Sie sind auf Seite 1von 1

The Lincoln Electric Company

22801 St. Clair Avenue CERTIFICATE OF CONFORMANCE


Cleveland, Ohio 44117-1199

Product: Lincolnweld 980 Flux /


Lincolnweld L-50 Electrode
Classification: F7A2-EM13K-H8
Specification: AWS A5.17:1997, ASME SFA-5.17
Date May 20, 2016
This is to certify that the product named above and supplied on the referenced order number is of the same classification, manufacturing process, and material
requirements as the material which was used for the test that was concluded on the date shown, the results of which are shown below. All tests required by the
specifications shown for classification were performed at that time and the material tested met all requirements. It was manufactured and supplied according to
the Quality System Program of the Lincoln Electric Company, Cleveland, Ohio, U.S.A., which meets the requirements of ISO9001, NCA3800, AWS A5.01,
and other specification and Military requirements, as applicable. The Quality System Program has been approved by ASME, ABS, and VdTUV.

F7A2-EM13K-H8
Operating Settings Requirements RESULTS
Electrode Size 162in
5/32 5/321inch
Polarity DC+
Voltage, V 27 - 30 28
Wire Feed Speed, cm/min (in/min) 112 (44)
Current, A 475 - 575 525
Contact Tip to Work Distance, mm (in) (1 - 1.5) 32 (1 1/4)
Travel Speed, cm/min (in/min) (15 - 17) 41 (16)
Pass/Layers 15/7
Preheat Temperature, C (F) (60 - 325) 20 (69)
Interpass Temperature, C (F) (275 - 325) 150 (300)
Postweld Heat Treatment As-welded As-welded
Mechanical properties of weld deposits
Tensile Strength, MPa (ksi) (70 - 95) 540 (78)
Yield Strength, 0.2% Offset, MPa (ksi) (58 min.) 440 (64)
Elongation % 22 min. 31
Average Impact Energy (20 min.) 61 (45)
Joules @ -29 C (ft-lbs @ -20 F) 45,54,84 (34,40,62)
Average Hardness, HRB Not Required 85

Chemical composition of weld deposits (weight %)


C Not Required 0.05
Mn Not Required 1.57
Si Not Required 0.40
S Not Required 0.005
P Not Required 0.018
Cu Not Required 0.11
Electrode composition (weight %) F7A2-EM13K-H8 Electrode
Requirements Results
C 162 0.06 - 0.16 1 0.11
Mn 0.90 - 1.40 1.21
Si 0.35 - 0.75 0.43
S 0.030 max. 0.003
P 0.030 max. 0.008
Cu (Total) 0.35 max. 0.08
F7A2-EM13K-H8
Diffusible Hydrogen (per AWS A4.3) Requirements RESULTS
Electrode Size 162 1 5/32 inch
Polarity DC+
Nominal Voltage, V 28
Nominal Current, A 525
Diffusible Hydrogen, mL/100g 8.0 max. 2.1
Abs. Humidity (gr moisture/lb dry air) 48

1. This certificate complies with the requirements of EN 10204, Type 2.2.


2. The electrode size required to be tested for this classification is 5/32 inch. All other sizes manufactured will also meet these requirements.
3. Radiographic Inspection: Met requirements.
4. Strength values in SI units are reported to the nearest 10 MPa converted from actual data. Preheat and interpass temperature values in SI units are
reported to the nearest 5 degrees.

May 20, 2016 May 26, 2016


Toronto Cunningham, Certification Supervisor Date Marie Quintana, Director, Consumable Date
Compliance

Page 1 of 1 Cert. No. 56500