STRUCTURAL NOTES CIHAN

1- GENERAL 3- CONCRETE 4- STEEL REINFORCEMENT TEL5161 308 750 964 :+


Email :cihan.eng13@gmail.com
A. ALL CONCRETE FOR PT SLABS SHALL HAVE A MINIMUM CUBIC CHARACTERISTIC ALL REINFORCING STEEL SHALL BE DEFORMED HOT ROLLED
A.
STRENGTH OF 25 MPA AT 28 DAYS U.N.O. AND A MINIMUM ORDINARY PORTLAND WITH MINIMUM YIELD STRENGTH OF 420 N/SQ. MM AND SHALL BE
A. THE STRUCTURAL DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL B. BARS SPACING:CLEAR DISTANCE BETWEEN BARS SHOULD NOT BE LESS THAN ANY
ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH ANY B. MINIMUM SHRINKAGE AND TEMPERATURE REINFORCEMENT OF APPROVED PROPERTIES Client
OF THE FOLLOWING.
OTHER WRITTEN INSTRUCTIONS THAT MAY BE ISSUED DURING THE COURSE OF THE ARE TO BE ADDED TO CONCRETE OF SLABS TO ENHANCE THE I) 30mm
CONTRACT. SHRINKAGE & TEMPERATURE PROPERTIES OF THIS CONCRETE. OTHER MEANS OF THIS
B. THE CONTRACTOR IS RESPONSIBLE (BUT NOT LIMITED) TO THE FOLLOWING : ENHANCEMENT MAY BE PROPOSED BY THE CONTRACTOR UPON THE APPROVAL OF ii) DIAMETER OF BAR
THE ENGINEER. III) DIA. OF INTERNAL VIBRATION MECHANISM.
1. FULL STRUCTURAL DESIGN OF FLAT SLABS WHICH IS TO BE CARRIED OUT C. APPROVAL FROM THE DESIGN ENGINEER SHALL BE OBTAINED FOR THE C. BENDING AND HOOKING OF BARS:
BASED ON THE DESIGN LOADS (INCLUDING SEISMIC LOADS) AND APPROVED BY THE LOCATION OF ANY CONSTRUCTION JOINTS NOT SHOWN ON THE PLANS. a) STANDARD HOOKS AND BENDING OF BARS SHALL BE IN
ENGINEER PRIOR TO ANY CONSTRUCTION WORKS. D. SUPPORT TO ALL SLAB REINFORCEMENT AT THE CORRECT LEVELS SHALL BE ON ACCORDANCE WITH ACI-315 DETAILING MANUAL. KURDISTAN REGION
2. PREPARATION OF SHOP DRAWINGS AND DETAILS WHICH ARE TO BE SUBMITTED FOR APPROVED BAR CHAIRS SPACED AT MAX. 300MM CENTERLINE TO CENTERLINE
THE ENGINEER APPROVAL PRIOR TO ANY CONSTRUCTION WORKS. b) ALL BARS SHALL BE BEND COLD UNLESS PERMITTED BY -ERBIL-
BOTH WAYS.
3. SUBMISSION OF THE METHOD OF STATEMENT FOR CONSTRUCTION SEQUENCE FOR STRUCTURAL ENGINEER.
E. METHOD OF CURING CONCRETE SHALL BE APPROVED BY THE ENGINEER.
THE ENGINEER APPROVAL PRIOR TO ANY SITE WORKS. c) COLUMN REINFORCEMENT CRANKING SHALL NOT
F. THE MAXIMUM PERMISSIBLE TEMPERATURE OF ANY CONCRETE MIX AT POINT
C. ALL DIMENSIONS SHALL BE VERIFIED ON SITE. IF ANY DISCREPANCIES OCCUR ON THE OF PLACEMENT SHALL BE 30 DEGREES CENTIGRADE. EXCEED A SLOPE OF 1 IN 6 AS PERMITTED BY ACI CODE. Job Title
CONTRACTOR'S DRAWINGS OR BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE G. PRIOR TO THE REMOVAL OF FRAMEWORK, APPROVAL SHALL BE OBTAINED
D. BENDING AND HOOKING OF BARS:
CONTRACTOR SHALL, DURING TENDERING, ASSUME THE MOST STRINGENT. ANY FROM THE ENGINEER. WHERE BACK-PROPPING OF THE SLAB WILL BE REQUIRED,
DISCREPANCY SHALL BE REFERRED TO THE ENGINEER AS SOON AS IDENTIFIED AND BEFORE THE CONTRACTOR SHALL SUBMIT A BACK-PROPPING LAYOUT AND DESIGN TO a) STANDARD HOOKS AND BENDING OF BARS SHALL BE IN
PROCEEDING WITH THE RELATED WORK. THE ENGINEER FOR APPROVAL. WHERE SLABS AND BEAMS ARE TO SUPPORT ACCORDANCE WITH ACI-315 DETAILING MANUAL.
D. ALL DIMENSIONS ON THESE DRAWINGS ARE IN MILLIMETER FOR SECTION AND METER FOR PLANS MASONRY, THE FRAMEWORK AND PROPS MUST BE REMOVED BEFORE b) ALL BARS SHALL BE BEND COLD UNLESS PERMITTED BY
UNLESS NOTED OTHERWISE. COMMENCEMENT OF LAYING OF MASONRY.
STRUCTURAL ENGINEER.
H. CONCRETE MIX DESIGN SHOULD BE SUBMITTED TO THE ENGINEER FOR
