Sie sind auf Seite 1von 193

ARTESIA MID RISE BUILDING (G+28) ON PLOT

NO. 676-5408(E006)

ITEM
STRUCTURAL ANALYSIS FOR CANOPY STRUCTURE AT
TOWER A - 24 TH LEVEL.

Document Number
783-RUMG-ST- CALC-026
783-RUMG-ST- CALC-005

Revision 0

1 of 341
STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level
STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

INDEX
1 BASIC DATA 1

2 INTRODUCTION 3

3 LOAD COMBINATIONS 4

4 INPUTS & LOAD CALCULATIONS

5 ANALYSIS & DESIGN RESULTS 191

6 CONNECTION DESIGN

7. ENGINEERING DRAWINGS

8. REFERENCES 204
STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

1. Basic Data
1.1 Standards

Following are the main codes & specifications which are considered to complete the analysis and design exercise.
BS 5950-Part 1:2000 - Structural use of steelwork in building
BS 6399-Part 2: 1997: Wind load
BS EN 1991-1-4:2005
Basis of design report
1.2 Materials Data

a) SteelProperties


Young's modulus = 2.05E+08 kN/m2

Poissons ratio = 0.3

Density = 7850 kg/m3


b) Structural Steel Shapes : S275 JR
c) Structural Steel Plates : S275 JR EN 10025 : 2004
d) Bolts, Nuts & Washers : Gr. 8.8
e) Welding Electrodes : E7018
f) Concrete Grade : M40

1.3. Performance Criteria

The probabilistic approach for both structural properties and loading conditions i.e. ultimate limit states design
philosophy has been used here.

For checking of deflections, Serviceability Limit states has been used.

Reference: BS5950: Part 1 table 8

Horizontal deflection of columns = L/300

Vertical deflection of cantilever beams = L/180

Vertical deflection both end supported beams = L/240

1.4. Programs Used:

- STAAD.Pro V8i
- Hilti Prefixing Anchor
- Limcon
- Robot
- Windows 7 Professional Microsoft Office
STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

2. Introduction& Load Analysis

2.1 Introduction

The following report emphasis on the structural calculation of steel canopy at 27thlevel for the project
ARTESIA MIDRISE BUILDING G+28ON PLOT 676-5408.

This document covers the analysis and design of structural steel work for below defined loads & load combination
and the connections are design as bolted & welded connections.

Dead Load (D.L)

The dead loads & lateral loads are considered in the analysis complying with the clients specifications as follows:

i. Self weight of steel members and connections. = 1.1 times


ii. ACP Cladding Load = 2.0 kN/m2

Superimposed Dead Load (D.L)

i. Superimposed Dead Load Considered = 0.6 kN/m2

Live Load (L.L)

i. Roof live load as per BS6399 = 0.75 kN/m2

Wind Loading

A detailed wind load calculation as per BS 6399-Part 2: 1997- Loadings for buildings. Code of practice
for wind loads. Based on 3s gust wind speed of 45 m/s as per municipality requirements have been carried out for Tower A.
Also the wind pressure/ suction for different zones have been tabulated.

a) BS 6399-Part 2: 1997: Wind load

b) BS EN 1991-1-4:2005

Seismic Loading

A detailed seismic load calculation as per UBC1997- Earthquake Design

Temperature Loading

The Temperature varience is considered as +/- 32 degrees Celsius


STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

3. Loads and Loading Combinations

a) Serviceability Load Cases

AS PER BS5950 PART-1:2000 & CLAUSE 2.5 & UBC

1 DL+LL

2 DL+SL+LL

3 DL+WL

4 DL+0.8LL+0.8WL

5 0.9DL+1.0EQ LOAD

6 DL+LL+TL

b) Factored/ Ultimate Load Combinations

AS PER BS5950 PART-1:2000, TABLE-2 PAGE NO:12 & UBC

1 1.4DL+1.6LL

2 1.4DL+1.4SL+1.6LL

3 1.4DL+1.4WL

4 DL+1.4WL

5 1.2DL+1.2LL+1.2WL

6 1.2DL+0.5LL+1.0EQ















STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

4.0 INPUTS & LOAD COMBINATIONS


Sheet

Job No
PROJECT ARTESIA MID RISE BUILDING (G+28) ON PLOT NO.676-5408(E006)
Date 6/18/2017
SUBJECT WIND LOAD Reference BS5399
Wind load Calculation
Wind load is calculated as per BS 6399-Part 2 code of practice for wind loads
Building type Factor Kb = 1 (Ref: Table 1)
Maximum Height of the structure ~ 100 m
Dynamic augmentation factor < 0.1 (Ref:Fig 3)
Building is not dynamic,BS6399-part2 is applicable for this structure and Standard method
is used to calculate wind pressure

Basic wind speed = 45 m/sec


(3-Sec gust wind speed 10m above ground level)
Equivalent hourly mean speed @ open level ground
Appropriate to the geographical conditions Vb = 30 m/sec
Pages from Dubai Wind code is attached for reference
Altitude factor Sa = 1 (Ref: Cl 2.2.2.2)
Direction factor Sd = 1 (Ref: Cl 2.2.2.3)
Seasonal factor Ss = 1 (Ref: Cl 2.2.2.4)
Probability factor Sd = 1 (Ref: Cl 2.2.2.5)
Hence
Site Wind speed Vs = Vb*Sa*Sd*Ss (Ref: Cl 2.2.2)
Site wind Speed Vs = 30 m/sec
Effective height of the structure He = 100 m
Closest distance to sea = 10 kM
Terrain and building factor Sb = 2.12 (Ref: Table 4)

Effective wind Speed Ve = Vs*Sb


= 30*2.12
= 63.6 m/sec
Dynamic wind pressure q = 0.613Ve2 (Ref: Cl 2.1.2)
= 0.613*63.6^2/1000
2
= 2.5 kN/m

9 of 341
Sheet

Job No
PROJECT ARTESIA MID RISE BUILDING (G+28) ON PLOT NO.676-5408(E006)
Date 6/18/2017
SUBJECT WIND LOAD Reference BS5399
Wind load Calculation
(i) For Wall (x-DIRECTION):

Depth of building = 13 m
Height = 2.5 m
(D/H) = 5.2 >4

Internal pressure coffecient Cpi = 0.2


Internal suction coffecient Cpi = -0.3

-0.1 -0.1

E E
-0.8 -0.8 -0.8
B B1 B B1
0.2 A -0.3
-1.3 A -1.3 -1.3

D D

06
0.6
Wind Direction Pressure 0.6
Wind Direction Suction

Pressure:
Windward Side = (0.6-0.2)*2.5 = 1.00 kN/m2
Leeward Side = (-0.1-0.2)*2.5) = 0.75 kN/m2
ZONE A = (-1.3-0.2)*2.5) = 3.75 kN/m2
ZONE B = (-0.8-0.2)*2.5) = 2.50 kN/m2

Suction:
Windward Side = (0.6--0.3)*2.5) = 2.25 kN/m2
Leeward Side = (-0.1--0.3)*2.5) = 0.50 kN/m2
ZONE A = (-1.3--0.3)*2.5) = 2.50 kN/m2
ZONE B = (-0.8--0.3)*2.5) = 1.25 kN/m2

10 of 341
Sheet

Job No
PROJECT ARTESIA MID RISE BUILDING (G+28) ON PLOT NO.676-5408(E006)
Date 6/18/2017
SUBJECT WIND LOAD Reference BS5399
Wind load Calculation
(i) For Wall (Z-DIRECTION):

Depth of building = 5.01 m


Height = 2.5 m
(D/H) = 2.004 <4

Internal pressure coffecient Cpi = 0.2


Internal suction coffecient Cpi = -0.3

-0.23 -0.23

E E
-0.8 -0.8 -0.8
B B1 B B1
-1.3 0.2 -0.3
A -1.3 -1.3
A
D D

0 73
0.73
Wind Direction Pressure 0.73
Wind Direction Suction

Pressure:
Windward Side = (0.73-0.2)*2.5 = 1.33 kN/m2
Leeward Side = (-0.23-0.2)*2.5) = 1.08 kN/m2
ZONE A = (-1.3-0.2)*2.5) = 3.75 kN/m2
ZONE B = (-0.8-0.2)*2.5) = 2.50 kN/m2

Suction:
Windward Side = (0.73--0.3)*2.5) = 2.58 kN/m2
Leeward Side = (-0.23--0.3)*2.5) = 0.17 kN/m2
ZONE A = (-1.3--0.3)*2.5) = 2.50 kN/m2
ZONE B = (-0.8--0.3)*2.5) = 1.25 kN/m2

(I) For Roof X-DIRECTION

11 of 341
Sheet

Job No
PROJECT ARTESIA MID RISE BUILDING (G+28) ON PLOT NO.676-5408(E006)
Date 6/18/2017
SUBJECT WIND LOAD Reference BS5399
Wind load Calculation
B= 21.68 m A= -2.00
A= b/4 = 5.42 m (B/4) B= -1.40
LENGTH = 2.168 m (B/10) C= -0.70
D= -0.20
UPWARD (Pressure):
ZONE - A = (-2-0.2)*2.5 = 5.50 kN/m2
ZONE - B = (-1.4-0.2)*2.5 = 4.00 kN/m2 COEFFICIENT = +0.2
ZONE - C = (-0.7-0.2)*2.5 = 2.25 kN/m2 Note: By considering the louvers in between the
ZONE - D = (-0.2-0.2)*2.5 = 1.00 kN/m2 column bay, the wind load upward/downward is
DOWNWARD (Suction): applied as 50% open wind & 100% wind
considered only in ACP cladding location.
FOR DOWNWARD, THE ZONE-D IS CONSERVATIVELY
COEFFICIENT = 0.3
CONSIDERED FOR THE WHOLE AREA.
ZONE - D = (-0.2-(0.3))*2.5 = 1.25 kN/m2

(I) For Roof Z-DIRECTION

B= 5.01 m A= -2.00
A= b/4 = 1.2525 m (B/4) B= -1.40
LENGTH = 0.501 m (B/10) C= -0.70
D= -0.20
0 20
UPWARD [PRESSURE]:
ZONE - A = (-2-0.2)*2.5 = 5.50 kN/m2
ZONE - B = (-1.4-0.2)*2.5 = 4.00 kN/m2 COEFFICIENT = +0.2
ZONE - C = (-0.7-0.2)*2.5 = 2.25 kN/m2 Note: By considering the louvers in between the
ZONE - D = (-0.2-0.2)*2.5 = 1.00 kN/m2 column bay, the wind load upward/downward is
DOWNWARD [SUCTION]: applied as 50% open wind & 100% wind
considered only in ACP cladding location.
FOR DOWNWARD, THE ZONE-D IS CONSERVATIVELY
COEFFICIENT =0.3
CONSIDERED FOR THE WHOLE AREA.
ZONE - C = (-0.2-(0.3))*2.5 = 1.25 kN/m2

12 of 341
_ >f/>?"#!

 6  ;
   ((    
  
 

      ; <+=4--9

*     # &+
*       # .J&
WX   <+=4--9 483>*
*    > ; T >; # 4J..

WX   <+=4--9 483C*
*  

          
X   # QJ,
X   # QJ,
WX   <+=4--9 483$*
* ; ; # 
((
# Q
WX   <+=4--9 483*
*    
 ; # (
=     
 4, B
$ 
   $ # 4J..
$ # 4J..
WX   <+=4--9 483 483*
* $
  3    = # .J.',
WX   <+=4--9 
 48'.J&J4*
      ((  ;
    6  48'.J&J4 <+=4--9  J
 6 ;  
 W?
 '.3,3<+=4--9*   J
+    # =]>])%WX]*
>   6   
     
?
 '.3,       H 
 # &J,=]>])%X
?
 '.383        
 # .J44=]>])
>    ;
    
  6 ;;  6 J

13 of 341
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Materials
Mat Name E Density
(kN/mm2) (kg/m3) (1/K)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
2 UB254X102X22 28.000 119.000 2.84E+3 4.145 STEEL
3 PIP35512.5 135.000 19.8E+3 19.8E+3 39.7E+3 STEEL
5 UB533X210X101 129.000 2.69E+3 61.5E+3 100.953 STEEL
6 UB356X171X51 64.900 968.000 14.1E+3 23.811 STEEL
7 UB533X210X122 155.000 3.39E+3 76E+3 178.377 STEEL
8 UB356X127X39 49.800 358.000 10.2E+3 15.097 STEEL

Basic Load Cases


Number Name

1 EQ +X
2 EQ +Z
3 DEAD LOAD
4 SDL
5 LIVE LOAD
6 WL +X PRESSURE
7 WL -X SUCTION
8 WL +Z PRESSURE
9 WL -Z SUCTION
10 TEMP +VE
11 TEMP -VE

Print Time/Date: 29/06/2017 13:55 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 3
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

101 DD+LL 3 DEAD LOAD 1.00


5 LIVE LOAD 1.00
102 DD+SL+LL 3 DEAD LOAD 1.00
4 SDL 1.00
5 LIVE LOAD 1.00
103 DL+WL 3 DEAD LOAD 1.00
6 WL +X PRESSURE 1.00
104 DL+WL 3 DEAD LOAD 1.00
7 WL -X SUCTION 1.00
105 DL+WL 3 DEAD LOAD 1.00
8 WL +Z PRESSURE 1.00
106 DL+WL 3 DEAD LOAD 1.00
9 WL -Z SUCTION 1.00
107 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
6 WL +X PRESSURE 0.80
108 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
7 WL -X SUCTION 0.80
109 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
8 WL +Z PRESSURE 0.80
110 DL+0.8LL+0.WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
9 WL -Z SUCTION 0.80
111 0.9DL+1.0EQ 3 DEAD LOAD 0.90
1 EQ +X 1.00
112 0.9DL+1.0EQ 3 DEAD LOAD 0.90
2 EQ +Z 1.00
113 DL+LL+TL 3 DEAD LOAD 1.00
5 LIVE LOAD 1.00
10 TEMP +VE 1.00
114 DL+LL+TL 3 DEAD LOAD 1.00
5 LIVE LOAD 1.00
11 TEMP -VE 1.00
201 1.4DL+1.6LL 3 DEAD LOAD 1.40
5 LIVE LOAD 1.60
202 1.4DD+1.4SL+1.6LL 3 DEAD LOAD 1.40
4 SDL 1.40
5 LIVE LOAD 1.60
203 1.4DL+1.4WL 3 DEAD LOAD 1.40
6 WL +X PRESSURE 1.40
204 1.4DL+1.4WL 3 DEAD LOAD 1.40
7 WL -X SUCTION 1.40
205 1.4DL+1.4WL 3 DEAD LOAD 1.40

Print Time/Date: 29/06/2017 13:55 STAAD.Pro for Windows 20.07.04.12 Print Run 2 of 3
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Combination Load Cases Cont...


Comb. Combination L/C Name Primary Primary L/C Name Factor

8 WL +Z PRESSURE 1.40
206 1.4DL+1.4WL 3 DEAD LOAD 1.40
9 WL -Z SUCTION 1.40
207 DL+1.4WL 3 DEAD LOAD 1.00
6 WL +X PRESSURE 1.40
208 DL+1.4WL 3 DEAD LOAD 1.00
7 WL -X SUCTION 1.40
209 DL+1.4WL 3 DEAD LOAD 1.00
8 WL +Z PRESSURE 1.40
210 DL+1.4WL 3 DEAD LOAD 1.00
9 WL -Z SUCTION 1.40
211 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
6 WL +X PRESSURE 1.20
212 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
7 WL -X SUCTION 1.20
213 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
8 WL +Z PRESSURE 1.20
214 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
9 WL -Z SUCTION 1.20
215 1.2DL+0.5LL+1.0EQ 3 DEAD LOAD 1.20
5 LIVE LOAD 0.50
1 EQ +X 1.00
216 1.2DL+0.5LL+1.0EQ 3 DEAD LOAD 1.20
5 LIVE LOAD 0.50
2 EQ +Z 1.00
217 1.2DL+1.2LL+1.2TL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
10 TEMP +VE 1.20
218 1.2DL+1.2LL+1.2TL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
11 TEMP -VE 1.20

Print Time/Date: 29/06/2017 13:55 STAAD.Pro for Windows 20.07.04.12 Print Run 3 of 3
STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

5.0 ANALYSIS & DESIGN RESULTS


Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Materials
Mat Name E Density
(kN/mm2) (kg/m3) (1/K)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
2 UB254X102X22 28.000 119.000 2.84E+3 4.145 STEEL
3 PIP35512.5 135.000 19.8E+3 19.8E+3 39.7E+3 STEEL
5 UB533X210X101 129.000 2.69E+3 61.5E+3 100.953 STEEL
6 UB356X171X51 64.900 968.000 14.1E+3 23.811 STEEL
7 UB533X210X122 155.000 3.39E+3 76E+3 178.377 STEEL
8 UB356X127X39 49.800 358.000 10.2E+3 15.097 STEEL

Basic Load Cases


Number Name

1 EQ +X
2 EQ +Z
3 DEAD LOAD
4 SDL
5 LIVE LOAD
6 WL +X PRESSURE
7 WL -X SUCTION
8 WL +Z PRESSURE
9 WL -Z SUCTION
10 TEMP +VE
11 TEMP -VE

Print Time/Date: 29/06/2017 13:55 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 3
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

101 DD+LL 3 DEAD LOAD 1.00


5 LIVE LOAD 1.00
102 DD+SL+LL 3 DEAD LOAD 1.00
4 SDL 1.00
5 LIVE LOAD 1.00
103 DL+WL 3 DEAD LOAD 1.00
6 WL +X PRESSURE 1.00
104 DL+WL 3 DEAD LOAD 1.00
7 WL -X SUCTION 1.00
105 DL+WL 3 DEAD LOAD 1.00
8 WL +Z PRESSURE 1.00
106 DL+WL 3 DEAD LOAD 1.00
9 WL -Z SUCTION 1.00
107 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
6 WL +X PRESSURE 0.80
108 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
7 WL -X SUCTION 0.80
109 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
8 WL +Z PRESSURE 0.80
110 DL+0.8LL+0.WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
9 WL -Z SUCTION 0.80
111 0.9DL+1.0EQ 3 DEAD LOAD 0.90
1 EQ +X 1.00
112 0.9DL+1.0EQ 3 DEAD LOAD 0.90
2 EQ +Z 1.00
113 DL+LL+TL 3 DEAD LOAD 1.00
5 LIVE LOAD 1.00
10 TEMP +VE 1.00
114 DL+LL+TL 3 DEAD LOAD 1.00
5 LIVE LOAD 1.00
11 TEMP -VE 1.00
201 1.4DL+1.6LL 3 DEAD LOAD 1.40
5 LIVE LOAD 1.60
202 1.4DD+1.4SL+1.6LL 3 DEAD LOAD 1.40
4 SDL 1.40
5 LIVE LOAD 1.60
203 1.4DL+1.4WL 3 DEAD LOAD 1.40
6 WL +X PRESSURE 1.40
204 1.4DL+1.4WL 3 DEAD LOAD 1.40
7 WL -X SUCTION 1.40
205 1.4DL+1.4WL 3 DEAD LOAD 1.40

Print Time/Date: 29/06/2017 13:55 STAAD.Pro for Windows 20.07.04.12 Print Run 2 of 3
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Combination Load Cases Cont...


Comb. Combination L/C Name Primary Primary L/C Name Factor

8 WL +Z PRESSURE 1.40
206 1.4DL+1.4WL 3 DEAD LOAD 1.40
9 WL -Z SUCTION 1.40
207 DL+1.4WL 3 DEAD LOAD 1.00
6 WL +X PRESSURE 1.40
208 DL+1.4WL 3 DEAD LOAD 1.00
7 WL -X SUCTION 1.40
209 DL+1.4WL 3 DEAD LOAD 1.00
8 WL +Z PRESSURE 1.40
210 DL+1.4WL 3 DEAD LOAD 1.00
9 WL -Z SUCTION 1.40
211 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
6 WL +X PRESSURE 1.20
212 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
7 WL -X SUCTION 1.20
213 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
8 WL +Z PRESSURE 1.20
214 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
9 WL -Z SUCTION 1.20
215 1.2DL+0.5LL+1.0EQ 3 DEAD LOAD 1.20
5 LIVE LOAD 0.50
1 EQ +X 1.00
216 1.2DL+0.5LL+1.0EQ 3 DEAD LOAD 1.20
5 LIVE LOAD 0.50
2 EQ +Z 1.00
217 1.2DL+1.2LL+1.2TL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
10 TEMP +VE 1.20
218 1.2DL+1.2LL+1.2TL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
11 TEMP -VE 1.20

Print Time/Date: 29/06/2017 13:55 STAAD.Pro for Windows 20.07.04.12 Print Run 3 of 3
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:44

3D STRUCTURAL VIEW

Y
X
Z

Load 101

Print Time/Date: 29/06/2017 13:45 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:46

PROFILES

Y
X
Z

Load 101

Print Time/Date: 29/06/2017 13:47 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:46

MEMBER RELEASE AND SPECIFICATIONS

Y
X
Z

Load 101

Print Time/Date: 29/06/2017 13:47 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:46

SUPPORT CONDITIONS

Y
X
Z

Load 101

Print Time/Date: 29/06/2017 13:47 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:46

MATERIAL

STEELSTEEL
STEELSTEELSTEELSTEEL
STEELSTEELSTEELSTEELSTEEL
STEEL
STEEL STEELSTEELSTEELSTEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEELSTEELSTEELSTEEL STEEL STEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEEL STEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEEL STEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEEL STEEL
STEEL
STEEL
STEELSTEELSTEELSTEELSTEEL STEEL STEEL STEEL
STEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEEL STEEL
STEEL STEEL
STEEL
STEEL
STEELSTEELSTEELSTEELSTEEL
STEEL STEEL
STEEL
STEEL
STEEL
STEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEEL STEEL STEEL
STEEL
STEELSTEELSTEELSTEELSTEEL
STEELSTEELSTEELSTEELSTEEL STEELSTEELSTEEL
STEELSTEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEELSTEELSTEEL
STEELSTEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEEL STEELSTEELSTEEL
STEELSTEELSTEELSTEELSTEEL STEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEELSTEELSTEEL
STEEL
STEEL
STEEL
STEEL STEELSTEELSTEELSTEEL STEELSTEELSTEEL
STEEL
STEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEEL
STEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEEL STEELSTEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEEL
STEEL
STEELSTEEL
STEELSTEELSTEELSTEELSTEEL
STEEL STEELSTEELSTEELSTEELSTEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEELSTEELSTEELSTEELSTEEL
STEELSTEELSTEELSTEELSTEELSTEEL STEELSTEELSTEELSTEELSTEEL
STEELSTEELSTEELSTEELSTEEL STEELSTEELSTEEL
STEELSTEEL
STEELSTEELSTEELSTEELSTEEL STEEL
STEEL STEELSTEEL
STEELSTEELSTEEL
STEELSTEELSTEELSTEEL
STEEL STEEL STEELSTEELSTEELSTEEL
STEELSTEELSTEELSTEEL STEEL
STEELSTEELSTEELSTEELSTEEL STEELSTEELSTEELSTEEL
STEEL STEEL
STEELSTEELSTEELSTEEL
STEEL
STEEL STEEL STEEL STEELSTEELSTEELSTEELSTEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL STEELSTEELSTEELSTEELSTEEL
STEEL STEEL
STEEL
STEEL STEEL STEELSTEELSTEELSTEELSTEEL
STEEL STEELSTEELSTEELSTEELSTEEL
STEEL STEEL
STEEL STEEL STEELSTEELSTEELSTEELSTEEL
STEEL
STEEL
STEEL STEEL STEEL STEELSTEELSTEELSTEELSTEEL
STEEL STEEL STEELSTEELSTEELSTEELSTEEL
STEEL
STEEL STEEL STEELSTEELSTEELSTEELSTEEL

Y STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEEL
STEELSTEELSTEELSTEEL
STEELSTEELSTEEL

X STEEL STEELSTEEL STEELSTEEL STEEL


STEEL
STEEL STEEL
STEEL STEELSTEEL STEELS TEELSTEEL
STEEL
STEEL STEEL
STEELSTEEL STEEL STEELSTEEL
STEEL STEEL STEEL
STEEL

Z
STEELS TEEL
STEEL
STEEL
STEELSTEEL
STEEL
STEEL

Load 3

Print Time/Date: 29/06/2017 13:48 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 1
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:46

APPLICATION OF LOADS AND LOAD COMBINATIONS

Y 1.Primary load 2.Serviceability load 3.Factored load


X case combination combination
Z

Load 3

Print Time/Date: 29/06/2017 13:47 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 1
DESIGN PARAMETERS
DEFLECTION

All deflections are within the limit of L/240 for main beams and L/180 for
cantilevers.
Additional pre cambers shall be provided on the cantilever ends.
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

PRECAMBER VALUE

Y:-1.452 mm

Y:-8.855 mm

Y X
Z Y:-40.121 mm Y:-5.616 mm
Y:-16.696 mm Y:-5.613 mm
Load 101 : Displacement
Displacement - mm

Pre-camber value

Print Time/Date: 29/06/2017 13:51 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 1
STRESS RATIO

<1 Hence safe


STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

6.0 CONNECTION DESIGN


BASE PLATE DETAILS
M30 GR8.8 J-BOLT

12mm PPBW
COLUMN WELD

EMBED DEPTH = 400mm


CHS355X12.5

Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max FX 82 218:1.2DL+1.2L 21.831 142.577 17.884 34.168 3.502 -51.053
Min FX 80 204:1.4DL+1.4W -11.805 150.096 9.968 16.936 -2.272 27.270
Max FY 78 202:1.4DD+1.4 -1.335 314.063 36.269 61.650 -1.405 6.467
Min FY 78 209:DL+1.4WL 0.760 -415.271 -30.094 -61.193 0.793 -3.614
Max FZ 80 206:1.4DL+1.4W -0.964 159.620 87.315 89.204 -0.962 5.000
Min FZ 78 209:DL+1.4WL 0.760 -415.271 -30.094 -61.193 0.793 -3.614
Max MX 80 206:1.4DL+1.4W -0.964 159.620 87.315 89.204 -0.962 5.000
Min MX 78 209:DL+1.4WL 0.760 -415.271 -30.094 -61.193 0.793 -3.614
Max MY 82 11:TEMP -VE 10.532 -13.001 7.101 15.192 4.318 -32.175
Min MY 82 215:1.2DL+0.5L -0.949 115.506 7.175 12.219 -9.056 15.784
Max MZ 82 10:TEMP +VE -10.532 13.001 -7.101 -15.192 -4.318 32.175
Min MZ 82 218:1.2DL+1.2L 21.831 142.577 17.884 34.168 3.502 -51.053

Y
X
Z Load 101

Whole Structure
Sheet of
Job no Designed by SAB
PROJECT CANOPY FRAMING
Date 6/29/2017 Checked by ASV

SUBJECT DESIGN OF CHS WELDED CONNECTION Reference BS EN 1993 1-1 2005

C)
DESIGN OF CHS WELD:
Member profiles
Supporting Member BASEPLATE

Supported Member CHS 355.6x12.5


2 3
D = 355.60 mm t1 = 12.50 mm A1 = 135.00 cm Z1 = 1117.00 cm
d = 330.6 mm

Design Input
Grade of material = S 275
Yield strength of the CHS member Py = 275.00 N/mm2
Yield strength of the Supporting Member Fy = 275.00 N/mm2
Strength of the weld pw = 220.00 N/mm2
Size of weld Sw = 12 mm PPBW

Member Forces (Ultimate Loads)


Check for CHS Weld

(Axial) Fx = 420 kN Fy
(Vertical shear ) Fy = 90 kN ( Consevatively) t

(Horizontal shear ) Fz = 25 kN Fx Fz
(Torsion) Mx = 10 kNm
(Minor moment) My = 55 kNm
(Major moment) Mz = 90 kNm D

Weld length Lw1 = *D Indicativily


= 1085.73 mm
Effective weld throat thickness a1 = (Sw-2)
= 10.00 mm
Area of weld Aw1 = Lw1*a1
2
= 10857.34 mm

Weld Stress due to axial force f1 = Fy/Aw1


= 38.68 N/mm2

Weld Stress due to vertical shear force f2 = Fx/Aw1


= 8.29 N/mm2
Weld
Weld Stress due to horizontal shear force f3 = Fz/Aw1 Outer dia D = 355.60 mm
= 2.30 N/mm2 Inner dia d = 335.60 mm
Radius r = 167.80 mm
Section modulus of weld Zxx & Zyy = 912000
= 9.1E+05 mm3

Weld Stress due to Major Moment f4 = Mx/Zxx


= 98.68 N/mm2

Weld Stress due to Minor Moment f5 = Mz/Zyy


= 60.31 N/mm2

Polar moment of Inertia of weld J = 2*(D4-d4)/64


= 3.24E+08 mm4

Weld Stress due to Torsion Moment f6 = My*r/J


= 2.59 N/mm2

Resultant stress of weld R = sqrt((f1+f4+f5)2+(f2+f3+f6)2)


= 198.11 N/mm2 < 275.00 N/mm2 Hence Safe.
Ratio = 0.72
www.hilti.com Profis Anchor 2.7.3
Company: Page: 1
Specifier: Project: CANOPY
Address: Sub-Project I Pos. No.: STEEL COLUMN BASE
Phone I Fax: | Date: 6/29/2017
E-Mail:

Specifier's comments: Tension & shear Reinforcement should be provided in the RC Pedestal As per Design Requirement.

1 Input data
Anchor type and diameter: Hex Head ASTM F 1554 GR. 55 1 1/8
Effective embedment depth: hef = 400 mm
Material: ASTM F 1554
Technical Information: Design Method ACI 349/CIP
Issued I Valid: -|-
Proof: Design Provisions of ACI349-01, Appendix B
Stand-off installation: without clamping (anchor); restraint level (anchor plate): 2.00; eb = 20 mm; t = 30 mm
Hilti Grout: , multipurpose, fc,Grout = 30.00 N/mm2
Anchor plate: lx x ly x t = 600 mm x 600 mm x 30 mm; (Recommended plate thickness: not calculated
Profile: Pipe; (L x W x T) = 356 mm x 356 mm x 13 mm
Base material: uncracked concrete, , fc' = 5802 psi; h = 600 mm
Reinforcement: anchor reinforcement: tension, shear
edge reinforcement: > No. 4 bar with stirrups
Anchor Design Option B.3.6.1

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.3
Company: Page: 2
Specifier: Project: CANOPY
Address: Sub-Project I Pos. No.: STEEL COLUMN BASE
Phone I Fax: | Date: 6/29/2017
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads

Anchor reactions [kN] 1 2 3 4


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 95.133 11.175 4.715 10.132 Tension
2 83.272 9.613 4.715 8.377 5 6
3 71.410 8.130 4.715 6.623
x
4 59.548 6.777 4.715 4.868
5 71.530 10.555 2.961 10.132
7 8
6 35.945 5.698 2.961 4.868
7 47.927 10.203 1.206 10.132
8 12.342 5.016 1.206 4.868
9 24.323 10.146 -0.548 10.132 9 10 11 12
10 12.462 8.395 -0.548 8.377 Compression
11 0.600 6.645 -0.548 6.623
12 0.000 4.899 -0.548 4.868
max. concrete compressive strain: 0.29 []
max. concrete compressive stress: 8.84 [N/mm2]
resulting tension force in (x/y)=(-61/126): 514.492 [kN]
resulting compression force in (x/y)=(208/-254): 99.492 [kN]

3 Tension load
Load Nu [kN] Capacity f Nn [kN] Utilization bN = Nu/f Nn Status
Steel Strength* 95.133 254.549 38 OK
Pullout Strength* 95.133 361.636 27 OK
Concrete Breakout Strength** 1 N/A N/A N/A N/A
Concrete Side-Face Blowout, direction 309.364 418.186 74 not recommendedA
y+**
* anchor having the highest loading **anchor group (anchors in tension)
1
Tension Anchor Reinforcement has been selected!
A
When B.3.6.1 is selected as the anchor design option, the design steel strength must be the governing design strength having the highest
utilization.

3.1 Steel Strength


Ns = n Ase fut ACI 349-01 Eq. (B-3)
f Nsteel Nu ACI 349-01 Eq. (B-1)

Variables
n Ase [mm2] fut [N/mm2]
1 492 517.11
Calculations
Ns [kN]
254.549
Results
Ns [kN] f steel f Ns [kN] Nu [kN]
254.549 1.000 254.549 95.133

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.3
Company: Page: 3
Specifier: Project: CANOPY
Address: Sub-Project I Pos. No.: STEEL COLUMN BASE
Phone I Fax: | Date: 6/29/2017
E-Mail:

3.2 Pullout Strength


Npn = y 4 Np ACI 349-01 Eq. (B-9)
Np = 8 Abrg f'c ACI 349-01 Eq. (B-10)
f Npn Nu ACI 349-01 Eq. (B-1)

Variables
y4 Abrg [mm2]
1.400 950
Calculations
Np [kN]
303.896
Results
Npn [kN] f concrete f Npn [kN] Nu [kN]
425.454 0.850 361.636 95.133

3.3 Concrete Side-Face Blowout, direction y+


Nsb = 160 c Abrg f'c ACI 349-01 Eq. (B-11)
Nsbg = agroup Nsb ACI 349-01 Eq. (B-12)
f Nsbg Nu ACI 349-01 Eq. (B-1)

(
agroup = 1 + 0
s
6c ) see ACI 349-01, Part B.5.4.2 Eq. (B-12)

Variables
c [mm] c2 [mm] Abrg [mm2] f'c [psi] s0 [mm]
115 275 950 5802 450
Calculations
agroup Nsb [kN]
1.652 297.779
Results
Nsbg [kN] f concrete f Nsbg [kN] Nu,edge [kN]
491.983 0.850 418.186 309.364

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.3
Company: Page: 4
Specifier: Project: CANOPY
Address: Sub-Project I Pos. No.: STEEL COLUMN BASE
Phone I Fax: | Date: 6/29/2017
E-Mail:

4 Shear load
Load Vu [kN] Capacity f Vn [kN] Utilization bV = Vu/f Vn Status
Steel Strength* 11.175 165.457 7 OK
Steel failure (with lever arm)* 11.175 23.183 49 OK
Pryout Strength** 93.408 409.483 23 OK
Concrete edge failure in direction ** 1 N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)
1
Shear Anchor Reinforcement has been selected!

