Alcatel-Lucent 9370
Radio Network Controller | UA08.1
PNNI Hairpin Removal
NN-20500-225
Issue 7.05 | November 2012
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Use pursuant to applicable agreements
Legal notice
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2012 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Trademarks
"Nortel Multiservice Switch", "Nortel Multiservice Data Manager", "Nortel Point of Concentration" are Nortel products.
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Contents
2 Safety statements
3 Hairpin overview
....................................................................................................................................................................................................................................
About hairpins
Hairpin connections
Impacts
5 UA06.0 migration
....................................................................................................................................................................................................................................
iv Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Contents
....................................................................................................................................................................................................................................
SS7 SaalNNI and the IuCs and Iur interfaces
Index
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary v
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Contents
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
vi Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
List of tables
6-1 Aal2If usage for different interfaces and their connections ....................................................................... 6-2
6-2 SaalNni usage for interfaces and their connections .................................................................................... 6-11
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary vii
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
List of tables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
viii Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
List of figures
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary ix
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
List of figures
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
x Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
About this document
About this document
Purpose
This publication describes the procedure for removing the hairpins used as endpoints.
Intended audience
This publication is for operations and maintenance personnel, who are required to modify
RNC hardware and reconfigure the RNC platform.
Supported systems
This document applies to Alcatel-Lucent W-CDMA UA08.1 system release.
This document applies to 9370 RNC.
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary xi
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
About this document
....................................................................................................................................................................................................................................
How to use this document
Start with the first chapter and work through the manual to the end.
Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
Prerequisites
Readers should be familiar with the 3rd Generation Partnership Project (3GPP) Technical
Specification release 99 (R99) and the UMTS specification.
The reconfiguration requirements are based on the network already in place. It is
extremely important that the personnel have the knowledge of their current configuration
in order to anticipate the changes that will occur.
The network should be stable. Any major errors or warnings must be corrected.
Before starting the reconfiguration a snapshot of the current network must be acquired
and each modification should be noted as you progress.
Conventions used
Vocabulary conventions
None
Typographical conventions
The following typographical conventions are used in this document:
Appearance Description
italicized text File and directory names
Emphasized information
graphical user interface text None
variable None
key name None
command-syntax None
input text None
output text None
IP reference, IP number Related document that is referenced in the document
....................................................................................................................................................................................................................................
xii Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
About this document
....................................................................................................................................................................................................................................
Related information
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary xiii
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
About this document
....................................................................................................................................................................................................................................
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
1-888-582-3688 (for the United States)
1-630-224-2485 (for all other countries)
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
....................................................................................................................................................................................................................................
xiv Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
1 1oadmap to Radio
R
Network Controller
documentation
Overview
Purpose
This chapter provides the roadmap for Radio Network Controller documentation.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 1-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Roadmap to Radio Network Controller documentation Roadmap to Radio Network Controller documentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Roadmap to Radio Network Controller documentation Roadmap to Radio Network Controller documentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 1-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Roadmap to Radio Network Controller documentation Roadmap to Radio Network Controller documentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
2 Safety statements
2
Overview
Purpose
This chapter provides information on the structure of safety statements which may arise
in the course of your work.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 2-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
General structure
Safety statements include the following structural elements:
B C D
CAUTION
MP L E
Lifting hazard E F
SA
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
G
Always use three people or a lifting device to transport
and position this equipment. [ABC123]
H
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
(optional)
....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
Signal words
The signal words identify the hazard severity levels as follows:
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 2-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
3 Hairpin overview
3
Overview
Purpose
Hairpins were introduced to act as physical endpoints for some routing applications. With
the Release UA06.0:
The need for more communication ports is created to handle increased traffic capacity.
The software to remove the need for the physical endpoints is improved.
Removing the hairpin to liberate the ports becomes mandatory when:
More than 800 NodeBs are connected to the RNC.
Note: For the NodeBs identified by aal2If =[801 - 1200], the associated
atmConnections are configured on port 808. This can only be done when the PNNI
hairpin resources are re-assigned.
The IuFlex feature is used. This feature is used when several MGW and several
SGSNs that require more atmConnections are present.
The neighboring RNC requires more atmConnections for the Iur interface.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 3-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Hairpin overview Overview
About hairpins
....................................................................................................................................................................................................................................
About hairpins
Overview
Purpose
This section explains the historical origins of the hairpin usage in the RNC.
Contents
....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Hairpin overview Permanent Virtual Connection (PVC)
About hairpins
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 3-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Hairpin overview Soft Permanent Virtual Connections (SPVC)
About hairpins
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Hairpin overview Situating hairpins
Physical position of hairpins
....................................................................................................................................................................................................................................
Situating hairpins
Overview
This section describes the physical positioning of the hairpins in the RNC. The hairpins
are constructed from optical fibers. Making the connection between two adjacent
connectors forms a "U" shape that can resemble a hairpin or bobby pin. The connectors
are part of the 16pOC3 module that is accessible from the rear of the RNC.
This is related only to the cards with the following codes:
NTHW21
NTHW31
NTHW48
Figure 3-1, Typical RNC layout (p. 3-6) shows the physical position of 16pOC3/STM1
in the RNC.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 3-5
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Hairpin overview Situating hairpins
Physical position of hairpins
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Hairpin overview Hairpin connections
Hairpin connections
....................................................................................................................................................................................................................................
Hairpin connections
Hairpin connections
Overview
This section describes the position of hairpins in the 16pOC3 cards, their purpose, and the
physical result after their removal.
Hairpins are used to connect the ports for the Iub, Iu, and Iur interfaces as shown in
Figure 3-2, 16pOC3 with hairpins (p. 3-7).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 3-7
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Hairpin overview Hairpin connections
Hairpin connections
....................................................................................................................................................................................................................................
In Figure 3-2, 16pOC3 with hairpins (p. 3-7), there are:
Three Iub connections going to the POC (ports 0 to 2) in which only two links are
active at any one time. The third connection provides redundancy in case a failure
occurs on the POC.
Two physical hairpins are required to provide the SPVCs for the three IuB interfaces
(port 3-4 and 5-6).
Two Iu/Iur connections go to the Core Network or other RNCs (ports 14 and 15).
Two physical hairpins are required to provide the SPVCs for the two Iu/Iur interfaces
(port 9-10 and 11-12).
In Release UA05.0, AtmMpe, Aal2If, IubIf and SS7 SaalNni use a PVC from one end of
the physical hairpins. At the other end of the hairpin, a source or destination endpoint of
the SPVC is provisioned.
In Release UA06.0, after Aal2If, IubIf and SS7 SaalNni are modified to use SPVC to
connect to their peer counterpart, eight ports become available to add interfaces as shown
in Figure 3-3, 16pOC3 without hairpins (p. 3-9).
The free ports can be used to add links to or connections to:
Other NodeBs
The Core Network
Other RNCs
....................................................................................................................................................................................................................................
3-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Hairpin overview Hairpin connections
Hairpin connections
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 3-9
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Hairpin overview Overview
Impacts
....................................................................................................................................................................................................................................
Impacts
Overview
Impacts of hairpin removal
This section describes some of the impacts that will occur during and after the process of
removing the hairpins to liberate the ports.
The network administrator must ensure that only PNNI 1.0 or UNI 4.0 interfaces are used
for establishing the SPVCs.
Note: IuBC and CBS are not supported with SPVC.
During the removal process
The re-configuration process should be programmed for a period when traffic is limited.
Traffic can be interrupted throughout the re-configuration period.
Note: To avoid traffic disruption, ensure that the hairpin is no longer used before
removing it physically.
