ANALISIS ESTRUCTURAL

I. PREDIMENSIONAMEINTO

I.1. LOSA ALIGERADA


Peralte:

PERALTE
CRITERIO
L :Luz critica (L = 5.00m)
S/C250Kg/m2 h=L/26 h=5/26 = 19cm
Calidad de construccin h=L/25 h=5/25 = 20cm
Norma E 0.20 (RNE) h=L/25 h=5/25 = 20cm

TIPIFICACION DE LOSA
2 AT 0.20
3 AT 0.20
4 AT 0.20
az AT 0.20

I.2. VIGA PRINCIPAL

BASE PERALTE
NIVEL S/C (losa) b=BT/20=(L1/2+L2/2)/20 h=L/11
BT: Ancho tributario L: Luz critica
Cuarto 100Kg/m2 b=( 5.0/2+5.0/2)/20=0.25m h=6.5/11=0.60m
Tercero 200Kg/m2 b=( 5.0/2+5.0/2)/20=0.25m h=6.5/11=0.60m
Segundo 200Kg/m2
Primero 250Kg/m2 b=( 5.0/2+5.0/2)/20=0.25m h=6.5/11=0.60m

TIPIFICACION DE VIGAS
PORTICO EJE 1 PORTICO EJE 2 PORTICO EJE 3 PORTICO EJE 4
4V1-AE-0.25*0.60 4V2-AE-0.25*0.60 4V3-AE-0.25*0.60 4V4-AE-0.25*0.60
3V1-AE-0.25*0.60 3V2-AE-0.25*0.60 3V3-AE-0.25*0.60 3V4-AE-0.25*0.60
2V1-AE-0.25*0.60 2V2-AE-0.25*0.60 2V3-AE-0.25*0.60 2V4-AE-0.25*0.60

I.3. VIGA SECUNDARIA

BASE PERALTE
NIVEL S/C (losa) b=BT/20=(L1/2+L2/2)/20 h=L/11
BT: Ancho tributario L: Luz critica
Cuarto 100Kg/m2 b=( 6.5/2+6.5/2)/20=0.35m h=5.0/11=0.45m
Tercero 200Kg/m2 b=( 6.5/2+6.5/2)/20=0.35m h=5.0/11=0.45m
Segundo 200Kg/m2
Primero 250Kg/m2 b=( 6.5/2+6.5/2)/20=0.35m h=5.0/11=0.45m

TIPIFICACION DE VIGAS
PORTICO EJE A PORTICO EJE B PORTICO EJE C PORTICO EJE D
4VA-AE-0.35*0.45 4VB-AE-0.35*0.45 4VC-AE-0.35*0.45 4VD-AE-0.35*0.45
3VA-AE-0.35*0.45 3VB-AE-0.35*0.45 3VC-AE-0.35*0.45 3VD-AE-0.35*0.45
2VA-AE-0.35*0.45 2VB-AE-0.35*0.45 2VC-AE-0.35*0.45 2VD-AE-0.35*0.45
ANALISIS ESTRUCTURAL

I.4. COLUMNAS

Usando la metodologa de Yamashiro.

Ac = k*At

Ac : rea de la seccin transversal de la columna


At : rea acumulada del piso considerado
k : Coeficiente

rea TIPO DE COLUMNA


PISO LUZ tributaria
C1 C2 C3 C4
por piso
4.00 16.00 0.0013 0.0025 0.0022 0.0040
Antepenltimo
6.00 36.00 0.0011 0.0020 0.0016 0.0028
piso
8.00 64.00 0.0011 0.0017 0.0015 0.0023
4.00 16.00 0.0011 0.0014 0.0014 0.0021
Segundo piso 6.00 36.00 0.0012 0.0014 0.0014 0.0015
8.00 64.00 0.0012 0.0014 0.0014 0.0015
Valores de los coeficientes k

Analizando el segundo piso:

COLUMNA At (m2) K Ac (cm2)


C1 6.25*4.75=29.21 0.0012(*) 0.0012*29.21*3*1002=1051.65
C2 3.125*4.75=14.61 0.0014 0.0014*14.61*3*1002=613.46
C3 6.25*2.375=14.61
C4 3.125*2.375=7.30 0.0024(*) 0.0024*7.30*3*1002=528.83
(*) Valores obtenidos mediante interpolacin

b*d = Ac
b: base de la columna
d: peralte de la columna en sentido de sismo

COLUMNA Ac (cm2) BASE (cm) PERALTE (cm)


C1 1051.65 b 25 d 40
C2 613.46 b 25 d 25
C3 613.46 b 25 d 25
C4 528.83 b 23 25 d 23 25

Si la altura del primer nivel es 1.5 veces o ms de la altura de los dems


niveles, entonces se le aade 7cm a los lados de la seccin del primer nivel.

H1/H2 > 1.5

H1: altura del primer nivel


H2: altura del resto de niveles
ANALISIS ESTRUCTURAL

H1/H2 = 4.0/3.0 = 1.33 < 1.5

Por lo tanto no ser necesario sumarle a los lados de la seccin del primer
nivel 7.00cm.

1.5. ESCALERAS

Segn el RNE, Norma E 0.20:

2C + P 0.60m 0.64m
Pmin = 0.25m
Cmax = 0.18m

Entonces asumiremos las condiciones de diseo generales del RNE.

Ancho de escaleras = 1.7m

TRAMO INCLINADO
NIVEL N de C N de P
L (m) t L/20
Primero 3.6/0.1820 20-4=16 16*0.25/2 + 1.7=3.70 0.19
Segundo
Tercero 2.7/0.1815 15-1=14 14*0.25/2 + 1.7=3.40 0.17
Cuarto

TRAMO INCLINADO
NIVEL
= arctg(C/P) cos h = C/2 + t/cos
Segundo
h 0.18/2 + 0.17/0.81
Tercero arctg(0.18/0.25) 35.75 0.81
h 0.30