Piston Flow Meters monitoring

for Viscous Media


analysing

DRZ

Measuring range: 6 - 420 l/h liquid


Measuring accuracy: 1,0% of reading
pmax: 40 bar; tmax: 80 C
Viscosity range: 5 - 100 mm2/s
Connection:
G, G , " NPT, " NPT
Material: brass housing
Model: DRZ-...C3

Model: DRZ-...0000
with AUF

Model: DRZ-...F
DRZ-...L

KOBOLD companies worldwide: KOBOLD Messring GmbH


Nordring 22-24
ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLUMBIA, CZECHIA, D-65719 Hofheim/Ts.
DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDO- Head Office:
NESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, +49(0)6192 299-0
+49(0)6192 23398
SOUTH KOREA, SPAIN, SWITZER-LAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM info.de@kobold.com
1/05- 2013

www.kobold.com

1
Piston Flow Meters Model DRZ

Description Technical Details


KOBOLD piston ow meters are direct volume counters, also Measuring range: 6-420 l/h
called displacement counter (positive displacement meter). Max. ow rate: 600 l/h
Its function is based on continuous limitation of a denite Measuring accuracy: 1.0% of reading
part-volume of the ow in a measuring cell through continu- Repeatability: 0.2%
ous lling and emptying of this measuring cell. The measuring
Standard viscosity range: 5-100 mm2/s
cell consists of the measuring chamber and the moving part,
the piston. Process temperature: max. 80 C
The piston is driven by the pressure difference between inlet Ambient temperature: -10 ... +60 C
and outlet of the measured media. The revolution is carried Max. pressure: 40 bar
forward via a magnet and a magnet eld sensor. Max. pressure loss: 1.5 bar
In cross section the u-formed piston is guided with its piston Connection: Female thread G , G ;
and guiding-adaptor in a ring chamber at the bottom and top " NPT, " NPT
of the measuring-body and also with its slot at the bafe. Mounting position: independent
The inlet and outlet openings are located on both sides of Recom. Filter neness: 100 m
the chambers wall. They are constantly sealed by the piston
Protection type: IP 65
and the bafe.
Weight: approx. 0.7 kg
The incoming measured media lls up the sickle shaped (DRZ-..F.., DRZ-..L..)
space, it wants to increase this space and therefore turns approx. 1.0 kg (DRZ-..C..)
the piston, until one after the other the volumes V1 and V2
are reached. While moving ahead, these lled spaces get Materials
connected with the outlet and are emptied. Since both sickle Housing: Brass
shaped spaces - the inner and the outer - are displaced to Piston: Aluminium
one another, the piston movement will not have a dead center. Magnet holder: POM
The piston moves continuously depending to the measured
Magnet: Permanent magnet
ow.
O-ring/Seal: FPM
Electronics
Position
Stellung 11 Position
Stellung 22 Position 3
Stellung 3 Position44
Stellung
OEM-frequency output (...0000), without CE
Housing
Gehuse V2 Axle
Achse V1
Adapter
Zapfen V2 V1
Power supply: 5-24 VDC
Piston
Ringkolben
end V1
Bafe
Trennwand
V2
Supply current: 10 mA
V1
V2 Pulse output: NPN, open collector,
Inlet
Flssigkeits- Flssigkeits-
Outlet max. 15 mA
eintritt austritt

Impulse rate: 405 pulses/liter


One complete turn of the piston adaptor end is equal to the Electr. connection: Plug connector DIN 43650
ow of the measuring chamber content (V1 + V2). With the Option: Plug-on display AUF-4000
help of a located magnet and a Hall-type sensor it is possible with 4-20 mA output/24 VDC
to create a digital signal, which can be evaluated.
Frequency output (...F300)
Power supply: 12-28 VDC
Supply current: 10 mA
Application examples
Pulse output: PNP, open collector,
Heating oil consumption measurement max. 25 mA
Fuel consumption measurement Impulse rate: 432 pulses/liter
Consumption control Electr. connection: Plug connector M12x1
Flow measurement of mineral-oil
Frequency output with frequency divider (...F3X0)
Dosing and bottling of oil
Power supply: 24 VDC 20%
Engine-testing application
Supply current: 15 mA
Pulse output: PNP, open collector,
max. 25 mA
Electr. connection: Plug connector M12x1
Division factor: 1...1/128, set by customers
request
1/05- 2013