Dependability
This feature is not expected to impact the RNC internal dependability, but may improve
the dependability for connectivity over the Iur, IuCS, IuPS and Iub interfaces by
providing alternate routing when an SPVC failure is detected (if an alternate route is
available).
....................................................................................................................................................................................................................................
3-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
4 Hairpin removal process
4
Overview
Purpose
This section describes the procedure to remove the physical hairpins.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 4-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Hairpin removal process Steps for hairpin removal
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
1 Upgrade to the UA06.0 load. For more information on the upgrade procedure, see
Chapter 5, UA06.0 migration.
...................................................................................................................................................................................................
2 Move the endpoints of the SPVCs to AtmMpe, Aal2If, IubIf, and SaalNni. For more
information on moving the endpoints, see Moving the SPVC endpoints (p. 5-2) section.
For re-configuration procedures, see Chapter 6, Procedures for moving endpoints.
...................................................................................................................................................................................................
3 Physically remove the hairpins from the 16pOC3. For more information on the hairpin
removal procedure, see Chapter 8, Removing the hairpins.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
5 UA06.0 migration
5
Overview
Purpose
This section describes hairpin removal process with the UA06.0 upgrade scenario.
The system will default all AtmMpe, Aal2If, IubIf, and SS7 SaalNni to use PVC
connections after upgrading to the UA06.0 RNC load, unless the provisioning for these
components is modified to use SPVCs.
The RNC should be upgraded to Release UA06.0 and then the provisioning must be
changed to replace SPVCs with hairpins to SPVCs without hairpins.
This can be done using WPS or performed manually. Although WPS is recommended,
other configuration managers can perform this task.
For more details about the WPS procedures, see Alcatel-Lucent 9952 Wireless
Provisioning System - User Guide, NN-20500-036.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 5-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
UA06.0 migration Moving the SPVC endpoints
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
UA06.0 migration Moving the SPVC endpoints
....................................................................................................................................................................................................................................
The AtmIf Vcc that has an src component will have the following two attributes:
calledAddress: Contains the NSAP address of the destination endpoint.
calledVpiVci: Contains the VPI.VCI of the Vcc at the destination.
Moving the destination endpoint of the SPVC to the RNC application impacts the
provisioning on the switches that provide the source endpoint of the SPVC. This is
because the source endpoint will have to change the NSAP address and called VPI.VCI of
the new destination endpoint.
When moving the endpoint of the SPVC, the first step is to look at the current
provisioning of all the SPVCs to:
Determine which endpoint of the SPVC is found on the hairpin.
Find the switch and the provisioning that provides the other end of the SPVC. If the
source endpoint is available, some provisioning changes are required.
Determine which PVC/SPVC combination is for which RNC application.
The next steps depend on which interface and for which RNC application the SPVC is
required. Table 5-1, Interface and concerned RNC application (p. 5-4) contains a list of
interfaces, applications, and the steps required to move the endpoint.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 5-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
UA06.0 migration Moving the SPVC endpoints
....................................................................................................................................................................................................................................
Additional tasks
Add a new dlep component dlep/0, which contains two hardware links to both ATM cards
before adding any aal2if stp components. The mainLp of dlep is always set to lp/8 and
spareLp is lp/9. All Aal2if STP components contain a link to dlep/0. The dlep/0
component can be added anytime after the rnc upgrade to V6 and can be configured even
if no aal2/x stp is configured. The dlep component is needed to deliver provisioning data
to the proper software entities. One instance of dlep, dlep/0 is required before any RNC
application SPVC is provisioned.
Note: When adding atmmpe spvc or switching from SPVC with Hairpin to SPVC
without Hairpin you must have feature name "atmmpespvc" implemented into the
Logical processor type associated with OC3 cards ('Sw Lpt featureList).
Note: Any change to the provisioning of an existing SPVC will impact the service
provided by that connection. The current SPVC will be released and the new SPVC
that now terminates on the RNC application will be established. It is recommended to
perform this task during a maintenance window.
When working on the Iur interface that is used to link two or more RNCs together,
changes to the provisioning on one RNC will affect the service of the Iur interface
after it is activated. The connectivity can only be re-established when the provisioning
is completed on the other RNCs. No special code is implemented to minimize the
outage. The changing of the Iur interface configured using WPS procedures and
scripts.
....................................................................................................................................................................................................................................
5-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
UA06.0 migration NodeB to OAM connectivity
....................................................................................................................................................................................................................................
2 Delete the AtmIf Vcc that is providing the NEP that is linked to this AtmMpe/n Ac/m
through the atmConnection attribute.
...................................................................................................................................................................................................
3 Blank out the atmConnection attribute under the AtmMpe/n Ac/m component.
...................................................................................................................................................................................................
5 Set the AtmMpe/n Ac/m SourcePvc remoteAddress to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledAddress.
...................................................................................................................................................................................................
6 Set the AtmMpe/n Ac/m SourcePvc calledVpiVci to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledVpiVci.
...................................................................................................................................................................................................
8 Delete the AtmIf Vcc of the SPVC at the end of the hairpin.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 5-5
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
UA06.0 migration NodeB to OAM connectivity
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
6 6rocedures for moving
P
endpoints
Overview
Purpose
This section introduces the procedures for moving endpoints.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints Introduction
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
Introduction
This section describes the procedure to change from using PVC and SPVC for Aal2If to
use only an SPVC under the Aal2If Path component or Aal2if Alcap SaalUni.
The Aal2If Path SPVC can be used by multiple interfaces to connect to different pieces of
equipment as illustrated in the following table.
Table 6-1 Aal2If usage for different interfaces and their connections
Interface Connecting to
Iub Poc AtmIf Vcc
Open hub Third party ATM switch Vcc
IuCs ALU Core Network AtmIf Vcc
Third party Core Vcc
Iur Another RNC Aal2If Path
Another RNC Aal2If Path via AtmIf Vcc using the hairpin
A third party ATM switch Vcc
For the Iub and IuCs interface, the source endpoint of the SPVC will be provisioned
under the RNC Aal2If Path component. For the Iur interface, the RNC Aal2If Path
component could be the source endpoint or the destination endpoint.
....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Procedures for moving endpoints Iub and open Iub interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
3 Delete the AtmIf Vcc that is providing the NEP that is linked to this Aal2If/n Path/m Nap
atmConnection attribute.
...................................................................................................................................................................................................
6 Set the Aal2If/n Path/m SourcePvc calledAddress to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledAddress.
...................................................................................................................................................................................................
7 Set the Aal2If/n Path/m SourcePvc calledVpiVci to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledVpiVci.
...................................................................................................................................................................................................
9 Delete the AtmIf Vcc of the SPVC at the end of the hairpin.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints IuCs Interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
IuCs Interface
Overview
The following procedure is used to move the SPVC source endpoint for the IuCS
interface to the Aal2If Path component that is used to connect to an AtmIf Vcc on the
RNC Core, or to a third party Core Vcc
Procedure
...................................................................................................................................................................................................
3 Delete the AtmIf Vcc that is providing the NEP that is linked to this Aal2If/n Path/m Nap
atmConnection attribute.
...................................................................................................................................................................................................
6 Set the Aal2If/n Path/m SourcePvc calledAddress to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledAddress.
...................................................................................................................................................................................................
7 Set the Aal2If/n Path/m SourcePvc calledVpiVci to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledVpiVci.
...................................................................................................................................................................................................
9 Delete the AtmIf Vcc of the SPVC at the end of the hairpin.
....................................................................................................................................................................................................................................
6-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Procedures for moving endpoints IuCs Interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-5
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints Iur interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
Iur interface
Overview
When connecting to an Aal2If Path instance on another RNC, the provisioning will
depend on if the Aal2If Path on the other RNC supports the use of SPVC or not. It would
be possible that the other RNC software was not yet upgraded to UA06.0.
