2.

Turbine make/design
3. Rated Capacity (MW) 500 MW
4. VWO Capacity (MW) 537
5. Rated Condenser Vacuum (MM of Hg abs) 77
6. Rated CW Inlet Temp.0C 320C#1, 360C#2
7. Number of turbine cylinders 3 HP/IP/LP
8. Barring gear a) Type b) Speed (RPM) c) Location Motorised 11 On brg. No.
2 9. Critical Speeds (RPM) a) HP Rotor b) IP Rotor c) LP Rotor d) Combined I II III - - 2450 - -
2100 1300 4250 - 700 2150
10. Operation Frequency Regime a) Continuous Operation b) Limited Operation range
continuous at a stretch & total life time 47.5 - 53 Hz 53.0 Hz width no time delay
11. Droop/Regulation a) Standard droop % b) Droop ineffective range 6% 47.5-52.5 Hz
12. Governing
a) Type
b) Operation modes
c) Overspped tripping Speed
d) Dead band
e) Speed sensing device Nozzle Combined EHC i)+10% ii) 12% (mech. overspeed) 47.5-52.5 Hz
Inductive (works on principle of eddy current)
13. Turbine type Impulse HP/IP/LP
14. HP a) Type b) No. of casings c) No. of flows d) Blade carrier/blade type e) Inlet parameter
i) Pressure (KG/cm2)
ii) Temperature 0C
iii) Wheel chamber pressure
f) Exhaust Parameter i) Pressure (KG/cm2) iv) Temperature 0C Split 2 Single - 170 537 140.4
(during PG test ) 46 343
15. IP Casing a) Type b) No. of casings c) No. of flows d) Blade carrier/blade type e) Inlet
parameter i) Pressure (Kg/cm2) ii) Temperature 0C f) Exhaust Parameter i) Pressure (Kg/cm2) ii)
Temperature 0C Split 2 Double - 40.57 537 6.47 276.8

16. LP Casing a) Type b) No. of casings c) No. of flows d) Blade carrier/blade type e) Inlet
parameter i) Pressure (Kg/cm2) ii) Temperature 0C f) Exhaust Parameter i) Pressure (Kg/cm2) ii)
Temperature 0C Split 2 Double - 6.147 276.8 0.121 49.3
17. Bearing Pedestals Type a) HP front b) Between HP/IP c) Between IP/LP d) LP-1&LP-2 (if
applicable) e) Between LP & Generator Fixed Sliding Fixed Not applicable Fixed
18. Bearing Type/Size
I. HP front
II. Between HP & IP
III. Between IP & LP
IV. Between LP & Gen
. V. Between Gen. & Exciter
VI. Exciter Rear (mm x mm dia)
157 x 200 260 x 315 371 x 525 421 x 475 371 x 425 (Bet gen & Exc.) 211 x 250 (Exc rear)

19. Bearing Seating Type a) Bearing no. 1 b) Bearing no. 2 c) Bearing no. 3 d) Bearing no. 4 NA
20. Turbine rotors a) HP rotor i) Type ii) Weight iii) Length (coupling to coupling) b) IP rotor i)
Type ii) Weight iii) Length (coupling to coupling) c) LP rotor i) Type ii) Weight iii)Length (coupling
to coupling) Disc. Type 10.60 tonnes 5500 mm Disc. type 20.00 tonne 4667mm Disc 53.7 tonnes
6462

21. HP stage blading a) No. of blades /Stage No. b) Shroud type/section c) Root type/section NA
All integral All dove Tail
22. IP stage blading a) No. of blades / stage b) Shroud type/section c) Root type/section NA All
Integral shroud All dove. Tail

23. LP stage blading a) No. of blades / stage b) Shroud type/section c) Root type/section NA All
integral except last 2 stages which are Free standing. All dove tail except last 2 stages which are
FIR TREE type.

24. Stop & Control Valves


a) Type Combined/Separate
b) Location : Mounted on turbine away from turbine
c) Number of valves i) HP ii) IP
d) Actuating servomotor Common/dedicated to each valve i) HP ii) IP
e) Pilot/Relief valves-Yes/No (Integral)
f) Valve Travel (m.m)
g) Facility for individual valve testing manual automatic/not available In HPT-Separate, In IPT-
Combined Mounted on Turbine
i) 2 nos S/V & 4 nos. S/V
ii) 2 nos. combine SV & CV Dedicated to each valve Yes HPCV - 49.0 mm HPSV - 83.3 mm
IPCV 172.0 mm IPSV 153.7 mm Auto
25. Couplings i) HP/IP ii) IP/LP iii) LP/Gen iv) HP/MOP Type Rigid Rigid Rigid Rigid

26. Turbovisory
a) Total expn. At HP front
b) Expansion at IP pedestal
c) Differential expn limits HP IP LP
d) Axial shift trip valve (Limit) 27.90 mm 11.70 mm + 8.31 mm to 0.52 mm + 13.95 mm to
1.48 mm + 16.00 mm to 4.0 mm + 0.8 mm

