Sie sind auf Seite 1von 37

Move Smart Move India

Mendatry Lifts Move by Govt Smart India


Indian Railways Faciliates with Lifts&Exclators.
All Airports with Lifts ,Exclators and Walkaways
Smart Buildings Lifts ,Exclators and Walkaways Lifts
,Exclators and Walkaways
Road & Bridges Lifts ,Exclators and Walkaways
Hospital ,Hotels,School,ShoppingComplex Lifts
,Exclators and Walkaways
Carparking Managements
Material Lifting
Sea Ports Lifts ,Exclators and Walkaways
Tunnel and Elevated Bridges Lifts ,Exclators and
Walkaways
Make In India become World Leader
National Manufacturing Policy (NMP):

NMP Objectives: NMP proposes setting up of National


Investment and Manufacturing Zones
Promote investments in the
(NIMZs) which are located in areas with
manufacturing sector
contiguous land of 5,000 hectares.
Make India a hub for both domestic and
international markets NIMZs would be a combination of
Increase the share of manufacturing in production units, public utilities, logistics,
GDP to 25% by 2022 environmental protection mechanism,
To enhance global competitiveness of residential areas and administrative
Indias manufacturing sector services.
Faciliate your Life and Lift
Calculate your Lift with Bussiness
Dream India Grow Building
Eligant Living Style in Process
Efficient Way
Safety Must
Sikhana to Padega Hi Follow NBC2016
Corporate Presentation Merging with Technologies
Smart and Safe Lift India National Mission Make in India Project (2017)
External/Internal Surge Source
Equipotential bonding for lightning protection according IEC 61024-
1 and IEC 61312-1; IEC62305

The 100% of lightning energy breaks down as


follows:

a) 50% of the lightning current will flow through


the ground
b) 50% of the lightning current will flow over the
connected metal parts out of the building:
In India & Sri Lanka Only Chance is Power Line
about 10% to the water pipe (metal)
Approximately 50 % of Total Lightning Current has
to
about 10% to the
be diverted gas pipe
to Power (metal)
lines
about 10% to the oil pipe (metal tank)
50 %
about 10% to the sewage pipe
a out % to the power suppliers i o i g feed
max. 5% or 5 kA shared across all data lines
50 %
Earthing Design and Require Result
For substation Large Power below 1.00Ohm
For substation Small Power below 2.00Ohm
SCADA/TELECOM and AutomationFor substation Large
Power below 0.50Ohm
Tower and Other Structure between 8-15Ohm
Lightning Surge Protection 50KA below 5Ohm or 100KA
between 8-15Ohm
Follow Standard IEC /IEEE
Recommended use of Hybrid Metal to Protect from Theft
Copper Clad Steel/Alumineum Clad Copper
Exothermeic weld IEEE 837
Surge in Systems and Result
Surge in DC Application
Surge Protection use Recommendation
v
JMV LPS Products
Copper Cladded Conductor For Electrical
Installation

The Copper Clad Steel Grounding Conductor is made up of steel with the coating of 99.99% pure copper. These
conductors/ wires
or strands are equipped with the strength of steel with the conductivity and copper with the better corrosion
resistance property. The concentric copper cladding is metallurgic ally bonded to a steel core through a continuous,
solid cladding process using pressure rolling for primary bonding. The copper cladding
thickness remains constant surrounding steel. We use different steel grades for the steel core result in Dead Soft
Annealed, High strength and Extra High Strength Characteristics.
The Copper Clad Steel Wire yields a composite conductivity of 21%, 30% and 40% IACS, and available in Annealed
and Hard drawn. We are delivering products with varied conductivity and tensile strength as per the customer need.
Further, the wire can be processed to be silver plated or tinned copper clad steel wire.
Most Efficient JointProcess

It is efficient and superior to all existing surface to-surface


mechanical retention connectors.
What is Exothermic Welding System?
Copper to Bi-Metal and Alumenium
Types of Exothermic Joints:

Possible to join any bi metal except aluminum


Exothermic welding is a process of making maintain free highly molecular bonding process is superior in
performance connection to any known mechanical or compression-type surface-to-surface contact connector.
Exothermic weld connections provide current carrying (fusing) capacity equal to that of the conductor and will
not deteriorate with age.
It offers Electrical connections between two or more copper to copper and copper to steel conductors.
Highly portable method as it does not require any external power source or heat source, so it can be done
almost anywhere.
It provides strong permanent molecular bond among metallic conductors that cannot loosen and further will
not deteriorate with age.
Connection does not corrode with time and it offers permanent conductivity.
Copper Clad Steel Solid ROD and Conductor
Thimble

Joint all phase wire/ cable with the help of


crimping tools and lugs

Step 1
Separation Sheet

Fixed the separation sheet between all wires/


cables

Gel / Silicon
Step 2
Close the filled Silicon enclosure from top and
bottom , complete installation is done.

Step 3
Features :
Provides cable with cable connections and jointing wires in switchboard / electric boxes Being a jelly it can be
easily fit into molds of any shape and size.
Helps in safeguarding electrical connections and also protects electrical connection joints from catching fire, sparking
and leakage current.
Eradicates all the possibilities of fire, electric shocks and sparks, etc. causes due to improper electrical connection
joints and safeguards structure, equipment and person.
Offers safety to your electrical joints from ageing, corrosion, moisture and also observes leakage current.
Advantages :
Nontoxic
Insulating
Highly reliable operation
Maintenance Free
Repairable
Cost Effective
High repeat value
Elasticity
Shape retention
JMVs Clients
Neeraj Saini 9910398538
Rahul Verma 9910398535
Manav Chandra - 9910398999
manav@jmv.co.in

Das könnte Ihnen auch gefallen