Sie sind auf Seite 1von 2

ebm06086_4seiter_engl 13.02.

2007 15:27 Uhr Seite 1

Art.-Nr. 01473.60058
Subject to technical modifications.
The revolutionary
LambdaConstant System

In choosing the LambdaConstant System made by ebm-papst, manufacturers of gas condensing


boiler heating systems are acquiring a one-of-a-kind and cost-effective technology, which will
be available by mid 2007. Naturally we can adapt the control system electronics to meet the
individual requirements of your applications. Contact us today about your needs and to obtain
information on all of the essential details. We are glad to be of assistance.

ebm-papst Landshut GmbH

Hofmark-Aich-Strae 25
D-84030 Landshut, Germany
Phone +49 (0) 871 / 707-0
Fax +49 (0) 871 / 707-465
info3@de.ebmpapst.com

www.ebmpapst.com

New independence in condensing


boiler technology
ebm06086_4seiter_engl 13.02.2007 15:27 Uhr Seite 11

Optimum combustion always and everywhere

The launch of a world first: the LambdaConstant System by ebm-papst, a revolution in condensing boilers. Consisting of an
intelligent ebm-papst blower and control unit, the LambdaConstant is the first system ever to adjust automatically to optimum
combustion, always, even where variable gas types are present. And this it achieves entirely independent of the location of use
and the present conditions, such as air pressure or the length of the flue gas tract.
With the LambdaConstant System, our customers are opting for a new, currently one-of-a-kind technology in the heating
industry with intelligent control and equally robust components that will generate upper heating values ruggedly and reliably
throughout the entire service life. See for yourself!

Always at optimun combustion regardless of the type of gas Always energy-efficient thanks to a one-of-a-kind degree of
The LambdaConstant System makes condensing boilers entirely inde- modulation
pendent of different types of gas. Up to now, devices have required time- New condensing boiler technology with the built-in LambdaConstant
consuming adjustment and calibration based on various types of gas. System achieves modulation of unprecedented levels: 1:10 compared to
The LambdaConstant System now eliminates these tasks by adjusting 1:4 using conventional technology. This vastly improves the efficiency
automatically to the type of gas. In markets with variable gas composi- and environmental cleanliness of the gas therms. Thanks to the high
tions, the LambdaConstant System ensures, for the first time ever, modulation range, a vast variety of output requirements from low heat
optimum and constant combustion. output needs to full power output for hot water supply can be met with
precision.
Always at maximum output regardless of the location of use
The actual maximum output of condensing boilers depends greatly on As easy as it is resourceful the functionality of the
external conditions. For example, barometric air pressure and even the LambdaConstant System
length of the flue gas tract can influence the attainable output. Here too, In developing the LambdaConstant System, we simply apply a researched
the LambdaConstant System ensures that the gas unit adjusts itself, conclusion: for every group of gas type, it is possible to represent the
thereby guaranteeing a regulated, environmentally responsible and dependency of temperature on air mass flow with a fixed Lambda value
efficient combustion from the very start. in a diagram. This, precisely, is the basis of the LambdaConstant System.
With temperature and air mass measurements, the intelligent control
system electronics can detect whether the system has reached its
optimum level of efficiency, and adjust to it as necessary.

An example: 24 kW power is demanded by the


800 heater control system. This necessitates an air
700 mass flow of 8 g/s and thus an optimal combustion
600 = constant temperature of 300 C.
The LambdaConstant System adjusts the gas/air
500
Temperature [C]

mixture until the optimum temperature has been


400
achieved.
300
200
100
0
Easy to recognize by the characteristic laminar inlet:
0 2 4 6 8 10 12
the LambdaConstant gas blower by ebm-papst.
Mass flow [g/s]

2 3

Das könnte Ihnen auch gefallen