3.2.

10 Area Requirement




1. Function: Seat of Democracy (elected members), Law making
2. Major Functional Units:
Legislative Assembly Block
Legislative Council Block
Central Hall
Library
Administration Block
Built-up area required with common areas 323985 SFT
3. Future Expansion (50 Years): 20% additional
4. Location Government City

Legislature Abstract Space requirement (Area in SFT)

Circulation area &

Total area
S.No Functional Unit Name No. Of Units Carpet Area in sft common areas in
required in sft
sft 35%

1 Legislative Assembly building 1 80,000 28,000 108,000



2 Legislative Council building 1 53,100 18,585 71,685

3 Central Hall 1 10,000 3,500 13,500
4 Library 1 11,700 4,100 15,800

5 Admin block for Assembly 1 41,150 20,200 73,700


6 Admin block for Council 1 13,000 4,550 17,550

7 Common Facilities Centre 1 17,600 6,150 23,750

Total Built up Area 323,985

Open Land Area Required 809,965

Vehicle Parking Area 178,750
Total Land Area 988,715

Total land required 22.7 ACRES

Capitol Complex 43 | P a g e









No. of Units Area required for Total Area required
SI. No. Functional Unit Name (Quantity) Functions performed in the unit each sub unit in sft for each unit in sft




Assembly Hall including speaker,secretary and other officers 12500 + 2500 (for
seats in the hall,technical section,galleries (VIPs, officers, Double Ht - 250 toilets adjacent to the
1 press,and visitors,server room) Members Assembly Sessions house and at gallery) 15000
Chamber 1600

Ante Room including toilets 300
Peshi (5 Persons) 250
2 Chambers of Hon'ble Speaker 1 Waiting room 600 2750

3 Officer's waiting hall ( for Hon'ble speaker) 1 25 (Persons) 1000 1000
Chamber 1200

Ante Room including toilets 300
4 Chamber of Deputy Speaker 1 Peshi (5 Persons) 1250 1750
Chamber 1600

Ante Room including toilets 300
Peshi (5 Persons) 250
5 Chamber of Hon'ble Chief Minister 1 Waiting room 600 2750

6 Officer's waiting hall ( for Hon'ble Chief Minister) 1 25 (Persons) 1000 1000
Chamber 1600

Ante Room including toilets 300
7 Chambers of Leader of opposition 1 Peshi (5 Persons) 250 2150
Chamber 400
8 Ministers chambers 28 toilet + lobby 100 14000
8 Chamber 400
9 Secretary's chamber (Adjacent to CM's Chamber) toilet + lobby 100 4000
10 Pantry 1 500 500
11 Committee Hall (Big) 1 Meetings 1000 1000
12 Committee Hall (Small) 3 Meetings Each 750 2250

Capitol Complex 44 | P a g e








No. of Units Area required for Total Area required
SI. No. Functional Unit Name (Quantity) Functions performed in the unit each sub unit in sft for each unit in sft

13 Govt.Chief Whip toilet + lobby 100 650
Chamber 300
Peshi (5 Persons) 250
14 Govt.Whip (each) 4 toilet + lobby 100 2600
15 Members lounge & Pantry 1 Lounge & Dining 3000 3000
16 Separate Room for Lady Members 1 Rest Room 2500 2500
two rooms 950
17 Police officers Room for Monitoring Security 1 toilet + lobby 100 1100
Chamber 400
18 Chambers of Chairman to Legislative Committees 25 toilet + Lobby 100 12500
Office 300
19 Accommodation for legislative party offices 6 toilet + Lobby 100 2400

Accomodation for 10 persons 950
20 Chief Marshal Room (Adjacent to House) 1 toilet + lobby 150 1100
21 General toilets for Ladies and Gents 2 toilets 1200 2400
Media Point 2400
toilets + Lobby 100

Open Area for Parking of 4 No of OB
22 Media point (Away From House) 1 Vans 1000 3600
Total Built up Area Required for Assembly (Appox) 80000

Parking for 450 Vehicles @ 250/
vehicle 112500
Parking for CM's Convoy -10
Vehicles 2500
1 (either in the
open Space or as Parking for Speaker's Convoy-3
23 Parking for Vehicles Cellar) Vehicles 750 115750
24 Parking(2 wheeler) 300 parking 6000 6000

Capitol Complex 45 | P a g e











No. of Units Functions performed in the Area required for Total Area required
SI.No. Functional Unit Name (Quantity) unit each Sub unit in sft for each unit in sft




Council Hall including speaker,secretary and other officers 5000 + 2500 (for
seats in the hall, technical section,galleries (VIPs, officers, Double Ht -100 toilets adjacent to the
1 press,and visitors,server room) Members Council Sessions house and at gallery) 7500
Chamber 1600

Ante Room including toilets 300
Peshi 250
2 Chambers of Hon'ble Chairman 1 Waiting room 600 2750
Chamber 1600

Ante Room including toilets 300
Peshi 250
3 Chambers of Hon'ble Chief Minister 1 Waiting room 600 2950
Chamber 1600