If the Iur interface connects two RNCs, you must modify the provisioning on the two
RNCs:
the RNC that will contain the destination endpoint of the SPVC
the RNC that will contain the source endpoint of the SPVC
1 For the RNC that will contain the destination endpoint of the SPVC and is also running
with the UA06.0 load with SPVC support, add the Stp component under the Aal2If/x
instance.
...................................................................................................................................................................................................
3 Delete the AtmIf Vcc that is providing the NEP that is linked to this Aal2If/x Path/y Nap
atmConnection attribute.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Procedures for moving endpoints Iur interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
SPVC source endpoint
Procedure
...................................................................................................................................................................................................
1 For the RNC that contains the SPVC source endpoint, add the Stp component under the
Aal2If/n instance.
...................................................................................................................................................................................................
3 Delete the AtmIf Vcc that is providing the NEP that is linked to this Aal2If/n Path/m Nap
atmConnection attribute.
...................................................................................................................................................................................................
6 For an Iur SPVC connecting to an Aal2If/x Path/y on another RNC with SPVC support:
1. On the other RNC, repeat steps 1 through to 5 to setup the destination endpoint of the
SPVC (as described above).
2. After activation of the provisioning on the other RNC, the new NSAP address will be
found in the Aal2If/x Stp.
3. opLocalAddress operational attribute that is displayed by issuing the CAS command:
d-o aal2If/x stp
4. On this RNC, set the Aal2If/n Path/m SourcePvc calledAddress to the new NSAP
address of the remote Aal2If/x instance by using:
either the value of the opLocalAddress that was printed as part of the output seen
when you issued the "d -o aal2if/x stp" from step b) above
Or the default or provisioned NSAP address
5. On this RNC, set the Aal2If/n Path/m SourcePvc remotePathIdentifier to y, where y is
the remote Aal2If/x Path/y instance.
6. On this RNC, set the Aal2If/n Path/m SourcePvc TrafficManagement
atmServiceCategory, rx/txTrafficDescType, and rx/txTrafficDescParm attributes based
on the value of the old provisioned hairpin SPVCs AtmIf Vcc Vcd Tm attributes.
7. Delete the AtmIf Vcc of the SPVC at the end of the hairpin.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-7
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints Iur interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
8. Activate the provisioning on this RNC.
9. When you have time, cleanup the other RNC provisioning by deleting the Aal2If/x
Path/y Nap subcomponent and the linked Atmif Vcc, and the AtmIf Vcc used to
provide the SPVC through the hairpin.
...................................................................................................................................................................................................
7 For an Iur SPVC connecting to an Aal2If/x Path/y on another RNC without SPVC
support, this means that the SPVC will terminate on an AtmIf Vcc at the end of an hairpin
on the other RNC; or for an Iur SPVC that connects to a third party ATM Vcc:
1. On this RNC, set the Aal2If/n Path/m SourcePvc calledAddress to the value of the old
provisioned hairpin SPVCs AtmIf Vcc Src calledAddress.
2. On this RNC, set the Aal2If/n Path/m SourcePvc calledVpiVci to the value of the old
provisioned hairpin SPVCs AtmIf Vcc Src calledVpiVci.
3. On this RNC, set the Aal2If/n Path/m SourcePvc TrafficManagement
atmServiceCategory, rx/txTrafficDescType and rx/txTrafficDescParm attributes based
on the value of the old provisioned hairpin SPVCs AtmIf Vcc Vcd Tm attributes.
4. Delete the AtmIf Vcc of the SPVC at the end of the hairpin.
5. Activate the provisioning on this RNC.
E...................................................................................................................................................................................................
N D O F S T E P S
These steps will need to be duplicated for all of the PVC/SPVC combination for Aal2If.
Note:
Not all Aal2If SPVCs need to cut over at the same time.
When using SourcePvc RPI (remotePathIdentifier), you must set VPI and VCI to
0 (vcc/0.0).
When using SourcePvc calledVpiVci, you must set RPI (remotePathIdentifier) to
notUsed.
....................................................................................................................................................................................................................................
6-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Procedures for moving endpoints Iub interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
Iub interface
Overview
This procedure is used to change the situation which uses a combination of PVC and
SPVC for IubIf to use only an SPVC.
Procedure
...................................................................................................................................................................................................
2 Delete the AtmIf Vcc that is providing the NEP that is linked to this IubIf/n
SignallingBearer/m Nap atmConnection attribute.
...................................................................................................................................................................................................
5 Set the IubIf/n SignallingBearer/m SourcePvc calledAddress to the value of the old
provisioned hairpin SPVCs AtmIf Vcc Src calledAddress.
...................................................................................................................................................................................................
6 Set the IubIf/n SignallingBearer/m SourcePvc calledVpiVci to the value of the old
provisioned hairpin SPVCs AtmIf Vcc Src calledVpiVci.
...................................................................................................................................................................................................
8 Delete the AtmIf Vcc of the SPVC at the end of the hairpin.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-9
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints Iub interface
Aal2If and the Iub, IuCs and Iur interfaces
....................................................................................................................................................................................................................................
These steps will need to be duplicated for all of the PVC/SPVC combination for IubIf.
Note: Not all IubIf need to cut over to use SPVCs simultaneously.
....................................................................................................................................................................................................................................
6-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Procedures for moving endpoints Overview
SS7 SaalNNI and the IuCs and Iur interfaces
....................................................................................................................................................................................................................................
Introduction
SS7 SaalNni usage for interfaces
Here are the provisioning steps to change from using a combination of PVC and SPVC
for SS7 SaalNni to use only an SPVC under the SS7 SaalNni component.
The SS7 SaalNni can be used by different interfaces to connect to different pieces of
equipment as shown in Table 6-2, SaalNni usage for interfaces and their connections
(p. 6-11).
Interface Connecting to
IuPs Alcatel-Lucent Core AtmlfVcc
A third party Core Vcc
IuCs Alcatel-Lucent Core AtmlfVcc
A third party Core Vcc
Iur Another RNC SS7 SaalNni
Another RNC SS7 SaalNni via AtmIf Vcc using the hairpin
A third party ATM switch Vcc
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-11
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints IuCS and IuPS interfaces
SS7 SaalNNI and the IuCs and Iur interfaces
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
2 Delete the AtmIf Vcc that is providing the NEP that is linked to this SS7 SaalNni/n
through the NAP atmConnection attribute.
...................................................................................................................................................................................................
5 Set the SS7 SaalNni/n SourcePvc calledAddress to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledAddress.
...................................................................................................................................................................................................
6 Set the SS7 SaalNni/n SourcePvc calledVpiVci to the value of the old provisioned hairpin
SPVCs AtmIf Vcc Src calledVpiVci.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Procedures for moving endpoints Iur Interface
SS7 SaalNNI and the IuCs and Iur interfaces
....................................................................................................................................................................................................................................
Iur Interface
Overview
When connecting to a SS7 SaalNni instance on another RNC, the provisioning will
depend on if the SS7 SaalNni on the other RNC supports the use of SPVC or not. It could
be possible that the other RNC software was not yet upgraded to UA06.0.
If the Iur interface is connecting two RNCs together, you will need to modify the
provisioning on two RNCs:
The RNC that will contain the destination endpoint of the SPVC.
The RNC that will contain the source endpoint of the SPVC.
1 For the RNC that will contain the destination endpoint of the SPVC and is also running
with the UA06.0 load with SPVC support, add the Stp component under the SS7
SaalNni/x instance.
...................................................................................................................................................................................................
