Circuit Voltage
SMCS - 1400; 1450
Circuit Faults
The following information will describe the circuit malfunctions of series,
parallel, and series parallel circuits.
Circuit Malfunctions
There are several ways that a circuit can malfunction. Most electrical
malfunctions are caused by the following conditions: opens, shorts, grounds, high
resistance, or intermittents.
Opens
An open in any part of a circuit is an extremely high resistance that results in no
current flow in the circuit. An open can be caused by any of the following
components that have failed:
Switch
Fuse
Broken wire
Connector
Component (load)
The physical location of the open determines how the circuit will react. In a
series circuit, any open connection will result in no current flow in the circuit.
Illustration 1 shows an open in a series circuit. The switch acts as an open.
Therefore, no current will flow through the two loads when the switch is open.
Illustration 1 g01070634
If the open occurs in any of the branches below the main line, only the load on
that specific branch is affected. All other branch loads will operate normally.
Illustration 2 shows an example of an open in the main line and in a parallel
branch.
Illustration 2 g01070636
Shorts
A short in a circuit is a direct electrical connection between two points. There is
usually a very low resistance or opposition to current flow. A short in a circuit
often describes an unwanted or an incorrect electrical connection. This may draw
higher than expected current. In describing malfunctions that are caused by
electrical shorts, the types of shorts are usually identified as a short to ground or a
short to power.
A short to ground occurs when current flow is grounded before it was intended to
be. This usually happens when wire insulation breaks and the conductor actually
comes in contact with the machine ground. The effect of a short to ground
depends on the design of the circuit and on the location in relationship to other
circuit components (protection devices, switches, loads).
Illustration 3 g01070638
Illustration 3 shows the short occurring after the protection device and the switch,
but before the circuit load (lamp). In this example, a low resistance path to
ground occurs whenever the switch is turned on and the source voltage is
available. The result of this unwanted path will result in a blown fuse when the
switch is turned on.
Illustration 4 shows the short to ground occurring before the switch. This
condition is often referred to as a dead short. In this situation, the fuse will blow
anytime that the circuit voltage is applied.
Illustration 4 g01070640
A short to power occurs when one circuit is shorted to another circuit. The
symptoms of a short to power depends on the location of the short. The result of
this of condition generally causes one or both circuits to operate improperly. A
component that is being energized when it is not supposed to be is an example.
The root cause of this condition is caused by worn electrical wiring or frayed
electrical wiring. Also, this condition seldom causes protection devices to open or
cause damage to other components.
Illustration 5 shows the short to power occurring before the controlling devices
(switches). This condition allows both switches to control the two loads.
Illustration 5 g01070643
Illustration 6 shows the short to power that occurrs after the load in one branch,
and before the load in the other. In this case, if the switch that controlls circuit no.
2 is turned on, the load does illuminate, but if the switch that controls circuit no.
1 is turned on, a direct short to ground occurs resulting in the fuse blowing.
Illustration 6 g01070646
Grounds
A grounded circuit usually results in a component that fails to operate. A
grounded condition indicates that the circuit has an unwanted path to the machine
frame. The effect on the circuit is determined by where the ground occurs.
High Resistance
Circuit malfunctions also occur when resistance levels become too high. The
circuit effect usually results in the component failing to operate or the component
does not operate according to specification. The cause of high resistance is a
build up of corrosion on connections, or dirt on connections and on contacts.
Intermittent
An intermittent condition occurs when contacts or connections become loose or
when internal component parts break. These problems usually results in lights
flickering, or in components working intermittently. This problem usually
appears as the result of vibrations or machines moving. These problems are not
easily diagnosed because the condition corrects itself when the machine is
stopped.