DC Link Capacitors

and Snubbers
Power Electronics
Capacitors
Energy sector
DC
DClink
linkcapacitors
capacitors
Type KNG2047 - KNG3047, KNG2048 - KNG3048

APPLICATIONS
Hybrid vehicles
Wind plants
Solar power plants
Electric energy generation from sea waves
Medical equipment
Industrial equipment
Car electronics
Railway and turbines (generator)
Frequency transducer
Elevators
Welders

Features
Used in DC - link circuits, can replace electrolytic capacitor
Low ESR, high ripple current handling capabilities
Low ESL
Self-healing property
Long lifetime
Aluminium case, filled with epoxy resin

SPECIFICATIONS
Capacitance range See table
Capacitance tolerance 10%, on request 5%
Voltage range max 2200 Vdc
Typical tan. d (50 Hz) <5.0E4
Series resistance <3 m/1 kHz
Dielectric Self healing MPP aluminium
case without overpressure
device
Temperature Coefficient -2,3% from -20 to + 70C
Operating temperature -40C to + 70C at Un
-40C to + 85C at 0.7 Un
-40C to + 100C at 0.5 Un
Inductance <70 nH
Test voltage Terminal to terminal = 1.5 Un DC,10s
Terminal to case 3.6kV AC, 2s
Casing material Aluminium
Filling Epoxy resin dry, UL94, V0
Terminals M6, M8 internal threads
M8 screw types bolds
Torque of terminals M6: 5 Nm, M8: 6 Nm
Max. Altitude 4000 m
Max. hot spot temp. 85C
Clim.cat. IEC 68/1 40/70/21
Lifetime expectancy 100.000 hours at Un, 70C
Reference standard IEC 1071, EN 61071

DC link capacitors and snubbers


DC
DClink
linkcapacitors
capacitors
Type KNG2047 - KNG3047, Type KNG2048 - KNG3048

CN Imax S LS DxH P
UNDC [VDC] RS [m] Rth [K/W]
[F] [A] [kA] [kA] [nH] [mm] [mm]
650 30 3.6 10.9 1.3 40 5.1 85x95 32
900 30 3.7 11.1 1.9 60 4.5 85x125 32
900 60 7.1 21.2 1.2 60 4.2 85x142 32
600
1050 60 7.2 21.5 1.3 70 3.9 85x155 32
1280 60 7.1 21.4 1.5 70 2.6 85x185 32
1740 60 7.1 21.4 1.6 80 2.4 85x235 32
460 35 2.3 6.9 1.4 40 5.1 85x95 32
620 35 3.1 9.3 1.9 60 4.5 85x125 32
640 55 4.4 13.4 1.5 60 4.2 85x142 32
700 750 55 4.5 13.5 1.6 70 3.9 85x155 32
920 55 4.6 13.8 1.7 80 2.6 85x185 32
1240 60 4.7 18.8 1.6 80 2.4 85x235 32
1700 65 8.8 26.5 1.3 70 2.1 116x185 50
370 30 2.2 6.6 1.8 40 5.5 85x95 32
480 55 4.0 12.0 1.2 60 4.9 85x142 32
560 55 4.2 12.6 1.3 60 4.0 85x155 32
900
680 55 4.3 12.9 1.3 70 3.2 85x185 32
950 60 5.7 17.1 1.4 70 2.7 85x235 32
1100 50 8.1 24.3 1.3 60 2.5 116x155 50
230 30 2.1 6.3 2.1 40 4.5 85x95 32
320 55 3.3 10.0 1.2 60 2.8 85x142 32
360 55 3.2 10.0 1.2 60 2.6 85x155 32
410 65 3.7 11.0 1.1 45 2.5 85x155 32
1100
420 65 3.7 11.0 1.1 45 2.5 85x155 32
450 60 4.0 10.0 1.1 70 2.4 85x185 32
610 60 5.3 15.9 1.2 70 2.3 85x235 32
760 70 7.4 22.2 1.1 60 1.8 116x155 50
160 35 3.1 9.3 2.1 40 4.1 85x95 32
220 55 3.2 9.6 1.4 60 3.7 85x142 32
250 55 3.5 10.5 1.3 60 3.5 85x155 32
1350
310 55 3.4 10.0 1.3 70 3.2 85x185 32
420 60 3.5 10.5 1.4 70 2.7 85x235 32
530 60 7.2 21.6 1.4 60 2.0 116x155 50
130 30 1.5 4.5 2.3 40 4.2 85x95 32
180 55 3.5 10.5 1.3 50 3.7 85x142 32
220 55 4.0 12.0 1.3 60 3.5 85x155 32
1500
260 55 4.1 12.3 1.4 60 3.2 85x185 32
360 60 3.6 10.8 1.6 70 2.7 85x235 32
460 60 3.1 9.3 1.7 60 2.0 116x155 50
90 30 1.6 4.8 2.5 60 4.6 85x95 32
140 55 2.0 6.0 2.4 70 3.5 85x155 32
1800
240 60 2.9 8.7 1.7 70 2.7 85x235 32
350 50 3.0 9.0 2.0 70 2.0 116x185 50
75 20 0.5 1.5 5.0 60 5.8 85x125 32
90 40 0.5 1.5 2.5 60 4.5 85x185 32
2200
150 40 0.5 1.5 2.5 70 3.3 85x235 32
220 40 0.6 1.8 2.3 70 2.7 116x185 50

