Sie sind auf Seite 1von 8

Heat Pump Product Range

Heat Pump Compact Units


and
Heat Pump Central Units

+ SAFE
+ COMFORTABLE
+ HIGHLY EFFICIENT
Copyright 2012 by WATERKOTTE GmbH Subject to alterations and errata! Fotos: WATERKOTTE, Fotolia

Together with skilled WATERKOTTE installation partners near you, we offer


benefits based on the longest experience in this field.

www.waterkotte.de
Description / model Dimensions (W x H x D in mm) Heat source / performance range

Ai1 QE + Heat source:


ground or ground water
Heat pump + Heat use: water
central unit
+ Up to 17,0 kW
All in One + Performance factor (COP)
up to 6,6 2)
Heat source: (depending on design size)
ground
+ Heated area:
up to 480 m2
Refrigerant R410A (36 W/m2)
701x1890x733

WPQLN + Heat source: air


+ Heat use: water
Heat source:
air + Up to 14 kW
+ Performance factor (COP)
Refrigerant R410A up to 3,6 1)
695 x 700 x 280 (indoor module) (controlled operation)

Ai1 QL 3) + Heat source: air


+ Heat use: water
Heat pump
central unit + Up to 14 kW
+ Performance factor (COP)
up to 3,6 1)
All in One (controlled operation)
Heat source:
air + Heated area:
up to 385 m2
Refrigerant R410A (36 W/m2)

943x1360x330 (outdoor module)

WPQL K + Heat source: air


+ Heat use: water
Heat pump
central unit + Up to 56 kW

2 up to 4 outdoor + Heated area:


modules up to 1555 m2
(36 W/m2)
Heat source:
air

Refrigerant R410A 700x1300x500 (indoor module)

1)
A2/W35, per EN 14511; 2) Tolerances stated in EN 12900 and EN 14511; 3) ehpa quality label
2/8
Properties Optional accessories

Heating system, ready for connection to electric, Automation:


hydraulic and control system + Room temperature sensor (pilot room)
a. Integrated indirect domestic water heating + Swimming pool upgrade kit
with charge pump + Mixing board
b. Domestic hot water tank 250 l, enamelled + COP counter
+ Electric resistance heating 6 kW + WEB interface
+ Compressor: Scroll technology
+ Economical natural cooling in the summer Others:
+ Underfloor heating, NTV convectors
+ Electronic starting current damping
+ Heat source accessories
+ Accessory kits: System combination (natural cooling), system
separation (without cooling)

Heating system, ready for connection to electric, Automation:


hydraulic and control system + Room temperature sensor (pilot room), heat meter, WEB interface
+ as Ai2 QL, however without domestic water heating
Others:
+ Underfloor heating, NTV convectors, connection accessories
+ Air guide and wind deflector screen

Heating system, ready for connection to electric, Automation:


hydraulic and control system + Room temperature sensor (pilot room)
a. Integrated indirect domestic water heating + Swimming pool upgrade kit
with charge pump + Mixing board
b. Domestic hot water tank 250 l, enamelled + Heat meter
c. Variant: Ai2 QL - without tank, for connection to provided + WEB interface
tank
+ Split design Others:
+ Outdoor / indoor module: + Underfloor heating, NTV convectors
refrigeration connection on site, for setting up apart + Connection accessories
+ Compressor drive with highly efficient EC motor, + Accessory kits: heating, domestic water
electronically commutated + Air guide and wind deflector screen
+ Electric resistance heating 6 kW
+ Economical natural cooling in the summer

Heating system, ready for connection to electric, Automation:


hydraulic and control system + Heat meter
+ With integrated system technology for heat recovery + WEB interface
+ Split design: Outdoor / indoor module; refrigeration connection
on site, for setting up apart Others:
+ Compressor drive with highly efficient EC motor, electronically + Underfloor heating, NTV convectors
commutated + Connection accessories
+ Electric resistance heating 6 kW + Accessory kits: heating, domestic water
+ Heating and cooling + Air guide and wind deflector screen
+ Air separator, air diverter, filling pressure gauge and
overpressure valve integrated. Pressure expansion vessel
(provided by the customer).

3/8
Description / model Dimensions (W x H x D in mm) Heat source / performance range

DS 5027 Ai 3) + Heat source:


ground or ground water
Heat pump + Heat use: water
central unit
+ Up to 26 kW
Heat source: + Performance factor (COP)
ground up to 7,0 2)
(depending on design size)
Refrigerant R410A
or R134a + 8 sizes;
Heated area:
up to 750 m2
(36 W/m2)

700x1300x500

DS 5027Ai NC + as DS 5027Ai + as DS 5027Ai


with natural cooling

Refrigerant R410A

DS 5027Ai RC + as DS 5027Ai + as DS 5027Ai


with climate cooling

Refrigerant R410A

DS 5050T + Heat source:


ground or ground water
Heat pump + Heat use: water
compact unit
with tandem + Up to 50 kW
compressors + Performance factor (COP)
up to 6,0 2)
Heat source: (depending on design size)
ground
+ Heated area:
Refrigerant R407C up to 1.389 m2
or R134a (36 W/m2)

754x1300x500

2)
Tolerances stated in EN 12900 and EN 14511; 3) quality label
4/8
Properties Optional accessories

Heating system, ready for connection to electric, Automation:


hydraulic and control system + Room temperature sensor (pilot room)
+ With integrated system technology for heat recovery + Swimming pool upgrade kit
+ Electric resistance heating 6 kW + Mixing board
+ Compressor: Scroll technology + COP counter
+ WEB interface

Others:
+ Connection accessories
+ Underfloor heating, NTV convectors
+ Electronic starting current damping

+ As DS 5027Ai, additional provided with economical natural + as DS 5027 Ai


cooling in the summer.

