1 Input data
Anchor type and diameter: HIT-HY 200-R + HIT-V (8.8) M20
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,opti = 240 mm (hef,limit = 400 mm)
Material: 8.8
Evaluation Service Report: ETA 12/0084
Issued I Valid: 2/3/2017 | -
Proof: Engineering judgement SOFA BOND - based on ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 25 mm
Anchor plate: lx x ly x t = 420 mm x 420 mm x 25 mm; (Recommended plate thickness: not calculated
Profile: Flat bar; (L x W x T) = 403 mm x 403 mm x 0 mm
Base material: cracked concrete, C25/30, fc,cube = 30.00 N/mm2; h = 3000 mm, Temp. short/long: 30/40 C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: German Steel Cont L.L.C Page: 2
Specifier: Dhinakaran Project: Mirdif CC Cineam
Address: Sub-Project I Pos. No.: Crane Base Support
Phone I Fax: 0564301278 | Date: 6/21/2017
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads

Anchor reactions [kN] 1 2 3


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.000 13.754 7.417 11.583
2 0.000 13.754 7.417 11.583 4 5 6
3 0.000 13.754 7.417 11.583
x
4 0.000 13.754 7.417 11.583 Compression
5 0.000 13.754 7.417 11.583 7 8 9
6 0.000 13.754 7.417 11.583
7 0.000 13.754 7.417 11.583
8 0.000 13.754 7.417 11.583
9 0.000 13.754 7.417 11.583 10 11 12
10 0.000 13.754 7.417 11.583
11 0.000 13.754 7.417 11.583
12 0.000 13.754 7.417 11.583
max. concrete compressive strain: 0.09 []
max. concrete compressive stress: 2.58 [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(0/0): 456.000 [kN]

3 Tension load (EOTA TR 029, Section 5.2.2)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* N/A N/A N/A N/A
Combined pullout-concrete cone failure** N/A N/A N/A N/A
Concrete Breakout Strength** N/A N/A N/A N/A
Splitting failure** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: German Steel Cont L.L.C Page: 3
Specifier: Dhinakaran Project: Mirdif CC Cineam
Address: Sub-Project I Pos. No.: Crane Base Support
Phone I Fax: 0564301278 | Date: 6/21/2017
E-Mail:

4 Shear load (EOTA TR 029, Section 5.2.3)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 13.754 78.400 18 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 165.052 150.524 110 not recommended
Concrete edge failure in direction y+** 140.770 29.691 475 not recommended
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
98.000 1.250 78.400 13.754

4.2 Pryout Strength (Concrete Breakout Strength controls)


Ac,N [mm2] A0c,N [mm2] ccr,N [mm] scr,N [mm] k-factor
350000 160000 360 720 2.000
h'ef [mm] c'cr,N [mm] s'cr,N [mm]
133 200 400
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 0.850 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
60.716 1.500 150.524 165.052

4.3 Concrete edge failure in direction y+


lf [mm] dnom [mm] k1 a b
240 20.0 1.700 0.155 0.072
c1 [mm] Ac,V [mm2] A0c,V [mm2]
100 90000 45000
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V
1.000 1.000 1.011 0 1.000 1.000
V0Rk,c [kN] gM,c VRd,c [kN] VSd [kN]
22.033 1.500 29.691 140.770

5 Displacements (highest loaded anchor)


Short term loading:
NSk = 0.000 [kN] dN = 0.000 [mm]
VSk = 34.758 [kN] dV = 1.390 [mm]
dNV = 1.390 [mm]
Long term loading:
NSk = 0.000 [kN] dN = 0.000 [mm]
VSk = 34.758 [kN] dV = 2.085 [mm]
dNV = 2.085 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: German Steel Cont L.L.C Page: 4
Specifier: Dhinakaran Project: Mirdif CC Cineam
Address: Sub-Project I Pos. No.: Crane Base Support
Phone I Fax: 0564301278 | Date: 6/21/2017
E-Mail:

6 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
Characteristic bond resistances depend on short- and long-term temperatures.
Please contact Hilti to check feasibility of HIT-V rod supply.
The design method SOFA assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling
the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
The compliance with current standards (e.g. EC3) is the responsibility of the user
An SLS-check is not performed for SOFA and has to be provided by the user!

Fastening does not meet the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: German Steel Cont L.L.C Page: 5
Specifier: Dhinakaran Project: Mirdif CC Cineam
Address: Sub-Project I Pos. No.: Crane Base Support
Phone I Fax: 0564301278 | Date: 6/21/2017
E-Mail:

7 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-HY 200-R + HIT-V (8.8) M20
Profile: Flat bar; 403 x 403 x 0 mm Installation torque: 0.150 kNm
Hole diameter in the fixture: df = 22 mm Hole diameter in the base material: 22 mm
Plate thickness (input): 25 mm Hole depth in the base material: 240 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 284 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to instructions for use is required

7.1 Recommended accessories

Drilling Cleaning Setting


Suitable Rotary Hammer Compressed air with required Dispenser including cassette and mixer
Properly sized drill bit accessories to blow from the bottom of Seismic/Filling set
the hole Torque wrench
Proper diameter wire brush
y

210 210

60
1 2 3

210
100

4 5 6
100

7 8 9
100

210

10 11 12
60

60 150 150 60

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -150 150 200 500 400 100 7 -150 -50 200 500 200 300
2 0 150 350 350 400 100 8 0 -50 350 350 200 300
3 150 150 500 200 400 100 9 150 -50 500 200 200 300
4 -150 50 200 500 300 200 10 -150 -150 200 500 100 400
5 0 50 350 350 300 200 11 0 -150 350 350 100 400
6 150 50 500 200 300 200 12 150 -150 500 200 100 400

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: German Steel Cont L.L.C Page: 6
Specifier: Dhinakaran Project: Mirdif CC Cineam
Address: Sub-Project I Pos. No.: Crane Base Support
Phone I Fax: 0564301278 | Date: 6/21/2017
E-Mail:

8 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Das könnte Ihnen auch gefallen