4.1 Steel Strength


Vs = n 0.6 Ase fut ACI 349-01 Eq. (B-14)
f Vsteel Vu ACI 349-01 Eq. (B-2)

Variables
n Ase [mm2] fut [N/mm2]
1 492 517.11
Calculations
Vs [kN]
165.457
Results
Vs [kN] f steel f Vs [kN] Vu [kN]
165.457 1.000 165.457 11.175

4.2 Steel failure (with lever arm)


aM Ms
VM
s = bending equation for stand-off
Lb
Ms (
= M0s 1 - u
N
f Ns ) resultant flexural resistance of anchor
M0s = (1.2) (S) (fu,min) characteristic flexural resistance of anchor

( N
1- u
f Ns ) reduction for tensile force acting simultaneously with a shear force on the anchor
3
p(d)
S = elastic section modulus of anchor bolt at concrete surface
32
Lb = z + (n)(d0) internal lever arm adjusted for spalling of the surface concrete
f VM
s Vu ACI 349-01 Eq. (B-2)

Variables
aM fu,min [N/mm2] Nu [kN] f Ns [kN] z [mm] n d0 [mm]
2.00 517.11 95.133 254.549 35 0.500 29
Calculations

M0s [kNm] (1 - fNN ) u


s Ms [kNm] Lb [mm]
0.912 0.626 0.571 49
Results
VM
s [kN] f steel f VM
s [kN] Vu [kN]
23.183 1.000 23.183 11.175

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.3
Company: Page: 5
Specifier: Project: CANOPY
Address: Sub-Project I Pos. No.: STEEL COLUMN BASE
Phone I Fax: | Date: 6/29/2017
E-Mail:

4.3 Pryout Strength

Vcpg = kcp [(AA ) y


N
N0
1 y 2 y 3 Nb ] ACI 349-01 Eq. (B-21)
f Vcpg Vu ACI 349-01 Eq. (B-2)
AN see ACI 349-01R, Fig. RB.5.1
AN0 = 9 h2ef ACI 349-01 Eq. (B-5)

( )
1
y1 = 2 e'N 1.0 ACI 349-01 Eq. (B-7)
1+
3 hef
y2 = 0.7 + 0.3 (
cmin
1.5hef
1.0 ) ACI 349-01 Eq. (B-8)
1.5
Nb = k fc hef
'
ACI 349-01 Eq. (B-6a)

Variables
kcp hef [mm] e1,N [mm] e2,N [mm]
2 183 103 29

cmin [mm] y3 k f'c [psi]


115 1.250 24 5802

Calculations
AN [mm2] AN0 [mm2] y 1,1 y 1,2 y2 Nb [kN]
680000 302500 0.727 0.906 0.825 157.681
Results
Vcpg [kN] f concrete f Vcpg [kN] Vu [kN]
481.745 0.850 409.483 93.408

5 Combined tension and shear loads


bN bV z Utilization bN,V [%] Status
0.740 0.482 5/3 91 OK
bNV = bzN + bzV <= 1

6 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
ACI349-01 does not specifically address anchor bending when a stand-off condition exists. PROFIS Anchor calculates a shear load
corresponding to anchor bending when stand-off exists and includes the results as a Design Strength!
Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI349-01 or the relevant
standard!
ACI 349-01, Appendix B, Part B.3.6.1 requires the governing design strength of an anchor or group of anchors to be limited by ductile steel
failure. If this is NOT the case, Part B.3.6.2 requires the attachment to be designed to undergo ductile yielding at a load level corresponding
to anchor forces not greater than 75% of the controlling design strength. In lieu of B.3.6.1 and B.3.6.2, the minimum design strength of the
anchors shall be multiplied by a reduction factor (f nonductile) per B.3.6.3
Pryout Strength can control the shear design if edge distances are large. When checking the Design Shear Strength per B.3.6.1, the Design
Concrete Breakout Strength and the Design Pryout Strength will be multiplied by a factor 0.85 and compared to 0.65 Ns
The design of Anchor Reinforcement is beyond the scope of PROFIS Anchor. Refer to ACI349-01, Part B.4.2.1 and the Commentary
RB.4.2.1
Please note that this PROFIS software is not produced or supplied under Hilti's 10CFR50, Appendix B compliant Nuclear Quality Program

Fastening does not meet the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.3
Company: Page: 6
Specifier: Project: CANOPY
Address: Sub-Project I Pos. No.: STEEL COLUMN BASE
Phone I Fax: | Date: 6/29/2017
E-Mail:

7 Installation data
Anchor plate, steel: - Anchor type and diameter: Hex Head ASTM F 1554 GR. 55 1 1/8
Profile: Pipe; 356 x 356 x 13 mm Installation torque: -
Hole diameter in the fixture: df = 30 mm Hole diameter in the base material: - mm
Plate thickness (input): 30 mm Hole depth in the base material: 400 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 432 mm
Drilling method: -
Cleaning: No cleaning of the drilled hole is required

300 300

75
1 2 3 4

150

300
5 6

150
x

7 8
150

300

9 10 11 12
75

75 150 150 150 75

Coordinates Anchor mm
Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -225 225 275 725 565 115 7 -225 -75 275 725 265 415
2 -75 225 425 575 565 115 8 225 -75 725 275 265 415
3 75 225 575 425 565 115 9 -225 -225 275 725 115 565
4 225 225 725 275 565 115 10 -75 -225 425 575 115 565
5 -225 75 275 725 415 265 11 75 -225 575 425 115 565
6 225 75 725 275 415 265 12 225 -225 725 275 115 565

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.3
Company: Page: 7
Specifier: Project: CANOPY
Address: Sub-Project I Pos. No.: STEEL COLUMN BASE
Phone I Fax: | Date: 6/29/2017
E-Mail:

8 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
WALL EMBED DETAILS

HIT-HY 200-R + HIT-V-F (8.8) M20 HILTI BOLT EMBED=200mm

FPBW ALL
AROUND

UB533X210X101


Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max FX 97 216:1.2DL+0.5L 3.172 29.190 -30.717 0.000 0.000 0.000
Min FX 97 215:1.2DL+0.5L -10.677 29.149 -17.778 0.000 0.000 0.000
Max FY 97 202:1.4DD+1.4 -3.847 69.307 -37.070 0.000 0.000 0.000
Min FY 99 207:DL+1.4WL -2.832 -55.503 9.029 0.000 0.000 0.000
Max FZ 98 210:DL+1.4WL -1.561 8.103 58.451 0.000 0.000 0.000
Min FZ 97 202:1.4DD+1.4 -3.847 69.307 -37.070 0.000 0.000 0.000
Max MX 97 201:1.4DL+1.6L -3.032 50.845 -26.966 0.000 0.000 0.000
Min MX 97 201:1.4DL+1.6L -3.032 50.845 -26.966 0.000 0.000 0.000
Max MY 97 201:1.4DL+1.6L -3.032 50.845 -26.966 0.000 0.000 0.000
Min MY 97 201:1.4DL+1.6L -3.032 50.845 -26.966 0.000 0.000 0.000
Max MZ 97 201:1.4DL+1.6L -3.032 50.845 -26.966 0.000 0.000 0.000
Min MZ 97 201:1.4DL+1.6L -3.032 50.845 -26.966 0.000 0.000 0.000

Y
X
Z Load 1

Whole Structure
www.hilti-me.com Profis Anchor 2.7.3
Company: GERMAN STEEL CONTRACTING L.L.C Page: 1
Specifier: SAB/ASV Project: CANOPY FRAMING
Address: AJMAN Sub-Project I Pos. No.:
Phone I Fax: | Date: 6/30/2017
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 200-R + HIT-V-F (8.8) M20
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 200 mm (hef,limit = - mm)
Material: 8.8
Evaluation Service Report: ETA 12/0084
Issued I Valid: 2/3/2017 | -
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 16 mm
Anchor plate: S 235 (St 37); E = 210000.00 N/mm2; fyk = 235.00 N/mm2; gMs = 1.100
lx x ly x t = 600 mm x 253 mm x 16 mm; (Recommended plate thickness: calculated (9 mm))
Profile: IPE; (L x W x T x FT) = 533 mm x 210 mm x 16 mm x 8 mm
Base material: uncracked concrete, , fc,cyl = 20.00 N/mm2; h = 350 mm, Temp. short/long: 30/30 C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: GERMAN STEEL CONTRACTING L.L.C Page: 2
Specifier: SAB/ASV Project: CANOPY FRAMING
Address: AJMAN Sub-Project I Pos. No.:
Phone I Fax: | Date: 6/30/2017
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y 1 5 2
1 6.333 11.810 11.667 1.833
2 6.333 11.810 11.667 1.833 x
Tension
3 6.333 11.810 11.667 1.833
3 6 4
4 6.333 11.810 11.667 1.833
5 6.333 11.810 11.667 1.833
6 6.333 11.810 11.667 1.833
max. concrete compressive strain: - []
max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 38.000 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN]

3 Tension load SOFA (fib (07/2011), section 16.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 6.333 130.667 5 OK
Combined pullout-concrete cone failure** 38.000 174.161 22 OK
Concrete Breakout Strength** 38.000 85.706 45 OK
Splitting failure** 38.000 87.704 44 OK
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
196.000 1.500 130.667 6.333

3.2 Combined pullout-concrete cone failure


Ap,N [mm2] A0p,N [mm2] y A,Np
2
t Rk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
240000 90000 2.667 15.00 566 283 140
h'ef [mm] c'cr,Np [mm] s'cr,Np [mm]
106 150 300
2 0
yc t Rk,ucr [N/mm ] max t Rk,ucr [N/mm2] y g,Np y g,Np
1.000 15.00 8.06 1.000 1.000
ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np
0 1.000 0 1.000 0.980 1.000
N0Rk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
99.965 261.242 1.500 174.161 38.000

3.3 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm]
240000 90000 2.667 300 600
h'ef [mm] c'cr,N [mm] s'cr,N [mm]
100 150 300
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 0.980 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
11.000 49.193 1.500 85.706 38.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: GERMAN STEEL CONTRACTING L.L.C Page: 3
Specifier: SAB/ASV Project: CANOPY FRAMING
Address: AJMAN Sub-Project I Pos. No.:
Phone I Fax: | Date: 6/30/2017
E-Mail:

3.4 Splitting failure


Ac,N [mm2] A0c,N [mm2] y A,N ccr,sp [mm] scr,sp [mm] y h,sp
296000 336400 0.880 290 580 1.272
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N k1
0 1.000 0 1.000 0.845 1.000 11.000
N0Rk,c [kN] gM,sp NRd,sp [kN] NSd [kN]
139.140 1.500 87.704 38.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: GERMAN STEEL CONTRACTING L.L.C Page: 4
Specifier: SAB/ASV Project: CANOPY FRAMING
Address: AJMAN Sub-Project I Pos. No.:
Phone I Fax: | Date: 6/30/2017
E-Mail:

4 Shear load SOFA (fib (07/2011), section 16.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 11.810 78.400 16 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 70.859 171.412 42 OK
Concrete edge failure in direction y+** 35.430 52.488 68 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
98.000 1.250 78.400 11.810

4.2 Pryout Strength (Concrete Breakout Strength controls)


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm] k4
240000 90000 2.667 300 600 2.000
h'ef [mm] c'cr,N [mm] s'cr,N [mm]
100 150 300
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 0.980 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
49.193 1.500 171.412 70.859

4.3 Concrete edge failure in direction y+


lf [mm] dnom [mm] kV a b
200 20.0 2.400 0.088 0.060
c1 [mm] Ac,V [mm2] A0c,V [mm2] y A,V
260 294000 304200 0.966
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V y 90,V
0.815 1.056 2.355 0 1.000 1.000 2.500
V0Rk,c [kN] n1 gM,c VRd,c [kN] VSd [kN]
80.363 2 1.500 52.488 35.430
Note: Resistance limit acc. to fib (07/2011) Eq. (10.2-6) is governing

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.048 0.151 2.000 3 OK
concrete 0.443 0.675 1.500 85 OK

baN + baV <= 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: GERMAN STEEL CONTRACTING L.L.C Page: 5
Specifier: SAB/ASV Project: CANOPY FRAMING
Address: AJMAN Sub-Project I Pos. No.:
Phone I Fax: | Date: 6/30/2017
E-Mail:

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 4.691 [kN] dN = 0.037 [mm]
VSk = 9.059 [kN] dV = 0.362 [mm]
dNV = 0.364 [mm]
Long term loading:
NSk = 4.691 [kN] dN = 0.056 [mm]
VSk = 9.059 [kN] dV = 0.544 [mm]
dNV = 0.546 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
Characteristic bond resistances depend on short- and long-term temperatures.
Please contact Hilti to check feasibility of HIT-V rod supply.
The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
The compliance with current standards (e.g. EC3) is the responsibility of the user
Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: GERMAN STEEL CONTRACTING L.L.C Page: 6
Specifier: SAB/ASV Project: CANOPY FRAMING
Address: AJMAN Sub-Project I Pos. No.:
Phone I Fax: | Date: 6/30/2017
E-Mail:

8 Installation data
Anchor plate, steel: S 235 (St 37); E = 210000.00 N/mm2; fyk = 235.00 N/mm2 Anchor type and diameter: HIT-HY 200-R + HIT-V-F (8.8) M20
Profile: IPE; 533 x 210 x 16 x 8 mm Installation torque: 0.150 kNm
Hole diameter in the fixture: df = 22 mm Hole diameter in the base material: 22 mm
Plate thickness (input): 16 mm Hole depth in the base material: 200 mm
Recommended plate thickness: calculated (9 mm) Minimum thickness of the base material: 244 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to instructions for use is required

8.1 Recommended accessories

Drilling Cleaning Setting


Suitable Rotary Hammer Compressed air with required Dispenser including cassette and mixer
Properly sized drill bit accessories to blow from the bottom of Seismic/Filling set
the hole Torque wrench
Proper diameter wire brush

300 300

67

127
1 5 2
120

x
127

3 6 4
67

150 150 150 150

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -150 60 150 - 260 140 4 150 -60 450 - 140 260
2 150 60 450 - 260 140 5 0 60 300 - 260 140
3 -150 -60 150 - 140 260 6 0 -60 300 - 140 260

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com Profis Anchor 2.7.3
Company: GERMAN STEEL CONTRACTING L.L.C Page: 7
Specifier: SAB/ASV Project: CANOPY FRAMING
Address: AJMAN Sub-Project I Pos. No.:
Phone I Fax: | Date: 6/30/2017
E-Mail:

9 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 319 282 218:1.2DL+1.2L 62.027 0.085 0.000 0.002 0.000 0.000
Min Fx 319 282 217:1.2DL+1.2L -62.251 0.085 0.000 0.004 0.000 0.000
Max Fy 346 311 201:1.4DL+1.6L -3.153 0.361 -0.000 0.000 0.000 0.000
Min Fy 346 336 201:1.4DL+1.6L -3.153 -0.361 -0.000 0.000 -0.000 -0.000
Max Fz 252 218 217:1.2DL+1.2L 3.059 0.085 0.000 0.004 0.000 0.000
Min Fz 252 218 218:1.2DL+1.2L -3.240 0.085 -0.000 0.004 0.000 0.000
Max Mx 164 123 202:1.4DD+1.4 -0.438 0.099 0.000 0.030 0.000 0.000
Min Mx 165 131 202:1.4DD+1.4 0.437 0.099 -0.000 -0.035 0.000 0.000
Max My 164 123 1:EQ +X -1.484 0.000 0.000 -0.000 0.000 0.000
Min My 164 123 1:EQ +X -1.484 0.000 0.000 -0.000 0.000 0.000
Max Mz 164 123 1:EQ +X -1.484 0.000 0.000 -0.000 0.000 0.000
Min Mz 164 123 1:EQ +X -1.484 0.000 0.000 -0.000 0.000 0.000

R5
R5 R5 R5
R5 R5 R5 R5
R5 R5 R5 R5
R5 R5 R5
R5 R5 R5 R5
R5 R5 R5
R5 R5
R5 R5 R5 R5
R5 R5 R5
R5 R5
R5 R5 R5
R5 R5 R5 R5
R5 R5 R5 R5
R5 R5
R5 R5
R5 R5 R5 R5
R5 R5 R5
R5 R5 R5
R5 R5 R5 R5
R5 R5 R5
R5 R5 R5
R5 R5 R5 R5
R5 R5
R5 R5 R5 R5
R5 R5 R5 R5
R5 R5
R5 R5
R5 R5 R5 R5
R5 R5
R5 R5 R5 R5
R5
R5
R5R5 R5 R5
R5 R5
R5R5 R5 R5
R5R5 R5 R5
R5 R5
R5R5 R5 R5
R5
R5R5 R5 R5
R5R5 R5 R5 R5 R5
R5 R5

Y
X
Z Load 1

Whole Structure
Jun 29, 2017
SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN
(FLEXIBLE SUPPORT CONNECTION)
Connection Identification - D-03
INPUT DATA TO BE PROVIDED :
Supporting Member UB 356x171x51 Column Flange
D = 355.0 mm r = 10.2 mm Weight = 51.0 kG/m
B = 171.5 mm D' = 311.6 mm
tw = 7.4 mm A = 64.9 cm2
Tf = 11.5 mm
Supported Member UB 254x102x22 Beam Web (Rolled Section)
D = 254.0 mm r = 7.6 mm Weight = 22.0 kG/m
B = 101.6 mm D' = 225.2 mm
tw = 5.7 mm A = 28.0 cm2
Tf = 6.8 mm

Member end actions


Factored Axial Forces
Compression = 75 kN Tension = 75 kN Vertical Shear Fv1 = 20 kN
Factored Tying Forces Vertical Shear Fv2 = 0 kN
Compression = 75 kN Tension = 75 kN
Connection Web of supported member
Grade of bolts = Gr. 8.8
Type of Connection >> Bearing Connections = Non-Preloaded Bolts

Shear Strength of Bolt (Table.30, BS5950-1:2000) ps = 375 M Pa

Tensile Strength of Bolt (Table.34, BS5950-1:2000) pt = 560 M Pa


Design Strength of Weld pw = 250 M Pa
Grade of material -Member = S 275 M Pa Plate = S 275 M Pa
Minimum Tensile Strength -Member Us.b = 410 M Pa Plate Us.f = 410 M Pa
Minimum Yield Strength (Supported) Ys.b = 275 M Pa Fin Plate Ys.f = 275 M Pa
(Design Strength, py = 1.0Ys < Us/1.2) (Supporting) Ys.b = 265 M Pa Rein. Plate Ys.f = N.A. M Pa
Bearing Strength -Member pbs.b = 460 M Pa Plate pbs.f = 460 M Pa
Diameter of bolt d = 24 mm
Diameter of bolt hole Dh = 26 mm
Nr of bolt columns nc = 2
Nr of bolt rows nr = 2
Spacing of bolt rows (pitch) p = 70 mm
Spacing of bolt columns (gauge) g = 60 mm
Horizontal Edge distance for plate e2 = 50 mm
Vertical End distance in plate at top e1 = 50 mm
Vertical End distance in plate at bottom e1.1 = 50 mm
Vertical End distance in member at top et = 50 mm
Vertical End distance in member at bottom eb = 50 mm
Horizontal Edge distance for member e3 = 50 mm
Distance between face of supporting member & supported beam (End Projection) t1 = 15 mm
Thickness of fin plate tp' = 10 mm
Thickness of reinforcement plate (doubler plate) twrp = 0 mm
Nr of shear planes Ns = 1
2 2
Sum of square of 'r' for the bolt group r = 8,500 mm

Minimum Shank Tension P0 = N.A. kN


Hole Factor for Standard Size Holes kbs = 1
Slip factor for Class A m = N.A.
Leg length of the fillet weld s = 6 mm
Hole Factor for Standard Size Holes (For Axial force) kbs = 1
Lenght of fin plate, l = 170.0 mm Depth of top notch dct = 0 mm
Width of fin plate, Bf = 175.0 mm Depth of bottom notch dcb = 0 mm
Thickness of fin plate, tp = 10.0 mm Effective Net Area Co-efficient Ke = 1.2 (For Plate)
TOS to first bolt hole = 75.0 mm Ke = 1.2 (For Section)
Fin Plate Type = Extended:Stiffened
Jun 29, 2017
SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN

D-03 00

0.598 Web strengthening stiffener for the supporting member is not required.
Safe. Bearing capacity per bolt Pbs = 62.93 kN > Fs ( 37.64 )
0.598 (Bearing of bolts on the fin plate and beam web)
Safe. Shear Capacity per bolt Ps = 132.32 kN > Fs ( 37.64 )
0.284
Safe. Shear capacity of fin plate Pv.min = 233.31 kN > Fv ( 20.00 )
0.086
Safe. Moment capacity of fin plate Mc = 13.2 kN.m > Fv a ( 2.94 )
0.222 (Shear and bending interaction)
N.A. Lateral Torsional buckling resistance = N.A. kN.m > Fv a ( N.A. )
moment of fin plate Short fin plate, This check is not required
Safe. Tension capacity of fin plate = 287 kN >T ( 75.00 )
0.261
Safe. Compression Capacity of fin plate = 374 kN >C ( 75.00 )
0.200
Safe. Shear capacity of the beam at Pv.min = 155.37 kN > Fv ( 20.00 )
0.129 the connection
N.A. Moment capacity of the notched beam = N.A. kN.m > Mnc ( N.A. )
th
(Shear and bending interaction at n col. of bolts) Since the beam is not notched, this check is not required.
N.A. Moment capacity of the beam web = N.A. kN.m > Fv{ a+(nc-1)*g} ( N.A. )
(Shear and bending interaction of the beam web) Short fin plate, This check is not required
Safe. Tension capacity of Supported beam = 164 kN >T ( 75.00 )
0.458
N.A. Moment capacity of beam at the notch = N.A. kN.m < McN ( N.A. )
in the presence of shear Since the beam is not notched, this check is not required.
N.A. Local stability of notched beam Since the beam is not notched, this check is not required.
Safe. Weld connecting fin plate to supporting = 0.036 < 1 ( 6.00 mm)
0.036 beam / column (Utilization ratio)
N.A. Local shear capacity of supporting beam = N.A. kN > Fv/2 ( N.A. )
Since the beam Supported by Column Flange, this check is not required.
N.A. Punching shear capacity of supporting beam = N.A. mm > tp ( N.A. )
Since the beam Supported by Column Flange, this check is not required.
N.A. Local shear capacity of supporting beam = N.A. kN > Fv1A/2+Fv2/2 ( N.A. )
web or column web supporting two beams:
Recommended detailing practice is satisfied.
Structural Integrity Checks (For Tying Force)
These checks are only needed if it is necessary to comply with structural integrity requirements.
Safe Weld connecting fin plate to supporting = 0.179 < 1 ( 6.00 mm)
0.179 beam / column (Utilization ratio)
Safe. Tension capacity of fin plate = 185.0 kN > Tie Force ( 75.00 )
0.405
Safe. Bearing capacity of fin plate = 561.2 kN > Tie Force ( 75.00 )
0.134
Safe. Tension capacity of beam web = 185.0 kN > Tie Force ( 75.00 )
0.405
Safe. Bearing capacity of beam web = 319.9 kN > Tie Force ( 75.00 )
0.234
N.A. Tying capacity of web of supporting member = N.A. kN > Tie Force ( 75.00 )
Web strengthening stiffener for the supporting member is not required.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000

SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN

Connection identification D-03

Supporting member D1 = 355.0 mm tw1 = 7.4 mm r1 = 10.2 mm


(Beam / Column) B1 = 171.5 mm Tf1 = 11.5 mm D'1 = 311.6 mm
UB 356x171x51 A1 = 64.9 cm2

Supported Beam D2 = 254.0 mm tw2 = 5.7 mm r2 = 7.6 mm


UB 254x102x22 B2 = 101.6 mm Tf2 = 6.8 mm D'2 = 225.2 mm
A2 = 28.0 cm2
Member End Actions
Factored
Compressive force C = 75.0 kN
Tensile force T = 75.0 kN
Vertical Shear force Fv = 20.0 kN
Tying force Tf = 75.0 kN
Web connection
Connection details
Grade of bolt = Gr. 8.8 Bearing Connections
Grade of material Rolled sections = S 275 Plates - S 275
Minimum Tensile Strength Us.b = 410.0 M Pa Us.f = 410.0 M Pa
Minimum Yield Strength = Design strength Supported beam: py.b = 275.0 M Pa Fin Plate: py.f = 275.0 M Pa
Minimum Yield Strength = Design strength Supporting beam: py.b = 265.0 M Pa Reinforcement p py.f = N.A. M Pa
Bearing Strength pbs.b = 460.0 M Pa pbs.f = 460.0 M Pa
Shear Strength of Bolt ps = 375.0 M Pa
Tensile Strength of Bolt pt = 560.0 M Pa
Bearing Strength of bolt pbb = 1000.0 M Pa
Minimum Shank Tension Po = N.A. kN
Design Strength of Weld pw = 250.0 M Pa
Diameter of bolt d = 24.0 mm
Diameter of bolt hole Dh = 26.0 mm
Area of one nominal bolt Ab = 452.4 mm2
Effective area of one bolt At = 352.9 mm2
Nr of bolt column nc = 2
Nr of bolt rows nr = 2
Nr of bolts n = 4
Spacing of bolt rows (pitch) p = 70.0 mm
Spacing of bolt coumns (gauge) g = 60.0 mm
Horizontal Edge distance for member e3 = 50.0 mm
Horizontal Edge distance for plate e2 = 50.0 mm
Vertical End distance in plate at top e1 = 50.0 mm
Vertical End distance in plate at bottom e1.1 = 50.0 mm
Vertical End distance in member at top et = 50.0 mm
Vertical End distance in member at bottom eb = 50.0 mm
Dist. between face of supporting mem. & supported beam t1 = 15.0 mm (End Projection)
Length of fin plate lf = 170.0 mm
Width of fin plate Bf = 175.0 mm
Thickness of fin plate tp = 10.0 mm ( 1 - 10 mm plate )
Thickness of reinforcement twrp = 0.0 mm
Total thickness of web tw = 5.7 mm
Least thickness of connected parts t = 5.7 mm
Nr of shear planes Ns = 1
Sum of square of 'r' for the bolt group r
2
= 8500.0 mm2
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000
Check 1 : Recommended detailing practice
Length of fin plate l = 50 + (1 * 70 )+ 50 >= 0.6D2
(To give adequate "nominal torsional restraint" = 170.0 mm ( 152.4 ) Safe.
BS 5950-1 Table 13 and cl.4.2.2)
Spacing of Bolts
Minimum spacing of bolts = 2.5 d <= Min.(p,g)
= 60.0 mm ( 60.0 ) Safe.
Maximum spacing of bolts = 14 t > Max.(p,g)
= 79.8 mm ( 70.0 ) Safe.
End & Edge Distances of Bolts
Minimum end and edge distances of bolts = 1.25 Dh <= Min.(e1, e1.1, e2,e3, et, eb)
= 32.5 mm ( 50.0 ) Safe.
Maximum end and edge distances of bolts = 11 t > Max.(e1, e1.1, e2,e3)
= 62.7 mm ( 50.0 ) Safe.
Type of fin plate based on the length, tp / a = 0.154 >= 0.15, Short fin plate
Recommended detailing practice is satisfied.
Check 2: Supported beam - Bolt Group
Basic Requirement ( Bearing of bolts on fin plate and beam web)
Fs < Pbs
Vertical Reaction Fv = 20.0 kN
Eccentricity of FV about c.g. of bolt group e = 0.5*(B1-tw1)+ t1+e3+0.5
For shear connection
= 177.1 mm
Moment due to eccentricity M = FV*e e = 177.05
= 3.54 kN.m
2 2
Distance of outermost bolt from cg of bolt group r = Sqrt(((nc-1)*g/2) +((nr-1)*p/2) )
= 46.1 mm
2 2
Sum of square of 'r' for all bolts r = 8,500.0 mm
Vertical force on a bolt due Fsv = Fv/n
to direct shear = 5.00 kN
Horizontal force on a bolt due Fah = Max (C , T)/n
to Axial Force = max(75 , 75) /4
= 18.75 kN
2
Maximum shear in bolt due to M Fm = Me*r/Er
= 19.20 kN
Vertical force on the outermost bolt Fsmv = Fm * cosq q = 49.4
due to moment M, = 12.50 kN
Horizontal force on the outermost bolt Fsmh = Fm * sinq
due to moment M, = 14.58 kN
Total vertical force on a bolt Fvb = Fsv + Fsmv
= 17.50 kN
Total horizontal force on a bolt Fhb = Fah + Fsmh
= 33.33 kN
Resultant force on outermost bolt Fs = Sqrt (Fvb2 + Fhb2)
= 37.64 kN

Bearing Capacity per bolt Pbs = Min. (Pbs.f , Pbs.b ) (Indicative)


Bearing Strength of the plate per bolt Pbs.f = kbs*d*tp*pbs.f < 0.5 * kbs*min.(e1, e1.1,e2)*tp*pbs.f
= 110.40 kN where, kbs = 1.0
for Standard Size Holes
Bearing Strength of the web per bolt Pbs.b = kbs*d*tw*pbs.b < 0.5 * kbs*min.(et, eb,e3)*tw*pbs.b
= 62.93 kN where, kbs = 1.0
for Standard Size Holes
Bearing Capacity per bolt Pbs = 62.93 kN > Fs Safe.
( 37.6 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000
Shear Capacity per bolt Ps = Min. (Ps1 & Ps2 below)
1.0 Shear capacity per bolt with no reductions Ps1 = ps * As * Ns where, As = At
= 132.3 kN
2.0 Shear capacity per bolt with reduction for large grip length
(if total thickness of connected plies, Tg > 5d) Ps = ps * As * Ns * { 8d / (3d+Tg)}
where, Tg = 15.7 mm & 5d = 120.0 mm. = 132.3 * 2.19
Ps2 = N.A. kN ( Tg<5d)
3.0 Shear capacity reduction for Long Joint Ps = ps * As * Ns * { 5500-Lj / 5000}
Lj = 70 mm 132.3 * 1.09 ( Lj<500)
Ps3 N.A. kN
Shear Capacity per bolt Ps = 132.3 kN > Fs Safe.
( 37.6 )
Connection designed to be Non-Slip under factored loads
Slip resistance of one bolt PSL = N.A.
= N.A.
Slip factor m = N.A.
Minimum Shank Tension Po = N.A.
PSL = N.A.
Shear Capacity per bolt Pb = 132.3 kN > Fs Safe.
( 37.6 )

Check 3: Supported beam - Connecting elements


Shear and bending capacity of fin plate connected to supported beam
(i) For Shear:
Basic requirement, Fv < Pv.min
Shear capacity of fin plate Pv.min = Min.{Plain shear capacity (Pv) , Block shear capacity (Pr1)}
Plain shear capacity of fin plate Pv = Min. (0.6pyAv , 0.7pyKe Av.net)
Shear Area Av = 0.9 [e1+e1.1+(nr-1)p] tp
= 1530.00 mm2
Net Shear Area after deducting holes Av.net = Av - nr*Dh*tp
= 1010.00 mm2
Effective net area coefficient Ke = 1.20
Plain shear capacity of fin plate Pv = Min. { 252.45 kN, 233.31 kN }
= 233.31 kN
Block shear capacity of fin plate Pr1 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 120.00 mm
Length of tension face Lt = 110.00 mm
Coefficient k = 2.50
Pr1 = 287.10 kN Pr1
Block shear capacity of fin plate Pr = Pr1 = 287.10 kN
Shear capacity of fin plate Pv.min = 233.31 kN > Fv Safe.
( 20.0 )
(ii) Shear and bending interaction
Basic requirement, Fv a < Mc
For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of fin plate Fv <= 0.75 Pv.min
Mc = py * tp (e1+e1.1+(nr-1)p)2 Low Shear
*
6
= 13.25 kN-m
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of fin plate
Mc = py * tp * (e1+e1.1+(nr-1)p)2 * { 1 - (Fv/Pv.min)^2 }1/2
6
= N.A. kN-m
Moment capacity of fin plate Mc = 13.25 kN-m > Fv a Safe.
( 2.9 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000

(iii) Lateral torsional buckling resistance of long fin plates * This check is not required for short fin plate

Basic requirement, Fv a < Mb / mLT &


Fv a < py Zx
Lateral torsional buckling moment of resistance of fin plate,
Mb = pb Z x
Elastic modulus of fin plate about major axis Zx = tp * l 2
6
Zx = 48,166.7 mm3
LT = 2.8 * { Lel / 1.5tp2}^1/2 (cl. B.2.7, BS5950-1:2000)
Le = 1 a
Le = 65.00 mm
LT = 24.03
mLT = 0.60 (Table 18 of BS5950-1 2000)
pE * py
Bending strength of fin plate pb = 2
LT + (LT -pEpy )^0.5

E / LT2
2
pE =
= 3503.21 M Pa
LT = [py + ( LT+1) pE] / 2
Robertson constant LT = 7.00 (Cl. B.2.2 of BS5950-1 2000)
Limiting slenderness ratio Lo = 0.4 (2 E / py )^0.5
= 34.31
Perry factor LT = 0.00
LT = 1889.11 M Pa
Bending strength of fin plate pb = 275.00 M Pa
Lateral torsional buckling resistance Mb = pb Z x
moment of fin plate = N.A. kN-m
Mb / mLT = N.A. kN-m > Fv a N.A.
( N.A. )
py Zx = N.A. kN-m > Fv a N.A.

(iv) Tension Capacity


Basic requirement, T < Min ( Ptf, Prf)
Tensile capacity of fin plate Ptf = py*Aeff
Aeff = Ke*An < Ag
An = (l-nr*Dh)*tp
= 1180 mm2
Ke = 1.2
Aeff = 1416 mm2
= 389 kN

Block Shear Capacity of Fin plate Prf = Min(Pr1, Pr2)


Pr2 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 220 mm
Length of tension face Lt-kDh = 44 mm
Pr2 = 450 kN Pr1 Pr2

Block Shear Capacity of Fin plate Prf = 287 kN (Indicative)

Tension Capacity of fin plate = 287 kN > T


(Tension Yielding & Block Shear) ( 75.0 ) Safe.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000
(v) Compression Capacity
Basic requirement, C < Pcf
Compression Capacity of fin plate Pc = pc*Ag
Area of fin plate Ag = l *tp
2
= 1700 mm
Unsupported length L = t1+e3+((B1-tw1)/2)
= 147.05 mm
Effective Length Leff = 1.2L
= 176 mm Table 24 for Curve 'b' in BS:5950:1:2000
Radius of gyration rmin = t/sqrt(12) Py = 275
= 2.89 mm
Slenderness ratio = Leff/rmin pc
= 61.1 72.00 236.00
Width of fin plate (Whitmore section of 30 deg) w = 69.3 61.1 268.62
Compressive stress area = 1393 mm2 74.00 230.00
(Min of Ag & Awhitmore)
Pcf = 374 kN > C
( 75.0 ) Safe.

Check 4: Supported beam - Capacity at the connection


Shear and bending capacity of supported beam
(i) For Shear:
Basic requirement, Fv < Pv.min
Shear capacity of the beam at the connection Pv.min = Min (Pv, Pr1)
Plain shear capacity of beam Pv = Min. (0.6pyAv , 0.7pyKe Av.net)
Shear Area Av = (et+eb+(nr-1)*p)*tw
= 969.00 mm2
Net Shear Area after deducting holes Av.net = Av - nr*Dh*tw
= 672.60 mm2
Effective net area coefficient Ke = 1.20
Plain shear capacity of beam Pv = Min. { 159.89 kN, 155.37 kN }
= 155.37 kN
Block shear capacity of beam Pr1 = 0.6 py tw [Lv+Ke(Lt-kDh)]
(Applicable to notched beams only)
Length of shear face Lv = 120.00 mm
Length of tension face Lt = 110.00 mm
Coefficient k = 2.50
Block shear capacity of beam Pr1 = 163.65 kN (Indicative)

Shear capacity of the beam at the connection, Pv.min = 155.37 kN > Fv Safe.
( 20.0 )

(ii) Shear and bending interaction at the nth column line of bolts, if the notch length c > (e3+g)

Basic requirement, Mnc < McC


where Mnc = Fv (t1+e3+(nc-1)*g)
Depth of top notch dct = 0.0 mm
Depth of bottom notch dcb = 0.0 mm
Length of notching c = 0.0 mm No Notching. This check is not required.
Since the beam is not notched, this check is not required.
Design load Fv = 20.0 kN
Eccentricity for Fv (t1+e3+(nc-1)*g) = 0 mm
th
Moment at the n column line of bolts Mnc = 0.0 kN.m.
Depth of beam web at notched section Dc = 240.4 mm
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000
Breadth of flange B2'
= 101.6 mm
Area of web at notched section Aw'
= tw*Dc
= 1370.3 mm2
Area of flange at notched section Af' = tf2*B2
= 690.9 mm2
Distance of c.g. from soffit of the beam c1 = D2/2
= 127.00 mm
M.I. of the notched section I' = N.A. cm4
Extreme fibre distance ymax = 127.0 mm
3
Sectional modulus at notched section Z = N.A. cm
For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of the notched beam
at the connection in the presence of shear, McC = py Z
McC = N.A. kN.m.
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of the notched beam
at the connection in the presence of shear, McC = 1.5 * py * Z * { 1 - (Fv/Pv.min)^2 }^0.5
= N.A. kN-m
Moment capacity of the notched beam at the connection in the presence of shear,
McC = N.A. kN-m > Mnc N.A.
( N.A. )

(iii) Shear and bending interaction of the beam web section - Long fin plates only * This check is not required for short fin plate

Basic requirement, Fv { a+ (nc-1)*g} < McBC + PVAB (nr-1)p

For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of the beam web BC
Mc BC = py tw [(nr-1)p]2
6
= 1.28 kN-m
Shear capacity of the beam web AB Pv AB = Min {( 0.6 py (e3+(nc-1)g)tw),
(0.7pyKe(e3+(nc-1)g+0.5Dh-ncDh)tw)}
= Min. { 103 kN , 93.49 kN }
Pv AB = 93.49 kN
Shear capacity of the beam web BC Pv BC = Min {( 0.6 py (nr-1)p)tw),
(0.7pyKe((nr-1)p+Dh-nrDh)tw)}
= Min. { 65.84 kN , 57.93 kN }
Pv BC = 57.93 kN
Shear force on the beam web BC Fv BC = Fv - (Pv - PVBC ) but > 0
= 0.00 kN
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of the beam web BC
py tw [(nr-1)p]2
Mc BC = * {1-(FvBC/PvBC)2}^0.5
4
= N.A. kN-m
Moment capacity of the beam web BC Mc BC = N.A. kN-m
McBC + PVAB (nr-1)p = N.A. kN-m > Fv { a+ (nc-1)*g}
( N.A. ) N.A.
(iv) Tension Capacity
Basic requirement, T < Ptb
Net Tension Capacity of supported beam = Le * tw * pbs
Le = 2ee + (n-1)pe - nDh
ee = Min(e3+(nc-1)*g-Dh, et)
= 50.0 mm
pe = Min(p, 2(e3+(nc-1)*g-Dh))
= 70.00 mm
Le = 118.0 mm
Net Tension Capacity of beam web = 185.0 kN
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000

Block Shear Capacity of Supported beam Prb = Min(Pr1, Pr2)


Pr2 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 220 mm
Length of tension face Lt-kDh = 44 mm
Pr2 = 257 kN Pr1 Pr2
Block Shear Capacity of Fin plate Prf = 164 kN (Indicative)

Tension Capacity of supported beam = 164 kN > T


(Tension Yielding & Block Shear) ( 75.0 ) Safe.

Check 5: Supported beam - Capacity at notch


Shear and bending interaction at the notch:
Basic requirement, Mnc < McN
where Mnc = Fv (t1+c)
Depth of top notch dct = 0.0 mm
Depth of bottom notch dcb = 0.0 mm
Length of notching c = 0.0 mm
Since the beam is not notched, this check is not required.

Design load Fv = 20.0 kN


Eccentricity for Fv (t1+c) = 0 mm
Moment at the notch location Mnc = 0.0 kN.m. (Indicative)
Depth of beam web at notched section Dc = 240.4 mm
Breadth of flange B2' = 101.6 mm
Area of web at notched section Aw' = tw*Dc xN = |{c - [e3+(nc-1)*g]}|
2
= 1370.3 mm
Area of flange at notched section Af' = tf2*B2 xN = 110 mm
2
= 690.9 mm
Distance of c.g. from soffit of the beam c1 = D2/2
= 127.00 mm
M.I. of the notched section I' = N.A. cm4
Extreme fibre distance ymax = 127.0 mm
3
Sectional modulus at notched section ZN = N.A. cm
Shear capacity at the notch PvN = 0.6pyAvN
= 159.89 kN
Shear at notch AvN = [et+eb+(nr-1)p] tw
= 969.00 mm2

For Low Shear (i.e. Fv <= 0.75 PvN), moment capacity of beam at the notch
in the presence of shear, McN = py Zn (Indicative)
McN = N.A. kN.m.
For High Shear (i.e. Fv > 0.75 PvN), moment capacity of beam at the notch
in the presence of shear, McN = 1.5 * py * Z * { 1 - (Fv/PvN)^2 }^0.5
= N.A. kN-m
Moment capacity of beam at the notch, in the presence of shear,
a) for single bolt line or for double bolt lines, if xN > 2d
McN = N.A. kN-m
Mnc = Fv * (t1 + c) = N.A. kN-m N.A.

b) for double bolt lines, if xN < 2d McN = N.A. kN-m


Mnc = Max [Fv * (t1 + c), Fv(t1+e3+(n-1)*g)] = N.A. kN-m N.A.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000
Check 6: Supported beam - Local stability of notched beam
For one flange notched
Basic requirement, dct < D/2 N.A.
D/tw = 44.6 c < D for D/tw < 54.3 N.A.

c < 54.3 *D for D/tw > 54.3 N.A.


3
(D/tw)
For both flanges notched
Basic requirement, Max (dct , dct ) < D/5 N.A.
D/tw = 44.6 c < D for D/tw < 54.3 N.A.

c < *D
54.3 for D/tw > 54.3 N.A.
(D/tw)3
Since the beam is not notched, this check is not required.

Check 7: Weld between fin plate and web of supporting member


Transverse Shear in weld FT = 75.0 kN Angle between FT & throat of weld,
Longitudinal Shear in weld FL = 20.0 kN q = 45 deg
Strength of weld pw = 250 M Pa
Size of weld provided s = 6 mm
Length of weld lw = (l - 2s)*2
= 316 mm
Longitudinal shear capacity, PL = pw * a* lw
= 335.1 kN
2
Transverse shear capacity, PT = K * PL where, K = 1.25*sqrt(1.5/(1+cos q))
K = 1.25
= 418.9 kN
Interaction (FL/PL)^2 + (FT / PT)^2 = 0.036 < 1 < 1 Safe.