2 Delete the AtmIf Vcc that is providing the NEP that is linked to this SS7 SaalNni/x Nap
atmConnection attribute.
...................................................................................................................................................................................................
1 For the RNC(a) that contains the SPVC source endpoint used to connect to another SS7
SaalNni on another RNC(b) or to a Vcc on a third party ATM switch, add the Stp
component under the SS7 SaalNni/n instance.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-13
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints Iur Interface
SS7 SaalNNI and the IuCs and Iur interfaces
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 Delete the AtmIf Vcc that is providing the NEP that is linked to this SS7 SaalNni/n via
the Nap atmConnection attribute.
...................................................................................................................................................................................................
5 For an SPVC connecting to SS7 SaalNni/x on another RNC with SPVC support:
1. On the other RNC(b), repeat steps 1 through to 5 to setup the destination endpoint of
the SPV (as described above).
2. After activation of the provisioning on the other RNC(b), the new NSAP address will
be found in the SS7 SaalNni/x Stp.
3. opLocalAddress operational attribute that is displayed by issuing the CAS command:
"d -o aal2If/x stp".
4. On this RNC(b), set the SS7 SaalNni/n SourcePvc calledAddress to the new NSAP
address of the remote SS7 SaalNni/x instance by using:
either the value of the opLocalAddress that was printed as part of the output seen
when you issued the "d -o ss7 saalnni/x stp" from step 2) above.
Or the default or provisioned NSAP address.
5. On this RNC(b), set the SS7 SaalNni/x SourcePvc remoteSaalNniIdentifier to x where
"x" is the remote SS7 SaalNni instance on the other RNC(a).
6. On this RNC(b), set the SS7 SaalNni/x SourcePvc TrafficManagement
atmServiceCategory, rx/txTrafficDescType and rx/txTrafficDescParm attributes based
on the value of the old provisioned hairpin SPVCs AtmIf Vcc Vcd Tm attributes.
7. Delete the AtmIf Vcc of the SPVC at the end of the hairpin.
8. Activate the provisioning on this RNC(b).
9. Cleanup the other RNC(a) provisioning by deleting the SS7 SaalNni/x Nap
subcomponent and the AtmIf Vcc used to provide the SPVC via the hairpin.
...................................................................................................................................................................................................
6 For an SPVC connecting to SS7 SaalNni/x on another RNC without SPVC support, this
means that the SPVC will terminate on an AtmIf Vcc on the other RNC; or if connecting
to a third party ATM switch Vcc:
1. Set the SS7 SaalNni/n SourcePvc calledAddress to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledAddress.
2. Set the SS7 SaalNni/n SourcePvc calledVpiVci to the value of the old provisioned
hairpin SPVCs AtmIf Vcc Src calledVpiVci.
....................................................................................................................................................................................................................................
6-14 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Procedures for moving endpoints Iur Interface
SS7 SaalNNI and the IuCs and Iur interfaces
....................................................................................................................................................................................................................................
3. Set the SS7 SaalNni/n SourcePvc TrafficManagement atmServiceCategory
rx/txTrafficDescType and rx/txTrafficDescParm attributes based on the value of the
old provisioned hairpin SPVCs AtmIf Vcc Vcd Tm attributes.
4. Delete the AtmIf Vcc at the SPVC end of the hairpin.
5. Activate the provisioning on this RNC.
E...................................................................................................................................................................................................
N D O F S T E P S
These steps must be duplicated for all of the PVC/SPVC combinations for all SS7
SaalNni.
Note: When using SourcePvc RSI (remoteSaalNniIdentifier), you must set SourcePvc
VPI and VCI to 0 (vcc/0.0).
When using SourcePvc calledVpiVci, you must set SourcePvc RSI
(remoteSaalNniIdentifier) to notUsed.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 6-15
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Procedures for moving endpoints Iur Interface
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-16 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
7 7 AS commands and PNNI
C
hairpin removal
Overview
Purpose
This section and the following sections describe Channel Associated Signaling (CAS)
commands that are used to re-configure the network when necessary. The commands are
used to configure the AtmMpe, Aal2If, IubIf and SS7 SaalNni applications to comply
with the network requirements.
In the following sections, examples are used to demonstrate different use cases where the
resulting configuration will:
Use ATM PVCs only
Use of a mix of ATM PVCs and SPVC with the help of a physical hairpin
Use ATM SPVCs only
Note: Some CAS commands can be used to verify if, and what traffic is directed to
what endpoint. Before removing a hairpin, it is extremely important to ensure that no
traffic uses the hairpin as an endpoint.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal ATMPE CAS provisioning and operational commands
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal ATMPE CAS provisioning and operational commands
....................................................................................................................................................................................................................................
After this feature is implemented the customer will have three different provisioning
options available when provisioning AtmMpe:
Use ATM PVCs only
Use of a mix of ATM PVCs and SPVC with the help of a physical hairpin
Use ATM SPVCs only
Customers are able to setup AtmMpe to use an ATM SPVC directly but are limited to use
a VPI value of zero (0). Once this feature is implemented this restriction is removed.
When working with SPVCs, you have the option of provisioning a source SPVC or
destination SPVC on the RNC. The following provisioning command examples illustrate
the three options.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal ATMPE CAS provisioning and operational commands
....................................................................................................................................................................................................................................
set atmmpe/1000 ac/49 src calledAddress
45613889902200010F000000000020480D025E00
set atmmpe/1000 ac/49 src calledVpiVci 0.32
set atmmpe/1000 ac/49 src Tm atmServiceCategory constantBitRate
set atmmpe/1000 ac/49 src Tm peakCellRate 60
# If using source SPVC under atmmpe/1000 ac/49
....................................................................................................................................................................................................................................
7-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-5
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
set Aal2If/n AlcapBearer SaalUni/1 SourcePvc TrafficManagement
rxTrafficDescParm
set Aal2If/n AlcapBearer SaalUni/1 SourcePvc TrafficManagement txTrafficDescType
set Aal2If/n AlcapBearer SaalUni/1 SourcePvc TrafficManagement
txTrafficDescParm
After this feature is implemented, the customer will have three different provisioning
options available when provisioning AtmMpe:
Use ATM PVCs only
Use of a mix of ATM PVCs and SPVC with the help of a physical hairpin
Use ATM SPVCs only
Customers are able to setup Aal2If and IubIf to use an ATM PVC. This PVC could be an
AtmIf Vcc on a port that connects to the remote end, or it could be an AtmIf Vcc that is at
the end of a physical hairpin. If a physical hairpin is used, an ATM SPVC is setup at the
other end of the hairpin to connect to the remote end. With this feature customers will be
able to setup Aal2If and IubIf using an ATM SPVC directly.
When working with SPVCs, you have the option of provisioning a source SPVC or
destination SPVC. The following provisioning command examples illustrate the three
options.
Aal2If example
start prov
# Add dlep/0 here
#
add Dlep/0
set Dlep/0 MainLp Lp/8
set Dlep/0 SpareLp Lp/9
# Add Aal2If here
Here are the commands needed for using option 1, for the use of PVCs only
add AtmIf/800 Vcc/0.34 Nep
add AtmIf/800 Vcc/0.35 Nep
add AtmIf/800 Vcc/0.36 Nep
add Aal2If/1 Path/1 Nap
set Aal2If/1 Path/1 Nap atm AtmIf/800 Vcc/0.34 Nep
add Aal2If/1 Path/2 Nap
set Aal2If/1 Path/2 Nap atm AtmIf/800 Vcc/0.35 Nep
add Aal2If/1 AlcapBearer SaalUni/1 Nap
set Aal2If/1 AlcapBearer SaalUni/1 Nap atm AtmIf/800 Vcc/0.36 Nep
# end of the commands needed if using option 1
Here are the commands needed if using option 2, to enable the use of a mix of PVCs and
SPVCs. In this example, there is a physical hairpin between ports 3 and 4. AtmIf/803 and
AtmIf/804 are using ports 3 and 4 respectively.
add AtmIf/803 Vcc/0.34 Nep
add AtmIf/803 Vcc/0.35 Nep
....................................................................................................................................................................................................................................
