Sie sind auf Seite 1von 16

226 Com m ando

wiring devices | in g r e s s p ro te c te d www.m k electric.co.u k

ra nge introdu ction fea tu re b enefits

Com m a ndo offers a com p reh ensive ra nge of indu stria l R e lia b ilit y
p lu gs, connectors, sock et ou tlets, a p p lia nce inlets, Com b i F ea tu res lik e th e ca lib ra ted conta ct sleeves with sta inless steel sp rings,
b ra ss screws in b ra ss conta cts ,a nd th e dou b le ea rth ing screws a ll
a nd M odu la r-Com b i u nits.
m ea n th a t th is p lu g or sock et will p erform b etter a nd longer in difficu lt
conditions
T h e Com m a ndo ra nge is designed to m eet a ll releva nt
E u rop ea n a nd B ritish S ta nda rds, wh ilst offering a n ex cellent E rg o n o m ic d e s ig n
ch oice of ingress p rotected ra tings. T h e Com m a ndo A ll edges a nd corners a re rou nded to rem ove sh a rp edges. Ca b le
ra nge offers rem a rk a b le im p a ct strength b y wa y of its p rotection is im p roved. N ew design offers a b etter a nd m ore com forta b le
P B T (P oly b u ty lene T erep h th a la te) or N y lon (P oly a m ide grip for connection / disconnection

P A ) insu la ted or a lu m iniu m h ou sing* . O u tsta nding


C a b le p ro t e c t io n
tem p era tu re p erform a nce a nd good resista nce to m ost
T h e u nified sea l a nd ca b le p rotector form s a convex dom e th a t p revents
ch em ica ls m a k e it idea l for th e m ost a rdu ou s a p p lica tions. th e p lu g from fa stening on ob jects or collecting deb ris wh en dra gged
Conta ct p ins a nd sleeves a re of solid b ra ss with sta inless
steel sp rings to k eep conta cts free of dirt a nd to ensu re E a s y w irin g
consta nt conta ct p ressu re. A ll screws a re b a ck ed ou t a nd reta ined. Conta ct ca rrier m a rk ed front a nd
b a ck for ea sy a nd correct wiring. H inged ca b le cla m p a nd twin conta ct
ea rth screws

O u t s t a n d in g T e m p e ra t u re P e rfo rm a n c e
S u ccessfu l op era tion gu a ra nteed b etween -2 5 oC a nd 5 5 oC

* 1 6 A a n d 3 2 A IP 4 4 p lu g , c o n n e c to r a n d s o c k e t o u tle t
p ro d u c ts h a v e h o u s in g s m a n u fa c tu re d fro m P A
Commando 227

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

ROB U S T & TH U M B G RIP


ERG ON OM IC
S U PERIOR G RIP
D ES IG N
CA L IB RA TED
CON TA CTS
F L EX IB L E &
CON V EX CA B L E
EN TRY

F L IP-A -S ID E
CA B L E CL A M P
S EL F -CL EA N IN G
TW IS T & L OCK
CON TA CTS
H OU S IN G

F IT IT... F ORG ET IT
M ost reliab le industrial plug and socket range.

T W IS T IT W IR E IT PU S H IT
S plit housing w ith tw ist-and-lock closure Q uick and easy w iring. All screw s face
Push the plug and socket together for a
needs no tool, and means a faster and the user and are b acked out and
tight smooth contact. T he earth contact
safe assemb ly . A tool is needed to retained. C ontact carrier marked front
makes first and b reaks last.
disassemb le it. and b ack for easy and correct w iring.
H inged cab le clamp and tw in contact
earth screw s.
228 Commando

wiring devices | ingress protected www.mkelectric.co.uk

Plu g s C o n n e c to rs S o c k e t O u tle ts
AN GL ED STRAIGHT
IP 44
S PL A S H PR O O F
100 - 130V SURF ACE SURF ACE L O O P IN PAN EL MO UN TIN G
50 - 60 H z

Am p s Pin . E a rth
C o n fig - H our
u ra tio n Po s

16 2P+ E 4 K9000 YEL K91 00 YEL K92 00 YEL K1 3 2 00 YEL K94 00 YEL
16 3 P+ E 4 K9005 YEL K91 05 YEL K92 05 YEL K94 05 YEL
16 3 P+ N+ E 4 K901 3 YEL K91 13 YEL K92 13 YEL K94 13 YEL
32 2P+ E 4 K903 2 YEL K91 32 YEL K92 32 YEL K1 3 2 3 2 YEL K94 32 YEL
32 3 P+ E 4 K903 5 YEL K91 35 YEL K92 35 YEL K94 35 YEL
32 3 P+ N+ E 4 K904 3 YEL K91 42 YEL K92 39 YEL