Check 8: Supporting beam / column - Local capacity


(i) Local shear capacity of supporting member:
Basic requirement, Fv / 2 < Pv
Local shear capacity of Supporting Column web
Pv = 0.6 py Av
Av = 0.9 l tw
= 1132.2 mm2
Pv = N.A. kN > Fv / 2 ( N.A. ) N.A.
Since the beam Supported by Column Flange, this check is not required.
(ii) Punching shear capacity of supporting member:
Yielding of the fin plate occurs before punching shear failure of the supporting member.
Basic requirement, tp < tw (Usc / fb)
Maximum bending stress in the fin plate fb = Fv a / Zgross & fb py.f
Zgross = tp l 2 / 6
= 48166.7 mm3
fb = 27.0 M Pa
tw (Usc / fb) = N.A. mm > tp ( N.A. ) N.A.
Since the beam Supported by Column Flange, this check is not required.
(iii) Local shear capacity of Supporting Column web, if supporting two beams:
Basic requirement, Fv1A / 2 + Fv2 / 2 < Pv
Local shear capacity of supporting beam Pv = 0.6 py Av
web or column web Av = 0.9 l2 tw Fv1A = Fv1 l2/l1 l2 = 0
= 1132.2 mm2 Fv2 = 0 KN
Pv = N.A. kN > Fv1A / 2 + Fv2 / 2
( N.A. ) N.A.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000
Check 9: Structural integrity - Connecting elements
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - tension and bearing capacity of fin plate
(i) For tension
Basic requirement, Tie force < Tension capacity of fin plate
Tension capacity of fin plate = min (py A , Ke py Anet )
A = l f * tp
= 1700.00 mm2
Anet = A - nr*Dh*tp
= 1180.00 mm2
Effective net area coefficient Ke = 1.20
Tension capacity of fin plate = Min. { 467.50 kN, 389.40 kN }
= 389.40 kN > Tie force Safe.
(ii) For bearing ( 75.0 )
Basic requirement, Tie force < Bearing capacity of fin plate
Bearing capacity of fin plate = Min(3*nr*d*tf*pbs, n*(1.5*d*tf*pbs+0.5*e2*tf*pbs)
( for nth column of bolts) nc = 2 = 561.2 KN > Tie force Safe.
( 75.0 )
Check 10: Structural integrity - Supported member
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - tension and bearing capacity of supported member web
(i) For tension
Basic requirement, Tie force < Net Tension Capacity of beam web
Net Tension Capacity of beam web = Le * tw * pbs
Le = 2ee + (n-1)pe - nDh
nc = 2 ee = Min(e3+(nc-1)*g-Dh, et)
= 50.0 mm
pe = Min(p, 2(e3+(nc-1)*g-Dh))
= 70.00 mm
Le = 118.0 mm
Net Tension Capacity of beam web = 185.0 kN > Tie force Safe.
( 75.0 )
(ii) For bearing
Basic requirement, Tie force < Bearing capacity of beam web
Bearing capacity of beam web = Min(3nr*d*tw*pbs,n(1.5d*tw*pbs+ 0.5*e3*tw*pbs)
th
( for n column of bolts) = 319.9 kN > Tie force Safe.
( 75.0 )
Check 11: Structural integrity - Supporting member web
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - Tying capacity of supporting member web, in the presence of axial compression in the column
Basic requirement,
Tie force < Tying capacity of supporting member (Column) web
Tying capacity of supporting Column web = 8 Mu 0.5 Where, 1.5 in eqaution
{ 1 + 1.5(1-1) }
1 - 1 includes an allowance
Moment capacity of supporting Column web Mu = pu tw2 / 4 for the axial compression
per unit length in the column
Design Tensile Strength of supporting Column web pu = Us / 1.25 Supporting Member
(Floor beam)

( Design tensile strength, pu = 328 MPa 328.00 MPa tp 'tp' THK PLATE

BS EN 10025: 1993) Mu = 4490.32 N.mm/mm


dc
lp

lp

(Tie force)

= (l-2*s) / dc
= 0.51 Supporting Member

= (tp + 2s) / dc
(Floor beam)

FIN PLATE CONNECTING TO BEAM WEB

= 0.07
Tying capacity of supporting Column web = N.A. kN > Tie force N.A.
Web strengthening stiffener for the supporting member is not required. ( 75.0 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-03 BS 5950-1 :2000
Check 12: Supporting beam / column - Welds (Tying Force)
Weld between fin plate and beam web
Transverse Shear in weld FT = 75.0 kN Angle between FT & throat of weld
Longitudinal Shear in weld FL = 0.0 kN q = 45 deg
Strength of weld pw = 250 M Pa
Size of weld provided s = 6 mm
Length of weld lw = (l - 2s)*2
= 316.0 mm
Longitudinal shear capacity, PL = pw * a* lw
= 335.1 kN
Transverse shear capacity, PT = K * PL
where, K = 1.25*sqrt(1.5/(1+cos2q))
K = 1.25 = 418.9 kN
Interaction (FL/PL)^2 + (FT / PT)^2 = 0.1790 < 1 Safe

Check 13: Block Shear Capacity at the connection for Tie force

(i) For Fin Plate:


Basic requirement Tie force < Block shear capacity of fin plate
Block shear capacity of fin plate Prf = 0.6 py tp [Lt+Ke(Lv-kDh)]
Length of shear face Lv = 110 mm
Length of tension face Lt = 120 mm
Coefficient k = 2.50
Prf = 287.10 kN
Block shear capacity of fin plate Prf = 287.10 kN > Tie force Safe.
( 75.0 )
(ii) For Supported beam web:
Basic requirement Tie force < Block shear capacity of supported beam web
Block shear capacity of fin plate Prb = 0.6 py tw [Lt+Ke(Lv-kDh)]
Length of shear face Lv = 110 mm
Length of tension face Lt = 120 mm
Coefficient k = 2.50
Prb = 163.65 kN
Block shear capacity of fin plate Prb = 163.65 kN > Tie force Safe.
( 75.0 )
Check 14: Check for Supporting member web due to axial force

Tying capacity of supporting member web for axial force

Tying capacity of supporting Column web = 8 Mu 0.5 Where, 1.5 in eqaution


{ 1 + 1.5(1-1) }
1 - 1 includes an allowance
Moment capacity of supporting Column web Mu = pu tw2 / 4 for the axial compression
per unit length in the column
Design Tensile Strength of supporting Column web pu = Us / 1.25 Supporting Member

( Design tensile strength, pu = 328 MPa 328.00 MPa


(Floor beam)

tp 'tp' THK PLATE

BS EN 10025: 1993) Mu = 4490.32 N.mm/mm


dc
lp

lp

(Tie force)

= (l-2*s) / dc
= 0.55 Supporting Member
(Floor beam)

= (tp + 2s) / dc FIN PLATE CONNECTING TO BEAM WEB

= 0.07
Tying capacity of supporting Column web = N.A. kN > Axial force N.A.
Web strengthening stiffener for the supporting member is not required. ( 75.0 )

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 403 318 217:1.2DL+1.2L 471.980 7.337 -1.076 -0.000 0.000 0.000
Min Fx 403 318 218:1.2DL+1.2L -471.841 7.337 1.561 -0.000 0.000 0.000
Max Fy 452 331 202:1.4DD+1.4 -2.239 13.648 0.257 0.001 0.000 0.000
Min Fy 534 313 202:1.4DD+1.4 -0.290 -16.098 0.032 0.032 -0.000 -0.000
Max Fz 405 323 218:1.2DL+1.2L 94.551 1.200 51.702 -0.011 -36.976 -0.028
Min Fz 405 323 217:1.2DL+1.2L -93.685 1.194 -52.245 -0.015 37.483 -0.013
Max Mx 513 344 211:1.2DL+1.2L -1.315 0.197 -0.000 0.055 0.000 0.000
Min Mx 350 312 209:DL+1.4WL 0.087 1.591 0.050 -0.044 0.000 0.000
Max My 405 323 217:1.2DL+1.2L -93.685 1.194 -52.245 -0.015 37.483 -0.013
Min My 405 323 218:1.2DL+1.2L 94.551 1.200 51.702 -0.011 -36.976 -0.028
Max Mz 505 205 8:WL +Z PRES -0.950 -0.339 0.040 0.010 0.034 0.292
Min Mz 491 185 202:1.4DD+1.4 -1.615 -10.323 0.287 0.001 -0.297 -12.393

Y
X
Z Load 1

Whole Structure
Jun 29, 2017
SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN
(FLEXIBLE SUPPORT CONNECTION)
Connection Identification - D-02
INPUT DATA TO BE PROVIDED :
Supporting Member UB 356x171x51 Column Flange
D = 355.0 mm r = 10.2 mm Weight = 51.0 kG/m
B = 171.5 mm D' = 311.6 mm
tw = 7.4 mm A = 64.9 cm2
Tf = 11.5 mm
Supported Member UB 356x171x51 Beam Web (Rolled Section)
D = 355.0 mm r = 10.2 mm Weight = 51.0 kG/m
B = 171.5 mm D' = 311.6 mm
tw = 7.4 mm A = 64.9 cm2
Tf = 11.5 mm

Member end actions


Factored Axial Forces
Compression = 480 kN Tension = 480 kN Vertical Shear Fv1 = 25 kN
Factored Tying Forces Vertical Shear Fv2 = 0 kN
Compression = 75 kN Tension = 75 kN
Connection Web of supported member
Grade of bolts = Gr. 8.8
Type of Connection >> Bearing Connections = Non-Preloaded Bolts

Shear Strength of Bolt (Table.30, BS5950-1:2000) ps = 375 M Pa

Tensile Strength of Bolt (Table.34, BS5950-1:2000) pt = 560 M Pa


Design Strength of Weld pw = 250 M Pa
Grade of material -Member = S 275 M Pa Plate = S 275 M Pa
Minimum Tensile Strength -Member Us.b = 410 M Pa Plate Us.f = 410 M Pa
Minimum Yield Strength (Supported) Ys.b = 275 M Pa Fin Plate Ys.f = 275 M Pa
(Design Strength, py = 1.0Ys < Us/1.2) (Supporting) Ys.b = 265 M Pa Rein. Plate Ys.f = 275 M Pa
Bearing Strength -Member pbs.b = 460 M Pa Plate pbs.f = 460 M Pa
Diameter of bolt d = 24 mm
Diameter of bolt hole Dh = 26 mm
Nr of bolt columns nc = 2
Nr of bolt rows nr = 4
Spacing of bolt rows (pitch) p = 80 mm
Spacing of bolt columns (gauge) g = 80 mm
Horizontal Edge distance for plate e2 = 40 mm
Vertical End distance in plate at top e1 = 40 mm
Vertical End distance in plate at bottom e1.1 = 40 mm
Vertical End distance in member at top et = 40 mm
Vertical End distance in member at bottom eb = 40 mm
Horizontal Edge distance for member e3 = 40 mm
Distance between face of supporting member & supported beam (End Projection) t1 = 15 mm
Thickness of fin plate tp' = 12 mm
Thickness of reinforcement plate (doubler plate) twrp = 6 mm
Nr of shear planes Ns = 1
2 2
Sum of square of 'r' for the bolt group r = 76,800 mm

Minimum Shank Tension P0 = N.A. kN


Hole Factor for Standard Size Holes kbs = 1
Slip factor for Class A m = N.A.
Leg length of the fillet weld s = 8 mm
Hole Factor for Standard Size Holes (For Axial force) kbs = 1
Lenght of fin plate, l = 320.0 mm Depth of top notch dct = 0 mm
Width of fin plate, Bf = 175.0 mm Depth of bottom notch dcb = 0 mm
Thickness of fin plate, tp = 12.0 mm Effective Net Area Co-efficient Ke = 1.2 (For Plate)
TOS to first bolt hole = 65.0 mm Ke = 1.2 (For Section)
Fin Plate Type = Extended:Stiffened
Jun 29, 2017
SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN

D-02 00

0.701 Web strengthening stiffener for the supporting member is not required.
Safe. Bearing capacity per bolt Pbs = 110.40 kN > Fs ( 67.14 )
0.608 (Bearing of bolts on the fin plate and beam web)
Safe. Shear Capacity per bolt Ps = 132.32 kN > Fs ( 67.14 )
0.507
Safe. Shear capacity of fin plate Pv.min = 510.05 kN > Fv ( 25.00 )
0.049
Safe. Moment capacity of fin plate Mc = 56.3 kN.m > Fv a ( 3.43 )
0.061 (Shear and bending interaction)
N.A. Lateral Torsional buckling resistance = N.A. kN.m > Fv a ( N.A. )
moment of fin plate Short fin plate, This check is not required
Safe. Tension capacity of fin plate = 685 kN >T ( 480.00 )
0.701
Safe. Compression Capacity of fin plate = 1189 kN >C ( 480.00 )
0.404
Safe. Shear capacity of the beam at Pv.min = 668.61 kN > Fv ( 25.00 )
0.037 the connection
N.A. Moment capacity of the notched beam = N.A. kN.m > Mnc ( N.A. )
th
(Shear and bending interaction at n col. of bolts) Since the beam is not notched, this check is not required.
N.A. Moment capacity of the beam web = N.A. kN.m > Fv{ a+(nc-1)*g} ( N.A. )
(Shear and bending interaction of the beam web) Short fin plate, This check is not required
Safe. Tension capacity of Supported beam = 765 kN >T ( 480.00 )
0.627
N.A. Moment capacity of beam at the notch = N.A. kN.m < McN ( N.A. )
in the presence of shear Since the beam is not notched, this check is not required.
N.A. Local stability of notched beam Since the beam is not notched, this check is not required.
Safe. Weld connecting fin plate to supporting = 0.200 < 1 ( 8.00 mm)
0.200 beam / column (Utilization ratio)
N.A. Local shear capacity of supporting beam = N.A. kN > Fv/2 ( N.A. )
Since the beam Supported by Column Flange, this check is not required.
N.A. Punching shear capacity of supporting beam = N.A. mm > tp ( N.A. )
Since the beam Supported by Column Flange, this check is not required.
N.A. Local shear capacity of supporting beam = N.A. kN > Fv1A/2+Fv2/2 ( N.A. )
web or column web supporting two beams:
Recommended detailing practice is satisfied.
Structural Integrity Checks (For Tying Force)
These checks are only needed if it is necessary to comply with structural integrity requirements.
Safe Weld connecting fin plate to supporting = 0.070 < 1 ( 8.00 mm)
0.070 beam / column (Utilization ratio)
Safe. Tension capacity of fin plate = 796.0 kN > Tie Force ( 75.00 )
0.094
Safe. Bearing capacity of fin plate = 1236.5 kN > Tie Force ( 75.00 )
0.061
Safe. Tension capacity of beam web = 796.0 kN > Tie Force ( 75.00 )
0.094
Safe. Bearing capacity of beam web = 1380.7 kN > Tie Force ( 75.00 )
0.054
N.A. Tying capacity of web of supporting member = N.A. kN > Tie Force ( 75.00 )
Web strengthening stiffener for the supporting member is not required.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000

SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN

Connection identification D-02

Supporting member D1 = 355.0 mm tw1 = 7.4 mm r1 = 10.2 mm


(Beam / Column) B1 = 171.5 mm Tf1 = 11.5 mm D'1 = 311.6 mm
UB 356x171x51 A1 = 64.9 cm2

Supported Beam D2 = 355.0 mm tw2 = 7.4 mm r2 = 10.2 mm


UB 356x171x51 B2 = 171.5 mm Tf2 = 11.5 mm D'2 = 311.6 mm
A2 = 64.9 cm2
Member End Actions
Factored
Compressive force C = 480.0 kN
Tensile force T = 480.0 kN
Vertical Shear force Fv = 25.0 kN
Tying force Tf = 75.0 kN
Web connection
Connection details
Grade of bolt = Gr. 8.8 Bearing Connections
Grade of material Rolled sections = S 275 Plates - S 275
Minimum Tensile Strength Us.b = 410.0 M Pa Us.f = 410.0 M Pa
Minimum Yield Strength = Design strength Supported beam: py.b = 275.0 M Pa Fin Plate: py.f = 275.0 M Pa
Minimum Yield Strength = Design strength Supporting beam: py.b = 265.0 M Pa Reinforcement p py.f = 275.0 M Pa
Bearing Strength pbs.b = 460.0 M Pa pbs.f = 460.0 M Pa
Shear Strength of Bolt ps = 375.0 M Pa
Tensile Strength of Bolt pt = 560.0 M Pa
Bearing Strength of bolt pbb = 1000.0 M Pa
Minimum Shank Tension Po = N.A. kN
Design Strength of Weld pw = 250.0 M Pa
Diameter of bolt d = 24.0 mm
Diameter of bolt hole Dh = 26.0 mm
Area of one nominal bolt Ab = 452.4 mm2
Effective area of one bolt At = 352.9 mm2
Nr of bolt column nc = 2
Nr of bolt rows nr = 4
Nr of bolts n = 8
Spacing of bolt rows (pitch) p = 80.0 mm
Spacing of bolt coumns (gauge) g = 80.0 mm
Horizontal Edge distance for member e3 = 40.0 mm
Horizontal Edge distance for plate e2 = 40.0 mm
Vertical End distance in plate at top e1 = 40.0 mm
Vertical End distance in plate at bottom e1.1 = 40.0 mm
Vertical End distance in member at top et = 40.0 mm
Vertical End distance in member at bottom eb = 40.0 mm
Dist. between face of supporting mem. & supported beam t1 = 15.0 mm (End Projection)
Length of fin plate lf = 320.0 mm
Width of fin plate Bf = 175.0 mm
Thickness of fin plate tp = 12.0 mm ( 1 - 12 mm plate )
Thickness of reinforcement twrp = 6.0 mm
Total thickness of web tw = 13.4 mm
Least thickness of connected parts t = 12.0 mm
Nr of shear planes Ns = 1
Sum of square of 'r' for the bolt group r
2
= 76800.0 mm2
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000
Check 1 : Recommended detailing practice
Length of fin plate l = 40 + (3 * 80 )+ 40 >= 0.6D2
(To give adequate "nominal torsional restraint" = 320.0 mm ( 213.0 ) Safe.
BS 5950-1 Table 13 and cl.4.2.2)
Spacing of Bolts
Minimum spacing of bolts = 2.5 d <= Min.(p,g)
= 60.0 mm ( 80.0 ) Safe.
Maximum spacing of bolts = 14 t > Max.(p,g)
= 168.0 mm ( 80.0 ) Safe.
End & Edge Distances of Bolts
Minimum end and edge distances of bolts = 1.25 Dh <= Min.(e1, e1.1, e2,e3, et, eb)
= 32.5 mm ( 40.0 ) Safe.
Maximum end and edge distances of bolts = 11 t > Max.(e1, e1.1, e2,e3)
= 132.0 mm ( 40.0 ) Safe.
Type of fin plate based on the length, tp / a = 0.218 >= 0.15, Short fin plate
Recommended detailing practice is satisfied.
Check 2: Supported beam - Bolt Group
Basic Requirement ( Bearing of bolts on fin plate and beam web)
Fs < Pbs
Vertical Reaction Fv = 25.0 kN
Eccentricity of FV about c.g. of bolt group e = 0.5*(B1-tw1)+ t1+e3+0.5
For shear connection
= 177.1 mm
Moment due to eccentricity M = FV*e e = 177.05
= 4.43 kN.m
2 2
Distance of outermost bolt from cg of bolt group r = Sqrt(((nc-1)*g/2) +((nr-1)*p/2) )
= 126.5 mm
2 2
Sum of square of 'r' for all bolts r = 76,800.0 mm
Vertical force on a bolt due Fsv = Fv/n
to direct shear = 3.13 kN
Horizontal force on a bolt due Fah = Max (C , T)/n
to Axial Force = max(480 , 480) /8
= 60.00 kN
2
Maximum shear in bolt due to M Fm = Me*r/Er
= 7.29 kN
Vertical force on the outermost bolt Fsmv = Fm * cosq q = 71.57
due to moment M, = 2.31 kN
Horizontal force on the outermost bolt Fsmh = Fm * sinq
due to moment M, = 6.92 kN
Total vertical force on a bolt Fvb = Fsv + Fsmv
= 5.43 kN
Total horizontal force on a bolt Fhb = Fah + Fsmh
= 66.92 kN
Resultant force on outermost bolt Fs = Sqrt (Fvb2 + Fhb2)
= 67.14 kN

Bearing Capacity per bolt Pbs = Min. (Pbs.f , Pbs.b ) (Indicative)


Bearing Strength of the plate per bolt Pbs.f = kbs*d*tp*pbs.f < 0.5 * kbs*min.(e1, e1.1,e2)*tp*pbs.f
= 110.40 kN where, kbs = 1.0
for Standard Size Holes
Bearing Strength of the web per bolt Pbs.b = kbs*d*tw*pbs.b < 0.5 * kbs*min.(et, eb,e3)*tw*pbs.b
= 123.28 kN where, kbs = 1.0
for Standard Size Holes
Bearing Capacity per bolt Pbs = 110.40 kN > Fs Safe.
( 67.1 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000
Shear Capacity per bolt Ps = Min. (Ps1 & Ps2 below)
1.0 Shear capacity per bolt with no reductions Ps1 = ps * As * Ns where, As = At
= 132.3 kN
2.0 Shear capacity per bolt with reduction for large grip length
(if total thickness of connected plies, Tg > 5d) Ps = ps * As * Ns * { 8d / (3d+Tg)}
where, Tg = 25.4 mm & 5d = 120.0 mm. = 132.3 * 1.97
Ps2 = N.A. kN ( Tg<5d)
3.0 Shear capacity reduction for Long Joint Ps = ps * As * Ns * { 5500-Lj / 5000}
Lj = 240 mm 132.3 * 1.05 ( Lj<500)
Ps3 N.A. kN
Shear Capacity per bolt Ps = 132.3 kN > Fs Safe.
( 67.1 )
Connection designed to be Non-Slip under factored loads
Slip resistance of one bolt PSL = N.A.
= N.A.
Slip factor m = N.A.
Minimum Shank Tension Po = N.A.
PSL = N.A.
Shear Capacity per bolt Pb = 132.3 kN > Fs Safe.
( 67.1 )

Check 3: Supported beam - Connecting elements


Shear and bending capacity of fin plate connected to supported beam
(i) For Shear:
Basic requirement, Fv < Pv.min
Shear capacity of fin plate Pv.min = Min.{Plain shear capacity (Pv) , Block shear capacity (Pr1)}
Plain shear capacity of fin plate Pv = Min. (0.6pyAv , 0.7pyKe Av.net)
Shear Area Av = 0.9 [e1+e1.1+(nr-1)p] tp
= 3456.00 mm2
Net Shear Area after deducting holes Av.net = Av - nr*Dh*tp
= 2208.00 mm2
Effective net area coefficient Ke = 1.20
Plain shear capacity of fin plate Pv = Min. { 570.24 kN, 510.05 kN }
= 510.05 kN
Block shear capacity of fin plate Pr1 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 280.00 mm
Length of tension face Lt = 120.00 mm
Coefficient k = 2.50
Pr1 = 685.08 kN Pr1
Block shear capacity of fin plate Pr = Pr1 = 685.08 kN
Shear capacity of fin plate Pv.min = 510.05 kN > Fv Safe.
( 25.0 )
(ii) Shear and bending interaction
Basic requirement, Fv a < Mc
For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of fin plate Fv <= 0.75 Pv.min
Mc = py * tp (e1+e1.1+(nr-1)p)2 Low Shear
*
6
= 56.32 kN-m
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of fin plate
Mc = py * tp * (e1+e1.1+(nr-1)p)2 * { 1 - (Fv/Pv.min)^2 }1/2
6
= N.A. kN-m
Moment capacity of fin plate Mc = 56.32 kN-m > Fv a Safe.
( 3.4 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000

(iii) Lateral torsional buckling resistance of long fin plates * This check is not required for short fin plate

Basic requirement, Fv a < Mb / mLT &


Fv a < py Zx
Lateral torsional buckling moment of resistance of fin plate,
Mb = pb Z x
Elastic modulus of fin plate about major axis Zx = tp * l 2
6
Zx = 204,800.0 mm3
LT = 2.8 * { Lel / 1.5tp2}^1/2 (cl. B.2.7, BS5950-1:2000)
Le = 1 a
Le = 55.00 mm
LT = 25.27
mLT = 0.60 (Table 18 of BS5950-1 2000)
pE * py
Bending strength of fin plate pb = 2
LT + (LT -pEpy )^0.5

E / LT2
2
pE =
= 3167.22 M Pa
LT = [py + ( LT+1) pE] / 2
Robertson constant LT = 7.00 (Cl. B.2.2 of BS5950-1 2000)
Limiting slenderness ratio Lo = 0.4 (2 E / py )^0.5
= 34.31
Perry factor LT = 0.00
LT = 1721.11 M Pa
Bending strength of fin plate pb = 275.00 M Pa
Lateral torsional buckling resistance Mb = pb Z x
moment of fin plate = N.A. kN-m
Mb / mLT = N.A. kN-m > Fv a N.A.
( N.A. )
py Zx = N.A. kN-m > Fv a N.A.

(iv) Tension Capacity


Basic requirement, T < Min ( Ptf, Prf)
Tensile capacity of fin plate Ptf = py*Aeff
Aeff = Ke*An < Ag
An = (l-nr*Dh)*tp
= 2592 mm2
Ke = 1.2
Aeff = 3110.4 mm2
= 855 kN

Block Shear Capacity of Fin plate Prf = Min(Pr1, Pr2)


Pr2 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 240 mm
Length of tension face Lt-kDh = 162 mm
Pr2 = 860 kN Pr1 Pr2

Block Shear Capacity of Fin plate Prf = 685 kN (Indicative)

Tension Capacity of fin plate = 685 kN > T


(Tension Yielding & Block Shear) ( 480.0 ) Safe.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000
(v) Compression Capacity
Basic requirement, C < Pcf
Compression Capacity of fin plate Pc = pc*Ag
Area of fin plate Ag = l *tp
2
= 3840 mm
Unsupported length L = t1+e3+((B1-tw1)/2)
= 137.05 mm
Effective Length Leff = 1.2L
= 164 mm Table 24 for Curve 'b' in BS:5950:1:2000
Radius of gyration rmin = t/sqrt(12) Py = 275
= 3.46 mm
Slenderness ratio = Leff/rmin pc
= 47.5 72.00 236.00
Width of fin plate (Whitmore section of 30 deg) w = 92.4 47.5 309.57
Compressive stress area = 3840 mm2 74.00 230.00
(Min of Ag & Awhitmore)
Pcf = 1189 kN > C
( 480.0 ) Safe.

Check 4: Supported beam - Capacity at the connection


Shear and bending capacity of supported beam
(i) For Shear:
Basic requirement, Fv < Pv.min
Shear capacity of the beam at the connection Pv.min = Min (Pv, Pr1)
Plain shear capacity of beam Pv = Min. (0.6pyAv , 0.7pyKe Av.net)
Shear Area Av = (et+eb+(nr-1)*p)*tw
= 4288.00 mm2
Net Shear Area after deducting holes Av.net = Av - nr*Dh*tw
= 2894.40 mm2
Effective net area coefficient Ke = 1.20
Plain shear capacity of beam Pv = Min. { 707.52 kN, 668.61 kN }
= 668.61 kN
Block shear capacity of beam Pr1 = 0.6 py tw [Lv+Ke(Lt-kDh)]
(Applicable to notched beams only)
Length of shear face Lv = 280.00 mm
Length of tension face Lt = 120.00 mm
Coefficient k = 2.50
Block shear capacity of beam Pr1 = 765.01 kN (Indicative)

Shear capacity of the beam at the connection, Pv.min = 668.61 kN > Fv Safe.
( 25.0 )

(ii) Shear and bending interaction at the nth column line of bolts, if the notch length c > (e3+g)

Basic requirement, Mnc < McC


where Mnc = Fv (t1+e3+(nc-1)*g)
Depth of top notch dct = 0.0 mm
Depth of bottom notch dcb = 0.0 mm
Length of notching c = 0.0 mm No Notching. This check is not required.
Since the beam is not notched, this check is not required.
Design load Fv = 25.0 kN
Eccentricity for Fv (t1+e3+(nc-1)*g) = 0 mm
th
Moment at the n column line of bolts Mnc = 0.0 kN.m.
Depth of beam web at notched section Dc = 332.0 mm
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000
Breadth of flange B2'
= 171.5 mm
Area of web at notched section Aw'
= tw*Dc
= 4448.8 mm2
Area of flange at notched section Af' = tf2*B2
= 1972.3 mm2
Distance of c.g. from soffit of the beam c1 = D2/2
= 177.50 mm
M.I. of the notched section I' = N.A. cm4
Extreme fibre distance ymax = 177.5 mm
3
Sectional modulus at notched section Z = N.A. cm
For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of the notched beam
at the connection in the presence of shear, McC = py Z
McC = N.A. kN.m.
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of the notched beam
at the connection in the presence of shear, McC = 1.5 * py * Z * { 1 - (Fv/Pv.min)^2 }^0.5
= N.A. kN-m
Moment capacity of the notched beam at the connection in the presence of shear,
McC = N.A. kN-m > Mnc N.A.
( N.A. )

(iii) Shear and bending interaction of the beam web section - Long fin plates only * This check is not required for short fin plate

Basic requirement, Fv { a+ (nc-1)*g} < McBC + PVAB (nr-1)p

For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of the beam web BC
Mc BC = py tw [(nr-1)p]2
6
= 35.38 kN-m
Shear capacity of the beam web AB Pv AB = Min {( 0.6 py (e3+(nc-1)g)tw),
(0.7pyKe(e3+(nc-1)g+0.5Dh-ncDh)tw)}
= Min. { 265 kN , 250.73 kN }
Pv AB = 250.73 kN
Shear capacity of the beam web BC Pv BC = Min {( 0.6 py (nr-1)p)tw),
(0.7pyKe((nr-1)p+Dh-nrDh)tw)}
= Min. { 530.64 kN , 501.45 kN }
Pv BC = 501.45 kN
Shear force on the beam web BC Fv BC = Fv - (Pv - PVBC ) but > 0
= 0.00 kN
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of the beam web BC
py tw [(nr-1)p]2
Mc BC = * {1-(FvBC/PvBC)2}^0.5
4
= N.A. kN-m
Moment capacity of the beam web BC Mc BC = N.A. kN-m
McBC + PVAB (nr-1)p = N.A. kN-m > Fv { a+ (nc-1)*g}
( N.A. ) N.A.
(iv) Tension Capacity
Basic requirement, T < Ptb
Net Tension Capacity of supported beam = Le * tw * pbs
Le = 2ee + (n-1)pe - nDh
ee = Min(e3+(nc-1)*g-Dh, et)
= 40.0 mm
pe = Min(p, 2(e3+(nc-1)*g-Dh))
= 80.00 mm
Le = 216.0 mm
Net Tension Capacity of beam web = 796.0 kN
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000

Block Shear Capacity of Supported beam Prb = Min(Pr1, Pr2)


Pr2 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 240 mm
Length of tension face Lt-kDh = 162 mm
Pr2 = 960 kN Pr1 Pr2
Block Shear Capacity of Fin plate Prf = 765 kN (Indicative)

Tension Capacity of supported beam = 765 kN > T


(Tension Yielding & Block Shear) ( 480.0 ) Safe.

Check 5: Supported beam - Capacity at notch


Shear and bending interaction at the notch:
Basic requirement, Mnc < McN
where Mnc = Fv (t1+c)
Depth of top notch dct = 0.0 mm
Depth of bottom notch dcb = 0.0 mm
Length of notching c = 0.0 mm
Since the beam is not notched, this check is not required.

Design load Fv = 25.0 kN


Eccentricity for Fv (t1+c) = 0 mm
Moment at the notch location Mnc = 0.0 kN.m. (Indicative)
Depth of beam web at notched section Dc = 332.0 mm
Breadth of flange B2' = 171.5 mm
Area of web at notched section Aw' = tw*Dc xN = |{c - [e3+(nc-1)*g]}|
2
= 4448.8 mm
Area of flange at notched section Af' = tf2*B2 xN = 120 mm
2
= 1972.3 mm
Distance of c.g. from soffit of the beam c1 = D2/2
= 177.50 mm
M.I. of the notched section I' = N.A. cm4
Extreme fibre distance ymax = 177.5 mm
3
Sectional modulus at notched section ZN = N.A. cm
Shear capacity at the notch PvN = 0.6pyAvN
= 707.52 kN
Shear at notch AvN = [et+eb+(nr-1)p] tw
= 4288.00 mm2

For Low Shear (i.e. Fv <= 0.75 PvN), moment capacity of beam at the notch
in the presence of shear, McN = py Zn (Indicative)
McN = N.A. kN.m.
For High Shear (i.e. Fv > 0.75 PvN), moment capacity of beam at the notch
in the presence of shear, McN = 1.5 * py * Z * { 1 - (Fv/PvN)^2 }^0.5
= N.A. kN-m
Moment capacity of beam at the notch, in the presence of shear,
a) for single bolt line or for double bolt lines, if xN > 2d
McN = N.A. kN-m
Mnc = Fv * (t1 + c) = N.A. kN-m N.A.

b) for double bolt lines, if xN < 2d McN = N.A. kN-m


Mnc = Max [Fv * (t1 + c), Fv(t1+e3+(n-1)*g)] = N.A. kN-m N.A.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000
Check 6: Supported beam - Local stability of notched beam
For one flange notched
Basic requirement, dct < D/2 N.A.
D/tw = 26.5 c < D for D/tw < 54.3 N.A.

c < 54.3 *D for D/tw > 54.3 N.A.


3
(D/tw)
For both flanges notched
Basic requirement, Max (dct , dct ) < D/5 N.A.
D/tw = 26.5 c < D for D/tw < 54.3 N.A.

c < *D
54.3 for D/tw > 54.3 N.A.
(D/tw)3
Since the beam is not notched, this check is not required.

Check 7: Weld between fin plate and web of supporting member


Transverse Shear in weld FT = 480.0 kN Angle between FT & throat of weld,
Longitudinal Shear in weld FL = 25.0 kN q = 45 deg
Strength of weld pw = 250 M Pa
Size of weld provided s = 8 mm
Length of weld lw = (l - 2s)*2
= 608 mm
Longitudinal shear capacity, PL = pw * a* lw
= 859.7 kN
2
Transverse shear capacity, PT = K * PL where, K = 1.25*sqrt(1.5/(1+cos q))
K = 1.25
= 1074.6 kN
Interaction (FL/PL)^2 + (FT / PT)^2 = 0.200 < 1 < 1 Safe.

Check 8: Supporting beam / column - Local capacity


(i) Local shear capacity of supporting member:
Basic requirement, Fv / 2 < Pv
Local shear capacity of Supporting Column web
Pv = 0.6 py Av
Av = 0.9 l tw
= 2131.2 mm2
Pv = N.A. kN > Fv / 2 ( N.A. ) N.A.
Since the beam Supported by Column Flange, this check is not required.
(ii) Punching shear capacity of supporting member:
Yielding of the fin plate occurs before punching shear failure of the supporting member.
Basic requirement, tp < tw (Usc / fb)
Maximum bending stress in the fin plate fb = Fv a / Zgross & fb py.f
Zgross = tp l 2 / 6
= 204800.0 mm3
fb = 6.7 M Pa
tw (Usc / fb) = N.A. mm > tp ( N.A. ) N.A.
Since the beam Supported by Column Flange, this check is not required.
(iii) Local shear capacity of Supporting Column web, if supporting two beams:
Basic requirement, Fv1A / 2 + Fv2 / 2 < Pv
Local shear capacity of supporting beam Pv = 0.6 py Av
web or column web Av = 0.9 l2 tw Fv1A = Fv1 l2/l1 l2 = 0
= 2131.2 mm2 Fv2 = 0 KN
Pv = N.A. kN > Fv1A / 2 + Fv2 / 2
( N.A. ) N.A.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000
Check 9: Structural integrity - Connecting elements
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - tension and bearing capacity of fin plate
(i) For tension
Basic requirement, Tie force < Tension capacity of fin plate
Tension capacity of fin plate = min (py A , Ke py Anet )
A = l f * tp
= 3840.00 mm2
Anet = A - nr*Dh*tp
= 2592.00 mm2
Effective net area coefficient Ke = 1.20
Tension capacity of fin plate = Min. { 1056.00 kN, 855.36 kN }
= 855.36 kN > Tie force Safe.
(ii) For bearing ( 75.0 )
Basic requirement, Tie force < Bearing capacity of fin plate
Bearing capacity of fin plate = Min(3*nr*d*tf*pbs, n*(1.5*d*tf*pbs+0.5*e2*tf*pbs)
( for nth column of bolts) nc = 2 = 1236.48 KN > Tie force Safe.
( 75.0 )
Check 10: Structural integrity - Supported member
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - tension and bearing capacity of supported member web
(i) For tension
Basic requirement, Tie force < Net Tension Capacity of beam web
Net Tension Capacity of beam web = Le * tw * pbs
Le = 2ee + (n-1)pe - nDh
nc = 2 ee = Min(e3+(nc-1)*g-Dh, et)
= 40.0 mm
pe = Min(p, 2(e3+(nc-1)*g-Dh))
= 80.00 mm
Le = 216.0 mm
Net Tension Capacity of beam web = 796.0 kN > Tie force Safe.
( 75.0 )
(ii) For bearing
Basic requirement, Tie force < Bearing capacity of beam web
Bearing capacity of beam web = Min(3nr*d*tw*pbs,n(1.5d*tw*pbs+ 0.5*e3*tw*pbs)
th
( for n column of bolts) = 1,380.7 kN > Tie force Safe.
( 75.0 )
Check 11: Structural integrity - Supporting member web
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - Tying capacity of supporting member web, in the presence of axial compression in the column
Basic requirement,
Tie force < Tying capacity of supporting member (Column) web
Tying capacity of supporting Column web = 8 Mu 0.5 Where, 1.5 in eqaution
{ 1 + 1.5(1-1) }
1 - 1 includes an allowance
Moment capacity of supporting Column web Mu = pu tw2 / 4 for the axial compression
per unit length in the column
Design Tensile Strength of supporting Column web pu = Us / 1.25 Supporting Member
(Floor beam)

( Design tensile strength, pu = 328 MPa 328.00 MPa tp 'tp' THK PLATE

BS EN 10025: 1993) Mu = 4490.32 N.mm/mm


dc
lp

lp

(Tie force)

= (l-2*s) / dc
= 0.98 Supporting Member

= (tp + 2s) / dc
(Floor beam)

FIN PLATE CONNECTING TO BEAM WEB

= 0.09
Tying capacity of supporting Column web = N.A. kN > Tie force N.A.
Web strengthening stiffener for the supporting member is not required. ( 75.0 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-02 BS 5950-1 :2000
Check 12: Supporting beam / column - Welds (Tying Force)
Weld between fin plate and beam web
Transverse Shear in weld FT = 75.0 kN Angle between FT & throat of weld
Longitudinal Shear in weld FL = 0.0 kN q = 45 deg
Strength of weld pw = 250 M Pa
Size of weld provided s = 8 mm
Length of weld lw = (l - 2s)*2
= 608.0 mm
Longitudinal shear capacity, PL = pw * a* lw
= 859.7 kN
Transverse shear capacity, PT = K * PL
where, K = 1.25*sqrt(1.5/(1+cos2q))
K = 1.25 = 1074.6 kN
Interaction (FL/PL)^2 + (FT / PT)^2 = 0.0698 < 1 Safe

Check 13: Block Shear Capacity at the connection for Tie force

(i) For Fin Plate:


Basic requirement Tie force < Block shear capacity of fin plate
Block shear capacity of fin plate Prf = 0.6 py tp [Lt+Ke(Lv-kDh)]
Length of shear face Lv = 120 mm
Length of tension face Lt = 280 mm
Coefficient k = 2.50
Prf = 685.08 kN
Block shear capacity of fin plate Prf = 685.08 kN > Tie force Safe.
( 75.0 )
(ii) For Supported beam web:
Basic requirement Tie force < Block shear capacity of supported beam web
Block shear capacity of fin plate Prb = 0.6 py tw [Lt+Ke(Lv-kDh)]
Length of shear face Lv = 120 mm
Length of tension face Lt = 280 mm
Coefficient k = 2.50
Prb = 765.01 kN
Block shear capacity of fin plate Prb = 765.01 kN > Tie force Safe.
( 75.0 )
Check 14: Check for Supporting member web due to axial force

Tying capacity of supporting member web for axial force

Tying capacity of supporting Column web = 8 Mu 0.5 Where, 1.5 in eqaution


{ 1 + 1.5(1-1) }
1 - 1 includes an allowance
Moment capacity of supporting Column web Mu = pu tw2 / 4 for the axial compression
per unit length in the column
Design Tensile Strength of supporting Column web pu = Us / 1.25 Supporting Member

( Design tensile strength, pu = 328 MPa 328.00 MPa


(Floor beam)

tp 'tp' THK PLATE

BS EN 10025: 1993) Mu = 4490.32 N.mm/mm


dc
lp

lp

(Tie force)

= (l-2*s) / dc
= 1.03 Supporting Member
(Floor beam)

= (tp + 2s) / dc FIN PLATE CONNECTING TO BEAM WEB

= 0.09
Tying capacity of supporting Column web = N.A. kN > Axial force N.A.
Web strengthening stiffener for the supporting member is not required. ( 480.0 )

