Amendments to the

CARES Post Tensioning


Certification Scheme
1 Background Post Tensioning Anchorages must either
comply with BS EN 13391 or have a European
Following on from its certification scheme for Technical Approval to ETAG013.
post tensioning in bridges, CARES introduced Stressing equipment must comply with the
a scheme for flat slabs in 1999, recognising that Post Tensioning kit producers recommendation.
this construction method was on the increase and The Post Tensioning kit must now only be
that controls via certification requirements were supplied by the Post Tensioning contractor.
non-existent. Since its introduction, CARES has This reduces the possibility of the unqualified
received industry feedback relating to particular Post Tensioning kits being installed.
elements of the post tensioning operation. Prestressing Strand and high tensile steel bar
This has resulted in a revision of its scheme must be CARES approved.
requirements in key areas, as described below. All Post Tensioning operatives must now
have a photo-identification card issued
The recent amendments to the scheme addressed by CARES in accordance with the CARES
areas of the construction process recognised as those scheme requirements (CARES Appendix PT9).
requiring improvement. For example, feedback from This reduces the possibility of inexperienced
the industry sector indicated that grouting was an area personnel being used to undertake specialist
that required a more stringent approach, including the Post Tensioning work.
training and qualification of grouting operatives. All Post Tensioning operations are to be carried
It has been reported to CARES that a percentage of out under the control of a nominated supervisor.
ducts, approaching 1% on average, have been either Post Tensioning specifications produced by the
partially or completely ungrouted, thereby potentially Post Tensioning contractor must comply with
affecting the integrity of a number of buildings in the the minimum recommended requirements of
long term. This is an average figure, and recognising the CARES Model Specification.
that risks may result from inadequate grouting Grout must now comply with the new
procedures or from the use of a poorly trained or BS EN 447: 2007.
inadequately supervised grouting team, it is possible Grout must now be pre-bagged, reducing
that this figure will be exceeded in certain structures. the variability due to site batching and the
inherently variable properties of bagged
The amended CARES certification scheme cement.
requirements were implemented in February Grouting operations must only be undertaken
of 2008. within the temperature range specified by the
grout manufacturer.
Grouting records must be recorded and
2 Revision to the CARES Scheme provide confirmation that each duct has been
fully grouted.
The CARES PT scheme is monitored by an across The Post Tensioning contractor must inform
industry CARES Post-tensioning Technical Committee CARES of all contracts to be undertaken
which meets on a regular basis to review scheme and CARES will audit 10% of these contracts
requirements in the light of feedback from industry as a minimum.
sectors and also CARES own auditing experience.
The CARES scheme for flat slabs (PT2) is now at issue Additional related CARES documents
4; amended in November 2007 and implemented in
February 2008. The main changes, at this recent The CARES Model Specification for Bonded
revision, are: and Unbonded Post-tensioned Floors.
Amendments to the
CARES Post Tensioning
Certification Scheme
3 Risks to incorrectly Should such a review raise concerns, in some
post-tensioned buildings cases a selective programme of intrusive or
non-destructive testing may be considered
Recognising the importance of using a post appropriate in addition to the normal cycle of
tensioning contractor with sound grouting procedures visual structural inspections. Currently, research
and properly trained operatives and supervision, in NDT methods is ongoing and the selection of
and considering any risks and their consequences any method requires detailed consideration,
of not doing so, building owners might wish to including assessment of the methods reliability.
perform project specific reviews on existing post Useful guidance is given in fib Bulletin 33,
tensioned buildings. Chapters 3 and Appendix A.

The risks for a building will depend on a number of


factors including: 4 Recommendations
for new buildings
the level of confidence in the installation,
the exposure of the structure to the environment, It is with these risks in mind that the CARES
the sensitivity of the structure should tendon Post Tensioning Scheme has been designed,
loss occur, and it is highly recommended that new buildings
the use of the building. should be constructed by a specialist contractor
certified under the CARES post-tensioning
With specific reference to grouting, the scheme. Bearing in mind however that, unless
consequences of ungrouted or poorly grouted the client specifies that CARES is present on a
tendons may include: specific project, the CARES scheme will include
audits of only a sample of the projects of the
for exposed structures, risk of spalling of concrete specialist post tensioning contractor.
adjacent to ducts primarily due to the presence of With this in mind, project specific start up
trapped water in ungrouted ducts, which would reviews are recommended to ensure that
freeze at sub-zero temperatures. the issues above have been addressed and the
for enclosed structures, latent spalling from roles and responsibilities for quality control are
construction phase, clear and understood.
failure of an ungrouted tendon due to corrosion,
reduced contribution to shear and ULS flexure Should the client wish, CARES may be
capacity due to unbonded behaviour, called to apply its certification scheme on
unpredictable response during demolition any particular structure via, if necessary, the
or modification. contract specification.

Why Take the Risk. Specify CARES.