Beruflich Dokumente
Kultur Dokumente
Rosslares VeritraxTM Networked Access Control System: 255 panels (510 Doors)
Control. System of networked HW Controllers & Client/Server Enterprise PC Software.
# Holiday Dates: 64
Compatible Reader Protocols: Clock & Data, or Wiegand 26 Bits
Anti-Passback (Hard/Soft) YES Out 2A COM. Out 1A COM.
Input 2A Out 2A N.O Out 1A N.O
Input 1A
Real Anti-Passback: Valid for Two Readers on one ACU Output 2A Out 2A N.C Out 1A N.C Output 1A
Timed Anti-Passback: Valid on Each Reader (0 to 250 min) In 2A < - > In 1A < - >
In 2A <+> In 1A <+>
Global Anti-Passback: YES, Valid on all panels on all networks.
Programmable Auto Relock: YES, Based on Door Monitor or Timer
Extended Door Unlock Time: YES, Based on User Definition (Handicapped..)
Man Trap: YES, Based on Door Monitor to Enable Reader
First Person Delay: YES, on Automatic Door Unlock
RS485-
Output Activation: Timed, Toggled, or Input Follower RS232- Communications
INPUT
System Alarms: System registers various alarms. Communications Direct Wiring
POWER
Direct Wiring
Multiple Facility Codes: 4-max
Inputs: 4 Inputs - Single Door Configuration: Figure 4. AC-215 Main Controller Board
1) REX, 2) Monitor, 3) Tamper, 4) General Aux
4 Inputs - Two Door Configuration:
1) REX1 2) Monitor1 3) REX2 4) Monitor2 ELECTRICAL DATA:
Relay Outputs: 4 Outputs - Single Door Configuration: ACU Power Supply Voltage: 12V DC Regulated
1) Lock, 2) Alarm, 3) Aux 4) General Aux - From OEM Power Supply PS-14
4 Outputs - Two Door Configuration: ACU Power Supply Max Current: 500 mA input Current Limited
1) Lock1, 2) Alarm1, 3) Lock2 4) Alarm2 - From OEM Power Supply PS-14
ACU Maximum Input Current: Standby Load: 125 mA @ 12V DC
COMMUNICATIONS DATA: Max Load: 325 mA @ 12V DC
ACU Communications Method: RS-232 / RS-485 Half Duplex Max Current for PROX Readers: 150 mA@ 12V DC for Each Prox Reader
ACU Communications Data Rate: 57,600 Bits Per Second Max Current for Mag Stripe Readers: 150 mA@ 12V DC for Each Prox Reader
Dial-Up Remote Modem Support: YES, Supports Remote Modem Subnet (OEM MD-N33) Max Current for Keypad: 150 mA@ 12V DC for Each Keypad
TCP/IP Remote LAN Support: YES, Supports Remote TCP/IP Subnet (OEM MD-N32) Supports Heated Readers: YES, 12 V DC @150 mA
Remote Firmware Upgrade Support: YES, ACU Firmware may be changed by PC: 64 K with Maximum Current for Lock Strike: ACU Relay Supports up to 30V 5A
Bootstrap Loader and FLASH memory architecture.
RS-485 Network Bus Distance (Max): 1200 m Belden Shielded Pairs ELECTRICAL DATA POWER PCB << PS-14 >>:
Requires a Class 2 Transformer: Transformer Input 220 / 110 VAC
50/60 Hz to 16 Volt AC Output
INDICATIONS & MMI DATA:
Unregulated AC Input Power: 16 Volt AC (From Transformer)
ACU LED Visual Indicators: 8 - LEDs
Regulated DC Power Output: 12 Volt DC with 500 mA current Limit.
1) Data Rx
Backup Rechargeable Power: Yes, Supports 12V Lead Acid (SLA-Type)
2) Data Tx
Rechargeable Cell with on-board Charger
3) Relay Output 1
4) Relay Output 2 (PS-14 ) Auxiliary Power Output: PS-14 has 12V/2A for door strike and/or
5) Relay Output 1A Auxiliary output
6) Relay Output 2A Low Battery Status Monitoring: By Open Collector Output
7) Reader 1 Mode
8) Reader 2 Mode AC Power Loss Monitoring: By Open Collector Output