F itte d w ith F itte d w ith 16A T o p c o n d u it (M20 ) o r S u ita b le fo r to p e n try All fla n g e s h a v e th e s a m e
c a b le e n try g la n d . c a b le e n try g la n d . re a r c a b le e n try , c o m p le te 2 x 25 . fix in g c e n tre s a n d o u ts id e
BS EN 60309 w ith b la n k in g p lu g . F itte d w ith te rm in a ls d im e n s io n s to a s s is t p a n e l
BS EN 60309 b u ild e rs .
3 2 A T o p c o n d u it (M25 ) o r fo r Lo o p In 2 x 1 0 m m 2.
re a r c a b le e n try , c o m p le te BS EN 60309 Min im is e d fla n g e o p tio n
w ith b la n k in g p lu g . a v a ila b le (s e e p a g e 24 0 ).
BS EN 60309 BS EN 60309

Plu g s C o n n e c to rs S o c k e t O u tle ts
IP 6 7
AN GL ED
W A T ER T IG H T
100 - 130V
50 - 60 H z SURF ACE SURF ACE L O O P IN PAN EL MO UN TIN G

Am p s Pin . E a rth
C o n fig - H our
u ra tio n Po s

16 2P+ E 4 K902 3 YEL K91 2 3 YEL K91 93 YEL K1 3 02 3 YEL K98 02 YEL
32 2P+ E 4 K905 3 YEL K91 5 5 YEL K97 6 1 YEL K1 3 05 3 YEL K98 6 5 YEL
63 2P+ E 4 K92 94 YEL K98 5 5 YEL

S u ita b le fo r fle x ib le c a b le o n ly . S u ita b le fo r fle x ib le c a b le o n ly . S u ita b le fo r to p e n try 2 x 25 S u ita b le fo r to p e n try 2 x 25 All fla n g e s h a v e th e s a m e
6 3 A:w ith e x te rn a l c la m p . 6 3 A:w ith e x te rn a l c la m p . o r b o tto m e n try 2 x 20 . fix in g c e n tre s a n d o u ts id e
BS EN 60309 d im e n s io n s to a s s is t p a n e l
BS EN 60309 BS EN 60309 W ill a c c e p t F L1 3 fla n g e a t to p . b u ild e rs .
BS EN 60309 BS EN 60309
S o c k e t O u tle ts 6 3 A p lu g s a n d in le ts in c lu d e p ilo t p in s .
IP 44 TWIN 6 3 A c o n n e c to rs a n d s o c k e ts w ith p ilo t s le e v e s a re a v a ila b le to s p e c ia l o rd e r.
S PL A S H PR O O F SURF ACE All p ro d u c ts a re a v a ila b le in m in im u m o rd e r q u a n tity o f o n e e x c e p t K9 0 0 0 a n d K9 1 0 0
100 -130V Pre w ire d Unwired
(w h ic h h a v e a m in im u m o rd e r q u a n tity o f 1 0 ).
50 -60 H z K 1 3 1 43 Y EL K 1 3 0 43 Y EL
Ph o to g ra p h s fe a tu re th e m o s t re p re s e n ta tiv e p ro d u c ts .
De s ig n c h a n g e s m a y o c c u r (o v e r d iffe re n t c u rre n t ra tin g s ) fro m o n e p ro d u c t to a n o th e r.
16 Am ps
2 P+ E S u ita b le fo r to p e n try 2 x 25 2 x 3 8
B o tto m e n try 3 x 4 7 .5 m m
BS EN 60309
Commando 229

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

Socket Outlets Switchsocket Outlets Applia nce


ANGLED ANGLED ANGLED Inlets
INTERLOCK ED ANGLED
PANEL MOUNTING SURFACE SURFACE SURFACE SURFACE SURFACE

K9767 YEL K9912 YEL K13600 YEL K9609 YEL K9700 YEL
K9600 YEL
K9606 YEL K9709 YEL
K9769 YEL K13632 YEL K9642 YEL K9732 YEL
K9632 YEL
K9638 YEL

16/32A new range has With 2 x M20 threaded Switch can be locked in open Suitable for top entry With 25mm knockout 16A Top conduit (M20) or
different fixing centres to conduit entries and 1 x or closed position. 2 x 25. at top. rear cable entry, complete
old range. 18mm. knockouts in both with blanking plug.
top and bottom. BS EN 60309 Switch can be locked in open Will also accept FL13 flange
Old range is available for position. Or closed position (top). 32A Top conduit (M25) or
limited period. See technical Supplied with blanking by removing the tab. rear cable entry, complete
plugs/cable entry. Bottom entry M25.
section for details. BS EN 60309 with blanking plug.
BS EN 60309 BS EN 60309
BS EN 60309 BS EN 60309

