/ Hybrid Cooling Towers

Cooling Towers without visible plume /

Cooling Technologies
Balcke | Hamon Dry Cooling | Marley
/ Visible plume an avoidable problem /

Every wet cooling tower generates Such plume can, however, lead to
a visible plume which can be very negative reactions such as:
extensive particularly in cold
and/or humid weather. It is the complaints and objections from
physical functioning principle of a local residents
wet cooling tower, in which the
water to be cooled is essentially problems relating to acceptance
cooled by evaporating a small pro- and approval at plant locations
portion thereof, which causes the
plume. When it leaves the cooling corrosion and ice formation on
tower, the visible plume therefore components in the vicinity
consists only of small water
droplets and is normally neither endangering of nearby traffic
dangerous nor environmentally routes (roads and railways) in
hazardous. the case of larger cooling towers

in the case of very large cooling


towers a considerable amount of
shadow is caused in the vicinity
which can have negative effects,
Visible cooling tower plume in for example, on agricultural
most cases harmless but never- areas
theless giving grounds for
complaint, in particular in cold
weather and when there are
traffic routes in close proximity
This was the reason why SPX Normally, cooling with the plume
Cooling Technologies developed being invisible is only possible
the concept of the hybrid cooling when a dry cooling tower without
tower several decades ago. In evaporation is used. This involves,
principle this hybrid cooling tower however, higher capital invest-
is a wet cooling tower in which the ment costs and the cold water
plume is mixed with a dry, hot air temperature achieved are higher
stream prior to leaving the cooling compared to those of a wet cool-
tower. This air stream is generated ing tower.
in heat exchangers, the water to
be cooled serving as the heating Hybrid cooling towers of the SPX
medium. No additional energy is Cooling Technologies design are
The problem: visible plume
therefore required to heat the air. amongst the technically most
The quantity of hot air added advanced cooling towers of this
is such that the plume leaving the type. To date we have built such
cooling tower is undersaturated towers exclusively as round struc-
and remains undersaturated even tures which are best suited to the
when it is mixed with the ambient large flow rates of water to be
air. Consequently it remains cooled (please refer to pages 6/7).
invisible. Some examples of our hybrid
cooling towers are set out on the
following pages.

The solution: SPX Cooling Technologies hybrid


cooling tower

/ Physical functioning principle of a hybrid cooling tower /


air is heated in the dry section
%
j = 95
at a constant level of humidity.
%
=100 4. Mixed air streams from wet and
ne j
uration li
sat dry sections. The air leaves the
dry bulb temperature

cooling tower in this state. The


mixing line (green connecting
saturation line between 1 and 4) distin-
zone guishes the possible degrees to
which the exhaust air is mixed
with the ambient air.
water content 5. Smallest distance between the
mixing line and the saturation
Principle sketch of a hybrid cooling cooling tower). When emerging line (humidity of the air =
tower. The method of operation of from purely wet cooling towers, 100 %) when the air leaving the
a hybrid cooling tower is illustrated this plume mixes with the hybrid cooling tower mixes
in the Mollier h, x-diagram on ambient air. In this case the with the ambient air. If the mix-
the right side. cooling tower plume mixes ing line does not intersect or
with the ambient air along the touch the saturation line, then
1. Ambient air being fed to the mixing line (dotted connecting no water condenses out. In this
cooling tower. line between 1 and 2). case the plume is not visible.
2. Plume leaving the cooling fill 3. Heated air stream leaving the
(the so-called wet section of the dry section heat exchanger. The

3
/ The most frequent design cell-type hybrid cooling towers /

SPX Cooling Technologies hybrid As hybrid cooling towers are


cooling towers of a cell-type primarily used in plants where
design are excellently suited to all disturbing effects on the sur-
types of application, e.g. in power roundings must be avoided, they
stations, chemical plants, refiner- are normally equipped with sound
ies, refrigerating and air-condition- prevention components such as
ing plants etc. They can be made low-noise fans and sound
of different materials such as con- attenuators.
crete, timber, steel, FRP.