4 Chambers of Leader of opposition 1 Ante Room including toilets 300 1900
Chamber 400

5 Ministers chambers 20 Ante Room including toilets 150 11000
Chamber 300

6 Secretary's chamber 3 Ante Room including toilets 150 1350
7 committee hall (Big) 1 Meetings 750 750
8 committee hall (Small) 2 Meetings 600 1200
9 Separate Room to lady Members 1 rest room 1500 1500
10 Members lounge (100 Persons) 1 lounge + toilets 2000 2000
11 officers lounge 1 lounge + toilets 2000 2000

12 canteen for members during session Days 1 Refreshments 1500 1500

13 police officers room for monitoring security surveillance 1 monitoring 500 500

Capitol Complex 46 | P a g e











No. of Units Functions performed in the Area required for Total Area required
SI.No. Functional Unit Name (Quantity) unit each Sub unit in sft for each unit in sft



Chamber 1200

Ante Room including toilets 300
14 Chambers of Deputy Chair Person 1 Peshi 250 1750

Chamber including toilet 400
15 Govt. Chief Whip 1 Peshi 250 650

Chamber including toilet 400
16 Govt. Whip 2 Peshi 250 1300
chambers 400
17 Chambers of chairman to Legislation committees 10 toilets 100 5000
office 300
18 Accommodation for legislative party offices 6 toilets 100 2400
19 Reading Room 1 reading room 1500 1500

20 Chief marshal room {10 Persons) 1 Accommodation 1100 1100
Media point 1800
toilets + Lobby 200

Open Area for Parking of 2 No of
21 Media point (Away From House) 1 OB Vans 500 2500
Total Built up Area 53100

Parking for 450 Vehicles @ 250/
vehicle 50000

Parking for CM's Convoy -10
Vehicles 2500


1 (Either in the Parking for Chairman/
open Space or DY.Chairman/Opposition leader &
22 as Cellar) VIPS's 2500 55000

parking for vehicles 2 wheeler other
23 Departments,Escort,Police,staff 100 parking 2000 2000
Total area for parking 57000

Capitol Complex 47 | P a g e







Area Requirement for Administra1ve Block (Assembly)


Func1ons performed in Area required for Total Area required
Si. No. Func1onal Unit Name No. of Units (Quan1ty) the unit each sub unit in sC for each unit in sC
Chamber with ante &
toiiet 1000
1 Secretary 1 Peshi 250 1250
2 Mee9ng Hail 1 1600 1600
3 Joint Secretaries 3 600 1800
4 Deputy Secretaries 5 600 3000
5 Asst. Secretaries 12 500 6000
6 Asst. Director 1 500 500
7 Chief Marshal 1 600 600
8 Sec9ons 40 600 24000

9 Repor9ng Sec9on consis9ng of 30 Reporters 1 800 800
10 Stores 1 1600 1600
Total Built up Area 41150


Area Requirement for Administra1ve Block (Council


Func1ons performed in Area required for Total Area required
Si. No. Func1onal Unit Name No. of Units (Quan1ty) the unit each sub unit in sD for each unit in sD
Chamber with ante &
toiiet 750
1 Secretary 1 Peshi 250 1000
2 Mee:ng Hail 1 1600 1600
3 Joint Secretaries 1 600 600
4 Deputy Secretaries 1 600 600
5 Asst. Secretaries 4 500 2000
6 Chief Marshal 1 600 600
7 Sec:ons 10 600 6000

8 Repor:ng Sec:on consis:ng of 20 Reporters 1 600 600
Total Built up Area 13000

Capitol Complex 48 | P a g e








Central Hall - Area Requirement


Area required for Total Area
No. of Units Functions performed each sub unit in required for each
SI. No. Functional Unit Name (Quantity) in the unit sft unit in sft

Hall for Joint sessions of Assembly and
1 Council Members 250 Persons 7500
2 Toilets, Pantry etc. 2500 10000
Total Built up Area Required 10000




Area requirement for Library







Total Area
No. of Units Functions performed Area required for required for
SI. No. Functional Unit Name (Quantity) in the unit each sub unit in sft each unit in sft







Stacking area 3000




Reference Area 3000

Computers Areas (For
1 Library Hall 3000 Reference) 3000 9000
2 Librarian Room 600 600
3 Server Room 300 300
4 Periodicals 600 600
5 Discussion Room 600 600
6 Toilets (Ladies & Gents) 600 600
Total Built up Area 11700

Capitol Complex 49 | P a g e







Area requirement for Library





Total Area
No. of Units Functions performed Area required for required for
SI. No. Functional Unit Name (Quantity) in the unit each sub unit in sft each unit in sft

Stacking area 3000



Reference Area 3000

Computers Areas (For
1 Library Hall 3000 Reference) 3000 9000
2 Librarian Room 600 600
3 Server Room 300 300
4 Periodicals 600 600
5 Discussion Room 600 600
6 Toilets (Ladies & Gents) 600 600
Total Built up Area 11700

Capitol Complex 50 | P a g e