Design Ultimate Axial Capacity of Section (T)= A x fa = 422 KN Splice to be Designed for Capacity (Percentage) = 105% So, Ultimate Axial force for Splice Plate Design = 443.1 KN Splice Design Force is taken by one side of angles (F) = 221.55 KN
Design of Splice Plates
Total available width for splice (Bfp) 110-2x10 = 90 mm Thickness of flange splice plate reqd F / (Bfp x fa) = 12.31 mm Flange Splice plate thk provided = 16 mm
Ultimate Strength of Weld (Refer IS:814) = 410 N/mm2
Type of weld = Shop Partial Safety factor of Weld (Refer Table 5 of IS 800) (FS ) = 1.25 Design Ultimate shear strength of weld fuw / sqrt(3) / FS = 189 N/mm2 Size of weld = 8 mm Capacity of weld per unit length 0.707 x 8 x 189 / 100 = 1.071 KN/mm Required total weld length 221.55/1.071 = 206.85 mm Weld Length each side 206.8/2 = 103.42 mm Length of flange splice plates required 2x103.42 = 206.85 mm Length of flange plates Provided = 220 mm