7-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
add AtmIf/803 Vcc/0.36 Nep
# Using one source SPVC and one destination SPVC
add Atmif/804 Vcc/0.34 Src
set Atmif/804 Vcc/0.34 Src calledAddress
47000012345601234560A110100020480D00C900
set AtmIf/804 Vcc/0.34 Src calledVpiVci 1.32
set AtmIf/804 Vcc/0.34 Vcd Tm atmServiceCategory rtVariableBitRate
set AtmIf/804 Vcc/0.34 Vcd Tm rxTrafficDescType sameAsTx
set AtmIf/804 Vcc/0.34 Vcd Tm rxTrafficDescParm 1 4490 2 898 3 13 4 0 5
0
set AtmIf/804 Vcc/0.34 Vcd Tm txTrafficDescType 6
set AtmIf/804 Vcc/0.34 Vcd Tm txTrafficDescParm 1 4490 2 898 3 13 4 0 5
0
add Atmif/804 Vcc/0.35 Dst
add Atmif/804 Vcc/0.36 Src
set Atmif/804 Vcc/0.36 Src calledAddress
47000012345601234560A110100020480D00C900
set AtmIf/804 Vcc/0.36 Src calledVpiVci 1.33
set AtmIf/804 Vcc/0.36 Vcd Tm atmServiceCategory rtVariableBitRate
set AtmIf/804 Vcc/0.36 Vcd Tm rxTrafficDescType sameAsTx
set AtmIf/804 Vcc/0.36 Vcd Tm rxTrafficDescParm 1 4490 2 898 3 13 4 0 5
0
set AtmIf/804 Vcc/0.36 Vcd Tm txTrafficDescType 6
set AtmIf/804 Vcc/0.36 Vcd Tm txTrafficDescParm 1 4490 2 898 3 13 4 0 5
0
add Aal2If/1 Path/1 Nap add Aal2If/1 Path/2 Nap
set Aal2If/1 Path/1 Nap atm AtmIf/803 Vcc/0.34 Nep
set Aal2If/1 Path/2 Nap atm AtmIf/803 Vcc/0.35 Nep
add Aal2If/1 AlcapBearer SaalUni/1 Nap
set Aal2If/1 AlcapBearer SaalUni/1 atm AtmIf/803 Vcc/0.36 Nep
# end of the commands needed if using option 2
Here are the commands needed if using option 3, use of SPVCs only. Add the SPVC
termination point under the aal2If component.
add Aal2If/1 stp
set Aal2If/1 stp linkToDlep Dlep/0
# Using one source SPVC and one destination SPVC
# The source SPVC is trying to reach an AtmIf Vcc component
add Aal2If/1 Path/1 src
set Aal2If/1 Path/1 src calledAddress
47000012345601234560A110100020480D00C900
set Aal2If/1 Path/1 src calledVpiVci 0.34
set Aal2If/1 Path/1 src Tm atmServiceCategory rtVariableBitRate
set Aal2If/1 Path/1 src Tm rxTrafficDescType sameAsTx
set Aal2If/1 Path/1 src Tm rxTrafficDescParm 1 4490 2 898 3 13 4 0 5 0
set Aal2If/1 Path/1 src Tm txTrafficDescType 6
set Aal2If/1 Path/1 src Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
add Aal2If/1 Path/2 dst
add Aal2If/1 AlcapBearer SaalUni/1 src
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-7
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
set Aal2If/1 AlcapBearer SaalUni/1 src calledAddress
47000012345601234560A110100020480D00C900
set Aal2If/1 AlcapBearer SaalUni/1 src calledVpiVci 0.35
set Aal2If/1 AlcapBearer SaalUni/1 src Tm atmServiceCategory
rtVariableBitRate
set Aal2If/1 AlcapBearer SaalUni/1 src Tm rxTrafficDescType sameAsTx
set Aal2If/1 AlcapBearer SaalUni/1 src Tm rxTrafficDescParm 1 4490 2
898 3 13 4 0 5 0
set Aal2If/1 AlcapBearer SaalUni/1 src Tm txTrafficDescType 6
set Aal2If/1 AlcapBearer SaalUni/1 src Tm txTrafficDescParm 1 60 2 30 3
4 4 250 5 0
# end of the commands needed if using option 3
check prov
act prov
start prov
IubIf commands
The following CAS provisioning commands are supported for IubIf and its
subcomponents:
add IubIf/n Stp or delete IubIf/n Stp
add IubIf/n SignallingBearer/n SaalUni SourcePvc or delete IubIf/n
SignallingBearer/n SaalUni SourcePvc
add IubIf/n SignallingBearer/n SaalUni DestPvc or delete IubIf/n SignallingBearer/n
SaalUni DestPvc
add IubIf/n SignallingBearer/n SaalUni Nap or delete IubIf/n SignallingBearer/n
SaalUni Nap
set IubIf/n Stp softPvcRetryPeriod
set IubIf/n SignallingBearer/n SaalUni SourcePvc calledAddress
set IubIf/n SignallingBearer/n SaalUni SourcePvc calledVpiVci
set IubIf/n SignallingBearer/n SaalUni SourcePvc TrafficManagement
atmServiceCategory
set IubIf/n SignallingBearer/n SaalUni SourcePvc TrafficManagement
rxTrafficDescType
set IubIf/n SignallingBearer/n SaalUni SourcePvc TrafficManagement
rxTrafficDescParm
set IubIf/n SignallingBearer/n SaalUni SourcePvc TrafficManagement
txTrafficDescType
set IubIf/n SignallingBearer/n SaalUni SourcePvc TrafficManagement
txTrafficDescParm
IubIf example
# Add IubIf, SignallingBearer, and SaalUni here
# Here are the commands needed if using option 1, use of PVCs only
....................................................................................................................................................................................................................................
7-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
add AtmIf/800 Vcc/0.50 Nep
add AtmIf/800 Vcc/0.51 Nep
add IubIf/1 SignallingBearer/1 SaalUni Nap
add IubIf/1 SignallingBearer/2 SaalUni Nap
set IubIf/1 SignallingBearer/1 SaalUni Nap atm AtmIf/800 Vcc/0.50 Nep
set IubIf/1 SignallingBearer/2 SaalUni Nap atm AtmIf/800 Vcc/0.51 Nep
# end of the commands needed if using option 1
Here are the commands needed for using option 2, use of a mix of PVCs and SPVCs. In
this example, there is a physical hairpin between ports 3 and 4. AtmIf/803 and AtmIf/804
are using ports 3 and 4 respectively.
add AtmIf/803 Vcc/0.50 Nep
add AtmIf/803 Vcc/0.51 Nep
# Using one source SPVC and one destination SPVC add Atmif/804 Vcc/
0.50 Src
set Atmif/804 Vcc/0.50 Src calledAddress
47000012345601234560A110100020480D00C900
set AtmIf/804 Vcc/0.50 Src calledVpiVci 1.32
set AtmIf/804 Vcc/0.50 Vcd Tm atmServiceCategory rtVariableBitRate
set AtmIf/804 Vcc/0.50 Vcd Tm rxTrafficDescType sameAsTx
set AtmIf/804 Vcc/0.50 Vcd Tm rxTrafficDescParm 1 60 2 30 3 4 4 250 5 0
set AtmIf/804 Vcc/0.50 Vcd Tm txTrafficDescType 6
set AtmIf/804 Vcc/0.50 Vcd Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
Add Atmif/804 Vcc/0.51 Dst
add IubIf/1 SignallingBearer/1 SaalUni Nap
add IubIf/1 SignallingBearer/2 SaalUni Nap
set IubIf/1 SignallingBearer/1 SaalUni Nap atm AtmIf/803 Vcc/0.50 Nep
set IubIf/1 SignallingBearer/2 SaalUni Nap atm AtmIf/803 Vcc/0.51 Nep
# end of the commands needed if using option 2
Here are the commands needed for using option 3, use of SPVCs only. To add the SPVC
termination point under the IubIf component.
