PILE DESIGN REPORT

Project : PILE Design Site Name : Wattang Sawitto


Client : PT. INTI BANGUN SEJAHTERA Site ID : ZMKS_0061
Deep Footing Design Based on ACI 318-05
3.2 CHECK OF BEARING

3.2.1 PILE CAPACITY

DIAMETER OF PILE Dp = 40 cm
DEPTH OF PILE Lp = 10.5 m
CONCRETE STRENGTH OF PILE f c' p = 18.675 Mpa
MODULUS ELASTICITY OF PILE Ep = 20311 Mpa

Qu
Qh
Ha
Dp
Ks-S1 qall-gross
Lp Qs

4d Ks-S2
qc average
4d qall-p

Qp

ULTIMIT PILE CAPACITY (Qu) = Qs + Qs - W


ULTIMIT END BEARING CAPACITY (Qp) = Ap.qc av
ULTIMIT SIDE FRICTION CAPACITY (Qs) = TF . Pp
ALLOWABLE PILE CAPACITY (Qall-p) = (Qs/SF1) + (Qs/SF2)
ALLOW. TENSION CAPACITY OF PILE (Tu) = (TF . Pp)/5 + W
ALLOW. BEARING CAPACITY OF PILECAP = qc/15
ALLOWABLE HORIZONTAL CAPACITY (Ha) = ((k.D)/b) . a

Qc AVERAGE qc av 106.261 kg/cm2


TOTAL FRCITION TF 1180.000 kg/cm
SAFETY FACTOR FOR END BEARING SF1 3.000 -
SAFETY FACTOR FOR SIDE FRCITION SF2 5.000 -
SECTION AREA OF PILE Ap 1256.637 cm2
PERIMETER OF PILE Pp 125.664 cm
ULTIMIT END BEARING CAPACITY Qp 133530.888 kg
ULTIMIT SIDE FRICTION CAPACITY Qs 148283.173 kg
SELF WEIGHT OF PILE W 3166.725 kg
ALLOWABLE BEARING PILE CAPACITY Qall-p 71000.205 kg
5540.745 kN/m2
SUBGRADE MODULUS OF PILE Ks -S2 664889.458 kN/m3
ALLOWABLE LATERAL CAPACITY Ha 37.440 kN
ALLOW. TENSION CAPACITY OF PILE Tu 291.135 kN