Beruflich Dokumente
Kultur Dokumente
User Interface
Refer to Section 5.32.12 of the STAAD Technical Reference manual for details on generating wind
loads.
If a wind load has not yet been defined for the model, a warning message is displayed in the dialog
and the controls are inactive. Refer to the CreateWindType Definition dialog to learn more about
defining a wind load.
Select Type
Choose a previously defined wind load type from the drop down list.
Exposed Surface and Direction
mk:@MSITStore:C:\SProV8i%20SS6\STAAD\Help\STAADGUI.chm::/dialogs/create_ne... 11/2/2015
Wind Load tab Page 2 of 4
Specify the global direction in which the wind load is to be generated by clicking the X, Z, -X or -Z
radio button. When wind is generated in X direction ,the wind load is applied on the near side &
when -X is chosen the load is applied on the far side as explained in the following figures.
Generation in Z or -Z is similar.
Wind in positive and negative directions
Wind in X Wind in -X
Factor
Specify the factor by which the calculated wind loads will be multiplied.
Open Structure
mk:@MSITStore:C:\SProV8i%20SS6\STAAD\Help\STAADGUI.chm::/dialogs/create_ne... 11/2/2015
Wind Load tab Page 3 of 4
Select this option to generate loads on open structures like highway signs or transmission towers.
By default, the load generation is based on the assumption that the region between members is
covered by panels (i.e., cladding). Setting this option will apply load to only the members (i.e., no
cladding).
The term used here is not the same as the ASCE 7 definition of "open structure."
Please use the ASCE-7 Wind Load dialog box to generate describe the enclosure
classification per this code.
SNiP Parameters
The following parameters are used for wind loads generated per the Russian code (SNiP).
Select Configuration
mk:@MSITStore:C:\SProV8i%20SS6\STAAD\Help\STAADGUI.chm::/dialogs/create_ne... 11/2/2015
Wind Load tab Page 4 of 4
computed value is used instead. For rectangular buildings, the correlation coefficient is always
calculated automatically, thus any specified value will be ignored.
The first load case which has a Russian Wind Load command added to it will consider all other
loads defined in it as the masses to be considered for calculating the dynamic effect which is
required by this command.
Related Tasks
Reference Materials
mk:@MSITStore:C:\SProV8i%20SS6\STAAD\Help\STAADGUI.chm::/dialogs/create_ne... 11/2/2015