add IubIf/1 stp
# Using one source SPVC and one destination SPVC. The source SPVC
is trying to reach an AtmIf Vcc component.
add IubIf/1 SignallingBearer/1 SaalUni src
set IubIf/1 SignallingBearer/1 SaalUni src calledAddress
47000012345601234560A110100020480D00C900
set IubIf/1 SignallingBearer/1 SaalUni src calledVpiVci 0.50
set IubIf/1 SignallingBearer/1 SaalUni src Tm atmServiceCategory
rtVariableBitRate
set IubIf/1 SignallingBearer/1 SaalUni src Tm rxTrafficDescType sameAsTx
set IubIf/1 SignallingBearer/1 SaalUni src Tm rxTrafficDescParm 1 60 2
30 3 4 4 250 5 0
set IubIf/1 SignallingBearer/1 SaalUni src Tm txTrafficDescType 6
set IubIf/1 SignallingBearer/1 SaalUni src Tm txTrafficDescParm 1 60 2
30 3 4 4 250 5 0
add IubIf/1 SignallingBearer/2 SaalUni dst
# end of the commands needed if using option 3
check prov
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-9
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
act prov
....................................................................................................................................................................................................................................
7-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
To verify the state after re-configuration
The following command can be useful to verify the states after switching SPVC with
hairpin to SPVC without Hairpin:
Command: d atmif/* vcc/* ep
Example
d atmif/* vcc/* ep
AtmIf/* Vcc/* Ep
+=====+==========+------------------+------
|AtmIf| Vcc | applicationName |Response
+=====+==========+------------------+------
| 800|0.5 |AtmIf/800 Pnni Sig |
| 800|0.18 |AtmIf/800 Pnni Rcc |
| 800|0.14436 |Aal2If/350 Path/4426|
| | | AtmCon |
| 800|0.14485 |Ss7 SaalNni/34 |
| | | AtmCon |
| 800|0.14517 |Aal2If/80 Path/1265 |
| | | AtmCon |
| 800|0.14518 |AtmMpe/1000 Ac/80 |
| | | AtmCon |
| 803|0.5 |AtmIf/803 Pnni Sig |
| 803|0.18 |AtmIf/803 Pnni Rcc |
| 803|0.13998 |Ss7 SaalNni/33 |
| | | AtmCon |
| 803|0.14024 |Aal2If/80 Path/1279 |
| | | AtmCon |
| 803|0.14025 |Aal2If/80 Path/1271 |
| | | AtmCon |
| 803|0.14026 |Aal2If/80 Path/1272 |
| | | AtmCon |
| 803|0.14027 |Aal2If/80 Path/1269 |
| | | AtmCon |
| 803|0.14028 |Aal2If/80 Path/1270
| | | AtmCon |
| 803|0.14029 |Aal2If/80 Path/1278 |
| | | AtmCon |
| 803|0.14030 |Aal2If/80 Alcap |
| | | AtmCon |
| 803|0.14031 |Aal2If/80 Path/1277 |
| | | AtmCon |
| 803|0.14032 |Aal2If/80 Path/1280 |
| | | AtmCon |
| 803|0.14033 |Iub/80 Sig/0 SaalUni
| | | AtmCon |
| 803|0.14034 |Iub/80 Sig/2 SaalUni|
| | | AtmCon |
| 803|0.14035 |Iub/80 Sig/1 SaalUni|
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-11
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf provisioning commands
....................................................................................................................................................................................................................................
| | | AtmCon |
| 803|0.16367 |Aal2If/350 Path/4473|
| | | AtmCon |
| 803|0.16368 |Aal2If/350 Path/4433|
| | | AtmCon |
ok 2008-10-27 19:08:20.88
....................................................................................................................................................................................................................................
7-12 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf operational commands
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-13
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf operational commands
....................................................................................................................................................................................................................................
To verify the flow across the UTRAN network:
...................................................................................................................................................................................................
2 Verify that ATM cells are sent out to the calling endpoint of the SPVC:
display AtmIf/<n> vcc/ <vpi.vci> from 1. above
Observe the txCell count attributes.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-14 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal Aal2If and IubIf operational commands
....................................................................................................................................................................................................................................
If the SPVC was previously established, identify the reason for the last connection tear
down by using the following operator command:
display Aal2If/<n> Path/<n> SrcPvc lastClearCause
display Aal2If/<n> AlcapBearer SaalUni/1 SrcPvc lastClearCause
display IubIf/<n> SignallingBearer/<n> SaalUni SrcPvc lastClearCause
or
display Aal2If/<n> Path/<n> DstPvc lastClearCause
display Aal2If/<n> AlcapBearer SaalUni/1 DstPvc lastClearCause
display IubIf/<n> SignallingBearer/<n> SaalUni DstPvc lastClearCause
If the SPVC was not previously established, there is likely a misconfiguration at one or
both endpoints of the SPVC.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-15
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal SS7 SaalNni CAS provisioning commands
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
# other SS7 provisioning command here
add ss7 saalnni/1
add ss7 saalnni/2
add ss7 saalnni/17
add ss7 saalnni/18
add ss7 saalnni/33
add ss7 saalnni/34
When using option 1, use PVCs only:
add AtmIf/815 Vcc/1.32 Nep
add AtmIf/815 Vcc/1.33 Nep
add AtmIf/815 Vcc/2.32 Nep
add AtmIf/815 Vcc/2.33 Nep
add AtmIf/815 Vcc/3.32 Nep
add AtmIf/815 Vcc/3.33 Nep
add ss7 saalnni/1 nap
add ss7 saalnni/2 nap
add ss7 saalnni/17 nap
add ss7 saalnni/18 nap
add ss7 saalnni/33 nap
add ss7 saalnni/34 nap
set ss7 saalnni/1 nap atm AtmIf/815 Vcc/1.32 Nep
set ss7 saalnni/2 nap atm AtmIf/815 Vcc/1.33 Nep
set ss7 saalnni/17 nap atm AtmIf/815 Vcc/2.32 Nep
set ss7 saalnni/18 nap atm AtmIf/815 Vcc/2.33 Nep
set ss7 saalnni/33 nap atm AtmIf/815 Vcc/3.32 Nep
set ss7 saalnni/34 nap atm AtmIf/815 Vcc/3.33 Nep
# end of the commands needed if using option 1
The commands needed when using option 2, to use of a mix of PVCs and SPVCs are as
follows. In this example, there is a physical hairpin between ports 11 and 12. AtmIf/811
and AtmIf/812 are using ports 11 and 12 respectively.
