Title page

Alcatel-Lucent 9311
Macro V2 Node B Outdoor | UA08.1
Corrective Maintenance
NN-20500-011
Issue 09.07 | January 2013

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Use pursuant to applicable agreements

Legal notice

Legal notice

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.

The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2013 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Contents

About this document


Purpose .......................................................................................................................................................................................... xiii
xiii

Reason for reissue ...................................................................................................................................................................... xiii


xiii

New in this release .................................................................................................................................................................... xiii


xiii

Intended audience ...................................................................................................................................................................... xiv


xiv

Supported systems ..................................................................................................................................................................... xiv


xiv

How to use this document ....................................................................................................................................................... xiv


xiv

Safety information ..................................................................................................................................................................... xiv


xiv

Prerequisites ................................................................................................................................................................................. xiv


xiv

Conventions used ....................................................................................................................................................................... xiv


xiv

Related information .................................................................................................................................................................... xv


xv

Document support ...................................................................................................................................................................... xvi


xvi

Technical support ....................................................................................................................................................................... xvi


xvi

How to order ................................................................................................................................................................................ xvi


xvi

How to comment ........................................................................................................................................................................ xvi


xvi

1 Roadmap to Conventional Base Station documentation

Overview ...................................................................................................................................................................................... 1-1


1-1

Roadmap to Conventional Base Station documentation ............................................................................................ 1-2


1-2

2 Safety statements

Overview ...................................................................................................................................................................................... 2-1


2-1

Structure of safety statements ............................................................................................................................................... 2-2


2-2

3 Corrective maintenance activity

Overview ...................................................................................................................................................................................... 3-1


3-1
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary iii
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Contents

....................................................................................................................................................................................................................................
Corrective maintenance activity .......................................................................................................................................... 3-2
3-2

4 9311 Macro V2 OD introduction

Overview ...................................................................................................................................................................................... 4-1


4-1

9311 Macro V2 OD introduction ........................................................................................................................................ 4-2


4-2

5 9311 Macro V2 OD hardware presentation

Overview ...................................................................................................................................................................................... 5-1


5-1

9311 Macro V2 OD hardware presentation ..................................................................................................................... 5-2


5-2

6 Checking the door alarm

Overview ...................................................................................................................................................................................... 6-1


6-1

Checking the door alarm ........................................................................................................................................................ 6-2


6-2

7 9311 Macro V2 OD power down and power up procedures

Overview ...................................................................................................................................................................................... 7-1


7-1

Powering down a 9311 Macro V2 OD .............................................................................................................................. 7-2


7-2

Powering up a 9311 Macro V2 OD .................................................................................................................................... 7-4


7-4

8 9311 Macro V2 OD corrective maintenance procedures

Overview ...................................................................................................................................................................................... 8-1


8-1

Replacing the digital shelf equipment

Overview ...................................................................................................................................................................................... 8-3


8-3

Replacing the Channel Element Module (CEM) .......................................................................................................... 8-4


8-4

Replacing the Core Controller Module (CCM) ........................................................................................................... 8-13


8-13

Replacing the GPS interface and Alarm Module (GPSAM) .................................................................................. 8-23
8-23

Replacing the TRansceiver Module (TRM) ................................................................................................................. 8-27


8-27

Replacing the GPxOIM ........................................................................................................................................................ 8-35


8-35

Replacing the C2OIM ........................................................................................................................................................... 8-40


8-40

Replacing the digital backplane of the 9311 Macro V2 OD ................................................................................... 8-45


8-45

Replacing the optional xCCM radio interface Board (xCOB) ............................................................................... 8-50
8-50
....................................................................................................................................................................................................................................
iv Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Contents

....................................................................................................................................................................................................................................
Replacing the RF block equipment

Overview ................................................................................................................................................................................... 8-55


8-55

Replacing the Dual Duplexer Module (DDM) ............................................................................................................ 8-56


8-56

Replacing the Multi-Carrier Power Amplifier module (MCPA) or Single-Carrier Power Amplifier
module (SCPA) ............................................................................................................................................................... 8-64
8-64

Replacing the Tx Splitter ..................................................................................................................................................... 8-76


8-76

Replacing a TRDU ................................................................................................................................................................. 8-80


8-80

Replacing the cooling system equipment

Overview ................................................................................................................................................................................... 8-87


8-87

Replacing the air filter .......................................................................................................................................................... 8-88


8-88

Replacing the ECU control board .................................................................................................................................... 8-91


8-91

Replacing a fan ........................................................................................................................................................................ 8-95


8-95

Replacing the ECU ASSY S180 ....................................................................................................................................... 8-99


8-99

Replacing the power system equipment

Overview ................................................................................................................................................................................. 8-102


8-102

Replacing the ADU module ............................................................................................................................................. 8-103


8-103

Replacing the Cabinet Control Unit (CCU) module ............................................................................................... 8-107


8-107

Replacing the UCPS rectifiers ......................................................................................................................................... 8-110


8-110

Replacing the rectifier rack and DDU .......................................................................................................................... 8-112


8-112

Replacing the batteries ....................................................................................................................................................... 8-117


8-117

Replacing the optional equipment

Overview ................................................................................................................................................................................. 8-125


8-125

Replacing the Manufacturing Commissioning and Alarm (MCA) module .................................................... 8-126
8-126

Replacing the alarm protection module ....................................................................................................................... 8-131


8-131

Replacing the double TMA module .............................................................................................................................. 8-134


8-134

Replacing the light TMA/AISG TMA module ......................................................................................................... 8-139


8-139

Replacing the Power Amplifier InterCOnnection (PA ICO) module ................................................................ 8-145
8-145

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary v
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Contents

....................................................................................................................................................................................................................................
Replacing the Radio Frequency InterCOnnection (RF ICO) module ............................................................... 8-149
8-149

Replacing the door gaskets ............................................................................................................................................... 8-152


8-152

Replacing the foam gaskets .............................................................................................................................................. 8-156


8-156

Replacing the door lock ..................................................................................................................................................... 8-160


8-160

Replacing the User ICO module .................................................................................................................................... 8-164


8-164

A Product conformance statements

Overview ..................................................................................................................................................................................... A-1


A-1

European regulatory requirement compliance .............................................................................................................. A-2


A-2

North American regulatory requirements compliance ............................................................................................... A-4


A-4

Compliances for other regions/countries ........................................................................................................................ A-8


A-8

Operational conditions ........................................................................................................................................................... A-9


A-9

Cable specifications .............................................................................................................................................................. A-10


A-10

Product labelling .................................................................................................................................................................... A-11


A-11

Index

....................................................................................................................................................................................................................................
vi Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
List of tables

1 Generic terms .............................................................................................................................................................. xiv


xiv

8-1 Downloading error sub-causes ........................................................................................................................... 8-73

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary vii
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
List of tables

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
viii Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
List of figures

1-1 Roadmap to Conventional Base Station documentation ............................................................................. 1-3

4-1 9311 Macro V2 OD outside view ........................................................................................................................ 4-3

5-1 9311 Macro V2 OD general view with PA, DDM ....................................................................................... 5-3

5-2 9311 Macro V2 OD general view with TRDU ............................................................................................... 5-4

5-3 9311 Macro V2 OD 2100 cabinet layout .......................................................................................................... 5-5

5-4 9311 Macro V2 OD 2100 bulkhead view ......................................................................................................... 5-6

5-5 9311 Macro V2 OD AC/DC variant cabinet layout ...................................................................................... 5-8

8-1 iCEM 64 front panel ................................................................................................................................................. 8-5


8-5

8-2 iCEM-2 64 front panel ............................................................................................................................................. 8-6

8-3 iCEM 128 front panel .............................................................................................................................................. 8-7

8-4 iCEM-2 128 front panel .......................................................................................................................................... 8-8

8-5 xCEM front panel ...................................................................................................................................................... 8-9


8-9

8-6 eCEM front panel .................................................................................................................................................... 8-10


8-10

8-7 CCM front panel ...................................................................................................................................................... 8-14


8-14

8-8 iCCM front panel .................................................................................................................................................... 8-15


8-15

8-9 iCCM-2 front panel ................................................................................................................................................ 8-16


8-16

8-10 xCCM front panel in configuration xCCM-4E1 .......................................................................................... 8-17

8-11 xCCM front panel in configuration xCCM-GE ........................................................................................... 8-18

8-12 GPSAM front panel ................................................................................................................................................ 8-24

8-13 TRM front panel ...................................................................................................................................................... 8-28


8-28

8-14 iTRM front panel ..................................................................................................................................................... 8-29


8-29

8-15 xTRM front panel ................................................................................................................................................... 8-30


8-30

8-16 xTRM-2 front panel ............................................................................................................................................... 8-31

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary ix
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
List of figures

....................................................................................................................................................................................................................................
8-17 GPxOIM front panel (with C2OIM inserted) ............................................................................................... 8-36

8-18 Color code for Multi-Mode SFP transceivers ............................................................................................... 8-38

8-19 C2OIM-GM front panel ........................................................................................................................................ 8-41

8-20 C2OIM-GS front panel ......................................................................................................................................... 8-42

8-21 Color code for Multi-Mode SFP transceivers ............................................................................................... 8-44

8-22 Digital rack front panel ......................................................................................................................................... 8-46

8-23 DC connector ............................................................................................................................................................ 8-47


8-47

8-24 Fixing screws of the digital backplane ............................................................................................................ 8-48

8-25 xCOB and xCCM modules ................................................................................................................................ 8-51

8-26 xCOB front panel ................................................................................................................................................... 8-53


8-53

8-27 DDM front panel ..................................................................................................................................................... 8-57


8-57

8-28 DDM-2/DDM-E 900/DDM-P 900 front panel ............................................................................................. 8-58

8-29 AISG DDM front panel ........................................................................................................................................ 8-58

8-30 A bad assembly of antenna cables ................................................................................................................... 8-61

8-31 A correct assembly of antenna cables .............................................................................................................. 8-62

8-32 MCPA front panel ................................................................................................................................................... 8-65


8-65

8-33 MCPA 60W-A front panel .................................................................................................................................... 8-66

8-34 MCPA 60W-B front panel .................................................................................................................................... 8-67

8-35 SCPA 900 55W front panel .................................................................................................................................. 8-68

8-36 Cajun MCPA download - maintenance actions ............................................................................................ 8-75

8-37 Tx Splitter front panel ........................................................................................................................................... 8-76


8-76

8-38 TRDU6021 front panel ....................................................................................................................................... 8-81

8-39 TRDU60-21B front panel .................................................................................................................................... 8-82

8-40 Power switch on the TRDU front panel .......................................................................................................... 8-84

8-41 Air filter replacement ............................................................................................................................................. 8-89


8-89

8-42 ECU control board (connectors) ........................................................................................................................ 8-93

8-43 Fan replacement ....................................................................................................................................................... 8-96


8-96
....................................................................................................................................................................................................................................
x Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
List of figures

....................................................................................................................................................................................................................................
8-44 ECU ASSY S180 .................................................................................................................................................. 8-100

8-45 ADU module replacement ................................................................................................................................. 8-105

8-46 CCU module replacement ................................................................................................................................. 8-108

8-47 UCPS rectifier module ........................................................................................................................................ 8-111

8-48 Rectifier rack and DDU board ......................................................................................................................... 8-114

8-49 Batteries cabling .................................................................................................................................................... 8-123


8-123

8-50 MCA module replacement ................................................................................................................................ 8-128

8-51 Alarm protection module front panel ............................................................................................................ 8-132

8-52 TMA module set-up diagram ........................................................................................................................... 8-135

8-53 Light TMA module set-up diagram ............................................................................................................... 8-140

8-54 Light TMA module .............................................................................................................................................. 8-143

8-55 PA ICO module ...................................................................................................................................................... 8-147


8-147

8-56 RF ICO module ..................................................................................................................................................... 8-150


8-150

8-57 Door gasket replacement .................................................................................................................................... 8-154

8-58 Foam gasket replacement .................................................................................................................................. 8-158

8-59 Removal of the door lock .................................................................................................................................. 8-161

8-60 Reinsertion of the door lock ............................................................................................................................. 8-162

8-61 User ICO module front panel ........................................................................................................................... 8-165

8-62 Disconnection of the User ICO supply cable from the DDU ............................................................... 8-166

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary xi
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
List of figures

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
xii Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
About this document
About this document

Purpose
The purpose of this document is to describe the corrective maintenance procedures
applicable to the Alcatel-Lucent 9311 Macro V2 Node B Outdoor. Its short name is 9311
Macro V2 OD.

Reason for reissue


The reissue reasons are:

Issue number Issue date Reason for reissue


09.07 January 2013 Standard issue
09.06 November 2012 Standard issue
09.05 October 2012 Standard issue
09.04 March 2012 Preliminary issue
09.03 November 2011 Preliminary issue
09.02 September 2011 Preliminary issue
09.01 June 2011 Draft issue

New in this release


New features:
121167 Support of remote MC-TRX from 9100 MBS.
Other changes:
Mixity restriction: TRDU mixity is not allowed inside a cluster.
Updated documentation roadmap.
Important! The availability of the features listed above on the hardware equipment
should be checked with your Alcatel-Lucent representative.

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary xiii
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
About this document

....................................................................................................................................................................................................................................
Intended audience
The audience for this document is Operations and maintenance personnel, and for those
who want to know the principles of 9311 Macro OD corrective maintenance.

Supported systems
This document applies to Alcatel-Lucent W-CDMA UA08.1 system release.

How to use this document


No specific recommendation applies regarding the way readers should read this
document.

Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.

Prerequisites
It is recommended that readers become familiar with the following publications:
Alcatel-Lucent 9311 Macro V2 Node B Outdoor documentation:
Technical Description, NN-20500-004
Preventive Maintenance, NN-20500-010

Conventions used
Vocabulary conventions
For a list of the terms used in this document, see Alcatel-Lucent W-CDMA System -
Terminology, NN-20500-002
This document uses some terms generically.

Table 1 Generic terms

Generic term Used for


CCM CCM/iCCM/iCCM-2/xCCM
CEM iCEM/iCEM-2/xCEM/eCEM
TRM TRM/iTRM/xTRM/xTRM-2
DDM DDM/DDM-2/DDM-E 900/DDM-P
900/AISG DDM

....................................................................................................................................................................................................................................
xiv Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
About this document

....................................................................................................................................................................................................................................
Table 1 Generic terms (continued)

Generic term Used for


MCPA MCPA 850/MCPA 2100/MCPA-2
2100/MCPA-3 2100/MCPA 60W 850/MCPA
60W 2100
SCPA SCPA 900 55W
TRDU TRDU60-21/TRDU60-21B

Typographical conventions
The following typographical conventions are used in this document:

Appearance Description
IP reference, reference number Related document that is referenced in the document
Bold text or Italicized text Emphasized information
graphical user interface text Text that is displayed in a graphical user interface or
in a hardware label

Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:

Refer to this document At this location For more information on


Alcatel-Lucent W-CDMA http://support.alcatel-lucent. Terms used in Alcatel-Lucent
System - Terminology, com. 9300 W-CDMA documents.
NN-20500-002
Alcatel-Lucent 9353 http://support.alcatel-lucent. Alarm descriptions and
Wireless Management com. maintenance actions required
System - Node B Alarms for Alcatel-Lucent Node Bs
Reference Guide for 9311,
9312, 9322, 9326, 9332
Node B, NN-20500-018P1
Alcatel-Lucent 9353 http://support.alcatel-lucent. Performing Graphical User
Wireless Management com. Interface (GUI) commands
System - User Guide, available in the Wireless
NN-20500-032 Management System (WMS)
solution.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary xv
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
About this document

....................................................................................................................................................................................................................................

Refer to this document At this location For more information on


Alcatel-Lucent 9100 and http://support.alcatel-lucent. Performing the Node B
93xx Node B - com. installation, commissioning
Commissioning and Fault and maintenance tasks using
Management User Manual: the Node B TIL (Terminal for
TIL, NN-20500-019 Local Installation) tool.
Alcatel-Lucent W-CDMA http://support.alcatel-lucent. Safety guidelines and the
safety guide, 401-382-880 com. catalog of hazard statements
that appear in the
Alcatel-Lucent UMTS
customer documents.

Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
1-888-582-3688 (for the United States)
1-630-224-2485 (for all other countries)

Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.

How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)

How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).

....................................................................................................................................................................................................................................
xvi Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
1 1oadmap to Conventional
R
Base Station
documentation

Overview
Purpose
This chapter provides the roadmap for Conventional Base Station documentation.

Contents

Roadmap to Conventional Base Station documentation 1-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 1-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................

Roadmap to Conventional Base Station documentation


Overall roadmap
For the roadmap relating to the full documentation collection, see:
Alcatel-Lucent W-CDMA System - Document Collection Overview, NN-20500-050
For the Access Network Elements Overview, see:
Alcatel-Lucent W-CDMA System - Access Network Elements Overview,
NN-20500-233

....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................

Figure 1-1 Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 1-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Roadmap to Conventional Base Station documentation Roadmap to Conventional Base Station documentation

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
1-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
2 Safety statements
2

Overview
Purpose
This chapter provides information on the structure of safety statements which may arise
in the course of your work.

Contents

Structure of safety statements 2-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 2-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Safety statements Structure of safety statements

....................................................................................................................................................................................................................................

Structure of safety statements


Overview
This topic describes the components of safety statements that appear in this document.

General structure
Safety statements include the following structural elements:

B C D
CAUTION

MP L E
Lifting hazard E F

SA
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
G
Always use three people or a lifting device to transport
and position this equipment. [ABC123]
H
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
(optional)

....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Safety statements Structure of safety statements

....................................................................................................................................................................................................................................
Signal words
The signal words identify the hazard severity levels as follows:

Signal word Meaning


DANGER Indicates an extremely hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE Indicates a hazardous situation not related to personal injury.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 2-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Safety statements Structure of safety statements

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
3 3 orrective maintenance
C
activity

Overview
Purpose
This part describes the corrective maintenance activity applicable to the 9311 Macro OD
cabinets.

Contents

Corrective maintenance activity 3-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 3-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Corrective maintenance activity


Corrective maintenance
The network maintenance is based on the supervision of the network, by using the OAM
graphical interface. For more information, refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, NN-20500-032.
It is also based on the identification and replacement of faulty items of equipment, using
the alarms.
The process is divided into the two following steps:
Locating and identifying the faulty items of equipment, by using the information
provided in Alcatel-Lucent 9353 Wireless Management System - Node B Alarms
Reference Guide for 9311, 9312, 9322, 9326, 9332 Node B, NN-20500-018P1.
Replacing the faulty items of equipment, by using the replacement procedures given
in this guide.