Cell-type hybrid cooling tower


with induced draught fan

Fig. 1

Fig. 2

4
Cooling tower made of concrete
for a Spanish paper mill.
Adjustable roller shutter doors can
be seen in front of the heat
exchangers. These control the
required hot air flow rate to ensure
plume-free operation. (Fig. 1)

Hybrid cooling tower made of con-


crete with sound attenuators for a
power station in The Netherlands.
(Fig. 2)

Hybrid cooling tower made of con-


crete and equipped with sound
attentuators for a German chemi-
cal plant. (Fig. 3) Fig. 3

Hybrid cooling tower made of


timber for a British cogeneration
plant. (Fig. 4)

Hybrid cooling tower made of con-


crete and equipped with sound
attenuators for an Austrian com-
bined heat and power station.
(Fig. 5) This plant has separate
forced draught fans for the wet
and dry sections. It is therefore
possible to achieve extremely low
sound emissions on the side of the
cooling tower away from the fans.
As in the case of round cooling
towers, it is possible to control the
wet and dry sections optimally Fig. 4
(please refer to pages 6/7).

Fig. 5

5
/ The top class Hybrid cooling tower of a round design /

SPX Cooling Technologies hybrid towers only one hot water pipe
cooling towers are the ideal solu- leads to the cooling tower whilst
tion for power stations and chemi- in cell-type cooling towers one
cal plants in which large water individual pipe has to be allocated
flows need to be cooled. to each cell.
Recirculation and interference
occur in large cell-type cooling Round hybrid cooling towers have
towers, i.e. the hot cooling tower separate forced draught fans in
plume is sucked back into the air front of the wet and dry sections.
inlets. This significantly reduces Whilst the speed of the wet
the thermal performance of the section fans is adjusted to ensure
cooling tower and additional cells the required cooling water temper-
would have to be built in order to ature, the appropriate speed
Hybrid cooling tower with forced
compensate for the reduction in adjustment of the dry section fans
draught fans
performance. Recirculation and controls the required hot air flow
interference problems are hardly rate for plume-free operation.
ever experienced in round cooling Optimal, energy-saving process
towers due to their greater overall control can therefore be achieved
height. in such cooling towers.

A round hybrid cooling tower also Another positive aspect is the


requires less space than a large architectural design of hybrid cool-
cell-type plant. Finally less piping ing towers.
is needed, as in round cooling
Hybrid cooling towers of a round
design equipped with sound
attenuators for a combined heat
and power station in Germany.
(Fig. 1+2)

Round cooling tower for an Italian


refinery. (Fig. 3)

Hybrid cooling tower of a round Fig. 2


design equipped with sound atten-
uators for a German nuclear
power plant the definite world
champion of its class. (Fig. 4)

Fig. 1

Fig. 3

Fig. 4
/ Key components of a hybrid cooling tower /

/ Heat exchanger quality at / Fans low sound power


the highest level / level but a high degree of
efficiency /

SPX Cooling Technologies heat Low-noise fans are an absolutely


exchangers are produced at the essential component of an envi-
companys own production facili- ronmentally sound hybrid cooling
ties and guarantee the highest tower design.
quality. The production staff can
select from a wide range of materi- The low-noise fan drives and the
als such as C-steel, stainless steel, invisibility of the plume contribute
Fig. 1 nonferrous metal, aluminium in significantly to compliance with
/ Components essential order to provide the appropriate the optical and acoustic require-
to the functioning of a tube material for any medium. ments of environmental regula-
hybrid cooling tower / tions.
C-steel, stainless steel, copper or
Mixing ducts or mixing discs aluminium are used as fin material The low-noise running of the fans
(Fig. 1 and 2) for the finned heat exchanger designed especially by SPX
Low-noise fans (Fig. 3) tubes. When tubes or fins are Cooling Technologies ensures that
Heat exchangers for the dry made of C-steel the finished tubes optimal efficiency is achieved at a
section (Fig. 4) are hot-dip galvanised to protect low sound power level.
Rubber ball cleaning system for them against corrosion.
the inside of the heat exchanger
tubes
Pressurised water cleaning
system for outer finned tube
surfaces
Evacuation equipment
Bypass systems

