1 General
A "Schindler Smart retrot kit" is available for converting existing systems of the "Schindler Smart"
type to frequency inverter type ZETADYN 4C.

Contents of the "Schindler Smart" retrot kit:


1x relay module type PR1-RSC3-LV-120VAC/21AU for travel direction setting (K5 ) (Article No.
00165434)
2x relays type 35.51.3 (110 VAC) for additional monitoring of the motor contactors (K-CO1 + K-
CO2) (Article No. 00165439)
Incremental counter type ET2S-1024/28/05V-15 (Article No.. 02014700)
Adapter with M16 thread for incremental counter type ET2S-1024/28/05V-15 (Article No.
01009620)

The frame size of the ZETADYN 4C must be selected dependent on the motor data of the motor in the
system.
The ZETADYN 4C has special software for lift systems of the "Schindler Smart" type.

Requirements for successful replacement


1. Voltage of the safety circuit = 110 VAC
2. The frequency inverter must be controlled by digital signals. If the existing frequency inverter is
controlled by a bus connection, it is not possible to convert to a ZETADYN 4C.
3. The system should be converted to operation with a rotary encoder. This improves the travel
comfort and stopping accuracy.

2 Electrical installation
Danger!
It is forbidden to carry out work on the frequency inverter when it is live.
Even after disconnection, the DC-link ( terminals X2: +DC / X2:-DC ) are still live.
Wait at least 3 minutes before working on the device

Danger!
It is not permitted to operate the ZETADYN 4C with the housing covers removed, as exposed live
parts are present inside the frequency inverter. Failure to observe this provision can lead to serious
injury.

Work on electric components may only be carried out by trained electricians or by persons instructed
in electricity under the supervision of an electrician in accordance with electrical engineering regula-
tions.

A second person must always be present when working on energized parts or lines who disconnects
in case of emergency.

Inspect electrical equipment periodically: retighten loose connections immediately replace damaged
lines and cables.
Always keep switch cabinets and all electrical supply facilities locked. Access is only allowed for
authorized persons using a key or special tool.

R-TIA14_08-GB 1439 Part.-No. 00163424-GB


Technische Information Electrical installation

Power supply connection 3~ 400 VAC (X1)

Schindler switch cabinet ZETADYN 4C


L1-A X1:L1
L2-A X1:L2
L3-A X1:L3
PE-A X1:PE

Motor contactor connection (X3)

Motor contactors ZETADYN 4C


SR-D:1 X3:U
SR-U:1
SR-D:3 X3:V
SR-U:3
SR-D:5 X3:W
SR-U:5
PE X1:PE

The existing wiring of SR-U must be changed:


SR-D:1 -> SR-D:5
SR-D:5 -> SR-D:1

Changing the wiring

Brake resistor connection (X2)

Brake resistor ZETADYN 4C


+DC X2:+DC
R X2:R
TB1 X-MON:5 (+24V_BC)
TB2 X-MON:6 (BC)
PE X2:PE

Digital inputs connection (X-IN)

Schindler switch cabinet ZETADYN 4C Function


X-FCL:5 X-IN:2 (24V_IN) 24 V external
K5:11 X-IN:2 (24V_IN) Relay travel direction setting
X-FCL:6 X-IN:3 (I01) RF
X-FCL:9 X-IN:4 (I02) V1
X-FCL:10 X-IN:5 (I03) LZ
X-FCL:8 X-IN:6 (I04) V3
X-IN:4 X-IN:7 (I05) V4
K5:12 X-IN:8 (I06) RV1 (UP)
K5:14 X-IN:9 (I07) RV2 (DOWN)
X-IN:10 (I08) not used
X-FCL:11 X-OUT:7 (O41) X-IN:11 (GND_IN) Ground external

R-TIA14_08-GB 1439 Part.-No. 00163424-GB


2/8
Technische Information Electrical installation

Digital outputs connection (X-OUT)

Schindler switch cabinet ZETADYN 4C Function


X5:1 X-OUT:1 (O11)
ST
X5:3 X-OUT:2 (O14)
X-FCL:1 X-OUT:3 (O21)
MB_Brake
X-FCL:3 X-OUT:4 (O24)
X-IN:11 (GND) X-OUT:7 (O41)
SD
X-FCL:7 X-OUT:8 (O44)

Travel direction setting relay connection (K5)


The additional relay for controlling the travel direction setting is mounted in the control switch cabinet.