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 361 315 217:1.2DL+1.2L 60.235 -16.892 -6.287 -0.019 3.772 -10.565
Min Fx 361 315 218:1.2DL+1.2L -62.126 -16.893 6.442 -0.020 -3.865 -10.565
Max Fy 361 115 207:DL+1.4WL -3.190 45.141 -1.196 0.042 -0.000 -0.000
Min Fy 151 114 207:DL+1.4WL -3.127 -45.020 0.091 0.042 0.000 0.000
Max Fz 151 114 218:1.2DL+1.2L -60.848 18.489 21.832 -0.020 0.000 0.000
Min Fz 151 114 217:1.2DL+1.2L 59.008 18.489 -21.447 -0.019 0.000 0.000
Max Mx 510 115 202:1.4DD+1.4 -0.599 1.192 -0.000 0.339 0.000 0.000
Min Mx 510 115 8:WL +Z PRES 0.380 -3.377 0.000 -0.178 0.000 0.000
Max My 151 313 218:1.2DL+1.2L -60.848 17.057 21.832 -0.020 13.099 -10.664
Min My 151 313 217:1.2DL+1.2L 59.008 17.056 -21.447 -0.019 -12.868 -10.664
Max Mz 361 315 207:DL+1.4WL -3.190 36.782 -1.196 0.042 0.717 24.577
Min Mz 151 313 202:1.4DD+1.4 -1.428 29.418 0.299 -0.035 0.180 -18.366

Y
X
Z Load 101

Whole Structure
Jun 29, 2017
SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN
(FLEXIBLE SUPPORT CONNECTION)
Connection Identification - D-01
INPUT DATA TO BE PROVIDED :
Supporting Member UB 356x171x51 Column Flange
D = 355.0 mm r = 10.2 mm Weight = 51.0 kG/m
B = 171.5 mm D' = 311.6 mm
tw = 7.4 mm A = 64.9 cm2
Tf = 11.5 mm
Supported Member UB 533x210x101 Beam Web (Rolled Section)
D = 536.7 mm r = 12.7 mm Weight = 101.0 kG/m
B = 210.0 mm D' = 476.5 mm
tw = 10.8 mm A = 129.0 cm2
Tf = 17.4 mm

Member end actions


Factored Axial Forces
Compression = 70 kN Tension = 70 kN Vertical Shear Fv1 = 50 kN
Factored Tying Forces Vertical Shear Fv2 = 0 kN
Compression = 75 kN Tension = 75 kN
Connection Web of supported member
Grade of bolts = Gr. 8.8
Type of Connection >> Bearing Connections = Non-Preloaded Bolts

Shear Strength of Bolt (Table.30, BS5950-1:2000) ps = 375 M Pa

Tensile Strength of Bolt (Table.34, BS5950-1:2000) pt = 560 M Pa


Design Strength of Weld pw = 250 M Pa
Grade of material -Member = S 275 M Pa Plate = S 275 M Pa
Minimum Tensile Strength -Member Us.b = 410 M Pa Plate Us.f = 410 M Pa
Minimum Yield Strength (Supported) Ys.b = 275 M Pa Fin Plate Ys.f = 275 M Pa
(Design Strength, py = 1.0Ys < Us/1.2) (Supporting) Ys.b = 265 M Pa Rein. Plate Ys.f = N.A. M Pa
Bearing Strength -Member pbs.b = 460 M Pa Plate pbs.f = 460 M Pa
Diameter of bolt d = 24 mm
Diameter of bolt hole Dh = 26 mm
Nr of bolt columns nc = 1
Nr of bolt rows nr = 3
Spacing of bolt rows (pitch) p = 100 mm
Spacing of bolt columns (gauge) g = 0 mm
Horizontal Edge distance for plate e2 = 40 mm
Vertical End distance in plate at top e1 = 40 mm
Vertical End distance in plate at bottom e1.1 = 40 mm
Vertical End distance in member at top et = 40 mm
Vertical End distance in member at bottom eb = 40 mm
Horizontal Edge distance for member e3 = 40 mm
Distance between face of supporting member & supported beam (End Projection) t1 = 15 mm
Thickness of fin plate tp' = 8 mm
Thickness of reinforcement plate (doubler plate) twrp = 0 mm
Nr of shear planes Ns = 1
2 2
Sum of square of 'r' for the bolt group r = 20,000 mm

Minimum Shank Tension P0 = N.A. kN


Hole Factor for Standard Size Holes kbs = 1
Slip factor for Class A m = N.A.
Leg length of the fillet weld s = 6 mm
Hole Factor for Standard Size Holes (For Axial force) kbs = 1
Lenght of fin plate, l = 280.0 mm Depth of top notch dct = 0 mm
Width of fin plate, Bf = 95.0 mm Depth of bottom notch dcb = 0 mm
Thickness of fin plate, tp = 8.0 mm Effective Net Area Co-efficient Ke = 1.2 (For Plate)
TOS to first bolt hole = 75.0 mm Ke = 1.2 (For Section)
Fin Plate Type = Extended:Stiffened
Jun 29, 2017
SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN

D-01 00

0.815 Web strengthening stiffener for the supporting member is not required.
Safe. Bearing capacity per bolt Pbs = 73.60 kN > Fs ( 59.96 )
0.815 (Bearing of bolts on the fin plate and beam web)
Safe. Shear Capacity per bolt Ps = 132.32 kN > Fs ( 59.96 )
0.453
Safe. Shear capacity of fin plate Pv.min = 321.55 kN > Fv ( 50.00 )
0.155
Safe. Moment capacity of fin plate Mc = 28.7 kN.m > Fv a ( 6.85 )
0.238 (Shear and bending interaction)
Safe. Lateral Torsional buckling resistance = 28.75 kN.m > Fv a ( 2.75 )
0.096 moment of fin plate Long fin plate, This check is required
Safe. Tension capacity of fin plate = 340 kN >T ( 70.00 )
0.206
Safe. Compression Capacity of fin plate = 381 kN >C ( 70.00 )
0.184
Safe. Shear capacity of the beam at Pv.min = 485.42 kN > Fv ( 50.00 )
0.103 the connection
N.A. Moment capacity of the notched beam = N.A. kN.m > Mnc ( N.A. )
th
(Shear and bending interaction at n col. of bolts) Since the beam is not notched, this check is not required.
Safe. Moment capacity of the beam web = 33.27 kN.m > Fv{ a+(nc-1)*g} ( 6.85 )
0.206 (Shear and bending interaction of the beam web) Long fin plate, This check is required
Safe. Tension capacity of Supported beam = 459 kN >T ( 70.00 )
0.152
N.A. Moment capacity of beam at the notch = N.A. kN.m < McN ( N.A. )
in the presence of shear Since the beam is not notched, this check is not required.
N.A. Local stability of notched beam Since the beam is not notched, this check is not required.
Safe. Weld connecting fin plate to supporting = 0.017 < 1 ( 6.00 mm)
0.017 beam / column (Utilization ratio)
N.A. Local shear capacity of supporting beam = N.A. kN > Fv/2 ( N.A. )
Since the beam Supported by Column Flange, this check is not required.
N.A. Punching shear capacity of supporting beam = N.A. mm > tp ( N.A. )
Since the beam Supported by Column Flange, this check is not required.
N.A. Local shear capacity of supporting beam = N.A. kN > Fv1A/2+Fv2/2 ( N.A. )
web or column web supporting two beams:
Recommended detailing practice is satisfied.
Structural Integrity Checks (For Tying Force)
These checks are only needed if it is necessary to comply with structural integrity requirements.
Safe Weld connecting fin plate to supporting = 0.106 < 1 ( 6.00 mm)
0.106 beam / column (Utilization ratio)
Safe. Tension capacity of fin plate = 481.1 kN > Tie Force ( 75.00 )
0.156
Safe. Bearing capacity of fin plate = 220.8 kN > Tie Force ( 75.00 )
0.340
Safe. Tension capacity of beam web = 481.1 kN > Tie Force ( 75.00 )
0.156
Safe. Bearing capacity of beam web = 298.1 kN > Tie Force ( 75.00 )
0.252
N.A. Tying capacity of web of supporting member = N.A. kN > Tie Force ( 75.00 )
Web strengthening stiffener for the supporting member is not required.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000

SHEAR CONNECTION USING FIN PLATE - BEAM TO COLUMN

Connection identification D-01

Supporting member D1 = 355.0 mm tw1 = 7.4 mm r1 = 10.2 mm


(Beam / Column) B1 = 171.5 mm Tf1 = 11.5 mm D'1 = 311.6 mm
UB 356x171x51 A1 = 64.9 cm2

Supported Beam D2 = 536.7 mm tw2 = 10.8 mm r2 = 12.7 mm


UB 533x210x101 B2 = 210.0 mm Tf2 = 17.4 mm D'2 = 476.5 mm
A2 = 129.0 cm2
Member End Actions
Factored
Compressive force C = 70.0 kN
Tensile force T = 70.0 kN
Vertical Shear force Fv = 50.0 kN
Tying force Tf = 75.0 kN
Web connection
Connection details
Grade of bolt = Gr. 8.8 Bearing Connections
Grade of material Rolled sections = S 275 Plates - S 275
Minimum Tensile Strength Us.b = 410.0 M Pa Us.f = 410.0 M Pa
Minimum Yield Strength = Design strength Supported beam: py.b = 275.0 M Pa Fin Plate: py.f = 275.0 M Pa
Minimum Yield Strength = Design strength Supporting beam: py.b = 265.0 M Pa Reinforcement p py.f = N.A. M Pa
Bearing Strength pbs.b = 460.0 M Pa pbs.f = 460.0 M Pa
Shear Strength of Bolt ps = 375.0 M Pa
Tensile Strength of Bolt pt = 560.0 M Pa
Bearing Strength of bolt pbb = 1000.0 M Pa
Minimum Shank Tension Po = N.A. kN
Design Strength of Weld pw = 250.0 M Pa
Diameter of bolt d = 24.0 mm
Diameter of bolt hole Dh = 26.0 mm
Area of one nominal bolt Ab = 452.4 mm2
Effective area of one bolt At = 352.9 mm2
Nr of bolt column nc = 1
Nr of bolt rows nr = 3
Nr of bolts n = 3
Spacing of bolt rows (pitch) p = 100.0 mm
Spacing of bolt coumns (gauge) g = 0.0 mm
Horizontal Edge distance for member e3 = 40.0 mm
Horizontal Edge distance for plate e2 = 40.0 mm
Vertical End distance in plate at top e1 = 40.0 mm
Vertical End distance in plate at bottom e1.1 = 40.0 mm
Vertical End distance in member at top et = 40.0 mm
Vertical End distance in member at bottom eb = 40.0 mm
Dist. between face of supporting mem. & supported beam t1 = 15.0 mm (End Projection)
Length of fin plate lf = 280.0 mm
Width of fin plate Bf = 95.0 mm
Thickness of fin plate tp = 8.0 mm ( 1 - 8 mm plate )
Thickness of reinforcement twrp = 0.0 mm
Total thickness of web tw = 10.8 mm
Least thickness of connected parts t = 8.0 mm
Nr of shear planes Ns = 1
Sum of square of 'r' for the bolt group r
2
= 20000.0 mm2
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000
Check 1 : Recommended detailing practice
Length of fin plate l = 40 + (2 * 100 )+ 40 < 0.6D2
(To give adequate "nominal torsional restraint" = 280.0 mm ( 213.0 ) Safe.
BS 5950-1 Table 13 and cl.4.2.2)
Spacing of Bolts
Minimum spacing of bolts = 2.5 d > Min.(p,g)
= 60.0 mm ( 100.0 ) Safe.
Maximum spacing of bolts = 14 t > Max.(p,g)
= 112.0 mm ( 100.0 ) Safe.
End & Edge Distances of Bolts
Minimum end and edge distances of bolts = 1.25 Dh <= Min.(e1, e1.1, e2,e3, et, eb)
= 32.5 mm ( 40.0 ) Safe.
Maximum end and edge distances of bolts = 11 t > Max.(e1, e1.1, e2,e3)
= 88.0 mm ( 40.0 ) Safe.
Type of fin plate based on the length, tp / a = 0.145 < 0.15, long fin plate
Recommended detailing practice is satisfied.
Check 2: Supported beam - Bolt Group
Basic Requirement ( Bearing of bolts on fin plate and beam web)
Fs < Pbs
Vertical Reaction Fv = 50.0 kN
Eccentricity of FV about c.g. of bolt group e = 0.5*(B1-tw1)+ t1+e3+0.5
For shear connection
= 137.1 mm
Moment due to eccentricity M = FV*e e = 137.05
= 6.85 kN.m
2 2
Distance of outermost bolt from cg of bolt group r = Sqrt(((nc-1)*g/2) +((nr-1)*p/2) )
= 100.0 mm
Sum of square of 'r' for all bolts r
2
= 20,000.0 mm2
Vertical force on a bolt due Fsv = Fv/n
to direct shear = 16.67 kN
Horizontal force on a bolt due Fah = Max (C , T)/n
to Axial Force = max(70 , 70) /3
= 23.33 kN
2
Maximum shear in bolt due to M Fm = Me*r/Er
= 34.26 kN
Vertical force on the outermost bolt Fsmv = Fm * cosq q = 90
due to moment M, = 0.00 kN
Horizontal force on the outermost bolt Fsmh = Fm * sinq
due to moment M, = 34.26 kN
Total vertical force on a bolt Fvb = Fsv + Fsmv
= 16.67 kN
Total horizontal force on a bolt Fhb = Fah + Fsmh
= 57.60 kN
Resultant force on outermost bolt Fs = Sqrt (Fvb2 + Fhb2)
= 59.96 kN

Bearing Capacity per bolt Pbs = Min. (Pbs.f , Pbs.b ) (Indicative)


Bearing Strength of the plate per bolt Pbs.f = kbs*d*tp*pbs.f < 0.5 * kbs*min.(e1, e1.1,e2)*tp*pbs.f
= 73.60 kN where, kbs = 1.0
for Standard Size Holes
Bearing Strength of the web per bolt Pbs.b = kbs*d*tw*pbs.b < 0.5 * kbs*min.(et, eb,e3)*tw*pbs.b
= 99.36 kN where, kbs = 1.0
for Standard Size Holes
Bearing Capacity per bolt Pbs = 73.60 kN > Fs Safe.
( 60.0 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000
Shear Capacity per bolt Ps = Min. (Ps1 & Ps2 below)
1.0 Shear capacity per bolt with no reductions Ps1 = ps * As * Ns where, As = At
= 132.3 kN
2.0 Shear capacity per bolt with reduction for large grip length
(if total thickness of connected plies, Tg > 5d) Ps = ps * As * Ns * { 8d / (3d+Tg)}
where, Tg = 18.8 mm & 5d = 120.0 mm. = 132.3 * 2.11
Ps2 = N.A. kN ( Tg<5d)
3.0 Shear capacity reduction for Long Joint Ps = ps * As * Ns * { 5500-Lj / 5000}
Lj = 200 mm 132.3 * 1.06 ( Lj<500)
Ps3 N.A. kN
Shear Capacity per bolt Ps = 132.3 kN > Fs Safe.
( 60.0 )
Connection designed to be Non-Slip under factored loads
Slip resistance of one bolt PSL = N.A.
= N.A.
Slip factor m = N.A.
Minimum Shank Tension Po = N.A.
PSL = N.A.
Shear Capacity per bolt Pb = 132.3 kN > Fs Safe.
( 60.0 )

Check 3: Supported beam - Connecting elements


Shear and bending capacity of fin plate connected to supported beam
(i) For Shear:
Basic requirement, Fv < Pv.min
Shear capacity of fin plate Pv.min = Min.{Plain shear capacity (Pv) , Block shear capacity (Pr1)}
Plain shear capacity of fin plate Pv = Min. (0.6pyAv , 0.7pyKe Av.net)
Shear Area Av = 0.9 [e1+e1.1+(nr-1)p] tp
= 2016.00 mm2
Net Shear Area after deducting holes Av.net = Av - nr*Dh*tp
= 1392.00 mm2
Effective net area coefficient Ke = 1.20
Plain shear capacity of fin plate Pv = Min. { 332.64 kN, 321.55 kN }
= 321.55 kN
Block shear capacity of fin plate Pr1 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 240.00 mm
Length of tension face Lt = 40.00 mm
Coefficient k = 0.50
Pr1 = 359.57 kN Pr1
Block shear capacity of fin plate Pr = Pr1 = 359.57 kN
Shear capacity of fin plate Pv.min = 321.55 kN > Fv Safe.
( 50.0 )
(ii) Shear and bending interaction
Basic requirement, Fv a < Mc
For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of fin plate Fv <= 0.75 Pv.min
Mc = py * tp (e1+e1.1+(nr-1)p)2 Low Shear
*
6
= 28.75 kN-m
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of fin plate
Mc = py * tp * (e1+e1.1+(nr-1)p)2 * { 1 - (Fv/Pv.min)^2 }1/2
6
= N.A. kN-m
Moment capacity of fin plate Mc = 28.75 kN-m > Fv a Safe.
( 6.9 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000

(iii) Lateral torsional buckling resistance of long fin plates (Long Fin Plate)

Basic requirement, Fv a < Mb / mLT &


Fv a < py Zx
Lateral torsional buckling moment of resistance of fin plate,
Mb = pb Z x
Elastic modulus of fin plate about major axis Zx = tp * l 2
6
Zx = 104,533.3 mm3
LT = 2.8 * { Lel / 1.5tp2}^1/2 (cl. B.2.7, BS5950-1:2000)
Le = 1 a
Le = 55.00 mm
LT = 35.46
mLT = 0.60 (Table 18 of BS5950-1 2000)
pE * py
Bending strength of fin plate pb = 2
LT + (LT -pEpy )^0.5

E / LT2
2
pE =
= 1608.75 M Pa
LT = [py + ( LT+1) pE] / 2
Robertson constant LT = 7.00 (Cl. B.2.2 of BS5950-1 2000)
Limiting slenderness ratio Lo = 0.4 (2 E / py )^0.5
= 34.31
Perry factor LT = 0.02
LT = 954.87 M Pa
Bending strength of fin plate pb = 269.77 M Pa
Lateral torsional buckling resistance Mb = pb Z x
moment of fin plate = 28.20 kN-m
Mb / mLT = 47.00 kN-m > Fv a Safe.
( 2.8 )
py Zx = 28.75 kN-m > Fv a Safe.

(iv) Tension Capacity


Basic requirement, T < Min ( Ptf, Prf)
Tensile capacity of fin plate Ptf = py*Aeff
Aeff = Ke*An < Ag
An = (l-nr*Dh)*tp
= 1616 mm2
Ke = 1.2
Aeff = 1939.2 mm2
= 533 kN

Block Shear Capacity of Fin plate Prf = Min(Pr1, Pr2)


Pr2 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 80 mm
Length of tension face Lt-kDh = 148 mm
Pr2 = 340 kN Pr1 Pr2

Block Shear Capacity of Fin plate Prf = 340 kN (Indicative)

Tension Capacity of fin plate = 340 kN > T


(Tension Yielding & Block Shear) ( 70.0 ) Safe.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000
(v) Compression Capacity
Basic requirement, C < Pcf
Compression Capacity of fin plate Pc = pc*Ag
Area of fin plate Ag = l *tp
2
= 2240 mm
Unsupported length L = t1+e3+((B1-tw1)/2)
= 137.05 mm
Effective Length Leff = 1.2L
= 164 mm Table 24 for Curve 'b' in BS:5950:1:2000
Radius of gyration rmin = t/sqrt(12) Py = 275
= 2.31 mm
Slenderness ratio = Leff/rmin pc
= 71.2 72.00 236.00
Width of fin plate (Whitmore section of 30 deg) w = 0 71.2 238.36
Compressive stress area = 1600 mm2 74.00 230.00
(Min of Ag & Awhitmore)
Pcf = 381 kN > C
( 70.0 ) Safe.

Check 4: Supported beam - Capacity at the connection


Shear and bending capacity of supported beam
(i) For Shear:
Basic requirement, Fv < Pv.min
Shear capacity of the beam at the connection Pv.min = Min (Pv, Pr1)
Plain shear capacity of beam Pv = Min. (0.6pyAv , 0.7pyKe Av.net)
Shear Area Av = (et+eb+(nr-1)*p)*tw
= 3024.00 mm2
Net Shear Area after deducting holes Av.net = Av - nr*Dh*tw
= 2181.60 mm2
Effective net area coefficient Ke = 1.20
Plain shear capacity of beam Pv = Min. { 498.96 kN, 503.95 kN }
= 498.96 kN
Block shear capacity of beam Pr1 = 0.6 py tw [Lv+Ke(Lt-kDh)]
(Applicable to notched beams only)
Length of shear face Lv = 240.00 mm
Length of tension face Lt = 40.00 mm
Coefficient k = 0.50
Block shear capacity of beam Pr1 = 485.42 kN (Indicative)

Shear capacity of the beam at the connection, Pv.min = 485.42 kN > Fv Safe.
( 50.0 )

(ii) Shear and bending interaction at the nth column line of bolts, if the notch length c > (e3+g)

Basic requirement, Mnc < McC


where Mnc = Fv (t1+e3+(nc-1)*g)
Depth of top notch dct = 0.0 mm
Depth of bottom notch dcb = 0.0 mm
Length of notching c = 0.0 mm No Notching. This check is not required.
Since the beam is not notched, this check is not required.
Design load Fv = 50.0 kN
Eccentricity for Fv (t1+e3+(nc-1)*g) = 0 mm
th
Moment at the n column line of bolts Mnc = 0.0 kN.m.
Depth of beam web at notched section Dc = 501.9 mm
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000
Breadth of flange B2' = 210.0 mm
Area of web at notched section Aw' = tw*Dc
= 5420.5 mm2
Area of flange at notched section Af' = tf2*B2
= 3654.0 mm2
Distance of c.g. from soffit of the beam c1 = D2/2
= 268.35 mm
M.I. of the notched section I' = N.A. cm4
Extreme fibre distance ymax = 268.4 mm
3
Sectional modulus at notched section Z = N.A. cm
For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of the notched beam
at the connection in the presence of shear, McC = py Z
McC = N.A. kN.m.
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of the notched beam
at the connection in the presence of shear, McC = 1.5 * py * Z * { 1 - (Fv/Pv.min)^2 }^0.5
= N.A. kN-m
Moment capacity of the notched beam at the connection in the presence of shear,
McC = N.A. kN-m > Mnc N.A.
( N.A. )

(iii) Shear and bending interaction of the beam web section - Long fin plates only (Long Fin Plate)

Basic requirement, Fv { a+ (nc-1)*g} < McBC + PVAB (nr-1)p

For Low Shear (i.e. Fv <= 0.75 Pv.min), moment capacity of the beam web BC
2
Mc BC = py tw [(nr-1)p]
6
= 19.80 kN-m
Shear capacity of the beam web AB Pv AB = Min {( 0.6 py (e3+(nc-1)g)tw),
(0.7pyKe(e3+(nc-1)g+0.5Dh-ncDh)tw)}
= Min. { 71 kN , 67.36 kN }
Pv AB = 67.36 kN
Shear capacity of the beam web BC Pv BC = Min {( 0.6 py (nr-1)p)tw),
(0.7pyKe((nr-1)p+Dh-nrDh)tw)}
= Min. { 356.40 kN , 369.23 kN }
Pv BC = 356.40 kN
Shear force on the beam web BC Fv BC = Fv - (Pv - PVBC ) but > 0
= 0.00 kN
For High Shear (i.e. Fv > 0.75 Pv.min), moment capacity of the beam web BC
py tw [(nr-1)p]2
Mc BC = * {1-(FvBC/PvBC)2}^0.5
4
= N.A. kN-m
Moment capacity of the beam web BC Mc BC = 19.80 kN-m
McBC + PVAB (nr-1)p = 33.27 kN-m > Fv { a+ (nc-1)*g}
( 6.85 ) Safe.
(iv) Tension Capacity
Basic requirement, T < Ptb
Net Tension Capacity of supported beam = Le * tw * pbs
Le = 2ee + (n-1)pe - nDh
ee = Min(e3, et)
= 40.0 mm
pe = Min(p, 2e3)
= 80.00 mm
Le = 162.0 mm
Net Tension Capacity of beam web = 481.1 kN
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000

Block Shear Capacity of Supported beam Prb = Min(Pr1, Pr2)


Pr2 = 0.6 py tp [Lv+Ke(Lt-kDh)]
Length of shear face Lv = 80 mm
Length of tension face Lt-kDh = 148 mm
Pr2 = 459 kN Pr1 Pr2
Block Shear Capacity of Fin plate Prf = 459 kN (Indicative)

Tension Capacity of supported beam = 459 kN > T


(Tension Yielding & Block Shear) ( 70.0 ) Safe.

Check 5: Supported beam - Capacity at notch


Shear and bending interaction at the notch:
Basic requirement, Mnc < McN
where Mnc = Fv (t1+c)
Depth of top notch dct = 0.0 mm
Depth of bottom notch dcb = 0.0 mm
Length of notching c = 0.0 mm
Since the beam is not notched, this check is not required.

Design load Fv = 50.0 kN


Eccentricity for Fv (t1+c) = 0 mm
Moment at the notch location Mnc = 0.0 kN.m. (Indicative)
Depth of beam web at notched section Dc = 501.9 mm
Breadth of flange B2' = 210.0 mm
Area of web at notched section Aw' = tw*Dc xN = |{c - [e3+(nc-1)*g]}|
2
= 5420.5 mm
Area of flange at notched section Af' = tf2*B2 xN = 40 mm
= 3654.0 mm2
Distance of c.g. from soffit of the beam c1 = D2/2
= 268.35 mm
M.I. of the notched section I' = N.A. cm4
Extreme fibre distance ymax = 268.4 mm
Sectional modulus at notched section ZN = N.A. cm3
Shear capacity at the notch PvN = 0.6pyAvN
= 498.96 kN
Shear at notch AvN = [et+eb+(nr-1)p] tw
= 3024.00 mm2

For Low Shear (i.e. Fv <= 0.75 PvN), moment capacity of beam at the notch
in the presence of shear, McN = py Zn (Indicative)
McN = N.A. kN.m.
For High Shear (i.e. Fv > 0.75 PvN), moment capacity of beam at the notch
in the presence of shear, McN = 1.5 * py * Z * { 1 - (Fv/PvN)^2 }^0.5
= N.A. kN-m
Moment capacity of beam at the notch, in the presence of shear,
a) for single bolt line or for double bolt lines, if xN > 2d
McN = N.A. kN-m
Mnc = Fv * (t1 + c) = N.A. kN-m N.A.

b) for double bolt lines, if xN < 2d McN = N.A. kN-m


Mnc = Max [Fv * (t1 + c), Fv(t1+e3+(n-1)*g)] = N.A. kN-m N.A.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000
Check 6: Supported beam - Local stability of notched beam
For one flange notched
Basic requirement, dct < D/2 N.A.
D/tw = 49.7 c < D for D/tw < 54.3 N.A.

c < 54.3 *D for D/tw > 54.3 N.A.


3
(D/tw)
For both flanges notched
Basic requirement, Max (dct , dct ) < D/5 N.A.
D/tw = 49.7 c < D for D/tw < 54.3 N.A.

c < *D
54.3 for D/tw > 54.3 N.A.
(D/tw)3
Since the beam is not notched, this check is not required.

Check 7: Weld between fin plate and web of supporting member


Transverse Shear in weld FT = 70.0 kN Angle between FT & throat of weld,
Longitudinal Shear in weld FL = 50.0 kN q = 45 deg
Strength of weld pw = 250 M Pa
Size of weld provided s = 6 mm
Length of weld lw = (l - 2s)*2
= 536 mm
Longitudinal shear capacity, PL = pw * a* lw
= 568.4 kN
2
Transverse shear capacity, PT = K * PL where, K = 1.25*sqrt(1.5/(1+cos q))
K = 1.25
= 710.5 kN
Interaction (FL/PL)^2 + (FT / PT)^2 = 0.017 < 1 < 1 Safe.

Check 8: Supporting beam / column - Local capacity


(i) Local shear capacity of supporting member:
Basic requirement, Fv / 2 < Pv
Local shear capacity of Supporting Column web
Pv = 0.6 py Av
Av = 0.9 l tw
2
= 1864.8 mm
Pv = N.A. kN > Fv / 2 ( N.A. ) N.A.
Since the beam Supported by Column Flange, this check is not required.
(ii) Punching shear capacity of supporting member:
Yielding of the fin plate occurs before punching shear failure of the supporting member.
Basic requirement, tp < tw (Usc / fb)
Maximum bending stress in the fin plate fb = Fv a / Zgross & fb py.f
Zgross = tp l 2 / 6
= 104533.3 mm3
fb = 26.3 M Pa
tw (Usc / fb) = N.A. mm > tp ( N.A. ) N.A.
Since the beam Supported by Column Flange, this check is not required.
(iii) Local shear capacity of Supporting Column web, if supporting two beams:
Basic requirement, Fv1A / 2 + Fv2 / 2 < Pv
Local shear capacity of supporting beam Pv = 0.6 py Av
web or column web Av = 0.9 l2 tw Fv1A = Fv1 l2/l1 l2 = 0
= 1864.8 mm2 Fv2 = 0 KN
Pv = N.A. kN > Fv1A / 2 + Fv2 / 2
( N.A. ) N.A.
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000
Check 9: Structural integrity - Connecting elements
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - tension and bearing capacity of fin plate
(i) For tension
Basic requirement, Tie force < Tension capacity of fin plate
Tension capacity of fin plate = min (py A , Ke py Anet )
A = l f * tp
= 2240.00 mm2
Anet = A - nr*Dh*tp
= 1616.00 mm2
Effective net area coefficient Ke = 1.20
Tension capacity of fin plate = Min. { 616.00 kN, 533.28 kN }
= 533.28 kN > Tie force Safe.
(ii) For bearing ( 75.0 )
Basic requirement, Tie force < Bearing capacity of fin plate
Bearing capacity of fin plate = Min(1.5*nr*d*tf*pbs, 0.5*nr*e2*tf*pbs)
( for nth column of bolts) nc = 1 = 220.8 KN > Tie force Safe.
( 75.0 )
Check 10: Structural integrity - Supported member
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - tension and bearing capacity of supported member web
(i) For tension
Basic requirement, Tie force < Net Tension Capacity of beam web
Net Tension Capacity of beam web = Le * tw * pbs
Le = 2ee + (n-1)pe - nDh
nc = 1 ee = Min(e3, et)
= 40.0 mm
pe = Min(p, 2e3)
= 80.00 mm
Le = 162.0 mm
Net Tension Capacity of beam web = 481.1 kN > Tie force Safe.
( 75.0 )
(ii) For bearing
Basic requirement, Tie force < Bearing capacity of beam web
Bearing capacity of beam web = Min(1.5nr*d*tw*pbs, 0.5nr*e3*tw*pbs)
th
( for n column of bolts) = 298.1 kN > Tie force Safe.
( 75.0 )
Check 11: Structural integrity - Supporting member web
This check is only needed if it is necessary to comply with structural integrity requirements
Structural integrity - Tying capacity of supporting member web, in the presence of axial compression in the column
Basic requirement,
Tie force < Tying capacity of supporting member (Column) web
Tying capacity of supporting Column web = 8 Mu 0.5 Where, 1.5 in eqaution
{ 1 + 1.5(1-1) }
1 - 1 includes an allowance
Moment capacity of supporting Column web Mu = pu tw2 / 4 for the axial compression
per unit length in the column
Design Tensile Strength of supporting Column web pu = Us / 1.25 Supporting Member
(Floor beam)

( Design tensile strength, pu = 328 MPa 328.00 MPa tp 'tp' THK PLATE

BS EN 10025: 1993) Mu = 4490.32 N.mm/mm


dc
lp

lp

(Tie force)

= (l-2*s) / dc
= 0.86 Supporting Member

= (tp + 2s) / dc
(Floor beam)

FIN PLATE CONNECTING TO BEAM WEB

= 0.06
Tying capacity of supporting Column web = N.A. kN > Tie force N.A.
Web strengthening stiffener for the supporting member is not required. ( 75.0 )
Sheet
of
PROJECT Designed by
CANOPY FRAMING SAB
Date Checked by
SUBJECT Jun 29, 2017 ASV
Doc. Reference
DESIGN OF STEEL WORK CONNECTIONS D-01 BS 5950-1 :2000
Check 12: Supporting beam / column - Welds (Tying Force)
Weld between fin plate and beam web
Transverse Shear in weld FT = 75.0 kN Angle between FT & throat of weld
Longitudinal Shear in weld FL = 0.0 kN q = 45 deg
Strength of weld pw = 250 M Pa
Size of weld provided s = 6 mm
Length of weld lw = (l - 2s)*2
= 536.0 mm
Longitudinal shear capacity, PL = pw * a* lw
= 568.4 kN
Transverse shear capacity, PT = K * PL
where, K = 1.25*sqrt(1.5/(1+cos2q))
K = 1.25 = 710.5 kN
Interaction (FL/PL)^2 + (FT / PT)^2 = 0.1056 < 1 Safe

Check 13: Block Shear Capacity at the connection for Tie force

(i) For Fin Plate:


Basic requirement Tie force < Block shear capacity of fin plate
Block shear capacity of fin plate Prf = 0.6 py tp [Lt+Ke(Lv-kDh)]
Length of shear face Lv = 40 mm
Length of tension face Lt = 240 mm
Coefficient k = 0.50
Prf = 359.57 kN
Block shear capacity of fin plate Prf = 359.57 kN > Tie force Safe.
( 75.0 )
(ii) For Supported beam web:
Basic requirement Tie force < Block shear capacity of supported beam web
Block shear capacity of fin plate Prb = 0.6 py tw [Lt+Ke(Lv-kDh)]
Length of shear face Lv = 40 mm
Length of tension face Lt = 240 mm
Coefficient k = 0.50
Prb = 485.42 kN
Block shear capacity of fin plate Prb = 485.42 kN > Tie force Safe.
( 75.0 )
Check 14: Check for Supporting member web due to axial force

Tying capacity of supporting member web for axial force

Tying capacity of supporting Column web = 8 Mu 0.5 Where, 1.5 in eqaution


{ 1 + 1.5(1-1) }
1 - 1 includes an allowance
Moment capacity of supporting Column web Mu = pu tw2 / 4 for the axial compression
per unit length in the column
Design Tensile Strength of supporting Column web pu = Us / 1.25 Supporting Member

( Design tensile strength, pu = 328 MPa 328.00 MPa


(Floor beam)

tp 'tp' THK PLATE

BS EN 10025: 1993) Mu = 4490.32 N.mm/mm


dc
lp

lp

(Tie force)

= (l-2*s) / dc
= 0.90 Supporting Member
(Floor beam)

= (tp + 2s) / dc FIN PLATE CONNECTING TO BEAM WEB

= 0.06
Tying capacity of supporting Column web = N.A. kN > Axial force N.A.
Web strengthening stiffener for the supporting member is not required. ( 70.0 )


Beam End Force Summary
The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 122 91 210:DL+1.4WL 58.456 55.175 -0.126 -0.008 0.127 138.836
Min Fx 124 93 218:1.2DL+1.2L -63.462 52.360 13.988 0.007 -10.129 92.654
Max Fy 118 90 202:1.4DD+1.4 -0.401 184.793 1.088 -0.320 -1.706 560.563
Min Fy 118 90 209:DL+1.4WL 0.195 -269.061 -0.622 0.272 0.970 -655.404
Max Fz 124 93 218:1.2DL+1.2L -63.462 52.360 13.988 0.007 -10.129 92.654
Min Fz 124 93 10:TEMP +VE 46.536 14.485 -8.519 0.015 5.801 36.651
Max Mx 118 90 209:DL+1.4WL 0.195 -269.061 -0.622 0.272 0.970 -655.404
Min Mx 118 90 202:1.4DD+1.4 -0.401 184.793 1.088 -0.320 -1.706 560.563
Max My 349 312 218:1.2DL+1.2L -34.837 -55.757 -4.645 0.129 12.056 -1.363
Min My 349 312 217:1.2DL+1.2L -7.788 -65.857 4.332 0.051 -11.260 12.444
Max Mz 118 90 202:1.4DD+1.4 -0.401 184.793 1.088 -0.320 -1.706 560.563
Min Mz 118 90 209:DL+1.4WL 0.195 -269.061 -0.622 0.272 0.970 -655.404

Y
X
Z Load 1

Whole Structure
Autodesk Robot Structural Analysis Professional 2017
Author: File:
Address: Project: Structure

STRESS ANALYSIS IN THE BAR

CROSS SECTION
UB533 TO CHS COLUMN WELD AS FPBW ALLAROUND < 239N/MM2 SAFE

Stress analysis type (hypothesis) : von Mises

Internal forces taken into account : Fx Fy Fz Mx My Mz

RESULTS IN THE SECTION

Forces applied to the section


Fx = 1.00 kN Mx = 1.00 kN*m
Fy = 1.00 kN My = 656.00 kN*m
Fz = 270.00 kN Mz = 1.00 kN*m

Extreme stresses in the section


sX max sX min tXYmax tXZmax
Stresses 238.06 MPa -237.93 MPa 13.54 MPa 49.67 MPa
Y local -105.95 mm 105.95 mm 0.94 mm 4.69 mm
Z local 272.25 mm -272.25 mm -272.25 mm -2.41 mm

tmax si max
Stresses 49.67 MPa 238.29 MPa
Y local 4.69 mm -94.70 mm
Z local -2.41 mm 272.25 mm

Date : 29/06/17 Page : 1


Sheet of
Designed by SAB
Job no 22004 Checked by ASV
PROJECT CANOPY FRAMING
Date 17.11.12 Aprroved by ASV
SUBJECT DESIGN OF STRUCTURAL STEEL WORK CONNECTIONS Reference BS-5950 & ENV 1993-1-1-Annex K

LOCAL CHECKS FOR CHS CHORDS & I-SECTION BRACING


T & Y-JOINT

Member profiles Result summary


Supporting Chord Joint capacity of chord Utility
CHS355X12.5 12THK PLT SHOULD BE REINFORCED INTO CHS Axial capacity 0.00
d0 = 355.0 mm t0 = 24.5 mm A0 = 254.38 cm2 Inplane Moment 0.94
Out of Plane moment 0.01
Axial & Moment interaction 0.89
Shear capacity 0.07
Brace/Beam Member UB533X210X122
2 3
h1 = 544.50 mm t1 = 21.30 mm A1 = 155.00 cm Zx1 = 2793.00 cm
3
b1 = 154.4 mm tw = 12.70 mm d' = 476.5 mm Zy1 = 320.00 cm
r = 12.70 mm
Design Input
Grade of material = S 275
Nominal yield strength of chord fy0 = 275.00 N/mm2
Nominal yield strength of bracing fyi = 275.00 N/mm2
Angle between bracing member and the chord 1 = 90 deg
Multi planar joint coefficient = 1

Member Forces (Ultimate Loads)


Brace/Beam Member UB533X210X122
Compressive Force C1 = 1.00 kN
Tensile Force T1 = 1.00 kN
Vertical Shear Force Fz1 = 270.00 kN
Horizontal Shear Force Fy1 = 1.00 kN
Torsion Mx1 = 1.00 kNm
Minor axis moment Mz1 = 1.00 kNm
Major axis moment My1 = 656.00 kNm