DC link capacitors and snubbers


DC
DClink
linkcapacitors
capacitors
Type KNG2047 - KNG3047, Type KNG2048 - KNG3048

Terms and Definitions


UNDC - rated d.c. voltage RS - series resistance
Maximum operating peak voltage of either polarity but of Effective ohmic resistance of the conductor of a capacitor under
non-reversing type waveform for which the capacitor has been specified operating conditions.
designed.
ESR - equivalent series resistance of a capacitor
CN - rated capacitance Effective resistance which, if connected in series with an ideal
Nominal value of capacitance measured at 20C / 100 Hz. capacitor of capacitance value equal to that of the capacitor
in question, would have a power loss equal to active power
Imax - maximum current dissipated in that capacitor under specified operating conditions.
Maximum r.m.s. current for continuous operation.
LS - self inductance
(dU/dt)max - maximum rate of voltage rise The sum of all inductive elements which are contained in a
Maximum permissible repetitive rate of voltage rise of the capacitor.
operational voltage.
amb - ambient temperature
- maximum peak current Temperature measured at a point approximately 0,1 m away and
Maximum repetitive peak current that can occur during 17.5.2011
Dopustni at two-thirds of the height of the capacitor.
continuous operation.
odstopki za
netolerirane
mere - lowest(Dry
DC- link Capacitor operating temperature
- Type)
= C ( dU )
min

do 6 0,1 dt max Lowest temperature of the dielectric at which the capacitor may
be energized.
S - maximum surge
nad 6current
do 30
0,2
Terminal
Peak non-repetitive current induced by switching or any other max - maximum operating temperature
+1
5 -1

disturbance of thenad
system
30
do 100
0,3 which is allowed for a limited number
Highest temperature of the case at which the capacitor may be
of times, for durations shorter than the basic period. operated.
SPECIFICATIONS nad 100 0,5
do 300
35

Rth - range
thermal resistance
Capacitance
The tolerance
Capacitance
100F 2000F
thermal resistance indicates
10%, on request
nad 300
5% by how many degrees the
0,8 s = C ( dU )
dt s
do 1000
Voltagecapacitor
range temperature
700 Vdc at1800the
Vdchotspot rises in relation to the
nad 1000 1,2
do 2000 dissipation
Temperature losses.
Coefficient -2,3% from 20 to + 70C
tan() - tangent ofnadthe loss angle of a capacitor Operating temperature -40C to + 70C at Un
H +1
-1

2000 2
Ratio between equivalent
do 4000 series resistance and the capacitive -40C to + 85C at 0,7Un
reactance of a capacitor at a specified sinusoidal alternating -40C to + 100C at 0,5Un
nad 4000 3
voltage, frequency and temperature. Inductance <70nH
Test voltage Terminal to terminal = 1,5 Un DC, 10s
Terminal to case 3,6kV AC, 2s
tan( )= ESR C = tan( O ) + Rs C Casing material Aluminium
Filling Epoxy resin dry, UL94, V0 16.1.2013
odstopkiTorque of terminals M6: 5Nm, M8: 6Nm
Dopustni
za

mere Max. Altitude 2000m


netolerirane

M12 6 Lifetime expectancy 100 000hours (Un, hotspot = 70C)


Dopustni DIMENSIONS - kng2047, KNG3047 DIMENSIONS - EN
kng2048, KNG3048
35forbidden by Author`s Rights

do17.5.2011 0,1

nad 6 Reference standard IEC 1071, 61071


16

odstopki za 0,2
netolerirane do 30
mere
DC- link Capacitor (Dry - Type) nad 30 0,3
do 6 0,1 do 100
+1
24 - 1

nad 6 0,2 nad 100 0,5


Terminal
do 30
M6 x 8 do 300
+1
5 -1

nad 30 0,3
do 100 nad 300 0,8
do 1000
SPECIFICATIONS
35

nad 100 0,5


do 300 nad 1000 1,2
Capacitance range 100F 2000F do 2000
All transfer to third persons or misusage for unauthrized purposes is strictly

nad 300 0,8


do 1000 Capacitance tolerance 10%, on request 5% nad 2000 2
Screw terminal M
Voltage range 700 Vdc 1800 Vdc Features
do 4000
-0,5
+1

nad 1000 1,2


H

do 2000 Temperature Coefficient -2,3% from 20 to + 70C nad 4000 3


Operating temperature -40C to + 70C at Un
- Used in DC-link circuits, can replace electrolytic capacitor
H +1
-1

nad 2000 2
do 4000 -40C to + 85C at 0,7Un
nad 4000 3
-40C to + 100C at 0,5Un - Low ESR, high ripple current handling capabilities
Inductance <70nH - Low ESL
P

