Sie sind auf Seite 1von 5

OWNER : TIGER RESORT, LEISURE AND ENTERTAINMENT, INC.

PROJECT : MANILA BAY RESORT


LOCATION : OKADA RESORTS, BAGONG NAYONG PILIPINO ENTERTAINMENT CITY,
BARANGAYS TAMBO AND DONGALO, PARAAQUE CITY
GROUP A : HILMARCS CONSTRUCTION CORPORATION
GROUP B : DDT KONSTRACT, INC.
SUBJECT : SPECIFICATIONS - (PASSENGER ELEVATORS: ESTS 1) PE-11 & PE-12
FILE NO . : MP995

EQUIPMENT SCHEDULE
&
TECHNICAL SUMMARY
ESTS 1
PE-11 & PE-12
Passenger Elevators

REG NO. : 2886 TIN : 112-191-886


Oscar V. Relucio
PTR NO. : 3673893 DATE : 03 January 2013
Professional Mechanical Engineer
PLACE : Makati City
OWNER : TIGER RESORT, LEISURE AND ENTERTAINMENT, INC.
PROJECT : MANILA BAY RESORT
LOCATION : OKADA RESORTS, BAGONG NAYONG PILIPINO ENTERTAINMENT CITY,
BARANGAYS TAMBO AND DONGALO, PARAAQUE CITY
GROUP A : HILMARCS CONSTRUCTION CORPORATION
GROUP B : DDT KONSTRACT, INC.
SUBJECT : SPECIFICATIONS - (PASSENGER ELEVATORS: ESTS 1) PE-11 & PE-12
FILE NO . : MP995

SUPPLY AND INSTALLATION OF ELEVATORS

Equipment Schedule and Technical Summary

Consultant's Requirements Supplier's Offer

Elevator Designation PE-11 & PE-12


Product Specifics
Model Offered Supplier to Specify
Point of Origin Supplier to Specify

General
Requirements
Speed 1.0 m/s
Capacity 1275 Kg
Additional Load
Requirements for Internal 452.22 kgs
Finishes
No. of Stops 2
Total Travel Distance 6500 mm
Internal Car Area
Requirement 2000 mm x 1400 mm
Internal Car Height
Requirement (Finish) 2700 mm
Elevator Arrangement 2 in a Bank
Available Hoistway 5650 mm x 2000 mm
Dimension (Width x Depth)
Available Pit Depth 1600 mm
Available Overhead 7200
Traction Motor and Controls
Traction motor model Supplier to specify
Permanent Magnet-
Type Gearless
VVVF with regenerative
Drive drive
Electrical supply (voltage) 400 Volts
Power Requirement
(KVA/motor) Supplier to specify
Demand- based
Dispatching System dispatching to minimize
waiting time
Back up Battery Power
Supply for Emergency Required
Landing to Nearest Floor

REG NO. : 2886 TIN : 112-191-886


Oscar V. Relucio
PTR NO. : 3673893 DATE : 03 January 2013
Professional Mechanical Engineer
PLACE : Makati City

Page 1 of 4
OWNER : TIGER RESORT, LEISURE AND ENTERTAINMENT, INC.
PROJECT : MANILA BAY RESORT
LOCATION : OKADA RESORTS, BAGONG NAYONG PILIPINO ENTERTAINMENT CITY,
BARANGAYS TAMBO AND DONGALO, PARAAQUE CITY
GROUP A : HILMARCS CONSTRUCTION CORPORATION
GROUP B : DDT KONSTRACT, INC.
SUBJECT : SPECIFICATIONS - (PASSENGER ELEVATORS: ESTS 1) PE-11 & PE-12
FILE NO . : MP995

Noise Level When Running <70 dbA


Type of brakes/Point of Origin Supplier to specify
Brake release mechanism Supplier to specify
Max brake torque (N-m) Supplier to specify
Leveling Accuracy +- 5 mm
Regenerative Converter Required
Door Requirement
Width X Height 1200 mm x 2400 mm
Type of Construction 1.5 hours fire rated
Infrared beam to cover full
Door Safety door height with leading
door edge
Type of Opening Center Opening
Opening time (sec) Should be adjustable
Closing time (sec) Should be adjustable
Required on every landing
Door Key Holes doors
Door Transom On main lobby only
As per architectural
Finish requirement
Door Motor Control VVVF
Lobby Requirements
Landing Gong Required on every landing
Directional Arrow Required on every landing
Car Position Indicator On Main Lobby only
Sound Level Requirements 75 dBA