add AtmIf/811 Vcc/1.32 Nep
add AtmIf/811 Vcc/1.33 Nep
add AtmIf/811 Vcc/2.32 Nep
add AtmIf/811 Vcc/2.33 Nep
add AtmIf/811 Vcc/3.32 Nep
add AtmIf/811 Vcc/3.33 Nep
# Using three source SPVCs and three desination SPVCs
add Atmif/812 Vcc/1.32 Src
set Atmif/812 Vcc/1.32 Src calledAddress
47000012345601234560A110100020480D00C900
set AtmIf/812 Vcc/1.32 Src calledVpiVci 1.32
set AtmIf/812 Vcc/1.32 Vcd Tm atmServiceCategory rtVariableBitRate
set AtmIf/812 Vcc/1.32 Vcd Tm rxTrafficDescType sameAsTx
set AtmIf/812 Vcc/1.32 Vcd Tm rxTrafficDescParm 1 60 2 30 3 4 4 250 5 0
set AtmIf/812 Vcc/1.32 Vcd Tm txTrafficDescType 6
set AtmIf/812 Vcc/1.32 Vcd Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
add Atmif/812 Vcc/1.33 Dst
add Atmif/812 Vcc/2.32 Src
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-17
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal SS7 SaalNni CAS provisioning commands
....................................................................................................................................................................................................................................
set Atmif/812 Vcc/2.32 Src calledAddress
47000012345601234560A220200020480D123400
set AtmIf/812 Vcc/2.32 Src calledVpiVci 2.32
set AtmIf/812 Vcc/2.32 Vcd Tm atmServiceCategory rtVariableBitRate
set AtmIf/812 Vcc/2.32 Vcd Tm rxTrafficDescType sameAsTx
set AtmIf/812 Vcc/2.32 Vcd Tm rxTrafficDescParm 1 60 2 30 3 4 4 250 5 0
set AtmIf/812 Vcc/2.32 Vcd Tm txTrafficDescType 6
set AtmIf/812 Vcc/2.32 Vcd Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
add Atmif/812 Vcc/2.33 Dst
add Atmif/812 Vcc/3.32 Src
set Atmif/812 Vcc/3.32 Src calledAddress
47000012345601234560A110100020480D022200
set AtmIf/812 Vcc/3.32 Src calledVpiVci 3.32
set AtmIf/812 Vcc/3.32 Vcd Tm atmServiceCategory rtVariableBitRate
set AtmIf/812 Vcc/3.32 Vcd Tm rxTrafficDescType sameAsTx
set AtmIf/812 Vcc/3.32 Vcd Tm rxTrafficDescParm 1 60 2 30 3 4 4 250 5 0
set AtmIf/812 Vcc/3.32 Vcd Tm txTrafficDescType 6
set AtmIf/812 Vcc/3.32 Vcd Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
add Atmif/812 Vcc/3.33 Dst
add ss7 saalnni/1 nap
add ss7 saalnni/2 nap
add ss7 saalnni/17 nap
add ss7 saalnni/18 nap
add ss7 saalnni/33 nap
add ss7 saalnni/34 nap
set ss7 saalnni/1 nap atm AtmIf/811 Vcc/1.32 Nep
set ss7 saalnni/2 nap atm AtmIf/811 Vcc/1.33 Nep
set ss7 saalnni/17 nap atm AtmIf/811 Vcc/2.32 Nep
set ss7 saalnni/18 nap atm AtmIf/811 Vcc/2.33 Nep
set ss7 saalnni/33 nap atm AtmIf/815 Vcc/3.32 Nep
set ss7 saalnni/34 nap atm AtmIf/815 Vcc/3.33 Nep
# end of the commands needed if using option 2
The following commands are used when using option 3, to use SPVCs only. To add the
SPVC termination point under the SaalNni component:
add ss7 saalnni/1 stp
add ss7 saalnni/2 stp
add ss7 saalnni/17 stp
add ss7 saalnni/18 stp
add ss7 saalnni/33 stp
add ss7 saalnni/34 stp
# Using three source SPVCs and three desination SPVCs
# All three source SPVCs are trying to reach an AtmIf Vcc component
add ss7 saalnni/1 src
set ss7 saalnni/1 src calledAddress
47000012345601234560A110100020480D00C900
set ss7 saalnni/1 src calledVpiVci 1.32
set ss7 saalnni/1 src Tm atmServiceCategory rtVariableBitRate
set ss7 saalnni/1 src Tm rxTrafficDescType sameAsTx
set ss7 saalnni/1 src Tm rxTrafficDescParm 1 60 2 30 3 4 4 250 5 0
....................................................................................................................................................................................................................................
7-18 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal SS7 SaalNni CAS provisioning commands
....................................................................................................................................................................................................................................
set ss7 saalnni/1 src Tm txTrafficDescType 6
set ss7 saalnni/1 src Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
add ss7 saalnni/2 dst
add ss7 saalnni/17 src
set ss7 saalnni/17 src calledAddress
47000012345601234560A220200020480D123400
set ss7 saalnni/17 src calledVpiVci 2.32
set ss7 saalnni/17 src Tm atmServiceCategory rtVariableBitRate
set ss7 saalnni/17 src Tm rxTrafficDescType sameAsTx
set ss7 saalnni/17 src Tm rxTrafficDescParm 1 60 2 30 3 4 4 250 5 0
set ss7 saalnni/17 src Tm txTrafficDescType 6
set ss7 saalnni/17 src Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
add ss7 saalnni/18 dst
add ss7 saalnni/33 src
set ss7 saalnni/33 src calledAddress
47000012345601234560A110100020480D022200
set ss7 saalnni/33 src calledVpiVci 3.32
set ss7 saalnni/33 src Tm atmServiceCategory rtVariableBitRate
set ss7 saalnni/33 src Tm rxTrafficDescType sameAsTx
set ss7 saalnni/33 src Tm rxTrafficDescParm 1 60 2 30 3 4 4 250 5 0
set ss7 saalnni/33 src Tm txTrafficDescType 6
set ss7 saalnni/33 src Tm txTrafficDescParm 1 60 2 30 3 4 4 250 5 0
add ss7 saalnni/34 dst
# end of the commands for using option 3
The following is an example of commands for a SaalNni SPVC terminating on a
destination SPVC under SS7 SaalNni/34 that resides on another RNC.
add ss7 saalnni/34 src
set ss7 saalnni/34 src calledAddress
47000012345601234560A110100020480DC0C902
set ss7 saalnni/34 src remoteSaalNniIdentifier 34
check prov
act prov
conf prov
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 7-19
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
CAS commands and PNNI hairpin removal SS7 SaalNni CAS operational commands
....................................................................................................................................................................................................................................
1 To find out on which AtmIf VCC the SPVC has been established:
display SS7 SaalNni/<n> atmCon nextHop
Observe the AtmIf/n vcc/vpi.vci.
...................................................................................................................................................................................................
2 Verify that ATM cells are sent out the calling endpoint of the SaalNni SPVC:
display AtmIf/<n> vcc/<vpi.vci> from 1. above
Observe the txCell count attributes.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
display AtmIf/<n> Vcc/ <vpi.vci> from 1. above
Observe the rxCell count.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
This command could be used in a situation where you have two fibers that provides
connectivity to the destination and you need to replace the fiber on which the SPVCs
have been established. In this situation you can use the clear command and lock the port
on which you need to replace the fiber. This will force the SPVCs to establish on the other
link.
Note: The CAS clear command can be executed on either the calling or called
endpoint of an SaalNni SPVC.
....................................................................................................................................................................................................................................
7-22 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
8 Removing the hairpins
8
Overview
Purpose
The final step to liberate the ports is the physical removal of the fiber between the two
ports used by the physical hairpin.
This can be done at any time that is convenient to the customer or the technician (after the
migration of services over hairpin is completed) and does not need to be done
immediately.
The ports that are liberated can then be used to add extra links for the Iub, Iu and Iur
interfaces.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 8-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Removing the hairpins Tools for hairpin removal
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Removing the hairpins Removing the hairpin
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Contact with equipment without the anti-static protection can cause injury.
