLACED EXCEED THE CAPACITY OF THE STRUCTURE. 4 - 8d common (21/2 0.131) 8d common nail (21/2 0.131 )
IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
MECHANICAL SPACES 150 PSF 4 - 3 0.131nails toenail No. 16 gage staplei BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
STAIRS 100 PSF B. TAKE INTO CONSIDERATION THAT FULL STRUCTURAL CAPACITY OF MANY STRUCTURAL MEMBERS IS 3 - 3 14 gage staples ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
CORRIDORS ABOVE FIRST FLOOR 80 PSF NOT REALIZED UNTIL STRUCTURAL ASSEMBLY IS COMPLETE; THAT IS, UNTIL SLABS, DECKS, DIAGONAL REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
BRACING AND SHEAR WALLS ARE INSTALLED. 2 - 16d common (31/2 0.162) 34. Interior paneling 1/4 4dj
EXPRESSLY DESIGNED.

3) WIND LOAD 3 - 3 0.131 nails end nail 3/8 6dk


C. PROVIDE TEMPORARY BRACING AND GUYING TO PROVIDE STABILITY AND RESIST ALL LOADS TO WHICH 3 - 3 14 gage staples
BASIC WIND VELOCITY = 105 MPH THE PARTIALLY COMPLETED STRUCTURE MAY BE SUBJECTED INCLUDING ERECTION EQUIPMENT AND ITS
IMPORTANCE FACTOR = 1.15 OPERATION. ADEQUACY OF TEMPORARY BRACING AND GUYING FOR THIS PURPOSE IS THE SOLE 16d (31/2 0.135) at 24 o.c. face nail
EXPOSURE CATEGORY = C RESPONSIBILITY OF THE CONTRACTOR. 3 0.131 nail at 8 o.c. For SI: 1 inch = 25.4 mm.
INTERNAL PRESSURE COEFFICIENT = +/-0.18 9. Double studs 3" 14 gage staple at 8" o.c.
16d (31/2 0.135 at 16 o.c. a. Common or box nails are permitted to be used except where otherwise stated.
4) SEISMIC LOAD b. Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports except 6 inches at supports
3 0.131 nail at 12 o.c. typical face nail where spans are 48 inches or more. For nailing of wood structural panel and particleboard diaphragms and shear
IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. 10. Double top plates 3" 14 gage staple at 12" o.c. walls, refer to Section 2305. Nails for wall sheathing are permitted to be common, box or casing.
OCCUPANCY CATAGORY: III 8 - 16d common (31/2 0.162) c. Common or deformed shank (6d - 2 0.113 ; 8d - 21/2 0.131 ; 10d - 3 0.148 ).
IMPORTANCE FACTOR: 1.25 d. Common (6d - 2 0.113 ; 8d - 21/2 0.131 ; 10d - 3 0.148 ).
SPECTRAL RESPONSE COEFFICIENTS: 12 - 3 0.131 nails e. Deformed shank (6d - 2 0.113 ; 8d - 21/2 0.131 ; 10d - 3 0.148 ).
TABLE 2304.6 MINIMUM THICKNESS OF WALL SHEATHING 12 - 3 14 gage staples lap splice
Ss = 24.0% Double top plates f. Corrosion-resistant siding (6d - 17/8 0.106 ; 8d - 23/8 0.128 ) or casing (6d - 2 0.099 ; 8d -
S1 = 6.0% 21/2 0.113 ) nail.
SHEATHING TYPE MINIMUM THICKNESS MAXIMUM WALL STUD SPACING
SDs = .192 g. Fasteners spaced 3 inches on center at exterior edges and 6 inches on center at intermediate supports, when
SD1 = .068 used as structural sheathing. Spacing shall be 6 inches on center on the edges and 12 inches on center at
Wood boards 5/8 inch 24 inches on center
SITE CLASS: C intermediate supports for nonstructural applications.
SEISMIC DESIGN CATEGORY: B 11. Blocking between joists or rafters to top h. Corrosion-resistant roofing nails with 7/16-inch-diameter head and 11/2-inch length for 1/2-inch sheathing and
Fiberboard 1/2 inch 16 inches on center 3 - 8d common (21/2 0.131) toenail
ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE plate 13/4-inch length for 25/32-inch sheathing.
RESPONSE MODIFICATION FACTOR R = 4 3 - 3 0.131 nails i. Corrosion-resistant staples with nominal 7/16-inch crown or 1-inch crown and 11/4-inch length for 1/2-inch
Wood structural panel In accordance with Tables 2308.9.3(2) 3 - 3 14 gage staples
SEISMIC RESPONSE COEFFICIENT Cs = .06 sheathing and 11/2-inch length for 25/32-inch sheathing. Panel supports at 16 inches (20 inches if strength axis in
M-S "Exterior Glue" and and 2308.9.3(3)
BASIC SEISMIC FORCE RESISTANCE SYSTEM: INTERMEDIATE PRECAST SHEAR WALLS. the long direction of the panel, unless otherwise marked).
DESIGN BASE SHEAR 948 KIPS 12. Rim joist to top plate 8d (21/2" 0.131") at 6 o.c. j. Casing (11/2 0.080 ) or finish (11/2 0.072 ) nails spaced 6 inches on panel edges, 12 inches at
M-2 "Exterior Glue" In accordance with Tables 2306.4.3 3" 0.131"nail at 6" o.c. intermediate supports.
Particleboard and 2308.9.3(4) 3 14 gage staple at 6 o.c. toenail
5) SNOW LOAD k. Panel supports at 24 inches. Casing or finish nails spaced 6 inches on panel edges, 12 inches at intermediate
supports.
Gypsum sheathing 1/2 inch 16 inches on center 2 - 16d common (31/2 0.162)
GROUND SNOW = 30 PSF (USED TO CALCULATE DRIFT) 13. Top plates, laps and intersections l. For roof sheathing applications, 8d nails (21/2 0.113 ) are the minimum required for wood structural panels.
MIN. ROOF SNOW = 30 PSF 3 - 3 0.131 nails m. Staples shall have a minimum crown width of 7/16 inch.
Gypsum wallboard 1/2 inch 24 inches on center 3 - 3 14 gage staples face nail
IMPORTANCE FACTOR = 1.1 n. For roof sheathing applications, fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports.
SNOW EXPOSURE FACTOR = 1.0 o. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports for subfloor and wall sheathing
Reinforced cement mortar 1 inch 24 inches on center 16d common (31/2" 0.162)
THERMAL FACTOR = 1.0 14. Continuous header, two pieces and 3 inches on center at edges, 6 inches at intermediate supports for roof sheathing.
16o.c. along edge p. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports.
FOUNDATION DESIGN 3 - 8d common (21/2 0.131)
5 - 3 0.131 nails
TABLE 2304.6 MINIMUM THICKNESS OF 15. Ceiling joists to plate
5 - 3 14 gage staples toenail
1) THE FOUNDATION DESIGN IS BASED ON A SOILS WITH 95% COMPACTATION.
WALL SHEATHING
3
2) DRILLED PIER ALLOWABLE DESIGN VALUES: 3/4" = 1'-0"
16. Continuous header to stud 4 - 8d common (21/2 0.131) toenail
A. END BEARING = 17,500 PSF, SIDE SHEAR = 1,750 PSF.
B. EQUIVALENT FLUID PRESSURE (ACTIVE) 40 PCF - GRANULAR BACKFILL. 17. Ceiling joists, laps over partitions 3 - 16d common (31/2 0.162 )
C. EQUIVALENT FLUID PRESSURE (PASSIVE) 240 PCF. (see Section 2308.10.4.1, Table 2308.10.4.1) minimum,Table 2308.10.4.1
D. EQUIVALENT FLUID PRESSURE (AT REST) 80 PCF. 4 - 3 0.131 nails
E. COEFFICIENT OF FRICTION (SILT TO CONCRETE) .4. 4 - 3 14 gage staples face nail
3) FROST DEPTH: 36" BELOW FINISHED GRADE. 18. Ceiling joists to parallel rafters
(see Section 2308.10.4.1, Table 2308.10.4.1) 3 - 16d common (31/2 0.162 )
4) FINAL EXCAVATION ELEVATION MUST BE VERIFIED BY THE GEOTECHNICAL ENGINEER TO minimum,
VERIFY DESIGN BEARING CAPACITY CAN BE MET. Table 2308.10.4.1
4 - 3 0.131 nails
4 - 3 14 gage staples
face nail No. Description Date
MATERIALS OF CONSTRUCTION
19. Rafter to plate
1) NORMAL WEIGHT CONCRETE 28 DAY COMPRESSIVE STRENGTH (see Section 2308.10.1, Table 2308.10.1) 3 - 8d common (21/2 0.131 )
A) FOUNDATION - FOOTINGS, WALLS AND GRADE BEAMS Fc = 4,000 PSI 3 - 3 0.131 nails toenail
B) SLAB ON GRADE Fc = 3,500 PSI 3 - 3 14 gage staples
C) EXPOSED TO VIEW - RETAINING WALLS F'c = 4,000 PSI 20. 1 diagonal brace to each stud and plate
D) DRILLED PIERS (CAISSONS) F'c = 3,000 PSI 2 - 8d common (21/2 0.131 )
E) TOPPING OVER PRECAST F'c = 4,000 PSI 2 - 3 0.131 nails face nail
3 - 3 14 gage staples
2) REINFORCING STEEL ASTM A615
21. 1 8 sheathing to each bearing
- GRADE 60 Fy = 60 KSI 3 - 8d common (21/2 0.131 ) face nail
3) REINFORCING STEEL TO BE WELDED
- ASTM A706 GRADE 60 Fy = 60 KSI 22. Wider than 1 8 sheathing to each bearing 3 - 8d common (21/2 0.131 )
4) WELDED WIRE FABRIC ASTM A185 Fy = 70 KSI face nail
5) STRUCTURAL STEEL
WIDE FLANGE AND TEE SHAPES - ASTM A992 Fy = 50 KSI 23. Built-up corner studs 24 o.c.
ANGLES CHANNELS AND PLATE - ASTM A 36 Fy = 36 KSI 16d common (31/2 0.162 ) 16 o.c.
TUBES - ASTM A500 GRADE B Fy = 46 KSI 3 0.131 nails 16 o.c.
PIPES - ASTM A53 GRADE B Fy = 35 KSI 3 14 gage staples Jaime Corts
BOLTS - ASTM A325 24. Built-up girder and beams
ANCHOR BOLTS - ASTM F1554 GRADE 36 Fy = 36 KSI 20d common (4 0.192 ) 32 o.c. face nail at top and bottom
WELDING ELECTRODES - E70XX 3 0.131 nail at 24 o.c. staggered on opposite sides
METAL ROOF DECKING (GALVANIZED)
ASTM A653 G60 (Z180) ZINC COATING FY = 33 KSI, STRUCT. QUALITY
3 14 gage staple at 24 o.c.
2 - 20d common (4 0.192 ) 2016-12-08-01 Jaime Corts
3 - 3 0.131 nails face nail at ends and at each
6) EXTERIOR WALL FRAMING STUDS - ASTM A570 3 - 3 14 gage staples splice
- 18 TO 25 GAGE Fy = 33 KSI 25. 2 planks 808 South Pierce Street, Burnet, TX, 78611
- 12 TO 16 GAGE Fy = 50 KSI 16d common (31/2 0.162 ) at each bearing
26. Collar tie to rafter
3 - 10d common (3 0.148 ) face nail