Switchsocket Switchsocket Applia nce


Outlets Outlets Inlet
ANGLED Pa nels
INTERLOCK ED
SURFACE SURFACE

K13623 YEL K9780 YEL


K13653 YEL K9784 YEL
K9356 YEL K9788 YEL

With 32mm knockouts top Suitable for top entry BS EN 60309 BS EN 60309
and bottom. 2 x 25.
Will also accept FL13 flange Switch can be locked in open
(top). position. In closed position by
Switch can be locked in open removing the tab.
position. In closed position by BS EN 60309
removing the tab.
BS EN 60309

See pa ge 240 for d eta ils of spa re or a lterna tiv e


FL ty pe fla nges.
230 Commando

wiring devices | ingress protected www.mkelectric.co.uk

Plugs Connectors Socket Outlets


IP 44 ANGLED STRAIGHT
SPLASHPROOF PANEL
200 - 250V SURFACE SURFACE-LOOP IN MOUNTING
50 - 60 Hz

Amps Pin. Earth


Config- Hour
uration Pos

16 2P+E 6 K9001 BLU K9101 BLU K9201 BLU K13201 BLU K9401 BLU
16 3P+E 9 K9006 BLU K9106 BLU K9206 BLU K9406 BLU
16 3P+N+E 9 K9014 BLU K9114 BLU K9214 BLU K9414 BLU
32 2P+E 6 K9033 BLU K9133 BLU K9233 BLU K13233 BLU K9433 BLU
32 3P+E 9 K9036 BLU K9136 BLU K9236 BLU
32 3P+N+E 9 K9044 BLU K9143 BLU K9240 BLU K9444 BLU
63 2P+E 6 K9063 BLU K9172 BLU K9274 BLU K9472 BLU
63 3P+E 9 K9065 BLU K9164 BLU K9264 BLU

16A/32A Fitted with cable 16A/32A Fitted with cable 16A Top conduit (M20) or Suitable for top entry 16/32A All flanges have
entry gland. entry gland. rear cable entry, complete 2 x 25. the same fixing centres and
with blanking plug. Fitted with terminals outside dimensions to assist
63A Fitted with cable entry 63A Fitted with cable entry panel builders.
gland. gland. 32A Top conduit (M25) or for Loop In 2 x 10mm2.
rear cable entry, complete BS EN 60309 Minimised flange option
Thread siz e M48. Thread siz e M48. with blanking plug. available (see page 240).
BS EN 60309 BS EN 60309 63A Top conduit (M32) or BS EN 60309
rear cable entry, complete
with blanking plug.
BS EN 60309

Plugs Connectors Socket Outlets


IP 67 ANGLED STRAIGHT
WATERTIGHT
200 - 250V SURFACE SURFACE LOOP IN PANEL MOUNTING
50 - 60 Hz

Amps Pin. Earth


Config- Hour
uration Pos
16 2P+E 6 K9024 BLU K9124 BLU K9194 BLU K13024 BLU
32 2P+E 6 K9054 BLU K9156 BLU K9762 BLU K13054 BLU
63 2P+E 6 K9298 BLU K9856 BLU K9857 BLU K9828 BLU
63 3P+E 9
125 2P+E 6 K9099 BLU K9189 BLU K9190 BLU K9483 BLU

Suitable for flexible cable only Suitable for flexible cable only Suitable for top entry 2 x 25 16/32A Suitable for top entry 2 x 25
63A and 125A. With external 63A and 125A. With external or bottom entry 2 x 20.
clamp. clamp. 125A 2 x 23/47mm knockouts top and
Will accept FL13 flange at top. bottom.
BS EN 60309 BS EN 60309
BS EN 60309 BS EN 60309

63/125A plugs and inlets include pilot pins.


Socket Outlets 63A connectors and sockets with pilot sleeves are available to special
IP 44 order.
SPLASHPROOF ANGLED TWIN 125A Switchsocket interlocked outlets with pilot sleeves are available
to special order.
200 - 250V All products are available in minimum order quantity of one except
50 - 60 Hz SURFACE Suitable for top entry K9001 and K9101 which have minimum order quantities of 10.
2 x 25 / 2 x 38
16 Amps Prewired U nwired Bottom entry 3 x 47.5mm Photographs feature the most representative products.
Design changes may occur (over different current ratings) from one
2P + E K13144 B LU K13044 B LU BS EN 60309 product to another.
Commando 231

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

Socket Outlets Switchsocket Outlets Appliance


ANGLED ANGLED Inlets
PANEL INTERLOCKED ANGLED
MOUNTING SURFACE SURFACE SURFACE SURFACE SURFACE

K9771 BLU K9913 BLU K13601 BLU K9610 BLU K9701 BLU
K9772 BLU K9919 BLU K9601 BLU
K9773 BLU K9607 BLU K9710 BLU
K9774 BLU K13633 BLU K9643 BLU K9733 BLU
K9633 BLU
K9776 BLU K9639 BLU K9740 BLU
K9544 BLU K9306 BLU K9775 BLU
K9664 BLU K9311 BLU

