Sie sind auf Seite 1von 6

Wednesday, March 29, 2017, 04:56 PM

PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries6/Academic *
* Version 20.07.11.50 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= MAR 29, 2017 *
* Time= 16:54:35 *
* *
* USER ID: Facultad de Ingeniera *
****************************************************

1. STADD SPACE ARMADURA


INPUT FILE: C:\Users\Usuario1\Documents\septimo semestre\staad\ARMA.STD
2. UNIT METER MTON
3. INPUT WIDTH 79
4. PAGE LENGTH 84
5. *
6. * FUERZA TON M
7. * LONGITUD M
8. * NUDOS= 7 ELEMENTOS=
9. *
10. * PROYECTO DE ESTRUCTURAS METALICAS
11. *
12. JOINT COORDINATES
13. * CUERDA INFERIOR NUDO INICIAL 0 Y= 0
14. *NUDO X Y Z
15. 1 0 0 0
16. 2 0 0 3
17. 3 0 0 6
18. 4 0 0 9
19. 5 0 1.3 2.25
20. 6 0 1.3 6.75
21. 7 0 2.6 4.5
22. MEMBER INCIDENCE
23. *
24. ****
25. 1 1 2 3
26. 4 1 5
27. 5 2 5
28. 6 2 7
29. 7 3 7
30. 8 3 6
31. 9 4 6
32. 10 5 7
33. 11 6 7
34. ****
35. UNIT CM
36. ***
37. MEMBER PROPERTY AMERICAN
38. *
39. *
40. 1 TO 3 TABLE LD L50306 SP 1.0
41. 4 5 TABLE ST W12X35
42. 6 7 TABLE LD L50306 SP 1.0
43. 8 TO 11 TABLE ST W12X35
44. ****
45. ****
46. MEMBER TRUSS
47. *
48. 1 TO 3 -
49. 4 TO 11

C:\Users\Usuario1\Documents\septimo semestre\staad\ARMA.anl Page 1 of 6


Wednesday, March 29, 2017, 04:56 PM
ARMADURA -- PAGE NO. 2

65. POISSON 0.30 ALL


66. *
67. *APOYOS
68. SUPPORT
69. 1 PINED
70. 4 FIXED BUT FX FZ MX MY MZ
71. ****
72. *CONDICION DE CARGA
73. *
74. LOADING 01 C01=CARGA MUERTA (CM)
75. *
76. * SELFWEIGHT Y -1.000
77. *
78. JOINT LOAD
79. 5 6 FY -10
80. 7 FY -5
81. *
82. LOADING 02 C02=CARGA VIVA MAXIMA
83. *
84. JOINT LOAD
85. 5 6 FY -7.5
86. 7 FY -2.5
87. *
88. LOAD COMBINATION 03 1 CM +1 CVMAX
89. *
90. 1 1 2 1
91. *
92. PERFORM ANALYSIS

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 7 NUMBER OF MEMBERS 11


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 2

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 5/ 5/ 35 DOF


TOTAL PRIMARY LOAD CASES = 2, TOTAL DEGREES OF FREEDOM = 38
TOTAL LOAD COMBINATION CASES = 1 SO FAR.
SIZE OF STIFFNESS MATRIX = 2 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/ 590892.6 MB

*WARNING- ZERO STIFFNESS IN DIRECTION 4 AT JOINT 1 EQN.NO. 1


LOADS APPLIED OR DISTRIBUTED HERE FROM ELEMENTS WILL BE IGNORED.
THIS MAY BE DUE TO ALL MEMBERS AT THIS JOINT BEING RELEASED OR
EFFECTIVELY RELEASED IN THIS DIRECTION.
*WARNING- ZERO STIFFNESS IN DIRECTION 5 AT JOINT 1 EQN.NO. 2
*WARNING- ZERO STIFFNESS IN DIRECTION 6 AT JOINT 1 EQN.NO. 3
*WARNING- ZERO STIFFNESS IN DIRECTION 1 AT JOINT 2 EQN.NO. 4
*WARNING- ZERO STIFFNESS IN DIRECTION 4 AT JOINT 2 EQN.NO. 7
*WARNING- ZERO STIFFNESS IN DIRECTION 5 AT JOINT 2 EQN.NO. 8
*WARNING- ZERO STIFFNESS IN DIRECTION 6 AT JOINT 2 EQN.NO. 9
*WARNING- ZERO STIFFNESS IN DIRECTION 1 AT JOINT 3 EQN.NO. 10
*WARNING- ZERO STIFFNESS IN DIRECTION 4 AT JOINT 3 EQN.NO. 13
*WARNING- ZERO STIFFNESS IN DIRECTION 5 AT JOINT 3 EQN.NO. 14
*WARNING- ZERO STIFFNESS IN DIRECTION 6 AT JOINT 3 EQN.NO. 15
*WARNING- ZERO STIFFNESS IN DIRECTION 1 AT JOINT 4 EQN.NO. 16