+ As DS 5027Ai, additional provided with system components + as DS 5027 Ai


for active cooling.

Heat pump compact unit Automation:


+ Power regulation: 50 % / 100 % + Room temperature sensor (pilot room)
+ Compressor: Tandem scroll + Swimming pool upgrade kit
+ Electronic starting current damping + Mixing board
+ Removable metal cladding, + COP counter
without separation of pipe connections + WEB interface
+ Insulation of structure-born noise
via double chassis construction Others:
+ Heat source technology, hot water production
+ Underfloor heating, NTV convectors

5/8
Description / model Dimensions (W x H x D in mm) Heat source / performance range

DS 5110T + Heat source:


ground or ground water
Heat pump + Heat use: water
compact unit
+ Up to 112 kW
Heat source: + Performance factor up to 5,9 2)
ground (depending on design size)

Refrigerant R410A + Heated area:


or R134a up to 3000 m2
(36 W/m2)
1100x1300x850

DS 5240 + Heat source:


ground or ground water
+ Heat use: water
Heat pump
compact unit
+ Up to 230 kW
+ Performance factor up to 5,5 2)
Heat source: (depending on design size)
ground

Refrigerant R407C + Heated area:


or R134a up to 6.389 m2
(36 W/m2)

1400x1565x850

DS 6500 + Heat source:


ground or ground water
+ Heat use: water
Heat pump
compact unit
+ Up to 491 kW
+ Performance factor up to 5,8 2)
Heat source:
(depending on design size)
ground

Refrigerant R407C + Heated area:


or R134a up to 13.639 m2
(36 W/m2)

2300x1827x930

2)
Tolerances stated in EN 12900 and EN 14511

6/8
Properties Optional accessories

Heat pump compact unit Automation:


+ Soundproofed housing, ready-to-connect + Partial-load control
+ Removable metal cladding, + COP counter
without separation of pipe connections + WEB interface
+ Insulation of structure-born noise
via double chassis construction Others:
+ Compressor: Tandem scroll, power regulation + Heat source technology, hot water production
50 % / 100 % + Underfloor heating, NTV convectors
+ Electronic starting current damping

Heat pump compact unit Automation:


+ Soundproofed housing, ready-to-connect + Partial-load control
+ Compressor: Reciprocating piston compressor, + COP counter (power regulation 100 %)
power regulation: 75 % / 100 % or 66 % / 100 % + WEB interface
+ Removable metal cladding,
without separation of pipe connections Others:
+ Insulation of structure-born noise + Heat source technology, hot water production
via double chassis construction + Underfloor heating, NTV convectors
+ Electronic starting current damping

Heat pump compact unit Automation:


+ Open construction, ready-to-connect, + Partial-load control
with all-round protective frames + COP counter (power regulation 100 %)
+ Semi-hermetic screw compressor + WEB interface
+ Power regulation 75 / 100 %
Others:
+ Heat source technology, hot water production
+ Underfloor heating, NTV convectors

7/8
WATERKOTTE GmbH
Gewerkenstrae 15, D-44628 Herne
Tel.: +49 (0) 23 23 / 93 76 - 0, Fax: +49 (0) 23 23 / 93 76 - 99,
Service: +49 (0) 23 23 / 93 76 - 350
E-Mail: info@waterkotte.de, Internet: www.waterkotte.de

EuroTherm AG

WATERKOTTE Austria GmbH WATERKOTTE Nederland EuroTherm AG


Leisbach 32 WATERKOTTE Warmtepompen BV Industriestrae 54
A-9074 Keutschach Postadres: Hoekstraat 7a CH-1791 Courtaman
Tl.: +43 (0) 463 29403 0 5447 PA Rijkevoort (NL) Tl.: +41 (0) 26 6848181
Fax: +43 (0) 463 29403 018 Tl.: +31 (0) 485-325573 Fax: +41 (0) 26 6848189
wouk@waterkotte.at Fax: +31 (0) 485-372337 info@eurothermag.ch
www.waterkotte.at info@waterkotte.nl www.waterkotte-eurotherm.ch
www.waterkotte.nl

Nutherm Limited Mondial Gothermie Sarl Hennlich Industrietechnik spol.s.r.o.


Sallybrook, Manorcunningham ZAC de la Bruyre Ceskolipsk 9
Letterkenny 18 bis rue de la Bruyre CZ-41201 Litomerice
Co Donegal, Ireland F-31120 Pinsaguel Tl.: +42 (0) 416 711 250
Tl.: +353 (0) 74 91 57893 Tl.: +33 (0) 5 34 57 21 90 Fax: +42 (0) 416 711 299
Fax: +353 (0) 74 91 57856 Fax: +33 (0) 5 34 57 14 67 sumera@hennlich.cz
UK Office mondialgeothermie@wanadoo.fr www.hennlich.cz
SATRA Innovation Park www.mondialgeothermie.fr
Rockingham Road
Kettering, Northants, NN16 9JH, UK
Tl. +44 (0) 1536 533280
info@nutherm.eu
www.nutherm.eu

Your local WATERKOTTE system partner:


check the validity of this label at www.ehpa.org/QL

16112012 /2500 Z17509

European Quality Label


for Heat Pumps

Copyright 2012 by WATERKOTTE GmbH, Herne Subject to alterations and errata!


8/8

Das könnte Ihnen auch gefallen