Force resolution
Axial force in the member Fxc = max(C1,T1)
= 1.00 kN
Out of plane moment Mz1 = 1.00 kNm
(Minor Axis Moment for Brace/Beam)
In plane moment My1 = 656.00 kNm
(Major Axis Moment for Brace/Beam)
CHS chord parameter limits (Ref: 5.1.1)
T-joint
Limit 1: d0/t0 50
d0/t0 = 14.49 < 50.00 Hence OK

Limit 2: bi/d0 0.4


bi/d0 = 0.43 >= 0.4 Hence OK

Limit 3: hi/d0 4.00


hi/d0 = 1.53 < 4 Hence OK

0
Limit 5: 300 90
Inclination angle = 1 = 90.00 deg Hence OK

CHS chord joint functions (Ref: 5.1.2)

Chord end load function (Assumed) f(np) = 1.00

CHS chord and I-bracing with Axial load: (Ref: 5.1.7)

Chord face deformation for axial force Ni = (fyo*t02*(4+20*2)*(1+0.25h1/d0)*f(np)* = bracing to chord width ratio
= 1777.42 kN = b1/d0 = 0.43
Sheet of
Designed by SAB
Job no 22004 Checked by ASV
PROJECT CANOPY FRAMING
Date 17.11.12 Aprroved by ASV
SUBJECT DESIGN OF STRUCTURAL STEEL WORK CONNECTIONS Reference BS-5950 & ENV 1993-1-1-Annex K

Applied axial force Ni.app = Fxc * Sin + Fz1*Cos


= 1.00 kN < 1777.42 kN Hence Safe
Ratio = 0.00

Chord face deformation check for moments (Ref: 5.1.7)

Chord face deformation for in plane moment Mip,i = (h1*N1)*/(1+0.25h1/d0)


= 699.56 kNm
Applied in plane moment Mip,i,app = My1
= 656.00 kNm < 699.56 kNm Hence Safe
Ratio = 0.94

Chord face deformation for out of plane moment Mop,i = 0.5*(b1*N1)*


= 137.22 kNm
Applied out of plane moment Mop,i,app = Mz1
= 1.00 kNm < 137.22 kNm Hence Safe
Ratio = 0.01

Chord punching shear for axial load & Moments


Ni.app Mip,i,app Mop,i,app =
+ + *t1 5.07 kN/mm
A1 Wel,1 Wel,1

2*fyo*t0/3 = 7.78 kN/mm > 5.07 kN/mm Hence Safe


Ratio = 0.65
Check for Axial load & moment interaction (Ref: 2.4)

For CHS chord, the interaction formula is:

]
2
Ni,app +
Ni
[ Mip,i,App
Mip,i
+ Mop,i,App
Mop,i
= 0.89 < 1 Hence Safe

Local Shear Capacity


Shear capacity of chord for Vertical shear
Total Vertical shear Vtot = Fz1*sin + Fxc *cos
= 270.00 kN

Shear capacity of chord Pv = 0.6*fyo*d'*t0*2


= 3852.50 kN > 270.00 kN Hence Safe
Ratio = 0.07

Shear capacity of chord for Horizontal shear


Horizontal shear due to torsion H1 = [ Mx1/(h1-t1)]
= 1.91 kN

Total Horizontal shear Htot = (Fy1/2) +H1


= 2.41 kN
B' = b1+(b1-tw-2r)
= 270.70 mm
Shear capacity of chord Pv = 0.6*fyo*B'*t0
= 1094.30 kN > 2.41 kN Hence Safe
Ratio = 0.00
Beam End Force Summary
The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 403 318 217:1.2DL+1.2L 471.980 7.337 -1.076 -0.000 0.000 0.000
Min Fx 403 318 218:1.2DL+1.2L -471.841 7.337 1.561 -0.000 0.000 0.000
Max Fy 452 331 202:1.4DD+1.4 -2.239 13.648 0.257 0.001 0.000 0.000
Min Fy 534 313 202:1.4DD+1.4 -0.290 -16.098 0.032 0.032 -0.000 -0.000
Max Fz 405 323 218:1.2DL+1.2L 94.551 1.200 51.702 -0.011 -36.976 -0.028
Min Fz 405 323 217:1.2DL+1.2L -93.685 1.194 -52.245 -0.015 37.483 -0.013
Max Mx 513 344 211:1.2DL+1.2L -1.315 0.197 -0.000 0.055 0.000 0.000
Min Mx 350 312 209:DL+1.4WL 0.087 1.591 0.050 -0.044 0.000 0.000
Max My 405 323 217:1.2DL+1.2L -93.685 1.194 -52.245 -0.015 37.483 -0.013
Min My 405 323 218:1.2DL+1.2L 94.551 1.200 51.702 -0.011 -36.976 -0.028
Max Mz 524 342 202:1.4DD+1.4 1.506 -12.501 0.018 -0.008 0.001 5.552
Min Mz 488 179 202:1.4DD+1.4 -1.541 -0.050 -0.072 -0.007 -0.013 -28.296

R2
R2 R2R2
R2R2 R2
R2 R2
R2R2 R2 R2
R2
R2 R2 R2 R2 R2
R2 R2
R2 R2R2
R2 R2 R2
R2 R2 R2
R2R2 R2R2
R2R2 R2R2
R2 R2
R2 R2
R2 R2 R2
R2
R2 R2
R2 R2 R2
R2R2 R2
R2R2 R2
R2 R2
R2 R2R2
R2 R2 R2R2
R2 R2 R2
R2
R2 R2 R2
R2R2 R2
R2 R2R2 R2
R2 R2 R2
R2 R2
R2R2R2 R2R2
R2
R2 R2R2
R2
R2 R2
R2
R2 R2
R2
R2 R2
R2
R2 R2R2
R2 R2 R2R2
R2
R2
R2R2 R2 R2
R2
R2R2

Y
X
Z Load 1

Whole Structure
REJANI Page 1 of 4
Job: Unnamed -- Connection: UB356X171X51MC 06/29/2017
11:15:51 PM

CONNECTION: UB356X171X51MC - Bolted Moment End Plate


End plate: 200x20x382 Gr.S275
Flange weld: FPBW/440 - Web weld: 6 FW/440
Bolts: 8 x M20 8.8/N in 2 cols. at 120 gauge

50

80 178

Gr.S275
UB356X171X51 UB356X171X51
95
C1 B1

80

6
Plates: 12.0 kg
Bolts: 3.6 kg
Welds: 0.3 kg

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


REJANI Page 2 of 4
Job: Unnamed -- Connection: UB356X171X51MC 06/29/2017
11:15:51 PM

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


REJANI Page 3 of 4
Job: Unnamed -- Connection: UB356X171X51MC 06/29/2017
11:15:51 PM

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


REJANI Page 4 of 4
Job: Unnamed -- Connection: UB356X171X51MC 06/29/2017
11:15:51 PM

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


Beam End Force Summary
The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 135 106 217:1.2DL+1.2L 161.081 5.569 2.742 -0.001 -4.683 -22.645
Min Fx 135 106 218:1.2DL+1.2L -162.922 4.267 -4.341 -0.000 7.114 -24.744
Max Fy 124 93 202:1.4DD+1.4 -13.325 121.704 5.861 0.045 -4.929 234.727
Min Fy 125 92 209:DL+1.4WL -0.283 -165.824 -0.758 -0.007 0.833 -287.082
Max Fz 128 104 217:1.2DL+1.2L -9.359 -52.371 35.074 0.051 -32.304 -19.388
Min Fz 128 104 218:1.2DL+1.2L -32.733 -42.272 -32.687 0.129 31.668 -27.138
Max Mx 128 104 202:1.4DD+1.4 -36.247 -80.570 1.859 0.153 -0.491 -38.922
Min Mx 140 104 209:DL+1.4WL 0.969 -43.436 0.020 -0.148 -0.028 -140.718
Max My 128 104 218:1.2DL+1.2L -32.733 -42.272 -32.687 0.129 31.668 -27.138
Min My 128 104 217:1.2DL+1.2L -9.359 -52.371 35.074 0.051 -32.304 -19.388
Max Mz 141 94 202:1.4DD+1.4 -1.630 74.408 0.217 -0.089 -0.297 295.286
Min Mz 125 92 209:DL+1.4WL -0.283 -165.824 -0.758 -0.007 0.833 -287.082

R2
R2 R2R2
R2R2 R2
R2 R2
R2R2 R2 R2
R2
R2 R2 R2 R2 R2
R2 R2
R2 R2R2
R2 R2 R2
R2 R2 R2
R2R2 R2R2
R2R2 R2R2
R2 R2
R2 R2
R2 R2 R2
R2
R2 R2
R2 R2 R2
R2R2 R2
R2R2 R2
R2 R2
R2 R2R2
R2 R2 R2R2
R2 R2 R2
R2
R2 R2 R2
R2R2 R2
R2 R2R2 R2
R2 R2 R2
R2 R2
R2R2R2 R2R2
R2
R2 R2R2
R2
R2 R2
R2
R2 R2
R2
R2 R2
R2
R2 R2R2
R2 R2 R2R2
R2
R2
R2R2 R2 R2
R2
R2R2

Y
X
Z Load 1

Whole Structure
REJANI Page 1 of 3
Job: Unnamed -- Connection: UB533X210X101MC 06/29/2017
11:26:17 PM

CONNECTION: UB533X210X101MC - Bolted Splice


Gap between ends 10
Flange plates: 200x16x460 Gr.S275
Bolts: 12 x M24 8.8/N in 2 lines at 120 gauge
70 70 4545 70 70

93
70
70 Gr.S275
UB533X210X101
70
B1
70
70

90
Plates: 37.5 kg
Web plates: 2 x 170x12x450 Gr.S275 Bolts: 24.7 kg
Bolts: 12 x M20 8.8/N Welds: 0.0 kg

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


REJANI Page 2 of 3
Job: Unnamed -- Connection: UB533X210X101MC 06/29/2017
11:26:17 PM

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


REJANI Page 3 of 3
Job: Unnamed -- Connection: UB533X210X101MC 06/29/2017
11:26:17 PM

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


Beam End Force Summary
The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 349 312 209:DL+1.4WL 54.532 87.071 0.138 -0.066 -0.342 -48.550
Min Fx 349 312 202:1.4DD+1.4 -36.670 -104.909 -0.247 0.153 0.625 10.102
Max Fy 118 90 202:1.4DD+1.4 -0.401 184.793 1.088 -0.320 -1.706 560.563
Min Fy 118 90 209:DL+1.4WL 0.195 -269.061 -0.622 0.272 0.970 -655.404
Max Fz 349 312 217:1.2DL+1.2L -7.788 -65.857 4.332 0.051 -11.260 12.444
Min Fz 349 312 218:1.2DL+1.2L -34.837 -55.757 -4.645 0.129 12.056 -1.363
Max Mx 118 90 209:DL+1.4WL 0.195 -269.061 -0.622 0.272 0.970 -655.404
Min Mx 118 90 202:1.4DD+1.4 -0.401 184.793 1.088 -0.320 -1.706 560.563
Max My 349 312 218:1.2DL+1.2L -34.837 -55.757 -4.645 0.129 12.056 -1.363
Min My 349 312 217:1.2DL+1.2L -7.788 -65.857 4.332 0.051 -11.260 12.444
Max Mz 118 90 202:1.4DD+1.4 -0.401 184.793 1.088 -0.320 -1.706 560.563
Min Mz 118 90 209:DL+1.4WL 0.195 -269.061 -0.622 0.272 0.970 -655.404

R4

R4

Y
X
Z Load 1

Whole Structure
REJANI Page 1 of 3
Job: Unnamed -- Connection: UB533X210X122MC 06/30/2017
12:12:16 AM

CONNECTION: UB533X210X101MC_2 - Bolted Splice


Gap between ends 10
Flange plates: 200x28x800 Gr.S275
Bolts: 20 x M24 8.8/N in 2 lines at 120 gauge
80 80 80 80 4545 80 80 80 80

97
70
70 Gr.S275
UB533X210X122
70
B1
70
70

60 90 60
Plates: 95.8 kg
Web plates: 2 x 300x12x450 Gr.S275 Bolts: 45.1 kg
Bolts: 24 x M20 8.8/N Welds: 0.0 kg

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


REJANI Page 2 of 3
Job: Unnamed -- Connection: UB533X210X122MC 06/30/2017
12:12:16 AM

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


REJANI Page 3 of 3
Job: Unnamed -- Connection: UB533X210X122MC 06/30/2017
12:12:16 AM

LIMCON V3.63.1.11 C:\Users\REJANI\Desktop\CANOPY-02 CONNECTION\Unnamed.lmc


STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

7.0 ENGINEERING DRAWINGS


CONTRACTOR HAS TO PREPARE
THE DRAWINGS

145 of 341
STAAD INPUT
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Materials
Mat Name E Density
(kN/mm2) (kg/m3) (1/K)
1 STEEL 205.000 0.300 7.83E+3 12E -6
2 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
3 ALUMINUM 68.948 0.330 2.71E+3 23E -6
4 CONCRETE 21.718 0.170 2.4E+3 10E -6

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
2 UB254X102X22 28.000 119.000 2.84E+3 4.145 STEEL
3 PIP35512.5 135.000 19.8E+3 19.8E+3 39.7E+3 STEEL
5 UB533X210X101 129.000 2.69E+3 61.5E+3 100.953 STEEL
6 UB356X171X51 64.900 968.000 14.1E+3 23.811 STEEL
7 UB533X210X122 155.000 3.39E+3 76E+3 178.377 STEEL
8 UB356X127X39 49.800 358.000 10.2E+3 15.097 STEEL

Basic Load Cases


Number Name

1 EQ +X
2 EQ +Z
3 DEAD LOAD
4 SDL
5 LIVE LOAD
6 WL +X PRESSURE
7 WL -X SUCTION
8 WL +Z PRESSURE
9 WL -Z SUCTION
10 TEMP +VE
11 TEMP -VE

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 56
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

101 DD+LL 3 DEAD LOAD 1.00


5 LIVE LOAD 1.00
102 DD+SL+LL 3 DEAD LOAD 1.00
4 SDL 1.00
5 LIVE LOAD 1.00
103 DL+WL 3 DEAD LOAD 1.00
6 WL +X PRESSURE 1.00
104 DL+WL 3 DEAD LOAD 1.00
7 WL -X SUCTION 1.00
105 DL+WL 3 DEAD LOAD 1.00
8 WL +Z PRESSURE 1.00
106 DL+WL 3 DEAD LOAD 1.00
9 WL -Z SUCTION 1.00
107 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
6 WL +X PRESSURE 0.80
108 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
7 WL -X SUCTION 0.80
109 DL+0.8LL+0.8WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
8 WL +Z PRESSURE 0.80
110 DL+0.8LL+0.WL 3 DEAD LOAD 1.00
5 LIVE LOAD 0.80
9 WL -Z SUCTION 0.80
111 0.9DL+1.0EQ 3 DEAD LOAD 0.90
1 EQ +X 1.00
112 0.9DL+1.0EQ 3 DEAD LOAD 0.90
2 EQ +Z 1.00
113 DL+LL+TL 3 DEAD LOAD 1.00
5 LIVE LOAD 1.00
10 TEMP +VE 1.00
114 DL+LL+TL 3 DEAD LOAD 1.00
5 LIVE LOAD 1.00
11 TEMP -VE 1.00
201 1.4DL+1.6LL 3 DEAD LOAD 1.40
5 LIVE LOAD 1.60
202 1.4DD+1.4SL+1.6LL 3 DEAD LOAD 1.40
4 SDL 1.40
5 LIVE LOAD 1.60
203 1.4DL+1.4WL 3 DEAD LOAD 1.40
6 WL +X PRESSURE 1.40
204 1.4DL+1.4WL 3 DEAD LOAD 1.40
7 WL -X SUCTION 1.40
205 1.4DL+1.4WL 3 DEAD LOAD 1.40

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 2 of 56
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Combination Load Cases Cont...


Comb. Combination L/C Name Primary Primary L/C Name Factor

8 WL +Z PRESSURE 1.40
206 1.4DL+1.4WL 3 DEAD LOAD 1.40
9 WL -Z SUCTION 1.40
207 DL+1.4WL 3 DEAD LOAD 1.00
6 WL +X PRESSURE 1.40
208 DL+1.4WL 3 DEAD LOAD 1.00
7 WL -X SUCTION 1.40
209 DL+1.4WL 3 DEAD LOAD 1.00
8 WL +Z PRESSURE 1.40
210 DL+1.4WL 3 DEAD LOAD 1.00
9 WL -Z SUCTION 1.40
211 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
6 WL +X PRESSURE 1.20
212 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
7 WL -X SUCTION 1.20
213 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
8 WL +Z PRESSURE 1.20
214 1.2DL+1.2LL+1.2WL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
9 WL -Z SUCTION 1.20
215 1.2DL+0.5LL+1.0EQ 3 DEAD LOAD 1.20
5 LIVE LOAD 0.50
1 EQ +X 1.00
216 1.2DL+0.5LL+1.0EQ 3 DEAD LOAD 1.20
5 LIVE LOAD 0.50
2 EQ +Z 1.00
217 1.2DL+1.2LL+1.2TL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
10 TEMP +VE 1.20
218 1.2DL+1.2LL+1.2TL 3 DEAD LOAD 1.20
5 LIVE LOAD 1.20
11 TEMP -VE 1.20

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 3 of 56
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams
Beam Node A Node B Length Property
(m) (degrees)
114 78 90 5.200 3 0
115 79 91 5.200 3 0
116 80 92 5.200 3 0
117 82 93 5.200 3 0
118 90 314 2.548 7 0
119 91 319 2.548 5 0
120 93 335 2.432 5 0
121 97 317 0.150 5 0
122 91 316 3.750 5 0
123 92 325 3.750 5 0
124 93 326 1.450 5 0
125 92 334 1.809 5 0
126 93 311 0.835 5 0
128 104 312 0.600 5 0
129 104 219 1.013 5 0
130 106 318 0.600 5 0
131 107 322 0.600 5 0
132 108 323 0.600 5 0
134 107 226 1.012 5 0
135 106 233 1.012 5 0
136 94 320 0.600 5 0
137 95 321 0.600 5 0
138 101 331 0.600 5 0
139 96 332 0.600 5 0
140 104 207 0.862 5 0
141 94 195 0.862 5 0
142 94 123 1.013 5 0
145 95 144 1.017 5 0
146 101 165 1.034 5 0
147 96 186 0.872 5 0
148 108 282 0.835 5 0
151 114 313 0.600 5 0
153 102 339 1.432 5 0
154 102 330 1.450 5 0
157 123 124 1.013 5 0
158 124 125 1.012 5 0
159 125 126 1.013 5 0
160 126 127 1.012 5 0
161 127 128 1.012 5 0
162 128 129 1.013 5 0
163 129 95 1.013 5 0
164 123 130 0.600 2 0
165 131 123 0.600 2 0
166 124 132 0.600 2 0
167 133 124 0.600 2 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 4 of 56
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
168 125 134 0.600 2 0
169 135 125 0.600 2 0
170 126 136 0.600 2 0
171 137 126 0.600 2 0
172 127 138 0.600 2 0
173 139 127 0.600 2 0
174 128 140 0.600 2 0
175 141 128 0.600 2 0
176 129 142 0.600 2 0
177 143 129 0.600 2 0
178 144 145 1.017 5 0
179 145 146 1.017 5 0
180 146 147 1.017 5 0
181 147 148 1.017 5 0
182 148 149 1.017 5 0
183 149 150 1.017 5 0
184 150 101 1.017 5 0
185 144 151 0.600 2 0
186 152 144 0.600 2 0
187 145 153 0.600 2 0
188 154 145 0.600 2 0
189 146 155 0.600 2 0
190 156 146 0.600 2 0
191 147 157 0.600 2 0
192 158 147 0.600 2 0
193 148 159 0.600 2 0
194 160 148 0.600 2 0
195 149 161 0.600 2 0
196 162 149 0.600 2 0
197 150 163 0.600 2 0
198 164 150 0.600 2 0
199 165 166 1.034 5 0
200 166 167 1.034 5 0
201 167 168 1.034 5 0
202 168 169 1.034 5 0
203 169 170 1.034 5 0
204 170 171 1.034 5 0
205 171 96 1.034 5 0
206 165 172 0.600 2 0
207 173 165 0.600 2 0
208 166 174 0.600 2 0
209 175 166 0.600 2 0
210 167 176 0.600 2 0
211 177 167 0.600 2 0
212 168 178 0.600 2 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 5 of 56
Job No Sheet No Rev
6
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
213 179 168 0.600 2 0
214 169 180 0.600 2 0
215 181 169 0.600 2 0
216 170 182 0.600 2 0
217 183 170 0.600 2 0
218 171 184 0.600 2 0
219 185 171 0.600 2 0
220 186 187 0.872 5 0
221 187 188 0.872 5 0
222 188 116 0.872 5 0
223 186 189 0.600 2 0
225 187 191 0.600 2 0
227 188 193 0.600 2 0
229 195 196 0.862 5 0
230 196 197 0.862 5 0
231 197 198 0.862 5 0
232 198 115 0.862 5 0
233 198 199 0.600 2 0
234 200 198 0.600 2 0
235 197 201 0.600 2 0
236 202 197 0.600 2 0
237 196 203 0.600 2 0
238 204 196 0.600 2 0
239 195 205 0.600 2 0
240 206 195 0.600 2 0
241 207 208 0.862 5 0
242 208 209 0.862 5 0
243 209 210 0.862 5 0
244 210 114 0.862 5 0
245 210 211 0.600 2 0
246 212 210 0.600 2 0
247 209 213 0.600 2 0
248 214 209 0.600 2 0
249 208 215 0.600 2 0
250 216 208 0.600 2 0
251 207 217 0.600 2 0
252 218 207 0.600 2 0
253 219 220 1.013 5 0
254 220 221 1.012 5 0
255 221 222 1.013 5 0
256 222 223 1.012 5 0
257 223 224 1.012 5 0
258 224 225 1.013 5 0
259 225 106 1.013 5 0
260 226 227 1.013 5 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 6 of 56
Job No Sheet No Rev
7
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
261 227 228 1.012 5 0
262 228 229 1.013 5 0
263 229 230 1.013 5 0
264 230 231 1.012 5 0
265 231 232 1.013 5 0
266 232 108 1.012 5 0
267 233 234 1.012 5 0
268 234 235 1.012 5 0
269 235 236 1.012 5 0
270 236 237 1.013 5 0
271 237 238 1.012 5 0
272 238 239 1.012 5 0
273 239 107 1.013 5 0
274 219 240 0.600 2 0
275 241 219 0.600 2 0
276 220 242 0.600 2 0
277 243 220 0.600 2 0
278 221 244 0.600 2 0
279 245 221 0.600 2 0
280 222 246 0.600 2 0
281 247 222 0.600 2 0
282 223 248 0.600 2 0
283 249 223 0.600 2 0
284 224 250 0.600 2 0
285 251 224 0.600 2 0
286 225 252 0.600 2 0
287 253 225 0.600 2 0
288 233 254 0.600 2 0
289 255 233 0.600 2 0
290 234 256 0.600 2 0
291 257 234 0.600 2 0
292 235 258 0.600 2 0
293 259 235 0.600 2 0
294 236 260 0.600 2 0
295 261 236 0.600 2 0
296 237 262 0.600 2 0
297 263 237 0.600 2 0
298 238 264 0.600 2 0
299 265 238 0.600 2 0
300 239 266 0.600 2 0
301 267 239 0.600 2 0
302 226 268 0.600 2 0
303 269 226 0.600 2 0
304 227 270 0.600 2 0
305 271 227 0.600 2 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 7 of 56
Job No Sheet No Rev
8
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
306 228 272 0.600 2 0
307 273 228 0.600 2 0
308 229 274 0.600 2 0
309 275 229 0.600 2 0
310 230 276 0.600 2 0
311 277 230 0.600 2 0
312 231 278 0.600 2 0
313 279 231 0.600 2 0
314 232 280 0.600 2 0
315 281 232 0.600 2 0
316 282 283 0.835 5 0
317 283 284 0.835 5 0
318 284 117 0.835 5 0
319 282 327 0.600 2 0
320 286 282 0.600 2 0
321 283 328 0.600 2 0
322 288 283 0.600 2 0
323 284 329 0.600 2 0
324 290 284 0.600 2 0
325 291 292 1.071 5 0
326 292 293 1.071 5 0
327 293 294 1.071 5 0
328 294 295 1.071 5 0
329 295 296 1.071 5 0
330 296 315 0.471 5 0
331 291 297 0.600 2 0
332 298 291 0.600 2 0
333 292 299 0.600 2 0
334 300 292 0.600 2 0
335 293 301 0.600 2 0
336 302 293 0.600 2 0
337 294 303 0.600 2 0
338 304 294 0.600 2 0
339 295 305 0.600 2 0
340 306 295 0.600 2 0
341 296 307 0.600 2 0
342 308 296 0.600 2 0
343 309 102 0.835 5 0
344 310 309 0.835 5 0
345 311 310 0.835 5 0
346 311 336 2.182 2 0
347 310 337 1.932 2 0
348 309 338 1.682 2 0
349 312 90 3.750 7 0
350 312 217 0.862 6 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 8 of 56
Job No Sheet No Rev
9
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
351 217 215 0.862 6 0
352 215 213 0.862 6 0
353 213 211 0.862 6 0
354 313 291 0.471 5 0
355 211 349 0.262 6 0
356 314 94 0.600 5 0
357 314 206 0.862 6 0
358 206 204 0.862 6 0
359 204 202 0.862 6 0
360 202 200 0.862 6 0
361 315 115 0.600 5 0
362 200 348 0.262 6 0
363 312 240 1.013 8 0
364 240 242 1.013 8 0
365 242 244 1.012 8 0
366 244 246 1.013 8 0
367 246 248 1.012 8 0
368 248 250 1.012 8 0
369 250 252 1.013 8 0
370 316 106 0.600 5 0
371 252 316 1.013 8 0
372 317 104 0.600 5 0
373 317 241 1.013 8 0
374 241 243 1.013 8 0
375 243 245 1.012 8 0
376 245 247 1.013 8 0
377 247 249 1.012 8 0
378 249 251 1.012 8 0
379 251 253 1.013 8 0
380 318 98 0.150 5 0
381 253 318 1.013 8 0
382 314 131 1.013 8 0
383 131 133 1.013 8 0
384 133 135 1.012 8 0
385 135 137 1.013 8 0
386 137 139 1.012 8 0
387 139 141 1.012 8 0
388 141 143 1.013 8 0
389 319 95 0.600 5 0
390 143 319 1.013 8 0
391 320 110 0.250 5 0
392 320 130 1.013 8 0
393 130 132 1.013 8 0
394 132 134 1.012 8 0
395 134 136 1.013 8 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 9 of 56
Job No Sheet No Rev
10
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
396 136 138 1.012 8 0
397 138 140 1.012 8 0
398 140 142 1.013 8 0
399 321 111 0.250 5 0
400 142 321 1.013 8 0
401 322 99 0.150 5 0
402 322 269 1.012 8 0
403 318 255 1.012 8 0
404 323 100 0.150 5 0
405 323 286 0.835 6 0
406 269 271 1.013 8 0
407 271 273 1.012 8 0
408 273 275 1.013 8 0
409 275 277 1.013 8 0
410 277 279 1.012 8 0
411 279 281 1.013 8 0
412 281 323 1.012 8 0
413 255 257 1.012 8 0
414 257 259 1.012 8 0
415 259 261 1.012 8 0
416 261 263 1.013 8 0
417 263 265 1.012 8 0
418 265 267 1.012 8 0
419 267 322 1.013 8 0
420 286 288 0.835 6 0
421 288 290 0.835 6 0
422 290 324 0.835 6 0
423 325 107 0.600 5 0
424 325 268 1.012 8 0
425 316 254 1.012 8 0
426 326 108 0.600 5 0
427 327 311 1.450 2 0
428 326 327 0.835 6 0
429 268 270 1.013 8 0
430 270 272 1.012 8 0
431 272 274 1.013 8 0
432 274 276 1.013 8 0
433 276 278 1.012 8 0
434 278 280 1.013 8 0
435 280 326 1.012 8 0
436 254 256 1.012 8 0
437 256 258 1.012 8 0
438 258 260 1.012 8 0
439 260 262 1.013 8 0
440 262 264 1.012 8 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 10 of 56
Job No Sheet No Rev
11
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
441 264 266 1.012 8 0
442 266 325 1.013 8 0
443 328 310 1.450 2 0
444 327 328 0.835 6 0
445 329 309 1.450 2 0
446 328 329 0.835 6 0
447 330 117 0.600 5 0
448 329 330 0.835 6 0
449 324 117 0.600 5 0
450 321 151 1.017 8 0
451 331 112 0.250 5 0
452 331 172 1.034 8 0
453 332 113 0.100 5 0
454 332 189 0.872 6 0
455 151 153 1.017 8 0
456 153 155 1.017 8 0
457 155 157 1.017 8 0
458 157 159 1.017 8 0
459 159 161 1.017 8 0
460 161 163 1.017 8 0
461 163 331 1.017 8 0
462 172 174 1.034 8 0
463 174 176 1.034 8 0
464 176 178 1.034 8 0
465 178 180 1.034 8 0
466 180 182 1.034 8 0
467 182 184 1.034 8 0
468 184 332 1.034 8 0
469 189 191 0.872 6 0
470 191 193 0.872 6 0
471 193 333 0.872 6 0
472 319 152 1.017 8 0
473 334 101 0.600 5 0
474 334 173 1.034 8 0
475 335 96 0.600 5 0
476 336 186 0.600 2 0
477 335 336 0.872 6 0
478 152 154 1.017 8 0
479 154 156 1.017 8 0
480 156 158 1.017 8 0
481 158 160 1.017 8 0
482 160 162 1.017 8 0
483 162 164 1.017 8 0
484 164 334 1.017 8 0
485 173 175 1.034 8 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 11 of 56
Job No Sheet No Rev
12
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
486 175 177 1.034 8 0
487 177 179 1.034 8 0
488 179 181 1.034 8 0
489 181 183 1.034 8 0
490 183 185 1.034 8 0
491 185 335 1.034 8 0
492 337 187 0.600 2 0
493 336 337 0.872 6 0
494 338 188 0.600 2 0
495 337 338 0.872 6 0
496 339 116 0.600 5 0
497 338 339 0.872 6 0
498 116 333 0.600 5 0
499 317 218 0.862 6 0
500 218 216 0.862 6 0
501 216 214 0.862 6 0
502 214 212 0.862 6 0
503 212 340 0.862 6 0
504 340 114 0.600 2 0
505 320 205 0.862 6 0
506 205 203 0.862 6 0
507 203 201 0.862 6 0
508 201 199 0.862 6 0
509 199 341 0.862 6 0
510 115 341 0.600 5 0
511 342 115 0.600 5 0
512 343 341 0.600 6 0
513 344 313 0.600 6 0
514 345 114 0.600 5 0
515 346 340 0.600 6 0
516 345 344 0.600 6 0
517 298 300 1.071 6 0
518 300 302 1.071 6 0
519 302 304 1.071 6 0
520 304 306 1.071 6 0
521 306 308 1.071 6 0
522 308 347 0.471 6 0
523 344 298 0.471 6 0
524 347 342 0.600 6 0
525 346 345 0.600 5 0
526 342 343 0.600 5 0
527 297 299 1.071 6 0
528 299 301 1.071 6 0
529 301 303 1.071 6 0
530 303 305 1.071 6 0

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 12 of 56
Job No Sheet No Rev
13
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beams Cont...
Beam Node A Node B Length Property
(m) (degrees)
531 305 307 1.071 6 0
532 348 315 0.600 6 0
533 307 348 0.471 6 0
534 349 313 0.600 6 0
535 349 297 0.471 6 0

Supports
Node X Y Z rX rY rZ
(kN/mm) (kN/mm) (kN/mm) (kN-m/deg) (kN-m/deg) (kN-m/deg)
78 Fixed Fixed Fixed Fixed Fixed Fixed
79 Fixed Fixed Fixed Fixed Fixed Fixed
80 Fixed Fixed Fixed Fixed Fixed Fixed
82 Fixed Fixed Fixed Fixed Fixed Fixed
97 Fixed Fixed Fixed - - -
98 Fixed Fixed Fixed - - -
99 Fixed Fixed Fixed - - -
100 Fixed Fixed Fixed - - -

Seismic Loading : 1 EQ +X
Code Direction Factor

UBC X 1.000

Seismic Loading : 2 EQ +Z
Code Direction Factor

UBC Z 1.000

Selfweight : 3 DEAD LOAD


Direction Factor

Y -1.100

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 13 of 56
Job No Sheet No Rev
14
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 4 SDL


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
118 UNI kN/m GY -0.720 - - - -
119 UNI kN/m GY -0.720 - - - -
120 UNI kN/m GY -0.720 - - - -
UNI kN/m GY -3.432 - - - -
122 UNI kN/m GY -0.720 - - - -
123 UNI kN/m GY -0.720 - - - -
124 UNI kN/m GY -0.720 - - - -
UNI kN/m GY -3.432 - - - -
125 UNI kN/m GY -0.720 - - - -
128 UNI kN/m GY -0.720 - - - -
129 UNI kN/m GY -0.720 - - - -
132 UNI kN/m GY -3.432 - - - -
134 UNI kN/m GY -0.720 - - - -
135 UNI kN/m GY -0.720 - - - -
139 UNI kN/m GY -3.432 - - - -
140 UNI kN/m GY -0.720 - - - -
141 UNI kN/m GY -0.720 - - - -
142 UNI kN/m GY -0.720 - - - -
145 UNI kN/m GY -0.720 - - - -
146 UNI kN/m GY -0.720 - - - -
151 UNI kN/m GY -0.720 - - - -
153 UNI kN/m GY -1.002 - - - -
154 UNI kN/m GY -1.002 - - - -
157 UNI kN/m GY -0.720 - - - -
158 UNI kN/m GY -0.720 - - - -
159 UNI kN/m GY -0.720 - - - -
160 UNI kN/m GY -0.720 - - - -
161 UNI kN/m GY -0.720 - - - -
162 UNI kN/m GY -0.720 - - - -
163 UNI kN/m GY -0.720 - - - -
178 UNI kN/m GY -0.720 - - - -
179 UNI kN/m GY -0.720 - - - -
180 UNI kN/m GY -0.720 - - - -
181 UNI kN/m GY -0.720 - - - -
182 UNI kN/m GY -0.720 - - - -
183 UNI kN/m GY -0.720 - - - -
184 UNI kN/m GY -0.720 - - - -
199 UNI kN/m GY -0.720 - - - -
200 UNI kN/m GY -0.720 - - - -
201 UNI kN/m GY -0.720 - - - -
202 UNI kN/m GY -0.720 - - - -
203 UNI kN/m GY -0.720 - - - -
204 UNI kN/m GY -0.720 - - - -
205 UNI kN/m GY -0.720 - - - -
229 UNI kN/m GY -0.720 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 14 of 56
Job No Sheet No Rev
15
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 4 SDL Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
230 UNI kN/m GY -0.720 - - - -
231 UNI kN/m GY -0.720 - - - -
232 UNI kN/m GY -0.720 - - - -
241 UNI kN/m GY -0.720 - - - -
242 UNI kN/m GY -0.720 - - - -
243 UNI kN/m GY -0.720 - - - -
244 UNI kN/m GY -0.720 - - - -
253 UNI kN/m GY -0.720 - - - -
254 UNI kN/m GY -0.720 - - - -
255 UNI kN/m GY -0.720 - - - -
256 UNI kN/m GY -0.720 - - - -
257 UNI kN/m GY -0.720 - - - -
258 UNI kN/m GY -0.720 - - - -
259 UNI kN/m GY -0.720 - - - -
260 UNI kN/m GY -0.720 - - - -
261 UNI kN/m GY -0.720 - - - -
262 UNI kN/m GY -0.720 - - - -
263 UNI kN/m GY -0.720 - - - -
264 UNI kN/m GY -0.720 - - - -
265 UNI kN/m GY -0.720 - - - -
266 UNI kN/m GY -0.720 - - - -
267 UNI kN/m GY -0.720 - - - -
268 UNI kN/m GY -0.720 - - - -
269 UNI kN/m GY -0.720 - - - -
270 UNI kN/m GY -0.720 - - - -
271 UNI kN/m GY -0.720 - - - -
272 UNI kN/m GY -0.720 - - - -
273 UNI kN/m GY -0.720 - - - -
325 UNI kN/m GY -0.720 - - - -
326 UNI kN/m GY -0.720 - - - -
327 UNI kN/m GY -0.720 - - - -
328 UNI kN/m GY -0.720 - - - -
329 UNI kN/m GY -0.720 - - - -
330 UNI kN/m GY -0.720 - - - -
349 UNI kN/m GY -0.720 - - - -
350 UNI kN/m GY -0.720 - - - -
351 UNI kN/m GY -0.720 - - - -
352 UNI kN/m GY -0.720 - - - -
353 UNI kN/m GY -0.720 - - - -
354 UNI kN/m GY -0.720 - - - -
355 UNI kN/m GY -0.720 - - - -
356 UNI kN/m GY -0.720 - - - -
357 UNI kN/m GY -0.720 - - - -
358 UNI kN/m GY -0.720 - - - -
359 UNI kN/m GY -0.720 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 15 of 56
Job No Sheet No Rev
16
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 4 SDL Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
360 UNI kN/m GY -0.720 - - - -
361 UNI kN/m GY -0.720 - - - -
362 UNI kN/m GY -0.720 - - - -
363 UNI kN/m GY -0.720 - - - -
364 UNI kN/m GY -0.720 - - - -
365 UNI kN/m GY -0.720 - - - -
366 UNI kN/m GY -0.720 - - - -
367 UNI kN/m GY -0.720 - - - -
368 UNI kN/m GY -0.720 - - - -
369 UNI kN/m GY -0.720 - - - -
370 UNI kN/m GY -0.720 - - - -
371 UNI kN/m GY -0.720 - - - -
373 UNI kN/m GY -0.720 - - - -
374 UNI kN/m GY -0.720 - - - -
375 UNI kN/m GY -0.720 - - - -
376 UNI kN/m GY -0.720 - - - -
377 UNI kN/m GY -0.720 - - - -
378 UNI kN/m GY -0.720 - - - -
379 UNI kN/m GY -0.720 - - - -
381 UNI kN/m GY -0.720 - - - -
382 UNI kN/m GY -0.720 - - - -
383 UNI kN/m GY -0.720 - - - -
384 UNI kN/m GY -0.720 - - - -
385 UNI kN/m GY -0.720 - - - -
386 UNI kN/m GY -0.720 - - - -
387 UNI kN/m GY -0.720 - - - -
388 UNI kN/m GY -0.720 - - - -
389 UNI kN/m GY -0.720 - - - -
390 UNI kN/m GY -0.720 - - - -
392 UNI kN/m GY -0.720 - - - -
393 UNI kN/m GY -0.720 - - - -
394 UNI kN/m GY -0.720 - - - -
395 UNI kN/m GY -0.720 - - - -
396 UNI kN/m GY -0.720 - - - -
397 UNI kN/m GY -0.720 - - - -
398 UNI kN/m GY -0.720 - - - -
400 UNI kN/m GY -0.720 - - - -
402 UNI kN/m GY -0.720 - - - -
403 UNI kN/m GY -0.720 - - - -
404 UNI kN/m GY -3.432 - - - -
406 UNI kN/m GY -0.720 - - - -
407 UNI kN/m GY -0.720 - - - -
408 UNI kN/m GY -0.720 - - - -
409 UNI kN/m GY -0.720 - - - -
410 UNI kN/m GY -0.720 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 16 of 56
Job No Sheet No Rev
17
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 4 SDL Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
411 UNI kN/m GY -0.720 - - - -
412 UNI kN/m GY -0.720 - - - -
413 UNI kN/m GY -0.720 - - - -
414 UNI kN/m GY -0.720 - - - -
415 UNI kN/m GY -0.720 - - - -
416 UNI kN/m GY -0.720 - - - -
417 UNI kN/m GY -0.720 - - - -
418 UNI kN/m GY -0.720 - - - -
419 UNI kN/m GY -0.720 - - - -
423 UNI kN/m GY -0.720 - - - -
424 UNI kN/m GY -0.720 - - - -
425 UNI kN/m GY -0.720 - - - -
426 UNI kN/m GY -0.720 - - - -
UNI kN/m GY -3.432 - - - -
429 UNI kN/m GY -0.720 - - - -
430 UNI kN/m GY -0.720 - - - -
431 UNI kN/m GY -0.720 - - - -
432 UNI kN/m GY -0.720 - - - -
433 UNI kN/m GY -0.720 - - - -
434 UNI kN/m GY -0.720 - - - -
435 UNI kN/m GY -0.720 - - - -
436 UNI kN/m GY -0.720 - - - -
437 UNI kN/m GY -0.720 - - - -
438 UNI kN/m GY -0.720 - - - -
439 UNI kN/m GY -0.720 - - - -
440 UNI kN/m GY -0.720 - - - -
441 UNI kN/m GY -0.720 - - - -
442 UNI kN/m GY -0.720 - - - -
447 UNI kN/m GY -1.002 - - - -
450 UNI kN/m GY -0.720 - - - -
452 UNI kN/m GY -0.720 - - - -
453 UNI kN/m GY -3.432 - - - -
455 UNI kN/m GY -0.720 - - - -
456 UNI kN/m GY -0.720 - - - -
457 UNI kN/m GY -0.720 - - - -
458 UNI kN/m GY -0.720 - - - -
459 UNI kN/m GY -0.720 - - - -
460 UNI kN/m GY -0.720 - - - -
461 UNI kN/m GY -0.720 - - - -
462 UNI kN/m GY -0.720 - - - -
463 UNI kN/m GY -0.720 - - - -
464 UNI kN/m GY -0.720 - - - -
465 UNI kN/m GY -0.720 - - - -
466 UNI kN/m GY -0.720 - - - -
467 UNI kN/m GY -0.720 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 17 of 56
Job No Sheet No Rev
18
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 4 SDL Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
468 UNI kN/m GY -0.720 - - - -
472 UNI kN/m GY -0.720 - - - -
473 UNI kN/m GY -0.720 - - - -
474 UNI kN/m GY -0.720 - - - -
475 UNI kN/m GY -0.720 - - - -
UNI kN/m GY -3.432 - - - -
478 UNI kN/m GY -0.720 - - - -
479 UNI kN/m GY -0.720 - - - -
480 UNI kN/m GY -0.720 - - - -
481 UNI kN/m GY -0.720 - - - -
482 UNI kN/m GY -0.720 - - - -
483 UNI kN/m GY -0.720 - - - -
484 UNI kN/m GY -0.720 - - - -
485 UNI kN/m GY -0.720 - - - -
486 UNI kN/m GY -0.720 - - - -
487 UNI kN/m GY -0.720 - - - -
488 UNI kN/m GY -0.720 - - - -
489 UNI kN/m GY -0.720 - - - -
490 UNI kN/m GY -0.720 - - - -
491 UNI kN/m GY -0.720 - - - -
496 UNI kN/m GY -1.002 - - - -
498 UNI kN/m GY -1.002 - - - -
499 UNI kN/m GY -0.720 - - - -
500 UNI kN/m GY -0.720 - - - -
501 UNI kN/m GY -0.720 - - - -
502 UNI kN/m GY -0.720 - - - -
503 UNI kN/m GY -0.720 - - - -
505 UNI kN/m GY -0.720 - - - -
506 UNI kN/m GY -0.720 - - - -
507 UNI kN/m GY -0.720 - - - -
508 UNI kN/m GY -0.720 - - - -
509 UNI kN/m GY -0.720 - - - -
510 UNI kN/m GY -0.720 - - - -
516 UNI kN/m GY -0.720 - - - -
517 UNI kN/m GY -0.720 - - - -
518 UNI kN/m GY -0.720 - - - -
519 UNI kN/m GY -0.720 - - - -
520 UNI kN/m GY -0.720 - - - -
521 UNI kN/m GY -0.720 - - - -
522 UNI kN/m GY -0.720 - - - -
523 UNI kN/m GY -0.720 - - - -
524 UNI kN/m GY -0.720 - - - -
526 UNI kN/m GY -0.720 - - - -
527 UNI kN/m GY -0.720 - - - -
528 UNI kN/m GY -0.720 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 18 of 56
Job No Sheet No Rev
19
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 4 SDL Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
529 UNI kN/m GY -0.720 - - - -
530 UNI kN/m GY -0.720 - - - -
531 UNI kN/m GY -0.720 - - - -
532 UNI kN/m GY -0.720 - - - -
533 UNI kN/m GY -0.720 - - - -
534 UNI kN/m GY -0.720 - - - -
535 UNI kN/m GY -0.720 - - - -