Test voltage Terminal to terminal = 1,5 Un DC, 10s


Terminal to case 3,6kV AC, 2s - Self-healing property
sak prenos tretjim osebam ali uporaba v nedogovorjene namene ni dovoljena po zakonu o avtorski pravici

Casing material Aluminium - Long lifetime


Filling Epoxy resin dry, UL94, V0 - Aluminium case, filled with resin
Torque of terminals M6: 5Nm, M8: 6Nm
Max. Altitude 2000m
M12 Lifetime expectancy 100 000hours (Un, Applications
hotspot = 70C) M12 D
nsfer to third persons or misusage for unauthrized purposes is strictly forbidden by Author`s Rights

16

Reference standard IEC 1071, EN 61071


D
16

- Used in inverters of wind power and solar power


- Transportation: HEV or EV
M6 x 8 - Welders, elevators, motor driver systems

gradivo
Features za ita predpis-standard izdan

- Used in DC-link circuits, can replace electrolytic capacitor


- Low ESR,Zapis:
sprememba KONDENZATOR
high ripple1 current handling
2 3 KNG20xx
capabilities
4 *15647-06*
5 6
4 7 8 9 10
- Low ESL
P

- Self-healing
t.sprem. property
- Long lifetime
- Aluminium
datum case, filled with resin

DC link capacitors and snubbers


podpis
Applications
C0_RAK001_0201

D - Used in invertersdatum podpis and naziv


of wind power solar power
identifikacijska tevilka

15647-06
- Transportation: HEV or EV
9.11.10
Capacitor KNG20xx
- Welders,
izdelal elevators, motor driver systems
gradivo zaita predpis-standard izdan
odobril 9.11.10 travs B. merilo stran
gradivo za ita predpis-standard izdan
stand. 9.11.10 travs M. sprememba 1 2 3 4 5 6 1:2 7 8 9 1+ 10
t.sprem.
DC
DClink
linkcapacitors
capacitors
Type KNG1910 , Type KNG1914

APPLICATIONS
Hybrid vehicles
Wind plants
Solar power plants
Electric energy generation from sea waves
Medical equipment
Industrial equipment
Car electronics
Railway and turbines (generators)
Frequency inverters
DC filtering applications

FeaTURES
High capacitance
Self-healing properties
High reliability
Low losses
Low dissipation factor of dielectric

CHARACTERISTICS
Rated capacitance: 1 F to 100 F
Capacitance tolerance: 5%, 10%
Rated voltage: 450 V DC, 700 V DC, 900 V DC, 1100 V DC
Operating temperature
range: - 40 C to 85 C
Climatic category: 40/085/56 according to IEC 60068-1
Life expectancy: 100.000 hours at Un
Rated temperature: 85 C
Max. operating
temperature (case): 105 C

REFERENCE STANDARD
IEC 61071

DC link capacitors and snubbers


DC
DClink
linkcapacitors
capacitors
Dimensional data

Ur at 85C = 450V DC, Uop at 70C = 500V DC, Uop at 105C = 300V DC Ur at 85C = 700V DC, Uop at 70C = 800V DC, Uop at 105C = 500V DC
C DIMENSIONS (mm) P P1 d C DIMENSIONS (mm) P P1 d
( F) L H W (mm) (mm) (mm)
( F) L H W (mm) (mm) (mm)
25 42 43 28 37.5 10.2 1 or 1.2
1 32 19 10 27.5 - 0.8
30 42 45 30 37.5 10.2 or 20.3 1 or 1.2
2 32 19 10 27.5 - 0.8
35(10%) 42 45 30 37.5 10.2 or 20.3 1 or 1.2
3 32 19 10 27.5 - 0.8
40 57.5 45 30 52.5 20.3 1.2
4 32 21 12 27.5 - 0.8
45 57.5 45 30 52.5 20.3 1.2
5 32 22 13 27.5 - 0.8
50 57.5 45 30 52.5 20.3 1.2
6 32 24.5 15 27.5 - 0.8
55 57.5 50 35 52.5 20.3 1.2
7 32 24.5 15 27.5 - 0.8
60 57.5 50 35 52.5 20.3 1.2
8 32 26.5 17 27.5 - 0.8
65 57.5 50 35 52.5 20.3 1.2
9 32 28 18 27.5 - 0.8
75(10%) 57.5 50 35 52.5 20.3 1.2
10 32 28 18 27.5 - 0.8
75 57.5 55 40 52.5 20.3 1.2
12 32 32 18 27.5 - 0.8
Ur at 85C = 900V DC, Uop at 70C = 1100V DC, Uop at 105C = 650V DC
14 32 33 20 27.5 - 0.8
15 32 35 20 27.5 - 0.8 C DIMENSIONS (mm) P P1 d

20 32 40 25 27.5 - 0.8 ( F) L H W (mm) (mm) (mm)