Replacing the digital shelf equipment

Procedure Order code RoHS Node B Impact on


compliant variant service
order code
Replacing the Channel iCEM 64: iCEM 64: NA 9311 Macro V2 Service reduction
Element Module (CEM) NTUM00CA OD or loss of service
(p. 8-4) iCEM 128: iCEM 128: NA for all types of
NTUM00DA CEMs

iCEM-2 64: iCEM-2 64:


NTUM00CB NTUM00CG
iCEM-2 128: iCEM-2 128:
NTUM00DB NTUM00DG
xCEM board xCEM board
without without Capacity
Capacity License:
License: NA 300985710
eCEM board 3JR20069AA

....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure Order code RoHS Node B Impact on


compliant variant service
order code
Replacing the Core Controller CCM - 48 V CCM - 48 V DC: 9311 Macro V2 Loss of service
Module (CCM) (p. 8-13) DC: NA OD
NTGY25AA
iCCM -48 V DC iCCM -48 V DC
with filler: with filler: NA
NTUM99TA
iCCM-2 -48 V PCBA: iCCM-2
DC with filler: with software:
NTUM99TM NTUM99TS
xCCM kit xCCM kit 8-port
8-port PCM PCM with filler:
with filler: NA NTUM99YA
PCBA: xCCM PCBA: xCCM
8-port PCM: 8-port PCM:
NA NTUM25AM
xCCM case 50
mm:
NTUM26AM
Replacing the optional xCCM PCBA xCOB 3JR20003AB 9311 Macro V2
radio interface Board (xCOB) (xCCM Optical OD
(p. 8-50) Board)
Replacing the GPS interface GPSAM: GPSAM: 9311 Macro V2 DC power down
and Alarm Module (GPSAM) NTUM24AA NTUM24AF OD
(p. 8-23)
Replacing the Core Controller TRM 2100: TRM 2100: NA 9311 Macro V2 Telecom outage
Module (CCM) (p. 8-13) NTUM10AA OD 2100 on impacted
iTRM 2100: iTRM 2100: sector/frequency
NTUM17AA NTUM17AF
xTRM 2100: xTRM 2100:
NTUM17AM NTUM17AS
xTRM-2 2100: xTRM-2 2100:
NA 3JR21008AA
xTRM 900: NA xTRM 900: 9311 Macro V2
NTBY17EA OD 900
xTRM 850: NA xTRM 850: 9311 Macro V2
NTBY17BA OD 850

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 3-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure Order code RoHS Node B Impact on


compliant variant service
order code
Replacing the GPxOIM - NTU718AK 9311 Macro V2 None
(p. 8-35) OD
Replacing the C2OIM - C2OIM-GM: 9311 Macro V2 None
(p. 8-40) NTU717AJ OD
- C2OIM-GS:
NTU717AG

Replacing the RF block equipment

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the AISG DDM 2100: AISG DDM 2100: 9311 Macro V2 OD Telecom outage on
Dual Duplexer NA NTUM40AM 2100 impacted
Module (DDM) DDM 2100: DDM 2100: NA sector/frequency.
(p. 8-56) NTUM40AA Radiation hazard

DDM-2 2100: DDM-2 2100:


NTU747AA NTU747AF
DDM-E 900: NA DDM-E 900: 9311 Macro V2 OD
NTUM40JA 900
DDM-P 900: NA DDM-P 900:
NTUM40JM
DDM 850: NA DDM 850: 9311 Macro V2 OD
NTUM40HA 850

....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the MCPA 2100: MCPA 2100: NA 9311 Macro V2 OD Telecom outage.
Multi-Carrier NTUM30AA 2100 Radiation hazard
Power Amplifier MCPA 1900: MCPA 1900: NA 9311 Macro V2 OD
module (MCPA) or NTUM30PA 1900
Single-Carrier
Power Amplifier MCPA-2 2100: MCPA-2 2100: NA 9311 Macro V2 OD
module (SCPA) NTUM30CA 2100
(p. 8-64) MCPA-3 2100: MCPA-3 2100:
NTUM90EA NTUM90EA
MCPA 60W-B MCPA 60W-B
2100: NA 2100: NTUM30WA
MCPA 60W-A MCPA 60W-A
2100: NA 2100: NTUM30FM
MCPA 850: NA MCPA 850: 9311 Macro V2 OD
NTUM30EA 850
SCPA 900 55W: SCPA 900 55W: 9311 Macro V2 OD
NA NTUM30GA 900
Replacing the Tx Tx Splitter: Tx Splitter-2: 9311 Macro V2 OD Telecom outage.
Splitter (p. 8-76) NTUM50AA NTUM50AF Radiation hazard
Replacing a TRDU60-21: TRDU: 9311 Macro V2 OD Telecom outage.
TRDU (p. 8-80) 3JR21012AB Radiation hazard
TRDU60-21B:
3JR09305AA

Replacing the power system equipment

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the ADU: NTT970AA ADU: NTT970AF 9311 Macro V2 OD Service is lost if the
ADU module ac box breaks down
(p. 8-103) during replacement
Replacing the UCPS UMTS/GSM UCPS UMTS/GSM 9311 Macro V2 OD Service is lost if the
Cabinet Control CCU: NTUM44AA CCU: NTUM44AF ac box breaks down
Unit (CCU) during replacement
module (p. 8-107)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 3-5
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the UCPS Rectifier, UCPS Rectifier, 9311 Macro V2 OD None
UCPS rectifiers 1000 W: 1000 W:
(p. 8-110) NTW703BB NTW703BF
UCPS Rectifier, UCPS Rectifier,
1400 W: 1400 W:
NTN070BA NTN070BF
Replacing the UCPS Rectifier UCPS Rectifier 9311 Macro V2 OD Service is lost if the
rectifier rack and shelf with DDU: shelf with DDU: ac box breaks down
DDU (p. 8-112) NTN066AY NTN066AA during replacement
This code includes: This code includes:
UCPS Shelf: UCPS Shelf:
NTW703AA NTW703AF
UCPS GSM/UMTS UCPS GSM/UMTS
DDU: NTN070DA DDU: NTN070DF
Replacing the NTN091MH NTUM92GF 9311 Macro V2 OD Service is lost if the
batteries (p. 8-117) (Batteries string (Batteries string ac box breaks down
SBS60) SBS60) during replacement
NTN091MD A0658890
(Batteries string (Batteries string
SBS40) SBS40)
NTN091MA NTN091MF
(Batteries string (Batteries string
SBS15) SBS15)

Replacing the cooling system equipment

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the air - - 9311 Macro V2 OD None
filter (p. 8-88)
Replacing the NTN071GA NTN071GF 9311 Macro V2 OD None
ECU control board
(p. 8-91)
Replacing a fan NTN07105 Fan Support ASSY 9311 Macro V2 OD Service is lost if the
(p. 8-95) S180: NTT971GF Node B is powered
down

....................................................................................................................................................................................................................................
3-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the NTT971CA NTT971CF 9311 Macro V2 OD Service is lost if the
ECU ASSY S180 ac box breaks down
(p. 8-99) during replacement

Replacing miscellaneous equipment

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the NTBY90AA NTBY90AF 9311 Macro V2 OD None
Manufacturing
Commissioning and
Alarm (MCA)
module (p. 8-126)
Replacing the NTUM32BA - 9311 Macro V2 OD Telecom outage.
double TMA Radiation hazard
module (p. 8-134)
Replacing the light NTUM32CB NTUM32CG 9311 Macro V2 OD Telecom outage.
TMA/AISG TMA AISG TMA: NA AISG TMA: 9311 Macro V2 OD Radiation hazard
module (p. 8-139) NTUM32CM
Replacing the NTN020HM NTU720HM 9311 Macro V2 OD None
Power Amplifier
InterCOnnection
(PA ICO) module
(p. 8-145)
Replacing the NTN020HG NTU720HG 9311 Macro V2 OD Service is lost if the
Radio Frequency ac box breaks down
InterCOnnection during replacement
(RF ICO) module
(p. 8-149)
Replacing the door - - 9311 Macro V2 OD None
gaskets (p. 8-152)
Replacing the - - 9311 Macro V2 OD None
foam gaskets
(p. 8-156)
Replacing the door NTN071BA NTT991BF (MD1) 9311 Macro V2 OD None
lock (p. 8-160)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 3-7
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure Order code RoHS compliant Node B variant Impact on


order code service
Replacing the NTT970BA NTT970BF 9311 Macro V2 OD Service is lost when
User ICO module the ADU breaks
(p. 8-164) down during
replacement

Notes:
1. Manufacture Discontinue

Description of a replacement procedure


A replacement procedure is divided into the following parts:
Title
Main body with following information:
Intervention time
Tools required
Step-by-step actions
One or more figures showing the Field Replaceable Unit (FRU) schematically

Intervention restrictions
There may be a lapse of time between the identification of the alarm at the Access OAM
Graphic User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by
telephone) before an on-site intervention, in the following cases:
Isolating procedures
Completion of an on-site intervention
Return to service procedure

General personnel safety instructions


The personnel must obey the safety instructions specific to the installation site:
Rules concerning the premises (see instructions posted on site or in the building)
Rules linked to general personnel safety instructions
The personnel working on the cabinet must be authorized to work according to security
standards.

....................................................................................................................................................................................................................................
3-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................
Equipment safety instructions
The 9311 Macro V2 OD normally operates when the external temperature is between
-40C and +50C.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 3-9
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
3-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
4 4311 Macro V2 OD
9
introduction

Overview
Purpose
This part gives an overview of the Alcatel-Lucent 9311Macro V2 Node B Outdoor

Contents

9311 Macro V2 OD introduction 4-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 4-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD introduction 9311 Macro V2 OD introduction

....................................................................................................................................................................................................................................

9311 Macro V2 OD introduction


Introduction
The 9311 Macro V2 OD is an ETSI UMTS Node B element and supports the Iub
interface.
The 9311 Macro V2 OD only supports the Frequency Division Duplex (FDD) mode.
The 9311 Macro V2 OD is responsible for radio transmission/reception from/to one or
more cells to/from the User Equipment (UE).
The 9311 Macro V2 OD provides:
The means of communication between a UE and a network using Transport Channels
Physical layer channels which are necessary to synchronize the downlink and also to
perform cell selection/reselection and hand over preparation
Measurement information to the RNC for radio resource management (hand over,
power control)
The 9311 Macro V2 OD provides up to eight E1/T1 (only T1 for UMTS 850) with
Inversion Multiplexing ATM (IMA) or Drop and Insert capability (fractional E1/T1).
The 9311 Macro V2 OD also supports:
Multi-PCM without IMA
IP
Microwave Packet Radio (MPR)

9311 Macro V2 OD interfaces


The 9311 Macro V2 OD provides the following interfaces:
Uu interface (UMTS User interface): this interface is used between the Node B and
the UE. It is dependent on the technology used on the radio (for example, it can be
W-CDMA or TD/CDMA).
Iub interface (Interface Node B): this interface lies between the RNC and the Node B.
It allows to connect RNCs.

9311 Macro V2 OD cabinet


The 9311 Macro V2 OD cabinet is a single cabinet closed by two doors. It is designed to
ease transport, installation, repair, network growth and flexibility, and to manage diverse
traffic demands.
To increase the Node B capacity, modules are added instead of whole cabinets.
The 9311 Macro V2 OD hardware is High Speed Downlink Packet Access (HSDPA)
ready.

....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD introduction 9311 Macro V2 OD introduction

....................................................................................................................................................................................................................................
The 9311 Macro V2 OD can operate into the following bandwidths:
2100 MHz
900 MHz
850 MHz
2100/900 MHz (dual-band)
2100/850 MHz (dual-band)
The following figure shows an outside view of the 9311 Macro V2 OD cabinet.

Figure 4-1 9311 Macro V2 OD outside view

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 4-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD introduction 9311 Macro V2 OD introduction

....................................................................................................................................................................................................................................
9311 Macro V2 OD modules
The alpha-modules were the first generation of modules delivered by Alcatel-Lucent.
Note: The alpha-CEM is not supported since UA06.0.
Then Alcatel-Lucent delivered a second generation of modules:
iModules (also called beta-modules) and iModules-2
These modules are compatible with existing ones. They are transparent to the user as
they do not provide a capacity change (except for iCEM).
MCPA-2
The MCPA-2 module operates into the 2100 bandwidth.
The third generation of modules delivered by Alcatel-Lucent were the following:
xCCM
xCEM
xTRM
MCPA-3
The MCPA-3 module operates into the 2100 bandwidth.
The last generation of modules delivered by Alcatel-Lucent were the following:
xTRM-2
The latest xTRM generation. The xTRM-2 module operates into the 2100 bandwidth.
MCPA 60W
The latest MCPA generation. The MCPA 60W module operates into the 2100 MHz
and 850 MHz bandwidths.
SCPA 55W
The SCPA 55W module operates into the 900 MHz bandwidth.
DDM-E
The DDM-E module operates into the 900 MHz bandwidth.
DDM-P
The DDM-P module operates into the 900 MHz bandwidth.
eCEM
TRDU
The TRDU module operates into the 2100 bandwidth.

....................................................................................................................................................................................................................................
4-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
5 5311 Macro V2 OD
9
hardware presentation

Overview
Purpose
This part is a hardware presentation of the 9311 Macro V2 OD cabinet types.

Contents

9311 Macro V2 OD hardware presentation 5-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 5-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................

9311 Macro V2 OD hardware presentation


Purpose
This section is a hardware presentation of the 9311 Macro V2 OD cabinets.
Alcatel-Lucent provides the following 9311 Macro V2 OD cabinets:
9311 Macro V2 OD 2100 (standard AC power supplied cabinet)
9311 Macro V2 OD 2100 (AC/DC variant equipped with a DC Connection Block)
9311 Macro V2 OD 900
9311 Macro V2 OD 850 (standard AC power supplied cabinet)
9311 Macro V2 OD 850 (AC/DC variant equipped with a DC Connection Block)
9311 Macro V2 OD 2100/900
9311 Macro V2 OD 2100/850

9311 Macro V2 OD 2100 hardware presentation


The 9311 Macro V2 OD 2100 cabinet is divided into the following compartments:
Upper compartment
Main compartment
Bulkhead
The upper compartment comprises the Environmental Cooling Unit (ECU). The ECU is
an integral part of the Node B cabinet design. It is the cooling unit of the cabinet and is
accessed through the front-hinged access door.
The main compartment is divided into the two following parts.
The left part includes the following elements:
One Power Amplifier InterCO (PA ICO) module
One MCPA shelf (up to six MCPAs or TRDU)
One Radio Frequency InterCO (RF ICO) module
One Dual Duplexer Module shelf (up to three DDMs)
One optional rack which houses one Filler 1 U
One battery space
The right part includes the following elements:
One digital shelf
One power and alarm interconnection (also called User ICO)
One User space which houses four slots (fillers)
One of these slots is dedicated to the CCU module used for RETA system.
One Dual Duplexer Module shelf (up to three DDMs)
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................
One Univity Compact Power System (UCPS) which houses the following modules:
One rectifier shelf (up to five rectifiers)
One DC Distribution Unit (DDU)
One Cabinet Control Unit (CCU)
one AC Distribution Unit (ADU)
The following figure shows the 9311 Macro V2 OD 2100. inside view and layout

Figure 5-1 9311 Macro V2 OD general view with PA, DDM

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 5-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................
Figure 5-2 9311 Macro V2 OD general view with TRDU

....................................................................................................................................................................................................................................
5-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................
Figure 5-3 9311 Macro V2 OD 2100 cabinet layout

Note: The ECU control box is located on the right side of the upper compartment (1).
The bulkhead allows cable connection and lightning protection.
The following figure shows the 9311 Macro V2 OD 2100 bulkhead.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 5-5
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................

Figure 5-4 9311 Macro V2 OD 2100 bulkhead view

9311 Macro V2 OD AC/DC variant hardware presentation


The 9311 Macro V2 OD 2100 is available in an AC/DC variant for customers who want
to power the 9311 Macro V2 OD from an external -48 V DC power supply source. AC
network is still required to activate heating feature of the cabinet and AC Plug option.
The AC/DC variant of the 9311 Macro V2 OD cabinet and the standard AC powered 9311
Macro V2 OD cabinet have a similar compartment layout.
Compared to the standard AC powered cabinet, the AC/DC variant integrates the
following changes:
The internal batteries are removed.
The battery space houses a DC Connection Block.
The rectifiers are removed and replaced by fillers.
....................................................................................................................................................................................................................................
5-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................
The DC input voltage range is -40.5 V up to -57 V DC with the following behaviors:
Limitation associated to the cabinet start up: the DC power supply voltage must be
higher than 52 V to start up the Node B.
Limitation associated to the LVD Threshold: the LVD Threshold is unchanged from
the AC version and is set to -44 V DC. The Node B operates only if the DC power
supply voltage is higher than -44 V at the entry of the Node B.
The following figure shows the inside view of the 9311 Macro V2 ODAC/DC variant.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 5-7
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................

Figure 5-5 9311 Macro V2 OD AC/DC variant cabinet layout

Note: The ECU control box is located on the right side of the upper compartment (1).
The checks and replacement procedures described for the standard AC powered
9311 Macro V2 OD cabinet also apply to the AC/DC variant of the 9311 Macro V2
ODcabinet.

....................................................................................................................................................................................................................................
5-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................
When the cabinet is powered on and in operational state, the corporate LEDs of the UCPS
CCU module have the following behavior: C1 rectangular LED ON (green) and C2
triangular LED ON (red). This is a normal behavior, specific to the AC/DC variant.

9311 Macro V2 OD 900 hardware presentation


The 9311 Macro V2 OD 900 hardware is similar to the 9311 Macro V2 OD 2100, except
for the following components:
The RF block houses the modules that operate in the 900 MHz frequency band. These
modules are the following:
SCPA 900 55W modules
DDM-E 900 and DDM-P 900 modules
The digital shelf houses the xTRM 900 modules

9311 Macro V2 OD 850 hardware presentation


The 9311 Macro V2 OD 850 hardware is similar to the 9311 Macro V2 OD 2100, except
for the following components:
the RF block houses the modules that operate in the 850 MHz frequency band. These
modules are the following:
MCPA 850 modules
DDM 850 Modules
the digital shelf houses the xTRM 850 modules

9311 Macro V2 OD 2100/900 hardware presentation


The 9311 Macro V2 OD 2100/900 hardware is similar to the 9311 Macro V2 OD 2100
hardware, with dedicated (bandwidth-specific) and shared modules:
Dedicated modules:
For 2100 MHz: TRM/iTRM/xTRM 2100 + MCPA/MCPA-2/MCPA-3/MCPA
60W 2100 + DDM/DDM-2 2100
For 900 MHz: xTRM 900 + SCPA 55W + DDM-E 900/DDM-P 900
Shared modules: GPSAM, GPxOIM, iCEM/iCEM-2/xCEM/eCEM,
iCCM/iCCM-2/xCCM

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 5-9
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD hardware presentation 9311 Macro V2 OD hardware presentation

....................................................................................................................................................................................................................................
9311 Macro V2 OD 2100/850 hardware presentation
The 9311 Macro V2 OD 2100/850 hardware is similar to the 9311 Macro V2 OD 2100
hardware, with dedicated (bandwidth-specific) and shared modules:
Dedicated modules:
For 2100 MHz: TRM/iTRM/xTRM 2100 + MCPA/MCPA-2/MCPA-3/MCPA
60W 2100 + DDM/DDM-2 2100
For 850 MHz: TRM/iTRM/xTRM 850 + MCPA/MCPA 60W 850 + DDM 850
Shared modules: GPSAM, GPxOIM, iCEM/iCEM-2/xCEM/eCEM,
iCCM/iCCM-2/xCCM

....................................................................................................................................................................................................................................
5-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
6 Checking the door alarm
6

Overview
Purpose
This part describes how to check the door alarm.

Contents

Checking the door alarm 6-2

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 6-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Checking the door alarm Checking the door alarm

....................................................................................................................................................................................................................................

Checking the door alarm


Purpose
The purpose of this procedure is to check the door intrusion alarm that is generated when
the Node B doors are opened.

Intervention time
Two minutes

Tools required
None
Important! This procedure requires to be in contact with the OMC administrator.
Important! For outdoor models, do not forget to ask the site manager for the Node B
key.

Procedure
...................................................................................................................................................................................................

1 Contact the OMC administrator to check that the door alarm is OFF.
...................................................................................................................................................................................................