Inside the car


Micro-movement and
COP Buttons vandal resistant
Emergency Lights Required at least 2 hours
Three way intercom
(Uppermost lift lobby,
Intercom security room &car) with 2
hours emergency
operation capability
Alarm buttons Required
Handrails Required

Ventilation Fan with back up Required


Power Supply (2 hours)
Emergency Door Required

REG NO. : 2886 TIN : 112-191-886


Oscar V. Relucio
PTR NO. : 3673893 DATE : 03 January 2013
Professional Mechanical Engineer
PLACE : Makati City

Page 2 of 4
OWNER : TIGER RESORT, LEISURE AND ENTERTAINMENT, INC.
PROJECT : MANILA BAY RESORT
LOCATION : OKADA RESORTS, BAGONG NAYONG PILIPINO ENTERTAINMENT CITY,
BARANGAYS TAMBO AND DONGALO, PARAAQUE CITY
GROUP A : HILMARCS CONSTRUCTION CORPORATION
GROUP B : DDT KONSTRACT, INC.
SUBJECT : SPECIFICATIONS - (PASSENGER ELEVATORS: ESTS 1) PE-11 & PE-12
FILE NO . : MP995

Equipment Inside The Hoistway


Car Guide Rails T-127 (solid steel)
Counterweight Guide Rails T-89 (solid steel)
Spacing of Bracket every 2.0 meters
Size of Hoisting Rope at least 12 mm diameter
Safety Factor for Hoisting Rope at least 12
Compensating Rope Quiet operating chains
Buffer Oil Type - Dissipated
Buffer Point of Origin Supplier to specify
Instantaneous Type
Safety gears
Governor Actuated
Electrical Raceways inside the
hoistway Should be metal
Others
Counterweight Safety Gear Required
Anti nuisance Required
- Smooth Landing Required
- Alternate Landing Required
- Automatic bypass Required
- Overload holding stop Required
- Car light/fan shut-off-automatic Required
Service Feature
- Car call erase Required
- Attendant service Required
- Independent service Required
Features for comfort and convenience
- Door sensor self-diagnosis Required
- Automatic door speed control Required
- Automatic door-open time
adjustment Required
- Re-open with hall button Required
- Repeated door-close Required
- Extended door-open button Required
- Door nudging feature Required
- Door load detector Required
- Safety door edge Required
Signal & display feature
- Car arrival chime Required
- Interphone (3-way) Required

REG NO. : 2886 TIN : 112-191-886


Oscar V. Relucio
PTR NO. : 3673893 DATE : 03 January 2013
Professional Mechanical Engineer
PLACE : Makati City

Page 3 of 4
OWNER : TIGER RESORT, LEISURE AND ENTERTAINMENT, INC.
PROJECT : MANILA BAY RESORT
LOCATION : OKADA RESORTS, BAGONG NAYONG PILIPINO ENTERTAINMENT CITY,
BARANGAYS TAMBO AND DONGALO, PARAAQUE CITY
GROUP A : HILMARCS CONSTRUCTION CORPORATION
GROUP B : DDT KONSTRACT, INC.
SUBJECT : SPECIFICATIONS - (PASSENGER ELEVATORS: ESTS 1) PE-11 & PE-12
FILE NO . : MP995

Emergency operations & features


- Auto-operation by
emergency power source Required
- Fireman's emergency
operation Required - Phase 1
- Elevator monitoring and
control system Required
- Emergency car lighting and
ventilation fan (2 hrs back-up) Required
- Auto emergency landing
device Required
- Earthquake device Required
Security Features
- Provision for future CCTV
and Card Reader in
Travelling Cable Required

REG NO. : 2886 TIN : 112-191-886


Oscar V. Relucio
PTR NO. : 3673893 DATE : 03 January 2013
Professional Mechanical Engineer
PLACE : Makati City

Page 4 of 4

Das könnte Ihnen auch gefallen