22 32 40 25 27.5 - 0.8 1 32 19 10 27.5 - 0.8

12 42 27 16 37.5 - 1 or 1.2 2 32 21 12 27.5 - 0.8

15 42 31 18 37.5 10.2 1 or 1.2 3 32 24.5 15 27.5 - 0.8

22 42 38 21 37.5 10.2 1 or 1.2 4 32 26.5 17 27.5 - 0.8

25 42 38 21 37.5 10.2 1 or 1.2 5 32 28 18 27.5 - 0.8

35 42 43 28 37.5 10.2 1 or 1.2 6 32 33 20 27.5 - 0.8

40 42 45 30 37.5 10.2 or 20.3 1 or 1.2 7 32 33 20 27.5 - 0.8

50 57.5 45 30 52.5 20.3 1.2 5 42 27 16 37.5 - 0.8

55 57.5 45 30 52.5 20.3 1.2 8 42 31 18 37.5 10.2 1 or 1.2

60 57.5 45 30 52.5 20.3 1.2 12 42 38 21 37.5 10.2 1 or 1.2

75 57.5 50 35 52.5 20.3 1.2 15 42 43 28 37.5 10.2 1 or 1.2

80 57.5 50 35 52.5 20.3 1.2 20 42 45 30 37.5 10.2 or 20.3 1 or 1.2

85 57.5 50 35 52.5 20.3 1.2 25 57.5 45 30 52.5 20.3 1.2

100 57.5 55 40 52.5 20.3 1.2 30 57.5 45 30 52.5 20.3 1.2

Ur at 85C = 700V DC, Uop at 70C = 800V DC, Uop at 105C = 500V DC 35 57.5 50 35 52.5 20.3 1.2
40 57.5 50 35 52.5 20.3 1.2
C DIMENSIONS (mm) P P1 d
50(10%) 57.5 50 35 52.5 20.3 1.2
( F) L H W (mm) (mm) (mm)
50 57.5 55 40 52.5 20.3 1.2
1 32 19 10 27.5 - 0.8
Ur at 85C = 1100V DC, Uop at 70C = 1350V DC, Uop at 105C = 800V DC
2 32 19 10 27.5 - 0.8
3 32 21 12 27.5 - 0.8 C DIMENSIONS (mm) P P1 d

4 32 22 13 27.5 - 0.8 ( F) L H W (mm) (mm) (mm)

5 32 24.5 15 27.5 - 0.8 1 32 19 10 27.5 - 0.8

6 32 26.5 17 27.5 - 0.8 2 32 24.5 15 27.5 - 0.8

7 32 28 18 27.5 - 0.8 3 32 28 18 27.5 - 0.8

8 32 28 18 27.5 - 0.8 4 32 32 18 27.5 - 0.8

9 32 32 18 27.5 - 0.8 5 32 33 20 27.5 - 0.8

10 32 33 20 27.5 - 0.8 5 42 31 18 37.5 10.2 1 or 1.2

12 32 35 20 27.5 - 0.8 8 42 38 21 37.5 10.2 1 or 1.2

15 32 40 25 27.5 - 1 or 1.2 12 42 43 28 37.5 10.2 1 or 1.2

8 42 27 16 37.5 - 1 or 1.2 14 42 45 30 37.5 10.2 or 20.3 1 or 1.2

12 42 31 18 37.5 10.2 1 or 1.2 20 57.5 45 30 52.5 20.3 1.2

15 42 38 21 37.5 10.2 1 or 1.2 25 57.5 50 35 52.5 20.3 1.2

20 42 40 21 37.5 10.2 1 or 1.2 27 57.5 50 35 52.5 20.3 1.2

DC link capacitors and snubbers


DC
DClink
linkcapacitors
capacitors
Applications and dimensions

WIND PLANTS
FREQUENCY INVERTERS

DC/AC
inverter
DC/AC
inverter

SOLAR POWER PLANTS

DC (AC)/AC (DC)
inverter
DC (AC)/AC (DC)
inverter
WELDING EQUIPMENT
DC (AC)/AC (DC)
inverter

HYBRID VEHICLES

UPS SYSTEMS
DIMENSIONS

DC link capacitors and snubbers


DC
DClink
linkcapacitors
capacitors
Construction, cautions and warnings

CONSTRUCTION Internal construction:


Dielectric: Polypropylene film
Capacitor electrodes:
Vacuum deposited
Casing: Plastic case with
epoxy resin sealing
flame retardant (UL94 V-0)
Terminal: Parallel tinned copper,
2 and 4 pins

Cautions and Warnings:


Mechanical overloads

Attention: The capacitor is designed for mounting on a PC board. After it has been soldered to the PC board do not move
the capacitor. The capacitor shall not be mounted on places where vibrations or accelerations occur. Do not exceed the
tested ability to withstand vibration. Avoid any compressive, tensile or flexural stress.

Note: Movement of the capacitor within the case can cause low insulation resistance,
shorts, failure on terminals and the capacitor case.

Overload

Attention: Do not overload the capacitor. Avoid overload of the capacitor and consider the flammability of materials.

Impulses

Attention: If electric energy impulses are higher, dielectric breaks down. Avoid external electric energy impulse.
The peak voltage (Up, AC) shall not be higher than the rated DC voltage (UN, DC).

Environmental conditions

Attention: Do not exceed operating temperature. Do not expose the capacitor to humidity longer than it is recommended.
Do not expose the capacitor to increased temperature more than it is recommended.
The dissipation factor may change up and down with increased temperature. Avoid external fire or electricity.