16/32A new range has With 2 x M20 threaded Switch can be locked in open Suitable for top entry 16/32A With 25mm knockout 16A Top conduit (M20) or
different fixing centres to old conduit entries and 1 x 18mm or closed position 2 x 25. at top. rear cable entry, complete
range. knockout in both top and BS EN 60309 Will also accept FL13 flange with blanking plug.
bottom. Switch can be locked in
open position. Or closed (top).
Old range is available for Bottom entry M25. 32A Top conduit (M25) or
limited period. See technical Supplied with blanking plugs/ position by removing the rear cable entry, complete
section for details. cable entry. tab. BS EN 60309 with blanking plug.
BS EN 60309 K9919 socket is straight. BS EN 60309 63A Top conduit (M32) or
K9913 socket is angled. rear cable entry, complete
with blanking plug.
BS EN 60309
BS EN 60309

Socket Outlets Switchsocket Outlets Appliance Inlets Appliance


ANGLED ANGLED ANGLED Inlet Panels
INTERLOCKED
PANEL MOUNTING SURFACE SURFACE SURFACE SURFACE

K9803 BLU K13624 BLU K9324 BLU K9781 BLU


K9866 BLU K13654 BLU K9369 BLU K9785 BLU
K9825 BLU K9355 BLU K9826 BLU K9789 BLU*

K9688 BLU K9883 BLU K9792 BLU*

16/32A All flanges have 16/32A Suitable for top 16/32A With 29mm 2 x 23/47mm knockouts top Will accept FL13 flanges top *Note: 63 and 125A versions
the same fixing centres and entry knockout at top Will also and bottom. and bottom. do not include a flange (See
outside dimensions to assist 2 x 25. accept FL13 flange (top). page 229 for photograph).
BS EN 60309 BS EN 60309
panel builders. BS EN 60309
125 A 2 x 23/47mm Bottom entry M25.
BS EN 60309 knockouts top and bottom.
63A With 32mm knockouts
Switch can be locked in open top and bottom.
position. In closed position Will accept FL13 flange top
by removing the tab. and bottom.
BS EN 60309 BS EN 60309

See page 240 for details of spare or alternative FL type flanges.


232 Commando

wiring devices | ingress protected www.mkelectric.co.uk

Plugs Connectors Socket Outlets


IP 44 ANGLED STRAIGHT
SPLASHPROOF
38 0 - 415V SURFACE SURFACE LOOP IN PANEL MOUNTING
50 - 60 Hz

Amps Pin. Earth


Config- Hour
uration Pos

16 2P+E 9 K9002 RED K9102 RED K9202 RED


16 3P+E 6 K9007 RED K9107 RED K9207 RED K13207 RED K9407 RED
16 3P+N+E 6 K9015 RED K9115 RED K9215 RED K13215 RED K9415 RED
32 3P+E 6 K9037 RED K9137 RED K9237 RED K13237 RED K9437 RED
32 3P+N+E 6 K9045 RED K9144 RED K9241 RED K13241 RED K9445 RED
63 3P+E 6 K9066 RED K9165 RED K9265 RED K9465 RED
63 3P+N+E 6 K9071 RED K9170 RED K9269 RED K9470 RED

16A/32A Fitted with cable 16A/32A Fitted with cable 16A Top conduit (M20) or Suitable for top entry 16/32A All flanges have
entry gland. entry gland. rear cable entry, complete 2 x 25. the same fixing centres and
with blanking plug. Fitted with terminals outside dimensions to assist
63A Fitted with cable entry 63A Fitted with cable entry panel builders.
gland. gland. 32A Top conduit (M25) or for Loop In 2 x 10mm2.
rear cable entry, complete Minimised flange option
Thread size M48. Thread size M48. with blanking plug. available (see page 240).
63A Top conduit (M32) or
rear cable entry, complete
with blanking plug.

Plugs Connectors Socket Outlets


IP 67 ANGLED
WATERTIGHT STRAIGHT
38 0 - 415V
50 - 60 Hz SURFACE SURFACE LOOP IN PANEL MOUNTING

Amps Pin. Earth


Config- Hour
uration Pos

16 3P+E 6 K9025 RED K9125 RED K9763 RED K13025 RED


16 3P+N+E 6 K9026 RED K9126 RED K9764 RED K13026 RED
32 3P+E 6 K9055 RED K9157 RED K9765 RED K13055 RED
32 3P+N+E 6 K9056 RED K9158 RED K9766 RED K13056 RED
63 3P+E 6 K9282 RED K9842 RED K9858 RED K9812 RED
63 3P+N+E 6 K9292 RED K9852 RED K9859 RED K9822 RED
125 3P+E 6 K9092 RED K9182 RED K9191 RED K9481 RED
125 3P+N+E 6 K9097 RED K9187 RED K9192 RED K9482 RED