2 Open the Node B door(s) to activate the door alarm.


...................................................................................................................................................................................................

3 An alarm must be observed at the OMC. Request confirmation from the OMC
administrator.
...................................................................................................................................................................................................

4 Close the Node B door(s).


...................................................................................................................................................................................................

5 Check with the OMC administrator that the door alarm is OFF.
E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
7 7311 Macro V2 OD power
9
down and power up
procedures

Overview
Purpose
This part describes how to power down and power up the 9311 Macro V2 OD cabinets.

Contents

Powering down a 9311 Macro V2 OD 7-2


Powering up a 9311 Macro V2 OD 7-4

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 7-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD power down and power up procedures Powering down a 9311 Macro V2 OD

....................................................................................................................................................................................................................................

Powering down a 9311 Macro V2 OD


Purpose
Perform the following procedure to power down a 9311 Macro V2 OD.

Preliminary operations
Make sure the state of the btsSiteManager object is "locked". For more information about
the OMC, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.
Important! Do not forget to ask the site manager for the Node B key.
Important! If an AC power down is required, notify the site manager then locate the
ac power supply on the customer site. Disconnect and lock out the AC main power
supply before servicing the equipment.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Switch OFF the four DDU circuit breakers in the following order:
DIGITAL/RICO/USER ICO
RF0 and RF1
ECU
Note: To locate DDU circuit breakers, see legend 8 in Figure 5-3, 9311 Macro V2
OD 2100 cabinet layout (p. 5-5)
...................................................................................................................................................................................................

3 Switch OFF the battery circuit breaker.


Note: To locate the battery circuit breaker, see legend 10 in Figure 5-3, 9311 Macro
V2 OD 2100 cabinet layout (p. 5-5)
...................................................................................................................................................................................................

4 Switch OFF the three ADU circuit breakers.


....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD power down and power up procedures Powering down a 9311 Macro V2 OD

....................................................................................................................................................................................................................................
Note: To locate ADU circuit breakers, see legend 5 in Figure 5-3, 9311 Macro V2
OD 2100 cabinet layout (p. 5-5)
...................................................................................................................................................................................................

5 At the customer AC power supply, switch OFF the cabinet circuit breaker.
...................................................................................................................................................................................................

6 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 7-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD power down and power up procedures Powering up a 9311 Macro V2 OD

....................................................................................................................................................................................................................................

Powering up a 9311 Macro V2 OD


Purpose
The procedure below describes how to power up a 9311 Macro V2 OD when it is
completely powered off.

Tools required
Local Installation Terminal (TIL)

Preliminary operations
Open the Node B doors and check the following:
The three ADU circuit breakers are switched OFF.
See legend 5 in Figure 5-3, 9311 Macro V2 OD 2100 cabinet layout (p. 5-5).
The four DDU circuit breakers are switched OFF.
See legend 8 in Figure 5-3, 9311 Macro V2 OD 2100 cabinet layout (p. 5-5).
The battery circuit breaker below the UCPS is switched OFF.
See legend 10 in Figure 5-3, 9311 Macro V2 OD 2100 cabinet layout (p. 5-5).
Important! This procedure requires to be in contact with the OMC administrator.
Important! Do not forget to ask the site manager for the Node B key.
Important! On the customer site, locate the AC power supply and notify the site
manager of the Node B start up.

Procedure
...................................................................................................................................................................................................

1 At the customer AC power supply, switch ON the circuit breaker.


...................................................................................................................................................................................................

2 Switch ON the three circuit breakers of the ADU.


...................................................................................................................................................................................................

3 Check that the green LED on each rectifier front face is lit, as well as the green LED on
the CCU.
...................................................................................................................................................................................................

4 On the DDU, switch ON the ECU circuit breaker.


...................................................................................................................................................................................................

5 Check that the fans are starting up.

....................................................................................................................................................................................................................................
7-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD power down and power up procedures Powering up a 9311 Macro V2 OD

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 In the upper compartment of the cabinet, check that the LEDs of the ECU control module
are lit.
Note: If the temperature is around freezing point or below, close the doors to warm up
the Node B.
...................................................................................................................................................................................................

7 On the DDU, switch ON the RF0 and RF1 circuit breakers.


...................................................................................................................................................................................................

8 Check that the green LED on each MCPA/SCPA module is lit.


...................................................................................................................................................................................................

9 On the DDU, switch ON the DIGITAL/RICO/USER ICO circuit breaker.


...................................................................................................................................................................................................

10 Check that the green LEDs on the CCM, GPSAM, and DDM modules are lit.
...................................................................................................................................................................................................

11 If battery back-up is used, and only if the green LED on the CCU is lit, switch ON the
battery circuit breaker below the UCPS.
...................................................................................................................................................................................................

12 Check on the TIL and with the OMC administrator that the Node B is operational.
...................................................................................................................................................................................................

13 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 7-5
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD power down and power up procedures Powering up a 9311 Macro V2 OD

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
7-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
8 8311 Macro V2 OD
9
corrective maintenance
procedures

Overview
Purpose
This part contains the replacement procedures applicable to the 9311 Macro V2 OD.

Contents

Replacing the digital shelf equipment 8-3


Replacing the Channel Element Module (CEM) 8-4
Replacing the Core Controller Module (CCM) 8-13
Replacing the GPS interface and Alarm Module (GPSAM) 8-23
Replacing the TRansceiver Module (TRM) 8-27
Replacing the GPxOIM 8-35
Replacing the C2OIM 8-40
Replacing the digital backplane of the 9311 Macro V2 OD 8-45
Replacing the optional xCCM radio interface Board (xCOB) 8-50
Replacing the RF block equipment 8-55
Replacing the Dual Duplexer Module (DDM) 8-56
Replacing the Multi-Carrier Power Amplifier module (MCPA) or Single-Carrier 8-64
Power Amplifier module (SCPA)
Replacing the Tx Splitter 8-76
Replacing a TRDU 8-80
Replacing the cooling system equipment 8-87
Replacing the air filter 8-88
Replacing the ECU control board 8-91
Replacing a fan 8-95

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Overview

....................................................................................................................................................................................................................................

Replacing the ECU ASSY S180 8-99


Replacing the power system equipment 8-102
Replacing the ADU module 8-103
Replacing the Cabinet Control Unit (CCU) module 8-107
Replacing the UCPS rectifiers 8-110
Replacing the rectifier rack and DDU 8-112
Replacing the batteries 8-117
Replacing the optional equipment 8-125
Replacing the Manufacturing Commissioning and Alarm (MCA) module 8-126
Replacing the alarm protection module 8-131
Replacing the double TMA module 8-134
Replacing the light TMA/AISG TMA module 8-139
Replacing the Power Amplifier InterCOnnection (PA ICO) module 8-145
Replacing the Radio Frequency InterCOnnection (RF ICO) module 8-149
Replacing the door gaskets 8-152
Replacing the foam gaskets 8-156
Replacing the door lock 8-160
Replacing the User ICO module 8-164

....................................................................................................................................................................................................................................
8-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Overview
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the digital shelf equipment

Overview
Purpose
This section presents the replacement procedures applicable to the digital shelf

Contents

Replacing the Channel Element Module (CEM) 8-4


Replacing the Core Controller Module (CCM) 8-13
Replacing the GPS interface and Alarm Module (GPSAM) 8-23
Replacing the TRansceiver Module (TRM) 8-27
Replacing the GPxOIM 8-35
Replacing the C2OIM 8-40
Replacing the digital backplane of the 9311 Macro V2 OD 8-45
Replacing the optional xCCM radio interface Board (xCOB) 8-50

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the Channel Element Module (CEM)


Purpose
Carry out the following procedure to replace the CEM.
Note: In the following procedure, the generic term CEM is used for
iCEM/iCEM-2/xCEM/eCEM.

Intervention time
Ten minutes

Tools required
Screwdriver
Local Installation Terminal (TIL)

....................................................................................................................................................................................................................................
8-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-1 iCEM 64 front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-5
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-2 iCEM-2 64 front panel

....................................................................................................................................................................................................................................
8-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-3 iCEM 128 front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-7
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-4 iCEM-2 128 front panel

....................................................................................................................................................................................................................................
8-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-5 xCEM front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-9
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-6 eCEM front panel

....................................................................................................................................................................................................................................
8-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
We recommend wearing an antistatic bracelet connected to ground via a protective
resistance to avoid damaging circuits when handling printed circuits.
Electronic boards must be stored in antistatic envelopes or inside packages both during
transportation and storage.
Important! Notify the OMC administrator in case of service outage or reduction.
Important! If the defective CEM is configured in HSDPA mode, the procedure to
replace it may trigger an alarm "NO HSDPA HARDWARE RECOVERY
INFORMATION" on the OMC-R (RNC side). For information on how to recover an
HSDPA capability, refer to Alcatel-Lucent 9300 W-CDMA Product Family - RNC and
MSS POC Alarms Reference, NN-20500-024.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Locate the faulty CEM in the digital shelf: its red triangular LED is lit.
...................................................................................................................................................................................................

3 Ask the OMC administrator to lock the faulty cem object at the OMC (through Set
Administrative State). For more information, please refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, NN-20500-032.
...................................................................................................................................................................................................

4 Loosen the two CEM front panel screws (2).


...................................................................................................................................................................................................

5 Remove the defective CEM using the front panel handle (1).
...................................................................................................................................................................................................

6 Check the release of the new CEM.


...................................................................................................................................................................................................

7 Insert the new CEM into the digital shelf, in the same slot as the defective CEM.
...................................................................................................................................................................................................

8 Tighten the two CEM front panel screws.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-11
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Channel Element Module (CEM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

9 Ask the OMC administrator to unlock the cem object previously locked on step 3.
...................................................................................................................................................................................................

10 Note: If the new CEM module requires a manual upgrade from the TIL, and if it is
used without being upgraded, it will run out of service.
Depending on the spare release and the OAM release, an intermediary manual upgrade
through the TIL might be necessary (see table below). For more information on how to
upgrade manually a CEM, refer to Alcatel-Lucent 9100 and 93xx Node B -
Commissioning and Fault Management User Manual: TIL, NN-20500-019.

Spare release Intermediary Upgrade Automatic Upgrade


OAM V2 OAM V3
UMTS1.2b UMTS2.0d UMTS3.1a
UMTS2.0e
UMTS2.0a UMTS2.1 UMTS3.1a
UMTS2.0b
UMTS2.0c
UMTS2.0d - -

The second upgrade is done automatically by the OMC-B.


Note: From UA05.1 and OAM V3, the upgrade is done automatically:
By the OAM, in case of a unique CEM (service outage)
By the closest CEM, in case of multiple CEMs (service reduction)
...................................................................................................................................................................................................

11 Check the state of the LEDs:


Result: Red triangular LED OFF, green rectangular LED ON
...................................................................................................................................................................................................

12 Check on the TIL and with the OMC administrator that the Node B is operational.
...................................................................................................................................................................................................

13 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the Core Controller Module (CCM)


Purpose
Carry out the following procedure to replace the CCM.
Note: In the following procedure, the generic term CCM is used for
CCM/iCCM/iCCM-2/xCCM.

Intervention time
Ten minutes

Tools required
Screwdriver
Extraction handle (3JR08430AA)
Local Installation Terminal (TIL)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-13
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-7 CCM front panel

....................................................................................................................................................................................................................................
8-14 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-8 iCCM front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-15
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-9 iCCM-2 front panel

....................................................................................................................................................................................................................................
8-16 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-10 xCCM front panel in configuration xCCM-4E1

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-17
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-11 xCCM front panel in configuration xCCM-GE

....................................................................................................................................................................................................................................
8-18 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! Notify the OMC administrator in case of service outage or reduction.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Ask the OMC administrator to lock all objects (through Set Administrative State)
associated with Remote Radio devices connected to this faulty CCM. For more
information, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

3 Power down the 9311 Macro V2 OD.


...................................................................................................................................................................................................

4 Case 1: On the CCM/iCCM/iCCM-2 front panel, disconnect the E1/T1 connector (PCM
link).
or
Case 2: On the xCCM (in the configuration xCCM-4E1) front panel, disconnect the two
E1/T1 connectors (PCM and MDA links) and the Ethernet connector (port1) if hybrid Iub
is implemented.
or
Case 3: On the xCCM (in the configuration xCCM-GE) front panel, disconnect the Giga
Ethernet connector (MDA links).
...................................................................................................................................................................................................

5 Case 1: If you replace a CCM, loosen the two CCM module screws. (See legend 2 on
Figure 8-7, CCM front panel (p. 8-14).)
or
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-19
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Case 2: If you replace an iCCM/iCCM-2/xCCM, only its board needs to be replaced. In
that case, loosen the two iCCM/iCCM-2/xCCM board screws. (See legend 2 on Figure
8-9, iCCM-2 front panel (p. 8-16) or legend 10 on Figure 8-10, xCCM front panel in
configuration xCCM-4E1 (p. 8-17).)
...................................................................................................................................................................................................

6 Case 1: Remove the defective CCM using the front panel handle.
or
Case 2: Remove the defective iCCM/iCCM-2/xCCM using the extraction handle. (See
Tools required (p. 8-13).)
...................................................................................................................................................................................................

7 Case 1: If you replace a CCM by another CCM, insert the new CCM into the digital
shelf, in the same slot as the defective CCM.
or
Case 2: If you replace a CCM by an iCCM/iCCM-2, insert the new iCCM/iCCM-2
module (board + filler) into the digital shelf, in the same slot as the defective CCM.
or
Case 3: If you replace an iCCM/iCCM-2/xCCM by an iCCM/iCCM-2/xCCM, insert the
new iCCM/iCCM-2/xCCM board into the digital shelf, in the same dual slot as the
defective iCCM/iCCM-2/xCCM board.
...................................................................................................................................................................................................

8 Depending on the case, tighten the two CCM front module screws or the two
iCCM/iCCM-2/xCCM front board screws.
...................................................................................................................................................................................................

9 Power up the 9311 Macro V2 OD.


...................................................................................................................................................................................................

10 Check the state of the LEDs on the CCM:


Result: Red triangular LED OFF, green rectangular LED ON
...................................................................................................................................................................................................

11 Note: If the new CCM module requires a manual upgrade from the TIL, and if it is
used without being upgraded, it will run out of service.
Depending on the spare release and the OAM software release, an intermediary upgrade
through the TIL might be necessary.

....................................................................................................................................................................................................................................
8-20 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Upgrade the software, if necessary, according to the table below. For more information on
how to upgrade the CCM module through the TIL, refer to Alcatel-Lucent 9100 and 93xx
Node B - Commissioning and Fault Management User Manual: TIL, NN-20500-019.
The second upgrade is done by the OMC-B, automatically.

Spare Release Intermediary Upgrade Automatic Upgrade


OAM V2 OAM V3
UMTS1.2b UMTS2.0d UMTS3.1a
UMTS2.0e
UMTS2.0a UMTS2.1 UMTS3.1a
UMTS2.0b
UMTS2.0c
UMTS2.0d - -

...................................................................................................................................................................................................

12 Case 1: On the CCM/iCCM/iCCM-2 front panel, connect the E1/T1 connector.


or
Case 2: On the xCCM (in the configuration xCCM-4E1) front panel, connect the two
E1/T1 connectors (PCM and MDA links) and the Ethernet connector (port1) if hybrid Iub
is implemented.
or
Case 3: On the xCCM (in the configuration xCCM-GE) front panel, connect the Giga
Ethernet connector (MDA links).
Note: The xCCM requires a specific cabling kit.
...................................................................................................................................................................................................

13 Ask the OMC administrator to unlock the objects previously locked on step 2.
...................................................................................................................................................................................................

14 Check the MCA module with the TIL. For more information, refer to the TIL main
window and the GPSAM module in Alcatel-Lucent 9100 and 93xx Node B -
Commissioning and Fault Management User Manual: TIL, NN-20500-019.

The MCA module is correct. The MS LED then


is green.
Yes Go to Step 15.
No Replace the MCA module.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-21
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Core Controller Module (CCM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

15 Check the state of the LEDs:


Result: Green PCM LEDs ON. The display must indicate the PCM synchronization.
...................................................................................................................................................................................................

16 Check on the TIL and with the OMC administrator that the Node B is operational.
...................................................................................................................................................................................................

17 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-22 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPS interface and Alarm Module (GPSAM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the GPS interface and Alarm Module (GPSAM)


Purpose
Carry out the following procedure to replace the GPSAM of the 9311 Macro V2 OD.

Intervention time
Ten minutes

Tools required
Screwdriver

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-23
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPS interface and Alarm Module (GPSAM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-12 GPSAM front panel

....................................................................................................................................................................................................................................
8-24 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPS interface and Alarm Module (GPSAM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the faulty GPSAM on the right-hand side of the digital shelf.
...................................................................................................................................................................................................

3 Important! Notify the OMC administrator in case of service outage or reduction.


To power down the digital shelf, switch OFF the Digital circuit breaker on the DC power
system shelf.
...................................................................................................................................................................................................

4 Disconnect the digital cable in front of the GPSAM.


...................................................................................................................................................................................................

5 Loosen the two GPSAM front panel screws (2).


...................................................................................................................................................................................................

6 Remove the defective GPSAM using the front panel handle (1).
...................................................................................................................................................................................................

7 Insert the new GPSAM into the digital shelf.


...................................................................................................................................................................................................

8 Reconnect the digital cable to the front of the GPSAM, in the "Internal bus" slot.
...................................................................................................................................................................................................

9 Select the "Base" choice for the three-position switch.


...................................................................................................................................................................................................

10 Tighten the two GPSAM front panel screws.


...................................................................................................................................................................................................

11 To power up the digital shelf, switch ON the Digital circuit breaker on the DC power
system shelf.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-25
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPS interface and Alarm Module (GPSAM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Result: The GPSAM will go through a power-up sequence.
...................................................................................................................................................................................................

12 Check the state of the LEDs. They should go on, then take the following states:
Result: Red triangular LED OFF, green rectangular LED ON
...................................................................................................................................................................................................

13 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-26 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the TRansceiver Module (TRM)


Purpose
Carry out the following procedure to replace a TRM.
Note: In the following procedure, the generic term TRM is used for
TRM/iTRM/xTRM/xTRM-2.

Intervention time
Ten minutes

Tools required
Screwdriver
SMA torque wrench
Local Installation Terminal (TIL)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-27
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-13 TRM front panel

....................................................................................................................................................................................................................................
8-28 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-14 iTRM front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-29
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-15 xTRM front panel

....................................................................................................................................................................................................................................
8-30 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-16 xTRM-2 front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-31
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
We recommend wearing an antistatic bracelet connected to ground via a protective
resistance to avoid damaging circuits when handling printed circuits.
Electronic boards must be stored in antistatic envelopes or inside packages both during
transportation and storage.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.
Important! Precautions to be observed when plugging/unplugging the TRM Rx
connector
The TRM Rx connector (coaxpack) is very sensitive in the Node B design,
contributing to the global quality reception. It has therefore to be treated with care
when removed or replaced for maintenance purpose.
Ensure at any time its correct alignment with guides, the lock system being placed
on the left.
Ensure the lock system operates properly.
Do not apply force when inserting it.
Ensure a perfect straight angle with the TRM front panel.
If tie-raps are applied to secure the cable within the cabinet, ensure they are not
putting any constraint to that connector.
Important! The tightening torque of the front panel screws must be 0.25 N.m (0.2375
N.m to 0.2625 N.m).
The SMA tightening torque must be 0.8 N.m to 1.2 N.m.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Locate the faulty TRM in the digital shelf: its red triangular LED is lit.
...................................................................................................................................................................................................