Note: If the capacitor is exposed to humidity longer than it is recommended, the insulation resistance can occur. The place around the
capacitor units must have good air circulation.

DC link capacitors and snubbers


Snubber
DC link capacitors
Type KNO19Ax, KNO19Bx, Type KNO1910, KNO1914

APPLICATIONS
Snubber capacitors are used in applications where high
pulse loadings and high frequencies are presented. Purpose
of snubber capacitors is to eliminate voltage spikes which
are caused by semiconductors or other devices.

IGBT (Insulated Gate Bipolar Transistor)
module
AC and DC converter and inverter
(Electric drives)
Uninterruptable power system (UPS)
Power supply

Features
High voltage
High pulse load capability
Self-healing properties
High reliabilty
Low self-inductance
Low dissipation factor of dielectric
Terminal options for direct mount or board
High insulation resistance

CHARACTERISTICS
Rated capacitance: 0.047F - 8F
Capacitance tolerance: 5%, 10%
Rated voltage: 630 V DC, 850 V DC, 1000 V DC, 1200 V DC,
1600 V DC, 2000 V DC, 2500 V DC,
3000 V DC
Operating temeperature range: -40C to 85C
Climatic category: 40/85/56 according to IEC 60068
Maximum application temperature: 85C
Dissipation factors at 1kHz: tg 5 x 10-4
Test voltage terminal to terminal: 1.5 x Ur, 10s
Peak non - repetitive max current: Ipkr x 1.5
Life expectancy: 100,000 hours at Ur


REFERENCE STANDARD
IEC 61071

DC link capacitors and snubbers


Snubber
DC link capacitors
DC voltages and rated capacitance

DC voltages and rated capacitance

Double side metallized plastic film with internal series connection


U (V DC) C (F)
630 0.33 - 8
850 0.22 - 5.6
1000 0.22 - 4
1200 0.15 - 3.3
1600 0.1 - 3.0
2000 0.1 - 1.5
2500 0.1 - 1.2
3000 0.047 - 1

GENERAL CHARACTERISTICS:
Type KNO19Axx, KNO19Bxx, KNO1910, KNO1914
C Ur Urms du/dt DIMENSIONS C Ur Urms du/dt DIMENSIONS
( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W ( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W
0.33 630 400 max. 600 32 x 20 x 11 0.22 850 500 max. 600 32 x 20 x 11
0.39 630 400 max. 600 32 x 24.5 x 15 0.27 850 500 max. 600 32 x 24.5 x 15
0.47 630 400 max. 600 32 x 24.5 x 15 0.33 850 500 max. 600 32 x 24.5 x 15
0.56 630 400 max. 600 41.5 x 23 x 14 0.39 850 500 max. 600 41.5 x 23 x 14
0.68 630 400 max. 600 41.5 x 23 x 14 0.47 850 500 max. 600 41.5 x 23 x 14
1 630 400 max. 500 41.5 x 27 x 16 0.56 850 500 max. 600 41.5 x 27 x 16
1.2 630 400 max. 500 41.5 x 31 x 18 0.68 850 500 max. 600 41.5 x 27 x 16
1.5 630 400 max. 500 41.5 x 31 x 18 0.82 850 500 max. 600 41.5 x 31 x 18
2 630 400 max. 500 41.5 x 38 x 21 1 850 500 max. 600 41.5 x 31 x 18
2.2 630 400 max. 500 41.5 x 38 x 21 1.2 850 500 max. 500 41.5 x 38 x 21
2.5 630 400 max. 400 41.5 x 43 x 28 1.5 850 500 max. 500 41.5 x 38 x 21
2.7 630 400 max. 400 41.5 x 43 x 28 1.8 850 500 max. 500 41.5 x 43 x 28
3 630 400 max. 400 41.5 x 43 x 28 2 850 500 max. 500 41.5 x 43 x 28
3.3 630 400 max. 400 41.5 x 43 x 28 2.2 850 500 max. 500 42 x 45 x 30
3.5 630 400 max. 400 41.5 x 43 x 28 2.5 850 500 max. 500 42 x 45 x 30
4 630 400 max. 300 42 x 45 x 30 2.7 850 500 max.400 42 x 45 x 30
4.7 630 400 max. 300 57.5 x 45 x 30 3 850 500 max.400 57.5 x 45 x 30
5 630 400 max. 300 57.5 x 45 x 30 3.3 850 500 max.400 57.5 x 45 x 30
5.6 630 400 max. 300 57.5 x 45 x 30 4 850 500 max.400 57.5 x 45 x 30
6 630 400 max. 300 57.5 x 45 x 30 4.7 850 500 max.400 57.5 x 50 x 35
6.3 630 400 max. 300 57.5 x 50 x 35 5.6 850 500 max.300 57.5 x 50 x 35
7 630 400 max. 100 57.5 x 50 x 35
8 630 400 max. 100 57.5 x 50 x 35