Suitable for flexible cable only. Suitable for flexible cable only. 2 x 29/37mm knockouts 16/32A Fitted with terminals
63A and 125A have external 63A and 125A have external (top), 1 x 29 and 1 x 23 for Loop In. Suitable for top
clamp. clamp. knockout (bottom). entry 2 x 25.
Will accept FL13 flanges top 125A Fitted with terminals
63/125A plugs and inlets include pilot pins. and bottom.
63A connectors and sockets with pilot sleeves are available to for Loop In. 2 x 23/47mm
special order. knockouts top and bottom
for looping 2 x 10mm2.
125A Switchsocket interlocked outlets include pilot sleeves are
available to special order.
All products are available in minimum order quantity of one.
Photographs feature the most representative products.
Design changes may occur (over different current ratings) from
one product to another.
Commando 233

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

Socket Outlets Switchsocket Switchsocket Outlets Appliance


ANGLED Outlets ANGLED Inlets
INTERLOCKED ANGLED
PANEL MOUNTING SURFACE SURFACE SURFACE SURFACE SURFACE

K9777 RED K9914 RED


K9778 RED K9920 RED K9602 RED K13607 RED K9611 RED K9706 RED
K9779 RED K9608 RED K13615 RED K9612 RED K9711 RED
K9751 RED K9634 RED K13637 RED K9644 RED K9736 RED
K9752 RED K9640 RED K13641 RED K9645 RED K9741 RED
K9565 RED K9665 RED K9312 RED
K9570 RED K9670 RED K9322 RED K9768 RED

16/32A new range has With 2 x M20 threaded Switch can be locked in open Suitable for top entry 16/32A 16A Top conduit (M20) or
different fixing centres to conduit entries and 1 x or closed position. 2 x 25. With 25mm knockout at top. rear cable entry, complete
old range. 18mm knockouts in both top Switch can be locked in open Will also accept FL13 flange with blanking plug.
and bottom. position. In closed position top.
Old range is available for 32A Top conduit (M25) or
limited period. See technical Supplied with blanking by removing the tab. Bottom entry M25. rear cable entry, complete
section for details. plugs/cable entry. with blanking plug.
K9914 is angled. 63A Top conduit (M32) or
rear cable entry, complete
K9920 is straight. with blanking plug.

Socket Outlets Switchsocket Outlets Appliance Inlets Appliance


ANGLED
ANGLED ANGLED INTERLOCKED Inlet Panels

PANEL MOUNTING SURFACE SURFACE SURFACE SURFACE

K9807 RED K13625 RED K9327 RED K9782 RED


K9815 RED K13626 RED K9330 RED K9783 RED
K9870 RED K13655 RED K9359 RED K9786 RED
K9873 RED K13656 RED K9362 RED K9787 RED
K9582 RED K9342 RED K9829 RED K9790 RED*
K9592 RED K9352 RED K9827 RED K9791 RED*
K9691 RED
K9694 RED K9884 RED K9793 RED*

16/32A All flanges have 16/32A Suitable for top 16/32A With 29mm knockout 2 x 23/47mm knockouts top 1.x M40/M32 *Note: 63 and 125A versions
the same fixing centres and entry at top will also accept FL13 and bottom. 2 x M20 top do not include a flange (See
outside dimensions to assist 2 x 25. flange at top. Bottom. Conduit page 229 for photograph).
entry M25. 2 x M40/M32
panel builders. 125A 2 x 23/47mm 63A 1 x M20 bottom
knockouts top and bottom. With 32mm knockouts top
and bottom. Will accept FL13 Will accept FL13 flanges top
Switch can be locked in and bottom.
open position. In closed flange top and bottom.
position by removing the
tab.
See page 240 for details of spare or alternative FL type flanges.
234 Commando

wiring devices | ingress protected www.mkelectric.co.uk

Plugs Connectors Socket Outlet


IP 44 ANGLED STRAIGHT ANGLED
SPLASHPROOF SURFACE PANEL MOUNTING PANEL MOUNTING
440 - 460V
60 Hz
SUITAB L E F O R
M AR IN E
IN STAL L ATIO N S
Amps Pin. Earth
Config- Hour
uration Pos

16 3P+E 11 K9008 RED K9108 RED K9208 RED K9753 RED


16 3P+N+E 11 K9016 RED K9116 RED K9216 RED K9416 RED K9754 RED
32 3P+E 11 K9038 RED K9138 RED K9755 RED
32 3P+N+E 11 K9046 RED K9145 RED K9242 RED K9446 RED
Fitted with cable entry gland. Fitted with cable entry gland. 16A Top conduit (M20) or All flanges have the same 16/32A new range has
rear cable entry, complete fixing centres and outside different fixing centres to
with blanking plug. dimensions to assist panel old range.
32A Top conduit (M25) or builders.
rear cable entry, complete Minimised flange option Old range is available for
with blanking plug. available (see page 240). limited period. See technical
Switchsocket section for details.
IP 44
SPLASHPROOF Outlets
440 - 460V Interlocked
60 Hz SURFACE

SUITAB L E F O R
M AR IN E
IN STAL L ATIO N S
Amps Pin. Earth
Config- Hour
uration Pos

16 3P+E 11 K9603 RED


16 3P+N+E 11
32 3P+E 11 K9635 RED
32 3P+N+E 11 K9641 RED

Switch can be locked in open


or closed position.

