Analysis and Design of Four Story Reinforced Concrete Building using STAAD Pro and the NSCP 2010

Appendix B

3 1.208 2 1.4
LOAD 16 COMBINATION LOAD CASE 16 1.208DL - 1.4EQz
REPEAT LOAD
3 1.208 2 -1.4
*** END OF LOAD COMBINATION TREATED AS PRIMARY LOADS ***
*** ANALYSIS OF STRUCTURE USING SECOND ORDER ANALYSIS
PDELTA ANALYSIS CONVERGE
LOAD LIST 6 TO 16
PRINT STORY DRIFT
PRINT SUPPORT REACTION
PRINT MEMBER FORCES LIST 350
*** DESIGN OF CONCRETE MEMBERS SHALL USE ACI 1999
START CONCRETE DESIGN
CODE ACI
EFACE 0.25 MEMB 1 TO 332
MAXMAIN 50 MEMB 1 TO 332
MINMAIN 16 MEMB 1 TO 332
MINSEC 10 MEMB 1 TO 332
RHOMN 0.01 MEMB 333 TO 412
SFACE 0.25 MEMB 1 TO 332
TRACK 1 ALL
DESIGN BEAM 1 TO 332
DESIGN COLUMN 333 TO 412
END CONCRETE DESIGN
FINISH