10

DC link capacitors and snubbers


Snubber
DC link capacitors
DC voltages and rated capacitance

C Ur Urms du/dt DIMENSIONS C Ur Urms du/dt DIMENSIONS


( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W ( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W
0.22 1000 600 max. 1000 32 x 24.5 x 15 0.15 1200 630 max. 800 32 x 20 x 11
0.27 1000 600 max. 1000 32 x 24.5 x 15 0.22 1200 630 max. 800 41.5 x 23 x 14
0.33 1000 600 max. 900 32 x 24.5 x 15 0.27 1200 630 max. 800 41.5 x 23 x 14
0.33 1000 600 max. 900 41.5 x 23 x 14 0.33 1200 630 max. 700 41.5 x 27 x 16
0.39 1000 600 max. 900 41.5 x 23 x 14 0.39 1200 630 max. 700 41.5 x 27 x 16
0.47 1000 600 max. 900 41.5 x 27 x 16 0.47 1200 630 max. 700 41.5 x 31 x 18
0.56 1000 600 max. 900 41.5 x 27 x 16 0.56 1200 630 max. 700 41.5 x 32 x 19
0.68 1000 600 max. 900 41.5 x 31 x 18 0.68 1200 630 max. 700 41.5 x 38 x 21
0.82 1000 600 max. 500 41.5 x 32 x 19
0.82 1200 630 max. 700 41.5 x 38 x 21
1 1000 600 max. 500 41.5 x 38 x 21
1 1200 630 max. 500 41.5 x 43 x 28
1.2 1000 600 max. 400 41.5 x 38 x 21
1.2 1200 630 max. 500 41.5 x 43 x 28
1.5 1000 600 max. 400 41.5 x 43 x 28
1.5 1200 630 max. 500 42 x 45 x 30
1.8 1000 600 max. 400 42 x 45 x 30
2 1000 600 max. 400 42 x 45 x 30 1.8 1200 630 max. 500 43 x 48 x 33
2.2 1000 600 max. 400 42 x 45 x 30 2 1200 630 max. 500 57.5 x 45 x 30
2.5 1000 600 max. 400 57.5 x 45 x 30 2.2 1200 630 max. 500 57.5 x 45 x 30
2.7 1000 600 max. 400 43 x 48 x 33 2.5 1200 630 max. 500 57.5 x 50 x 35
2.7 1000 600 max. 400 57.5 x 45 x 30 2.7 1200 630 max. 500 57.5 x 50 x 35
3 1000 600 max. 400 57.5 x 45 x 30 3 1200 630 max. 500 57.5 x 50 x 35
3.3 1000 600 max. 400 57.5 x 50 x 35 3.3 1200 630 max. 500 57.5 x 50 x 35
4 1000 600 max. 300 57.5 x 50 x 35

C Ur Urms du/dt DIMENSIONS C Ur Urms du/dt DIMENSIONS


( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W ( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W
0.1 1600 650 max. 900 32 x 20 x 11 0.1 2000 700 max. 1000 32 x 24.5 x 15
0.12 1600 650 max. 900 32 x 24.5 x 15 0.1 2000 700 max. 1000 41.5 x 23 x 14
0.15 1600 650 max. 900 41.5 x 23 x 14 0.12 2000 700 max. 1000 41.5 x 23 x 14
0.22 1600 650 max. 900 41.5 x 23 x 14 0.15 2000 700 max. 1000 41.5 x 23 x 14
0.27 1600 650 max. 700 41.5 x 27 x 16 0.22 2000 700 max. 900 41.5 x 27 x 16
0.33 1600 650 max. 700 41.5 x 27 x 16 0.27 2000 700 max. 900 41.5 x 31 x 18
0.39 1600 650 max. 700 41.5 x 31 x 18
0.33 2000 700 max. 900 41.5 x 32 x 19
0.47 1600 650 max. 700 41.5 x 32 x 19
0.39 2000 700 max. 900 41.5 x 38 x 21
0.56 1600 650 max. 700 41.5 x 38 x 21
0.47 2000 700 max. 900 41.5 x 38 x 21
0.68 1600 650 max. 700 41.5 x 38 x 21
0.56 2000 700 max. 900 41.5 x 43 x 28
0.75 1600 650 max. 700 41.5 x 43 x 28
0.82 1600 650 max. 700 41.5 x 43 x 28 0.68 2000 700 max. 900 41.5 x 43 x 28
1 1600 650 max. 700 41.5 x 43 x 28 0.82 2000 700 max. 600 42 x 45 x 30
1.2 1600 650 max. 700 57.5 x 45 x 30 1 2000 700 max. 700 42 x 45 x 35
1.5 1600 650 max. 700 57.5 x 45 x 30 1 2000 700 max. 600 57.5 x 45 x 30
2 1600 650 max. 500 57.5 x 45 x 30 1.2 2000 700 max. 600 57.5 x 45 x 30
2.2 1600 650 max. 500 57.5 x 50 x 35 1.5 2000 700 max. 600 57.5 x 50 x 35
2.5 1600 650 max. 400 57.5 x 50 x 35
3 1600 650 max. 400 57.5 x 55 x 40