Plugs Connectors Socket Outlets Switchsocket Outlets


IP 67 ANGLED ANGLED INTERLOCKED
WATERTIGHT
SURFACE SURFACE SURFACE
440 - 460V
60 Hz
SUITAB L E F O R
M AR IN E
IN STAL L ATIO N S
Amps Pin. Earth
Config- Hour
uration Pos

63 3P+E 11 K9283 RED K9843 RED K9343 RED


63 3P+N+E 11 K9293 RED K9853 RED K9353 RED
125 3P+E 11 K9093 RED K9183 RED K9195 RED K9692 RED
Suitable for flexible cable only. Suitable for flexible cable only. 2 x 23/47mm knockouts top 2 x 23/47mm knockouts top With 32mm knockouts top
With external clamp. With external clamp. and bottom. and bottom. and bottom.
Switch can be locked in open Will accept FL13 flange top
63/125A plugs and inlets include pilot pins. All products are available in minimum order quantity of one. position. In closed position and bottom.
63A connectors and sockets with pilot sleeves are available to Photographs feature the most representative products. by removing the tab.
special order Small design changes may occur (over different current ratings)
125A Switchsocket interlocked outlets with pilot sleeves are from one product to another.
available to special order.
Commando 235

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

Plugs Connectors Socket Outlets


IP 44 ANGLED
SPLASHPROOF SURFACE
480 - 500V
50 - 60 Hz

Amps Pin. Earth


Config- Hour
uration Pos

16 3P+E 7 K9009 BLK K9109 BLK K9209 BLK


32 3P+E 7 K9039 BLK K9139 BLK K9238 BLK

Fitted with cable entry gland. Fitted with cable entry gland. 16A Top conduit (M20) or
rear cable entry, complete
with blanking plug.

Switch Socket Appliance Inlets 32A Top conduit (M25) or


rear cable entry, complete
IP 44 Outlets ANGLED with blanking plug.
SPLASHPROOF ANGLED
480 - 500V INTERLOCKED SURFACE
50 - 60 Hz SURFACE

Amps Pin. Earth


Config- Hour
uration Pos

16 3P+E 7 K9604 BLK K9707 BLK


32 3P+E 7 K9636 BLK K9737 BLK

Switch can be locked in open 16A Top conduit (M20) or rear cable entry, complete with
or closed position. blanking plug.
32A Top conduit (M25) or rear cable entry, complete with
blanking plug.

Plugs Connectors Switchsocket Outlets


IP 67 ANGLED
WATERTIGHT INTERLOCKED
480 - 500V SURFACE
50 - 60 Hz
63/125A plugs and inlets
include pilot pins.
63A connectors and sockets
with pilot sleeves are
available to special order.
All products are available in
a minimum order quantity
of one.
Amps Pin. Earth Design changes may occur
Config- Hour (over different current ratings)
uration Pos from one product to another.

63 3P+E 7 K9284 BLK K9844 BLK K9344 BLK

Suitable for flexible cable only. Suitable for flexible cable only. 63A With 32mm knockouts top
With external clamp With external clamp and bottom. Will accept FL13
flange top and bottom.
236 Commando

wiring devices | ingress protected www.mkelectric.co.uk

Plugs Connectors Socket Outlets


IP 44 ANGLED STRAIGHT ANGLED
SPLASHPROOF SURFACE PANEL MOUNTING PANEL MOUNTING
> 50V
100 - 300 Hz

Amps Pin. Earth


Config- Hour
uration Pos

16 3P+E 10 K9010 GRN K9110 GRN K9210 GRN K9410 GRN K9770 GRN

Fitted with cable entry gland. Fitted with cable entry gland. Top conduit (M20) or rear All flanges have the same fixing 16/32A new range has
cable entry, complete with centres and outside dimensions different fixing centres to
blanking plug. to assist panel builders. old range.
Minimised flange option Old range is available for
available (see page 240). limited period. See technical
IP 44 section for details.
SPLASHPROOF Plugs Connectors Socket Outlets
> 50V ANGLED STRAIGHT
300 - 500 Hz SURFACE PANEL MOUNTING

Amps Pin. Earth


Config- Hour
uration Pos

16 3P+E 2 K9011 GRN K9111 GRN K9211 GRN K9411 GRN


16 3P+N+E 2 K9017 GRN K9117 GRN K9252 GRN K9417 GRN
32 3P+N+E 2 K9047 GRN K9146 GRN K9258 GRN K9447 GRN

Fitted with cable entry gland. Fitted with cable entry gland. 16A Top conduit (M20) or All flanges have the same
rear cable entry, complete fixing centres and outside
with blanking plug. dimensions to assist panel
builders.
32A Top conduit (M25) or
rear cable entry, complete Minimised flange option
with blanking plug. available (see page 240).

