MasterSeal Systems
Engineered sealing and
weatherproofing solutions
2 MasterSeal Systems
Properties, ch
Elongation at break %
Non-Sag / Gun grade
Elastic recovery %
Shore A hardness
Sausage (600 ml)
Fluid SL grade
Movement
Product Sealant type
Neutral cure
MasterSeal 122 silicone
Y N Y N 25 16 0.35 >90 500
1 component
MasterSeal NP 472 polyurethane
Y Y Y N 25 35 0.202 >85 700
1 component
MasterSeal NP 474 polyurethane
Y Y Y N 25 45 0.602 >85 450
Neutral cure + 50
MasterSeal SL 189 silicone
Y Y N Y
- 25
15 <0.20 >85 1000
1 component
MasterSeal HY 495 hybrid
Y Y Y N 25 25 0.35 >80 350
Acrylic
MasterSeal 10WB dispersion
Y N Y N 7.5 <15 n/a n/a 200
2 component + 10
MasterSeal CR 460 polyurethane
N N N Y
to 20
80 1.80 n.a. >20
MasterSeal Systems 3
Chemical resistance
Water immersion
Swimming pools
Industrial floors
Sanitary / tiling
Natural Stone
Facades
Roads
International Standards
EN15651_1: F-EXT-INT-CC
- 30 to
0.38 VG 2.5 Y N Y Y N N N 25LM, ISO 11600 F25LM, ASTM
+ 70
920
- 20 to EN 15651 Part 1:
0.38 N/A 2 N N N N N N N
+ 75 F-EXT-INT 7,5P
MasterSeal 955
FLASHSEAL self-adhesive
instant waterproofing tape
MasterSeal 121,
MasterSeal 122,
MasterSeal 123NS, or
MasterSeal NP 472 for
balcony waterproof joints
in tiled systems
MasterSeal waterproofing
and MasterTile tile
adhesives and grouts,
engineered solutions for
swimming pools
1
Product ranges may vary in different countries
MasterSeal Systems 5
MasterSeal NP 472 or
MasterSeal HY 495 roof
joints
MasterSeal NP 472
or MasterSeal HY 495
sealants for watertight
facade joints
MasterWeld 303
construction adhesive for
fixing frames, skirtings,
panels architectural
details
MasterSeal 10WB,
MasterSeal 122 and
MasterSeal NP 472 for
corner bead joints on
window and door frames
Special properties
MasterSeal 122: neutral cure ensures odorless installation
and ability to be used on cement, concrete and other
alkaline substrates. High polymer content allows use in tiled
swimming pools.
MasterSeal 123NS: 100% silicone odorless, formula to
eliminate staining on Natural and Reconstituted Stone floor
and wall coverings.
MasterSeal Systems 7
MasterSeal 122 with MasterTile tile adhesives and grouts: the ideal engineered solution for tiled swimming pools
Application
Concrete, brickwork,
Bathrooms and wet
Swimming pools
Neutral cure
Acid cure
floor tiles
kitchens
renders
frames
rooms
wood
Product
MasterSeal 121 Y N Y Y Y N Y y N y
MasterSeal 122 N Y Y Y Y Y Y Y y Y
MasterSeal 123NS N Y Y Y Y y y y Y y
Color
Mahogany Brown
Concrete Grey
(RAL 9010)
(RAL 1015)
(RAL 7004)
(RAL 7035)
(RAL 8016)
(RAL 1036)
Light Ivory
Light Grey
Bronze
White
Black
Clear
Product
MasterSeal 121 Y Y Y Y Y Y Y Y
MasterSeal 123NS N Y Y Y Y N N N
Y = Yes (Recommended)
N = No
y = yes (but better alternatives available)
8 MasterSeal Systems
Color
Application /
Low strength substrates
Color
Off white (RAL 1015)
Floors / traffic joints
Tilt up construction
Moisture tolerance
construction joints
V. Low isocyanate
Precast panels
Primer needed
Concrete Grey
(RAL 7004)
Product
MasterSeal NP 472 N1 Y Y Y y Y N N N Y Y Y
MasterSeal NP 474 N1 Y Y Y y N N Y2 N Y Y Y
MasterSeal HY 495 N1 Y Y Y Y Y Y y Y Y Y Y
Notes:
1 = on most substrates
2 = with primer
10 MasterSeal Systems
MasterSeal CR 460
Special, 2 component formulation with exceptional
chemical resistance for use in food, beverage and
pharmaceutical industries.
