Planmeca Compact i Touch

Quick reference card

Patient chair control


Touch panel

Take into use the required dentist settings

Chair to autoposition A Short activation

Backrest down Long activation

Chair to autoposition B Short activation

Backrest up Long activation

Chair to autoposition C Short activation

Chair up Long activation

Chair to autoposition D Short activation

Chair down Long activation

Chair to spit position Short activation when LED OFF

Chair to previous position Short activation when LED ON

Chair to spit position only Long activation

Foot control

Short activation Chair to autoposition C

Long activation C Chair up

Short activation Short activation


Chair to autoposition A Chair to autoposition B
A B
Long activation Long activation Chair to
Backrest down Backrest up spit position

Short activation D Chair to autoposition D


Chair to
Long activation Chair down spit position
Dental unit control
Touch panel

Select language
Change language for dental unit
from list

Cup fill and bowl rinse Short activation

Cup fill as long as pressed (manual) Long activation

Bowl rinse Short activation

Preprogrammed door open / assistant call function Short activation

Door open / assistant call function as long as pressed (manual) Long activation

Operating light On Off Short activation

Intensity of operating light Long activation

Start required timer Select timer number

Maintenance procedure Select procedure

Foot control
No instrument activated
Preprogrammed
unit function

Preprogrammed
unit function

Assistant call

Short activation Cup fill and bowl rinse

Long activation Cup fill as long as pressed (manual)

Planmeca Compact i Touch


Instrument control
Touch panel
Micromotor Scaler
Instrument speed / power
Reverse rotation Operation / working
reduction On Off
On Off mode

Water & air Air No spray Turbine


Polisher
Scaler Quickstart
8-second cleaning cycle
Spray 1 Spray 2 On Off

Automatic chip blow Fibre optic light Polisher


On Off On Off 80-second cleaningcycle

Foot control
Micromotor or turbine (instrument activated) Scaler (instrument activated)

Drive instrument
Drive scaler

Drive instrument
Drive scaler

Short activation Water & air Air No spray Short activation Spray 1 Spray 2
Long activation Manual chip blow

Polisher (instrument activated) Polymerisation light (unit controlled instrument activated)

Drive polisher
Start Stop

Drive polisher
Start Stop

Long activation Momentary cleaning water No function

Intraoral camera (instrument activated)

Freeze Unfreeze
Preprogrammed
instrument
Freeze Unfreeze function

Short activation Save still picture

Touch panel, Bien-Air MX2 micromotor

Select preset for


Select required preset from list
MX2micromotor

When torque is enabled: toggle between

RPM limit On Off

Torque limit On Off


Normal Auto reverse Auto forward

Quick reference card


Motorised headrest control
Foot control

Short activation Normal mode On Off

Long activation Tilt mode On Off

Normal mode Lengthen headrest

Tilt mode C Move headrest up

Normal mode Normal mode


Anatomical movement down Anatomical movement up
A B
Tilt mode Tilt mode
Tilt headrest backward Tilt headrest forward

Normal mode D Shorten headrest

Tilt mode Move headrest down

Programming
Patient chair autoposition settings

Select dentist Move chair to Start Press desired button where Switch operating Accept new
number required position programming tostore chairposition light On Off autoposition

Unit settings
Most programming follows this simple sequence:

Start programming Select function Adjust value Accept new value

Instrument settings
Most programming follows this simple sequence:
10029686_3/04.2012/en

Activate instrument Start programming Select function Adjust value Accept new value

For detailed instructions, please see the users manual. Copyright Planmeca. Rights for changes reserved.