Switch Socket
IP 44 Outlets
SPLASHPROOF ANGLED
> 50V INTERLOCKED
> 300 - 500 Hz SURFACE

Amps Pin. Earth


Config- Hour
uration Pos

16 3P+E 2 K9605 GRN

Switch can be locked in open or closed position.


Commando 237

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

Plugs Connectors Socket Outlets


IP 44 ANGLED STRAIGHT ANGLED
SPLASHPROOF SURFACE PANEL MOUNTING PANEL MOUNTING
IS TRAN ~
50 - 60 Hz

Amps Pin. Earth


Config- Hour
uration Pos

16 2P+E 12 K9004 GRY K9104 GRY K9204 GRY K9404 GRY K9756 GRY

Fitted with cable entry gland. Fitted with cable entry gland. Top conduit (M20) or rear All flanges have the same fixing 16/32A new range has
cable entry, complete with centres and outside dimensions different fixing centres to
blanking plug. to assist panel builders. old range.
Minimised flange option
available (see page 240). Old range is available for
limited period. See technical
section for details.
Plugs Connectors Socket Outlets
IP 44 ANGLED STRAIGHT
SPLASHPROOF SURFACE PANEL MOUNTING
>50 - 250V
d.c.

Amps Pin. Earth


Config- Hour
uration Pos

16 2P+E 3 K9003 GRY K9103 GRY K9203 GRY K9403 GRY

Fitted with cable entry gland. Fitted with cable entry gland. Top conduit (M20) or rear All flanges have the same
cable entry, complete with fixing centres and outside
blanking plug. dimensions to assist panel
builders.
Minimised flange option
available (see page 240).

All products are available in minimum order quantity of one.


Photographs feature the most representative products.
Design changes may occur (over different current ratings) from one
product to another.
238 Commando

wiring devices | ingress protected www.mkelectric.co.uk

Plugs Connectors Socket Outlets Appliance Inlets


IP 44 STRAIGHT ANGLED
SPLASHPROOF SURFACE PANEL MOUNTING SURFACE
25V
50 - 60 Hz

ELV RANGE
Amps Pin.
Config-
uration

16 2P K9018 VLT K9118 VLT K9253 VLT K9518 VLT K9725 VLT
16 3P K9019 VLT K9119 VLT K9254 VLT K9519 VLT K9726 VLT

Top conduit or rear cable entry. Top conduit or rear cable entry
Supplied with M25 blanking Supplied with M25 blanking
plug/cable entry. plug/cable entry.

Plugs Connectors Socket Outlets


IP 44 STRAIGHT ANGLED
SPLASHPROOF SURFACE PANEL MOUNTING
50V
50 - 60 Hz

ELV RANGE
Amps Pin. Minor
Config- Key
uration Pos

16 2P 12 K9020 W H I K9120 W H I K9255 W H I K9520 W H I


16 3P 12 K9021 W H I K9121 W H I K9256 W H I K9521 W H I

Top conduit or rear cable


entry. Supplied with M25 x 1.5
blanking plug/cable entry.

Plugs Connectors Socket Outlets


IP 44 STRAIGHT ANGLED
SPLASHPROOF SURFACE PANEL MOUNTING
25 & 50V
d.c.

ELV RANGE

Amps Pin. Minor


Config- Key
uration Pos

16 2P 10 K9022 W H I K9122 W H I K9257 W H I K9522 W H I

Top conduit or rear cable entry.


All violet and white products on this page are made of Polyamide Supplied with M25 blanking
plug/cable entry.
Commando 239

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

Three Way Comb i Blocks


Adaptor THREE WAY TWO WAY TWO WAY
110 - 130V 30 mA RCD
50 - 60 Hz PROTECTED
IP 44 SPLASHPROOF IP 44 SPLASHPROOF IP 57 WATERTIG HT IP 44 SPLASHPROOF

Amps Pin. Earth


Config- Hour
uration Pos

16 2P+E 4 K9907 YEL 13503 YEL 13507 YEL 13505 YEL

PBT e n c lo s u re Rubber housing Rubber housing Rubber housing


One appliance inlet and three
socket outlets
Three Way Comb i Blocks
Adaptor THREE WAY TWO WAY TWO WAY
200 - 250V 30 mA RCD
50 - 60 Hz PROTECTED
IP 44 SPLASHPROOF IP 44 SPLASHPROOF IP 57 WATERTIG HT IP 44 SPLASHPROOF

