Sie sind auf Seite 1von 10

Chapter 10

Prestressed Concrete

By Wayne Kassian
Walter Dilger

Presented By:

CONCRETE DESIGN HANDBOOK THIRD EDITION 1

PRESTRESSED CONCRETE
IS A TYPE OF REINFORCED
CONCRETE WHERE THE STEEL
REINFORCEMENT HAS BEEN
TENSIONED AGAINST THE
CONCRETE
SELF EQUILIBRATING SYSTEM OF
INTERNAL STRESSES

TWO DIFFERENT PROCEDURES


FOR PRESTRESSING CONCRETE
Prestressed Concrete (P/C)

Pretensioned P/C Post-Tensioned P/C

1
CREEP
AFTER BEING
PRECOMPRESS
ED, CONCRETE
CONTINUES TO
SHORTEN WITH
TIME

SHRINKAGE
LOSS OF
MOISTURE
WITH TIME
ALSO CASUES
SHORTENING
OF THE
CONCRETE

TO REDUCE LOSSES AND


ACHIEVE HIGHER LEVELS OF
PRECOMPRESSION:
HIGH
STRENGTH
STEEL

HIGH
STRENGTH
CONCRETE

2
PRESTRESSED CONCRETE
PRODUCTS
BRIDGES
BUILDINGS AND PARKING
STRUCTURES
FLOOR AND ROOF SLABS
WALL PANELS
ARCHITECTURAL ELEMENTS
CIRCULAR STORAGE TANKS

PRESTRESSED CONCRETE
CRITERIA IN CSA A23.3-04

CSA A23.3 - CHAPTER 16


PRECAST CONCRETE

INCREASE IN c FOR PRECAST

c = 0.65 FOR MOST CONCRETE


c = 0.70 FOR PRECAST CONCRETE
CERTIFIED IN ACCORDANCE WITH
CSA A23.4

3
PLANT-CONTROLLED
QUALITY CONTROL

10

11

12

4
ONE-WAY FLOOR AND ROOF SLABS
ONE-WAY PRESTRESSED WALL PANELS

NOT EXCEEDING 3660 mm WIDTH


(increased from 3000 mm in previous code)

MINIMUM TRANSVERSE REINFORCEMENT


CAN BE WAIVED

13

14

15

5
16

17

NEW BEARING REQUIREMENTS


DISTANCE FROM EDGE OF
SUPPORT TO END OF PRECAST
MEMBER:
MINIMUM ln/180
HOLLOW CORE OR SOLID SLABS
- 50 mm
BEAMS OR STEMMED MEMBERS
- 75 mm

18

6
BEARING PADS TO BE SET
BACK:
A MINIMUM OF 12 mm

OR THE CHAMFER DIMENSION,


WHICHEVER IS LARGER

19

20

STRUCTURAL INTEGRITY
FOR THE TRANSFER OF
HORIZONTAL LOADS:

DO NOT CONSIDER BENEFICIAL


EFFECTS OF FRICTION CAUSED BY
GRAVITY LOADS

21

7
CHAPTER 18
PRESTRESSED CONCRETE

22

NEW SHEAR PROVISIONS


CHAPTER 11- NEW PROVISIONS

TRADITIONAL Vcw AND Vci NO LONGER


USED

CHAPTER 18- NEW PROVISIONS


REVISED PROVISIONS FOR
PUNCHING SHEAR- TWO WAY SLABS
- ACCOUNTS FOR SIZE AFFECT

23

FLEXURAL RESISTANCE
MEMBERS WITH UNBONDED TENDONS

REVISED EQN (18-2)


USE OVERALL LENGTH lo
fpr = fpe + 8000n(dp - cy)/lo
n(dp - cy) = sum of the distance (dp -
cy) for each of the plastic hinges in
the span

24

8
25

SOFTWARE: CONCISE BEAM


DESIGN OF PRECAST CONCRETE
BEAMS TO A23.3-04

www.blackmint.com
26

HOW TO CONTACT CPCI

Call toll free: 1- 877-YES-CPCI


1- 877-937-2724
WEB: www.cpci.ca
EMAIL: info@cpci.ca

27

9
CHAPTER 10
PRESTRESSED CONCRETE

CLOSING COMMENTS

QUESTIONS?

28

10

Das könnte Ihnen auch gefallen