3 Ask the OMC administrator to lock the faulty trm object at the OMC (by Set
Administrative State). For more information, please refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, NN-20500-032.
....................................................................................................................................................................................................................................
8-32 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Loosen the two TRM front panel screws (2).


...................................................................................................................................................................................................

5 Unplug the faulty TRM.


...................................................................................................................................................................................................

6 Disconnect the following cables from the TRM front panel:


RF out port, using the SMA wrench
Digital cable from the Interco
RF cable
For xTRM, the BBPD feedback cables from the MCPA 60W-B (if used)
...................................................................................................................................................................................................

7 Remove the defective TRM using the front panel handle (1).
...................................................................................................................................................................................................

8 Check the release of the new TRM.


...................................................................................................................................................................................................

9 Insert the new TRM into the digital shelf.


...................................................................................................................................................................................................

10 Reconnect the following cables:


RF out port, using the SMA torque wrench
RF cable
Digital cable
For xTRM, the BBPD feedback cables to the MCPA 60W-B (if used)
...................................................................................................................................................................................................

11 Tighten the two TRM front panel screws.


...................................................................................................................................................................................................

12 Connect the Digital cable to the Interco.


...................................................................................................................................................................................................

13 Note: If the new TRM module requires a manual upgrade at the TIL, and if it is used
without being upgraded, it will run out of service.
Depending on the spare release and on the OAM release, an intermediary upgrade might
be necessary through the TIL.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-33
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the TRansceiver Module (TRM)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Upgrade the software, if necessary according to the table below. For more information on
how to upgrade the TRM through the TIL, refer to Alcatel-Lucent 9100 and 93xx Node B
- Commissioning and Fault Management User Manual: TIL, NN-20500-019.
The second upgrade is done by the OMC-B automatically.

Spare release Intermediary Upgrade Automatic Upgrade


OAM V2 OAM V3
UMTS1.2b UMTS2.0d UMTS3.1a
UMTS2.0e
UMTS2.0a UMTS2.1 UMTS3.1a
UMTS2.0b
UMTS2.0c
UMTS2.0d - -

...................................................................................................................................................................................................

14 Check the RF Tx cabling representation. For more information, refer to Alcatel-Lucent


9100 and 93xx Node B - Commissioning and Fault Management User Manual: TIL,
NN-20500-019.
...................................................................................................................................................................................................

15 Ask the OMC administrator to unlock the trm object previously locked in step 3.
...................................................................................................................................................................................................

16 Check the state of the LEDs. They should go on, then take the following states.
Result: Red triangular LED OFF, green triangular LED ON
...................................................................................................................................................................................................

17 Check on the TIL and with the OMC administrator that the Node B is operational.
...................................................................................................................................................................................................

18 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-34 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPxOIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the GPxOIM


Purpose
Carry out the following procedure to replace the GPxOIM.

Intervention time
Ten minutes

Tools required
Screwdriver
Extraction handle (P/N: P0850747)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-35
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPxOIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-17 GPxOIM front panel (with C2OIM inserted)

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.

....................................................................................................................................................................................................................................
8-36 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPxOIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the faulty GPxOIM on the right-hand side of the digital shelf: its red triangular
LED is lit. (See Figure 5-3, 9311 Macro V2 OD 2100 cabinet layout (p. 5-5))
...................................................................................................................................................................................................

3 NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Ask the OMC administrator to lock (by Set Administrative State) all objects associated
with the RRH modules connected to the faulty GPxOIM. For more information, refer to
Alcatel-Lucent 9353 Wireless Management System - User Guide, NN-20500-032.
...................................................................................................................................................................................................

4 Disconnect the two optical fibers from the C2OIM front panel.
...................................................................................................................................................................................................

5 Disconnect the digital cable ("Internal Bus" connector) from the GPxOIM front panel.
...................................................................................................................................................................................................

6 Unscrew the two C2OIM front panel screws.


...................................................................................................................................................................................................

7 Extract the C2OIM from the GPxOIM mechanics using the extraction handle.
...................................................................................................................................................................................................

8 Unscrew the two front panel screws located at the top and at the bottom of the 50-mm
GPxOIM mechanics (1).
...................................................................................................................................................................................................

9 Remove the defective GPxOIM.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-37
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPxOIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

10 Insert the new GPxOIM into the digital shelf.


...................................................................................................................................................................................................

11 Tighten the two GPxOIM front panel screws.


...................................................................................................................................................................................................

12 Reconnect the digital cable on the GPxOIM front panel.


...................................................................................................................................................................................................

13 Select the "Base" position for the three-position switch on the GPxOIM front panel.
...................................................................................................................................................................................................

14 Reinsert the C2OIM into the GPxOIM mechanics.


...................................................................................................................................................................................................

15 Tighten the two C2OIM front panel screws.


...................................................................................................................................................................................................

16 Important! In case of a C2OIM-GM module, respect the color code (blue LC


connector above/red LC connector below) when reconnecting the optical fibers on the
C2OIM front panel.
Reconnect the two optical fibers on the C2OIM front panel.

Figure 8-18 Color code for Multi-Mode SFP transceivers

...................................................................................................................................................................................................

17 Ask the OMC administrator to unlock the objects previously locked on step 3.
....................................................................................................................................................................................................................................
8-38 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the GPxOIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

18 Check the state of the LEDs. They should turn on, then take the following states:
On the GPxOIM, red triangular LED OFF and green rectangular LED ON
On the C2OIM, Tx Act and Rx Act green LEDs ON
...................................................................................................................................................................................................

19 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

20 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-39
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the C2OIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the C2OIM


Purpose
Carry out the following procedure to replace a C2OIM.

Intervention time
Five minutes

Tools required
Screwdriver
Extraction handle (P/N: P0850747)

....................................................................................................................................................................................................................................
8-40 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the C2OIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-19 C2OIM-GM front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-41
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the C2OIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-20 C2OIM-GS front panel

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.

....................................................................................................................................................................................................................................
8-42 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the C2OIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the faulty C2OIM on the right-hand side of the digital shelf: its red triangular LED
is lit. (See Figure 5-3, 9311 Macro V2 OD 2100 cabinet layout (p. 5-5))
...................................................................................................................................................................................................

3 NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Ask the OMC administrator to lock all optical link objects (by Set Administrative State).
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

4 Disconnect the two optical fibers from the C2OIM front panel.
...................................................................................................................................................................................................

5 Unscrew the two C2OIM front panel screws (1).


...................................................................................................................................................................................................

6 Extract the defective C2OIM from the GPxOIM mechanics using the extraction handle.
...................................................................................................................................................................................................

7 Insert the new C2OIM into the GPxOIM mechanics.


...................................................................................................................................................................................................

8 Tighten the two C2OIM front panel screws.


...................................................................................................................................................................................................

9 Important! In case of a C2OIM-GM module, respect the color code (blue LC


connector above/red LC connector below) when reconnecting the optical fibers on the
C2OIM front panel.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-43
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the C2OIM
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Reconnect the two optical fibers on the C2OIM front panel.

Figure 8-21 Color code for Multi-Mode SFP transceivers

...................................................................................................................................................................................................

10 Ask the OMC administrator to unlock all optical link objects previously locked on step 3.
...................................................................................................................................................................................................

11 Check the state of the LEDs on the C2OIM front panel. They should turn on, then take
the following state:
Result: Tx Act and Rx Act green LEDs ON
...................................................................................................................................................................................................

12 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

13 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-44 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the digital backplane of the 9311 Macro V2 OD
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the digital backplane of the 9311 Macro V2 OD


Purpose
Carry out the following procedure to replace the digital backplane of the 9311 Macro V2
OD.

Intervention time
60 minutes

Tools required
Flat screwdriver
Cross-head screwdriver
Screwdriver for bolts (specific for 4-40 screws)
Wrench

NOTICE
ESD hazard
We recommend wearing an antistatic bracelet connected to ground via a protective
resistance to avoid damaging circuits when handling printed circuits.
Electronic boards must be stored in antistatic envelopes or inside packages both during
transportation and storage.
Important! Notify the OMC administrator in case of service outage or reduction.
Important! The tightening torque of the 4-40 UNC bolts must be 46 N.cm.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Power down the Node B. (See Powering down a 9311 Macro V2 OD (p. 7-2))
...................................................................................................................................................................................................

3 Important! The connectors for the Coaxpack must be unplugged carefully.


Disconnect all the connectors on the front panel of the digital modules:
Manually, for the Coaxpack (4) and RJ45 (3) connectors.
With the wrench, for the SMA connectors (2).
With the bolts screwdriver, for the UNC bolts of the Sub D connectors (5).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-45
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the digital backplane of the 9311 Macro V2 OD
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-22 Digital rack front panel

...................................................................................................................................................................................................

4 Unscrew the two screws (1) per module for each digital module and filler.
...................................................................................................................................................................................................

5 Remove all digital modules and fillers.


...................................................................................................................................................................................................

6 Disconnect the DC power cable.

....................................................................................................................................................................................................................................
8-46 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the digital backplane of the 9311 Macro V2 OD
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-23 DC connector

...................................................................................................................................................................................................

7 Unscrew the eight fixing screws of the digital backplane.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-47
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the digital backplane of the 9311 Macro V2 OD
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-24 Fixing screws of the digital backplane

...................................................................................................................................................................................................

8 Remove the digital backplane.


...................................................................................................................................................................................................

9 Insert the new digital backplane.


...................................................................................................................................................................................................

10 Tighten the eight fixing screws of the new digital backplane.


Note: For tightening torque, see Tools required (p. 8-45)
...................................................................................................................................................................................................

11 Reconnect the DC power cable.


...................................................................................................................................................................................................

12 Insert all the digital modules and fillers.


...................................................................................................................................................................................................

13 Tighten the two captive screws per digital module and filler (see legend 1 in Figure 8-22,
Digital rack front panel (p. 8-46)).

....................................................................................................................................................................................................................................
8-48 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the digital backplane of the 9311 Macro V2 OD
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

14 Important! The connectors for the Coaxpack must be unplugged carefully.


Reconnect the Coaxpack (4) and RJ45 (3) connectors on the front panel of the digital
modules.
...................................................................................................................................................................................................

15 Reconnect the SMA connectors (2) and the UNC bolts of the Sub D connectors (5).
Note: For tightening torque, see Tools required (p. 8-45)
...................................................................................................................................................................................................

16 Power up the Node B. (See Powering up a 9311 Macro V2 OD (p. 7-4))


...................................................................................................................................................................................................

17 Check with the OMC administrator that all alarms are OK.
...................................................................................................................................................................................................

18 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-49
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the optional xCCM radio interface Board (xCOB)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the optional xCCM radio interface Board (xCOB)


Intervention time
Ten minutes

Tools required
To complete this procedure you will require:
Screwdriver
Extraction handle (3JR08430AA)
Local Installation Terminal (TIL)

....................................................................................................................................................................................................................................
8-50 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the optional xCCM radio interface Board (xCOB)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

Figure 8-25 xCOB and xCCM modules

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-51
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the optional xCCM radio interface Board (xCOB)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
8-52 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the optional xCCM radio interface Board (xCOB)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Figure 8-26 xCOB front panel

NOTICE
Service-disruption hazard
This procedure can cause a service outage or reduction.
Notify the OMC administrator in case of service outage or reduction.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-53
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the optional xCCM radio interface Board (xCOB)
Replacing the digital shelf equipment
....................................................................................................................................................................................................................................
Procedure
Carry out the following procedure to replace XCOB module
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Locate the faulty XCOB in the digital shelf: its red triangular LED is lit.
...................................................................................................................................................................................................

3 On the XCOB front panel, disconnect the six CPRI bi-directional optical or electrical
links.
...................................................................................................................................................................................................

4 Loosen the two XCOB front panel screws.


...................................................................................................................................................................................................

5 Remove the defective XCOB using the front panel handle.


...................................................................................................................................................................................................

6 Insert the new XCOB into the mini backplane of XCCM module
...................................................................................................................................................................................................

7 Tighten the two XCOB front panel screws.


...................................................................................................................................................................................................

8 On the XCOB front panel, connect the six CPRI bi-directional optical or electrical links.
...................................................................................................................................................................................................

9 Check the state of the LEDs on the XCOB


Result: Red triangular LED OFF, green rectangular LED ON
...................................................................................................................................................................................................

10 Check on the TIL and with the OMC administrator that the Node B is operational.
...................................................................................................................................................................................................

11 Close the Node B door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-54 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Overview
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Replacing the RF block equipment

Overview
Purpose
This section presents the replacement procedures applicable to the RF block.

Contents

Replacing the Dual Duplexer Module (DDM) 8-56


Replacing the Multi-Carrier Power Amplifier module (MCPA) or Single-Carrier 8-64
Power Amplifier module (SCPA)
Replacing the Tx Splitter 8-76
Replacing a TRDU 8-80

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-55
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Replacing the Dual Duplexer Module (DDM)


Purpose
The DDM is hot-swappable, therefore no power-down is required.
Carry out the following procedure to replace the DDM.
Note: In the following procedure, the generic term DDM is used for
DDM/DDM-2/DDM-E 900/DDM-P 900/AISG DDM.

Intervention time
Ten minutes

Tools required
Extraction handle (3JR08430AA)
Flat screwdriver
SMA torque wrench
7/16 torque wrench
N torque wrench
Local Installation Terminal (TIL)

....................................................................................................................................................................................................................................
8-56 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Figure 8-27 DDM front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-57
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Figure 8-28 DDM-2/DDM-E 900/DDM-P 900 front panel

Figure 8-29 AISG DDM front panel

....................................................................................................................................................................................................................................
8-58 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Important!
The tightening torque of the front panel screws must be 0.25 N.m (0.2375 N.m to
0.2625 N.m).
The SMA tightening torque must be 0.8 N.m to 1.2 N.m.
The 7/16 tightening torque must be 25 N.m (24 N.m to 27 N.m).
The N tightening torque must be 1.7 N.m (1.6 N.m to 1.8 N.m).

CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
Turn off and lockout the transmit power before working on the antenna system.
If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna stand-off distances.
Do not use auxiliary antennas.
Consult with the Antenna exposure statements before begining work.

NOTICE
ESD hazard
We recommend wearing an antistatic bracelet connected to ground via a protective
resistance to avoid damaging circuits when handling printed circuits.
Electronic boards must be stored in antistatic envelopes or inside packages both during
transportation and storage.
Important! This procedure requires a service reduction from the Node B estimated at
ten minutes. Notify the OMC administrator.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the faulty DDM in the DDM shelf: its red triangular LED is lit.
...................................................................................................................................................................................................

3 Ask the OMC administrator to lock the ddm object (by Set Administrative State). It is
also recommended to lock the mcpa object of the associated MCPA/SCPA module. For
more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-59
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Locate the following cables from the DDM:


Power/data cables
Transmitter cables
Rx cables
Antenna cables
AISG cable for AISG DDM
...................................................................................................................................................................................................

5 Disconnect the following cables and connectors from the DDM front panel:
The power cable (connection with the Interco module)
For AISG DDM, the AISG cable (connection with CCU)
The two antenna cables using the 7/16 wrench (connection with RF bulkheads)
The Rx cables using the SMA wrench (connection with the TRM/iTRM module)
The transmitter cable using the N wrench (connection with the MCPA/SCPA module)
...................................................................................................................................................................................................

6 Untighten the four securing screws on the DDM front panel.


...................................................................................................................................................................................................

7 Extract the defective DDM with the extraction handle and remove it.
...................................................................................................................................................................................................

8 Insert the new DDM.


...................................................................................................................................................................................................

9 Remove the 50-ohm loads from the Rx ports that are to be plugged.
These 50-ohm loads are present on the Rx ports labelled Rx1, Rx2, Rx3 on the DDM
front panel.
...................................................................................................................................................................................................

10 Tighten the four securing screws.


...................................................................................................................................................................................................

11 Locate the following connectors on the DDM front panel:


Power/data connector
Rx connectors
Antenna connectors
Transmitter connectors
AISG connector for AISG DDM

....................................................................................................................................................................................................................................
8-60 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

12 Reconnect the power/data cable to the new DDM.


...................................................................................................................................................................................................

13 Reconnect the following cables and connectors to the DDM front panel:
The two antenna cables using the 7/16 wrench
The Rx cables using the SMA wrench
The transmitter cable using the N wrench
The AISG cable for AISG DDM
Important! Pay attention to cable torsion and bend radius for the two antenna cables
(between DDM and Bulkhead).
The following figure gives the bad example for the assembly of antenna cables. The curve
may damage the cable

Figure 8-30 A bad assembly of antenna cables

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-61
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................
The following figure gives a correct example for the assembly of antenna cables

Figure 8-31 A correct assembly of antenna cables

Note: For tightening torques, see Caution table in Tools required (p. 8-56) section.
...................................................................................................................................................................................................

14 Reset the Node B by using the TIL tool or from the OMC. For more information, refer to
the following documents:
Alcatel-Lucent 9100 and 93xx Node B - Commissioning and Fault Management User
Manual: TIL, NN-20500-019
Alcatel-Lucent 9353 Wireless Management System - User Guide, NN-20500-032
...................................................................................................................................................................................................

15 Ask the OMC administrator to unlock the ddm and mcpa objects previously locked on
step 3. For more information, refer to Alcatel-Lucent 9353 Wireless Management System -
User Guide, NN-20500-032.
...................................................................................................................................................................................................

16 Check the state of the DDM LEDs. They should go on then take the following states:
Result: Red triangular LED OFF, green rectangular LED ON
...................................................................................................................................................................................................

17 Check the state of the TMA LED in front of the DDM.


...................................................................................................................................................................................................

18 Check on the TIL and with the OMC administrator that the Node B is operational.

....................................................................................................................................................................................................................................
8-62 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Dual Duplexer Module (DDM)
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

19 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-63
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................

Replacing the Multi-Carrier Power Amplifier module (MCPA) or


Single-Carrier Power Amplifier module (SCPA)
Purpose
Carry out the following procedure to replace an MCPA/SCPA module.
Note: In the following procedure, the generic term MCPA is used for MCPA
850/MCPA 2100/MCPA-2 2100/MCPA-3 2100/MCPA 60W 850/MCPA 60W 2100,
and SCPA is used for SCPA 900 55W.

Intervention time
15 minutes

Tools required
SMA torque wrench
N torque wrench
Phillips and flat screwdrivers

....................................................................................................................................................................................................................................
8-64 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................

Figure 8-32 MCPA front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-65
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
Figure 8-33 MCPA 60W-A front panel

....................................................................................................................................................................................................................................
8-66 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
Figure 8-34 MCPA 60W-B front panel

Unlike the MCPA 60W-B module, the MCPA 60W-A module is not equipped with two
RF connectors for feedback links to xTRM (see FB1 and FB2 in Figure 8-34, MCPA
60W-B front panel (p. 8-67)).
For differences between MCPA 60W-A and MCPA 60W-B, refer to Alcatel-Lucent 9311
Macro V2 Node B Outdoor Technical Description, NN-20500-004.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-67
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................

Figure 8-35 SCPA 900 55W front panel

CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
Turn off and lockout the transmit power before working on the antenna system.
If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna stand-off distances.
Do not use auxiliary antennas.
Consult with the Antenna exposure statements before begining work.
....................................................................................................................................................................................................................................
8-68 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
We recommend wearing an antistatic bracelet connected to ground via a protective
resistance to avoid damaging circuits when handling printed circuits.
Electronic boards must be stored in antistatic envelopes or inside packages both during
transportation and storage.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.
Important!
The tightening torque of the front panel screws must be 0.25 N.m (0.2375 N.m to
0.2625 N.m).
The SMA tightening torque must be 0.8 N.m to 1.2 N.m.
The N tightening torque must be 1.7 N.m (1.6 N.m to 1.8 N.m).

