Sie sind auf Seite 1von 1

2.

1 OPERATING INSTRUCTIONS
Project
Ravina Hospital, Maduravoyal, Chennai REINFORCED CONCRETE COUNCIL ENTER DATA IN BLUE CELLS ONLY.
Client
Ravina Hospitals Made by Date Page RED MESSAGES INDICATE ENTRY ERRORS.
Location
North Boundary RPS 20-Jun-2017 101
RETAINING WALL design to BS 8110:1997, BS 8002:1994. BS 8004:1986 etc.
Checked Revision Job No
Originated from 'RCC62.xls' v2.1 1999-2002 BCA for RCC RPS - R68

IDEALISED STRUCTURE and FORCE DIAGRAMS DESIGN STATUS: VALID

WARNING :
Passive pressure should
only be considered if it
can be guaranteed that
there will be no future
excavation in front of
the wall.

DIMENSIONS (mm)
H= 1600 B= 1100 Tw = 200
Hw = 0 BI = 0 Tb = 200
Hp = 0 BN = 1000 TN = 0
Hn = 0
MATERIAL PROPERTIES
fcu = 25 N/mm gm = 1.5 concrete
fy = 415 N/mm gm = 1.05 steel
cover to tension steel = 50 mm
(0.2 or 0.3 BS8007 specifies crack widths of 0.1 or
Max allowable design surface crack width (W) = 0.3 mm
mm only)
Concrete density = 24 kN/m 0.2 mm.
SOIL PROPERTIES Wall Geometry
Design angle of int'l friction of retained mat'l () = 30 degree
Design cohesion of retained mat'l (C ) = 0 kN/m (Only granular backfil considered, "C" = zero)
Density of retained mat'l (q ) = 20 kN/m
Submerged Density of retained mat'l (qs ) = 5.00 kN/m [default=2/3*q (only apply when Hw13.33
>0) ] =
Design angle of int'l friction of base mat'l (b) = 30 degree ASSUMPTIONS
Design cohesion of base material (Cb ) = 10 kN/m a) Wall friction is zero
Density of base material (qb ) = 10 kN/m b) Minimum active earth pressure = 0.25qH
Allowable gross ground bearing pressure (GBP) = 200 kN/m c) Granular backfill
d)Does not include check of rotational slide/slope failure
LOADINGS Surcharge load -- live (SQK) = 20 kN/m e)Does not include effect of seepage of ground
Surcharge load -- dead (SGK) = 0 water beneath the wall.
Line load -- live (LQK) = 0 kN/m f)Does not include deflection check of wall due to 0.00001
Line load -- dead (LGK) = 0 kN/m lateral earth pressures
Distance of line load from wall (X) = 0 mm h) Design not intended for walls over 3.0 m high
i) Does not include check for temp. or shrinkage effects 8.53
LATERAL FORCES (unfactored) Ka = 0.33 [ default ka = (1-SIN )/(1+SIN )0.33 ] =
Kp = 3.00 [ default kp = (1+SIN b)/(1-SIN b) 3.00
] =
0.5
Kpc = 3.46 [ default kpc = 2kp ] = 3.46
Kac = 1.15 [ 2ka0.5 ]

Force Lever arm Moment about TOE gf Fult Mult


(kN) (m) (kNm) (kN) (kNm)
PE = 8.53 LE = 0.533 4.55 1.40 11.95 6.37
PS(GK) = 0.00 LS = 0.80 0.00 1.40 0.00 0.00
PS(QK) = 10.67 LS = 0.80 8.53 1.60 17.07 13.65
PL(GK) = 0.00 LL = 1.60 0.00 1.40 0.00 0.00
PL(QK) = 0.00 LL = 1.60 0.00 1.60 0.00 0.00
PW = 0.00 LW = 0.00 0.00 1.40 0.00 0.00 REINFORCEMENT DENSITY
Total 19.20 13.08 29.01 20.02 60.2 kg/m
PP = 0.00 (LP-HN) = 0.00 0.00 1.00 0.00 0.00