2
STRUCTURAL -GENERAL NOTES
CONSTRUCTION NOTES
4 - 3 0.131 nails
4 - 3 14 gage staples Structural Schedule & Details
3/4" = 1'-0"
A. GENERAL CONSTRUCTION NOTES 27. Jack rafter to hip 3 - 10d common (3 0.148 ) toenail
4 - 3 0.131 nails
1. STRUCTURAL DRAWINGS SHOULD NOT BE SCALED. PRINTED DIMENSIONS HAVE PRECEDENCE OVER 4 - 3 14 gage staples
SCALED DRAWINGS AND LARGE SCALE OVER SMALL. 2 - 16d common (31/2 0.162 )
3 - 3 0.131 nails face nail
3 - 3 14 gage staples NOT FOR CONSTRUCTION
2. ALL DRAWINGS AND SPECIFICATIONS ARE CONSIDERED TO BE A PART OF THE CONTRACT
DOCUMENTS. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE CIVIL, 28. Roof rafter to 2-by ridge beam
ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR LOCATION AND SIZE 2 - 16d common (31/2 0.162 )
OF OPENINGS, BLOCKOUTS, FLOOR DEPRESSIONS, CURBS, DIMENSIONS, ETC. NOT INDICATED ON 3 - 3 0.131 nails toenail
THE STRUCTURAL DRAWINGS. THE LOCATION AND SIZE OF MECHANICAL AND ELECTRICAL 3 - 3 14 gage staples Project Number
OPENINGS IN SLABS, WALLS AND DECKS SHALL BE COORDINATED BY THE CONTRACTOR. PROVIDE ALL 2016-12-08-01
2 -16d common (31/2 0.162 )
ADDITIONAL FRAMING OR REINFORCING TO ACCOMMODATE OPENINGS AS REQUIRED BY THE
3 - 3 0.131 nails face nail
Date
APPLICABLE STANDARD DETAILS SHOWN ON THE STRUCTURAL DRAWINGS OR PROVIDED BY THE Issue Date