Beam Loads : 5 LIVE LOAD


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
118 UNI kN/m GY -0.900 - - - -
119 UNI kN/m GY -0.900 - - - -
120 UNI kN/m GY -0.900 - - - -
UNI kN/m GY -4.290 - - - -
122 UNI kN/m GY -0.900 - - - -
123 UNI kN/m GY -0.900 - - - -
124 UNI kN/m GY -0.900 - - - -
UNI kN/m GY -4.290 - - - -
125 UNI kN/m GY -0.900 - - - -
128 UNI kN/m GY -0.900 - - - -
129 UNI kN/m GY -0.900 - - - -
132 UNI kN/m GY -4.290 - - - -
134 UNI kN/m GY -0.900 - - - -
135 UNI kN/m GY -0.900 - - - -
139 UNI kN/m GY -4.290 - - - -
140 UNI kN/m GY -0.900 - - - -
141 UNI kN/m GY -0.900 - - - -
142 UNI kN/m GY -0.900 - - - -
145 UNI kN/m GY -0.900 - - - -
146 UNI kN/m GY -0.900 - - - -
151 UNI kN/m GY -0.900 - - - -
153 UNI kN/m GY -1.253 - - - -
154 UNI kN/m GY -1.253 - - - -
157 UNI kN/m GY -0.900 - - - -
158 UNI kN/m GY -0.900 - - - -
159 UNI kN/m GY -0.900 - - - -
160 UNI kN/m GY -0.900 - - - -
161 UNI kN/m GY -0.900 - - - -
162 UNI kN/m GY -0.900 - - - -
163 UNI kN/m GY -0.900 - - - -
178 UNI kN/m GY -0.900 - - - -
179 UNI kN/m GY -0.900 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 19 of 56
Job No Sheet No Rev
20
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 5 LIVE LOAD Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
180 UNI kN/m GY -0.900 - - - -
181 UNI kN/m GY -0.900 - - - -
182 UNI kN/m GY -0.900 - - - -
183 UNI kN/m GY -0.900 - - - -
184 UNI kN/m GY -0.900 - - - -
199 UNI kN/m GY -0.900 - - - -
200 UNI kN/m GY -0.900 - - - -
201 UNI kN/m GY -0.900 - - - -
202 UNI kN/m GY -0.900 - - - -
203 UNI kN/m GY -0.900 - - - -
204 UNI kN/m GY -0.900 - - - -
205 UNI kN/m GY -0.900 - - - -
229 UNI kN/m GY -0.900 - - - -
230 UNI kN/m GY -0.900 - - - -
231 UNI kN/m GY -0.900 - - - -
232 UNI kN/m GY -0.900 - - - -
241 UNI kN/m GY -0.900 - - - -
242 UNI kN/m GY -0.900 - - - -
243 UNI kN/m GY -0.900 - - - -
244 UNI kN/m GY -0.900 - - - -
253 UNI kN/m GY -0.900 - - - -
254 UNI kN/m GY -0.900 - - - -
255 UNI kN/m GY -0.900 - - - -
256 UNI kN/m GY -0.900 - - - -
257 UNI kN/m GY -0.900 - - - -
258 UNI kN/m GY -0.900 - - - -
259 UNI kN/m GY -0.900 - - - -
260 UNI kN/m GY -0.900 - - - -
261 UNI kN/m GY -0.900 - - - -
262 UNI kN/m GY -0.900 - - - -
263 UNI kN/m GY -0.900 - - - -
264 UNI kN/m GY -0.900 - - - -
265 UNI kN/m GY -0.900 - - - -
266 UNI kN/m GY -0.900 - - - -
267 UNI kN/m GY -0.900 - - - -
268 UNI kN/m GY -0.900 - - - -
269 UNI kN/m GY -0.900 - - - -
270 UNI kN/m GY -0.900 - - - -
271 UNI kN/m GY -0.900 - - - -
272 UNI kN/m GY -0.900 - - - -
273 UNI kN/m GY -0.900 - - - -
325 UNI kN/m GY -0.900 - - - -
326 UNI kN/m GY -0.900 - - - -
327 UNI kN/m GY -0.900 - - - -
328 UNI kN/m GY -0.900 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 20 of 56
Job No Sheet No Rev
21
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 5 LIVE LOAD Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
329 UNI kN/m GY -0.900 - - - -
330 UNI kN/m GY -0.900 - - - -
349 UNI kN/m GY -0.900 - - - -
350 UNI kN/m GY -0.900 - - - -
351 UNI kN/m GY -0.900 - - - -
352 UNI kN/m GY -0.900 - - - -
353 UNI kN/m GY -0.900 - - - -
354 UNI kN/m GY -0.900 - - - -
355 UNI kN/m GY -0.900 - - - -
356 UNI kN/m GY -0.900 - - - -
357 UNI kN/m GY -0.900 - - - -
358 UNI kN/m GY -0.900 - - - -
359 UNI kN/m GY -0.900 - - - -
360 UNI kN/m GY -0.900 - - - -
361 UNI kN/m GY -0.900 - - - -
362 UNI kN/m GY -0.900 - - - -
363 UNI kN/m GY -0.900 - - - -
364 UNI kN/m GY -0.900 - - - -
365 UNI kN/m GY -0.900 - - - -
366 UNI kN/m GY -0.900 - - - -
367 UNI kN/m GY -0.900 - - - -
368 UNI kN/m GY -0.900 - - - -
369 UNI kN/m GY -0.900 - - - -
370 UNI kN/m GY -0.900 - - - -
371 UNI kN/m GY -0.900 - - - -
373 UNI kN/m GY -0.900 - - - -
374 UNI kN/m GY -0.900 - - - -
375 UNI kN/m GY -0.900 - - - -
376 UNI kN/m GY -0.900 - - - -
377 UNI kN/m GY -0.900 - - - -
378 UNI kN/m GY -0.900 - - - -
379 UNI kN/m GY -0.900 - - - -
381 UNI kN/m GY -0.900 - - - -
382 UNI kN/m GY -0.900 - - - -
383 UNI kN/m GY -0.900 - - - -
384 UNI kN/m GY -0.900 - - - -
385 UNI kN/m GY -0.900 - - - -
386 UNI kN/m GY -0.900 - - - -
387 UNI kN/m GY -0.900 - - - -
388 UNI kN/m GY -0.900 - - - -
389 UNI kN/m GY -0.900 - - - -
390 UNI kN/m GY -0.900 - - - -
392 UNI kN/m GY -0.900 - - - -
393 UNI kN/m GY -0.900 - - - -
394 UNI kN/m GY -0.900 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 21 of 56
Job No Sheet No Rev
22
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 5 LIVE LOAD Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
395 UNI kN/m GY -0.900 - - - -
396 UNI kN/m GY -0.900 - - - -
397 UNI kN/m GY -0.900 - - - -
398 UNI kN/m GY -0.900 - - - -
400 UNI kN/m GY -0.900 - - - -
402 UNI kN/m GY -0.900 - - - -
403 UNI kN/m GY -0.900 - - - -
404 UNI kN/m GY -4.290 - - - -
406 UNI kN/m GY -0.900 - - - -
407 UNI kN/m GY -0.900 - - - -
408 UNI kN/m GY -0.900 - - - -
409 UNI kN/m GY -0.900 - - - -
410 UNI kN/m GY -0.900 - - - -
411 UNI kN/m GY -0.900 - - - -
412 UNI kN/m GY -0.900 - - - -
413 UNI kN/m GY -0.900 - - - -
414 UNI kN/m GY -0.900 - - - -
415 UNI kN/m GY -0.900 - - - -
416 UNI kN/m GY -0.900 - - - -
417 UNI kN/m GY -0.900 - - - -
418 UNI kN/m GY -0.900 - - - -
419 UNI kN/m GY -0.900 - - - -
423 UNI kN/m GY -0.900 - - - -
424 UNI kN/m GY -0.900 - - - -
425 UNI kN/m GY -0.900 - - - -
426 UNI kN/m GY -0.900 - - - -
UNI kN/m GY -4.290 - - - -
429 UNI kN/m GY -0.900 - - - -
430 UNI kN/m GY -0.900 - - - -
431 UNI kN/m GY -0.900 - - - -
432 UNI kN/m GY -0.900 - - - -
433 UNI kN/m GY -0.900 - - - -
434 UNI kN/m GY -0.900 - - - -
435 UNI kN/m GY -0.900 - - - -
436 UNI kN/m GY -0.900 - - - -
437 UNI kN/m GY -0.900 - - - -
438 UNI kN/m GY -0.900 - - - -
439 UNI kN/m GY -0.900 - - - -
440 UNI kN/m GY -0.900 - - - -
441 UNI kN/m GY -0.900 - - - -
442 UNI kN/m GY -0.900 - - - -
447 UNI kN/m GY -1.253 - - - -
450 UNI kN/m GY -0.900 - - - -
452 UNI kN/m GY -0.900 - - - -
453 UNI kN/m GY -4.290 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 22 of 56
Job No Sheet No Rev
23
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 5 LIVE LOAD Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
455 UNI kN/m GY -0.900 - - - -
456 UNI kN/m GY -0.900 - - - -
457 UNI kN/m GY -0.900 - - - -
458 UNI kN/m GY -0.900 - - - -
459 UNI kN/m GY -0.900 - - - -
460 UNI kN/m GY -0.900 - - - -
461 UNI kN/m GY -0.900 - - - -
462 UNI kN/m GY -0.900 - - - -
463 UNI kN/m GY -0.900 - - - -
464 UNI kN/m GY -0.900 - - - -
465 UNI kN/m GY -0.900 - - - -
466 UNI kN/m GY -0.900 - - - -
467 UNI kN/m GY -0.900 - - - -
468 UNI kN/m GY -0.900 - - - -
472 UNI kN/m GY -0.900 - - - -
473 UNI kN/m GY -0.900 - - - -
474 UNI kN/m GY -0.900 - - - -
475 UNI kN/m GY -0.900 - - - -
UNI kN/m GY -4.290 - - - -
478 UNI kN/m GY -0.900 - - - -
479 UNI kN/m GY -0.900 - - - -
480 UNI kN/m GY -0.900 - - - -
481 UNI kN/m GY -0.900 - - - -
482 UNI kN/m GY -0.900 - - - -
483 UNI kN/m GY -0.900 - - - -
484 UNI kN/m GY -0.900 - - - -
485 UNI kN/m GY -0.900 - - - -
486 UNI kN/m GY -0.900 - - - -
487 UNI kN/m GY -0.900 - - - -
488 UNI kN/m GY -0.900 - - - -
489 UNI kN/m GY -0.900 - - - -
490 UNI kN/m GY -0.900 - - - -
491 UNI kN/m GY -0.900 - - - -
496 UNI kN/m GY -1.253 - - - -
498 UNI kN/m GY -1.253 - - - -
499 UNI kN/m GY -0.900 - - - -
500 UNI kN/m GY -0.900 - - - -
501 UNI kN/m GY -0.900 - - - -
502 UNI kN/m GY -0.900 - - - -
503 UNI kN/m GY -0.900 - - - -
505 UNI kN/m GY -0.900 - - - -
506 UNI kN/m GY -0.900 - - - -
507 UNI kN/m GY -0.900 - - - -
508 UNI kN/m GY -0.900 - - - -
509 UNI kN/m GY -0.900 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 23 of 56
Job No Sheet No Rev
24
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 5 LIVE LOAD Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
510 UNI kN/m GY -0.900 - - - -
516 UNI kN/m GY -0.900 - - - -
517 UNI kN/m GY -0.900 - - - -
518 UNI kN/m GY -0.900 - - - -
519 UNI kN/m GY -0.900 - - - -
520 UNI kN/m GY -0.900 - - - -
521 UNI kN/m GY -0.900 - - - -
522 UNI kN/m GY -0.900 - - - -
523 UNI kN/m GY -0.900 - - - -
524 UNI kN/m GY -0.900 - - - -
526 UNI kN/m GY -0.900 - - - -
527 UNI kN/m GY -0.900 - - - -
528 UNI kN/m GY -0.900 - - - -
529 UNI kN/m GY -0.900 - - - -
530 UNI kN/m GY -0.900 - - - -
531 UNI kN/m GY -0.900 - - - -
532 UNI kN/m GY -0.900 - - - -
533 UNI kN/m GY -0.900 - - - -
534 UNI kN/m GY -0.900 - - - -
535 UNI kN/m GY -0.900 - - - -

Beam Loads : 6 WL +X PRESSURE


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
114 UNI kN/m GX 1.800 - - - -
115 UNI kN/m GX 1.800 - - - -
116 UNI kN/m GX 1.800 - - - -
117 UNI kN/m GX 1.800 - - - -
118 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 7.000 - - - -
119 UNI kN/m GY 9.150 - - - -
UNI kN/m GY 4.800 - - - -
120 UNI kN/m GY 2.930 - - - -
UNI kN/m GY 4.800 - - - -
122 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 9.150 - - - -
123 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 9.250 - - - -
124 UNI kN/m GY 2.930 - - - -
UNI kN/m GY 4.800 - - - -
125 UNI kN/m GY 9.250 - - - -
UNI kN/m GY 4.800 - - - -
128 UNI kN/m GY 4.800 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 24 of 56
Job No Sheet No Rev
25
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 6 WL +X PRESSURE Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
128 UNI kN/m GY 7.000 - - - -
129 UNI kN/m GY 4.800 - - - -
130 UNI kN/m GY 9.150 - - - -
131 UNI kN/m GY 9.250 - - - -
132 UNI kN/m GY 2.930 - - - -
134 UNI kN/m GY 4.800 - - - -
135 UNI kN/m GY 4.800 - - - -
136 UNI kN/m GY 7.000 - - - -
137 UNI kN/m GY 9.150 - - - -
138 UNI kN/m GY 9.250 - - - -
139 UNI kN/m GY 2.930 - - - -
140 UNI kN/m GY 4.800 - - - -
141 UNI kN/m GY 4.800 - - - -
142 UNI kN/m GY 4.800 - - - -
145 UNI kN/m GY 4.800 - - - -
146 UNI kN/m GY 4.800 - - - -
151 UNI kN/m GY 5.930 - - - -
UNI kN/m GY 4.800 - - - -
153 UNI kN/m GY 0.860 - - - -
154 UNI kN/m GY 0.860 - - - -
157 UNI kN/m GY 4.800 - - - -
158 UNI kN/m GY 4.800 - - - -
159 UNI kN/m GY 4.800 - - - -
160 UNI kN/m GY 4.800 - - - -
161 UNI kN/m GY 4.800 - - - -
162 UNI kN/m GY 4.800 - - - -
163 UNI kN/m GY 4.800 - - - -
178 UNI kN/m GY 4.800 - - - -
179 UNI kN/m GY 4.800 - - - -
180 UNI kN/m GY 4.800 - - - -
181 UNI kN/m GY 4.800 - - - -
182 UNI kN/m GY 4.800 - - - -
183 UNI kN/m GY 4.800 - - - -
184 UNI kN/m GY 4.800 - - - -
199 UNI kN/m GY 4.800 - - - -
200 UNI kN/m GY 4.800 - - - -
201 UNI kN/m GY 4.800 - - - -
202 UNI kN/m GY 4.800 - - - -
203 UNI kN/m GY 4.800 - - - -
204 UNI kN/m GY 4.800 - - - -
205 UNI kN/m GY 4.800 - - - -
229 UNI kN/m GY 4.800 - - - -
230 UNI kN/m GY 4.800 - - - -
231 UNI kN/m GY 4.800 - - - -
232 UNI kN/m GY 4.800 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 25 of 56
Job No Sheet No Rev
26
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 6 WL +X PRESSURE Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
241 UNI kN/m GY 4.800 - - - -
242 UNI kN/m GY 4.800 - - - -
243 UNI kN/m GY 4.800 - - - -
244 UNI kN/m GY 4.800 - - - -
253 UNI kN/m GY 4.800 - - - -
254 UNI kN/m GY 4.800 - - - -
255 UNI kN/m GY 4.800 - - - -
256 UNI kN/m GY 4.800 - - - -
257 UNI kN/m GY 4.800 - - - -
258 UNI kN/m GY 4.800 - - - -
259 UNI kN/m GY 4.800 - - - -
260 UNI kN/m GY 4.800 - - - -
261 UNI kN/m GY 4.800 - - - -
262 UNI kN/m GY 4.800 - - - -
263 UNI kN/m GY 4.800 - - - -
264 UNI kN/m GY 4.800 - - - -
265 UNI kN/m GY 4.800 - - - -
266 UNI kN/m GY 4.800 - - - -
267 UNI kN/m GY 4.800 - - - -
268 UNI kN/m GY 4.800 - - - -
269 UNI kN/m GY 4.800 - - - -
270 UNI kN/m GY 4.800 - - - -
271 UNI kN/m GY 4.800 - - - -
272 UNI kN/m GY 4.800 - - - -
273 UNI kN/m GY 4.800 - - - -
325 UNI kN/m GY 5.930 - - - -
UNI kN/m GY 4.800 - - - -
326 UNI kN/m GY 4.310 - - - -
UNI kN/m GY 4.800 - - - -
327 UNI kN/m GY 4.310 - - - -
UNI kN/m GY 4.800 - - - -
328 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 4.310 - - - -
329 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 5.930 - - - -
330 UNI kN/m GY 5.930 - - - -
UNI kN/m GY 4.800 - - - -
349 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 7.000 - - - -
354 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 5.930 - - - -
356 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 7.000 - - - -
361 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 5.930 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 26 of 56
Job No Sheet No Rev
27
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 6 WL +X PRESSURE Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
370 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 9.150 - - - -
372 UNI kN/m GY 7.000 - - - -
389 UNI kN/m GY 9.150 - - - -
UNI kN/m GY 4.800 - - - -
391 UNI kN/m GY 7.000 - - - -
399 UNI kN/m GY 9.150 - - - -
423 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 9.250 - - - -
426 UNI kN/m GY 2.930 - - - -
UNI kN/m GY 4.800 - - - -
447 UNI kN/m GY 0.860 - - - -
451 UNI kN/m GY 9.250 - - - -
453 UNI kN/m GY 2.930 - - - -
473 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 9.250 - - - -
475 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 2.930 - - - -
496 UNI kN/m GY 0.860 - - - -
498 UNI kN/m GY 0.860 - - - -
510 UNI kN/m GY 4.800 - - - -
UNI kN/m GY 5.930 - - - -

Beam Loads : 7 WL -X SUCTION


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
114 UNI kN/m GX 1.800 - - - -
115 UNI kN/m GX 1.800 - - - -
116 UNI kN/m GX 1.800 - - - -
117 UNI kN/m GX 1.800 - - - -
118 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.880 - - - -
119 UNI kN/m GY -5.075 - - - -
UNI kN/m GY -1.500 - - - -
120 UNI kN/m GY -3.660 - - - -
UNI kN/m GY -1.500 - - - -
121 UNI kN/m GY -3.880 - - - -
122 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.075 - - - -
123 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.134 - - - -
124 UNI kN/m GY -3.660 - - - -
UNI kN/m GY -1.500 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 27 of 56
Job No Sheet No Rev
28
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 7 WL -X SUCTION Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
125 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.134 - - - -
128 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.880 - - - -
129 UNI kN/m GY -1.500 - - - -
130 UNI kN/m GY -5.075 - - - -
131 UNI kN/m GY -5.134 - - - -
132 UNI kN/m GY -3.660 - - - -
134 UNI kN/m GY -1.500 - - - -
135 UNI kN/m GY -1.500 - - - -
136 UNI kN/m GY -3.880 - - - -
137 UNI kN/m GY -5.075 - - - -
138 UNI kN/m GY -5.134 - - - -
139 UNI kN/m GY -3.660 - - - -
140 UNI kN/m GY -1.500 - - - -
141 UNI kN/m GY -1.500 - - - -
142 UNI kN/m GY -1.500 - - - -
145 UNI kN/m GY -1.500 - - - -
146 UNI kN/m GY -1.500 - - - -
151 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
153 UNI kN/m GY -1.070 - - - -
154 UNI kN/m GY -1.070 - - - -
157 UNI kN/m GY -1.500 - - - -
158 UNI kN/m GY -1.500 - - - -
159 UNI kN/m GY -1.500 - - - -
160 UNI kN/m GY -1.500 - - - -
161 UNI kN/m GY -1.500 - - - -
162 UNI kN/m GY -1.500 - - - -
163 UNI kN/m GY -1.500 - - - -
178 UNI kN/m GY -1.500 - - - -
179 UNI kN/m GY -1.500 - - - -
180 UNI kN/m GY -1.500 - - - -
181 UNI kN/m GY -1.500 - - - -
182 UNI kN/m GY -1.500 - - - -
183 UNI kN/m GY -1.500 - - - -
184 UNI kN/m GY -1.500 - - - -
199 UNI kN/m GY -1.500 - - - -
200 UNI kN/m GY -1.500 - - - -
201 UNI kN/m GY -1.500 - - - -
202 UNI kN/m GY -1.500 - - - -
203 UNI kN/m GY -1.500 - - - -
204 UNI kN/m GY -1.500 - - - -
205 UNI kN/m GY -1.500 - - - -
229 UNI kN/m GY -1.500 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 28 of 56
Job No Sheet No Rev
29
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 7 WL -X SUCTION Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
230 UNI kN/m GY -1.500 - - - -
231 UNI kN/m GY -1.500 - - - -
232 UNI kN/m GY -1.500 - - - -
241 UNI kN/m GY -1.500 - - - -
242 UNI kN/m GY -1.500 - - - -
243 UNI kN/m GY -1.500 - - - -
244 UNI kN/m GY -1.500 - - - -
253 UNI kN/m GY -1.500 - - - -
254 UNI kN/m GY -1.500 - - - -
255 UNI kN/m GY -1.500 - - - -
256 UNI kN/m GY -1.500 - - - -
257 UNI kN/m GY -1.500 - - - -
258 UNI kN/m GY -1.500 - - - -
259 UNI kN/m GY -1.500 - - - -
260 UNI kN/m GY -1.500 - - - -
261 UNI kN/m GY -1.500 - - - -
262 UNI kN/m GY -1.500 - - - -
263 UNI kN/m GY -1.500 - - - -
264 UNI kN/m GY -1.500 - - - -
265 UNI kN/m GY -1.500 - - - -
266 UNI kN/m GY -1.500 - - - -
267 UNI kN/m GY -1.500 - - - -
268 UNI kN/m GY -1.500 - - - -
269 UNI kN/m GY -1.500 - - - -
270 UNI kN/m GY -1.500 - - - -
271 UNI kN/m GY -1.500 - - - -
272 UNI kN/m GY -1.500 - - - -
273 UNI kN/m GY -1.500 - - - -
325 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
326 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -1.350 - - - -
327 UNI kN/m GY -1.350 - - - -
UNI kN/m GY -1.500 - - - -
328 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -1.350 - - - -
329 UNI kN/m GY -0.625 - - - -
UNI kN/m GY -1.500 - - - -
330 UNI kN/m GY -0.625 - - - -
UNI kN/m GY -1.500 - - - -
349 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.880 - - - -
354 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
356 UNI kN/m GY -3.880 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 29 of 56
Job No Sheet No Rev
30
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 7 WL -X SUCTION Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
356 UNI kN/m GY -1.500 - - - -
361 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
370 UNI kN/m GY -5.075 - - - -
UNI kN/m GY -1.500 - - - -
372 UNI kN/m GY -3.880 - - - -
380 UNI kN/m GY -5.075 - - - -
389 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.075 - - - -
391 UNI kN/m GY -3.880 - - - -
399 UNI kN/m GY -5.075 - - - -
401 UNI kN/m GY -5.134 - - - -
404 UNI kN/m GY -3.660 - - - -
423 UNI kN/m GY -5.134 - - - -
UNI kN/m GY -1.500 - - - -
426 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.660 - - - -
447 UNI kN/m GY -1.070 - - - -
451 UNI kN/m GY -5.134 - - - -
453 UNI kN/m GY -3.660 - - - -
473 UNI kN/m GY -5.134 - - - -
UNI kN/m GY -1.500 - - - -
475 UNI kN/m GY -3.660 - - - -
UNI kN/m GY -1.500 - - - -
496 UNI kN/m GY -1.070 - - - -
498 UNI kN/m GY -1.070 - - - -
510 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -

Beam Loads : 8 WL +Z PRESSURE


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
114 UNI kN/m GZ -3.330 - - - -
115 UNI kN/m GZ -11.400 - - - -
116 UNI kN/m GZ -11.400 - - - -
117 UNI kN/m GZ -3.330 - - - -
118 UNI kN/m GY 9.130 - - - -
UNI kN/m GY 17.100 - - - -
UNI kN/m GY 4.200 - - - -
119 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 9.245 - - - -
UNI kN/m GY 16.430 - - - -
120 UNI kN/m GY 16.100 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 30 of 56
Job No Sheet No Rev
31
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 8 WL +Z PRESSURE Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
120 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 6.590 - - - -
121 UNI kN/m GY 9.130 - - - -
122 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 9.245 - - - -
123 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 9.250 - - - -
124 UNI kN/m GY 6.590 - - - -
UNI kN/m GY 4.200 - - - -
125 UNI kN/m GY 16.430 - - - -
UNI kN/m GY 9.250 - - - -
UNI kN/m GY 4.200 - - - -
128 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 9.130 - - - -
129 UNI kN/m GY 4.200 - - - -
130 UNI kN/m GY 9.245 - - - -
131 UNI kN/m GY 9.250 - - - -
132 UNI kN/m GY 6.590 - - - -
134 UNI kN/m GY 4.200 - - - -
135 UNI kN/m GY 4.200 - - - -
136 UNI kN/m GY 9.130 - - - -
UNI kN/m GY 17.100 - - - -
137 UNI kN/m GY 9.245 - - - -
UNI kN/m GY 16.430 - - - -
138 UNI kN/m GY 9.250 - - - -
UNI kN/m GY 16.430 - - - -
139 UNI kN/m GY 6.590 - - - -
UNI kN/m GY 16.100 - - - -
140 UNI kN/m GY 4.200 - - - -
141 UNI kN/m GY 4.200 - - - -
142 UNI kN/m GY 4.200 - - - -
145 UNI kN/m GY 4.200 - - - -
146 UNI kN/m GY 4.200 - - - -
151 UNI kN/m GY 1.125 - - - -
UNI kN/m GY 4.200 - - - -
153 UNI kN/m GY 1.920 - - - -
UNI kN/m GY 4.700 - - - -
154 UNI kN/m GY 1.920 - - - -
157 UNI kN/m GY 4.200 - - - -
158 UNI kN/m GY 4.200 - - - -
159 UNI kN/m GY 4.200 - - - -
160 UNI kN/m GY 4.200 - - - -
161 UNI kN/m GY 4.200 - - - -
162 UNI kN/m GY 4.200 - - - -
163 UNI kN/m GY 4.200 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 31 of 56
Job No Sheet No Rev
32
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 8 WL +Z PRESSURE Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
178 UNI kN/m GY 4.200 - - - -
179 UNI kN/m GY 4.200 - - - -
180 UNI kN/m GY 4.200 - - - -
181 UNI kN/m GY 4.200 - - - -
182 UNI kN/m GY 4.200 - - - -
183 UNI kN/m GY 4.200 - - - -
184 UNI kN/m GY 4.200 - - - -
199 UNI kN/m GY 4.200 - - - -
200 UNI kN/m GY 4.200 - - - -
201 UNI kN/m GY 4.200 - - - -
202 UNI kN/m GY 4.200 - - - -
203 UNI kN/m GY 4.200 - - - -
204 UNI kN/m GY 4.200 - - - -
205 UNI kN/m GY 4.200 - - - -
229 UNI kN/m GY 4.200 - - - -
230 UNI kN/m GY 4.200 - - - -
231 UNI kN/m GY 4.200 - - - -
232 UNI kN/m GY 4.200 - - - -
241 UNI kN/m GY 4.200 - - - -
242 UNI kN/m GY 4.200 - - - -
243 UNI kN/m GY 4.200 - - - -
244 UNI kN/m GY 4.200 - - - -
253 UNI kN/m GY 4.200 - - - -
254 UNI kN/m GY 4.200 - - - -
255 UNI kN/m GY 4.200 - - - -
256 UNI kN/m GY 4.200 - - - -
257 UNI kN/m GY 4.200 - - - -
258 UNI kN/m GY 4.200 - - - -
259 UNI kN/m GY 4.200 - - - -
260 UNI kN/m GY 4.200 - - - -
261 UNI kN/m GY 4.200 - - - -
262 UNI kN/m GY 4.200 - - - -
263 UNI kN/m GY 4.200 - - - -
264 UNI kN/m GY 4.200 - - - -
265 UNI kN/m GY 4.200 - - - -
266 UNI kN/m GY 4.200 - - - -
267 UNI kN/m GY 4.200 - - - -
268 UNI kN/m GY 4.200 - - - -
269 UNI kN/m GY 4.200 - - - -
270 UNI kN/m GY 4.200 - - - -
271 UNI kN/m GY 4.200 - - - -
272 UNI kN/m GY 4.200 - - - -
273 UNI kN/m GY 4.200 - - - -
325 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 1.125 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 32 of 56
Job No Sheet No Rev
33
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 8 WL +Z PRESSURE Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
326 UNI kN/m GY 2.430 - - - -
UNI kN/m GY 4.200 - - - -
327 UNI kN/m GY 2.430 - - - -
UNI kN/m GY 4.200 - - - -
328 UNI kN/m GY 5.930 - - - -
UNI kN/m GY 4.200 - - - -
UNI kN/m GY 2.430 - - - -
329 UNI kN/m GY 1.125 - - - -
UNI kN/m GY 5.930 - - - -
UNI kN/m GY 4.200 - - - -
330 UNI kN/m GY 1.125 - - - -
UNI kN/m GY 5.930 - - - -
UNI kN/m GY 4.200 - - - -
349 UNI kN/m GY 9.130 - - - -
UNI kN/m GY 4.200 - - - -
354 UNI kN/m GY 1.125 - - - -
UNI kN/m GY 4.200 - - - -
356 UNI kN/m GY 9.130 - - - -
UNI kN/m GY 4.200 - - - -
UNI kN/m GY 17.100 - - - -
361 UNI kN/m GY 1.125 - - - -
UNI kN/m GY 4.200 - - - -
UNI kN/m GY 5.930 - - - -
370 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 9.245 - - - -
372 UNI kN/m GY 9.130 - - - -
380 UNI kN/m GY 9.245 - - - -
389 UNI kN/m GY 9.245 - - - -
UNI kN/m GY 4.200 - - - -
UNI kN/m GY 16.430 - - - -
391 UNI kN/m GY 17.100 - - - -
UNI kN/m GY 9.130 - - - -
399 UNI kN/m GY 16.430 - - - -
UNI kN/m GY 9.245 - - - -
401 UNI kN/m GY 9.250 - - - -
404 UNI kN/m GY 6.590 - - - -
423 UNI kN/m GY 4.200 - - - -
UNI kN/m GY 9.250 - - - -
426 UNI kN/m GY 6.590 - - - -
UNI kN/m GY 4.200 - - - -
447 UNI kN/m GY 1.920 - - - -
451 UNI kN/m GY 16.430 - - - -
UNI kN/m GY 9.250 - - - -
453 UNI kN/m GY 6.590 - - - -
UNI kN/m GY 16.100 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 33 of 56
Job No Sheet No Rev
34
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 8 WL +Z PRESSURE Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
473 UNI kN/m GY 16.430 - - - -
UNI kN/m GY 4.200 - - - -
UNI kN/m GY 9.250 - - - -
475 UNI kN/m GY 6.590 - - - -
UNI kN/m GY 4.200 - - - -
UNI kN/m GY 16.100 - - - -
496 UNI kN/m GY 1.920 - - - -
UNI kN/m GY 4.700 - - - -
498 UNI kN/m GY 1.920 - - - -
UNI kN/m GY 4.700 - - - -
510 UNI kN/m GY 5.930 - - - -
UNI kN/m GY 1.125 - - - -
UNI kN/m GY 4.200 - - - -

Beam Loads : 9 WL -Z SUCTION


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
114 UNI kN/m GZ -10.100 - - - -
115 UNI kN/m GZ -19.660 - - - -
116 UNI kN/m GZ -19.660 - - - -
117 UNI kN/m GZ -10.100 - - - -
118 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.880 - - - -
119 UNI kN/m GY -5.075 - - - -
UNI kN/m GY -1.500 - - - -
120 UNI kN/m GY -3.660 - - - -
UNI kN/m GY -1.500 - - - -
121 UNI kN/m GY -3.880 - - - -
122 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.075 - - - -
123 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.135 - - - -
124 UNI kN/m GY -3.660 - - - -
UNI kN/m GY -1.500 - - - -
125 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.135 - - - -
128 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.880 - - - -
129 UNI kN/m GY -1.500 - - - -
130 UNI kN/m GY -5.075 - - - -
131 UNI kN/m GY -5.135 - - - -
132 UNI kN/m GY -3.660 - - - -
134 UNI kN/m GY -1.500 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 34 of 56
Job No Sheet No Rev
35
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 9 WL -Z SUCTION Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
135 UNI kN/m GY -1.500 - - - -
136 UNI kN/m GY -3.880 - - - -
137 UNI kN/m GY -5.075 - - - -
138 UNI kN/m GY -5.135 - - - -
139 UNI kN/m GY -3.660 - - - -
140 UNI kN/m GY -1.500 - - - -
141 UNI kN/m GY -1.500 - - - -
142 UNI kN/m GY -1.500 - - - -
145 UNI kN/m GY -1.500 - - - -
146 UNI kN/m GY -1.500 - - - -
151 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
153 UNI kN/m GY -1.070 - - - -
154 UNI kN/m GY -1.070 - - - -
157 UNI kN/m GY -1.500 - - - -
158 UNI kN/m GY -1.500 - - - -
159 UNI kN/m GY -1.500 - - - -
160 UNI kN/m GY -1.500 - - - -
161 UNI kN/m GY -1.500 - - - -
162 UNI kN/m GY -1.500 - - - -
163 UNI kN/m GY -1.500 - - - -
178 UNI kN/m GY -1.500 - - - -
179 UNI kN/m GY -1.500 - - - -
180 UNI kN/m GY -1.500 - - - -
181 UNI kN/m GY -1.500 - - - -
182 UNI kN/m GY -1.500 - - - -
183 UNI kN/m GY -1.500 - - - -
184 UNI kN/m GY -1.500 - - - -
199 UNI kN/m GY -1.500 - - - -
200 UNI kN/m GY -1.500 - - - -
201 UNI kN/m GY -1.500 - - - -
202 UNI kN/m GY -1.500 - - - -
203 UNI kN/m GY -1.500 - - - -
204 UNI kN/m GY -1.500 - - - -
205 UNI kN/m GY -1.500 - - - -
229 UNI kN/m GY -1.500 - - - -
230 UNI kN/m GY -1.500 - - - -
231 UNI kN/m GY -1.500 - - - -
232 UNI kN/m GY -1.500 - - - -
241 UNI kN/m GY -1.500 - - - -
242 UNI kN/m GY -1.500 - - - -
243 UNI kN/m GY -1.500 - - - -
244 UNI kN/m GY -1.500 - - - -
253 UNI kN/m GY -1.500 - - - -
254 UNI kN/m GY -1.500 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 35 of 56
Job No Sheet No Rev
36
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 9 WL -Z SUCTION Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
255 UNI kN/m GY -1.500 - - - -
256 UNI kN/m GY -1.500 - - - -
257 UNI kN/m GY -1.500 - - - -
258 UNI kN/m GY -1.500 - - - -
259 UNI kN/m GY -1.500 - - - -
260 UNI kN/m GY -1.500 - - - -
261 UNI kN/m GY -1.500 - - - -
262 UNI kN/m GY -1.500 - - - -
263 UNI kN/m GY -1.500 - - - -
264 UNI kN/m GY -1.500 - - - -
265 UNI kN/m GY -1.500 - - - -
266 UNI kN/m GY -1.500 - - - -
267 UNI kN/m GY -1.500 - - - -
268 UNI kN/m GY -1.500 - - - -
269 UNI kN/m GY -1.500 - - - -
270 UNI kN/m GY -1.500 - - - -
271 UNI kN/m GY -1.500 - - - -
272 UNI kN/m GY -1.500 - - - -
273 UNI kN/m GY -1.500 - - - -
325 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
326 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -1.470 - - - -
327 UNI kN/m GY -1.470 - - - -
UNI kN/m GY -1.500 - - - -
328 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -1.470 - - - -
329 UNI kN/m GY -0.625 - - - -
UNI kN/m GY -1.500 - - - -
330 UNI kN/m GY -0.625 - - - -
UNI kN/m GY -1.500 - - - -
349 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.880 - - - -
354 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
356 UNI kN/m GY -3.880 - - - -
UNI kN/m GY -1.500 - - - -
361 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -
370 UNI kN/m GY -5.075 - - - -
UNI kN/m GY -1.500 - - - -
372 UNI kN/m GY -3.880 - - - -
380 UNI kN/m GY -5.075 - - - -
389 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -5.075 - - - -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 36 of 56
Job No Sheet No Rev
37
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Beam Loads : 9 WL -Z SUCTION Cont...


