Beruflich Dokumente
Kultur Dokumente
Disclaimer
This brochure has been produced for you with the greatest of care. Nevertheless it The details are provided as unbinding general information and cannot substitute
is not possible to rule out mistakes completely. In such cases we cannot assume any detailed, individual consultation. Reprints even only of excerpts only allowed with
liability. The contents correspond to the status on going to print. Deviations cannot the explicit approval of GEA Bock GmbH. GEA Bock GmbH 2012
be ruled out because of the ongoing developement process for our products.
Vehicle compressors FK
Bock vehicle compressors of the FK range are the result of many years of experience in the
domain of mobile cooling systems.
The unsurpassed light, compact, robust design and wide r.p.m. range are only some of the
outstanding features of this unique product range of two, four and six cylinder compres-
sors.
A wide variety of designs can be tailored to suit individual requirements.
The so-called K version is a special innovation with a unique valve plate system for
maximum requirements in bus and coach air-conditioning systems.
Single-stage compressors
NH3 compressors
Compressor units for direct drive
NH3 Compressor units for direct drive
HG34P / 380 - 4 S HC
Hydrocarbons
Motor variant 3)
Number of poles
Swept volume
Pluscom 2) 1) HG = Hermetic Gas-cooled (suction gas-cooled)
Number of cylinders 2) = Additional declaration for Pluscom compressors
Size 3) S = More powerful motor e.g. air-conditioning applications
Series 1)
Overview hydrocarbons
Refrigerant Composition Name ODP GWP (100a) 2 3 Safety group Critical value
(Formula) [R11=1,0] [CO2=1,0] 1 [kg/m3]
2
R290 C3H8 Propane 0 3 A3 0,008
R1270 C3H6 Propylene 0 3 A3 0,008
R600a C4H10 Isobutane 0 3 A3 0,011
Special features
Based on our current semi-hermetic product range GEA Bock offers now a low-cost compressor variant especially for the use with
hydrocarbons.
Compressors in HC-design have the following features:
- Heat protection thermostat as standard - Oil sump heater as standard
- Special oil charge - Motor protection MP10 for installation in the switch cabinet
Important notes
We would like to explicitly state that those compressors are a special edition and the compressors filled with hydrocarbons are to be
operated by trained specialists only.
Please see assembly instructions for additional important instructions.
To ensure the safety measures, an additional agreement, hydrocarbons as refrigerant (GEA Bock-Art. No. 09996) has to be signed.
Additionally, ATEX compressors are available that can be operated with hydrocarbons as well.
You can find more information on these compressors in our ATEX brochure.
HC operating limits
40 50
40
30 tOh<20K
tOh+20C 30
tOh+20C
20 20
-40 -30 -20 -10 0 10 20 to (C) -30 -20 -10 0 10 20 30 to (C)
-35 -5 12,5 -25 12,5 25
Notes
Operating limits Performance data
Compressor operation is possible within the limits shown on the The performance data for the hydrocarbons R290, R600a and R1270
application diagrams. Please note the coloured areas. are based on 20 K suction gas superheat without liquid subcooling,
Compressor application limits should not be chosen for design at 50 Hz power supply frequency.
purposes or continuous operation. These are computed, preliminary values. Variations cannot be
excluded.