S0.00
STRUCTURAL ENGINEER. NO HOLES, NOTCHES, BLOCKOUTS, ETC. ARE ALLOWED IN STRUCTURAL 3 - 3 14 gage staples
MEMBERS UNLESS DETAILED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL
Drawn By
ENGINEER. 29. Joist to band joist 3 - 16d common (31/2 0.162 ) Author
4 - 3 0.131 nails face nail Checked By
4 - 3 14 gage staples Checker
DRWNG. NO.
Scale
3/4" = 1'-0"

TABLE 2304.9.1 FASTENING SCHEDULE


4 06/04/2017 1:24:15 p. m.
3/4" = 1'-0"
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
Telephone (786) 502-4836
email customerservice@sdp-us.com

Sim
6
S0.01

24' - 4" 1' - 4" 10' - 1"


2X BRG WALL
(SEE FLOOR PLAN FOR GRADE REINF. SEE
MORE INFORMATION) PLAN
GRADE Sim
REINF. SEE PLAN 7
S0.01

12" MIN 0' - 8"


1' - 8"
IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
12"

CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL


BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
3"
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE

4" 16" 4" (1)#5 REBAR (3)#5 REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
EXPRESSLY DESIGNED.
1' - 4" REBAR
CONT.

1 FOOTING - INTERIOR BRG WALL 6 SINGLE STORY FOOTING


S0.01 1/2" = 1'-0" S0.01 1/2" = 1'-0"

2X BRG WALL
(SEE FLOOR PLAN FOR
OPTIONAL CURB FOR MORE INFORMATION)
MASONRY (1) #5 BAR 0' - 8"
CONT. REINF. SEE
PLAN
GRADE F.F.
VARIES

VARIES
Slab
12" MIN 0' - 8"

Sim
2219.28 Sqft
1' - 0"
1
1' - 8"

34' - 9"
S0.01
REINF. SEE
PLAN
2 STORY: 20" X 20" (2)#5
W/ (3) - #5 CONT. 0' - 4" 1' - 4" 0' - 4" REBAR
(2)#5
1' - 4" REBAR
7 FOOTING - STEP DOWN BRG.
S0.01
2 FOOTING - SECTION AT GARAGE 1/2" = 1'-0"

S0.01 1/2" = 1'-0"

49' - 10"
PROVIDE 13" WIDE FRONT
RECESS AT GARAGE WALL OF
DOOR EXTEND 6" BEYOND GARAGE
F.O.M. EACH END, TYP.
REINF. SEE
4" CONC. DRIVE W/ 1/2" EXP PLAN
JOINTS 10" O.C. TYP.
1' - 8"

REINF. SEE
PLAN

No. Description Date


VARIES

ALIGN DRIVE W/ BOTTOM OF (2)#5


RECESS & PITCH DRIVE 1' - 4" REBAR

2 STORY: 20" X 20"


0' - 8"
0' - 4"
W/ (3) - #5 CONT.
FOOTING - SECTION @ GARAGE 1' - 4"
1' - 4"
3 DOOR 9 FOOTING - STEP DOWN NON BRG.
S0.01 1/2" = 1'-0" S0.01 1/2" = 1'-0"
Sim
2
S0.01 Sim
9

1' - 4"
S0.01

Jaime Corts

2016-12-08-01 Jaime Corts


808 South Pierce Street, Burnet, TX, 78611
1' - 4"

16' - 10" 3' - 11"


Foundation Slab
Sim
3
S0.01

NOT FOR CONSTRUCTION


Concrete slab
5
1/4" = 1'-0"
Project Number
2016-12-08-01
Date
Issue Date
Drawn By

Checked By
Author S0.01
Checker
DRWNG. NO.
Scale
As indicated

06/04/2017 1:24:16 p. m.
GYPSUM BOARD WALL

TRUSSES SPAN
FLASHING IS ATTACHED WITH
JACK STUD SCREWS AND NEOPRENE
DOUBLE TOP PLATE WASHERS

RIDGE MEMBERSA HAVING A


KING STUD TILE ROOF OR OTHER FINISH SLOPE OF LESS 3:12 MUST BE 4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
CRIPPLE OR BLOCKING ROOFING - CLASS A, B, OR C PER DESIGN AS BEAMS Telephone (786) 502-4836
LOCAL CODE REQUIREMENTS email customerservice@sdp-us.com
CORNER BEAD DOUBLE HEADER ROOFING UNDERLAYMENT
ASPHALT SHINGLES
12"
GYPSUM BOARD WALL
KING STUD 5" FELT UNDERLAYMENT
WOOD STRUCTURAL PANEL ROOF
TRUSSES ROOF SHEETING
Ballon Frame - End Wall Detail SHEATHING, SEE STRUCTURAL
3 JACK STUD DRAWINGS 2x6 can span up to 10'-0"
3" = 1'-0" 2x8 can span up to 14'-0" HEADER
2 x 10 can span up to 16'-0" EAVES DRIP
TAPE AND JOINT WOOD TRUSSES AT 24" O.C., 2 x 12 can span up to 22'-0"

VARIES
FASCIA

9' - 0"
COMPOUND SEE STRUCTURAL DRAWINGS
SELF DRILLING
SCREWS.
GUTTER
R38 BATT INSULATION

7' - 0"
BATT INSULATION PER THERMAL W. INSULATION DAM
TO PROVIDE 1" MIN SOFFIT OF PLYWOOD
REQUIREMENTS
CLEAR AIR FLOW CONTINUOUS SCREENED OR
1 LAYER 1/2" GYP. BD. SLOTTED VENT STRIP
5/8" GYPSUM BOARD
FRIEZE BOARD IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
STUD @ 16" C.C. CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
Non Rated Truss Roof Flat Ceiling 11 Balloon Frame - Roof Detail BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
13 ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
1 1/2" = 1'-0" S0.02 1/2" = 1'-0" OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
EXPRESSLY DESIGNED.
SOLE PLATE

GYPSUM
BOARD WALL
Balloon Frame - Door Details
8
1/2" = 1'-0"
TILE ROOF OR OTHER FINISH
ROOFING - CLASS A, B, OR C PER
Ballon Frame- Tee Intersection
7 LOCAL CODE REQUIREMENTS
3" = 1'-0"
ROOFING UNDERLAYMENT
MIN. 19/32" WOOD STRUCTURAL
COMPOUND. PANEL FINISH FLOOR
WOOD STRUCTURAL PANEL ROOF
DOUBLE TOP PLATE MIN. 15/32" WOOD STRUCTURAL

5/8"
PANEL SUBFLOOR, SEE STRUCTURAL SHEATHING, SEE STRUCTURAL
DRAWINGS DRAWINGS
STUD @ 16" C.C.