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the faulty MCPA/SCPA module in the cabinet.


...................................................................................................................................................................................................

3 Important! Notify the OMC administrator in case of service outage or reduction.


Ask the OMC administrator to lock the mcpa object (by Set Administrative State). For
more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

4 Switch OFF "0" the MCPA/SCPA module.


Note: The switch is located on the MCPA/SCPA module front panel.
...................................................................................................................................................................................................

5 In front of the faulty MCPA/SCPA module, disconnect the following cables:


The digital cable connected to the "Data I/O" connector
The RF cable connected to the "RF IN" connector, using the SMA wrench
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-69
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
The N cable connected to the "Transmitter" connector, using the N wrench
For an MCPA 60W-B module only, the BBPD feedback cables connected to the "FB"
connectors
...................................................................................................................................................................................................

6 Important! Beware that if you do not disconnect the power cable at the
interconnection module, there is a risk of destroying the equipment, because of a
connected -48 V cable hanging down.
First, remove the power cable at the interconnection module (do not remove the data
cable). Then, in front of the faulty MCPA/SCPA module, disconnect the power cable that
is connected to the "Power IN" connector.
...................................................................................................................................................................................................

7 Untighten the four MCPA/SCPA module front panel screws (2) using the Phillips
screwdriver.
...................................................................................................................................................................................................

8 Remove the faulty MCPA/SCPA module using the front panel handle (1).
...................................................................................................................................................................................................

9 Insert the new MCPA/SCPA module.


...................................................................................................................................................................................................

10 Tighten the four MCPA/SCPA module front panel screws, using the Phillips screwdriver.
...................................................................................................................................................................................................

11 Check that the new MCPA/SCPA module is switched OFF.


...................................................................................................................................................................................................

12 Important! Before connecting the power cable to the MCPA/SCPA module connector
:
Check the correct side of the D-sub connector.
Make sure the small side of the MCPA/SCPA module connector is connected to
the small side of the MCPA/SCPA module cable connector.
Never connect the small side with the large side, otherwise there is a risk of
MCPA/SCPA module failure.
Notice that the MCPA/SCPA modules stand upside down in the 9311 Macro V2 OD
cabinet.
In front of the MCPA/SCPA module, connect the power cable to the "Power IN"
connector.

....................................................................................................................................................................................................................................
8-70 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

13 DANGER
Personnel protection
When connecting the power cable to the interconnection module, be careful not to touch
the interconnection module.
Connect the power cable to the interconnection module.
...................................................................................................................................................................................................

14 In front of the MCPA/SCPA module, connect the following cables:


The digital cable to the "Data I/O" connector
The RF cable to the "RF IN" connector, using the SMA wrench
The N cable to the "Transmitter" connector, using the N wrench
For an MCPA 60W-B module only, the BBPD feedback cables to the "FB" connectors
Note: For tightening torques, see Caution table in Tools required (p. 8-64).
...................................................................................................................................................................................................

15 Check the RF Tx cabling representation. For more information, refer to Alcatel-Lucent


9100 and 93xx Node B - Commissioning and Fault Management User Manual: TIL,
NN-20500-019.
...................................................................................................................................................................................................

16 Switch ON "1" the MCPA/SCPA module.


The MCPA/SCPA module is automatically unlocked.
...................................................................................................................................................................................................

17 <Optional> If the MCPA/SCPA module is not automatically unlocked, ask the OMC
administrator to unlock the mcpa object previously locked on step 3. For more
information, refer to Alcatel-Lucent 9353 Wireless Management System - User Guide,
NN-20500-032.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-71
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

18 Check the MCPA/SCPA LED if the Node B is connected and configured by the network:
The MCPA/SCPA LED is Green if it is configured to transmit
The MCPA/SCPA LED is Red as long as it is not configured to transmit

State of the LED then


Green Check the new FDDCell object at the OMC-B
through Set Administrative State. For more
information, refer to Alcatel-Lucent 9353
Wireless Management System - User Guide,
NN-20500-032. Close the Node B doors.
without resetting the Node B
Red If the MCPA/SCPA is configured to transmit,
call the operator at the OMC-B and check with
him any existing alarms. If a Downloading
Erroralarm exists at the OMC-B, refer to
MCPA Firmware conditionnal download after
MCPA replacement (p. 8-72) for detailed
information.

...................................................................................................................................................................................................

19 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

20 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

MCPA Firmware conditionnal download after MCPA replacement


After an MCPA replacement (as well as during Node B initialization), the Node B
downloads a new firmware for certain types of MCPA modules.
Cajun MCPA download
The concerned MCPA modules are all MCPA 2100 modules (PEC: NTUM30AA), from
D4, E4, 01, and 02 hardware releases of Cajun type MCPA modules.
The Cajun designation identifies the first generation of UMTS MCPA modules deployed.
From now on, the firmware of these MCPA modules is automatically aligned to the
required version.

....................................................................................................................................................................................................................................
8-72 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
Downloading error at the OMC-B
After an MCPA replacement, the firmware of the replacing MCPA is upgraded for the
mentioned MCPA types. Most of the time, this firmware download is successful, and
allows to upgrade the Cajun MCPA module that has just been inserted without resetting
the Node B. But in some rare cases, the download attempt may result in a Downloading
Error and a minor alarm reporting to the OMC-B, with the following status:
Cause: Downloading Error
Equipment Type: MCPA
Perceived Severity: minor
This alarm is minor since the MCPA continues to be operational in its not upgraded
version. The Downloading Error cause has four sub-causes, that are described in the
following table.

Table 8-1 Downloading error sub-causes

Downloading error Sub-cause value in Node B status Maintenance


sub-causes the "ManufInfo" action
field of the alarm
message
Corrupted flash 04 The downloaded The MCPA
MCPA has a replacement is not
corrupted flash urgent. The MCPA
memory. The should be replaced at
firmware cannot be the next visit on site,
upgraded. The MCPA in order to align this
remains operational site on the latest
on its unchanged MCPA performance.
firmware. The Node No other Node B
B remains reset should be
operational. attempted (to
download the MCPA
anew). This
recommendation
minimizes Node B
downtime.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-73
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................
Table 8-1 Downloading error sub-causes (continued)

Downloading error Sub-cause value in Node B status Maintenance


sub-causes the "ManufInfo" action
field of the alarm
message
Individual MCPA 05 Individual MCPA The network operator
download timeout download timeout has should attempt a
expired. Node B reset anew. If
this second attempt
Global MCPA 06 The timeout to does not succeed to
download timeout download the group download this
of MCPAs has MCPA, the Node B
expired. The Node B continues its
has identified that initialization
there is not enough sequence and
time left to attempt provides nominal
the download of this service, with the
MCPA. unchanged MCPA
firmware. The MCPA
Miscellaneous 03 Software issues should be replaced at
software causes the next visit on site
(not urgent).

The following flow diagram illustrates the global Cajun MCPA download process,
including the maintenance actions to be performed in case of a Downloading Error
alarm.

....................................................................................................................................................................................................................................
8-74 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Multi-Carrier Power Amplifier module (MCPA)
Replacing the RF block equipment or Single-Carrier Power Amplifier module (SCPA)
....................................................................................................................................................................................................................................

Figure 8-36 Cajun MCPA download - maintenance actions

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-75
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Tx Splitter
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Replacing the Tx Splitter


Purpose
Carry out the following procedure to replace the Tx Splitter.

Intervention time
Ten minutes

Tools required
N torque wrench
Phillips screwdriver
Flat screwdriver
Local Installation Terminal (TIL)

Figure 8-37 Tx Splitter front panel

....................................................................................................................................................................................................................................
8-76 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Tx Splitter
Replacing the RF block equipment
....................................................................................................................................................................................................................................

CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
Turn off and lockout the transmit power before working on the antenna system.
If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna stand-off distances.
Do not use auxiliary antennas.
Consult with the Antenna exposure statements before begining work.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important!
The N tightening torque must be 1.7 N.m (1.6 N.m to 1.8 N.m).
The tightening torque of the front panel screws must be 0.25 N.m (0.2375 N.m to
0.2625 N.m).
Important! This procedure leads to a service outage from the Node B estimated at ten
minutes. Notify the OMC administrator of a service outage.
Important! Respect bend radius of cables while tightening connectors.
Pay attention to cable torsion and bend radius during maintenance operations.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the faulty Tx Splitter in the MCPA shelf, its LED is OFF (1).
...................................................................................................................................................................................................

3 Note: Notify the OMC administrator of a service outage.


Ask the OMC administrator to lock the MCPA and DDM objects (by Set Administrative
State). For more information, refer to Alcatel-Lucent 9353 Management System - User
Guide, NN-20500-032.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-77
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Tx Splitter
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Disconnect the POWER/DATA cable.


...................................................................................................................................................................................................

5 Disconnect the following cables and connectors from the front panel of the Tx Splitter:
The three DDM cables (N connectors) using the N torque wrench
The MCPA module cable (N connector) using the N torque wrench
...................................................................................................................................................................................................

6 Undo the four securing screws on the front panel of the Tx Splitter (2).
...................................................................................................................................................................................................

7 Extract the faulty Tx Splitter with the handle and remove it.
...................................................................................................................................................................................................

8 Insert the new Tx Splitter into the Node B.


...................................................................................................................................................................................................

9 Tighten the four securing screws.


...................................................................................................................................................................................................

10 Reconnect the following cables and connectors to the front panel of the Tx Splitter:
the MCPA module cable using the N torque wrench
the three DDM cables using the N torque wrench
Note: For tightening torques, see Caution table in Tools required (p. 8-76).
...................................................................................................................................................................................................

11 Reconnect the POWER/DATA cable to the Tx Splitter.


...................................................................................................................................................................................................

12 Reset the Node B by using the TIL tool or from the OMC. For more information, refer to
the following documents:
Alcatel-Lucent 9100 and 93xx Node B - Commissioning and Fault Management User
Manual: TIL, NN-20500-019
Alcatel-Lucent 9353 Management System - User Guide, NN-20500-032
...................................................................................................................................................................................................

13 Ask the OMC administrator to unlock the DDM and MCPA objects previously locked on
step 3. For more information, refer to Alcatel-Lucent 9353 Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

14 Check the state of the Tx Splitter LED (1):

....................................................................................................................................................................................................................................
8-78 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Tx Splitter
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Result: Green LED ON
...................................................................................................................................................................................................

15 Check on the TIL and with the OMC administrator that the Node B is operational.
...................................................................................................................................................................................................

16 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-79
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Replacing a TRDU
Carry out the following procedure to replace a TRDU.
Important! Mixity restriction : TRDU model mixity is not allowed within a cluster.
Note: Make sure that the TRDU module type used as a spare part is identical to the
one to be replaced in the MCDA shelf (TRDU60-21, TRDU60-21B). The left and
right parts of the shelf must consist of three modules of the same type per sector (for
example, S1: TRDU60-21, S2: TRDU60-21B).
Note: To exchange a faulty TRDU module, replace it with a module of the same type
in a group of three identical modules.

Intervention time
15 minutes

Tools required
7/16 torque wrench
Phillips screwdriver
Extraction tool (3JR08430AA)

....................................................................................................................................................................................................................................
8-80 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Figure 8-38 TRDU6021 front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-81
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Figure 8-39 TRDU60-21B front panel

CAUTION
Burn hazard
Module becomes very hot during operation.
Wear gloves when removing the module.

....................................................................................................................................................................................................................................
8-82 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Important! Service is lost on the radio links associated with the TRDU being
replaced.
Important! The 7/16 tightening torque must be 25 N.m (24 N.m to 27 N.m).
Important! Respect bend radius of cables while tightening connectors.
Pay attention to cable torsion and bend radius during maintenance operations.

Procedure
...................................................................................................................................................................................................

1 Locate the faulty TRDU in the TRDU sub-rack: its red LED is on.
...................................................................................................................................................................................................

2 At the OMC, lock the faulty TRDU by Set Administrative State. For more information,
refer to Alcatel-Lucent 9353 Wireless Management System - User Guide, NN-20500-032.
...................................................................................................................................................................................................

3 Switch off the faulty TRDU (on the TRDU front panel, put the power switch in the "O"
position).

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-83
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Figure 8-40 Power switch on the TRDU front panel

...................................................................................................................................................................................................

4 On the front panel of the faulty TRDU, disconnect the following cables:
The two RF antenna cables (connectors labeled "RX" and "TX/RX"), using the 7/16
wrench
The CPRI cable (connector labeled "DATA I/O SLAVE")
The AISG input digital cable (9-pin D-SUB connector labeled "AISG IN"), if CCU
for RETA is used
...................................................................................................................................................................................................

5 Important! Beware that if you do not disconnect the power cable at the
interconnection module, there is a risk of destroying the equipment, because of a
connected -48 V cable hanging down.
First, remove the power cable at the interconnection module (do not remove the data
cable). Then, in front of the faulty TRDU module, disconnect the power cable that is
connected to the "Power IN" connector.
....................................................................................................................................................................................................................................
8-84 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 Untighten the four TRDU front panel screws using the Phillips screwdriver.
...................................................................................................................................................................................................

7 Remove the defective TRDU using the extraction tool.


...................................................................................................................................................................................................

8 Insert the new TRDU.


...................................................................................................................................................................................................

9 Tighten the four screws on the new TRDU front panel using the Phillips screwdriver.
...................................................................................................................................................................................................

10 Check that the power switch on the new TRDU is in the "O" position.
...................................................................................................................................................................................................

11 On the new TRDU front panel, connect the power cable to the "POWER IN" connector.
...................................................................................................................................................................................................

12 DANGER
Personnel protection
When connecting the power cable to the interconnection module, be careful not to touch
the interconnection module.
Connect the power cable to the interconnection module.
...................................................................................................................................................................................................

13 On the new TRDU front panel, connect the following cables:


The AISG input digital cable (9-pin D-SUB connector labeled "AISG IN"), if required
The CPRI cable (connector labeled "DATA I/O SLAVE")
The two RF antenna cables (connectors labeled "RX" and "TX/RX"), using the 7/16
wrench
...................................................................................................................................................................................................

14 Switch on the new TRDU (on the TRDU front panel, put the power switch in the "I"
position).
The TRDU is automatically unlocked.
During TRDU startup, the green and red LEDs on TRDU front panel are on.
Wait for TRDU startup.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-85
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

15 If the TRDU is not automatically unlocked, unlock the TRDU at the OMC by Set
Administrative State. For more information, refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, NN-20500-032.
...................................................................................................................................................................................................

16 On the xCCM front panel, for the CPRI port concerned, check that the Tx and Rx LEDs
are green (the communication is established between the 9311 Macro V2 OD and the new
TRDU).
...................................................................................................................................................................................................

17 On the TRDU front panel, check that:


The green LED is on.
The red LED is off.

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-86 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Overview
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the cooling system equipment

Overview
Purpose
This section presents the replacement procedures applicable to the cooling system of the
9311 Macro OD cabinets.

Contents

Replacing the air filter 8-88


Replacing the ECU control board 8-91
Replacing a fan 8-95
Replacing the ECU ASSY S180 8-99

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-87
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the air filter
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the air filter


Purpose
Perform the following procedure to replace the air filter of the 9311 Macro V2 OD.

Intervention time
Five minutes

Tools required
Phillips screwdriver

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the air filter.


The air filter is located on the upper compartment, in front of the ECU, and maintained by
a door jam. (See legends 1 and 20 in Figure 5-3, 9311 Macro V2 OD 2100 cabinet
layout (p. 5-5).)
...................................................................................................................................................................................................

3 Unscrew the captive screw (4) holding the door jam (2).

....................................................................................................................................................................................................................................
8-88 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the air filter
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Remove the door jam.


...................................................................................................................................................................................................

5 Remove the air filter (1).

Figure 8-41 Air filter replacement

...................................................................................................................................................................................................

6 Take the new filter and insert it.


...................................................................................................................................................................................................

7 Reinsert the door jam holding the air filter.


...................................................................................................................................................................................................

8 Tighten the captive screw on the door jam.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-89
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the air filter
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

9 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-90 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ECU control board
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the ECU control board


Purpose
Carry out the following procedure to replace the ECU control board on the 9311 Macro
V2 OD.

Intervention time
30 minutes

Tools required
Phillips screwdriver
Flat screwdriver

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Switch OFF the ECU breaker on the DDU module.


...................................................................................................................................................................................................

3 Switch OFF the CB02 and CB03 circuit breakers on the ADU module.
...................................................................................................................................................................................................

4 Locate the ECU control board.


....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-91
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ECU control board
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
The ECU control board is located in the control box, on the right side of the upper
compartment.
...................................................................................................................................................................................................

5 Disconnect the two cables (NTT995 PA iss02 cable and DALLAS cable) connected to the
control box.
...................................................................................................................................................................................................

6 Unscrew the captive screw holding the control box.


...................................................................................................................................................................................................

7 Open the control box (pull right).


...................................................................................................................................................................................................

8 Disconnect the nine cables (P1, P2, P3, P9, P10, P11, P12A, P12B, and P13) connected to
the control board.
The following figure indicates the connectors to which cables are connected to the control
board.

....................................................................................................................................................................................................................................
8-92 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ECU control board
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Figure 8-42 ECU control board (connectors)

...................................................................................................................................................................................................

9 Unscrew the five screws (2) on the control board.


...................................................................................................................................................................................................

10 Extract the control board from the control box.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-93
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ECU control board
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

11 Insert a new control board in the control box.


...................................................................................................................................................................................................

12 Tighten the five screws (2) on the control board.


...................................................................................................................................................................................................

13 Connect the nine cables (P1, P2, P3, P9, P10, P11, P12A, P12B, and P13) to the control
board.
...................................................................................................................................................................................................

14 Close the control box (push left).


...................................................................................................................................................................................................

15 Tighten the captive screw holding the control box.


...................................................................................................................................................................................................

16 Connect the NTT995 PA iss02 cable and DALLAS cable to the control box.
...................................................................................................................................................................................................

17 Check that cables are not tended.


...................................................................................................................................................................................................

18 Switch ON the ECU breaker on the DDU module.


...................................................................................................................................................................................................

19 Switch ON the CB02 and CB03 circuit breakers on the ADU module.
...................................................................................................................................................................................................

20 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-94 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a fan
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing a fan
Purpose
Perform the following procedure to replace a fan of the 9311 Macro V2 OD.

Intervention time
15 minutes

Tools required
Phillips screwdriver
8-mm wrench

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

NOTICE
Temperature range
Do not replace a fan when the temperature exceeds the equipment temperature range.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Switch OFF the ECU, the ADU circuit breaker CB01, and the DDU.
...................................................................................................................................................................................................

3 Disconnect the ground wire of the ECU.


...................................................................................................................................................................................................

4 Disconnect the cable with orange connector from the ECU control box (on the right side
of the upper compartment).
...................................................................................................................................................................................................

5 Unscrew the captive screw holding the control box.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-95
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a fan
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 Open the control box (pull right).


...................................................................................................................................................................................................

7 Unscrew the captive screw (M5 F5-99-143) holding the door jam.
...................................................................................................................................................................................................

8 Remove the door jam.


...................................................................................................................................................................................................

9 Turn the two 1/4 turn studs (1), on the left and right sides of the ECU moving part.

Figure 8-43 Fan replacement

...................................................................................................................................................................................................

