Abstract
A modied scanning Kerr microscope has been used as a static Kerr magnetometer to acquire in-plane vector hysteresis loops from
square Si/Ta(50 A)/Co80Fe20(40 A)/Ni88Fe12(108 A)/Ta(100 A) elements with size ranging from 123 nm to 10 mm. The nanoscale elements
were arranged in square arrays of 4 mm size. The laser beam was focused to a sub-micron spot, while polarization changes were recorded
with an optical bridge detector containing a beam-splitting polarizer and two quadrant photodiodes. The coercive eld exhibited a non-
monotonic increase from 11 Oe in the 10 mm element to 170 Oe in the 123 nm elements. Loops acquired with the eld applied parallel to
the easy and hard in-plane uniaxial anisotropy axes were observed to become more similar in shape as the element size decreased.
r 2006 Elsevier B.V. All rights reserved.
Nanoscale ferromagnetic elements are required to microscale samples fabricated by e-beam lithography and
achieve increased storage densities within magnetic data samples integrated with microscale waveguides require a
storage technologies [1]. Magnetometry measurements microscale probe. In this work we demonstrate static,
provide the most direct means by which to quantify their focused Kerr magnetometry measurements that allow
magnetic parameters and investigate their micromagnetic hysteresis loops for both components of magnetization
state. Indeed knowledge of the magnetic ground state is a within the sample plane to be measured simultaneously.
prerequisite for understanding the spin wave spectrum [2] We have performed measurements upon micro-arrays of
and hence dynamic properties such as precessional switch- nano-magnets, which require high sensitivity, due to the
ing [3] that may lead to higher data rates. Magnetometry low areal density of the nano-magnets within the arrays.
studies of nanoscale elements have been performed with a Excellent mechanical stability is also necessary so that the
superconducting quantum interference device [4] and an spot remains focused at the center of the array as the
alternating gradient magnetometer [5]. However, arrays of magnetic eld is ramped up and down.
size 1 cm2, consisting of 106 elements of length 100 nm In this study measurements have been made using a
and lm thickness 50 nm, were required to produce scanning Kerr microscope [12] of sub-micron spatial
adequate signal. The magneto-optical Kerr effect (MOKE) resolution that is equipped with a compact optical
[6] has been used to investigate the effect of congurational quadrant bridge polarimeter. While quadrant optical
anisotropy [7,8], inter-element separation [9,10] and ex- bridge detectors have been used previously to image
change bias effects within arrays of nanoscale elements [11] domain structures [12] and study precessional switching
that are typically tens of microns in size. However, isolated within microscale elements [3], measurements of in-plane
vector hysteresis loops were not routinely reported.
Corresponding author. Tel.: +44 1392 264152; fax: +44 1392 264111. Measurements were made upon single microscale ele-
E-mail address: p.s.keatley@exeter.ac.uk (P.S. Keatley). ments and arrays of nanoscale elements. The arrays were
0304-8853/$ - see front matter r 2006 Elsevier B.V. All rights reserved.
doi:10.1016/j.jmmm.2006.03.030
ARTICLE IN PRESS
P.S. Keatley et al. / Journal of Magnetism and Magnetic Materials 306 (2006) 298301 299
(a+b)(c+d)
(c+d)(a+b)
Kerr rotation (Arb. units)
0.0 10 428 nm
-0.5 8 637 nm
(a+d)(b+c)
(b+c)(a+d)
0.5 2 6 m
0.0
0 10 m
-0.5 (a) (b)
-2
-1.0 (b) (c) -400 0 400 -400 0 400
Applied magnetic field (Oe)
-40 -20 0 20 40 -40 -20 0 20 40
Applied magnetic field (Oe) Fig. 4. M|| easy (a) and hard (b) axis loops for all elements.
Fig. 2. Hard axis M|| (a) and M? (b) hysteresis loops are shown for sheet
material. M|| (c) and M? (d) sensed by orthogonal halves of the focused
laser beam when the sample and H are rotated through 901.
175 Nanoscale element arrays
Single microscale elements
150
Easy axis Hard axis
Coercive field (Oe)
1.0 125
M M||
(a+b)(c+d)
(c+d)(a+b)
0.5 100
0.0
Kerr rotation (Arb. units)
75
-0.5
-1.0 (a) (d) 50
1.0
M|| M
25
(a+d)(b+c)
(b+c)(a+d)
0.5
0.0 0
0.1 1 10
-0.5
Element length (m)
-1.0 (b) (c)
Fig. 5. Evolution of the measured coercive eld of easy axis M|| loops as
-200 -100 0 100 200 -200 -100 0 100 200
the element size is reduced.
Applied magnetic field (Oe)
Fig. 3. Easy and hard axis M|| and M? hysteresis loops are shown for a
10 mm single square element. Measurable M? signals were obtained from the three
largest single elements only (shown only for the 10 mm
element in Figs. 3a and c). The loops in Fig. 4 were
magnetic eld applied parallel to the easy and hard axis obtained in the same manner as the M|| loops of the 10 mm
directions. The easy axis M|| loop is sensed by the half element. The loops shown in Fig. 4a reveal a non-
(a+d)-(b+c) and has square shape (Fig. 3b). The M? monotonic increase in coercive eld from 11 Oe in the
loops sensed by the half (a+d)-(b+c) reveal spikes 10 mm single element to 170 Oe in the 123 nm element array.