1/2"
MIN. 1X3 CROSS BRIDGING OR
CRIPPLE OR BLOCKING
0' - 0 1/2"

2X10 SOLID BLOCKING


WOOD TRUSSES AT 24" O.C.,

1' - 0 7/8"
MIN. 2X10 FLOOR JOISTS SEE STRUCTURAL DRAWINGS

11 1/4"
DOUBLE HEADER AT 16" O.C. WITH
FIREBLOCKING PER LOCAL
KING STUD
0' - 3 1/2"

CODES, SEE STRUCTURAL


DRAWINGS
BATT INSULATION PER THERMAL
REQUIREMENTS
JACK STUD

1/2"
MIN. 1/2" TYPE 'X' GYP. BD.
0' - 0 1/2"

2 LAYERS 5/8" TYPE 'X' GYP. BD.


VARIES

9' - 0"

1 HOUR RATED PER UL DESIGN No. FC 5410


WSP= Wood Structural Panel 1 HOUR RATED PER GA FILE No. RC 2602
SELF DRILLING SCREWS
7' - 0"

GYPSUM BOARD WALL 1 Hour Floor 2x Floor Assembly - WSP 1 Hour Truss Roof Flat Ceiling
1 2
1 1/2" = 1'-0" 1 1/2" = 1'-0"
SILL PLATE
Ballon Frame - Butt Joint Detail
5
3" = 1'-0"
CRIPPLE STUD
TAPE AND JOINT
COMPOUND

SELF DRILLING SOLE PLATE


SCREWS. BUILT-UP ROOFING - CLASS A, B, MIN. 2X10 ROOF JOISTS AT
OR C PER LOCAL CODE
REQUIREMENTS
16" O.C., SLOPED PER PLAN,
SEE STRUCTURAL DRAWINGS
No. Description Date
MIN. 15/32" WOOD STRUCTURAL
Balloon Frame - Window Details
9 PANEL ROOF SHEATHING, SEE
1/2" = 1'-0" STRUCTURAL DRAWINGS

STUD @ 16" C.C. MIN. 2X10 ROOF JOISTS AT


16" O.C., SLOPED PER PLAN,
SEE STRUCTURAL DRAWINGS

BATT INSULATION PER


THERMAL REQUIREMENTS
GYPSUM BOARD
WALL
CORNER BEAD. 1' - 4" 1' - 4"
1 LAYER 1/2" TYPE 'X' GYP.
BD. VIEW PERPENDICULAR TO FRAMING VIEW PARALLEL TO
DOUBLE TOP PLATE FRAMING
Ballon Frame - Corner Assembly
6
3" = 1'-0" Jaime Corts
1 HOUR RATED PER IBC 2012 TABLE 721.1 (3), ITEM 13-1.4

1Hour x Roof SlopedFraming 2016-12-08-01 Jaime Corts


GYPSUM WALL 12
STUD @ 16" C.C.
BOARD 1 1/2" = 1'-0"
KING STUD
808 South Pierce Street, Burnet, TX, 78611

JACK STUD
TYPICAL - Wall Details
VARIES

9' - 0"

SOLE PLATE

SELF DRILLING
GYPSUM BOARD 5/8"
SCREW.
NAIL @ 12" O.C. & 6" O.C. NOT FOR CONSTRUCTION
ALONG EDGES

BASE FULL STUD Project Number


2016-12-08-01
FINISH FLOOR
Date
Issue Date
SOLE PLATE

Ballon Frame - Attachment to Floor With


SEALANT
Drawn By

Checked By
Author S0.02
Checker
Base Detail Balloon Frame - Wall Detail DRWNG. NO.
4 10 Scale
3" = 1'-0" 1/2" = 1'-0"
As indicated

06/04/2017 1:24:16 p. m.
Douglas Firlach N2 2X8

4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013


6' - 5" 9' - 0" 9' - 0" 9' - 0" 9' - 0" 8' - 6"
Telephone (786) 502-4836
2' - 0" 4' - 5" 2' - 0" 7' - 0" 2' - 0" 7' - 0" 2' - 0" 7' - 0" 2' - 0" 7' - 0" 2' - 0" 6' - 6" 2' - 0" 2' - 0" 4' - 5" 2' - 0" 7' - 0" 2' - 0" 7' - 0" 2' - 0" 7' - 0" 2' - 0" 7' - 0" 2' - 0" 6' - 6" 2' - 0"
email customerservice@sdp-us.com

1' - 0" 5' - 5" 1' - 0" 8' - 0" 1' - 0" 8' - 0" 1' - 0" 8' - 0" 1' - 0" 8' - 0" 1' - 0" 7' - 6" 1' - 0"
1' - 0" 5' - 5" 1' - 0" 8' - 0" 1' - 0" 8' - 0" 1' - 0" 8' - 0" 1' - 0" 8' - 0" 1' - 0" 7' - 6" 1' - 0"
2' - 0"

1' - 0"

1' - 0"

2' - 0"

2' - 0"

1' - 0"

1' - 0"

2' - 0"
9' - 0"

7' - 0"

8' - 0"

8' - 0"

7' - 0"

9' - 0"
2' - 0" 2' - 0"
2' - 0"
2' - 0"

1' - 0"

1' - 0"

2' - 0"
IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
9' - 0"

7' - 0"

8' - 0"

8' - 0"

7' - 0"

9' - 0"
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
EXPRESSLY DESIGNED.

31' - 10 1/2"
(2) Douglas
2' - 0"

1' - 0"

1' - 0"

2' - 0"

36' - 7"
Firlach Sel
Douglas Firlach Structural 2x8
9' - 0"

7' - 0"

8' - 0"

8' - 0"

7' - 0"

9' - 0"
N2 2X8 @24"
2' - 0"

1' - 0"

1' - 0"

2' - 0"

1' - 4"
Sim
4

8' - 0"

7' - 0"

9' - 0"
S1.01 1' - 4"

1' - 4"
1' - 0"

2' - 0"

10' - 0 3/4"
1' - 4"

5' - 4 1/4"
1' - 0" 8' - 0" 1' - 0" 8' - 0" 1' - 0" 7' - 6" 1' - 0" Entry slab
41.72 sqft
1' - 4" Garage SLAB
2' - 0" 7' - 0" 2' - 0" 7' - 0" 2' - 0" 6' - 6" 2' - 0" 397.88 sqft

9' - 0" 9' - 0" 8' - 6"

9' - 7 3/4"

9' - 7 3/4"
12' - 2 3/4" 7' - 9 1/2" 11' - 8 3/4"