Beam Type Direction Fa Da Fb Db Ecc.
(m) (m)
391 UNI kN/m GY -3.880 - - - -
399 UNI kN/m GY -5.075 - - - -
401 UNI kN/m GY -5.135 - - - -
404 UNI kN/m GY -3.660 - - - -
423 UNI kN/m GY -5.135 - - - -
UNI kN/m GY -1.500 - - - -
426 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -3.660 - - - -
447 UNI kN/m GY -1.070 - - - -
451 UNI kN/m GY -5.135 - - - -
453 UNI kN/m GY -3.660 - - - -
473 UNI kN/m GY -5.135 - - - -
UNI kN/m GY -1.500 - - - -
475 UNI kN/m GY -3.660 - - - -
UNI kN/m GY -1.500 - - - -
496 UNI kN/m GY -1.070 - - - -
498 UNI kN/m GY -1.070 - - - -
510 UNI kN/m GY -1.500 - - - -
UNI kN/m GY -0.625 - - - -

Temperature Loads : 10 TEMP +VE


Temperature Dif.
Beam Axial Cross
(C) (C)
114 32.000 -
115 32.000 -
116 32.000 -
117 32.000 -
118 32.000 -
119 32.000 -
120 32.000 -
121 32.000 -
122 32.000 -
123 32.000 -
124 32.000 -
125 32.000 -
126 32.000 -
128 32.000 -
129 32.000 -
130 32.000 -
131 32.000 -
132 32.000 -
134 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 37 of 56
Job No Sheet No Rev
38
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
135 32.000 -
136 32.000 -
137 32.000 -
138 32.000 -
139 32.000 -
140 32.000 -
141 32.000 -
142 32.000 -
145 32.000 -
146 32.000 -
147 32.000 -
148 32.000 -
151 32.000 -
153 32.000 -
154 32.000 -
157 32.000 -
158 32.000 -
159 32.000 -
160 32.000 -
161 32.000 -
162 32.000 -
163 32.000 -
164 32.000 -
165 32.000 -
166 32.000 -
167 32.000 -
168 32.000 -
169 32.000 -
170 32.000 -
171 32.000 -
172 32.000 -
173 32.000 -
174 32.000 -
175 32.000 -
176 32.000 -
177 32.000 -
178 32.000 -
179 32.000 -
180 32.000 -
181 32.000 -
182 32.000 -
183 32.000 -
184 32.000 -
185 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 38 of 56
Job No Sheet No Rev
39
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
186 32.000 -
187 32.000 -
188 32.000 -
189 32.000 -
190 32.000 -
191 32.000 -
192 32.000 -
193 32.000 -
194 32.000 -
195 32.000 -
196 32.000 -
197 32.000 -
198 32.000 -
199 32.000 -
200 32.000 -
201 32.000 -
202 32.000 -
203 32.000 -
204 32.000 -
205 32.000 -
206 32.000 -
207 32.000 -
208 32.000 -
209 32.000 -
210 32.000 -
211 32.000 -
212 32.000 -
213 32.000 -
214 32.000 -
215 32.000 -
216 32.000 -
217 32.000 -
218 32.000 -
219 32.000 -
220 32.000 -
221 32.000 -
222 32.000 -
223 32.000 -
225 32.000 -
227 32.000 -
229 32.000 -
230 32.000 -
231 32.000 -
232 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 39 of 56
Job No Sheet No Rev
40
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
233 32.000 -
234 32.000 -
235 32.000 -
236 32.000 -
237 32.000 -
238 32.000 -
239 32.000 -
240 32.000 -
241 32.000 -
242 32.000 -
243 32.000 -
244 32.000 -
245 32.000 -
246 32.000 -
247 32.000 -
248 32.000 -
249 32.000 -
250 32.000 -
251 32.000 -
252 32.000 -
253 32.000 -
254 32.000 -
255 32.000 -
256 32.000 -
257 32.000 -
258 32.000 -
259 32.000 -
260 32.000 -
261 32.000 -
262 32.000 -
263 32.000 -
264 32.000 -
265 32.000 -
266 32.000 -
267 32.000 -
268 32.000 -
269 32.000 -
270 32.000 -
271 32.000 -
272 32.000 -
273 32.000 -
274 32.000 -
275 32.000 -
276 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 40 of 56
Job No Sheet No Rev
41
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
277 32.000 -
278 32.000 -
279 32.000 -
280 32.000 -
281 32.000 -
282 32.000 -
283 32.000 -
284 32.000 -
285 32.000 -
286 32.000 -
287 32.000 -
288 32.000 -
289 32.000 -
290 32.000 -
291 32.000 -
292 32.000 -
293 32.000 -
294 32.000 -
295 32.000 -
296 32.000 -
297 32.000 -
298 32.000 -
299 32.000 -
300 32.000 -
301 32.000 -
302 32.000 -
303 32.000 -
304 32.000 -
305 32.000 -
306 32.000 -
307 32.000 -
308 32.000 -
309 32.000 -
310 32.000 -
311 32.000 -
312 32.000 -
313 32.000 -
314 32.000 -
315 32.000 -
316 32.000 -
317 32.000 -
318 32.000 -
319 32.000 -
320 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 41 of 56
Job No Sheet No Rev
42
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
321 32.000 -
322 32.000 -
323 32.000 -
324 32.000 -
325 32.000 -
326 32.000 -
327 32.000 -
328 32.000 -
329 32.000 -
330 32.000 -
331 32.000 -
332 32.000 -
333 32.000 -
334 32.000 -
335 32.000 -
336 32.000 -
337 32.000 -
338 32.000 -
339 32.000 -
340 32.000 -
341 32.000 -
342 32.000 -
343 32.000 -
344 32.000 -
345 32.000 -
346 32.000 -
347 32.000 -
348 32.000 -
349 32.000 -
350 32.000 -
351 32.000 -
352 32.000 -
353 32.000 -
354 32.000 -
355 32.000 -
356 32.000 -
357 32.000 -
358 32.000 -
359 32.000 -
360 32.000 -
361 32.000 -
362 32.000 -
363 32.000 -
364 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 42 of 56
Job No Sheet No Rev
43
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
365 32.000 -
366 32.000 -
367 32.000 -
368 32.000 -
369 32.000 -
370 32.000 -
371 32.000 -
372 32.000 -
373 32.000 -
374 32.000 -
375 32.000 -
376 32.000 -
377 32.000 -
378 32.000 -
379 32.000 -
380 32.000 -
381 32.000 -
382 32.000 -
383 32.000 -
384 32.000 -
385 32.000 -
386 32.000 -
387 32.000 -
388 32.000 -
389 32.000 -
390 32.000 -
391 32.000 -
392 32.000 -
393 32.000 -
394 32.000 -
395 32.000 -
396 32.000 -
397 32.000 -
398 32.000 -
399 32.000 -
400 32.000 -
401 32.000 -
402 32.000 -
403 32.000 -
404 32.000 -
405 32.000 -
406 32.000 -
407 32.000 -
408 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 43 of 56
Job No Sheet No Rev
44
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
409 32.000 -
410 32.000 -
411 32.000 -
412 32.000 -
413 32.000 -
414 32.000 -
415 32.000 -
416 32.000 -
417 32.000 -
418 32.000 -
419 32.000 -
420 32.000 -
421 32.000 -
422 32.000 -
423 32.000 -
424 32.000 -
425 32.000 -
426 32.000 -
427 32.000 -
428 32.000 -
429 32.000 -
430 32.000 -
431 32.000 -
432 32.000 -
433 32.000 -
434 32.000 -
435 32.000 -
436 32.000 -
437 32.000 -
438 32.000 -
439 32.000 -
440 32.000 -
441 32.000 -
442 32.000 -
443 32.000 -
444 32.000 -
445 32.000 -
446 32.000 -
447 32.000 -
448 32.000 -
449 32.000 -
450 32.000 -
451 32.000 -
452 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 44 of 56
Job No Sheet No Rev
45
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
453 32.000 -
454 32.000 -
455 32.000 -
456 32.000 -
457 32.000 -
458 32.000 -
459 32.000 -
460 32.000 -
461 32.000 -
462 32.000 -
463 32.000 -
464 32.000 -
465 32.000 -
466 32.000 -
467 32.000 -
468 32.000 -
469 32.000 -
470 32.000 -
471 32.000 -
472 32.000 -
473 32.000 -
474 32.000 -
475 32.000 -
476 32.000 -
477 32.000 -
478 32.000 -
479 32.000 -
480 32.000 -
481 32.000 -
482 32.000 -
483 32.000 -
484 32.000 -
485 32.000 -
486 32.000 -
487 32.000 -
488 32.000 -
489 32.000 -
490 32.000 -
491 32.000 -
492 32.000 -
493 32.000 -
494 32.000 -
495 32.000 -
496 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 45 of 56
Job No Sheet No Rev
46
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 10 TEMP +VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
497 32.000 -
498 32.000 -
499 32.000 -
500 32.000 -
501 32.000 -
502 32.000 -
503 32.000 -
504 32.000 -
505 32.000 -
506 32.000 -
507 32.000 -
508 32.000 -
509 32.000 -
510 32.000 -
511 32.000 -
512 32.000 -
513 32.000 -
514 32.000 -
515 32.000 -
516 32.000 -
517 32.000 -
518 32.000 -
519 32.000 -
520 32.000 -
521 32.000 -
522 32.000 -
523 32.000 -
524 32.000 -
525 32.000 -
526 32.000 -
527 32.000 -
528 32.000 -
529 32.000 -
530 32.000 -
531 32.000 -
532 32.000 -
533 32.000 -
534 32.000 -
535 32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 46 of 56
Job No Sheet No Rev
47
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE


Temperature Dif.
Beam Axial Cross
(C) (C)
114 -32.000 -
115 -32.000 -
116 -32.000 -
117 -32.000 -
118 -32.000 -
119 -32.000 -
120 -32.000 -
121 -32.000 -
122 -32.000 -
123 -32.000 -
124 -32.000 -
125 -32.000 -
126 -32.000 -
128 -32.000 -
129 -32.000 -
130 -32.000 -
131 -32.000 -
132 -32.000 -
134 -32.000 -
135 -32.000 -
136 -32.000 -
137 -32.000 -
138 -32.000 -
139 -32.000 -
140 -32.000 -
141 -32.000 -
142 -32.000 -
145 -32.000 -
146 -32.000 -
147 -32.000 -
148 -32.000 -
151 -32.000 -
153 -32.000 -
154 -32.000 -
157 -32.000 -
158 -32.000 -
159 -32.000 -
160 -32.000 -
161 -32.000 -
162 -32.000 -
163 -32.000 -
164 -32.000 -
165 -32.000 -
166 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 47 of 56
Job No Sheet No Rev
48
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
167 -32.000 -
168 -32.000 -
169 -32.000 -
170 -32.000 -
171 -32.000 -
172 -32.000 -
173 -32.000 -
174 -32.000 -
175 -32.000 -
176 -32.000 -
177 -32.000 -
178 -32.000 -
179 -32.000 -
180 -32.000 -
181 -32.000 -
182 -32.000 -
183 -32.000 -
184 -32.000 -
185 -32.000 -
186 -32.000 -
187 -32.000 -
188 -32.000 -
189 -32.000 -
190 -32.000 -
191 -32.000 -
192 -32.000 -
193 -32.000 -
194 -32.000 -
195 -32.000 -
196 -32.000 -
197 -32.000 -
198 -32.000 -
199 -32.000 -
200 -32.000 -
201 -32.000 -
202 -32.000 -
203 -32.000 -
204 -32.000 -
205 -32.000 -
206 -32.000 -
207 -32.000 -
208 -32.000 -
209 -32.000 -
210 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 48 of 56
Job No Sheet No Rev
49
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
211 -32.000 -
212 -32.000 -
213 -32.000 -
214 -32.000 -
215 -32.000 -
216 -32.000 -
217 -32.000 -
218 -32.000 -
219 -32.000 -
220 -32.000 -
221 -32.000 -
222 -32.000 -
223 -32.000 -
225 -32.000 -
227 -32.000 -
229 -32.000 -
230 -32.000 -
231 -32.000 -
232 -32.000 -
233 -32.000 -
234 -32.000 -
235 -32.000 -
236 -32.000 -
237 -32.000 -
238 -32.000 -
239 -32.000 -
240 -32.000 -
241 -32.000 -
242 -32.000 -
243 -32.000 -
244 -32.000 -
245 -32.000 -
246 -32.000 -
247 -32.000 -
248 -32.000 -
249 -32.000 -
250 -32.000 -
251 -32.000 -
252 -32.000 -
253 -32.000 -
254 -32.000 -
255 -32.000 -
256 -32.000 -
257 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 49 of 56
Job No Sheet No Rev
50
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
258 -32.000 -
259 -32.000 -
260 -32.000 -
261 -32.000 -
262 -32.000 -
263 -32.000 -
264 -32.000 -
265 -32.000 -
266 -32.000 -
267 -32.000 -
268 -32.000 -
269 -32.000 -
270 -32.000 -
271 -32.000 -
272 -32.000 -
273 -32.000 -
274 -32.000 -
275 -32.000 -
276 -32.000 -
277 -32.000 -
278 -32.000 -
279 -32.000 -
280 -32.000 -
281 -32.000 -
282 -32.000 -
283 -32.000 -
284 -32.000 -
285 -32.000 -
286 -32.000 -
287 -32.000 -
288 -32.000 -
289 -32.000 -
290 -32.000 -
291 -32.000 -
292 -32.000 -
293 -32.000 -
294 -32.000 -
295 -32.000 -
296 -32.000 -
297 -32.000 -
298 -32.000 -
299 -32.000 -
300 -32.000 -
301 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 50 of 56
Job No Sheet No Rev
51
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
302 -32.000 -
303 -32.000 -
304 -32.000 -
305 -32.000 -
306 -32.000 -
307 -32.000 -
308 -32.000 -
309 -32.000 -
310 -32.000 -
311 -32.000 -
312 -32.000 -
313 -32.000 -
314 -32.000 -
315 -32.000 -
316 -32.000 -
317 -32.000 -
318 -32.000 -
319 -32.000 -
320 -32.000 -
321 -32.000 -
322 -32.000 -
323 -32.000 -
324 -32.000 -
325 -32.000 -
326 -32.000 -
327 -32.000 -
328 -32.000 -
329 -32.000 -
330 -32.000 -
331 -32.000 -
332 -32.000 -
333 -32.000 -
334 -32.000 -
335 -32.000 -
336 -32.000 -
337 -32.000 -
338 -32.000 -
339 -32.000 -
340 -32.000 -
341 -32.000 -
342 -32.000 -
343 -32.000 -
344 -32.000 -
345 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 51 of 56
Job No Sheet No Rev
52
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
346 -32.000 -
347 -32.000 -
348 -32.000 -
349 -32.000 -
350 -32.000 -
351 -32.000 -
352 -32.000 -
353 -32.000 -
354 -32.000 -
355 -32.000 -
356 -32.000 -
357 -32.000 -
358 -32.000 -
359 -32.000 -
360 -32.000 -
361 -32.000 -
362 -32.000 -
363 -32.000 -
364 -32.000 -
365 -32.000 -
366 -32.000 -
367 -32.000 -
368 -32.000 -
369 -32.000 -
370 -32.000 -
371 -32.000 -
372 -32.000 -
373 -32.000 -
374 -32.000 -
375 -32.000 -
376 -32.000 -
377 -32.000 -
378 -32.000 -
379 -32.000 -
380 -32.000 -
381 -32.000 -
382 -32.000 -
383 -32.000 -
384 -32.000 -
385 -32.000 -
386 -32.000 -
387 -32.000 -
388 -32.000 -
389 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 52 of 56
Job No Sheet No Rev
53
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
390 -32.000 -
391 -32.000 -
392 -32.000 -
393 -32.000 -
394 -32.000 -
395 -32.000 -
396 -32.000 -
397 -32.000 -
398 -32.000 -
399 -32.000 -
400 -32.000 -
401 -32.000 -
402 -32.000 -
403 -32.000 -
404 -32.000 -
405 -32.000 -
406 -32.000 -
407 -32.000 -
408 -32.000 -
409 -32.000 -
410 -32.000 -
411 -32.000 -
412 -32.000 -
413 -32.000 -
414 -32.000 -
415 -32.000 -
416 -32.000 -
417 -32.000 -
418 -32.000 -
419 -32.000 -
420 -32.000 -
421 -32.000 -
422 -32.000 -
423 -32.000 -
424 -32.000 -
425 -32.000 -
426 -32.000 -
427 -32.000 -
428 -32.000 -
429 -32.000 -
430 -32.000 -
431 -32.000 -
432 -32.000 -
433 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 53 of 56
Job No Sheet No Rev
54
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
434 -32.000 -
435 -32.000 -
436 -32.000 -
437 -32.000 -
438 -32.000 -
439 -32.000 -
440 -32.000 -
441 -32.000 -
442 -32.000 -
443 -32.000 -
444 -32.000 -
445 -32.000 -
446 -32.000 -
447 -32.000 -
448 -32.000 -
449 -32.000 -
450 -32.000 -
451 -32.000 -
452 -32.000 -
453 -32.000 -
454 -32.000 -
455 -32.000 -
456 -32.000 -
457 -32.000 -
458 -32.000 -
459 -32.000 -
460 -32.000 -
461 -32.000 -
462 -32.000 -
463 -32.000 -
464 -32.000 -
465 -32.000 -
466 -32.000 -
467 -32.000 -
468 -32.000 -
469 -32.000 -
470 -32.000 -
471 -32.000 -
472 -32.000 -
473 -32.000 -
474 -32.000 -
475 -32.000 -
476 -32.000 -
477 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 54 of 56
Job No Sheet No Rev
55
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
478 -32.000 -
479 -32.000 -
480 -32.000 -
481 -32.000 -
482 -32.000 -
483 -32.000 -
484 -32.000 -
485 -32.000 -
486 -32.000 -
487 -32.000 -
488 -32.000 -
489 -32.000 -
490 -32.000 -
491 -32.000 -
492 -32.000 -
493 -32.000 -
494 -32.000 -
495 -32.000 -
496 -32.000 -
497 -32.000 -
498 -32.000 -
499 -32.000 -
500 -32.000 -
501 -32.000 -
502 -32.000 -
503 -32.000 -
504 -32.000 -
505 -32.000 -
506 -32.000 -
507 -32.000 -
508 -32.000 -
509 -32.000 -
510 -32.000 -
511 -32.000 -
512 -32.000 -
513 -32.000 -
514 -32.000 -
515 -32.000 -
516 -32.000 -
517 -32.000 -
518 -32.000 -
519 -32.000 -
520 -32.000 -
521 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 55 of 56
Job No Sheet No Rev
56
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Temperature Loads : 11 TEMP -VE Cont...


Temperature Dif.
Beam Axial Cross
(C) (C)
522 -32.000 -
523 -32.000 -
524 -32.000 -
525 -32.000 -
526 -32.000 -
527 -32.000 -
528 -32.000 -
529 -32.000 -
530 -32.000 -
531 -32.000 -
532 -32.000 -
533 -32.000 -
534 -32.000 -
535 -32.000 -

Print Time/Date: 29/06/2017 14:08 STAAD.Pro for Windows 20.07.04.12 Print Run 56 of 56
STAAD OUTPUT
Job No Sheet No Rev
1
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Node Displacement Summary


Node L/C X Y Z Resultant rX rY rZ
(mm) (mm) (mm) (mm) (rad) (rad) (rad)
Max X 300 218:1.2DL+1.2L 11.142 -33.269 13.264 37.509 0.004 -0.000 0.006
Min X 300 217:1.2DL+1.2L -9.795 -30.942 -11.096 34.300 0.003 0.000 0.006
Max Y 343 209:DL+1.4WL -1.615 83.327 -0.975 83.349 -0.009 -0.000 -0.009
Min Y 343 202:1.4DD+1.4 2.863 -85.632 1.689 85.696 0.004 0.000 0.010
Max Z 346 218:1.2DL+1.2L 4.422 -21.348 14.635 26.258 0.004 0.006 0.004
Min Z 346 217:1.2DL+1.2L -4.320 -20.988 -12.464 24.789 0.004 -0.005 0.004
Max rX 110 202:1.4DD+1.4 2.932 -34.639 0.062 34.763 0.010 0.000 0.008
Min rX 110 209:DL+1.4WL -1.654 39.856 -0.093 39.891 -0.011 -0.000 -0.007
Max rY 97 218:1.2DL+1.2L 0.000 0.000 0.000 0.000 0.000 0.011 0.003
Min rY 97 217:1.2DL+1.2L 0.000 0.000 0.000 0.000 -0.001 -0.011 0.003
Max rZ 342 202:1.4DD+1.4 2.679 -82.989 1.689 83.049 0.004 0.000 0.013
Min rZ 115 207:DL+1.4WL 4.513 63.041 2.131 63.239 -0.006 0.001 -0.011
Max Rst 343 202:1.4DD+1.4 2.863 -85.632 1.689 85.696 0.004 0.000 0.010

Beam End Force Summary


The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest tension
value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max Fx 403 318 217:1.2DL+1.2L 367.219 6.717 -0.467 -0.000 0.000 0.000
Min Fx 114 90 209:DL+1.4WL -423.010 -0.798 -54.557 0.840 -159.100 0.338
Max Fy 118 90 202:1.4DD+1.4 -0.370 183.232 1.120 -0.322 -1.810 555.659
Min Fy 118 90 209:DL+1.4WL 0.179 -270.177 -0.646 0.271 1.039 -658.926
Max Fz 404 323 217:1.2DL+1.2L -0.281 22.644 451.503 0.000 -67.725 3.324
Min Fz 404 323 218:1.2DL+1.2L -17.970 0.314 -449.936 0.000 67.490 -0.025
Max Mx 117 82 11:TEMP -VE -13.016 -10.565 7.103 4.362 -15.199 -32.279
Min Mx 117 82 215:1.2DL+0.5L 113.072 1.279 7.000 -9.214 -11.921 16.692
Max My 114 90 202:1.4DD+1.4 303.256 1.388 35.928 -1.471 125.755 -0.476
Min My 114 90 209:DL+1.4WL -423.010 -0.798 -54.557 0.840 -159.100 0.338
Max Mz 118 90 202:1.4DD+1.4 -0.370 183.232 1.120 -0.322 -1.810 555.659
Min Mz 118 90 209:DL+1.4WL 0.179 -270.177 -0.646 0.271 1.039 -658.926

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 1 of 11
Job No Sheet No Rev
2
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kNm) (kNm) (kNm)
Max FX 100 218:1.2DL+1.2L 449.936 0.654 -17.970 0.000 0.000 0.000
Min FX 100 217:1.2DL+1.2L -451.503 -21.676 -0.281 0.000 0.000 0.000
Max FY 78 202:1.4DD+1.4 -1.388 311.561 35.928 61.070 -1.471 6.743
Min FY 78 209:DL+1.4WL 0.798 -417.078 -30.315 -61.568 0.840 -3.812
Max FZ 80 206:1.4DL+1.4W -1.008 154.804 86.727 88.204 -1.012 5.231
Min FZ 97 202:1.4DD+1.4 -3.768 68.799 -36.656 0.000 0.000 0.000
Max MX 80 206:1.4DL+1.4W -1.008 154.804 86.727 88.204 -1.012 5.231
Min MX 78 209:DL+1.4WL 0.798 -417.078 -30.315 -61.568 0.840 -3.812
Max MY 82 11:TEMP -VE 10.565 -13.016 7.103 15.199 4.362 -32.279
Min MY 82 215:1.2DL+0.5L -1.279 113.072 7.000 11.921 -9.214 16.692
Max MZ 82 10:TEMP +VE -10.565 13.016 -7.103 -15.199 -4.362 32.279
Min MZ 82 218:1.2DL+1.2L 21.688 140.079 17.702 33.862 3.483 -50.728