**WARNING - THERE WERE MORE THAN 12 DOF WITH ZERO STIFFNESS.


THE FIRST 12 ARE LISTED ABOVE.

C:\Users\Usuario1\Documents\septimo semestre\staad\ARMA.anl Page 2 of 6


Wednesday, March 29, 2017, 04:56 PM
ARMADURA -- PAGE NO. 3

C:\Users\Usuario1\Documents\septimo semestre\staad\ARMA.anl Page 3 of 6


Wednesday, March 29, 2017, 04:56 PM
ARMADURA -- PAGE NO. 4

STAAD.PRO CODE CHECKING - ( AISC-360-10-ASD) v1.4a


********************************************

ALL UNITS ARE - MTON METE (UNLESS OTHERWISE Noted)

MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/


FX MY MZ LOCATION
=======================================================================

1 LD L50306 (AISC SECTIONS)


PASS Eq. H2-1 0.658 3
36.78 T 0.00 0.00 0.00

2 LD L50306 (AISC SECTIONS)


PASS Eq. H2-1 0.387 3
21.63 T 0.00 0.00 0.00

3 LD L50306 (AISC SECTIONS)


PASS Eq. H2-1 0.658 3
36.78 T 0.00 0.00 0.00

4 ST W12X35 (AISC SECTIONS)


PASS Eq. H1-1a 0.532 3
42.48 C 0.00 0.00 0.00

5 ST W12X35 (AISC SECTIONS)


PASS Sec. E1 0.163 3
15.15 C 0.00 0.00 0.00

6 LD L50306 (AISC SECTIONS)


PASS Eq. H2-1 0.271 3
15.15 T 0.00 0.00 0.00

7 LD L50306 (AISC SECTIONS)


PASS Eq. H2-1 0.271 3
15.15 T 0.00 0.00 0.00

8 ST W12X35 (AISC SECTIONS)


PASS Sec. E1 0.163 3
15.15 C 0.00 0.00 0.00

9 ST W12X35 (AISC SECTIONS)


PASS Eq. H1-1a 0.532 3
42.48 C 0.00 0.00 0.00

C:\Users\Usuario1\Documents\septimo semestre\staad\ARMA.anl Page 4 of 6


Wednesday, March 29, 2017, 04:56 PM
ARMADURA -- PAGE NO. 5

STAAD.PRO CODE CHECKING - ( AISC-360-10-ASD) v1.4a


********************************************

ALL UNITS ARE - MTON METE (UNLESS OTHERWISE Noted)

MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/


FX MY MZ LOCATION
=======================================================================

10 ST W12X35 (AISC SECTIONS)


PASS Eq. H1-1a 0.422 3
33.73 C 0.00 0.00 0.00

11 ST W12X35 (AISC SECTIONS)


PASS Eq. H1-1a 0.422 3
33.73 C 0.00 0.00 0.00

103. **
104. STEEL TAKE OFF

C:\Users\Usuario1\Documents\septimo semestre\staad\ARMA.anl Page 5 of 6


Wednesday, March 29, 2017, 04:56 PM
ARMADURA -- PAGE NO. 6

STEEL TAKE-OFF
--------------

PROFILE LENGTH(METE) WEIGHT(MTON)

LD L50306 15.00 0.435


ST W12X35 13.40 0.699
----------------
TOTAL = 1.133

************ END OF DATA FROM INTERNAL STORAGE ************

105. **
106. FINISH

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= MAR 29,2017 TIME= 16:54:41 ****

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************

C:\Users\Usuario1\Documents\septimo semestre\staad\ARMA.anl Page 6 of 6