C Ur Urms du/dt DIMENSIONS C Ur Urms du/dt DIMENSIONS


( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W ( F) ( Vdc) ( Vac) ( V/s) (mm) L x H x W
0.1 2500 725 max. 1100 41,5 x 27 x 16 0.047 3000 750 max. 1600 41,5 x 23 x 14
0.15 2500 725 max. 1100 41,5 x 31 x 18 0.068 3000 750 max. 1600 41,5 x 27 x 16
0.22 2500 725 max. 1100 41,5 x 38 x 21 0.1 3000 750 max. 1600 41,5 x 27 x 16
0.33 2500 725 max. 1100 41,5 x 43 x 28 0.15 3000 750 max. 1600 41,5 x 32 x 19
0.47 2500 725 max. 1100 42 x 45 x 30 0.22 3000 750 max. 1600 41,5 x 38 x 21
0.56 2500 725 max. 1000 57,5 x 45 x 30 0.33 3000 750 max. 1400 42 x 45 x 30
0.68 2500 725 max. 1000 57,5 x 45 x 30 0.47 3000 750 max. 1400 57,5 x 45 x 30
0.82 2500 725 max. 1000 57,5 x 45 x 30 0.68 3000 750 max. 1200 57,5 x 50 x 35
1 2500 725 max. 900 57,5 x 50 x 35
0.82 3000 750 max. 900 57,5 x 51 x 35
1.2 2500 725 max. 900 57,5 x 55 x 40
1 3000 750 max. 900 57,5 x 55 x 40
11

DC link capacitors and snubbers


Snubber
DC link capacitors
Dimensions

Version:
KNO19A0
KNO19A1 Version:
KNO19A4 KNO19A2

Version:
KNO19B0
Version: KNO19B1
KNO19A3 KNO19B3
KNO19B5

Version: Version:
KNO19B2 KNO19B4

Lug dimensions
Version L (mm) P (mm) P1 (mm) Screw Version L (mm) P (mm) P1 (mm) Screw
A0 41,5 24 10 M6 B0 41,5 24 10 M6
A0 42 24 10 M6 B0 42 24 10 M6
A0 57,5 37 23 M6 B0 43 25 11 M6
A1 57,5 25 11 M6 B0 57,5 37 23 M6
A2 57,5 46 31 M8 B1 57,5 25 11 M6
A3 41,5 37 18 M6 B2 57,5 37 23 M8
A4 41,5 22 8 M6 B3 57,5 22 8 M6
B4 41,5 37 18 M8
B5 41,5 22 8 M6

12

DC link capacitors and snubbers


Snubber
DC link capacitors
Dimensions, construction and mounting

2 pins. 4 pins 32 27.5 10.2 0.8


Version L (mm) P (mm) P1 (mm) d (mm) 41.5 37.5 10.2 or 1 or 1.2
20.3
32 27.5 / 0.8
14 42 37.5 10.2 or 1 or 1.2
41.5 37.5 / 1 or 1.2
10 20.3
42 37.5 / 1 or 1.2
57.5 50.5 20.3 1.2
57.5 50.5 / 1.2

Construction

Dielectric: Polypropylene film


Capacitor electrodes:Vacuum deposited metal layers
Casing: Plastic case with epoxy resin sealing - flame retardant (UL 94 V -0)
Terminals: Tinned lugs from brass, copper or parallel tinned copper wire with 2 or 4 executions

INTERNAL CONSTRUCTION

Double sided metallized plastic


film with internal series
connection and metallized
plastic film

MOUNTING

fixing lugs
for
M6 or M8 screws

HORIZONTALLY MOUNTED VERTICALLY MOUNTED


13

DC link capacitors and snubbers


Snubber
DC link capacitors
Mounting and applications

Parallel tinned copper wire


2 pins 4 pins

P P1
P

WIND PLANTS
FREQUENCY INVERTERS

DC/AC
inverter
DC/AC
inverter

SOLAR POWER PLANTS

DC (AC)/AC (DC)
inverter
DC (AC)/AC (DC)
inverter
WELDING EQUIPMENT
DC (AC)/AC (DC)
inverter

IGBT module
HYBRID VEHICLES

UPS SYSTEMS

14

DC link capacitors and snubbers


Snubber
DC link capacitors
Cautions and warnings

Cautions and Warnings

Mechanical overloads

Attention: The capacitor is designed for mounting on a PC board. After it has been soldered to the PC board do not move the
capacitor. The capacitor shall not be mounted on places where vibrations or accelerations occur. Do not exceed the tested ability
to withstand vibration. Avoid any compressive, tensile or flexural stress.

Note: Movement of the capacitor within the case can cause low insulation resistance,
shorts, failure on terminals and the capacitor case.

Overload

Attention: Do not overload the capacitor. Avoid overload of the capacitor and consider the flammability of materials.

Impulses

Attention: If electric energy impulses are higher, dielectric breaks down. Avoid external electric energy impulse.
The peak voltage (Up, AC) shall not be higher than the rated DC voltage (UN, DC).