10 Remove the ECU moving part.

....................................................................................................................................................................................................................................
8-96 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a fan
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

11 Remove the following cables from the fans (2):


NOR 40036 (84828): FAN1-PCB
NOR 40037 (84829): FAN2-PCB
...................................................................................................................................................................................................

12 Remove the ground wire on the fan support (4).


...................................................................................................................................................................................................

13 Unscrew the five 1/4 turn studs on the fan support.


...................................................................................................................................................................................................

14 Remove the fan support.


...................................................................................................................................................................................................

15 Unscrew the four "H-eco-fix" screws (3) holding the fan to its support.
...................................................................................................................................................................................................

16 Change the fan.


...................................................................................................................................................................................................

17 Tighten the four "H-eco-fix" screws holding the fan to its support.
...................................................................................................................................................................................................

18 Reinsert the fan support.


...................................................................................................................................................................................................

19 Tighten the five 1/4 turn studs on the fan support.


...................................................................................................................................................................................................

20 Reinsert the ground wire on the fan support.


...................................................................................................................................................................................................

21 Reconnect the following cables to the fans:


NOR 40036 (84828): FAN1-PCB
NOR 40037 (84829): FAN2-PCB
...................................................................................................................................................................................................

22 Reinsert the ECU moving part.


...................................................................................................................................................................................................

23 Tighten the two 1/4 turn studs.


...................................................................................................................................................................................................

24 Reinsert the door jam.


....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-97
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing a fan
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

25 Tighten the captive screw holding the door jam.


...................................................................................................................................................................................................

26 Close the control box (push left).


...................................................................................................................................................................................................

27 Tighten the captive screw holding the control box.


...................................................................................................................................................................................................

28 Reconnect the cable with orange connector to the control box.


...................................................................................................................................................................................................

29 Reconnect the ECU ground wire.


...................................................................................................................................................................................................

30 Switch ON the ECU, the ADU circuit breaker CB01, and the DDU.
...................................................................................................................................................................................................

31 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-98 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ECU ASSY S180
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the ECU ASSY S180


Purpose
This procedure applies when the damper, the filter clog, or the ambient thermal probe
triggers an alarm.

Intervention time
30 minutes

Tools required
Phillips screwdriver
Cutter-pliers
Ty-raps

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the ECU on the upper compartment of the cabinet.


...................................................................................................................................................................................................

3 Switch OFF the ECU circuit breaker on the DDU board.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-99
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ECU ASSY S180
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Disconnect the ECU ground wire.


...................................................................................................................................................................................................

5 Disconnect the cable with the orange connector from the ECU control box (on the right
side of the ECU).
...................................................................................................................................................................................................

6 Unscrew the captive screw holding the control box.


...................................................................................................................................................................................................

7 Open the control box (pull right).


...................................................................................................................................................................................................

8 Remove the captive screw (4) holding the door jam (2) in front of the ECU.

Figure 8-44 ECU ASSY S180

...................................................................................................................................................................................................

9 Remove the door jam.


....................................................................................................................................................................................................................................
8-100 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ECU ASSY S180
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

10 Remove the air filter (1).


...................................................................................................................................................................................................

11 Turn the two 1/4 turn studs on the left (5) and right (3) sides of the ECU moving part
(ECU ASSY S180).
...................................................................................................................................................................................................

12 Remove the ECU moving part.


...................................................................................................................................................................................................

13 Reinsert the new ECU moving part.


...................................................................................................................................................................................................

14 Tighten the two 1/4 turn studs holding the ECU moving part.
...................................................................................................................................................................................................

15 Reinsert the air filter.


...................................................................................................................................................................................................

16 Reinsert the door jam.


...................................................................................................................................................................................................

17 Tighten the captive screw holding the door jam.


...................................................................................................................................................................................................

18 Close the control box (push left).


...................................................................................................................................................................................................

19 Tighten the captive screw holding the control box.


...................................................................................................................................................................................................

20 Reconnect the cable with the orange connector to the control box.
...................................................................................................................................................................................................

21 Reconnect the ECU ground wire.


...................................................................................................................................................................................................

22 Switch ON the ECU circuit breaker on the DDU board.


...................................................................................................................................................................................................

23 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-101
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Overview

....................................................................................................................................................................................................................................

Replacing the power system equipment

Overview
Purpose
This section presents the replacement procedures applicable to the power system of the
9311 Macro OD cabinets.

Contents

Replacing the ADU module 8-103


Replacing the Cabinet Control Unit (CCU) module 8-107
Replacing the UCPS rectifiers 8-110
Replacing the rectifier rack and DDU 8-112
Replacing the batteries 8-117

....................................................................................................................................................................................................................................
8-102 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ADU module
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the ADU module


Purpose
Perform the following procedure to replace the ADU module of the 9311 Macro V2 OD.
Note: When an ADU lightning protector is defective, an ADU lightning protection
alarm is reported to the OMC. The ADU module must be replaced. To do this, follow
the procedure below.

Intervention time
20 minutes

Tools required
Flat screwdriver
Phillips screwdriver
10-mm wrench

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! During the replacement, the service is lost if the ac box breaks down.
Notify the OMC administrator in case of service interruption.
Important! Before visiting the site, check that there has been no mains power failure
on the site within the last 24 hours. After a mains power failure, the cabinet must
operate on the mains for at least 12 hours to recharge the battery.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-103
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ADU module
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the Node B right door.


...................................................................................................................................................................................................

2 Switch OFF the main Circuit Breakers (CB) on site:


Switch OFF the battery CB below the rectifier.
Switch OFF the three ADU CBs.
Switch OFF the Node B site breakers.
...................................................................................................................................................................................................

3 Disconnect the following cables connected to the ADU, as well as the ground cable:
"ABM/TB - UIA/ADU/MCA/BC" (1)
"ADU - ECU" (3)
"TB - ADU" (4)
"ADU - UCPS" (2)
Ground cable (5)

....................................................................................................................................................................................................................................
8-104 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ADU module
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 8-45 ADU module replacement

...................................................................................................................................................................................................

4 Unscrew the four screws on the ADU corners.


...................................................................................................................................................................................................

5 Remove the ADU.


...................................................................................................................................................................................................

6 Insert the new ADU.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-105
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the ADU module
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

7 Tighten the four screws on the ADU corners.


...................................................................................................................................................................................................

8 Reconnect the five cables on the ADU:


Ground cable (5)
"ADU - UCPS" (2)
"TB - ADU" (4)
"ADU - ECU" (3)
"ABM/TB - UIA/ADU/MCA/BC" (1)
...................................................................................................................................................................................................

9 Switch ON the main CBs on site:


Switch ON the battery CB below the rectifier.
Switch ON the three ADU CBs.
Switch ON the Node B site breakers.
...................................................................................................................................................................................................

10 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

11 Close the Node B right door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-106 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Cabinet Control Unit (CCU) module
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the Cabinet Control Unit (CCU) module


Purpose
Perform the following procedure to replace the CCU module of the 9311 Macro V2 OD.

Intervention time
15 minutes

Tools required
Flat screwdriver
Phillips screwdriver

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! Before visiting the site, check that there has been no mains power failure
on the site within the last 48 hours. After a mains power failure, the cabinet must
operate on the mains for at least 24 hours to reload the batteries.

Procedure
...................................................................................................................................................................................................

1 Open the Node B right door.


....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-107
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Cabinet Control Unit (CCU) module
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Locate the CCU module. (See Figure 5-3, 9311 Macro V2 OD 2100 cabinet layout
(p. 5-5).)
...................................................................................................................................................................................................

3 Switch OFF the three Circuit Breakers (CB) on the ADU.


...................................................................................................................................................................................................

4 Disconnect the following cables from the CCU:


NTT997BA (5)
NTT997AV (4)
NTT995PA (3)

Figure 8-46 CCU module replacement

...................................................................................................................................................................................................

5 Undo the two fixing screws (1) on the CCU front panel.

....................................................................................................................................................................................................................................
8-108 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Cabinet Control Unit (CCU) module
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 Extract the CCU.


...................................................................................................................................................................................................

7 Insert the new CCU module into the cabinet, on the top and bottom edges.
...................................................................................................................................................................................................

8 Tighten the two fixing screws.


...................................................................................................................................................................................................

9 Reconnect the following cables to the CCU:


NTT995PA (3)
NTT997AV (4)
NTT997BA (5)
...................................................................................................................................................................................................

10 Check that the CCU is well set up in the cabinet.


...................................................................................................................................................................................................

11 Switch ON the three CBs on the ADU.


...................................................................................................................................................................................................

12 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

13 Close the Node B right door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-109
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the UCPS rectifiers
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the UCPS rectifiers


Purpose
Perform the following procedure to replace the UCPS rectifiers of the 9311 Macro OD.
Note: This procedure applies to each rectifier.

Intervention time
Five minutes

Tools required
None

Procedure
...................................................................................................................................................................................................

1 Open the Node B right door.


...................................................................................................................................................................................................

2 Locate the defective rectifier.


The rectifiers are located into the UCPS rack (see Figure 5-3, 9311 Macro V2 OD 2100
cabinet layout (p. 5-5)). The defective rectifier displays a red triangular LED.

....................................................................................................................................................................................................................................
8-110 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the UCPS rectifiers
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 8-47 UCPS rectifier module

...................................................................................................................................................................................................

3 Undo the two fixing screws (2) on the front panel of the defective rectifier.
...................................................................................................................................................................................................

4 Extract the defective rectifier using its handle.


...................................................................................................................................................................................................

5 Insert the new rectifier.


...................................................................................................................................................................................................

6 Tighten the two fixing screws.


...................................................................................................................................................................................................

7 Close the Node B right door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-111
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the rectifier rack and DDU
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the rectifier rack and DDU


Purpose
This procedure applies when the DDU or rectifier rack of a 9311 Macro V2 OD triggers
an alarm.
Carry out the following procedure to replace the rectifier rack and DDU.

Intervention time
30 minutes

Tools required
Phillips screwdriver
Torque wrench with socket
7-mm wrench
8-mm wrench
17-mm wrench
Flat screwdriver

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! The tightening torque for the front panel screws must be 0.25 N.m
(0.2375 N.m to 0.2625 N.m).
Important! During the replacement, the service is lost if the ac box breaks down.
Notify the OMC administrator in case of service interruption.

....................................................................................................................................................................................................................................
8-112 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the rectifier rack and DDU
Replacing the power system equipment
....................................................................................................................................................................................................................................
Important! Before visiting the site, check that there has been no mains power failure
on the site within the last 48 hours. After a mains power failure, the cabinet must
operate on the mains for at least 24 hours to reload the batteries.

Procedure
...................................................................................................................................................................................................

1 Open the Node B right door.


...................................................................................................................................................................................................

2 Locate the rectifier rack and DDU board.


The rectifier rack is located at the bottom right of the cabinet and the DDU is in the
rectifier rack.
...................................................................................................................................................................................................

3 Switch OFF the three circuit breakers (CB) on the ADU.


...................................................................................................................................................................................................

4 Switch OFF the battery breaker.


...................................................................................................................................................................................................

5 Undo the six fixing screws (1) on the front panel of the rectifier rack.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-113
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the rectifier rack and DDU
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 8-48 Rectifier rack and DDU board

...................................................................................................................................................................................................

6 Slide out the rack and disconnect the ground cable and three AC connectors on the back
of the rack.
...................................................................................................................................................................................................

7 Disconnect all cables from the DDU board:


NOR 40008
NOR 40011
NOR 40012
NOR 40013
NOR 40014
NOR 40020
NOR 40022
NOR 40049
NOR 40051

....................................................................................................................................................................................................................................
8-114 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the rectifier rack and DDU
Replacing the power system equipment
....................................................................................................................................................................................................................................
NOR 40045
NOR 40055
...................................................................................................................................................................................................

8 Remove the rectifier rack.


...................................................................................................................................................................................................

9 Remove the CCU board. (See Replacing the Cabinet Control Unit (CCU) module
(p. 8-107).)
...................................................................................................................................................................................................

10 Reinsert the CCU board in the new rectifier rack.


...................................................................................................................................................................................................

11 Reconnect all cables to the DDU board:


NOR 40008
NOR 40011
NOR 40012
NOR 40013
NOR 40014
NOR 40020
NOR 40022
NOR 40049
NOR 40051
NOR 40045
NOR 40055
...................................................................................................................................................................................................

12 Position the new rack, connect the ground cable and three AC connectors on its back,
and insert it in place.
...................................................................................................................................................................................................

13 Tighten the six fixing screws on the front panel of the rectifier rack.
...................................................................................................................................................................................................

14 Put the switches on the DDU to the "O" position.


...................................................................................................................................................................................................

15 Switch ON the battery breaker.


...................................................................................................................................................................................................

16 Switch ON the three CBs on the ADU.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-115
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the rectifier rack and DDU
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

17 Put the switches on the DDU to the "I" position.


...................................................................................................................................................................................................

18 Close the Node B right door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-116 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the batteries


Purpose
Perform the following procedure to replace the 9311 Macro V2 OD batteries.

Intervention time
One hour

Tools required
10-mm wrench
Torque wrench with socket

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

WARNING
Electric-shock hazard
Never replace a power supply when energized.
Important! During the replacement, the service is lost if the ac box breaks down.
Notify the OMC administrator in case of service interruption.
Important! Before visiting the site, check that there has no main power failure on the
site within the last 48 hours.
After a mains power failure, the cabinet must operate on the mains for at least 24
hours to reload the batteries.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the batteries at the bottom left of the cabinet.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-117
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

3 Important! Notify the OMC administrator of a service reduction.


If Tx diversity is supported, ask the OMC administrator to lock the mcpa object on the
OMC (by Set Administrative State). For more information, refer to Alcatel-Lucent 9353
Wireless Management System - User Guide, NN-20500-032.
...................................................................................................................................................................................................

4 Switch OFF the battery circuit breaker.

....................................................................................................................................................................................................................................
8-118 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

5 WARNING
Electric-shock hazard
Battery short circuits may be caused from contact with metal objects causing burns to the
face and hands as well as damage to the equipment.
You must therefore ensure the following:
Always use insulated tools when working with or near batteries.
Always use insulated tools when working with or near batteries.
Never place metallic objects on the batteries.
Do not wear jewelry (watches, metal rings or bracelets).
Do not wear outer clothing composed of synthetic material (e.g. nylon).
Remove the NOR 40009 cable. (See legend 3 in Figure 8-49, Batteries cabling
(p. 8-123) figure.)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-119
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 WARNING
Electric-shock hazard
Battery short circuits may be caused from contact with metal objects causing burns to the
face and hands as well as damage to the equipment.
You must therefore ensure the following:
Always use insulated tools when working with or near batteries.
Always use insulated tools when working with or near batteries.
Never place metallic objects on the batteries.
Do not wear jewelry (watches, metal rings or bracelets).
Do not wear outer clothing composed of synthetic material (e.g. nylon).
Remove the NOR 40010 cable. (See legend 5 in Figure 8-49, Batteries cabling
(p. 8-123) figure.)
...................................................................................................................................................................................................

7 WARNING
Electric-shock hazard
Battery short circuits may be caused from contact with metal objects causing burns to the
face and hands as well as damage to the equipment.
You must therefore ensure the following:
Always use insulated tools when working with or near batteries.
Always use insulated tools when working with or near batteries.
Never place metallic objects on the batteries.
Do not wear jewelry (watches, metal rings or bracelets).
Do not wear outer clothing composed of synthetic material (e.g. nylon).
Remove the three cables (usually black; see legend 4 in Figure 8-49, Batteries cabling
(p. 8-123) figure) between batteries, delivered with the battery kit.
Disconnect batteries one by one, starting with terminals (-) at the bottom.
...................................................................................................................................................................................................

8 Important! The personnel working on the batteries must be authorized to work


according to security standards.
Remove the blocking elements:
Two flat washers
Two M8 DIN 125 battery hooks

....................................................................................................................................................................................................................................
8-120 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................
Two M8 wing nuts (see legend 2 in Figure 8-49, Batteries cabling
(p. 8-123) figure.)
The plate blocking the batteries (see legend 1 in Figure 8-49, Batteries cabling
(p. 8-123) figure.)
...................................................................................................................................................................................................

9 Remove the RF diversity cable on the second cell (DDM; see legend 15 in Figure 5-3,
9311 Macro V2 OD 2100 cabinet layout (p. 5-5)) to allow battery removal.

...................................................................................................................................................................................................

10 Remove the four batteries, one by one.


...................................................................................................................................................................................................

11 NOTICE
Working instruction
The four batteries must be identical (brand, data-code, reference number), therefore the
whole set must be replaced.
Replace the batteries only with the same or equivalent type recommended by the
manufacturer.
Dispose of used batteries according to the manufacturer instructions.
Reinsert the four new batteries.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-121
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

12 Reconnect the RF diversity cable on the second cell (DDM).


...................................................................................................................................................................................................

13 Install the blocking elements:


Two flat washers
Two M8 DIN 125 battery hooks
Two M8 wing nuts (2)
The plate blocking the batteries (1)
...................................................................................................................................................................................................

14 Reconnect the three black cables (4).


Reconnect the batteries one by one, starting with terminals (+) on top.
...................................................................................................................................................................................................

15 Reconnect the NOR 40010 cable (5).


...................................................................................................................................................................................................

16 Reconnect the NOR 40009 cable (3).

....................................................................................................................................................................................................................................
8-122 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 8-49 Batteries cabling

...................................................................................................................................................................................................

17 Switch ON the battery circuit breaker.


...................................................................................................................................................................................................

18 Ask the OMC administrator to:


Unlock the MCPA object previously locked on step 3
Check that the Node B is operational.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-123
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the batteries
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

19 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-124 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Overview
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the optional equipment

Overview
Purpose
This section presents the replacement procedures of modules not contained in the digital
shelf and RF block.

Contents

Replacing the Manufacturing Commissioning and Alarm (MCA) module 8-126


Replacing the alarm protection module 8-131
Replacing the double TMA module 8-134
Replacing the light TMA/AISG TMA module 8-139
Replacing the Power Amplifier InterCOnnection (PA ICO) module 8-145
Replacing the Radio Frequency InterCOnnection (RF ICO) module 8-149
Replacing the door gaskets 8-152
Replacing the foam gaskets 8-156
Replacing the door lock 8-160
Replacing the User ICO module 8-164

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-125
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module
....................................................................................................................................................................................................................................

Replacing the Manufacturing Commissioning and Alarm (MCA)


module
Purpose
This procedure applies when the MCA module triggers an alarm.
Carry out the following procedure to replace the MCA module.
Note: The MCA module is hot-swappable, therefore no power-down is required.

Intervention time
Ten minutes

Tools required
Phillips screwdriver
Local Installation Terminal (TIL)

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the OMC administrator of a
service outage before commencing.
Important! The personnel working on the cabinet must be authorized to work
according to the security standards.

Procedure
...................................................................................................................................................................................................

1 Important! If you have to leave the site because it is not possible to obtain an MCA
backup file quickly, do not change the faulty MCA and disconnect the PCM cable
from the CCM front panel.
Open the Node B doors.

....................................................................................................................................................................................................................................
8-126 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Three cases can occur:


Case 1: The CCM is not faulty and was not replaced. Go to Step 3.
Case 2: The CCM has just been replaced. Go to Step 14.
Case 3: During the first site intervention, the MCA backup file was necessary but
impossible to obtain quickly.
For this second intervention, make sure the coordinator sent you the most recent MCA
backup file. If you have a PC (TIL), store the file in the <default
path>/BTS@223.254.244/MCABackup folder. The number after the IC_APPROVED
prefix must be the same as the serial number of the Node B. Go to Step 4.
Note: If the coordinator did not send you the MCA backup file and if it is impossible
to obtain it quickly, do not change the faulty MCA, disconnect the PCM cable from
the CCM front panel, leave the site and come back when you have the appropriate
MCA backup file.
...................................................................................................................................................................................................

