P R OT E C T I O N

IEC 61850 STANDARD


Interoperability for Advanced
Protection and Control
Applications

IEC 61850 is the new international standard for communication in


substations. It enables integration of all protection, control,
measurement and monitoring functions within a substation, and
additionally provides the means for high-speed substation
protection applications, interlocking and intertripping.
It combines the convenience of Ethernet with the performance and
security which is essential in substations today.

As a result of 10 years of active


HMI participation of several AREVA experts in
IEC and UCA working groups developing
SCADA this new substation communication
Gateway
technology, and following successful
interoperability demonstrations at
CIGRE 2004 and many other events,
AREVA T&D Automation has been busy
adapting its Protection (MiCOM P range)
Fast Ethernet IEC 61850 and Control (MiCOM C range) devices to
support this new international standard.
C264 C264C
The protection relays integrate with the
PACiS substation control systems over the
MiCOM relays I/O MiCOM relays IEC 61850 8-1 Substation Bus and at the
RS 485 RS 485
same time can interface with our own or
other vendors Merging Units over the
IEC 61850 9-2 Process Bus, thus
completing AREVA T&D Automation's offer
MiCOM relays MiCOM relays
of a full IEC 61850 solution for your
substation.

AREVA provides solutions that allow the migration from conventional


or different legacy substation automation systems to IEC 61850
based SAS. Relays which have already been delivered with UCA2 on
Ethernet can be easily upgraded to IEC 61850, while relays that
support other communication protocols can be integrated using
"proxy" servers.

Customer benefits
Cost effective solution
due to reduced inter-wiring
Flexible programming
allowing relays and new
protection functions to be MiCOM and PACiS
added without affecting
physical wiring working in harmony
No external protocol
converters are required

AREVA T&D
IEC 61850 OFFERS THE FOLLOWING > Uniformity
BENEFITS TO UTILITIES AND One protocol is all that is needed in the substation.
INDUSTRIAL USERS: Costly gateways and split path communications are
thus avoided.
> High Speed Data Exchange Peer-to-peer messages, control commands,
Ethernet links operating at 100 Mbit/s exchange polled disturbance files transfer or event driven reports are
data and commands between devices at a far faster interleaved on a single Substation Bus network.
rate than traditional serial/ fieldbus protocols. Clients Multiple clients can be integrated, allowing authorised
(master stations) can perform supervisory control with operators and engineers to interrogate and control the
negligible delay. substation IEDs.
Client-Server replaces Master-Slave communications
and allows simultaneous access of several clients to
the same server. > Simplified Engineering Process
The Substation Configuration Language defined in the
standard represents a leap in the engineering process
> Peer-to-Peer Communication related to any type of substation automation
Since all Intelligent Electronic Devices (IEDs) within application.
the substation can communicate with each other using It is based on a standardized abstract object model
reliable high-speed peer-to-peer communications, that allows the development of substation specification,
extensive hardwiring in equipment bays is eliminated configuration, analysis and testing tools
and the cost of implementing advanced distributed
protection and control schemes is significantly

AUTOMATION-L3-IEC61850-DS-01.06-1293-GB - - AREVA - 2005. AREVA, the AREVA logo and any alternative version thereof are trademarks and service marks of AREVA. MiCOM is a registered
trademark of AREVA. All trade names or trademarks mentioned herein whether registered or not, are the property of their owners. - 389191982 RCS PARIS - Printed in France - SONOVISION-ITEP
reduced. Generic Substation Event (GSE) messages
can be used for interlocking, disturbance recording MiCOM CAPABILITY
cross-triggering, breaker failure protection tripping,
The IEC 61850 interface of the MiCOM P range relays
directional comparison bus protection and many other
initially provides the following capabilities:
advanced applications.

> Object model covering IED measurements,


> Process Bus Interface protection, control and recording functions
Analog interface units (or Merging Units) located in the > GSE : High-speed Peer-to-Peer Communication
substation yard interface with conventional or non-
> Read access to measurements and statuses
conventional instrument transformers and send the
sampled current and voltage values over fiber, thus > Generation of reports on changes of measurements.
significantly reducing (actually eliminating) the copper Measurement reports can be generated when user
wires between the substation primary equipment and defined criteria have been met. This will usually be in
the protection, control and measuring devices. the form of a setting such as percentage change of a
measurement (deadband).
> Direct Control or Select Before Operate (SBO) with
> Standard Bay Schemes
normal or enhanced security
Economies of scale will result where standard
protection and control bay schemes are engineered. > Generation of reports on changes of status. Status
The exact customising of the scheme to suit the reports can be generated by protection events when
application is achieved in software, using GSE logic. user-defined reporting criteria have been met.
> SNTP Time Synchronisation

> True Interoperability > Disturbance Record Extraction


The self-descriptive nature of IEC 61850-compatible
IEDs means that system integration and
The MiCOM S1 engineering tool allows configuration
commissioning is easier.
and setting transfers of IEC 61850- enabled
Standardised data classes and services mean
MiCOM IEDs via traditional communication links
IEC 61850-enabled MiCOM IEDs can operate
or via an Ethernet connection, whether or not an
seamlessly in multi-vendor environments.
IEC 61850-based control system is present.

Our policy is one of continuous development. Accordingly


AREVA T&D Worldwide Contact Centre: the design of our products may change at any time. Whilst
http://www.areva-td.com/contactcentre/ every effort is made to produce up to date literature, this
brochure should only be regarded as a guide and is
Tel.: +44 (0) 1785 250 070 intended for information purposes only. Its contents do not
constitute an offer for sale or advise on the application of
any product referred to in it. We cannot be held responsible
www.areva-td.com for any reliance on any decisions taken on its contents
without specific advice.
www.areva-td.com/protectionrelays

Das könnte Ihnen auch gefallen