All usual precautions concerning electrical telephony equipment and anti-static
protection must be taken into account for this procedure.
The following procedure is used to liberate the ports by removing the physical hairpins.
Note: The physical removal of the hairpin must only be attempted after all the
reconfiguration is completed.
Figure 8-1, 16pOC3 module (p. 8-4) shows the module with the cover open to access
the optical connections. In this figure no optical cables, hairpins or protectors are installed
on or connected to the Tx/Rx fiber ports.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 8-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Removing the hairpins Removing the hairpin
....................................................................................................................................................................................................................................
Procedure
Use the following procedure to remove the hairpins.
...................................................................................................................................................................................................
3 Lift the cable connection cover to expose the connections to the 16pOC3 module.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Removing the hairpins Removing the hairpin
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
8 Check that the action has not created any additional port alarms and that the RNC is
functioning correctly.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary 8-5
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Removing the hairpins Removing the hairpin
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Appendix A: Product
conformance statements
Overview
Purpose
This appendix presents the product conformance statements that apply to the
Alcatel-Lucent 9370 Radio Network Controller.
In regions such as North America and the European Union, the statements that are
required are determined primarily by national or multi-national regulations. However, in
some regions, contract terms determine the required statements.
The presence of the statement indicates that the product does comply with that statement
wherever it is required to do so.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary A-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Product conformance statements Regulatory requirement compliance
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
A-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Product conformance statements Compliance for Canada
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary A-3
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Product conformance statements Compliance for Canada
....................................................................................................................................................................................................................................
Eco-Environmental Statements
Packaging collection and recovery requirements
Countries, states, localities, or other jurisdictions may require that systems be established
for the return and/or collection of packaging waste from the consumer, or other end user,
or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the
return and/or collection of the packaging waste may be established. For more information
regarding collection and recovery of packaging and packaging waste within specific
jurisdictions, contact the Alcatel-Lucent Environment, Health and Safety organization.
....................................................................................................................................................................................................................................
A-4 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Product conformance statements Compliance for China
....................................................................................................................................................................................................................................
Eco-Environmental Statements
Packaging collection and recovery requirements
Countries, states, localities, or other jurisdictions may require that systems be established
for the return and/or collection of packaging waste from the consumer, or other end user,
or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the
return and/or collection of the packaging waste may be established. For more information
regarding collection and recovery of packaging and packaging waste within specific
jurisdictions, contact the Alcatel-Lucent Environment, Health and Safety organization.
Material content compliance
The People's Republic of China Ministry of Information Industry has published a
regulation (Order #39) and associated standards regarding restrictions on hazardous
substances (China RoHS). Currently, the legislation requires all Electronic and
Information Products (EIP) to comply with certain labeling and documentation
requirements. Alcatel-Lucent products manufactured on or after 1 March 2007, that are
intended for sale to customers in the China market, must comply with these requirements.
In accordance with the People's Republic of China Electronic Industry Standard Marking
for the Control of Pollution Caused by Electronic Information Products
(SJ/T11364-2006), customers may access the Alcatel-Lucent Hazardous Substances Table
at (http://www.alcatel-sbell.com.cn/wwwroot/images/upload/private/1/media/ChinaRoHS.
pdf).
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary A-5
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Product conformance statements Compliance for European Union
....................................................................................................................................................................................................................................
CE Marking Statement
This product has been CE-marked in accordance with the following European Directives:
Directive 1999/5/EC Radio and Telecommunication Terminal Equipment (R&TTE) of
the European Parliament and of the council.
Directive 2004/108/EC Electromagnetic Compatibility (EMC)
Directive 73/23/EEC Low Voltage Directive (LVD)
Directive 2002/96/EC Waste Electrical and Electronic Equipment (WEEE)
Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in
Electrical and Electronic Equipment (RoHS)
EMC compliance
The equipment complies with the following EMC specifications:
EN 300 386 (Europe)
EN 55022 (Europe) Class B
EN 55024 (Europe)
....................................................................................................................................................................................................................................
A-6 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Product conformance statements Compliance for European Union
....................................................................................................................................................................................................................................
CB Report is issued by CSA and provides regulatory safety compliance to International
and European markets and covers the following standards:
IEC 60950-1 Information technology equipment - Safety - Part 1: General
requirements International Regulatory Safety Standard.
EN 60950-1 Information technology equipment - Safety Part 1: General requirements
European Standard Regulatory Safety Standard.
9370 RNC CB Report
Reference number: CB 154792-1889473
Certificate Reference: CA/8762M2/CSA
Eco-environmental Statements
Packaging collection and recovery requirements
Countries, states, localities, or other jurisdictions may require that systems be established
for the return and/or collection of packaging waste from the consumer, or other end user,
or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the
return and/or collection of the packaging waste may be established. For more information
regarding collection and recovery of packaging and packaging waste within specific
jurisdictions, contact the Alcatel-Lucent Environment, Health and Safety organization.
Recycling / take-back / disposal of products and batteries
Electronic products and batteries bearing or referencing the symbols shown below shall
be collected and treated at the end of their useful life, in compliance with applicable
European Union and other local legislation. They shall not be disposed of as part of
unsorted municipal waste. Due to materials that may be contained in the product and
batteries, such as heavy metals, the environment and human health may be negatively
impacted as a result of inappropriate disposal.
Note: For electronic products put on the market in the European Union, a solid bar
under the crossed-out wheeled bin indicates that the product was put on the market
after 13 August 2005.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary A-7
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Product conformance statements Compliance for European Union
....................................................................................................................................................................................................................................
Note: For batteries put on the market in the European Union, a chemical symbol Hg
(mercury), Cd (cadmium), or Pb (lead), or a combination of those symbols, beneath
the cross-out wheeled bin indicates that the battery contains the corresponding heavy
metals.
....................................................................................................................................................................................................................................
A-8 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Product conformance statements Compliance for United States
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary A-9
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Product conformance statements Compliance for United States
....................................................................................................................................................................................................................................
Any modifications to this equipment are not permitted without review and official written
authorization from the specific Certification Body. Unauthorized changes may violate the
Product Safety Certification. Modifications or changes authorized by official CN/CNN
are assumed to have received prior approval from this lab.
Indoor applications
This equipment is intended for installation in restricted access locations where access is
controlled or where access can only be gained by service personnel with a key or tool.
Access to this equipment is restricted to qualified service personnel only.
Eco-Environmental statements
Packaging collection and recovery requirements
Countries, states, localities, or other jurisdictions may require that systems be established
for the return and/or collection of packaging waste from either the consumer or the end
user, or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for
the return and/or collection of the packaging waste may be established. For more
information regarding collection and recovery of packaging and packaging waste within
specific jurisdictions, contact the Alcatel-Lucent Environment, Health and Safety
organization or Alcatel-Lucent Hazardous Waste Center technical support at (888)
539-2783.
Material content compliance
The following notification applies to Alcatel-Lucent products distributed for sale, resale,
or use.
This product, part, or both may include a lithium-manganese dioxide battery, which
contains very small amounts of a perchlorate substance. Special handling may apply.
For California
Perchlorate Material - special handling may apply. See www.dtsc.ca.gov/hazardouswaste/
perchlorate.
....................................................................................................................................................................................................................................
A-10 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012
Index
.............................................................
.............................................................
R roadmap
documentation, 1-2
.............................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9370 RNC Alcatel-Lucent Proprietary IN-1
NN-20500-225 UA08.1 Use pursuant to applicable agreements
Issue 7.05 November 2012
Index
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
IN-2 Alcatel-Lucent Proprietary Alcatel-Lucent 9370 RNC
Use pursuant to applicable agreements NN-20500-225 UA08.1
Issue 7.05 November 2012