Color matched to 7 standard colors of Ucrete floor systems.
MasterSeal Systems 11
Construction joints
Colors available
Fuel resistance
Primer needed
High chemical
resistance 3
surfaces
hangars
joints
Product
MasterSeal SL 189 1 N1 Y Y Y Y y N Y Y N Grey
MasterSeal CR 460 2 Y y2 Y Y N Y Y N N Y 73
Notes:
1 = On most substrates
2 = Limited movement ( 20%)
3 = See Ucrete product data sheets or contact BASF representative
Fire and acoustic rated sealants for MasterSeal FP 125: Single component, elastic, weatherproof,
compartmentation / passive fire protection1 240 minute fire rated silicone sealant for joints up to 50 mm
A very special range of products, with acoustic, flame and fire wide.
retardant properties, used as part of passive fire protection
systems in buildings and structures. Full details of the products MasterSeal FP 115: Graphite filled, high pressure exerting,
can be found in the separate product data sheets and brochure. intumescent joint sealant which owing to its very high expansion
properties is able to close penetration voids in case of fire.
MasterSeal FP 110: Single component, acrylic plasto/elastic
sealant with sound reducing, and fire and smoke retardant Note 1: Due to local registration restrictions these products may
not be available in your country. Contact your local Master Builders
properties (120 minutes).
Solutions representative for clarification.
12 MasterSeal Systems
Joint design
All structures move. Correct design of joints allows controlled movement to occur while retaining the weather and watertight
functionality of the structure. Movement occurs as a result of long term shrinkage of concrete, settlement, loading, vibration, and
impact, but, the most important source of movement, results from temperature change. Even the best quality joint sealants, applied
by trained installers will fail if joints are not correctly designed.
L = x L0 x T
L = Resulting change in length
= Coefficient of Thermal Expansion of the material (Typically concrete = 12.5 x 10-6 m/m)
L0 = Original length of the building element
T = Net change of temperature in the element
Example: Consider 2 concrete elements each 10 m long (see diagram below). Extreme temperatures: -5C winter, +45C in
summer. Therefore, the movement is calculated using the equation above, as:
10 meters 10 meters
Fixed ends
Potential movement at butt joint = 2 x 6.25 mm = 12.5 mm (for a temperature change of 50C)
Note: BASF take no responsibility for design of joints. This information is provided as a guide only.
MasterSeal Systems 13
The minimum theoretical joint width is calculated based on the calculated movement and the movement capability of the joint sealant:
Therefore, in the above example, and using MasterSeal NP 472 with a movement capability of 25% = 50% total movement
capability
But, beware, this theoretical minimum calculation can cause significant problems if we do not consider the temperature at the
time of the installation of the joint sealant, and the ACTUAL size of the joint at this time!
Consider, as an example, if the structure is built in spring at a temperature of 10C, with the 25 mm joint width as calculated.
But the sealant is not installed until late summer when the ambient temperature is then 40C. Both the concrete elements will
have expanded by 3.25 mm and the joint will have closed by 7.5 mm to an actual width of 17.5 mm. Most of the potential
movement of the joint will be as the concrete shrinks over winter time to -5C. This 45C temperature change will cause the
joint gap to widen by 11.25 mm.
11.25 mm as a percentage of 17.5 mm = 64.3% movement far greater than the 25% movement capability in expansion of the
sealant which could, over time lead to cohesive or adhesive failure either in the sealant or substrate.
For these reasons, use of a Safety factor of 2 is recommended when designing joint widths (or use twice as many joints, if
aesthetics allow).
However,
for joints > 12 mm wide the joint depth should equal 0.5 x
width.