First Floor 1 No. Description Date


2
Footing Plan - Structural 3/16" = 1'-0"
1
3/16" = 1'-0"

TABLE 2308.8(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 psf Dead Load =10psf, L/ = 360)
Table FJ-3
Design Criteria: Strength - 40 lbs. per sq. ft. live load, plus 10 lbs. per sq. ft. dead load.
Deflection - Limited in span in inches divided by 360 for live load only.
Span (feet and inches) Jaime Corts
Species 2x6 2x8 2 x 10 2 x 12 joist wood 8"
or Group Grade 12" 16" 19.2" 24" 12" 16" 19.2" 24" 12" 16" 19.2" 24" 12" 16" 19.2" 24" (2) Douglas FirLarch 2x8

Douglas FirLarch
Sel. Struc. 11-4 10-4 9-8 9-0 15-0 13-7 12-10 11-11 19-1 17-4 16-4 15-2 23-3 21-1 19-10 18-5
2016-12-08-01 Jaime Corts

8"
No.1 & Btr. 11-2 10-2 9-6 8-10 14-8 13-4 12-7 11-8 18-9 17-0 16-0 14-9 22-10 20-9 19-1 17-1
14-5 13-1 12-4 11-0 18-5 16-5 15-0 13-5 22-0 19-1 17-5 15-7
2' - 0"

JOIST SPAN No.1 10-11 9-11 9-4 8-8


2" 2"
14-2 12-9 11-8 10-5 18-0 15-7 14-3 12-9 20-11 18-1 16-6 14-9

8"
No.2 10-9 9-9 9-2 8-3 4#4
No.3 8-11 7-8 7-0 6-3 11-3 9-9 8-11 8-0 13-9 11-11 10-11 9-9 16-0 13-10 12-7 11-3 #3@8"
808 South Pierce Street, Burnet, TX, 78611
earth

8"
Douglas Fir-South
Sel. Struc. 10-3 9-4 8-9 8-2 13-6 12-3 11-7 10-9 17-3 15-8 14-9 13-8 21-0 19-1 17-11 16-8
No.1 10-0 9-1 8-7 7-11 13-2 12-0 11-3 10-6 16-10 15-3 14-5 12-11 20-6 18-4 16-9 15-0 concrete

FOUNDATION Pier beams


12"
No.2 9-9 8-10 8-4 7-9 12-10 11-8 11-0 10-2 16-5 14-11 13-10 12-5 19-11 17-7 16-1 14-4
No.3 8-8 7-6 6-10 6-2 11-0 9-6 8-8 7-9 13-5 11-8 10-7 9-6 15-7 13-6 12-4 11-0
Hem-Fir
12"
8"

max joint span Sel. Struc. 10-9 9-9 9-2 8-6 14-2 12-10 12-1 11-3 18-0 16-5 15-5 14-4 21-11 19-11 18-9 17-5
15-4" No.1 & Btr. 10-6 9-6 9-0 8-4 13-10 12-7 1 1-10 11-0 17-8 16-0 15-1 14-0 21-6 19-6 18-3 16-4
3" 18" 3"
Species group: No.1 10-6 9-6 9-0 8-4 13-10 12-7 11-10 10-10 17-8 16-0 14-10 13-3 21-6 18-10 17-2 15-5
Douglass Fir-Larch No.2 10-0 9-1 8-7 7-11 13-2 12-0 11-3 10-2 16-10 15-2 13-10 12-5 20-4 17-7 16-1 14-4
No.3 8-8 7-6 6-10 6-2 11-0 9-6 8-8 7-9 13-5 11-8 10-7 9-6 15-7 13-6 12-4 11-0
24" NOT FOR CONSTRUCTION
Spacing:
16" O.C. Spruce- Pine-Fir (South)
Sel. Struc. 10-0 9-1 8-7 7-11 13-2 12-0 11-3 10-6 16-10 15-3 14-5 13-4 20-6 18-7 17-6 16-3 Typical Interior Footing Detail
2 X 10 Grade No.2 No.1 9-9 8-10 8-4 7-9 12-10 11-8 11-0 10-2 16-5 14-11 14-0 12-7 19-11 17-10 16-3 14-7 4
22'-0" @16" o.c. 1/2" = 1'-0" Project Number
No.2 9-6 8-7 8-1 7-6 12-6 11-4 10-8 9-8 15-11 14-6 13-3 11-10 19-4 16-10 15-4 13-9
2016-12-08-01
No.3 8-3 7-2 6-6 5-10 10-5 9-0 8-3 7-5 12-9 11-0 10-1 9-0 14-9 12-10 11-8 10-5
DISCLAIMER NOTE:
Western Woods
Date
ALL STRUCTURAL MUST BE REVISED BY Issue Date

S1.01
LICENSE ENGINEER IN THE STATE Sel. Struc. 9-9 8-10 8-4 7-9 12-10 11-8 11-0 1 0-2 16-5 14-11 14-0 12-9 19-11 18-1 16-6 14-9
WHICH THE PROJECT WILL BE No.1 9-6 8-7 8-0 7-2 12-6 11-1 10-1 9-0 15-7 13-6 12-4 11-0 18-1 15-8 14-4 12-10 Drawn By
CONTRUCTED. No.2 9-2 8-4 7-10 7-2 12-1 11-0 10-1 9-0 15-5 13-6 12-4 11-0 18-1 15-8 14-4 12-10 Author
No.3 13-6 11-8 10-8 9-6
7-6 6-6 5-11 5-4 9-6 8-3 7-6 6-9 11-8 10-1 9-2 8-3 Checked By
Checker
DRWNG. NO.
FLOOR JOISTS - Span Tablesfor Species Scale
3 As indicated
3/4" = 1'-0"

06/04/2017 1:24:18 p. m.
TABLE 2308.9.5 HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS
(Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)