3 Apply the "Creating the MCA backup file" procedure defined in Alcatel-Lucent 9100 and
93xx Node B - Commissioning and Fault Management User Manual: TIL,
NN-20500-019.
...................................................................................................................................................................................................

4 Locate the MCA module.


...................................................................................................................................................................................................

5 Disconnect the cable (RoHS PEC: NTN097DF) with three connectors on the MCA.
...................................................................................................................................................................................................

6 Undo the two fixing screws on the MCA front panel.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-127
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module
....................................................................................................................................................................................................................................

Figure 8-50 MCA module replacement

...................................................................................................................................................................................................

7 Remove the MCA.


...................................................................................................................................................................................................

8 Insert the new MCA.


...................................................................................................................................................................................................

9 Tighten the two fixing screws on the MCA front panel.


...................................................................................................................................................................................................

10 Reconnect the cable with three connectors on the MCA.


...................................................................................................................................................................................................

11 Apply the "Updating an empty MCA module" procedure defined in Alcatel-Lucent 9100
and 93xx Node B - Commissioning and Fault Management User Manual: TIL,
NN-20500-019.

....................................................................................................................................................................................................................................
8-128 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

12 If the message is MCA update forbidden, call the next level of support.
...................................................................................................................................................................................................

13 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

14 Close the Node B doors.


...................................................................................................................................................................................................

15 <Following Step 2. Case 2>


Before proceeding, ask the coordinator to send you the most recent MCA backup file.
When you receive the file:
Check the file name. The number after "IC_APPROVED_" prefix must be the same
as the serial number of the Node B.
Ask the coordinator to save the file. If you have a PC (TIL), save the file in the
<Default path>/BTS@223.254.254.244/MCABackup folder. The <Default path> is
the path defined when you executed the TIL procedure.
Note: If it is not possible to receive the file quickly, you should leave the site and
come back when you have the appropriate MCA backup file.
...................................................................................................................................................................................................

16 Locate the MCA module


...................................................................................................................................................................................................

17 Disconnect the cable (RoHS PEC: NTN097DF) with three connectors on the MCA.
...................................................................................................................................................................................................

18 Undo the two fixing screws on the front panel of the MCA.
...................................................................................................................................................................................................

19 Remove the MCA.


...................................................................................................................................................................................................

20 Insert the new MCA.


...................................................................................................................................................................................................

21 Tighten the two fixing screws on the front panel of the MCA.
...................................................................................................................................................................................................

22 Reconnect the cable with three connectors on the MCA.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-129
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

23 Apply the "Updating an empty MCA module" procedure defined in Alcatel-Lucent 9100
and 93xx Node B - Commissioning and Fault Management User Manual: TIL,
NN-20500-019.
...................................................................................................................................................................................................

24 If the message is MCA update forbidden, call the next level of support.
...................................................................................................................................................................................................

25 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

26 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-130 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the alarm protection module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the alarm protection module


Purpose
Perform the following procedure to replace the alarm protection module.

Intervention time
Ten minutes

Tools required
Screwdriver
Wrench for hexagonal head nut (M6 nut)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-131
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the alarm protection module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-51 Alarm protection module front panel

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! Notify the OMC administrator of the alarm protection module
replacement.

....................................................................................................................................................................................................................................
8-132 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the alarm protection module
Replacing the optional equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Locate the alarm protection module in the cabinet.


...................................................................................................................................................................................................

3 Remove the cables from the alarm protection module.


...................................................................................................................................................................................................

4 Remove the two connectors from the bulkhead and undo the wiring.
...................................................................................................................................................................................................

5 Loosen the two front panel screws.


...................................................................................................................................................................................................

6 Remove the defective alarm protection module.


...................................................................................................................................................................................................

7 Insert the new alarm protection module into the cabinet.


...................................................................................................................................................................................................

8 Tighten the two front panel screws.


...................................................................................................................................................................................................

9 Reconnect the cables to the alarm protection module.


...................................................................................................................................................................................................

10 Reconnect the two connectors to the bulkhead and redo the wiring.
...................................................................................................................................................................................................

11 Check with the OMC administrator that all alarms are OK.
...................................................................................................................................................................................................

12 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-133
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the double TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the double TMA module


Purpose
The double TMA module kit includes the following items:
One double TMA module
0ne support plate to fix the TMA on a pole
Carry out the following procedure to replace the TMA module.

Intervention time
15 minutes

Tools required
7/16 torque wrench
13-mm open wrench
Flat screwdriver
Phillips screwdriver
Note: Tightening torques are specified within the procedure.
The following figure shows the double TMA set-up diagram.

....................................................................................................................................................................................................................................
8-134 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the double TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-52 TMA module set-up diagram

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-135
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the double TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................
CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
Turn off and lockout the transmit power before working on the antenna system.
If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna stand-off distances.
Do not use auxiliary antennas.
Consult with the Antenna exposure statements before begining work.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Locate the faulty TMA.


...................................................................................................................................................................................................

2 If the Node B is operational and connected to the OMC, ask the OMC administrator to
lock the sector associated with the faulty TMA (by Set Administrative State). For more
information, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

3 Locate the four RF ports:


MAIN BTS
MAIN ANT
DIV BTS
DIV ANT

....................................................................................................................................................................................................................................
8-136 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the double TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Disconnect the four RF cables from the TMA using the torque wrench.
...................................................................................................................................................................................................

5 Locate the ground port at the bottom of the TMA.


...................................................................................................................................................................................................

6 Disconnect the ground cable by untightening the nut from the TMA using the 13-mm
wrench.
...................................................................................................................................................................................................

7 On the support plate, untighten the four screws on the support side by using the Phillips
screwdriver.
...................................................................................................................................................................................................

8 Untighten the four nuts which firmly anchor the TMA to the support plate, and remove
the faulty TMA module.
...................................................................................................................................................................................................

9 Append the new TMA module and fix it to the support side with all four screws.
...................................................................................................................................................................................................

10 Tighten the four nuts to firmly anchor the TMA to the support plate.
...................................................................................................................................................................................................

11 Locate the ground port at the bottom of the TMA.


...................................................................................................................................................................................................

12 Remove the screw, the two flat washers, and the split washer. Take care not to lose items
during the removal.
...................................................................................................................................................................................................

13 Perform the installation of an eyelet terminal to the ground cable.


...................................................................................................................................................................................................

14 Connect the ground cable to the TMA by assembling the following components in the
following order:
Flat washer
Eyelet terminal
Flat washer
Split washer
Hexagonal nut

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-137
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the double TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

15 Tighten the ground cable using the 13-mm wrench. Check that the other end of the cable
is connected to an efficient ground point.
...................................................................................................................................................................................................

16 Remove the protection caps on the four connectors.


...................................................................................................................................................................................................

17 Reconnect the four RF cables to the TMA.


...................................................................................................................................................................................................

18 Tighten the RF connectors to the TMA using the torque wrench, setting the torque to the
maximum value recommended by the supplier of the 7/16 male connector.
Note: Tighten with 25 N.m in case there is no detailed instruction available from the
connector manufacturer.
Result: The TMA is installed with all connections completed.
...................................................................................................................................................................................................

19 Ask the OMC administrator to unlock the sector associated with the faulty TMA and
previously locked on step 2.
...................................................................................................................................................................................................

20 Check that the TMA LED on the DDM is OFF. For more information about the TMA
LED status, please refer to Alcatel-Lucent 9311 Macro Node B Outdoor Technical
Description, NN-20500-004.
...................................................................................................................................................................................................

21 Check the VSWR LEDs (VSWR thresholds) on the DDM. For more information about
the VSWR LED status, please refer to Alcatel-Lucent 9311 Macro Node B Outdoor
Technical Description, NN-20500-004.
...................................................................................................................................................................................................

22 Check with the OMC administrator that the Node B is operational.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-138 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the light TMA/AISG TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the light TMA/AISG TMA module


Purpose
The light TMA kit includes the following items:
One light TMA module
Two standard hose clamps, two standard mounting brackets, and four nuts to fasten
the brackets to the light TMA
Two mounting brackets for specific antenna mounting and four nuts to fasten the
brackets to the light TMA
Test protocol from factory
For more information about the light TMA and AISG TMA, please refer to Alcatel-Lucent
9311 Macro Node B Outdoor Technical Description, NN-20500-004.
Carry out the following procedure to replace the TMA module.

Intervention time
15 minutes

Tools required
7/16 torque wrench
13-mm open wrench
17-mm torque wrench
Cutting pliers
Note: Tightening torques are specified within the procedure.
The following figure shows the light TMA set-up diagram.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-139
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the light TMA/AISG TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-53 Light TMA module set-up diagram

....................................................................................................................................................................................................................................
8-140 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the light TMA/AISG TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.
Important! Only authorized personnel, with adequate technical training and expertise
with radio base systems will be permitted to operate on the various units. Opening of
enclosed units is not permitted.

CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
Turn off and lockout the transmit power before working on the antenna system.
If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna stand-off distances.
Do not use auxiliary antennas.
Consult with the Antenna exposure statements before begining work.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
You must notify the OMC administrator.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! Observe the general safety precaution against injury and equipment
damage outlined in the regional installation safety manual at all times.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-141
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the light TMA/AISG TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................
Appropriate precautions must be taken to guarantee the safety of staff and equipment.
All operations to perform the connection of the TMA module to the Node B must be
done according to the safety instructions; please contact your Node B supplier for
valid instruction.

Procedure
...................................................................................................................................................................................................

1 Locate the faulty TMA.


...................................................................................................................................................................................................

2 If the Node B is operational and connected to the OMC, ask the OMC administrator to
lock the sector associated with the faulty TMA (by Set Administrative State). For more
information, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

3 Locate the four RF ports:


NODEB 0
NODEB 1
ANT 0
ANT 1
...................................................................................................................................................................................................

4 Disconnect the ground cable by untightening the nut from the TMA using the 13-mm
open wrench.
...................................................................................................................................................................................................

5 Disconnect the four jumper cables from the TMA RF connectors using the 7/16 torque
wrench.
Note: For AISG TMA, disconnect the AISG cable using the 7/16 torque wrench.
...................................................................................................................................................................................................

6 Open the hose clamps by unscrewing the bolt.


...................................................................................................................................................................................................

7 Extract the faulty TMA with both clips mounted.


...................................................................................................................................................................................................

8 Take the new TMA and the two clips.

....................................................................................................................................................................................................................................
8-142 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the light TMA/AISG TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-54 Light TMA module

...................................................................................................................................................................................................

9 Position the clips on the TMA.


...................................................................................................................................................................................................

10 Torque tighten the Nyloc nuts to 3.5 N.m.


Result: The TMA is mounted with both clips.
...................................................................................................................................................................................................

11 Open the hose clamps by unscrewing the bolt.


...................................................................................................................................................................................................

12 Move the steel band into the openings of the TMA mounting equipment.
...................................................................................................................................................................................................

13 Tighten the hose clamp screws carefully. Do not over tighten them.
...................................................................................................................................................................................................

14 Connect the four jumper cables to the TMA RF connectors using the 7/16 torque wrench.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-143
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the light TMA/AISG TMA module
Replacing the optional equipment
....................................................................................................................................................................................................................................
Note: Tightening torques must be the following:
25-30 N.m (35-40 Ibf ft) for 7/16 connectors
6 N.m (8 Ibf ft) for N-type connectors
...................................................................................................................................................................................................

15 For AISG TMA, reconnect the AISG cable using the 7/16 torque wrench. Tightening
torque is 25-30 N.m (35-40 Ibf ft).
Result: The TMA is installed when all connections are completed.
...................................................................................................................................................................................................

16 Reconnect the ground cable using the 13-mm open wrench. Tightening torque is 5 N.m
(3.7 Ibf ft).
...................................................................................................................................................................................................

17 Ask the OMC administrator to unlock the sector associated with the faulty TMA and
previously locked on step 2.
...................................................................................................................................................................................................

18 Check that the TMA LED on the DDM is OFF. For more information about the TMA
LED status, please refer to Alcatel-Lucent 9311 Macro Node B Outdoor Technical
Description, NN-20500-004.
...................................................................................................................................................................................................

19 Check the VSWR LEDs (VSWR thresholds) on the DDM. For more information about
the VSWR LED status, please refer to Alcatel-Lucent 9311 Macro Node B Outdoor
Technical Description, NN-20500-004.
...................................................................................................................................................................................................

20 Check with the OMC administrator that the Node B is operational.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-144 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Power Amplifier InterCOnnection (PA ICO)
Replacing the optional equipment module
....................................................................................................................................................................................................................................

Replacing the Power Amplifier InterCOnnection (PA ICO)


module
Purpose
Perform the following procedure to replace the PA ICO module.

Intervention time
15 minutes

Tools required
Phillips screwdriver
Threaded 10
Ty-raps

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! During the replacement, the service is lost if the AC box breaks down.
Notify the OMC administrator in case of service interruption.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the PA ICO on the upper left side of the cabinet.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-145
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Power Amplifier InterCOnnection (PA ICO)
Replacing the optional equipment module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

3 Switch OFF the RFO breaker on the DDU.


...................................................................................................................................................................................................

4 Unscrew the four screws on the PA ICO.


...................................................................................................................................................................................................

5 Pull the module slightly.


...................................................................................................................................................................................................

6 Disconnect the nine plain-plugs on the back of the PA ICO (see Figure 8-55, PA ICO
module (p. 8-147)).

....................................................................................................................................................................................................................................
8-146 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Power Amplifier InterCOnnection (PA ICO)
Replacing the optional equipment module
....................................................................................................................................................................................................................................

Figure 8-55 PA ICO module

...................................................................................................................................................................................................

7 Disconnect the fasten-lug on the right side of the PA ICO.


...................................................................................................................................................................................................

8 Remove the PA ICO.


...................................................................................................................................................................................................

9 Insert the new PA ICO.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-147
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Power Amplifier InterCOnnection (PA ICO)
Replacing the optional equipment module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

10 Reconnect the fasten-lug on the right side of the PA ICO (RF ICO fuse).
...................................................................................................................................................................................................

11 Reconnect the nine plain-lugs on the back of the PA ICO (see Figure 8-55, PA ICO
module (p. 8-147)).
...................................................................................................................................................................................................

12 Push the module slightly.


...................................................................................................................................................................................................

13 Tighten the four screws on the PA ICO.


...................................................................................................................................................................................................

14 Switch ON the RFO breaker on the DDU.


...................................................................................................................................................................................................

15 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

16 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
8-148 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Radio Frequency InterCOnnection (RF ICO)
Replacing the optional equipment module
....................................................................................................................................................................................................................................

Replacing the Radio Frequency InterCOnnection (RF ICO)


module
Purpose
Perform the following procedure to replace the RF ICO module.

Intervention time
Ten minutes

Tools required
Phillips screwdriver

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! During the replacement, the service is lost if the ac box breaks down.
Notify the OMC administrator in case of service interruption.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the RF ICO on the left column, on top of the three DDMs. (See legend 16 in
Figure 5-3, 9311 Macro V2 OD 2100 cabinet layout (p. 5-5).)
...................................................................................................................................................................................................

3 Switch OFF the four Circuit Breakers (CB) on the DDU.


....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-149
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Radio Frequency InterCOnnection (RF ICO)
Replacing the optional equipment module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Remove all cables from the RF ICO front panel.


...................................................................................................................................................................................................

5 Unscrew the four screws (1) on the RF ICO.


...................................................................................................................................................................................................

6 Pull the module slightly.


...................................................................................................................................................................................................

7 Remove the three plain-lugs (2) located on the right.

Figure 8-56 RF ICO module

...................................................................................................................................................................................................

8 Take a new RF ICO.

....................................................................................................................................................................................................................................
8-150 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the Radio Frequency InterCOnnection (RF ICO)
Replacing the optional equipment module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

9 Connect the three plain-lugs as follows (see Figure 8-56, RF ICO module (p. 8-150)):
Blue cable on top
Black cable in the middle
Green/yellow cable at the bottom
...................................................................................................................................................................................................

10 Push the module slightly.


...................................................................................................................................................................................................

11 Tighten the four screws on the RF ICO.


...................................................................................................................................................................................................

12 Reconnect all cables to the RF ICO front panel.


...................................................................................................................................................................................................

13 Switch ON the four CBs on the DDU.


...................................................................................................................................................................................................

14 Check with the OMC administrator that the Node B is operational.


...................................................................................................................................................................................................

15 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-151
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the door gaskets


Purpose
Perform the following procedure to replace the door gaskets.
Note: To optimize maintenance, door gaskets should be replaced at the same time as
foam gaskets (see Replacing the foam gaskets (p. 8-156)).

Intervention time
30 minutes on each door gasket

Tools required
Flat and Phillips head screwdrivers
Clean lint free cloths
Non-metallic low abrasive pad
Gasket PSA roller (Chromatics Ref.C589R1, Grolleau Ref.0985A)
Rubber gloves (powder free)
One of the following:
3M natural cleaner
Acetone
MEK
Note: To finish cleaning the surface and apply the new gasket, use the following
tools:
Wooden tongue depressor or equivalent
Distilled water
90% or higher concentration alcohol

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

....................................................................................................................................................................................................................................
8-152 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! This procedure requires to be in contact with the OMC administrator.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the gasket on each door.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-153
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-57 Door gasket replacement

...................................................................................................................................................................................................

3 Select one door and unfix the ground wire (1).


...................................................................................................................................................................................................

4 Case 1: If possible, remove the door and position it horizontally.


or
Case 2: Stabilize the door vertically before operating the gasket.
...................................................................................................................................................................................................

5 Remove the old gasket from the aluminium surface.

....................................................................................................................................................................................................................................
8-154 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 Clean the surface as follows:


Use a lint free cloth applicator moistened with solvents to wash the aluminium surface
until the pressure sensitive is removed.
Continue cleaning until all traces of the pressure sensitive adhesive and the film
residue are removed.
Let the surface dry for five minutes at ambient temperature.
...................................................................................................................................................................................................

7 Position the gasket by positioning the four corners of the joint as required.
...................................................................................................................................................................................................

8 Remove the release liner three to four inches at a time.


...................................................................................................................................................................................................

9 Put the gasket in place by pressing firmly on the surface (use the wooden tongue
depressor).
...................................................................................................................................................................................................

10 Check visually that the gasket is correctly fixed.


...................................................................................................................................................................................................

11 Case 1: Put the door back in place.


or
Case 2: Release the door.
...................................................................................................................................................................................................

12 Fix the ground wire.


...................................................................................................................................................................................................

13 Close the door and check visually that gasket compression is OK.
...................................................................................................................................................................................................

14 Repeat the procedure for the second door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-155
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the foam gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the foam gaskets


Purpose
Perform the following procedure to replace the foam gaskets.
Note: To optimize maintenance, foam gaskets should be replaced at the same time as
door gaskets (see Replacing the door gaskets (p. 8-152)).

