Beruflich Dokumente
Kultur Dokumente
A25000-A1600-A018-01-76P1 57
Issue: 1 Issue date: November 2010
.
Mechanical structure and interface
. Product Description
Pin # Pair
1 3 (white/green)
2 3 (green)
3 2 (white/orange)
4 2 (orange)
5 1 (white/blue)
6 1 (blue)
7 4 (white/brown)
8 4 (brown)
Ethernet cable
The cable is a double shielded four twisted pairs Cat 5e cable. A 24-valued AWG (min.)
is necessary to minimize cable power loss. Cable materials are designed to meet
outdoor conditions. The cable shield shall be connected to the FlexiPacket MultiRadio
grounding point.
7.1.4.2 PS connector
This connector is used to power supply the FlexiPacket MultiRadio with a dedicated
power supply (-48 Vdc + 20%) cable. In this case the interconnection with an Indoor
Device is implemented with 2 cables.
The PS connector is shown in Figure 32 and described in Table 16. It is a shielded
Amphenol multipolar connector with 2 golden power pins. Each pin can accept at least
13 AWG wire diameter.
58 A25000-A1600-A018-01-76P1
PS cable
The cable is a shielded, two wire cable. A 13-valued AWG (min.) is necessary to
minimize cable power loss; with this value 200m connection is guaranteed over the tem-
perature range -40 to +60C. Cable materials shall be designed to meet outdoor con-
ditions. The cable shield must be connected to the FlexiPacket MultiRadio grounding
point.
Parameters Value
Output voltage range and -0.5V @ Prx = -90 dBm
Received Power range -4.0V @ Prx = -20dBm
Output impedance 100 ohm / 1nF
Nominal sensitivity 0.5V/10dB
Accuracy 3 dB
A25000-A1600-A018-01-76P1 59
Issue: 1 Issue date: November 2010
.
Mechanical structure and interface
. Product Description
Figure 35 PS connector
Signal name
48 V + (Left side pin)
48 V - (Right side pin)
60 A25000-A1600-A018-01-76P1
A25000-A1600-A018-01-76P1 61
Issue: 1 Issue date: November 2010
.
Mechanical structure and interface
. Product Description
62 A25000-A1600-A018-01-76P1
7.2.2.5 LEDs
The Power Injector is equipped with two LEDs for each port:
LED ON (GREEN): input power on and properly working unit
LED FAULT (RED): external fault (cable short-circuit)
During the normal operation green LED ON must be ON.
A25000-A1600-A018-01-76P1 63
Issue: 1 Issue date: November 2010
.
Mechanical structure and interface
. Product Description
64 A25000-A1600-A018-01-76P1
Signal name
48 V + (Left side pin)
48 V - (Right side pin)
A25000-A1600-A018-01-76P1 65
Issue: 1 Issue date: November 2010
.
Mechanical structure and interface
. Product Description
66 A25000-A1600-A018-01-76P1
Figure 42 PS connector
Signal name
48 V + (Right side pin)
48 V - (Left side pin)
A25000-A1600-A018-01-76P1 67
Issue: 1 Issue date: November 2010
.
Mechanical structure and interface
. Product Description
68 A25000-A1600-A018-01-76P1