Sie sind auf Seite 1von 4

ADAPT - STRUCTURAL CONCRETE SOFTWARE SYSTEM

ADAPT-Builder Version 2015 Date: May 15, 2017 Time: 19:10:47 File: Support Line 2
1 - PROJECT TITLE: General name
1.1 Design Strip: Support Line 2
1.2 Load Case: Envelope

2 - MEMBER ELEVATION
[m] 0.000 2.380 11.170 0.000

3 - TOP REBAR

3.1 ADAPT selected 3 5-18mm X2720 mm

3.2 ADAPT selected 1 5-18mm X4660 mm 2 10-18mm X2480 mm

5 - BOTTOM REBAR

5.1 ADAPT selected 5 5-28mm X7000 mm

5.2 ADAPT selected 4 6-28mm X12440 mm

Note: Reinforcement shown on plan may differ from the above schedule. Bars on plan are adjusted in length, and account for spacing requirements of the code

6 - REQUIRED & PROVIDED BARS


max0 876 2414 0
6.1 Top Bars 26E+02
13E+02
[ mm 2] 00E+00
required
provided 17E+02
34E+02
51E+02
68E+02
6.2 Bottom Bars max0 876 6565 0

7 - SHEAR STIRRUPS
7.1 ADAPT selected.
Bar Size # 18 Legs: 2
Spacing [mm]
120 280 300 300 160

7.2 User-selected
Bar Size # Legs:
44E+02
7.3 Required area 33E+02
22E+02
[mm 2/m] 11E+02
00E+00
0. 0. 4103. 0.

10 - DESIGNER'S NOTES
ADAPT - STRUCTURAL CONCRETE SOFTWARE SYSTEM
ADAPT-Builder Version 2015 Date: May 15, 2017 Time: 19:10:47 File: Support Line 1
1 - PROJECT TITLE: General name
1.1 Design Strip: Support Line 1
1.2 Load Case: Envelope

2 - MEMBER ELEVATION
[m] 0.000 13.400 0.000

3 - TOP REBAR

3.1 ADAPT selected

3.2 ADAPT selected 1 12-18mm X2900 mm 2 6-18mm X2900 mm

5 - BOTTOM REBAR

5.1 ADAPT selected 4 6-28mm X9500 mm

5.2 ADAPT selected 3 6-28mm X12040 mm

Note: Reinforcement shown on plan may differ from the above schedule. Bars on plan are adjusted in length, and account for spacing requirements of the code

6 - REQUIRED & PROVIDED BARS


max0 2846 0
6.1 Top Bars 32E+02
[ mm 2] 16E+02
required 00E+00
provided 19E+02
38E+02
57E+02
76E+02
6.2 Bottom Bars max0 7064 0

7 - SHEAR STIRRUPS
7.1 ADAPT selected.
Bar Size # 18 Legs: 2
Spacing [mm]
260 280

7.2 User-selected
Bar Size # Legs:
20E+02
7.3 Required area 15E+02
10E+02
[mm 2/m] 50E+01
00E+00
0. 1890. 0.

10 - DESIGNER'S NOTES
ADAPT - STRUCTURAL CONCRETE SOFTWARE SYSTEM
ADAPT-Builder Version 2015 Date: May 15, 2017 Time: 19:10:47 File: Support Line 3
1 - PROJECT TITLE: General name
1.1 Design Strip: Support Line 3
1.2 Load Case: Envelope

2 - MEMBER ELEVATION
[m] 0.000 13.400 0.000

3 - TOP REBAR

3.1 ADAPT selected

3.2 ADAPT selected 1 12-18mm X2900 mm 2 12-18mm X2900 mm

5 - BOTTOM REBAR

5.1 ADAPT selected 4 7-28mm X8220 mm

5.2 ADAPT selected 3 7-28mm X10760 mm

Note: Reinforcement shown on plan may differ from the above schedule. Bars on plan are adjusted in length, and account for spacing requirements of the code

6 - REQUIRED & PROVIDED BARS


max0 3003 0
6.1 Top Bars 32E+02
16E+02
[ mm 2] 00E+00
required
provided 22E+02
44E+02
66E+02
88E+02
6.2 Bottom Bars max0 8517 0

7 - SHEAR STIRRUPS
7.1 ADAPT selected.
Bar Size # 18 Legs: 2
Spacing [mm]
170 220 220 170

7.2 User-selected
Bar Size # Legs:
32E+02
7.3 Required area 24E+02
16E+02
[mm 2/m] 80E+01
00E+00
0. 2979. 0.

10 - DESIGNER'S NOTES
ADAPT - STRUCTURAL CONCRETE SOFTWARE SYSTEM
ADAPT-Builder Version 2015 Date: May 15, 2017 Time: 19:10:47 File: Support Line 4
1 - PROJECT TITLE: General name
1.1 Design Strip: Support Line 4
1.2 Load Case: Envelope

2 - MEMBER ELEVATION
[m] 0.000 13.400 0.000

3 - TOP REBAR

3.1 ADAPT selected

3.2 ADAPT selected 1 11-18mm X2900 mm 2 11-18mm X2900 mm

5 - BOTTOM REBAR

5.1 ADAPT selected 4 5-28mm X8220 mm

5.2 ADAPT selected 3 5-28mm X10760 mm

Note: Reinforcement shown on plan may differ from the above schedule. Bars on plan are adjusted in length, and account for spacing requirements of the code

6 - REQUIRED & PROVIDED BARS


max0 2758 0
6.1 Top Bars 28E+02
[ mm 2] 14E+02
required 00E+00
provided 16E+02
32E+02
48E+02
64E+02
6.2 Bottom Bars max0 5659 0

7 - SHEAR STIRRUPS
7.1 ADAPT selected.
Bar Size # 18 Legs: 2
Spacing [mm]
190 300 300 190

7.2 User-selected
Bar Size # Legs:
28E+02
7.3 Required area 21E+02
14E+02
[mm 2/m] 70E+01
00E+00
0. 2634. 0.

10 - DESIGNER'S NOTES