1 2 3
4 5
MasterSeal Systems 15
1 2 3 4
16 MasterSeal Systems
Glossary of terms
Substrates 100% Modulus (E-Modulus)
The composition of the building material. Adhesion properties Measures the force necessary to stretch a standard sample
of sealants vary on different substrates. Primers might be to twice its original length. Materials with high modulus
required to assure good adhesion. The correct require greater force to achieve a certain elongation. On weak
preparation and repair of substrates are essential for the substrates such as masonry or EIFS panels, the high stresses
sealant durability. generated by higher modulus sealants often cause cohesive
failure in the substrate, or adhesive failure at the bond line on
Elastic recovery stronger substrates such as concrete. temperatures, when
This test measures a sealants recovery after it has been materials become stiffer, and even greater force is necessary
extended for a certain length and time. The results represent to achieve elongation, or when the substrates to be sealed are
the percentage recovery in relation to the length of extension. too weak, low modulus sealants should be used. N.B. Modulus
High percentage recovery show that a sealant experiences data from different manufacturers can only be compared
less permanent plastic deformation and retains its flexibility when identical test methods have been used, as sample size,
and functionality over time. thickness and rates of extension all affect the results obtained!
Silicones
Versatile material used in a wide range of applications
characterized by excellent UV resistance and bond to most
substrates without primers. Widely used in structural glazing
applications but these specialist materials are not included in
the MasterSeal range.
Polyurethanes
For many years the workhorse sealant and adhesive material
for construction and industrial applications. With good
performance characteristics in all fields, they are used in a
very wide range of situations.
Hybrid materials
The latest technology, combining the best features of silicone
and polyurethane polymers in one polymer. They exhibit
excellent adhesion characteristics and UV resistance, and
high tolerance to dampness, without formation of bubbles,
which is a known limitation of polyurethanes. Two terms are
widely used in the industry:
MS polymer (Modified silicone)
SPUR or StPUR (silane or silicone terminated polyurethane).
These are essentially the same technology.
Polysulfides
Long established with a proven track record in the sealant
market with excellent resistance to fuel and chemicals.
18 MasterSeal Systems
MasterSeal 940
Internally and externally placed, high grade PVC waterstops
for expansion and construction joints provide impervious
physical barriers to the passage of water. Used for
compartmentalization in deep basements, lift shafts, floor
slabs on grade, reservoirs, watertanks etc.
MasterSeal 930
Elastic, resilient, chemical resistant tape fixed with high
grade solvent free epoxy adhesive paste, ideal for the sealing
of irregular and wide movement joints in a wide range
of applications such as reservoirs, watertanks, irrigation
channels, waste water storage.
MasterSeal Systems 19
MasterTile WP Tapes
Elastic, tape system used to ensure watertight connections
at wall/floor joints and around penetrations in bathrooms and
other wet rooms. Used with the BASF system solution for
watertight bathrooms.
United Arab Emirates: BASF CONSTRUCTION CHEMICALS UAE LLC Kenya: BASF EAST AFRICA LIMITED Ukraine: BASF T.O.V.
Dubai: +971 4 8090800 Abu Dhabi: +971 2 5512262 Tel: +254 20 4443454 www.master-builders-solutions.basf.co.ke Tel: +380 44 5915595 www.master-builders-solutions.basf.ua
www.master-builders-solutions.basf.ae
Morocco: BASF MAROC SA Singapore: BASF SOUTH EAST ASIA PTE. LTD
Regional Offices Tel: +212 522 669939 www.master-builders-solutions.basf.co.ma Tel: +65 6861 6766 www.master-builders-solutions.basf.com.sg
Bahrain: +973 1 7786427
Near East: JORDANIAN SWISS COMPANY FOR MANUFACTURING
AND MARKETING CONSTRUCTION CHEMICALS Malaysia: BASF (MALAYSIA)
Qatar: +974 4 4114870
www.master-builders-solutions.basf.qa Tel: +234 1 460483 www.basf-cc.com.jo Tel: +603 5628 3888 www.master-builders-solutions.basf.com.my