* PW = Part Winding, motors for part winding start 1 = 1. part winding 2 = 2. part winding
Explanations
1 Tolerance ( 10%) relates to the mean value of the voltage Oil sump heater 110-240 V - 1 - 50/60 Hz
range. Other voltages and current types on request. HG12P..HC, HG22P..HC, HG34P..HC: 50-120 W
PTC heater, self-regulating, installation in housing bore
2 - T he specifications for max. power consumption apply for
50Hz operation. For 60Hz operation, the specifications have Oil sump heater 230 V - 1 - 50/60 Hz
to be multiplied by the factor 1.2. HG4..HC: 80 W
The max. working current remains unchanged. HG5...HC, HG6...HC, HG7...HC: 140 W
- T ake account of the max. operating current / max. power HG8..HC: 200 W
consumption when designing contactors, leads and fuses. Permanently set version, installation in immersion sleeve
Switches: service category AC3
3 220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
4 380-420 V Y/YY - 3 - 50 Hz PW
440-480 V Y/YY - 3 - 60 Hz PW
PW = Part Winding, motors for part winding start
(no start unloaders required)
- Winding ratio: HG4, HG5, HG6 = 66% / 33%
- Designs for Y/ on request
5 380-420 V / YYY - 3 - 50 Hz PW
440-480 V / YYY - 3 - 60 Hz PW
PW = Part Winding, motors for part winding start
(no start unloaders required)
- Winding ratio: HG7, HG8 = 60% / 40%
- Designs for Y/ on request
ca.220
76
L1 B1 DV
A
B
ca.280
E H,D1
SV 1)
244
ca.115
A1 K,O
98
F
J1 4x 10
ca.135 162
66 208 192
318
ca.415
88
DV B1
L1
A
B
ca.310
SV 1) B
H,D1
264
A1
ca.135
E K,O
115
F J1
ca.115 4x 12
198
109 223
ca.240
328
ca.470
1)
SV 90 rotatable Dimensions in mm
Centre of gravity
ca.285
L1 DV B1
A
H,D1 B
ca.315
273 (271)
A1
SV 1)
E K,O
ca.135
A1
115
F J1
ca.170 4x 12
46 (43) 310 230
79 (74) 420 272
ca.515 (510)
ca.365
306
B B1
DV L A L1
C
E
SV 1) D H
ca.405
P D1
A1 O X
278
ca.180
F K
170
J1
Q 4x 11
V
25
ca.245
280
73 436
330
112 550 (535)
ca.725 (690)
1)
SV 90 rotatable Dimensions in mm
Centre of gravity - Dimensions for view X see page 24
ca.435
306
DV B A N B B1
C
L1 E
H
SV 1)
ca.405
D D1
O
283
A1 P
ca.180
170
F X
J1
Q ca.275 4x 11 V
25
83 508 290
122 ca.645 (630) 340
ca.830 (815)
ca.455
306
DV B A N B B1 L1
C
E
H
D1
ca.405
SV 1) P O
283
A1 D X
ca.185
F K
170
J1
Q ca.285 4x 11
V
25
290
83 533
340
122 669
ca.850
1)
SV 90 rotatable Dimensions in mm
Centre of gravity - Dimensions for view X see page 24
ca.510
DV B N A SV 1) A2 B1 A1 B
L1
C
P E
ca.500
H
439
D
331
D1
ca.215
F X
189
J1 K,O
Q ca.315 4x 11 V
90 472 290
150 612 340
ca.830
ca.580
DV B N A SV 1) A2 B B1 A1
L1
C
E
P
ca.655
H
D
570
K,O
412
D1
ca.285
X
252
F Q
J1
V1
ca.350 4x 13,5
100 569 360
163 680 430
ca.940
1)
SV 90 rotatable Dimensions in mm
Centre of gravity - Dimensions for view X see page 24
View X
12
4
12
4
Three-hole connection for oil level regulator
make ESK, AC+R, CARLY (3x M6, 10 deep)
47,6
Dimensions in mm
Attention:
Electric, respectively electronic components of the standard extent of delivery, from the accessories or that are obtained otherwise have to be
handled and mounted in such a way that the corresponding regulations for the use of hydrocarbons are fulfilled.
Attention:
Electric, respectively electronic components of the standard extent of delivery, from the accessories or that are obtained otherwise have to be
handled and mounted in such a way that the corresponding regulations for the use of hydrocarbons are fulfilled.
Start unloader / Capacity regulator ESS Electronic Soft Start EFCe Electronic Frequency Control external
1 3 2 4
ESP Electronic Single Phase Preparation for capacity regulator Oil pressure differential sensor
5 6 7
Oil service valve Water-cooled cylinder covers Connection piece in welded construction
8 9 10
11
Products
-- Comprehensive product brochure
-- Data on all products
-- Dimensions and exploded views
-- Spare parts lists
Sales network
-- Contact persons in over 60 countries
-- Direct link to your trading partner
Company
-- Current company information
-- Company film
-- Subsidiaries
-- History
-- References
News
-- Company news
-- Product news
-- Current dates
Know-how
-- Error analysis tool
-- VAP software
-- Comprehensive information
GEA Group is a global mechanical engineering company with multi-billion euro sales and operations
in more than 50 countries. Founded in 1881, the company is one of the largest providers of
innovative equipment and process technology. GEA Group is listed in the STOXX Europe 600 Index.
GEA Group AG. All rights reserved. 96153-02.2012-Gb Subject to change without notice Copyright GEA Bock