EASIER TO SERVICE
AuCom has eliminated complex disassembly
to replace or service a part, AuCom MVX
panels are designed with easy rack-in/rack-out
operation, and components are easily accessible
via hinged doors or removable panels while still
keeping unauthorised people out.
MORE FLEXIBILITY
Dont feel constrained in the choice of apparatus
in your switchgear, AuCom panels are compat-
ible with all of the major apparatus suppliers.
2 AUCOM
Internal separation
compartments isolate
bus work during LV
service AuCom keypad and
analog/digital metering
options available Safe LV compartment
Interlocking racking access without need
system for VCBs etc to de-energise MV
section
Easy to
manoeuvre and
install via lifting
eye bolts
Modular design
allows for single
panels or line-ups
RACK-IN/RACK-OUT PHASE
CASSETTES
4 AUCOM
KEYPAD
REAL LANGUAGE
The MVX features simple, plain language MULTILINGUAL CONTROLLER
feedback on the soft starters operation WITH A CHOICE OF EIGHT
LANGUAGES
and events no trip code look-ups.
Choose from English, Chinese, Spanish,
German, Portuguese, French, Italian or
Russian. CLEAR, EASY TO READ SCREEN
General A1
L2 T2
3 Phase Supply To Motor
Supply T2B
E T3B
Control Voltage ............................................................................... 85~275 VAC
Mains Frequency ......................................................................... 45 Hz to 66 Hz A2 A3
Medium Voltage
Low Voltage
C73
Control Supply
Inputs + 10 C74
Bypass contactor
feedback signal
Inputs ................................................................. Active 24 VDC, 8 mA approx. 87~275 VAC
- 15
13 K2
Input B (C63, C64) ..................................................... 24 VDC, 8mA approx. 34 Run output (PFC)
Fibre-optic connections
Outputs RX TX
Relay outputs ............................................................ 10 A at 250 VAC/360 VA C23 43
Bypass Contactor (Terminals 23, 24) .................................. Normally Open Stop C32 52
Programmable output B
Remote Inputs
C41 51
Run Output/ PFC (Terminals 33, 34) .................................. Normally Open Reset C42 64
Output Relay A (Terminals 43, 44) ...................................... Normally Open 62
Output Relay B (Terminals 51, 52, 54) ...................................... Changeover Programmable
C53
61
Programmable output C
Output Relay C (Terminals 61, 62, 64) ...................................... Changeover input A C54
input B C64
Environmental B4 B10
Thermistor
Protection +
4-20 mA
Output
A4 Controller
K1 Main Contactor
K2 Bypass Contactor
6 AUCOM
DIMENSIONS
PHASE CASSETTES
563.2
853 1055
PANELS
2200
1060
1567
1671
Busbar system
Circuit breaker compartment
Shutter
Each panel consists of four compart- Metallic shutters and partitions segregate L-Series panels are designed in compli-
ments: Busbar compartment, cable the compartments from each other. ance with availability classes LSC2B
compartment, circuit breaker compart- When a compartment is opened, all and partition class PM according to IEC
ment and the instrument compartment. other panels in the installation and all 62271-200.
The busbar compartment houses the cable termination compartments (includ-
The switchgear compartments do not
main busbar system, connected to the ing that in the panel concerned) remain
need any tools for opening. Interlocks
fixed upper isolating contacts of the in operation.
allow access only when the correspond-
circuit breaker by means of branch Metallic shutters automatically protect ing high voltage parts are dead and
connections. high voltage components when the earthed.
circuit breaker is withdrawn.
The cable compartment houses the
connection of the power cables to the All switching operations can be per-
busbar. The earthing switch, surge arrest- formed with the doors closed and the
ers, voltage and current transformers can position of the circuit breaker can be
be installed here. seen from the front of the panel through
a pressure-resistant inspection window.
The circuit breaker compartment houses
the bushing insulators containing fixed
contacts for the connection of the circuit
breaker with the busbar and the cable
compartment.
8 AUCOM
ARC FAULT SAFETY
RATINGS
AuCom selects each MVX to suit your STARTER CURRENT RATING
needs. Choose a starter to suit your The full load current rating of the soft
site conditions such as altitude, ambient starter given the parameters detailed in
temperature, load, and starts per hour. the remaining sections of the utilisation
AuCom MVX ratings are detailed using code.
the AC53b utilisation code. An example
is shown below. START CURRENT
165 A: AC-53b 5-30 : 1770
The maximum available start current as a
multiple of FLC.
Off time (seconds)
Start time (seconds) START TIME
The maximum time required to start the
Start current (multiple of FLC)
motor at the rated start current..
Start current rating (amperes)
OFF TIME
The minimum allowable time between
the end of one start and the beginning of
the next start.
10 AUCOM
PROTECTION
Interlock for circuit breaker compartment door Rounded edges guarantee safe handling Swinghandle locks on the doors provide additional safety
12 AUCOM
STARTING AND STOPPING OPTIONS
Current
Current
Current Limit Current Limit Current Limit
Rotor Speed (% Full Speed) Rotor Speed (% Full Speed) Rotor Speed (% Full Speed)
Suitable for most applications. Current Better for generator sets or if conditions Provides a short boost of torque at the
is raised to specified level and held for may vary between starts. beginning of the start.
duration of start.
70%
Motor Speed
70% 70%
Motor Speed
Removes voltage from motor and allows Gradually reduces voltage to extend Provides gradual deceleration to reduce
inertial slowing. deceleration time. fluid hammer.
Make-proof earthing switch USB, Modbus, Profibus, DeviceNet and Ethernet Surge Arresters
communication interfaces
Earth Switch
AUXILIARY MODULES
Vacuum Circuit Breakers
Measurement and protection current
Fuse contactor
transformers
MOVs
Power meters
Apparatus is easily installed by one Protection relays
person using the AuCom service trolley.
RTDs
Equipment is rolled onto the service
Inductive voltage transformers
trolley and rolls into the panel via small
track connectors. Surge protection
Protection relays
14 AUCOM
EQUIPMENT OPTIONS
Indoor support type current transformer and voltage Low duty circuit breaker High duty circuit breaker
transformer
The panel is designed to be equipped Up to a maximum of 6 cables per phase MVX switchgear solutions are equipped
with current transformers for meas- can be used depending on the unit as standard with an advanced vacuum
urement and protective purposes, dimensions and the cable cross-section. circuit breaker which uses three single-
toroidal current transformers and voltage Access to the cables is provided either coil magnetic actuators, one per pole. All
transformers according to the dimensions from the front or from the rear. The switching elements are assembled along
of DIN 42600. For other transformers cables enter the panel from the bottom. a single axis. All mechanical movements
the panel can be adapted on request. Optional top entry design is available. are therefore direct and linear. The
three actuators are mounted in a steel
frame and are mechanically linked by a
synchronising shaft.
2014 AuCom Electronics. As AuCom is continuously improving its products it reserves the right to modify or change the specification of its products at any time
without notice. The text, diagrams, images and any other literary or artistic works appearing in this brochure are protected by copyright. Users may copy some of the
material for their personal reference but may not copy or use material for any other purpose without the prior consent of AuCom Electronics Ltd. AuCom endeavours
to ensure that the information contained in this brochure including images is correct but does not accept any liability for error, omission or differences with the
finished product.