Environmental conditions

Attention: Do not exceed operating temperature. Do not expose the capacitor to humidity longer than it is recommended. Do not
expose the capacitor to increased temperature more than it is recommended.
The dissipation factor may change up and down with increased temperature. Avoid external fire or electricity.

Note: If the capacitor is exposed to humidity longer than it is recommended, the insulation resistance can occur. The place around the
capacitor units must have good air circulation.

15

DC link capacitors and snubbers


PowerDC
electronics capacitors
link capacitors
KNI5048, KNI5015

APPLICATIONS
Metallized polypropylene AC and DC capacitors are used
for power electronics application with high current and
harmonics distortion with long expected life.

Inverter
Filtering
Switching

Features
AC/DC voltage
Self-healing properties
High reliabilty
Cylindrical aluminium case with plastic
self-extinguishing sealing cover
Overpressure disconector
Double tags or screw type bolts

CHARACTERISTICS
Rated capacitance 5F - 500F
Capacitance tolerance 5%, 10%
Rated AC voltage (Urms) 250 VAC, 330 VAC, 480 VAC
Climatic category 40/070/56 according to IEC 60068
Operating temperature range (case) -40C to +85C
Dissipation factors at 1 kHz tg 10 x 10-4 at 100 Hz
Test voltage terminal to terminal 1.65 x Urms, 2s
Test voltage (terminal to case) 3kV, 50Hz, 2s
Max. torque (terminal) M6 - 5 Nm; M8 - 6 Nm; M10 - 10 Nm
Life expectancy 30.000 hours at Urms
Failure quota <300x10-9 components hour

Reference standard IEC 61071

Construction
Dielectric: polypropylene film
Capacitor electrodes:vacum deposited metal layers
Casing: cylindrical aluminium case with plastic self-extinguishing sealing cover
Terminals: tinned steel double tags or tinned brass screw type bolts

16

Power electronics capacitors


PowerDC
electronics capacitors
link capacitors
KNI5048, KNI5015

INTERNAL CONSTRUCTION

TERMINATIONS

Figure 1 Figure 2 Figure 3


KNI5048 KNI5048 KNI5015
45mm to 75mm 85mm 40mm to 55mm

17

Power electronics capacitors


PowerDC
electronics capacitors
link capacitors
Dimensions and applications

Dimensions

C Urms Un Irms du/dt H H1 M M1


P (mm) L (mm) Figure
( F) ( VAC) ( VDC) ( A) ( V/s) (mm) (mm) (mm) (mm) (mm)

25 250 400 12 25 40 75 / / / 8 12 3
50 250 400 25 25 60 80 25 6 22 12 12 1
100 250 400 25 25 60 105 25 6 22 12 12 1
133 250 400 25 25 60 130 25 6 22 12 12 1
200 250 400 25 8 60 155 25 6 22 12 12 1

200 330 600 50 14 85 200 24 8 35 12 16 2


250 330 600 50 12 85 200 24 8 35 12 16 2

100 480 850 50 19 85 175 24 8 35 12 16 2


150 480 850 50 19 85 200 24 8 35 12 16 2

Use of power electronics capacitors

WIND PLANTS
FREQUENCY INVERTERS

DC/AC
inverter
DC/AC
inverter

SOLAR POWER PLANTS

DC (AC)/AC (DC)
inverter
DC (AC)/AC (DC)
inverter
WELDING EQUIPMENT
DC (AC)/AC (DC)
inverter

IGBT module
HYBRID VEHICLES

UPS SYSTEMS

18

Power electronics capacitors


PowerDC
Electronics Capacitors
link capacitors
Cautions and warnings

Cautions and Warnings

Attention: In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not be used at all. This
applies also in cases of leakage. To ensure the full functionality of the overpressure disconnector, elastic elements must not
behindered and a minimum space of 12 mm has to be kept above each capacitor. Check tightness of the connections/terminals
periodically. The energy stored in capacitors may be lethal. To prevent any chance of shock, discharge and short-circuit the
capacitor before handling. Failure to follow cautions may result, worst case, in premature failures, bursting and fire. Iskra Sistemi,
d. d. is not responsible for any kind of possible damages to persons or things due to improper installation and application of
capacitors for power electronics.

Safety

Attention: Electrical or mechanical misapplication of capacitors may be hazardous.Personal injury or property damage may result
from bursting of the capacitor or from expulsion of oil ormelted material due to mechanical disruption of the capacitor. Ensure
good, effective grounding for capacitor enclosures. Observe appropriate safety precautions during operation (self-recharging
phenomena and the high energy contained in capacitors). Handle capacitors carefully, because they may still be charged even
after disconnection. The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized.
Follow good engineering practice.

Thermal load

Attention: After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not exceeded at
extreme service conditions.

Mechanichal protection

Attention: The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided.

Storage and operating conditions

Attention: Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or
the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid
conductive path between phases and/or phases and ground. The maximum storage temperature is 85 C.

Overpressure disconnector

Attention: Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or
the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid
conductive path between phases and/or phases and ground. The maximum storage temperature is 85 C.

19

Power electronics capacitors


Published by Iskra Sistemi, d. d. Version 3.0, October 2013 Prepress Nimbus d.o.o.

SI-