Fig. 2
Fig. 3 Fig. 4

/ Mixing systems patented tube walls are kept clean during / Bypass systems flexible
efficiency / continuous operation in a large mode of operation /
cooling tower. In cell-type cooling
The mixing systems patented by towers it is preferable to use a In principle it should be possible
SPX Cooling Technologies ensure cleaning fluid. Manual or semi- to operate a hybrid cooling tower
compliance with the guaranteed automatic water jet cleaning purely as a wet cooling tower or
invisibility of plume. Appropriately equipment ensures thorough purely as a dry cooling tower in
designed mixing discs and mixing cleaning of the tube outer sur- order to guarantee 100% avail-
ducts generate the vortices faces/fins. The cleaning equipment ability. To do this, the plant section
required to mix the immense air is used once or twice per year. not in operation must be suitably
flows. Effectiveness and low pres- and reliably bypassed. Controlled
sure drop are the main features of / Evacuation only applied valves in conjunction with over-
these mixing systems. when required / flow weirs ensure absolutely reli-
able operation.
/ Cleaning equipment The syphon-principle mode of
custom-built for easy main- operation has to be applied in
tenance / order to operate the dry section
economically. Accumulation of
A custom-designed heat exchang- inert gases may disturb or inter-
er for the dry section requires an rupt the syphon effect. It may be
appropriate cleaning system in necessary to use evacuation
order to keep the fouling factor as equipment depending on the
low as possible. design and configuration of the
Rubber balls ensure that the inner heat exchanger.

9
/ Automatic process control and instrumentation
Guarantee for optimal operation /

Control panel for a hybrid cooling circuit

When operating hybrid cooling The automatic hybrid cooling The automatic process control for
towers it is extremely important to tower process control developed hybrid cooling towers is designed
ensure optimal adjustment to the by SPX Cooling Technologies and engineered by an experienced
mode of operation so that: which comprises the latest instru- team of experts at SPX Cooling
mentation and control technology Technologies who are well-versed
operation is plume-free irrespec- including Programmable Logic in cooling tower operation and
tive of the changing ambient Control (PLC) systems guarantees: have specific technical expertise
meteorological conditions in instrumentation and control
the cooling water temperatures fully automatic operation to technology.
being a function of the cooling ensure invisibility of plume or
water flow rate, the heat rejec- minimum plume Upon request, we can also supply
tion rate and the changing maximum profitability with optimal automated process control
ambient air conditions are as minimal power consumption for the entire cooling circuit.
required maximum reliability and
power consumption of the cool- availability of the plant
ing tower fans is minimised minimal personnel expenses

10
/ Teamwork for the benefit of our customers /

/ Together we are strong / / On the spot with good


advice and assistance /

Specialists for thermodynamics, This gives you an insight into


hydraulics, instrumentation and hybrid cooling towers. If you have
control, structural engineering and any questions or require informa-
civil engineering work together in tion from us about any specific
our interdisciplinary engineering problems relating to cooling sys-
teams. tems just phone us or write to us.

Our company Research and Us being SPX Cooling Technol-


Development Centre is fitted with ogies GmbH or our affiliated com-
state-of-the-art equipment and panies in Europe and overseas.
employs a highly qualified staff to We are always open to learn about
meet your requirements. interesting problems facing our
customers. And in most cases we
We are also in contact with can provide the solution. Because
colleges of advanced technology tricky cases are our speciality.
and universities to exchange infor- Challenge and obligation in one.
mation on a regular basis. Your
assignments, even unusual prob-
lems are in the very best of hands
at SPX Cooling Technologies.
Your competent partner.
/ Worldwide Competence in Cooling /

Manufacturing Units
Representatives/Agents
SPX Cooling-Units