Building Integrated Photo Voltaic Systems ( BIPV)
Wind Array Turbine System (WATS)

By
First Green Consulting Pvt Ltd, Gurgaon
First Green Consulting Pvt Ltd. , U 28, A / 3, First Floor, DLF Phase III, Gurgaon 122002 1
Building Integrated Photo Voltaic Systems ( BIPV)
What is BIPV ?
BIPV or Building Integrated Photo Voltaic, as the
name suggests deals with integrating the Solar Photo
Voltaic panels into building design. The can be used
to replace proposed glazing areas without affecting
the contemporary aesthetics of steel & glass or fixed
on South faade as building cladding.
BIPV benefits:
The building itself becomes the PV support structure
BIPV components displace conventional building materials and labour, reducing
the net installed cost of the PV system
On-site generation of electricity offsets imported and often more carbon-
intensive energy
Architecturally elegant, well-integrated systems will increase market acceptance
BIPV systems provide the building owners with a highly visible public expression
of their environmental commitment

First Green Consulting Pvt Ltd. , U 28, A / 3, First Floor, DLF Phase III, Gurgaon 122002 2
BUILDING INTEGRATION APPLICATION TYPES:
Roof Integration

Skylights Canopies/Pergolas

Building Envelope/Faade

First Green Consulting Pvt Ltd. , U 28, A / 3, First Floor, DLF Phase III, Gurgaon 122002 3
Design Considerations
Areas Available Roof, Pergolas/canopies , Faade or Spandrel area
installation.
Type of PV Module- Mono-Poly Crystalline , Thin Film.
Orientation of Elevations
Anticipated Energy Production

Technology Considerations
Transparent PV Modules.
Flexible Panels
Fixed Non Transparent Panels

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 4
BIPV Applications

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 5
Preliminary Analysis For BIPV for a Sample Case Study

Area required = 10m2/kw


Possible BIPV areas available include.

1. South faade Wall Area= 1000 sqm ( 100 KW


system)
2. Spandrel wall areas = 500 sqm ( 50 Kw system)
3. Pergola at Roof = 75 Sqm ( 8 Kw System)
4. Entrance Canopy= 75 Sqm ( 8 Kw System)

Pergola at roof
Faade wall area for BIPV

Spandrel area for BIPV


Entrance area Canopy on
ground floor

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 6
Use of Transparent PV Panels in Building Faade.

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 7
Use of Transparent PV Panels in Railings, Faade & Fence

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 8
Use of BIPV Panels in Building Faade.

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 9
BP Solar Photovoltaic Modules
Integrated into a BP Service Station
Canopy

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 10
Photovoltaic Modules with Vision
Light Integrated into a Skylight

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 11
Building Integrated PV Technology
with Canopies/Pergolas

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 12
Building Integrated PV
Technology with Faade
Walls

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 13
Building Integrated PV Technology
Spandrel Areas

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 14
Wind Array Turbine System (WATS)
What is WATS ?
The Wind Array Turbine System (WATS) is the unique system where Wind
Turbines are designed to be installed in an array. The system provides the
architectural flexibility to capture the energy of the wind in urban and suburban
environments.

These turbines are small and light-weight in design, and therefore it facilitates
easy integration into a variety of architectural landscapes, adding both power
production and aesthetics to any project.

First Green Consulting Pvt Ltd. , U 28, A / 3, First Floor, DLF Phase III, Gurgaon 122002 15
WATS - Applications
The turbines can be installed on rooftops, parapets, side walls, and pole
structures. Custom applications can also be implemented.
Performance
Rated Power: 240 Watts at 35 MPH
Generator: 3-phase, rated at 500 Watts
Output Voltage Rating: 30V constant-voltage
Output Current Rating: up to 8 Amps
Different Blade Configurations

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 16
Turbine Mounting Systems
Several different types of mounting systems are available to give the
flexibility to easily attach to various types of building surfaces.
Turbines can be positioned as close as 4 -6 apart or even closer, 2-3
apart, with alternate mounting layout.

Parapet Mount Staggered Wall Mount Roof Mount


Parapet
Mount

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 17
Wind Energy Building Platforms

The windy side of a building


can produce an updraft,
AirFlow at Building Roof Edge
which if harnessed properly,
can produce thousands of KW
Hours of power per year.

Enough to power the building


and perhaps the entire block
through mini-grids. Unlike
solar energy systems wind
energy can work all day and
all night.

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 18
Building Integrated Wind Turbine System- Project Photographs

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 19
Building Integrated Wind Turbine System-
System Project Photographs

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 20
Building Integrated Wind Turbine System
( Parapet at Roof)

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 21
Building Integrated Wind Turbine System- Project Photographs

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 22
Building Integrated Wind Turbine System
Architectural Applications

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 23
Sample Cost Analysis (BIPV)
Sample Costing for 100 KW system

Cost per sqft Rs 100 per watt


Cost of 100 KW System Rs 10,000,000

Say Rs 1 Crore (Approx)

Area Required for 100 KW system 1000 Sqmt

Approx. Structural Glazing cost Rs 6,000 per sqmt


Total Structural Glazing Cost in 1000 Sqmt area Rs 6,000,000
Say Rs 60 Lakhs (Approx)

Incremental Cost for BIPV Installation Rs 4,000,000

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 24
Sample Cost Analysis (BIPV)
( 1 Crore*0.80*0.33)
Depreciation Benefit in 1st year Rs 2,640,000
Say Rs 2,500,000

Electricity Generated by 1 KW system in 1 year 1200 Kwh


Electricity Generated by 100 KW system in 1 year 120000 Kwh
Cost of electricity saved( @Rs7/Kwh) in 1st year Rs 840,000
Say Rs 800,000

Effective Incremental cost for BIPV in 1st year Rs 700,000

Pay Back Period 2 Years


Pay Back Period ( Without Depreciation Benefit) 5 Years

Firstgreen Consulting Pvt Ltd. B 1202 Millenium Plaza, Sec 27 Gurgaon 122002 25
Thank You Contact Us:
First Green Consulting Private Limited
Gurgaon:
First Floor, U 28, A / 3, DLF Phase III, Gurgaon
122002, India
Tel.: (+91) 124 406 3031
Mobile: +91 9899295854

Web: www.firstgreenconsulting.in
Email: sanjayv@firstgreenconsulting.in
Blog: http://firstgreenconsulting.wordpress.com

First Green Consulting Pvt Ltd. , U 28, A / 3, First Floor, DLF Phase III, Gurgaon 122002 26

Das könnte Ihnen auch gefallen