that are correlated with the switching eld in the M|| loop A change from a higher coercive eld in the 2 mm single
(Fig. 3a). When the eld is applied parallel to the hard axis, element to a lower coercive eld in the 637 nm element
hysteresis loops with shape similar to those in Figs. 2c and array is observed, as shown for the easy axis loops in
d are obtained. However the hard axis loops for the 10 mm Fig. 5. A similar change is observed for the hard axis loops
element have larger saturation and coercive eld. This may (Fig. 4b). One striking feature of the loops obtained from
be attributed to dipolar elds and pinning sites associated the nanoscale elements in arrays is that the shapes of the
with the edges of the element. Discrete jumps (indicated by easy and hard axis loops are very similar, while for the
arrows) are well correlated between the M|| and M? loops single elements there remain signicant differences between
and suggest the occurrence of domain wall motion. the loop shapes. For example, the easy and hard axis
Fig. 4 shows easy and hard axis M|| hysteresis loops remanent magnetization for the 10 mm element is 100%
acquired from the single elements and element arrays. and 60%, respectively, while the remanence for the
ARTICLE IN PRESS
P.S. Keatley et al. / Journal of Magnetism and Magnetic Materials 306 (2006) 298301 301
124 nm element is 60% for both anisotropy axes. have demonstrated that the vector magnetization may be
Furthermore, asymmetric switching events are seen for sensed. Comparison of hysteresis loops obtained from
the hard axis loops obtained from the three largest different element sizes have revealed an increase in the
elements, while the ve smallest elements exhibit a coercive eld as the element size is reduced, which has been
symmetric hysteresis loop shape. In addition the loops discussed in terms of the modied dipolar elds and
obtained for the easy axis are symmetric for all elements additional pinning sites within the elements. This work
measured, further demonstrating a greater similarity demonstrates that a scanning Kerr microscope equipped
between easy and hard axis loops shape for the smaller with a quadrant polarization bridge detector is a powerful
elements than for the larger elements. The sudden tool for the characterization of nano-magnet arrays of very
reduction in coercive eld between 2 mm and 637 nm, and small area.
the similarity of the easy and hard axis loop shapes for the
nanoscale elements in arrays, may indicate a transition The authors gratefully acknowledge the support of the
from domain wall motion to incoherent rotation.
UK Engineering and Physical Sciences Research Council
There are many factors that may affect the hysteresis
(EPSRC) and the New Energy and Industrial Technology
loop shape. Inter-element dipolar interactions within
Development Organisation (NEDO).
arrays may signicantly modify the hysteresis loop shape
with respect to the single element, e.g. by reducing the
coercive eld. Loops for 637 nm elements with an edge-to- References
edge separation of 234 nm are also shown in Fig. 4a (open
[1] A. Moser, K. Takano, D.T. Margulies, M. Albrecht, Y. Sonobe, Y.
circles) and show that the coercive eld increases with Ikeda, S. Sun, E.E. Fullerton, J. Phys. D: Appl. Phys. 35 (2002) R157.
increased element separation. We ascribe the similarity of [2] V.V. Kruglyak, A. Barman, R.J. Hicken, J.R. Childress, J.A. Katine,
easy and hard axis hysteresis loops shape to the increased Phys. Rev. B 71 (2005) 220409(R).
non-uniformity of the magnetization reversal process in the [3] W.K. Hiebert, G.E. Ballentine, M.R. Freeman, Phys. Rev. B 65
four smallest elements. This is in contrast to the coherent (2002) 140404(R).
[4] J.F. Smyth, S. Schultz, D. Kern, H. Schmid, D. Yee, J. Appl. Phys. 63
rotation mechanism observed in the hysteresis loops of the (1988) 4237.
continuous lm and largest elements. The non-uniform [5] J.F. Smyth, S. Schultz, D.R. Fredkin, D.P. Kern, S.A. Rishton,
reversal process occurs when the dipolar energy becomes H. Schmid, M. Cali, T.R. Koehler, J. Appl. Phys. 69 (1991) 5262.
more signicant than the exchange energy. The difference [6] S.D. Bader, J.L. Erskine, in: J.A.C. Bland, B. Heinrich (Eds.),
between the easy and hard axis behavior is reduced further Ultrathin Magnetic Structures II, Springer, Berlin,Heidelberg, 1994
(Chapter 4).
due to pinning at edge defects that occurs irrespective of [7] M.E. Schabes, H.N. Bertram, J. Appl. Phys. 64 (1988) 1347.
the applied eld direction. The latter effect is again more [8] R.P. Cowburn, A.O. Adeyeye, M.E. Welland, Phys. Rev. Lett. 81
signicant in the smallest elements. The random occurrence (1998) 5414.
of defects leads to slanting of the hysteresis loops as the [9] C. Mathieu, C. Hartmann, M. Bauer, O. Buettner, S. Riedling,
B. Roos, S.O. Demokritov, B. Hillebrands, B. Bartenlian,
element length is decreased due to the distribution of
C. Chappert, D. Decanini, F. Rousseaux, E. Cambril, A. Muller,
switching elds present in the ensemble of elements. B. Hoffmann, U. Hartmann, Appl. Phys. Lett. 70 (1997) 2912.
Further measurements are required to isolate the effects [10] S.M. Weekes, F.Y. Ogrin, P.S. Keatley, J. Appl. Phys. 99 (2006)
of these different mechanisms. 08B102.
In summary, vector magnetic hysteresis loops have been [11] V. Baltz, J. Sort, S. Landis, B. Rodmacq, B. Dieny, Phys. Rev. Lett.
obtained from continuous sheet material, individual 94 (2005) 117201.
[12] W.W. Clegg, N.A.E. Heyes, E.W. Hill, C.D. Wright, J. Magn. Magn.
microscale square elements and 4 mm arrays of nanoscale Mater. 95 (1991) 49.
square elements using a scanning Kerr microscope of sub- [13] E.C. Stoner, E.P. Wohlfarth, Philos. Trans. R. Soc. London A 240
micron spatial resolution. Measurements on sheet material (1948) 597.