Relay Schindler switch cabinet ZETADYN 4C


K5:A1 XBAR:7 / XCTR:4
K5:A2 XCOIL:2 / XCTR:1
K5:11 X-IN:2 (24V_IN)
K5:12 X-IN:8 (I06)
K5:14 X-IN:9 (I07)

Motor contactor monitoring relay connection (K-CO / X-MON)

Relay Schindler switch cabinet ZETADYN 4C


K-CO1:A1 SR-U:A1
K-CO2:A2 SR-U:A2
K-CO1:11 X-MON:1
(+24V_CO)
K-CO1:14 X-MON:2 (CO1)
K-CO2:A1 SR-D:A1
K-CO2:A2 SR-D:A2
K-CO2:11 X-MON:1
(+24V_CO)
K-CO2:14 X-MON:2 (CO1)

Deactivation contactorless operation (X-STO)


Since the system is still being operated with motor contactors, the inputs for controlling the contactor-
less operation must be activated permanently.

X-STO
+24V_
STO (6)

GND (5)

STO_A (4)

GND_
STO (3)

STO_B (2)

(1)

STO connection bridged

R-TIA14_08-GB 1439 Part.-No. 00163424-GB


3/8
Technische Information Electrical installation

Connection diagram

ZD4C01K7

R-TIA14_08-GB 1439 Part.-No. 00163424-GB


4/8
Technische Information Startup / conguring ZETADYN 4C

3 Startup / conguring ZETADYN 4C


Startup takes place in the Startupmenu.

Be careful with the motor data!


Do not enter the original speed (e.g. 1,500 rpm) in the ZETADYN 4C.

Parameter Description Parameterisation


LCD Operating language Desired operating language
USR_LEV User level Basic
MOT_TYP Motor type ASM
n Rated speed of the motor
f Rated frequency of the motor
I Rated current of the motor According to motor name plate
U Rated voltage of the motor ATTENTION: Do not enter the syn-
chronous speed of the motor as the
p Rated power of the motor
nominal speed!
cos phi Power factor of the motor
TYP Connection type of the motor
ENC_TYP Used encoder TTL Sine
ENC_INC Resolution encoder 1024
BC_TYPE Used brake resistor According to name plate of brake
resistor
V* Rated speed of installation Desired speed of installation
_D Diameter of the traction sheave Diameter of used traction shea-
ve[mm]
_iS Suspension 2:1
_i1 Gear box ration i1
According to name plate of gear box
_i2 Gear box ration i2
CONFIG Way of communications 32:S_SMART
MO_DR Motor direction Depending on travel direction of
cabin
CO Contactor monitoring CO1
BR Monitoring of the motor brakes Off
P1P2 Motor temperature monitoring Off
K_Start Amplication of speed controller at Dependent on travel behaviour
start
SPD_KP Amplication of speed controller Dependent on travel behaviour

Due to the parameterisation CONFIG= 32:S_SMART following pre-conguration will be carried out:
Output O4: function SD
Input I2: function LZ
Parameter V_G1 = 0,15 m/s (limit value for output function SD)
S_10= 50 mm (deceleration distance V1 to standstill

Deactivation of STO function


Since the system is still being operated with motor contactors, the monitoring of the STO function
(contactorless operation) must be deactivated.
Deactivation takes place in the Monitorings/STO=Offmenu.
Monitors
-" STO
|
Off
|
-" Off
STO monitor

Keep the ESC key pressed for approx. 5s to open the menu.

R-TIA14_08-GB 1439 Part.-No. 00163424-GB


5/8
Technische Information Process of Deceleration

Activating inspection speed


The speeds V1 and V4 will be actuated parallel.
V4 is used for inspection speed. The speed of V4 can be changed in Menu TravelingFahren/V4.

Behaviour of ZETADYN 4C:

Start of travelling with: Acceleration to: Deactivation of: Deceleration to:


V1 V3 V4
V3 V3 V1
V4 V1 + V4 Emergency stop

4 Process of Deceleration
Important for an error-free deceleration and positioning of the cabin are the signals SD LZ.

Function positioning speed is reached (SD)


Output O4 with function SD will be activated depending on the parameter V_G1 (0,15m/s)
1 Only with this signal the elevator control is able to recognise the door zone.
If this signal is not available the cabin will not stop ush to the oor and an emergency stop will be
carried out.
Function door zone reached (LZ)
Input I3 with function LZ will be activated.
2
Although V1 is still activated, a deceleration within the distance, preset by parameter S10(50mm),
will be carried out.
3 20 ms after the motor contactors have open, output O4 with function SD will be switched off.

1 3

R-TIA14_08-GB 1439 Part.-No. 00163424-GB


6/8
Technische Information Process of Deceleration

R-TIA14_08-GB 1439 Part.-No. 00163424-GB


7/8
by Ziehl-Abegg - - 00163424-GB - 1439 - - Subject to technical changes

Customer Service
phone +49 7940 16-308
fax +49 7940 16-249
drives-service@ziehl-abegg.com

Headquarters
ZIEHL-ABEGG SE
Heinz-Ziehl-Strae 74653 Knzelsau
Germany
phone Tel. +49 (0) 7940 16-0 fax Fax +49 (0) 7940 16-249
drives@ziehl-abegg.de www.ziehl-abegg.com

Das könnte Ihnen auch gefallen