APPLICATIONS
Gear set capacity
(see pump capacity curves)
- Light, medium and heavy oil.
- One or two-pipe system. Strainer
- Normally associated with in-line solenoid valve. C : 170 m
N : 550 m
Vacuum
Inlet
Oil under suction gauge port
Back
to suction
Pressure
To nozzle
adjustment
Pressure
By-pass By-pass gauge port
plug plug
removed inserted
Return ONE PIPE TWO PIPE
plugged INSTALLATION INSTALLATION Return
SUNTEC INDUSTRIES FRANCE - 1, rue Lavoisier - BP 102 - F-21603 LONGVIC Cedex - Tel. 33 (0)3 80 70 60 70 - Fax 33 (0)3 80 70 61 11- www.suntec.fr
TECHNICAL DATA Pump capacity
Capacity (L/h)
400
General
350 E7
Mounting Flange mounting according to EN 225.
Connection threads Cylindrical according to ISO 228/1
Inlet and return G 1/2 300
Nozzle outlet G 1/4
200
100
10 15 20 25 30 35
Pressure(bars)
Viscosity = 75 cSt
20 cSt
5 cSt - Rated speed = 2850 rpm
88 80 99
48 92
24
Suction or
Pressure
vacuum gauge port
gauge port
28
91
A
41 54 10,5
Return and Vacuum
A 128
internal gauge port
47 or suction
by-pass plug
A-A Nozzle outlet Pressure
10 adjustment
22 11,07
37 59 max 43
We reserve the right to change specifications without prior notice. E 1001 - 11 - Ed 12 - July 2009