27. Automatic Turbine Run up System (ATRS) Incorporated / not incorporated


Incorporated
28. Automatic testing of protection devices (ATT)
a) Incorporated / not incorporated
b) If incorporated testing envisaged Overspeed at operating speed Axial shift/high thrust
wear Stop valves Vacuum protection Any other protection Incorporated
Yes Yes Yes Yes Lube oil pr. & MOT Level low protection

29. Design heat rate (Kcal/Kwhr)


At 100% load
At 80% load
At 60% load Heat Rate
At rated conditions Make up % Conds. Vac. 1988.1 0% 77 mmHg 2006.4 0% 77 mmHg 2047.1
0% 77 mmHg

30. Extraction : Location


Turbine & Stage No.
a) H.P. Turbine Stage
b) H.P. Exhaust
c) I.P. Turbine (5th stage towards HPT)
d) I.P. Turbine Stage (13th stage towards LPT)
e) L.P. Turbine (Ist stage) x 2
f) L.P. Turbine (3rd stage) x 2
g) L.P. Turbine (4th stage) x 2
Extr. Heater Pr. Temp. Flow No. TerminalKg/CM2 C T/hr - - - - - 6 HPH-6A 44.67 342.6 108.6 &
6B 5 HPH-5A
25.83 470.6 109.26
& 5B 4 Dear. + 9.826 337.7 160.6
TDBFP 89.76 +70.85) 3 LPH-3 3.596 221.4 8.802 2 LPH-2 1.366 120.2 56.696 1 LPH-1 0.573
81.5 62.534
31. Extractions NRV No. of NRV s type 1 No valve Make 2 1 swing CHK V/V (Pneumatic) 1
swing CHK V/V (Mech.) 3 1 swing CHK V/V (Pneumatic) 1 swing CHK V/V (Mech.) - 4 4 swing
CHK V/V (Pneumatic) - 5 2 swing CHK V/V (Pneumatic) - 6 2 swing CHK V/V (Pneumatic) - CRH
Line 2 swing CHK V/V (Pneumatic)
32. HP Bypass Type Size Make Capacity (Rated % flow) Jacking Cooling Provided Downstream
Parameter
i) Pr
ii) Temperature
ARS-100 Actuator ASM 160 11 Flow area 42.44 CM2, seat dia 100 mm
Sulzer 270.4 tonnes/hr per valve No 33 Kg/cm2 3100C
33.
33.1 Oil System Main Oil Tank (Lube Oil) i) Tank Capacity (m3) ii) Oil requirement for NWL (m3)
iii) Type of strainer iii) Size of strainer 40 40 Basket
32.2 Oil vapour exhauster i) No. & Location 2 nos. on MOT
33.3 Centrifuge i) Type & make ii) Capacity (Ltrs/hr) WHPX 40 g/Alpha Laval 8000 ltr/hr
33.4 Oil Cooler i) Nos. & standby ii) Type of Tubes arrangement iii) Material of tubes 2 (1
standby) U- Tubes Admirality Brass
33.5 Main oil pump i) Speed ii) Coupling arrangement iii) Discharge Pr. iv) Flow / capacity v) No.
& type of bearing 1410 rpm Gear coupling 4.0 Kg/cm2 2200 ltr/minute
33.6 Auxiliary Oil Pump i ) Numbers ii) Make iii) Speed iv) Discharge Pressure v) Rated flow vi)
Mounting location vii) Type of mounting (V/H) viii) Motor make & rating
Two (AC Driven) Allweiler (NSS-8-200) 3000 rpm 4.0 Kg/cm2 1980 lit/min Top of main oil tank
Vertical 24.2 KW

33.7 Emergency oil pump (DC) a) Make b) Speed (RPM) c) Discharge PR (ata) d) Rated flow
(dm3/Sec) e) Mounting location f) Mounting arrangement (V/H) g) Motor, make, rating Allweiler
1500 1.3 kg/cm2 1020 lit/min On Top of MOT Vertical 3.8 KW

33.8 Jacking Oil Pump a) No. of pumps AC/DC b) Type of pump/make c) Discharge pressure d)
Speed rpm e) Capacity f) Motor make, rating, frame size 2 a.c and 1 d.c. each for bearing 3, 4 &
5 Q34-010R BDZ Maximum pr. 250 kg/cm2 1450 rpm 1.5 lit/min. 8.7 KW

34. Fire Resistant Fluid System Yes


34.1 Type & make of fluid (Unit wise if different) Fyrquel EHC/Shell HTGD 690, 149
34.2 Tank Details a) Tank capacity b) Fluid requirement for NWL c) No. of strainer d) Strainer
size e) Heater nos. f) Type of heaters 6000 litres First filling 6900 lits Two Nil Nil

34.5 FRF Pumps a) Numbers b) Make & Type c) Rated flow d) Rated pressure e) Speed f) Motor
i) Make ii) Rating iii) Frame size

Two Aliweiler SNDAT 1300-42 876 lit/min 40 Kg/cm2 1500 rpm - 81KW - 34.6 FRF Regenerative
System a) Type of system b) Details of filter Earth filter Fine mesh filter c) Type d) Filter size
Fuller s earth Rotring, Attha pulgus clay - - Rotring fine filter