MiPower
Power System Software Package
Planning
Analysis
Design
Simulation
Verification
Power Systems
MiPower is armed with robust power system engine in the backend and a lucid top-notch
Windows GUI in the front-end. Approach, technique & methodology employed are field
proven & time-tested. These conforms with standard ANSI, IEEE, IEC and other worldwide
accepted standards. All power system data is centrally maintained with an industry
standard relational database. Core power systems engine includes
Single Phase Load Flow Three Phase Load Flow Short Circuit
Transient Stability Over Current Relay Co-ordination Distance Relay Co-ordination
Voltage Instability Harmonic Analysis Dynamic Stability
Network Reduction Sub-synchronous Resonance Electro-Magnetic Transients
Long Term Load Forecast Line & Cable Parameter Ground Grid Design
MiPower helps in dealing with a wide range of power system problems. Highly intuitive
Graphical User Interface smoothens the learning curve to a great extent. With MiPower,
Power System Engineers can become productive with minimum effort / time and results are
emphatically visible.
Highlights
Highly qualified Several Phd. MTech. ME, BE
Hard Core Power Systems Expertise Dealt with several hundred cases
Experts in Software Technologies Microsoft Certified Professionals
Experience Domain Expertise of 3 to 30+ years
The mission is to provide state-of-the-art power system solutions. PRDC is in the fore-front
in lending its services to Power sector in the form of System Planning & Studies mainly
to the State Electricity Authorities and Utilities.
Central Database
Ground
Manager Batch Mode
Grid Design
Interface
Automatic
SLD
Line & Generation
Cable
Multi-Graph Params
Plotter
PS Engines
E.g. LF, SC,
AutoCAD TRS
Export / Import Control Systems
Long Term Modeler cum
Load Forecast Simulator
Access Levels
Super User
Element Editor
Library Editor
Viewer
Key Features
All IEEE / IEC standard symbols
Real-time Zooming / panning
Single click Database Link
Display of study results with SLD
Dynamic load flow
Creation of Contingencies
Nested Networks
Multi-Layers
Save / Load snapshot
Find a Bus / Node
Element in-service / out-of-service
User configurable base voltages
Dynamic IEEE / IEC switch
Object Z-Order control
Standard Features Integrated database
Multi-document support Invoke any study - LFA, SCS
Context Sensitive Help
Cut / Paste / Undo / Redo and more..
Ortho mode for drawing / moving objects
Dynamic Text fonts
Rotation / Resizing / WYSIWYG Print preview
Print / Plot onto any Windows support printer / plotter
Supported sizes A4 - A0
MiBatch - Text to DB / DB to
MiBatch aids in conversion of plain ASCII data into standard database & vice-versa.
Text
Key Features
Creation of central database
using available plain ASCII
data files
Easy import / export of data in
plain ASCII text
Single click deletion of
obsolete network data from
central database
Aids quick printing of any
standard library
Plotter
Curve Tracing
Superimpose multiple graphs
User defined X - Y axis labels
Device co-ordination using curves
Harmonic Analysis of obtained graphs
Math operations on obtained curves
Use of Symbols for curve identification
Flexible Axis alignment
Provision for modifying data any time
Standard Features
Context Sensitive Help
Fonts & User defined X - Y axis lables
Standard WUSIWYG Print-preview / Print
User defined Background color
Export to AutoCAD
Zoom facility
Standard Features
Multi-document support
Context Sensitive Help
Cut / Paste / Undo / Redo
Ortho mode for drawing / moving objects
Dynamic Text fonts
Rotation / Resizing / WYSIWYG Print preview
Print / Plot onto any Windows support printer / plotter
Feature Highlights
Short Circuit Analysis
ANSI / IEEE standards Multiplication factors for unknown zero and
IEEE Std 141-1986[4] negative -sequence parameters
IEEE C37,010-1979[1] Positive, negative, zero sequence current
IEEE C37.5-1979 [3] & fault-MVA
IEEE C7010-1979 Phase A, B, C current and fault MVA
IEC 363 Peak Asymmetrical current, Fault impedance R/x
IEC 909 ratio
Symmetrical and Asymmetrical faults Post-fault bus voltages, currents and impedance as
Faults with and without impedance seen at the relay positions
Loop, radial systems Breaker fault interrupting capacity selection
Multi islanding User defined Output units
Multi generation Custom reports
Multi cases and contingencies
Open conductor faults
Travelling shunt faults
Fault at all / selected buses sequentially
Fault at selected voltage level/s
Earthing & Zigzag transformers
First cycle and interrupting fault rating
Reactor Sizing
Alerts breaker capacity violation
Motor contribution to faults
HVDC system contribution to faults
Pre-fault voltage condition from the load flow/flat start
Relay co-ordination for radial and mesh Choice of transient/Sub-transient for Fault
networks
ordination
Automatic / Interactive / Manual Primary-
back-up relay pairs generation
calculation
Fault through impedance
Fault on bus/node/Transmission line
Save and retrieval of selected relay pairs Optional inclusion of motor contribution during
Fault calculation is a part of relay co- fault simulation
ordination program Discrimination time calculator
Phase and Earth relay co-ordination L-G, L-L-L, L-L, L-L-G fault simulation
Optimum setting for Motor relays. Hot and Zone 1, zone 2 and zone 3 setting for
cold curves considered distance relays
Extensive relays data base Impedance seen by the relay for faults
Extensive fuse data
Easy interface for adding new relay to library Sample Co-ordinated curve
Graphical co-ordination - Pick, drag and drop
characteristic curves
Verification of existing relay settings
Fault simulation and relay tripping sequence
Text and Graphical Output
Export to Autocad
Thermal curves for each equipment
Option of Voltage initialization by load flow or
flat start
Overload factor, unbalance factor and
discrimination time for each relay
Static Equivalent - bus admittance matrix (Ybus) as seen from the desired nodes
Output for both Ybus and Zbus matrices for the reduced system
Frequency can be varied from a minimum value to a maximum value at user defined step value
Analysis
voltage studies
Highest discharge currents and energy stresses for the
protective equipment
Over voltages caused due to energization of lines,
transformers and shunt elements, during fault inception and
on clearing of faults
Modeling of transmission line, resistor, series reactor, series
capacitor, synchronous machines, induction motors,
transformer with magnetizing component, shunt reactor
(including saturation), shunt capacitor, instantaneous voltage
and current sources, RMS voltage and current sources,
lightning arrestors
Statistical analysis of breaker closing and opening
Symmetrical and asymmetrical faults with fault impedance
Time varying resistor
Impulse voltage/current can be injected at a bus as
disturbance
Facility exists to incorporate user defined filters
Three phase over voltage profiles
Statistical distribution of over voltages
Arrester voltage, current and energy
Current through different equipment
Voltages at different equipment
Calculation
parameters of overhead lines
Calculates the positive, negative and zero sequence
parameters of Under Ground Cables
Single and multi phase configurations
Wide range of user defined frequencies and temperatures
Calculates the mutual impedance between power and
communication lines
Supports 6 circuits for 3 phase line and 3 circuits for 6
phase line
DC line parameter computation
Transposed and untransposed Line parameters
MKS and FPS units
Impedance in Ohms per km or Ohms
Impedance for entire line length or pu per km or pu for the
entire line length
Frequency varied from minimum to maximum value at user
defined step
Cable parameter calculation for both single core and 3 core
cables
Earth return path through ground or through ground and
sheath or through sheath
Thank You
Thank you