Intervention time
30 minutes for each foam gasket

Tools required
Flat and Phillips head screwdrivers
Clean lint free cloths
Non-metallic low abrasive pad
Gasket PSA roller (Chromatics Ref.C589R1, Grolleau Ref.0985A)
Rubber gloves (powder free)
One of the following:
3M natural cleaner
Acetone
MEK
Note: To finish cleaning the surface and apply the new gasket, use the following
tools:
Wooden tongue depressor or equivalent
Distilled water
90% or higher concentration alcohol

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

....................................................................................................................................................................................................................................
8-156 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the foam gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1
Note: Check with the OMC administrator that the operational state of the
btsSiteManager object is enabled. For more information about the OMC, please refer
to Alcatel-Lucent 9353 Wireless Management System - User Guide, NN-20500-032.
Open the Node B doors.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-157
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the foam gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-58 Foam gasket replacement

...................................................................................................................................................................................................

2 Select one door and unfix the ground wire.


...................................................................................................................................................................................................

3 Case 1: If possible, remove the door and position it horizontally.


or
Case 2: Stabilize the door vertically before operating the gasket.
...................................................................................................................................................................................................

4 Cut a first foam gasket with length L = 735 mm (horizontal foam gasket).

....................................................................................................................................................................................................................................
8-158 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the foam gaskets
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

5 Cut a second foam gasket with length L = 285 mm (vertical foam gasket).
...................................................................................................................................................................................................

6 Remove the old foam gaskets from the aluminium surface.


...................................................................................................................................................................................................

7 Clean the surface as follows:


Use a lint free cloth applicator moistened with solvents to wash the aluminium surface
until the pressure sensitive is removed.
Continue cleaning until all traces of the pressure sensitive adhesive and the film
residue are removed.
Let the surface dry for five minutes at ambient temperature.
...................................................................................................................................................................................................

8 Position the first foam gasket (L = 735 mm) horizontally as required. (See legends 3 or 4
in Figure 8-58, Foam gasket replacement (p. 8-158).)
...................................................................................................................................................................................................

9 Position the second foam gasket (L = 285 mm) vertically as required. (See legends 2 or 5
in Figure 8-58, Foam gasket replacement (p. 8-158).)
...................................................................................................................................................................................................

10 Remove the release liner three to four inches at a time.


...................................................................................................................................................................................................

11 Put the gaskets in place by pressing firmly on the surface (use the wooden tongue
depressor).
...................................................................................................................................................................................................

12 Case 1: Put the door back in place.


or
Case 2: Release the door.
...................................................................................................................................................................................................

13 Fix the ground wire.


...................................................................................................................................................................................................

14 Close the door and check visually that gasket compression is OK.
...................................................................................................................................................................................................

15 Repeat the procedure for the second door.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-159
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door lock
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the door lock


Purpose
Perform the following procedure to replace the door lock.

Intervention time
15 minutes

Tools required
Phillips screwdriver

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! This procedure requires to be in contact with the OMC administrator.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the lock on the right door.


...................................................................................................................................................................................................

3 Remove the M6 handle screw.


...................................................................................................................................................................................................

4 Put the two lock bolts aside.

....................................................................................................................................................................................................................................
8-160 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door lock
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

5 Remove the four screws holding the two covers inside the door.
...................................................................................................................................................................................................

6 Remove the two screws holding the handle metallic bracelet.

Figure 8-59 Removal of the door lock

...................................................................................................................................................................................................

7 Remove the handle.


...................................................................................................................................................................................................

8 Insert the new handle body on the door.


This new handle must be compatible with the KABA20 cylinder.
...................................................................................................................................................................................................

9 Screw the plastic cover and plastic adaptor with the screw provided in the kit.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-161
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door lock
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

10 Insert the two adaptors: the small in zamak and the other in aluminium on the handle.

Figure 8-60 Reinsertion of the door lock

...................................................................................................................................................................................................

11 Tighten the four screws holding the two covers inside the door.
...................................................................................................................................................................................................

12 Tighten the two lock bolts on the aluminium adaptor.

....................................................................................................................................................................................................................................
8-162 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the door lock
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

13 Tighten the M6 handle screw.


...................................................................................................................................................................................................

14 check the lock


...................................................................................................................................................................................................

15 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-163
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the User ICO module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the User ICO module


Purpose
Perform the following procedure to replace the User ICO module.

Intervention time
Five minutes

Tools required
Phillips screwdriver
Flat blade isolated screwdriver

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Important! If the AC Distribution Unit (ADU) breaks down during the replacement,
the service is lost.
Notify the OMC administrator in case of service interruption.
Note: The User ICO is powered by the DC Distribution Unit (DDU).

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Locate the User ICO module on the upper right side of the cabinet. (See legend 2 in
General Cabinet ViewFigure 5-3, 9311 Macro V2 OD 2100 cabinet layout (p. 5-5).)
The following figure shows the front panel of the User ICO module.

....................................................................................................................................................................................................................................
8-164 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the User ICO module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-61 User ICO module front panel

...................................................................................................................................................................................................

3 Power down the 9311 Macro OD. (See Powering down a 9311 Macro V2 OD (p. 7-2).)
...................................................................................................................................................................................................

4 On the DDU module, lift the protection cover (1) and disconnect the cable of the User
ICO supply (2) from the User ICO connector.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-165
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the User ICO module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 8-62 Disconnection of the User ICO supply cable from the DDU

...................................................................................................................................................................................................

5 Put the protection cover back.


...................................................................................................................................................................................................

6 On the User ICO module, disconnect the cables from the following connectors:
PWR User1, PWR User2, PWR User3, and PWR User4 connectors according to the
User Space used.
UMTS Alarm and User Alarm connectors using the flat blade screwdriver.
...................................................................................................................................................................................................

7 Unscrew the four screws from the User ICO using the Phillips screwdriver.

....................................................................................................................................................................................................................................
8-166 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the User ICO module
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

8 Extract the faulty User ICO module.


...................................................................................................................................................................................................

9 Insert the new User ICO module by passing the supply cable of the module through the
hole.
...................................................................................................................................................................................................

10 Tighten the four screws using the Phillips screwdriver (tightening couple: 289 N.cm +/-
15%).
...................................................................................................................................................................................................

11 On the User ICO module, reconnect the following cables:


PWR cables to PWR User1, PWR User2, PWR User3, and PWR User4 connectors.
Alarm cables to UMTS Alarm and User Alarm connectors using the flat blade
screwdriver.
...................................................................................................................................................................................................

12 Check that all cables are correctly connected on the User ICO module.
...................................................................................................................................................................................................

13 Take the User ICO supply cable, lift the protection cover on the DDU module, plug the
User ICO supply to the User ICO connector, and put the protection cover back.
...................................................................................................................................................................................................

14 Power up the 9311 Macro OD. (See Powering up a 9311 Macro V2 OD (p. 7-4).)
...................................................................................................................................................................................................

15 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary 8-167
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
9311 Macro V2 OD corrective maintenance procedures Replacing the User ICO module

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................
8-168 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Appendix A: Product
conformance statements

Overview
Purpose
This appendix provides the 9311 Macro V2 OD product conformance statements.

Contents

European regulatory requirement compliance A-2


North American regulatory requirements compliance A-4
Compliances for other regions/countries A-8
Operational conditions A-9
Cable specifications A-10
Product labelling A-11

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary A-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements European regulatory requirement compliance

....................................................................................................................................................................................................................................

European regulatory requirement compliance


Overview
As a radio product, the Node B falls under the requirement of the Radio and Telecom
Terminal Equipment (RTTE) European directive 1999/5/EEC. The RTTE directive covers
essential requirements in the field of:
Protection of the Health and Safety of the user and any other person, including the
objectives with respect to safety requirements contained in the Low Voltage directive
(2006/95/EC)
The protection requirements with respect to EMC contained in Directive
2004/108/EC.
The equipment generates, uses, and can radiate radio frequency energy. If not installed
and used in accordance with the instruction manual, the equipment may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference.
The EMC requirements have been selected to ensure an adequate level of
compatibility for apparatus at residential, commercial, and light industrial
environments. The levels however, do not cover extreme cases which may occur in
any location but with a low probability of occurrence. In particular, it may not cover
those cases where a potential source of interference which is producing individually
repeated transient phenomena, or continuous phenomena, is permanently present, for
example a radar or broadcast site in the near vicinity. In such a case it may be
necessary to either limit the source of interference, or use special protection applied,
to the interfered part, or both.
Note: For operation or maintenance inside Alcatel-Lucent systems, the antistatic wrist
shall always be used to maintain the integrity of the product.
Effective use of the Radio spectrum allocated to terrestrial/space radio communication
and orbital resources so as to avoid harmful interference. The routes and standards
used to demonstrate compliance with there essential requirements are outlined in the
following paragraphs.
Node B EMC
Compliance with the essential requirements of EMC has been demonstrated using
EN301489-1 & -23 standard.
Node B radio compliance
Compliance with the essential requirements of effective use of the radio spectrum
has been demonstrated using EN301908-1 & -3 standard.
Node B safety
Compliance with the essential requirements of Safety has been demonstrated
using EN 60950-1 standard.
Node B health protection
....................................................................................................................................................................................................................................
A-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Product conformance statements European regulatory requirement compliance

....................................................................................................................................................................................................................................
Compliance with the essential requirement of health requirement has been
demonstrated using EN50385.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary A-3
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................

North American regulatory requirements compliance


Overview
The 9311 Macro V2 OD has been qualified according to North American market
requirements for the 9311 Macro V2 OD.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
Consult the dealer or an experienced radio/TV technician for help

Node B safety
The 9311 Macro V2 OD comply with UL60950-1 and CAN/CSA C22.2 No. 60950-01
Safety Standards. The CSA mark is applied on the Node B and demonstrates compliance
with both US and Canadian Standards.

Node B EMC and radio compliance


The 9311 Macro V2 OD equipped with 850MHz band radio modules complies with
47CFR Part 15 class B and 47 CFR Part 22 for EMC and radio emission limits according
to US regulatory requirements as indicated on the regulatory label.
The 9311 Macro V2 OD equipped with 1900MHz band radio modules complies with
47CFR Part 15 class B and 47 CFR Part 24 for EMC and radio emission limits according
to US regulatory requirements as indicated on the regulatory label.

Node B interconnection compliance


The 9311 Macro V2 OD comply with 47 CFR Part 68 of the FCC rules and the
requirements adopted by the ACTA.

....................................................................................................................................................................................................................................
A-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................
On the top right of this equipment is a label that contains, among other information, a
product identifier in the following format:
US : U3EXDNANUMTSOUT for the 9311 Macro V2 OD equipped with iCCM2 or
xCCM.
US : AB6XDNANUMTSOUT for the 9311 Macro V2 OD equipped with CCM or
iCCM.
If requested, the following information must be provided to the telephone company:
ACTA Registered Number: U3E, AB6
Facility Interface Code (FIC): 04DU9.BN, 04DU9.DN, 04DU9.1KN, and
04DU9.1SN
Service Order Code (SOC): 6.0F
A FCC part 68 and ACTA compliant cable is provided with the Node B equipment, with
no connector at network interface side. The Node B equipment operates with a 1.544
Mbps digital channel. See Installation Instructions for details.
If the Node B equipment causes harm to the phone network, the telephone company will
notify you in advance that temporary discontinuance of service may be required. But if
advance notice is not practical, the telephone company will notify the customer as soon as
possible. Also, you will be advised of your right to file a complaint with the FCC if you
believe it is necessary
The telephone company may make changes to its facilities, equipment, operations or
procedures that could affect the operation of the equipment. If this happens the telephone
company will provide advance notice so you can make the necessary modifications to
maintain uninterrupted services.
If trouble is experienced with this equipment 9311 Macro V2 OD, for repair or warranty
information, please contact:
Hernan R. Noguchi Global
Product Compliance Laboratory (GPCL)
Alcatel-Lucent
Phone: 1-732-332-6002 101
Crawfords Corner Road Building
11C, Room 165 Holmdel NJ 07733-3030
If the equipment is causing harm to the telephone network, the telephone company may
request that you disconnect the equipment until the problem is resolved.
All repairs should be handled by authorized Alcatel-Lucent Service Personnel.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary A-5
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................
Node B data equipment
The following table shows which jacks are associated with which modes of operation.

Operation Mode USOC Jack


Programmable & Test RJ45S

Node B systems
Facility Interface Codes (FIC), Services Order Codes (SOC), USOC Jack Codes, and
Ringer Equivalence Number (REN) are shown in the table below for each port where
applicable.
For the 9311 Macro V2 OD equipped with CCM or iCCM:

Port FIC SOC USOC Jack REN


CCM T1 board 04DU9.BN 6.0F N/A N/A
CCM T1 board 04DU9.DN 6.0F N/A N/A
CCM T1 board 04DU9.1KN 6.0F N/A N/A
CCM T1 board 04DU9.1SN 6.0F N/A N/A
iCCM T1 board 04DU9.BN 6.0F N/A N/A
iCCM T1 board 04DU9.DN 6.0F N/A N/A
iCCM T1 board 04DU9.1KN 6.0F N/A N/A
iCCM T1 board 04DU9.1SN 6.0F N/A N/A

For the 9311 Macro V2 OD equipped with iCCM2 or xCCM:

Port FIC SOC USOC Jack REN


iCCM2 T1 04DU9.BN 6.0F N/A N/A
board
iCCM2 T1 04DU9.DN 6.0F N/A N/A
board
iCCM2 T1 04DU9.1KN 6.0F N/A N/A
board
iCCM2 T1 04DU9.1SN 6.0F N/A N/A
board
xCCM T1 04DU9.BN 6.0F N/A N/A
board1

....................................................................................................................................................................................................................................
A-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Product conformance statements North American regulatory requirements compliance

....................................................................................................................................................................................................................................

Port FIC SOC USOC Jack REN


xCCM T1 04DU9.DN 6.0F N/A N/A
board1
xCCM T1 04DU9.1KN 6.0F N/A N/A
board1
xCCM T1 04DU9.1SN 6.0F N/A N/A
board1

Notes:
1. equipped with MDA 4E1/T1 PCM links

Node B RF health protection


Compliance with the North American requirements is demonstrated through calculation
according to FCC OET bulletin 65.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary A-7
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements Compliances for other regions/countries

....................................................................................................................................................................................................................................

Compliances for other regions/countries


Overview
For countries outside Europe and the Americas, the requirements of European countries
usually apply.
UMTS 900 MHz is compliant with China RoHS.
It is not possible to list all the applicable approvals/compliances as they will be dependent
on the markets and products considered.
Note: For more information, please contact your local Alcatel-Lucent representative.

....................................................................................................................................................................................................................................
A-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Product conformance statements Operational conditions

....................................................................................................................................................................................................................................

Operational conditions
Overview
The aforementioned standards compliance of the products are based on the following
operating conditions (called normal operation):
Doors shall be closed and/or covers shall be in place.
External cables shall be of the same type as specified by Alcatel-Lucent.
No modification of any mechanical or electrical characteristics of the product shall be
made.
Any change or modification made to the product without written approval from
Alcatel-Lucent releases Alcatel-Lucent from subsequent responsibility regarding the
standards compliance.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary A-9
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements Cable specifications

....................................................................................................................................................................................................................................

Cable specifications
Overview
The compliance to the aforementioned standards has been verified using cables as
specified by Alcatel-Lucent. The continuing compliance of the product relies upon use of
the correct cabling scheme as well as use of identical type cables as specified by
Alcatel-Lucent. Refer to the installation guides for details on cable specifications.

....................................................................................................................................................................................................................................
A-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Product conformance statements Product labelling

....................................................................................................................................................................................................................................

Product labelling
Overview
The label may be located inside or outside the product, provided that the operation and/or
maintenance personnel have the information when working on the product.

Node B labelling for American Countries


To indicate compliance with the CSA and UL Safety requirements, the 9311 Macro V2
OD bears the following mark in a conspicuous location.

On the regulatory label, compliance to 47 CFR Part 15, 22 or 24, and 68 is stated along
with:
FCC ID, FCC Registration Number
Manufacturers name
Equipment designation
Nominal voltage operating range and maximum rated current.

Node B labelling for European Countries


To indicate compliance with the European RTTE Directive, the Node B bears the
following information in a conspicuous location:

Manufacturers name
Equipment designation
Nominal voltage operating range and maximum rated current

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary A-11
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Product conformance statements Product labelling

....................................................................................................................................................................................................................................
Labelling for other regions/countries
Labelling for other regions and countries is performed as appropriate and required by the
local regulatory framework.

....................................................................................................................................................................................................................................
A-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013
Index

C CCM enhanced Channel Element iCEM


See: Core Control Module Module (eCEM) See: integrated Channel
See: Core Control Module Element Module
front view, 8-9
(CCM)
iCEM-2
extended Channel Element
CEM See: integrated Channel
Module (xCEM)
See: Channel Element Module Element Module - 2nd
(CEM) front view, 8-8 generation (iCEM-2)
Channel Element Module (CEM) extended Core Control Module ( integrated Channel Element
xCCM) Module
replace, 8-4
front view, 8-16 front view, 8-5
Core Control Module
extended Transceiver Module integrated Channel Element
front view, 8-14
front view, 8-29 Module - 2nd generation
Core Control Module (CCM) (iCEM-2)
.............................................................
replace, 8-13 front view, 8-5
............................................................. G GPS interface and Alarm module
integrated Core Control Module
front view, 8-23
D DDM front view, 8-14
See: Dual Duplexer Module replace, 8-23 integrated Core Control Module - -
See: Dual Duplexer Module GPSAM 2nd generation (iCCM-2)
(DDM) See: GPS interface and Alarm
front view, 8-15
documentation roadmap, 1-2 module
See: GPS interface and Alarm integrated Transceiver Module
Dual Duplexer Module
module (GPSAM) front view, 8-28
front view, 8-57
.............................................................
iTRM
Dual Duplexer Module (DDM) See: integrated Transceiver
I iCCM
replace, 8-56 See: integrated Core Control Module

............................................................. Module .............................................................

iCCM-2 M MCPA
E eCEM
See: integrated Core Control See: Multi-Carrier Power
See: enhanced Channel
Module - 2nd generation Amplifier module
Element Module (eCEM)
(iCCM-2) See: Multi-Carrier Power
Amplifier module (MCPA)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V2 OD Alcatel-Lucent Proprietary IN-1
NN-20500-011 UA08.1 Use pursuant to applicable agreements
Issue 09.07 January 2013
Index

....................................................................................................................................................................................................................................
Multi-Carrier Power Amplifier .............................................................
module
T Transceiver Module
front view, 8-65
front view, 8-28
Multi-Carrier Power Amplifier
module (MCPA) Transceiver Module (TRM)

replace, 8-64 replace, 8-27

............................................................. TRM
See: Transceiver Module
R replace See: Transceiver Module
(TRM)
Channel Element Module
(CEM), 8-4 .............................................................

Core Control Module (CCM), X xCCM


8-13 See: extended Core Control
Dual Duplexer Module Module
(DDM), 8-56 xCEM
GPS interface and Alarm See: extended Channel
module, 8-23 Element Module (xCEM)

Multi-Carrier Power Amplifier xTRM


module (MCPA), 8-64 See: extended Transceiver
Module
Single-Carrier Power
Amplifier module (SCPA),
8-64
Transceiver Module (TRM),
8-27
roadmap
documentation, 1-2
.............................................................

S Safety statements, 2-1, 2-2

SCPA
See: Single-Carrier Power
Amplifier module
See: Singlei-Carrier Power
Amplifier module (SCPA)
Single-Carrier Power Amplifier
module
front view, 8-67
Single-Carrier Power Amplifier
module (SCPA)
replace, 8-64

....................................................................................................................................................................................................................................
IN-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9311 Macro V2 OD
Use pursuant to applicable agreements NN-20500-011 UA08.1
Issue 09.07 January 2013

Das könnte Ihnen auch gefallen