Beruflich Dokumente
Kultur Dokumente
The powerful injection mortar for rebar connections and cracked concrete.
BUILDING MATERIALS
ADVANTAGES
applications
FUNCTIONING
base Material
IMAGES AND PHOTOS MERELY ILLUSTRATIVES.
INSTALLATION
loads
Injection mortar FIS EM
Ultimate loads for threaded rods only. Embedment
Type
5.8 5.8 5.8 5.8 5.8 5.8
[in]
3 1/2 4 3/8 5 8 3/4 8 1/4 11
non-cracked concrete
fc
temperature range (140F / 95F)
Tension static 2.500 psi Nu [lbs] 5,898 10,800 17,202 25,456 46,105 73,761
8.000 psi Nu [lbs] 5,898 10,800 17,202 25,456 46,105 73,761
Shear static 2.500 psi Vu [lbs] 3,538 6,480 10,321 15,274 27,663 44,256
short term temperature / long term temperature
loads
Injection mortar FIS EM
Allowable loads for threaded rods only.
Embedment
Type
5.8 5.8 5.8 5.8 5.8 5.8
[in]
3 1/2 4 3/8 5 8 3/4 8 1/4 11
non-cracked concrete
fc
temperature range (176F / 122F)
Tension static 2.500 psi Nall [lbs] 2,467 4,517 5,860 9,192 12,421 19,123
8.000 psi Nall [lbs] 2,467 4,517 7,195 10,648 19,284 30,852
Shear static 2.500 psi Vall [lbs] 1,138 2,502 3,985 5,897 10,680 17,087
short term temperature / long term temperature
Strength reduction factor and load conversion factor = 1.48 (30% D and 70% L) are included. Strength reduction factor depends on the failure mode of the anchor.