Non - Bearing - Wall Schedule GROUND SNOW LOAD (psf)e


30 50
Dimensions HEADERS SUPPORTING
SI Building widthc (feet)
Keynote Type Mark Type Function Structural Usage Width Length Area
ZE Span
20
NJd Span
28
NJd Span
36
NJd Span
20
NJd Span
28
NJd Span
36
NJd
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 51' - 11" 595 SF Roof & Ceiling 2-24 3-6 1 3-2 1 2-10 1 3-2 1 2-9 1 2-6 1
5-5 1 4-8 1 4-2 1 4-8 1 4-1 1 3-8 2
4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
2-26
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 26' - 5" 221 SF
2-28 6-10 1 5-11 2 5-4 2 5-11 2 5-2 2 4-7 2 Telephone (786) 502-4836
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 5' - 0 1/4" 29 SF 2-210 8-5 2 7-3 2 6-6 2 7-3 2 6-3 2 5-7 2 email customerservice@sdp-us.com
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 12' - 10 3/4" 143 SF 2-212 9-9 2 8-5 2 7-6 2 8-5 2 7-3 2 6-6 2
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 5' - 0 1/4" 51 SF 3-28 8-4 1 7-5 1 6-8 1 7-5 1 6-5 2 5-9 2
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 12' - 2" 116 SF 3-210 10-6 1 9-1 2 8-2 2 9-1 2 7-10 2 7-0 2
3-212 12-2 2 10-7 2 9-5 2 10-7 2 9-2 2 8-2 2
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 36' - 10" 351 SF HEADER SPAN
4-28 9-2 1 8-4 1 7-8 1 8-4 1 7-5 1 6-8 1
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 12' - 2" 112 SF 11-8 1 10-6 1 9-5 2 10-6 1 9-1 2 8-2 2
4-210
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 7' - 6" 92 SF 4-212 14-1 1 12-2 2 10-11 2 12-2 2 10-7 2 9-5 2
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 7' - 2 1/4" 61 SF
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 7' - 6" 91 SF Roof, Ceiling & 1 2-24 3-1 1 2-9 1 2-5 1 2-9 1 2-5 1 2-2 1
Center-Bearing Floor 2-26 4-6 1 4-0 1 3-7 2 4-1 1 3-7 2 3-3 2
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 12' - 11" 120 SF
2-28 5-9 2 5-0 2 4-6 2 5-2 2 4-6 2 4-1 2
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 15' - 1" 175 SF 2-210 7-0 2 6-2 2 5-6 2 6-4 2 5-6 2 5-0 2
Exterior - Wood Shingle on Wood Stud Exterior Non-bearing 0' - 7 1/4" 18' - 11" 114 SF 2-212 8-1 2 7-1 2 6-5 2 7-4 2 6-5 2 5-9 3
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 10' - 7 3/4" 101 SF 3-28 7-2 1 6-3 2 5-8 2 6-5 2 5-8 2 5-1 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 14' - 7 1/2" 184 SF 3-210 8-9 2 7-8 2 6-11 2 7-11 2 6-11 2 6-3 2
3-212 10-2 2 8-11 2 8-0 2 9-2 2 8-0 2 7-3 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 18' - 8" 289 SF
4-28 8-1 1 7-3 1 6-7 1 7-5 1 6-6 1 5-11 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 11' - 6 1/4" 143 SF 4-210 10-1 1 8-10 2 8-0 2 9-1 2 8-0 2 7-2 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 3' - 6" 35 SF 4-212 11-9 2 10-3 2 9-3 2 10-7 2 9-3 2 8-4 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 11' - 2" 135 SF IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE
Roof, Ceiling & 1 2-24 2-8 1 2-4 1 2-1 1 2-7 1 2-3 1 2-0 1 CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 3' - 3" 36 SF
Clear Span Floor 2-26 3-11 1 3-5 2 3-0 2 3-10 2 3-4 2 3-0 2 BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 9' - 1 1/4" 101 SF 2-28 5-0 2 4-4 2 3-10 2 4-10 2 4-2 2 3-9 2
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 9' - 1 1/4" 121 SF 2-210 6-1 2 5-3 2 4-8 2 5-11 2 5-1 2 4-7 3 REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
EXPRESSLY DESIGNED.
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 22' - 7 1/4" 256 SF 2-212 7-1 2 6-1 3 5-5 3 6-10 2 5-11 3 5-4 3
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 3' - 1 3/4" 37 SF 3-28 6-3 2 5-5 2 4-10 2 6-1 2 5-3 2 4-8 2
3-210 7-7 2 6-7 2 5-11 2 7-5 2 6-5 2 5-9 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 13' - 10 3/4" 199 SF
3-212 8-10 2 7-8 2 6-10 2 8-7 2 7-5 2 6-8 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 6' - 11 3/4" 100 SF 4-28 7-2 1 6-3 2 5-7 2 7-0 1 6-1 2 5-5 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 12' - 0 1/2" 137 SF 4-210 8-9 2 7-7 2 6-10 2 8-7 2 7-5 2 6-7 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 14' - 11 1/4" 187 SF 4-212 10-2 2 8-10 2 7-11 2 9-11 2 8-7 2 7-8 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 8' - 3 3/4" 84 SF 2-24 2-7 1 2-3 1 2-0 1 2-6 1 2-2 1 1-11 1
Roof, Ceiling & 2 Center-
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 2' - 9 1/2" 38 SF 2-26 3-9 2 3-3 2 2-11 2 3-8 2 3-2 2 2-10 2
Bearing Floors
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 2' - 10" 35 SF 2-28 4-9 2 4-2 2 3-9 2 4-7 2 4-0 2 3-8 2
2-210 5-9 2 5-1 2 4-7 3 5-8 2 4-11 2 4-5 3
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 8' - 3 3/4" 83 SF
2-212 6-8 2 5-10 3 5-3 3 6-6 2 5-9 3 5-2 3
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 12' - 0 1/2" 130 SF 3-28 5-11 2 5-2 2 4-8 2 5-9 2 5-1 2 4-7 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 6' - 1 1/2" 77 SF 3-210 7-3 2 6-4 2 5-8 2 7-1 2 6-2 2 5-7 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 2' - 10 1/2" 33 SF 3-212 8-5 2 7-4 2 6-7 2 8-2 2 7-2 2 6-5 3
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 6' - 5 1/4" 96 SF 4-28 6-10 1 6-0 2 5-5 2 6-8 1 5-10 2 5-3 2
4-210 8-4 2 7-4 2 6-7 2 8-2 2 7-2 2 6-5 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 4' - 6 1/4" 40 SF
4-212 9-8 2 8-6 2 7-8 2 9-5 2 8-3 2 7-5 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 2' - 11 1/4" 26 SF
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 2' - 11 1/4" 26 SF
2-24 2-1 1 1-8 1 1-6 2 2-0 1 1-8 1 1-5 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 2' - 3" 7 SF Roof, Ceiling & 2 Clear Span
2-26 3-1 2 2-8 2 2-4 2 3-0 2 2-7 2 2-3 2
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 2' - 3" 7 SF Floors
2-28 3-10 2 3-4 2 3-0 3 3-10 2 3-4 2 2-11 3
Interior - 4 1/2" Partition Interior Non-bearing 0' - 4 1/2" 4' - 3 3/4" 11 SF 2-210 4-9 2 4-1 3 3-8 3 4-8 2 4-0 3 3-7 3
09 22 00 W-20 (W-20) Exterior - Wood Siding on Wood Stud Exterior Non-bearing 0' - 7 1/4" 5' - 5 1/4" 17 SF 2-212 5-6 3 4-9 3 4-3 3 5-5 3 4-8 3 4-2 3
09 22 00 W-20 (W-20) Exterior - Wood Siding on Wood Stud Exterior Non-bearing 0' - 7 1/4" 7' - 9 1/2" 27 SF 3-28 4-10 2 4-2 2 3-9 2 4-9 2 4-1 2 3-8 2
3-210 5-11 2 5-1 2 4-7 3 5-10 2 5-0 2 4-6 3
09 22 00 W-20 (W-20) Exterior - Wood Siding on Wood Stud Exterior Non-bearing 0' - 7 1/4" 5' - 5 1/4" 17 SF
3-212 6-10 2 5-11 3 5-4 3 6-9 2 5-10 3 5-3 3
4-28 5-7 2 4-10 2 4-4 2 5-6 2 4-9 2 4-3 2
4-210 6-10 2 5-11 2 5-3 2 6-9 2 5-10 2 5-2 2
4-212 7-11 2 6-10 2 6-2 3 7-9 2 6-9 2 6-0 3

