Sie sind auf Seite 1von 1

Advanced Test Equipment Rentals

E stablished 1981 www.atecorp.com 800-404-ATEC (2832)

Spectrum Analyzers 16

Affordable, High-Stability 3 .6-GHz Spectrum Analyzer

~r .

a wa ~`isvlP.'

9
U ,iii
a iJ
D
TR4171

016
o~
1
N
Ow Spectrum Analyzer
u ow D L 10 Hz to 120 MHz with resolution to 3
Hz
C High input sensitivity: -150 dBm
Amplitude characteristics, phase and
11i1itltitit~ group delay characteristic
measurements
Quasipeak-value measurements,
occupied bandwidth measurement,
TR4135 Spectrum Analyzer adjacent-channel leakage power
measurements, Smith chart display
impedance measurements and gated
Wide band coverage : 10 kHz to 3 .6 GHz (Specifications) sweep (optional)
Wide input level range : -131 to +20 Frequency
dBm Frequency range: 10 kHz to 3 .6 GHz The TR4171 is a spectrum analyzer capable
High-precision frequency measurement Noise sidebands : of phase and group delay measurements
to 30-Hz resolution e6 deatta 100 dss1tr tog deft over the range 10 Hz to 120 MHz . It uses a
High-Q device frequency measurements 14 oaat 104 tr dMt 20"~ built-in processor to perform spectrum
in combination with the TR4154 analysis with an input sensitivity of -150
Stability:
Tracking Generator dBm and a maximum resolution of 3 Hz . Its
Frequency drift 500 Hzhnln, span 9 2
3-Decade log sweep MHz high-purity local oscillator enables high
Direct reading of field strength and Residual FM 30 Hzp-p max, span S 2 C/N measurements and a gated sweep
quasipeak-value measurements MHz function ensures high-accuracy spectrum
conforming CISPR standards Resolution: analysis of burst signals .
GPIB provided as standard for full 3-dB bandwidth 30 Hz to 1 MHz
remote operation 6-dB bandwidth 200 Hz, 9 kHz. 120 kHz (Specifications)
Amplitude
Measurement range : 10 Hz to 120 MHz
Measurement range: -131 dBm to +20 dBm
The TR4135 Spectrum Analyzer uses a Noise sidebands: -125 dBc/Hz (min value at
Dynamic range:
synthesized local oscillator to enable high- 20 kHz from the carrier)
Average noise level
stability spectrum analysis . It features Stability (frequency span ~_ 5 .0 kHz):
-116 dBm +1 .55 f (GHz) dB max . (at
frequency coverage from 10 kHz to 3.6 GHz, Drift 1 Hz/min max ., 10 Hz/30 minutes
1-kHz resolution bandwidth)
max .
input range of -131 to +20 dBm, a 2nd and 3rd order distortion -70 dB
Residual FM 0 .2 Hzp-p/s max.
maximum resolution of 30 Hz, residual FM max . (-30-dBm input level, at 10 MHz
Resolution :
of 30 Hzp-p and skirt noise characteristics or greater)
3-dB bandwidth 3 Hz to 100 kHz in 1-3
of -105 dBc/Hz at 20 kHz from the carrier . Residual response -100 dbm max . (at
sequence steps
The TR4135 is suitable for measurements 100 kHz or greeter) Amplitude
Sweep
on 900-MHz mobile radiotelephone Measuresseut range: -150 dBm to +30 dBm
Sweep time : 50 ma to 1000 s
equipment, fixed broadcast stations and Trigger modes: Free-run, line, video, Average noise level: -140 dBm max. (3-Hz
mobile A-band equipment. It can be used bandwidth resolution, 1-Hz video
external, single, TV-V bandwidth, 0-dBm input attenuation)
for satellite broadcast received field- Input
-155 dBm in 50 A and 75 (1 high-
strength measurements and in the Maximum input level : +20 dBm (at 20-dB
sensitivity mode with 3-Hz bandwidth
evaluation and testing of CATV equipment . input attenuation or greater)
resolution . 1-Hz video bandwidth and
It enables high-precision frequency 25 VDC max .
0-dBm input attenuation
Options
measurements and directly readable field Sweep
Option 04 Occupied bandwidth
strength measurements by means of Sweep time: 50 ms to 1000 s per sweep
Measurement
antenna calibration and is further capable (10 div)
Option 06 Memory card
of quasipeak-value measurements 100s to 1000 s for zero span
Input
conforming to CISPR standards .
Maximum input level : + 30 dBm (1 Watt)
Completely independent digital memories
15 VDC, at 50 f1 or 75 f1 inputs
for two channels enable storage of two
displays each and a versatile complement
of marker functions is provided to increase
measurement speed .
GPIB is provided to enable full remote
control and the use of a synthesized local
oscillator ensures accurate frequency
setting, making the TR4135 usable as a
spectrum analyzer for automated
measuring systems .

Das könnte Ihnen auch gefallen