E. DURING CONSTRUCTION, THE STRUCTURE SHALL BE MAINTAINED IN A STABLE CONDITION APPROVAL PRIOR TO CONCRETING. c) COLUMN REINFORCEMENT CRANKING SHALL NOT
AND NO PART SHALL SHALL BE OVERSTRESSED.
I. HOT-WEATHER CONCRETING SHOULD BE DONE FOLLOWING BS 8110, CLAUSE EXCEED A SLOPE OF 1 IN 6 AS PERMITTED BY ACI CODE.
6.2.5 AND/OR ACI 301. Land No.
J. COLD-WEATHER PLACEMENT: COMPLY WITH ACI 306.1. E. REBAR SUPPORT:
K. MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS VERTICAL .HORIZONTAL AND SPACERS Land Area
A. STRUCTURAL DESIGN IS MADE IN ACCORDANCE WITH THE
USING STANDARD CYLINDER TEST. CHAIRS SHALL BE PROVIDED IN ORDER TO HOLD FIRMLY THE
PROVISION OF THE COMPOSITE MEMBERS AMERICAN BUILDING CODE FOR
PLAIN CONCRETE : 14 MPa POSITION OF THE PRINCIPAL REINFORCEMENT DURING CONSTRUCTIONS. Built Area
BS EN 1992-1-1 FOR CONCRETE MEMBERS COLUMNS & SHEAR WALLS : 30 MPa
SABLS & BEAMS : 25 MPa F. REINFORCEMENT BELOW GRADE SHALL BE EPOXY COATED UP TO 1M ABOVE GRADE.
BS EN 1997-1-1 FOR FOUNDATION AND PILED FOUNDATION
L. MINIMUM COMPRESSIVE STRENGTH AT DIFFERENT AGES: ALL OTHER REINFORCEMENT SHALL BE NON COATED AND NON CORRODED.
Notes
BS EN 1998-1-1 FOR SEISMIC DESIGN OF TOWERS
3 DAYS 0.4X28 DAYS VALUE 5-DESIGN LOADS
7 DAYS 0.7X28 DAYS VALUE
ACI318-11 BASICALLY USED IN SOFTWARE APPROACHES a) VERTICAL LOADS
M. ALL SLAB SURFACE CONCRETE IN CONTACT WITH SOIL SHOULD
STRUCTURE DESIGNED TO SUPPORT SUPER IMPOSED
BE CONSTRUCTED USING SULPHATE RESISTANT
LIVE LOAD IN ACCORDANCE WITH THE ASCE 7-05 is:
N. ALL ABOVE SURFACE CONCRETE SHOULD BE CONSTRUCTED
* OFFICES, PUBLIC AREA & AUDITORIUM 4.0 KN/m2
USING ORDINARY PORTLAND CEMENT. IT SHALL CONFORM TO
CONCRETE COVER MIN. SHOULD BE NOT LESS THAN EITHER THE ASTM C 150-77 TYPE 1 OR BS 12. * PARKING AREA 7.0 KN/m2
b) HORIZONTAL LOADS
NOMINAL BAR SIZE OR THE VALUE SHOWN BELOW. O. MAXIMUM SLUMP SHALL NOT EXCEED 120 MM AND WATER WIND : 80 MPH (128 KM./HR.) EXPOSURE - B,
(a) SUB SURFACE : FOOTING (BOTTOM)............ 70mm CEMENT RATIO SHOULD NOT EXCEED 0.45 BY WEIGHT AND OCCUPANCY CATEGORY-II (ASCE7-05)
FOOTING (FORMED SIDES)... 50mm UNLESS PERMITTED BY CONSULTANT SITE ENGINEER.
WALL AND SLABS .................... 35mm P. AGGREGATES SHOULD CONFORM TO ASTM C 33-85 / BS. 882.
COLUMN AND BEAMS .......... 40mm (a) COARSE : GRADING SHOULD FALL WITHIN THE LIMITS
TANKS ................... . 40mm PRESCRIBED BY SIZE NO. 67 AGGREGATE NOMINAL
(b) ABOVE SURFACE: WALL AND SLABS ................. 25mm MAXIMUM SIZE =20 MM.
BEAMS........................ .
(b) FINE : GRADING SHOULD FALL WITHIN THE LIMITS
40mm
COLUMN ..................... 40mm Job Type Job No.

STR. 1

Drawing Title
3.1 FOUNDATION SHOULD BE EXECUTED IN ACCORDANCE WITH
RECOMMENDATION OF GEOTECHNICAL INVESTIGATION REPORT , STRUCTURAL NOTES
WHICH IS NEEDED TO BE TAKEN FOR INSTANCE, AN ALLOWABLE
SOIL BEARING CAPACITY OF100 KN/M2 HAS BEEN RECOMMENDED AT -4M DEPTH
FROM EXISTING GRADE LEVEL.
Drawing No. Scale
3.3 THE SITE SHOULD BE CLEANED FROM ALL RANDOM FILL MATERIALS.
THE SITE MUST BE EXCAVATED AND IS TO BE COMPACTED AND BACK FILLED
1
(AS AND WHERE REQUIRED) AS PER THE RECOMMENDATIONS OF SOIL
INVESTIGATION REPORT.
Designed By:
3.4 LEAN CONCRETE SHALL BE USED FOR BLINDING UNDER ALL
SUBSURFACE STRUCTURES AS SPECIFIED. HAYMAN S. AHMED
MINIMUM THICKNESS SHALL BE 10 CM:
Drawing By:

MUSTAFA QABIL HABEEB

Date Checked
9-10-2016 Cihan Office