TABLE 2308.9.5 HEADER AND GIRDER


SPANSa FOR EXTERIOR BEARING WALLS
(Maximum Spans for Douglas Fir-Larch,
Hem-Fir, Southern Pine and
Spruce-Pine-Firb and Required Number of
Jack Studs)
1
1/2" = 1'-0"

TABLE 2308.9.6 HEADER AND GIRDER SPANSa FOR INTERIOR BEARING WALLS
(Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)

HEADER SPAN
SIZE 20 28
Building widthc (feet)
36 20 28 36
No. Description Date
Span NJd Span NJd Span NJd Span NJd Span NJd Span NJd
2-24 2-7 1 2-3 1 2-0 1 2-6 1 2-2 1 1-11 1
One Floor Only
2-26 3-9 2 3-3 2 2-11 2 3-8 2 3-2 2 2-10 2
2-28 4-9 2 4-2 2 3-9 2 4-7 2 4-0 2 3-8 2
2-210 5-9 2 5-1 2 4-7 3 5-8 2 4-11 2 4-5 3
2-212 6-8 2 5-10 3 5-3 3 6-6 2 5-9 3 5-2 3
3-28 5-11 2 5-2 2 4-8 2 5-9 2 5-1 2 4-7 2
3-210 7-3 2 6-4 2 5-8 2 7-1 2 6-2 2 5-7 2
3-212 8-5 2 7-4 2 6-7 2 8-2 2 7-2 2 6-5 3
4-28 6-10 1 6-0 2 5-5 2 6-8 1 5-10 2 5-3 2
4-210 8-4 2 7-4 2 6-7 2 8-2 2 7-2 2 6-5 2
4-212 9-8 2 8-6 2 7-8 2 9-5 2 8-3 2 7-5 2
2-24 2-1 1 1-8 1 1-6 2 2-0 1 1-8 1 1-5 2
Two Floors
2-26 3-1 2 2-8 2 2-4 2 3-0 2 2-7 2 2-3 2
2-28 3-10 2 3-4 2 3-0 3 3-10 2 3-4 2 2-11 3
2-210 4-9 2 4-1 3 3-8 3 4-8 2 4-0 3 3-7 3
2-212 5-6 3 4-9 3 4-3 3 5-5 3 4-8 3 4-2 3
3-28 4-10 2 4-2 2 3-9 2 4-9 2 4-1 2 3-8 2
3-210 5-11 2 5-1 2 4-7 3 5-10 2 5-0 2 4-6 3
Jaime Corts
3-212 6-10 2 5-11 3 5-4 3 6-9 2 5-10 3 5-3 3
4-28 5-7 2 4-10 2 4-4 2 5-6 2 4-9 2 4-3 2
4-210 6-10 2 5-11 2 5-3 2 6-9 2 5-10 2 5-2 2
4-212 7-11 2 6-10 2 6-2 3 7-9 2 6-9 2 6-0 3 2016-12-08-01 Jaime Corts

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.


808 South Pierce Street, Burnet, TX, 78611

a. Spans are given in feet and inches (ft-in).

b. Tabulated values are for No. 2 grade lumber. Ballon frame Notes
c. Building width is measured perpendicular to the ridge. For widths between those shown, spans are permitted to be interpolated.

d. NJ - Number of jack studs required to support each end. Where the number of required jack studs equals one, the headers are permitted to be
supported by an approved framing anchor attached to the full-height wall stud and to the header.

NOT FOR CONSTRUCTION


DISCLAIMER NOTE:
Wall Layout provided by Others.
Wall Framing Plan is for manufacturer reference only.
Project Number
2016-12-08-01
Date
TABLE 2308.9.6 HEADER AND GIRDER Issue Date

2
SPANSa FOR INTERIOR BEARING WALLS
1/2" = 1'-0"
Drawn By

Checked By
Author S2.01
Checker
DRWNG. NO.
Scale
1/2" = 1'-0"

06/04/2017 1:24:19 p. m.
DISCLAIMER NOTE:
Truss Layout provided by Others.
Roof Framing Plan is for manufacturer reference only. 4380 EAST 11th AVENUE, HIALEAH, FLORIDA 33013
Mono truss Douglas Telephone (786) 502-4836
DISCLAIMER MOTE Firlach Select email customerservice@sdp-us.com
2 Structural Mono truss
3/4" = 1'-0" Douglas Firlach
Douglas FirLarch N1 2 x 10 @16" Select Structural

2' - 0"
1' - 4"

IF THESE DRAWINGS OR ANY PART THEREOF IS REPRODUCED WITHOUT THE

24
CONSENT OF THE ARCHITECT OR THE ENGINEER THE PERSON SO DOING WILL

'-
BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION.

31
ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT
OR THE ENGINEER ARE THE PROPERTY OF THE ARCHITECTS AND SHALL NOT BE

/4"
2' - 0" REUSED ON ANY OTHER LOCATION EXCEPT THE ONE FOR WHICH THEY WERE
2 x 12" EXPRESSLY DESIGNED.