Utilization Ratio
Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
114 PIP35512.5 PIP35512.5 0.507 1.000 0.507 BS-4.8.2.2 209 135.000 19.9E+3 19.9E+3 39.7E+3
115 PIP35512.5 PIP35512.5 0.300 1.000 0.300 BS-4.8.2.2 209 135.000 19.9E+3 19.9E+3 39.7E+3
116 PIP35512.5 PIP35512.5 0.299 1.000 0.299 BS-4.8.2.2 209 135.000 19.9E+3 19.9E+3 39.7E+3
117 PIP35512.5 PIP35512.5 0.311 1.000 0.311 ANNEX I.1 218 135.000 19.9E+3 19.9E+3 39.7E+3
118 UB533X210X UB533X210X 0.831 1.000 0.831 BS-4.3.6 209 155.000 76E+3 3.39E+3 178.377
119 UB533X210X UB533X210X 0.453 1.000 0.453 BS-4.3.6 209 129.000 61.5E+3 2.69E+3 100.953
120 UB533X210X UB533X210X 0.440 1.000 0.440 BS-4.3.6 202 129.000 61.5E+3 2.69E+3 100.953
121 UB533X210X UB533X210X 0.620 1.000 0.620 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
122 UB533X210X UB533X210X 0.380 1.000 0.380 BS-4.3.6 209 129.000 61.5E+3 2.69E+3 100.953
123 UB533X210X UB533X210X 0.391 1.000 0.391 BS-4.3.6 209 129.000 61.5E+3 2.69E+3 100.953
124 UB533X210X UB533X210X 0.372 1.000 0.372 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
125 UB533X210X UB533X210X 0.416 1.000 0.416 BS-4.8.2.2 209 129.000 61.5E+3 2.69E+3 100.953
126 UB533X210X UB533X210X 0.216 1.000 0.216 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
128 UB533X210X UB533X210X 0.357 1.000 0.357 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
129 UB533X210X UB533X210X 0.416 1.000 0.416 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
130 UB533X210X UB533X210X 0.308 1.000 0.308 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
131 UB533X210X UB533X210X 0.103 1.000 0.103 BS-4.8.2.2 217 129.000 61.5E+3 2.69E+3 100.953
132 UB533X210X UB533X210X 0.430 1.000 0.430 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
134 UB533X210X UB533X210X 0.116 1.000 0.116 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
135 UB533X210X UB533X210X 0.143 1.000 0.143 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
136 UB533X210X UB533X210X 0.051 1.000 0.051 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
137 UB533X210X UB533X210X 0.066 1.000 0.066 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
138 UB533X210X UB533X210X 0.044 1.000 0.044 ANNEX I.1 215 129.000 61.5E+3 2.69E+3 100.953
139 UB533X210X UB533X210X 0.055 1.000 0.055 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
140 UB533X210X UB533X210X 0.391 1.000 0.391 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
141 UB533X210X UB533X210X 0.414 1.000 0.414 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 2 of 11
Job No Sheet No Rev
3
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
142 UB533X210X UB533X210X 0.423 1.000 0.423 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
145 UB533X210X UB533X210X 0.051 1.000 0.051 ANNEX I.1 215 129.000 61.5E+3 2.69E+3 100.953
146 UB533X210X UB533X210X 0.090 1.000 0.090 BS-4.8.2.2 209 129.000 61.5E+3 2.69E+3 100.953
147 UB533X210X UB533X210X 0.187 1.000 0.187 BS-4.8.2.2 217 129.000 61.5E+3 2.69E+3 100.953
148 UB533X210X UB533X210X 0.165 1.000 0.165 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
151 UB533X210X UB533X210X 0.164 1.000 0.164 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
153 UB533X210X UB533X210X 0.102 1.000 0.102 BS-4.8.2.2 217 129.000 61.5E+3 2.69E+3 100.953
154 UB533X210X UB533X210X 0.126 1.000 0.126 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
157 UB533X210X UB533X210X 0.347 1.000 0.347 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
158 UB533X210X UB533X210X 0.280 1.000 0.280 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
159 UB533X210X UB533X210X 0.218 1.000 0.218 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
160 UB533X210X UB533X210X 0.165 1.000 0.165 BS-4.9 202 129.000 61.5E+3 2.69E+3 100.953
161 UB533X210X UB533X210X 0.120 1.000 0.120 BS-4.9 202 129.000 61.5E+3 2.69E+3 100.953
162 UB533X210X UB533X210X 0.081 1.000 0.081 BS-4.9 202 129.000 61.5E+3 2.69E+3 100.953
163 UB533X210X UB533X210X 0.060 1.000 0.060 ANNEX I.1 215 129.000 61.5E+3 2.69E+3 100.953
164 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
165 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
166 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
167 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
168 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
169 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
170 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
171 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
172 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
173 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
174 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
175 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
176 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
177 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
178 UB533X210X UB533X210X 0.029 1.000 0.029 ANNEX I.1 215 129.000 61.5E+3 2.69E+3 100.953
179 UB533X210X UB533X210X 0.026 1.000 0.026 BS-4.9 207 129.000 61.5E+3 2.69E+3 100.953
180 UB533X210X UB533X210X 0.024 1.000 0.024 BS-4.9 207 129.000 61.5E+3 2.69E+3 100.953
181 UB533X210X UB533X210X 0.023 1.000 0.023 BS-4.9 207 129.000 61.5E+3 2.69E+3 100.953
182 UB533X210X UB533X210X 0.028 1.000 0.028 ANNEX I.1 209 129.000 61.5E+3 2.69E+3 100.953
183 UB533X210X UB533X210X 0.054 1.000 0.054 ANNEX I.1 209 129.000 61.5E+3 2.69E+3 100.953
184 UB533X210X UB533X210X 0.089 1.000 0.089 ANNEX I.1 209 129.000 61.5E+3 2.69E+3 100.953
185 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
186 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
187 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
188 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
189 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
190 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
191 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
192 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
193 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 3 of 11
Job No Sheet No Rev
4
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
194 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
195 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
196 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
197 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
198 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
199 UB533X210X UB533X210X 0.057 1.000 0.057 BS-4.8.2.2 209 129.000 61.5E+3 2.69E+3 100.953
200 UB533X210X UB533X210X 0.042 1.000 0.042 BS-4.9 203 129.000 61.5E+3 2.69E+3 100.953
201 UB533X210X UB533X210X 0.051 1.000 0.051 BS-4.9 203 129.000 61.5E+3 2.69E+3 100.953
202 UB533X210X UB533X210X 0.060 1.000 0.060 BS-4.8.2.2 203 129.000 61.5E+3 2.69E+3 100.953
203 UB533X210X UB533X210X 0.065 1.000 0.065 BS-4.9 203 129.000 61.5E+3 2.69E+3 100.953
204 UB533X210X UB533X210X 0.066 1.000 0.066 BS-4.9 203 129.000 61.5E+3 2.69E+3 100.953
205 UB533X210X UB533X210X 0.100 1.000 0.100 ANNEX I.1 215 129.000 61.5E+3 2.69E+3 100.953
206 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
207 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
208 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
209 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
210 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
211 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
212 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
213 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
214 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
215 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
216 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
217 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
218 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
219 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
220 UB533X210X UB533X210X 0.051 1.000 0.051 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
221 UB533X210X UB533X210X 0.034 1.000 0.034 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
222 UB533X210X UB533X210X 0.107 1.000 0.107 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
223 UB254X102X UB254X102X 0.007 1.000 0.007 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
225 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
227 UB254X102X UB254X102X 0.006 1.000 0.006 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
229 UB533X210X UB533X210X 0.325 1.000 0.325 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
230 UB533X210X UB533X210X 0.242 1.000 0.242 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
231 UB533X210X UB533X210X 0.163 1.000 0.163 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
232 UB533X210X UB533X210X 0.089 1.000 0.089 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
233 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
234 UB254X102X UB254X102X 0.004 1.000 0.004 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
235 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
236 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 216 28.000 2.84E+3 119.000 4.145
237 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
238 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
239 UB254X102X UB254X102X 0.007 1.000 0.007 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
240 UB254X102X UB254X102X 0.007 1.000 0.007 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
241 UB533X210X UB533X210X 0.306 1.000 0.306 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 4 of 11
Job No Sheet No Rev
5
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
242 UB533X210X UB533X210X 0.228 1.000 0.228 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
243 UB533X210X UB533X210X 0.153 1.000 0.153 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
244 UB533X210X UB533X210X 0.100 1.000 0.100 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
245 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
246 UB254X102X UB254X102X 0.003 1.000 0.003 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
247 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 216 28.000 2.84E+3 119.000 4.145
248 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
249 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
250 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
251 UB254X102X UB254X102X 0.005 1.000 0.005 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
252 UB254X102X UB254X102X 0.005 1.000 0.005 BS-4.8.2.2 218 28.000 2.84E+3 119.000 4.145
253 UB533X210X UB533X210X 0.321 1.000 0.321 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
254 UB533X210X UB533X210X 0.248 1.000 0.248 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
255 UB533X210X UB533X210X 0.180 1.000 0.180 BS-4.8.2.2 202 129.000 61.5E+3 2.69E+3 100.953
256 UB533X210X UB533X210X 0.120 1.000 0.120 BS-4.9 202 129.000 61.5E+3 2.69E+3 100.953
257 UB533X210X UB533X210X 0.089 1.000 0.089 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
258 UB533X210X UB533X210X 0.113 1.000 0.113 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
259 UB533X210X UB533X210X 0.191 1.000 0.191 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
260 UB533X210X UB533X210X 0.081 1.000 0.081 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
261 UB533X210X UB533X210X 0.062 1.000 0.062 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
262 UB533X210X UB533X210X 0.061 1.000 0.061 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
263 UB533X210X UB533X210X 0.071 1.000 0.071 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
264 UB533X210X UB533X210X 0.081 1.000 0.081 BS-4.8.2.2 11 129.000 61.5E+3 2.69E+3 100.953
265 UB533X210X UB533X210X 0.093 1.000 0.093 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
266 UB533X210X UB533X210X 0.150 1.000 0.150 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
267 UB533X210X UB533X210X 0.123 1.000 0.123 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
268 UB533X210X UB533X210X 0.120 1.000 0.120 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
269 UB533X210X UB533X210X 0.108 1.000 0.108 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
270 UB533X210X UB533X210X 0.093 1.000 0.093 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
271 UB533X210X UB533X210X 0.075 1.000 0.075 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
272 UB533X210X UB533X210X 0.071 1.000 0.071 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
273 UB533X210X UB533X210X 0.106 1.000 0.106 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
274 UB254X102X UB254X102X 0.004 1.000 0.004 BS-4.8.2.2 218 28.000 2.84E+3 119.000 4.145
275 UB254X102X UB254X102X 0.004 1.000 0.004 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
276 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
277 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 218 28.000 2.84E+3 119.000 4.145
278 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
279 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
280 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
281 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
282 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
283 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
284 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 218 28.000 2.84E+3 119.000 4.145
285 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
286 UB254X102X UB254X102X 0.003 1.000 0.003 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 5 of 11
Job No Sheet No Rev
6
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
287 UB254X102X UB254X102X 0.003 1.000 0.003 BS-4.8.2.2 218 28.000 2.84E+3 119.000 4.145
288 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 218 28.000 2.84E+3 119.000 4.145
289 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
290 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
291 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 218 28.000 2.84E+3 119.000 4.145
292 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
293 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
294 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
295 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
296 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
297 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
298 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
299 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
300 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 215 28.000 2.84E+3 119.000 4.145
301 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 215 28.000 2.84E+3 119.000 4.145
302 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
303 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
304 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
305 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
306 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
307 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
308 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
309 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
310 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
311 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
312 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
313 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
314 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
315 UB254X102X UB254X102X 0.002 1.000 0.002 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
316 UB533X210X UB533X210X 0.069 1.000 0.069 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
317 UB533X210X UB533X210X 0.044 1.000 0.044 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
318 UB533X210X UB533X210X 0.217 1.000 0.217 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
319 UB254X102X UB254X102X 0.083 1.000 0.083 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
320 UB254X102X UB254X102X 0.076 1.000 0.076 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
321 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.2.2 206 28.000 2.84E+3 119.000 4.145
322 UB254X102X UB254X102X 0.008 1.000 0.008 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
323 UB254X102X UB254X102X 0.070 1.000 0.070 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
324 UB254X102X UB254X102X 0.032 1.000 0.032 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
325 UB533X210X UB533X210X 0.108 1.000 0.108 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
326 UB533X210X UB533X210X 0.118 1.000 0.118 BS-4.8.2.2 207 129.000 61.5E+3 2.69E+3 100.953
327 UB533X210X UB533X210X 0.121 1.000 0.121 BS-4.8.2.2 207 129.000 61.5E+3 2.69E+3 100.953
328 UB533X210X UB533X210X 0.119 1.000 0.119 BS-4.8.2.2 207 129.000 61.5E+3 2.69E+3 100.953
329 UB533X210X UB533X210X 0.101 1.000 0.101 BS-4.8.2.2 207 129.000 61.5E+3 2.69E+3 100.953
330 UB533X210X UB533X210X 0.090 1.000 0.090 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
331 UB254X102X UB254X102X 0.011 1.000 0.011 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 6 of 11
Job No Sheet No Rev
7
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
332 UB254X102X UB254X102X 0.006 1.000 0.006 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
333 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
334 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
335 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
336 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.2.3-(Y) 201 28.000 2.84E+3 119.000 4.145
337 UB254X102X UB254X102X 0.000 1.000 0.000 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
338 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
339 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
340 UB254X102X UB254X102X 0.004 1.000 0.004 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
341 UB254X102X UB254X102X 0.008 1.000 0.008 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
342 UB254X102X UB254X102X 0.016 1.000 0.016 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
343 UB533X210X UB533X210X 0.152 1.000 0.152 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
344 UB533X210X UB533X210X 0.062 1.000 0.062 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
345 UB533X210X UB533X210X 0.092 1.000 0.092 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
346 UB254X102X UB254X102X 0.063 1.000 0.063 BS-4.7 (C) 218 28.000 2.84E+3 119.000 4.145
347 UB254X102X UB254X102X 0.004 1.000 0.004 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
348 UB254X102X UB254X102X 0.051 1.000 0.051 BS-4.7 (C) 217 28.000 2.84E+3 119.000 4.145
349 UB533X210X UB533X210X 0.774 1.000 0.774 BS-4.3.6 209 155.000 76E+3 3.39E+3 178.377
350 UB356X171X UB356X171X 0.050 1.000 0.050 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
351 UB356X171X UB356X171X 0.058 1.000 0.058 BS-4.9 217 64.900 14.1E+3 968.000 23.811
352 UB356X171X UB356X171X 0.046 1.000 0.046 BS-4.9 202 64.900 14.1E+3 968.000 23.811
353 UB356X171X UB356X171X 0.046 1.000 0.046 BS-4.9 202 64.900 14.1E+3 968.000 23.811
354 UB533X210X UB533X210X 0.165 1.000 0.165 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
355 UB356X171X UB356X171X 0.055 1.000 0.055 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
356 UB533X210X UB533X210X 0.229 1.000 0.229 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
357 UB356X171X UB356X171X 0.072 1.000 0.072 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
358 UB356X171X UB356X171X 0.080 1.000 0.080 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
359 UB356X171X UB356X171X 0.051 1.000 0.051 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
360 UB356X171X UB356X171X 0.046 1.000 0.046 ANNEX I.1 202 64.900 14.1E+3 968.000 23.811
361 UB533X210X UB533X210X 0.076 1.000 0.076 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
362 UB356X171X UB356X171X 0.041 1.000 0.041 ANNEX I.1 202 64.900 14.1E+3 968.000 23.811
363 UB356X127X UB356X127X 0.119 1.000 0.119 BS-4.8.2.2 217 49.800 10.2E+3 358.000 15.097
364 UB356X127X UB356X127X 0.132 1.000 0.132 ANNEX I.1 218 49.800 10.2E+3 358.000 15.097
365 UB356X127X UB356X127X 0.136 1.000 0.136 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
366 UB356X127X UB356X127X 0.144 1.000 0.144 BS-4.9 202 49.800 10.2E+3 358.000 15.097
367 UB356X127X UB356X127X 0.143 1.000 0.143 BS-4.9 202 49.800 10.2E+3 358.000 15.097
368 UB356X127X UB356X127X 0.136 1.000 0.136 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
369 UB356X127X UB356X127X 0.114 1.000 0.114 BS-4.9 202 49.800 10.2E+3 358.000 15.097
370 UB533X210X UB533X210X 0.149 1.000 0.149 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
371 UB356X127X UB356X127X 0.102 1.000 0.102 BS-4.8.2.2 217 49.800 10.2E+3 358.000 15.097
372 UB533X210X UB533X210X 0.639 1.000 0.639 BS-4.9 218 129.000 61.5E+3 2.69E+3 100.953
373 UB356X127X UB356X127X 0.348 1.000 0.348 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
374 UB356X127X UB356X127X 0.348 1.000 0.348 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
375 UB356X127X UB356X127X 0.337 1.000 0.337 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
376 UB356X127X UB356X127X 0.337 1.000 0.337 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 7 of 11
Job No Sheet No Rev
8
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
377 UB356X127X UB356X127X 0.325 1.000 0.325 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
378 UB356X127X UB356X127X 0.323 1.000 0.323 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
379 UB356X127X UB356X127X 0.330 1.000 0.330 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
380 UB533X210X UB533X210X 0.107 1.000 0.107 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
381 UB356X127X UB356X127X 0.330 1.000 0.330 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
382 UB356X127X UB356X127X 0.069 1.000 0.069 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
383 UB356X127X UB356X127X 0.112 1.000 0.112 BS-4.9 202 49.800 10.2E+3 358.000 15.097
384 UB356X127X UB356X127X 0.135 1.000 0.135 BS-4.9 202 49.800 10.2E+3 358.000 15.097
385 UB356X127X UB356X127X 0.143 1.000 0.143 BS-4.9 202 49.800 10.2E+3 358.000 15.097
386 UB356X127X UB356X127X 0.143 1.000 0.143 BS-4.9 202 49.800 10.2E+3 358.000 15.097
387 UB356X127X UB356X127X 0.135 1.000 0.135 BS-4.9 202 49.800 10.2E+3 358.000 15.097
388 UB356X127X UB356X127X 0.112 1.000 0.112 BS-4.9 202 49.800 10.2E+3 358.000 15.097
389 UB533X210X UB533X210X 0.067 1.000 0.067 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
390 UB356X127X UB356X127X 0.068 1.000 0.068 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
391 UB533X210X UB533X210X 0.009 1.000 0.009 BS-4.2.3-(Y) 209 129.000 61.5E+3 2.69E+3 100.953
392 UB356X127X UB356X127X 0.068 1.000 0.068 BS-4.8.2.2 217 49.800 10.2E+3 358.000 15.097
393 UB356X127X UB356X127X 0.112 1.000 0.112 ANNEX I.1 202 49.800 10.2E+3 358.000 15.097
394 UB356X127X UB356X127X 0.135 1.000 0.135 ANNEX I.1 202 49.800 10.2E+3 358.000 15.097
395 UB356X127X UB356X127X 0.143 1.000 0.143 ANNEX I.1 202 49.800 10.2E+3 358.000 15.097
396 UB356X127X UB356X127X 0.143 1.000 0.143 ANNEX I.1 202 49.800 10.2E+3 358.000 15.097
397 UB356X127X UB356X127X 0.135 1.000 0.135 ANNEX I.1 202 49.800 10.2E+3 358.000 15.097
398 UB356X127X UB356X127X 0.112 1.000 0.112 ANNEX I.1 202 49.800 10.2E+3 358.000 15.097
399 UB533X210X UB533X210X 0.009 1.000 0.009 BS-4.2.3-(Y) 209 129.000 61.5E+3 2.69E+3 100.953
400 UB356X127X UB356X127X 0.068 1.000 0.068 ANNEX I.1 202 49.800 10.2E+3 358.000 15.097
401 UB533X210X UB533X210X 0.059 1.000 0.059 BS-4.2.3-(Y) 207 129.000 61.5E+3 2.69E+3 100.953
402 UB356X127X UB356X127X 0.300 1.000 0.300 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
403 UB356X127X UB356X127X 0.331 1.000 0.331 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
404 UB533X210X UB533X210X 0.645 1.000 0.645 BS-4.8.2.2 217 129.000 61.5E+3 2.69E+3 100.953
405 UB356X171X UB356X171X 0.800 1.000 0.800 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
406 UB356X127X UB356X127X 0.311 1.000 0.311 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
407 UB356X127X UB356X127X 0.322 1.000 0.322 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
408 UB356X127X UB356X127X 0.333 1.000 0.333 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
409 UB356X127X UB356X127X 0.335 1.000 0.335 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
410 UB356X127X UB356X127X 0.335 1.000 0.335 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
411 UB356X127X UB356X127X 0.325 1.000 0.325 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
412 UB356X127X UB356X127X 0.317 1.000 0.317 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
413 UB356X127X UB356X127X 0.341 1.000 0.341 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
414 UB356X127X UB356X127X 0.352 1.000 0.352 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
415 UB356X127X UB356X127X 0.353 1.000 0.353 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
416 UB356X127X UB356X127X 0.352 1.000 0.352 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
417 UB356X127X UB356X127X 0.342 1.000 0.342 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
418 UB356X127X UB356X127X 0.325 1.000 0.325 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
419 UB356X127X UB356X127X 0.310 1.000 0.310 BS-4.8.2.2 218 49.800 10.2E+3 358.000 15.097
420 UB356X171X UB356X171X 0.175 1.000 0.175 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
421 UB356X171X UB356X171X 0.097 1.000 0.097 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 8 of 11
Job No Sheet No Rev
9
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
422 UB356X171X UB356X171X 0.409 1.000 0.409 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
423 UB533X210X UB533X210X 0.090 1.000 0.090 ANNEX I.1 207 129.000 61.5E+3 2.69E+3 100.953
424 UB356X127X UB356X127X 0.086 1.000 0.086 BS-4.8.2.2 217 49.800 10.2E+3 358.000 15.097
425 UB356X127X UB356X127X 0.085 1.000 0.085 BS-4.8.2.2 217 49.800 10.2E+3 358.000 15.097
426 UB533X210X UB533X210X 0.282 1.000 0.282 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
427 UB254X102X UB254X102X 0.083 1.000 0.083 BS-4.7 (C) 218 28.000 2.84E+3 119.000 4.145
428 UB356X171X UB356X171X 0.146 1.000 0.146 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
429 UB356X127X UB356X127X 0.117 1.000 0.117 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
430 UB356X127X UB356X127X 0.142 1.000 0.142 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
431 UB356X127X UB356X127X 0.149 1.000 0.149 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
432 UB356X127X UB356X127X 0.149 1.000 0.149 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
433 UB356X127X UB356X127X 0.142 1.000 0.142 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
434 UB356X127X UB356X127X 0.117 1.000 0.117 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
435 UB356X127X UB356X127X 0.106 1.000 0.106 BS-4.8.2.2 217 49.800 10.2E+3 358.000 15.097
436 UB356X127X UB356X127X 0.114 1.000 0.114 BS-4.9 202 49.800 10.2E+3 358.000 15.097
437 UB356X127X UB356X127X 0.139 1.000 0.139 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
438 UB356X127X UB356X127X 0.146 1.000 0.146 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
439 UB356X127X UB356X127X 0.146 1.000 0.146 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
440 UB356X127X UB356X127X 0.139 1.000 0.139 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
441 UB356X127X UB356X127X 0.114 1.000 0.114 BS-4.9 202 49.800 10.2E+3 358.000 15.097
442 UB356X127X UB356X127X 0.074 1.000 0.074 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
443 UB254X102X UB254X102X 0.003 1.000 0.003 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
444 UB356X171X UB356X171X 0.064 1.000 0.064 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
445 UB254X102X UB254X102X 0.082 1.000 0.082 BS-4.7 (C) 217 28.000 2.84E+3 119.000 4.145
446 UB356X171X UB356X171X 0.039 1.000 0.039 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
447 UB533X210X UB533X210X 0.192 1.000 0.192 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
448 UB356X171X UB356X171X 0.084 1.000 0.084 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
449 UB533X210X UB533X210X 0.376 1.000 0.376 BS-4.8.2.2 217 129.000 61.5E+3 2.69E+3 100.953
450 UB356X127X UB356X127X 0.068 1.000 0.068 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
451 UB533X210X UB533X210X 0.009 1.000 0.009 BS-4.2.3-(Y) 209 129.000 61.5E+3 2.69E+3 100.953
452 UB356X127X UB356X127X 0.072 1.000 0.072 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
453 UB533X210X UB533X210X 0.003 1.000 0.003 BS-4.2.3-(Y) 209 129.000 61.5E+3 2.69E+3 100.953
454 UB356X171X UB356X171X 0.109 1.000 0.109 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
455 UB356X127X UB356X127X 0.112 1.000 0.112 BS-4.9 202 49.800 10.2E+3 358.000 15.097
456 UB356X127X UB356X127X 0.136 1.000 0.136 BS-4.9 202 49.800 10.2E+3 358.000 15.097
457 UB356X127X UB356X127X 0.144 1.000 0.144 BS-4.9 202 49.800 10.2E+3 358.000 15.097
458 UB356X127X UB356X127X 0.144 1.000 0.144 BS-4.9 202 49.800 10.2E+3 358.000 15.097
459 UB356X127X UB356X127X 0.136 1.000 0.136 BS-4.9 202 49.800 10.2E+3 358.000 15.097
460 UB356X127X UB356X127X 0.112 1.000 0.112 BS-4.9 202 49.800 10.2E+3 358.000 15.097
461 UB356X127X UB356X127X 0.068 1.000 0.068 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
462 UB356X127X UB356X127X 0.116 1.000 0.116 BS-4.9 202 49.800 10.2E+3 358.000 15.097
463 UB356X127X UB356X127X 0.141 1.000 0.141 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
464 UB356X127X UB356X127X 0.149 1.000 0.149 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
465 UB356X127X UB356X127X 0.149 1.000 0.149 BS-4.9 202 49.800 10.2E+3 358.000 15.097
466 UB356X127X UB356X127X 0.142 1.000 0.142 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 9 of 11
Job No Sheet No Rev
10
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
467 UB356X127X UB356X127X 0.117 1.000 0.117 BS-4.9 202 49.800 10.2E+3 358.000 15.097
468 UB356X127X UB356X127X 0.072 1.000 0.072 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
469 UB356X171X UB356X171X 0.017 1.000 0.017 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
470 UB356X171X UB356X171X 0.017 1.000 0.017 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
471 UB356X171X UB356X171X 0.089 1.000 0.089 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
472 UB356X127X UB356X127X 0.069 1.000 0.069 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
473 UB533X210X UB533X210X 0.103 1.000 0.103 BS-4.2.3-(Y) 209 129.000 61.5E+3 2.69E+3 100.953
474 UB356X127X UB356X127X 0.071 1.000 0.071 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
475 UB533X210X UB533X210X 0.089 1.000 0.089 ANNEX I.1 217 129.000 61.5E+3 2.69E+3 100.953
476 UB254X102X UB254X102X 0.028 1.000 0.028 BS-4.8.2.2 217 28.000 2.84E+3 119.000 4.145
477 UB356X171X UB356X171X 0.115 1.000 0.115 BS-4.9 217 64.900 14.1E+3 968.000 23.811
478 UB356X127X UB356X127X 0.112 1.000 0.112 BS-4.9 202 49.800 10.2E+3 358.000 15.097
479 UB356X127X UB356X127X 0.136 1.000 0.136 BS-4.9 202 49.800 10.2E+3 358.000 15.097
480 UB356X127X UB356X127X 0.144 1.000 0.144 BS-4.9 202 49.800 10.2E+3 358.000 15.097
481 UB356X127X UB356X127X 0.144 1.000 0.144 BS-4.9 202 49.800 10.2E+3 358.000 15.097
482 UB356X127X UB356X127X 0.136 1.000 0.136 BS-4.9 202 49.800 10.2E+3 358.000 15.097
483 UB356X127X UB356X127X 0.112 1.000 0.112 BS-4.9 202 49.800 10.2E+3 358.000 15.097
484 UB356X127X UB356X127X 0.069 1.000 0.069 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
485 UB356X127X UB356X127X 0.116 1.000 0.116 BS-4.9 202 49.800 10.2E+3 358.000 15.097
486 UB356X127X UB356X127X 0.141 1.000 0.141 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
487 UB356X127X UB356X127X 0.149 1.000 0.149 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
488 UB356X127X UB356X127X 0.149 1.000 0.149 BS-4.9 202 49.800 10.2E+3 358.000 15.097
489 UB356X127X UB356X127X 0.141 1.000 0.141 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
490 UB356X127X UB356X127X 0.117 1.000 0.117 BS-4.9 202 49.800 10.2E+3 358.000 15.097
491 UB356X127X UB356X127X 0.072 1.000 0.072 BS-4.8.2.2 202 49.800 10.2E+3 358.000 15.097
492 UB254X102X UB254X102X 0.001 1.000 0.001 BS-4.8.3.3.2 218 28.000 2.84E+3 119.000 4.145
493 UB356X171X UB356X171X 0.016 1.000 0.016 ANNEX I.1 215 64.900 14.1E+3 968.000 23.811
494 UB254X102X UB254X102X 0.022 1.000 0.022 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
495 UB356X171X UB356X171X 0.021 1.000 0.021 BS-4.9 217 64.900 14.1E+3 968.000 23.811
496 UB533X210X UB533X210X 0.059 1.000 0.059 BS-4.8.2.2 217 129.000 61.5E+3 2.69E+3 100.953
497 UB356X171X UB356X171X 0.136 1.000 0.136 BS-4.9 217 64.900 14.1E+3 968.000 23.811
498 UB533X210X UB533X210X 0.045 1.000 0.045 BS-4.8.2.2 217 129.000 61.5E+3 2.69E+3 100.953
499 UB356X171X UB356X171X 0.103 1.000 0.103 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
500 UB356X171X UB356X171X 0.103 1.000 0.103 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
501 UB356X171X UB356X171X 0.084 1.000 0.084 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
502 UB356X171X UB356X171X 0.096 1.000 0.096 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
503 UB356X171X UB356X171X 0.096 1.000 0.096 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
504 UB254X102X UB254X102X 0.045 1.000 0.045 BS-4.8.3.3.2 217 28.000 2.84E+3 119.000 4.145
505 UB356X171X UB356X171X 0.094 1.000 0.094 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
506 UB356X171X UB356X171X 0.094 1.000 0.094 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
507 UB356X171X UB356X171X 0.070 1.000 0.070 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
508 UB356X171X UB356X171X 0.061 1.000 0.061 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
509 UB356X171X UB356X171X 0.047 1.000 0.047 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
510 UB533X210X UB533X210X 0.006 1.000 0.006 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
511 UB533X210X UB533X210X 0.261 1.000 0.261 BS-4.9 218 129.000 61.5E+3 2.69E+3 100.953

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 10 of 11
Job No Sheet No Rev
11
Part
Software licensed to
Job Title Ref

By Date11-Jun-17 Chd

Client File CANOPY-02rev-02-01.std Date/Time 29-Jun-2017 13:49

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
512 UB356X171X UB356X171X 0.271 1.000 0.271 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
513 UB356X171X UB356X171X 0.019 1.000 0.019 BS-4.8.3.3.2 218 64.900 14.1E+3 968.000 23.811
514 UB533X210X UB533X210X 0.252 1.000 0.252 BS-4.8.2.2 218 129.000 61.5E+3 2.69E+3 100.953
515 UB356X171X UB356X171X 0.465 1.000 0.465 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
516 UB356X171X UB356X171X 0.440 1.000 0.440 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
517 UB356X171X UB356X171X 0.110 1.000 0.110 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
518 UB356X171X UB356X171X 0.106 1.000 0.106 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
519 UB356X171X UB356X171X 0.096 1.000 0.096 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
520 UB356X171X UB356X171X 0.087 1.000 0.087 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
521 UB356X171X UB356X171X 0.087 1.000 0.087 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
522 UB356X171X UB356X171X 0.132 1.000 0.132 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
523 UB356X171X UB356X171X 0.110 1.000 0.110 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
524 UB356X171X UB356X171X 0.276 1.000 0.276 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
525 UB533X210X UB533X210X 0.395 1.000 0.395 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
526 UB533X210X UB533X210X 0.154 1.000 0.154 ANNEX I.1 218 129.000 61.5E+3 2.69E+3 100.953
527 UB356X171X UB356X171X 0.095 1.000 0.095 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
528 UB356X171X UB356X171X 0.077 1.000 0.077 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
529 UB356X171X UB356X171X 0.067 1.000 0.067 ANNEX I.1 202 64.900 14.1E+3 968.000 23.811
530 UB356X171X UB356X171X 0.065 1.000 0.065 ANNEX I.1 202 64.900 14.1E+3 968.000 23.811
531 UB356X171X UB356X171X 0.073 1.000 0.073 ANNEX I.1 218 64.900 14.1E+3 968.000 23.811
532 UB356X171X UB356X171X 0.041 1.000 0.041 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
533 UB356X171X UB356X171X 0.057 1.000 0.057 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811
534 UB356X171X UB356X171X 0.056 1.000 0.056 BS-4.8.2.2 218 64.900 14.1E+3 968.000 23.811
535 UB356X171X UB356X171X 0.080 1.000 0.080 BS-4.8.2.2 217 64.900 14.1E+3 968.000 23.811

Print Time/Date: 29/06/2017 14:10 STAAD.Pro for Windows 20.07.04.12 Print Run 11 of 11
STRUCTURAL CALCULATION Reference : ARTESIA MIDRISE BUILDING G+28
ON PLOT 676-5408
Project No: 783 Prepared by : SAB/ASV Date : 29-06-2017
Item: Structural Analysis for canopy structure at Checked by : ASV Rev : 0
tower a - 27 th level

REFERENCES
TABLE 16-N 1997 UNIFORM BUILDING CODE
TABLE 16-N

TABLE 16-NSTRUCTURAL SYSTEMS1


HEIGHT LIMIT FOR
SEISMIC ZONES 3
AND 4 (feet)

BASIC STRUCTURAL SYSTEM2 LATERAL-FORCE-RESISTING SYSTEM DESCRIPTION R Wo 304.8 for mm


1. Bearing wall system 1. Light-framed walls with shear panels
a. Wood structural panel walls for structures three stories or less 5.5 2.8 65
b. All other light-framed walls 4.5 2.8 65
2. Shear walls
a. Concrete 4.5 2.8 160
b. Masonry 4.5 2.8 160
3. Light steel-framed bearing walls with tension-only bracing 2.8 2.2 65
4. Braced frames where bracing carries gravity load
a. Steel 4.4 2.2 160
b. Concrete3 2.8 2.2
c. Heavy timber 2.8 2.2 65
2. Building frame system 1. Steel eccentrically braced frame (EBF) 7.0 2.8 240
2. Light-framed walls with shear panels
a. Wood structural panel walls for structures three stories or less 6.5 2.8 65
b. All other light-framed walls 5.0 2.8 65
3. Shear walls
a. Concrete 5.5 2.8 240
b. Masonry 5.5 2.8 160
4. Ordinary braced frames
a. Steel 5.6 2.2 160
b. Concrete3 5.6 2.2
c. Heavy timber 5.6 2.2 65
5. Special concentrically braced frames
a. Steel 6.4 2.2 240
3. Moment-resisting frame 1. Special moment-resisting frame (SMRF)
system a. Steel 8.5 2.8 N.L.
b. Concrete4 8.5 2.8 N.L.
2. Masonry moment-resisting wall frame (MMRWF) 6.5 2.8 160
3. Concrete intermediate moment-resisting frame (IMRF)5 5.5 2.8
4. Ordinary moment-resisting frame (OMRF)
a. Steel6 4.5 2.8 160
b. Concrete7 3.5 2.8
5. Special truss moment frames of steel (STMF) 6.5 2.8 240
4. Dual systems 1. Shear walls
a. Concrete with SMRF 8.5 2.8 N.L.
b. Concrete with steel OMRF 4.2 2.8 160
c. Concrete with concrete IMRF5 6.5 2.8 160
d. Masonry with SMRF 5.5 2.8 160
e. Masonry with steel OMRF 4.2 2.8 160
f. Masonry with concrete IMRF3 4.2 2.8
g. Masonry with masonry MMRWF 6.0 2.8 160
2. Steel EBF
a. With steel SMRF 8.5 2.8 N.L.
b. With steel OMRF 4.2 2.8 160
3. Ordinary braced frames
a. Steel with steel SMRF 6.5 2.8 N.L.
b. Steel with steel OMRF 4.2 2.8 160
c. Concrete with concrete SMRF3 6.5 2.8
d. Concrete with concrete IMRF3 4.2 2.8
4. Special concentrically braced frames
a. Steel with steel SMRF 7.5 2.8 N.L.
b. Steel with steel OMRF 4.2 2.8 160
5. Cantilevered column building 1. Cantilevered column elements 2.2 2.0 357
systems
6. Shear wall-frame interaction 1. Concrete8 5.5 2.8 160
systems
7. Undefined systems See Sections 1629.6.7 and 1629.9.2
N.L.no limit
1See Section 1630.4 for combination of structural systems.
2Basic structural systems are defined in Section 1629.6.
3Prohibited in Seismic Zones 3 and 4.
4Includes precast concrete conforming to Section 1921.2.7.
5Prohibited in Seismic Zones 3 and 4, except as permitted in Section 1634.2.
6Ordinary moment-resisting frames in Seismic Zone 1 meeting the requirements of Section 2211.6 may use a R value of 8.
7 Total height of the building including cantilevered columns.
8Prohibited in Seismic Zones 2A, 2B, 3 and 4. See Section 1633.2.7.

232
335 of 341
1997 UNIFORM BUILDING CODE TABLE 16-R
TABLE 16-U

TABLE 16-RSEISMIC COEFFICIENT Cv


SEISMIC ZONE FACTOR, Z
SOIL PROFILE TYPE Z = 0.075 Z = 0.15 Z = 0.2 Z = 0.3 Z = 0.4
SA 0.06 0.12 0.16 0.24 0.32Nv
SB 0.08 0.15 0.20 0.30 0.40Nv
SC 0.13 0.25 0.32 0.45 0.56Nv
SD 0.18 0.32 0.40 0.54 0.64Nv
SE 0.26 0.50 0.64 0.84 0.96Nv
SF See Footnote 1
1Site-specific geotechnical investigation and dynamic site response analysis shall be performed to determine seismic coefficients for Soil Profile Type S .
F

TABLE 16-SNEAR-SOURCE FACTOR Na 1


CLOSEST DISTANCE TO KNOWN SEISMIC SOURCE2,3
SEISMIC SOURCE TYPE v 2 km 5 km w 10 km
A 1.5 1.2 1.0
B 1.3 1.0 1.0
C 1.0 1.0 1.0
1The Near-Source Factor may be based on the linear interpolation of values for distances other than those shown in the table.
2The location and type of seismic sources to be used for design shall be established based on approved geotechnical data (e.g., most recent mapping of active faults by
the United States Geological Survey or the California Division of Mines and Geology).
3The closest distance to seismic source shall be taken as the minimum distance between the site and the area described by the vertical projection of the source on the
surface (i.e., surface projection of fault plane). The surface projection need not include portions of the source at depths of 10 km or greater. The largest value of the
Near-Source Factor considering all sources shall be used for design.

TABLE 16-TNEAR-SOURCE FACTOR Nv 1


CLOSEST DISTANCE TO KNOWN SEISMIC SOURCE2,3
SEISMIC SOURCE TYPE v 2 km 5 km 10 km w 15 km
A 2.0 1.6 1.2 1.0
B 1.6 1.2 1.0 1.0
C 1.0 1.0 1.0 1.0
1The Near-Source Factor may be based on the linear interpolation of values for distances other than those shown in the table.
2The location and type of seismic sources to be used for design shall be established based on approved geotechnical data (e.g., most recent mapping of active faults by
the United States Geological Survey or the California Division of Mines and Geology).
3The closest distance to seismic source shall be taken as the minimum distance between the site and the area described by the vertical projection of the source on the
surface (i.e., surface projection of fault plane). The surface projection need not include portions of the source at depths of 10 km or greater. The largest value of the
Near-Source Factor considering all sources shall be used for design.

TABLE 16-USEISMIC SOURCE TYPE1


SEISMIC SOURCE DEFINITION2
SEISMIC
SOURCE TYPE SEISMIC SOURCE DESCRIPTION Maximum Moment Magnitude, M Slip Rate, SR (mm/year)
A Faults that are capable of producing large magnitude events and that M w 7.0 SR w 5
have a high rate of seismic activity
B All faults other than Types A and C M w 7.0 SR t 5
M t 7.0 SR u 2
M w 6.5 SR t 2
C Faults that are not capable of producing large magnitude earthquakes M < 6.5 SR v 2
and that have a relatively low rate of seismic activity
1Subduction sources shall be evaluated on a site-specific basis.
2Both maximum moment magnitude and slip rate conditions must be satisfied concurrently when determining the seismic source type.

235
336 of 341
TABLE 16-I 1997 UNIFORM BUILDING CODE
TABLE 16-K

TABLE 16-ISEISMIC ZONE FACTOR Z


ZONE 1 2A 2B 3 4

Z 0.075 0.15 0.20 0.30 0.40


NOTE: The zone shall be determined from the seismic zone map in Figure 16-2.

TABLE 16-JSOIL PROFILE TYPES


AVERAGE SOIL PROPERTIES FOR TOP 100 FEET (30 480 mm) OF SOIL PROFILE
SOIL PROFILE SOIL PROFILE NAME/GENERIC Shear Wave Velocity, v s Standard Penetration Test, N [or NCH for Undrained Shear Strength, s u psf
TYPE DESCRIPTION feet/second (m/s) cohesionless soil layers] (blows/foot) (kPa)
SA Hard Rock > 5,000
(1,500)

SB Rock 2,500 to 5,000
(760 to 1,500)
SC Very Dense Soil and Soft Rock 1,200 to 2,500 > 50 > 2,000
(360 to 760) (100)
SD Stiff Soil Profile 600 to 1,200 15 to 50 1,000 to 2,000
(180 to 360) (50 to 100)
SE 1 Soft Soil Profile < 600 < 15 < 1,000
(180) (50)
SF Soil Requiring Site-specific Evaluation. See Section 1629.3.1.
1Soil Profile Type S
E also includes any soil profile with more than 10 feet (3048 mm) of soft clay defined as a soil with a plasticity index, PI > 20, wmc w 40 percent
and s u < 500 psf (24 kPa). The Plasticity Index, PI, and the moisture content, wmc , shall be determined in accordance with approved national standards.

TABLE 16-KOCCUPANCY CATEGORY


SEISMIC SEISMIC WIND
IMPORTANCE IMPORTANCE1 IMPORTANCE
OCCUPANCY CATEGORY OCCUPANCY OR FUNCTIONS OF STRUCTURE FACTOR, I FACTOR, Ip FACTOR, Iw
1. Essential Group I, Division 1 Occupancies having surgery and emergency treatment 1.25 1.50 1.15
facilities2 areas
Fire and police stations
Garages and shelters for emergency vehicles and emergency aircraft
Structures and shelters in emergency-preparedness centers
Aviation control towers
Structures and equipment in government communication centers and other
facilities required for emergency response
Standby power-generating equipment for Category 1 facilities
Tanks or other structures containing housing or supporting water or other
fire-suppression material or equipment required for the protection of Category
1, 2 or 3 structures
2. Hazardous Group H, Divisions 1, 2, 6 and 7 Occupancies and structures therein housing or 1.25 1.50 1.15
facilities supporting toxic or explosive chemicals or substances
Nonbuilding structures housing, supporting or containing quantities of toxic or
explosive substances that, if contained within a building, would cause that
building to be classified as a Group H, Division 1, 2 or 7 Occupancy
3. Special Group A, Divisions 1, 2 and 2.1 Occupancies 1.00 1.00 1.00
occupancy Buildings housing Group E, Divisions 1 and 3 Occupancies with a capacity
structures3 greater than 300 students
Buildings housing Group B Occupancies used for college or adult education
with a capacity greater than 500 students
Group I, Divisions 1 and 2 Occupancies with 50 or more resident incapacitated
patients, but not included in Category 1
Group I, Division 3 Occupancies
All structures with an occupancy greater than 5,000 persons
Structures and equipment in power-generating stations, and other public utility
facilities not included in Category 1 or Category 2 above, and required for
continued operation
4. Standard All structures housing occupancies or having functions not listed in Category 1.00 1.00 1.00
occupancy 1, 2 or 3 and Group U Occupancy towers
structures3
5. Miscellaneous Group U Occupancies except for towers 1.00 1.00 1.00
structures
1The limitation of I for panel connections in Section 1633.2.4 shall be 1.0 for the entire connector.
p
2Structural observation requirements are given in Section 1702.
3For anchorage of machinery and equipment required for life-safety systems, the value of I shall be taken as 1.5.
p

230
337 of 341
CHAP. 16, DIV. IV
1630.1.2 1997 UNIFORM BUILDING CODE
1630.3.2

and strength of elements, which are significant to the distribution 2. Method B: The fundamental period T may be calculated us-
of forces, and shall represent the spatial distribution of the mass ing the structural properties and deformational characteristics of
and stiffness of the structure. In addition, the model shall comply the resisting elements in a properly substantiated analysis. The
with the following: analysis shall be in accordance with the requirements of Section
1630.1.2. The value of T from Method B shall not exceed a value
1. Stiffness properties of reinforced concrete and masonry ele-
30 percent greater than the value of T obtained from Method A in
ments shall consider the effects of cracked sections.
Seismic Zone 4, and 40 percent in Seismic Zones 1, 2 and 3.
2. For steel moment frame systems, the contribution of panel The fundamental period T may be computed by using the fol-
zone deformations to overall story drift shall be included. lowing formula:
1630.1.3 PD effects. The resulting member forces and moments
and the story drifts induced by PD effects shall be considered in
the evaluation of overall structural frame stability and shall be
evaluated using the forces producing the displacements of DS . PD
T + 2p
n

i+1
wi di 2 B g
n

i+1
fi di (30-10)

need not be considered when the ratio of secondary moment to pri- The values of fi represent any lateral force distributed approxi-
mary moment does not exceed 0.10; the ratio may be evaluated for mately in accordance with the principles of Formulas (30-13),
any story as the product of the total dead, floor live and snow load, (30-14) and (30-15) or any other rational distribution. The elastic
as required in Section 1612, above the story times the seismic drift deflections, i , shall be calculated using the applied lateral
in that story divided by the product of the seismic shear in that forces, fi .
story times the height of that story. In Seismic Zones 3 and 4, PD
need not be considered when the story drift ratio does not exceed 1630.2.3 Simplified design base shear.
0.02/R. 1630.2.3.1 General. Structures conforming to the requirements
1630.2 Static Force Procedure. of Section 1629.8.2 may be designed using this procedure.
1630.2.3.2 Base shear. The total design base shear in a given
1630.2.1 Design base shear. The total design base shear in a direction shall be determined from the following formula:
given direction shall be determined from the following formula:
3.0 C a
Cv I V + W (30-11)
V + W (30-4) R
R T
where the value of Ca shall be based on Table 16-Q for the soil pro-
The total design base shear need not exceed the following: file type. When the soil properties are not known in sufficient
detail to determine the soil profile type, Type SD shall be used in
2.5 C a I (30-5) Seismic Zones 3 and 4, and Type SE shall be used in Seismic Zones
V + W
R 1, 2A and 2B. In Seismic Zone 4, the Near-Source Factor, Na , need
The total design base shear shall not be less than the following: not be greater than 1.3 if none of the following structural irregular-
ities are present: Type 1, 4 or 5 of Table 16-L, or Type 1 or 4 of
V + 0.11 C a I W (30-6) Table 16-M.
In addition, for Seismic Zone 4, the total base shear shall also 1630.2.3.3 Vertical distribution. The forces at each level shall
not be less than the following: be calculated using the following formula:
0.8 ZN v I 3.0 C a
V + W (30-7) Fx + wi (30-12)
R R
where the value of Ca shall be determined in Section 1630.2.3.2.
1630.2.2 Structure period. The value of T shall be determined
from one of the following methods: 1630.2.3.4 Applicability. Sections 1630.1.2, 1630.1.3, 1630.2.1,
1630.2.2, 1630.5, 1630.9, 1630.10 and 1631 shall not apply when
1. Method A: For all buildings, the value T may be approxi- using the simplified procedure.
mated from the following formula:
EXCEPTION: For buildings with relatively flexible structural
systems, the building official may require consideration of PD effects
T + C t (h n) 34 (30-8) and drift in accordance with Sections 1630.1.3, 1630.9 and 1630.10. Ds
shall be prepared using design seismic forces from Section 1630.2.3.2.
WHERE: Where used, DM shall be taken equal to 0.01 times the story
Ct = 0.035 (0.0853) for steel moment-resisting frames. height of all stories. In Section 1633.2.9, Formula (33-1) shall read
3.0 C a
Ct = 0.030 (0.0731) for reinforced concrete moment-resist- Fpx = w px and need not exceed 1.0 Ca wpx , but shall not be
ing frames and eccentrically braced frames. R
less than 0.5 Ca wpx. R and Wo shall be taken from Table 16-N.
Ct = 0.020 (0.0488) for all other buildings.
1630.3 Determination of Seismic Factors.
Alternatively, the value of Ct for structures with concrete or ma-
1630.3.1 Determination of Wo . For specific elements of the
sonry shear walls may be taken as 0.1/ A c (For SI: 0.0743 A c structure, as specifically identified in this code, the minimum
for Ac in m2). design strength shall be the product of the seismic force over-
The value of Ac shall be determined from the following for- strength factor Wo and the design seismic forces set forth in Sec-
mula: tion 1630. For both Allowable Stress Design and Strength Design,
the Seismic Force Overstrength Factor, Wo , shall be taken from
A c + SA e 0.2 ) (D eh n) 2 (30-9) Table 16-N.
1630.3.2 Determination of R. The notation R shall be taken from
The value of De /hn used in Formula (30-9) shall not exceed 0.9. Table 16-N.
214
338 of 341
REFERENCE FOR WIND SPEED

DUBAI WIND CODE

Dubai Municipality

2013

339 of 341
3.1.2. Basic wind velocity

The basic wind velocity is the value of the 10-min. averaged wind velocities measured at 10-
m height in an open field that has mean reccurance interval of 50 years (i.e., the annual
probability of exceedance = 0.02). The basic wind velocity for Dubai has been estimated to be
Vb = 30 m/s (108 km/h)., the basic wind velocity of 30 m/s calculated for averaging time of
10-min. corresponds to a basic wind velocity of 45 m/s (160 km/h) for averaging time of 3-
sec. Although studies shows that dominant winds are from the north and the west, in light of
all the other uncertainties that are discussed in the next section, the wind directionality is not
considered as a factor in the calculation of wind loads.

6
340 of 341
Studies have shown that for extreme cases the synoptic winds still control the design [5].
Also, the comparison of velocity profiles in several codes does not suggest any major flaw in
extending the log law beyond 200m , which is the limit in Eurocode, in light of many other
more pressing uncertainties that surface in the quantification of wind velocity profiles [5,6].

3.1.2. Basic wind velocity

The basic wind velocity is the value of the 10-min. averaged wind velocities measured at 10-
m height in an open field that has mean reccurance interval of 50 years (i.e., the annual
probability of exceedance = 0.02). The basic wind velocity for Dubai has been estimated from
the analysis of wind velocities recoerded at the Dubai International Airport during the last 25
years. Figure 3.1 shows the recorded wind velocities and wind directions, and their
corresponding histograms. Assuming that the distribution function of extreme wind speeds is
asympthotic to the Fisher-Tippet (i.e., Type 1) distribution, and matching a Gumbel
distrbution to the ppeak values,, as shown in Figure 3.2, the basic wind velocity for Dubai is
determined to be Vb = 25 m/s (90 km/h). Based on the relationship developed by Durst [7]
between the short-time and hourly averaged wind velocities (as shown in Fig. 3.3), the basic
wind velocity of 25 m/s calculated for averaging time of 10-min. corresponds to a basic wind
velocity of 38 m/s (137 km/h) for averaging time of 3-sec. Although Fig. 3.1 shows that
dominant winds are from the north and the west, in light of all the other uncertainties that are
discussed in the next section, the wind directionality is not considered as a factor in the
calculation of wind loads.

6
341 of 341

Das könnte Ihnen auch gefallen