2 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Piston Flow Meters Model DRZ

Technical Details (continued) Electrical connection


Analogue output (...L303; ...L343) DRZ-..F3..; DRZ-..L3..
Power supply: 24 VDC 20%
nc + Vs
Output: 4-20 mA, 0-20 mA, 3-wire 1
2
Max. load: 500 GND 4 Signal out
3
Electr. connection: Plug connector M12x1
Compact electronics (..C3..)
2 GND
Display: 3-segment LED DRZ-..0000
Analogue output: (0)4...20 mA adjustable,
max. 500 3 NPN, O.C.
Switching output: 1 (2) semiconductor PNP or
NPN, factory setting
Contact function: N/C / N/O programmable 1 + Vs
Setting: via 2 buttons
Power supply: 24 VDC 20%, DRZ-..C3..
3-wire technology,
out 2 + Vs
approx. 100 mA
Electr. connection: Plug connector M12x1 GND 2 1
3 5 4
GND Switch out 1

Order Details: (Example: DRZ-1110 G1 F300)


Version Model Connection Evaluating electronics
OEM-frequency output, no CE
0000 = DIN plug connector, NPN
Frequency output
F300 = plug connector M12x1, PNP
F320 = plug connector M12x1, PNP, divider 1:2
G1 = G female F340 = plug connector M12x1, PNP, divider 1:4
F390 = plug connector M12x1, PNP, divider 1...1/128
Brass housing G2 = G female
DRZ-1110 Analogue output
6-420 l/h oil N1 = " NPT
L303 = plug connector M12x1, 0-20 mA, 3-wire
N2 = " NPT L343 = plug connector M12x1, 4-20 mA, 3-wire
Compact electronics)
C30M = LED display, 2xNPN switch. output, plug connector M12x1
C30R = LED display, 2xPNP switch. output, plug connector M12x1
C34N = LED display, 4-20 mA, 1xNPN switch. output, plug connector M12x1
C34P = LED display, 4-20 mA, 1xPNP switch. output, plug connector M12x1
1)
Please specify ow direction in writing.
Plug-on display Pressure loss diagram
for model DRZ...0000 (OEM version, NPN- and DIN connector) 2,0 100 cSt
10 cSt

Bestellnummer Beschreibung 1,8 46 cSt

4-digit red LED, 1,6


Plug connector DIN 43650
1,4
Input: pulses of DRZ (NPN-Hall effect sensor)
[bar]

AUF-4000
[bar]

Output: 4-20 mA, 3-wire 1,2


loss P P

Load: max. 250


Druckverlust

Power supply: 24 VDC 1,0


Pressure

0,8

0,6

0,4

0,2

0
0 2 4 6 8 10 12
1/05 - 2013

Q [L/min]

No responsibility taken for errors; www.kobold.com 3


subject to change without prior notice.
Piston Flow Meters Model DRZ

Dimensions
Mechanical connection
31,1 33 xx5-10
5-10tief deep

Process connection

37,6

44

56
8

G
G
14

" NPT
" NPT

Inlet
Einlauf 20 Outlet
Auslauf

DRZ-...0000 with AUF DRZ-...0000


35

82
134,5

44,5
79,5

56
44,5

56
35
31,5

42

DRZ-..F3..; DRZ-..L3.. DRZ-...C3


44,5

M12x1
M12x1

106,5

12
82,8
98,5

47
44,5
44,5

56

56
1/05- 2013

4 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.