(3) Douglas Firlach select struct 2x12

Varies

1' - 4"

41' - 5"
14' - 5" Douglas FirLarch N2 2 x 8 @16"

Varies Douglas FirLarch N2 Douglas FirLarch


2 x 6 @16" N1 2 x 10 @
16"

1' - 4"
56' - 6"

24
'-
7
5/
Mono Truss
5

8"
1/4" = 1'-0"
Mono truss Douglas
Firlach Select
1' - 4"
Structural

2' - 0"

2' - 0"
2' - 0"
Mono truss
19' - 8"
CONVERSION FACTORS FOR RAFTERS
Douglas Firlach Douglas
2' - 0" select structural FirLarch N
SLOPE IN FACTOR DESCRIPTION: DISCLAIMER NOTE: 2x10 3 2x6 @
No. Description Date

9' - 7 3/4"
12" SLOPE SLOPE: 3"/12" ALL STRUCTURAL MUST BE REVISED BY LICENSE 24"
Horizontal rafter Span: 7'-9" ENGINEER IN THE STATE WHICH THE PROJECT WILL
TH 1" 1.003 (2) Douglas Firlach select
NG Species group: Douglass Fir-Larch BE CONTRUCTED.
LE 2" 1.014 struct 2x12
ER
A FT 3" 1.031
CALCULATION:
LR CE 4" 1.054
RAL AN
Douglas
5" 1.083

2' - 0"
E T
OV DIS 6" 1.118 7'-9" X 1.031 =7'-11 7/8" FirLarch No 2
G 2x6 @ 16"
O PIN 7" 1.158
SL 8" 1.202 TABLE FJ-3
9" 1.250
2 X 8 Grade No.2 23' - 7" 12' - 2 3/4"
10" 1.302
HORIZONTAL RAFTER SPAN 11" 1.357 8'-0" @16" o.c.
12" 1.414

40# LIVE LOAD 10# DEAD LOAD L/360


Table FJ-3 (3) Douglas Firlach
select structural
Design Criteria: Strength - 40 lbs. per sq. ft. live load, plus 10 lbs. per sq. ft. dead load.
2x12
Deflection - Limited in span in inches divided by 360 for live load only.
Span (feet and inches)
Species 2x6 2x8 2 x 10 2 x 12
Jaime Corts
or Group Grade 12" 16" 19.2" 24" 12" 16" 19.2" 24" 12" 16" 19.2" 24" 12" 16" 19.2" 24"
Douglas FirLarch Roof Plan
1
Sel. Struc. 11-4 10-4 9-8 9-0 15-0 13-7 12-10 11-11 19-1 17-4 16-4 15-2 23-3 21-1 19-10 18-5 3/16" = 1'-0"
No.1 & Btr.
No.1
11-2
10-11
10-2
9-11
9-6
9-4
8-10
8-8
14-8
14-5
13-4
13-1
12-7
12-4
11-8
11-0
18-9
18-5
17-0
16-5
16-0
15-0
14-9
13-5
22-10
22-0
20-9
19-1
19-1
17-5
17-1
15-7 2016-12-08-01 Jaime Corts
No.2 10-9 9-9 9-2 8-3 14-2 12-9 11-8 10-5 18-0 15-7 14-3 12-9 20-11 18-1 16-6 14-9
No.3 8-11 7-8 7-0 6-3 11-3 9-9 8-11 8-0 13-9 11-11 10-11 9-9 16-0 13-10 12-7 11-3
Douglas Fir-South 808 South Pierce Street, Burnet, TX, 78611
Sel. Struc. 10-3 9-4 8-9 8-2 13-6 12-3 11-7 10-9 17-3 15-8 14-9 13-8 21-0 19-1 17-11 16-8
No.1 10-0 9-1 8-7 7-11 13-2 12-0 11-3 10-6 16-10 15-3 14-5 12-11 20-6 18-4 16-9 15-0 TABLE 2308.9.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
No.2 9-9 8-10 8-4 7-9 12-10 11-8 11-0 10-2 16-5 14-11 13-10 12-5 19-11 17-7 16-1 14-4
No.3 8-8 7-6 6-10 6-2 11-0 9-6 8-8 7-9 13-5 11-8 10-7 9-6 15-7 13-6 12-4 11-0 BEARING WALLS NONBEARING WALLS ROOF - Plans & Details
Hem-Fir
Sel. Struc. 10-9 9-9 9-2 8-6 14-2 12-10 12-1 11-3 18-0 16-5 15-5 14-4 21-11 19-11 18-9 17-5 Laterally Supporting Supporting one Supporting two Laterally
No.1 & Btr. 10-6 9-6 9-0 8-4 13-10 12-7 1 1-10 11-0 17-8 16-0 15-1 14-0 21-6 19-6 18-3 16-4 unsupported roof and floor, roof and floors, roof and unsupported
STUD stud heighta ceiling only ceiling ceiling stud heighta Spacing
No.1 10-6 9-6 9-0 8-4 13-10 12-7 11-10 10-10 17-8 16-0 14-10 13-3 21-6 18-10 17-2 15-5
SIZE (feet) (feet) (inches)
No.2 10-0 9-1 8-7 7-11 13-2 12-0 11-3 10-2 16-10 15-2 13-10 12-5 20-4 17-7 16-1 14-4
(inches)
No.3 8-8 7-6 6-10 6-2 11-0 9-6 8-8 7-9 13-5 11-8 10-7 9-6 15-7 13-6 12-4 11-0
NOT FOR CONSTRUCTION
Spruce- Pine-Fir (South) Spacing (inches)
Sel. Struc. 10-0 9-1 8-7 7-11 13-2 12-0 11-3 10-6 16-10 15-3 14-5 13-4 20-6 18-7 17-6 16-3
No.1 9-9 8-10 8-4 7-9 12-10 11-8 11-0 10-2 16-5 14-11 14-0 12-7 19-11 17-10 16-3 14-7 2 3b - - - - 10 16
No.2 9-6 8-7 8-1 7-6 12-6 11-4 10-8 9-8 15-11 14-6 13-3 11-10 19-4 16-10 15-4 13-9
24 10 24 16 - 14 24 Project Number
No.3 8-3 7-2 6-6 5-10 10-5 9-0 8-3 7-5 12-9 11-0 10-1 9-0 14-9 12-10 11-8 10-5
2016-12-08-01
Western Woods
Sel. Struc. 19-11 18-1 16-6 14-9
34 10 24 24 16 14 24 Date
9-9 8-10 8-4 7-9 12-10 11-8 11-0 1 0-2 16-5 14-11 14-0 12-9
Issue Date

S3.01
No.1 9-6 8-7 8-0 7-2 12-6 11-1 10-1 9-0 15-7 13-6 12-4 11-0 18-1 15-8 14-4 12-10
25 10 24 24 - 16 24
No.2 9-2 8-4 7-10 7-2 12-1 11-0 10-1 9-0 15-5 13-6 12-4 11-0 18-1 15-8 14-4 12-10 Drawn By
No.3 7-6 6-6 5-11 5-4 9-6 8-3 7-6 6-9 11-8 10-1 9-2 8-3 13-6 11-8 10-8 9-6 Author
26 10 24 24 16 20 24
Checked By
Checker
RAFTER JOISTS - Span Tablesfor Species TABLE 2308.9.1 SIZE, HEIGHT AND DRWNG. NO.
Scale
Copy 1 SPACING OF WOOD STUDS
3 4 As indicated
3/4" = 1'-0" 3/4" = 1'-0"
06/04/2017 1:24:19 p. m.

Das könnte Ihnen auch gefallen