Amps Pin. Earth


Config- Hour
uration Pos

16 2P+E 6 K9908 BLU 13504 BLU 13508 BLU 13506 BLU

PBT e n c lo s u re Rubber housing Rubber housing Rubber housing


One appliance inlet and three
socket outlets

Three Way
Adaptor
380 - 415V
50 - 60 Hz
IP 44 SPLASHPROOF

Amps Pin. Earth


Config- Hour
uration Pos

16 3P+E 6 K9910 RED


16 3P+N+E 6 K9911 RED

PBT e n c lo s u re
One appliance inlet and three
socket outlets
240 Commando

wiring devices | ingress protected www.mkelectric.co.uk

Protective Covers M inimised and Spare FL Type Conduit Earth Lead


For Inlets Alternate Flanges Flange Plates Adaptors Adaptors And
Gland Plates And Blanking Plugs
Gaskets

9953

K9 9 9 2
9 9 33
9 9 60

9955
K9 9 9 7

K9 9 9 4
68 30

9 9 63
K9 9 9 5

K9 9 8 1/2/3

9960 BLK M in im is e d : 9952 K9991 9933


FOR 2P+ E, 16A GLAND PLATE FLEX IBLE CONDUIT ADAPTOR M20 X 1.5/ M20 X 1.5 THREAD SIZ E
K9996 USED ON ALL 16A SOCKET OUTLETS
UNDRILLED FL9 FOR USE WITH 2P+E/16A PLUGS &
9961 BLK FOR 2P+E, 16A AND APPLIANCE INLETS (EX CEPT
CONNECTORS M20 THREAD SIZ E
FOR 3P+ E, 16A
K9997 9953 INTERLOCKED). ALSO USED ON
FOR 3P+E, 3P+N+E, 16A
GLAND PLATE K9992 16A AND 25A SAFETY SWITCHES
9962 BLK UNDRILLED FL13 FLEX IBLE CONDUIT ADAPTOR
FOR 3P+ N+ E, 16A FOR USE WITH 3P+E/16A PLUGS &
9934
9954 M25 x 1.5/ M25 x 1.5 THREAD SIZ E
9963 BLK CONNECTORS M20 THREAD SIZ E USED ON ALL 32A SOCKET OUTLETS
A lt e r n a t e : GASKET FL9
FOR 3P+ N+ E, 32A K9993 AND APPLIANCE INLETS (EX CEPT
K9981 9955 INTERLOCKED)
9965 BLK FLEX IBLE CONDUIT ADAPTOR
FOR 2P+E, 16A GASKET FL13 FOR USE WITH 3P+N+E/16A PLUGS
FOR ALL 125 A (IP67 ) 9936
& CONNECTORS M20 THREAD SIZ E PG21/ M25 X 1.5 THREAD SIZ E
K9982 USED ON 16A & 32A INTERLOCKED
9966 BLK FOR 3P+E, 3P+N+E, 16A
2P+ E, 3P+ E, 32A K9994 SWITCHSOCKET OUTLETS
FLEX IBLE CONDUIT ADAPTOR
K9983 FOR USE WITH 2P+E & 3P+E/32A 9937
9967 BLK FOR 2P+E, 3P+E, 3P+N+E, 32A
FOR ALL 63A (IP44) PLUGS & CONNECTORS M32 X 1.5/ M32 X 1.5 THREAD SIZ E
M25 THREAD SIZ E USED ON ALL 63A SOCKET OUTLETS
AND APPLIANCE INLETS
K9995
FLEX IBLE CONDUIT ADAPTOR 6829
BLANKING PLUG/ CABLE ENTRY M16 X 1.5
FOR USE WITH 3P+N+E/32A PLUGS
& CONNECTORS M25 THREAD SIZ E 9988
BLANKING PLUG/ CABLE ENTRY M20 X 1.5
9989
BLANKING PLUG/ CABLE ENTRY M25 X 1.5
6830
BLANKING PLUG/ CABLE ENTRY M32 X 1.5

SUITABLE FOR SUITABLE FOR


IP44 PANEL SOCKET COM M AND O UNITS AND 9937 must not be used on installations
STRAIGHT OUTLETS SAFETYSWITCHES that are rated above 63 amps
Commando 241

technical hotline +44 (0)1268 563720 ingress protected | wiring devices

Commando Industrial Plugs and


Sockets

By referring to the chart Pilot C onta ct Ra ting C od e


below, it can be seen Commando accessories The rating code which is
that there can be no provided with pilot found on the rating label
interchangeability of contacts, in accordance of each accessory gives
products as the earth with IEC.60309: 1997 details of rated current,
socket tube is placed in a and BS EN.60309:1998 rated (operating) voltage
different clock position have pilot pins shorter (or range of voltages),
according to the voltage than other pins in the rated frequency (if not
and frequency. This clock unit. Connection to 50/60Hz) and a symbol
position is determined suitable control circuitry to indicate the position of
by looking into a socket- will provide electrical the earth contact.
outlet from the front interlock as the pilot circuit (i) For all products (except
with the key-way at the will make last and break extra low voltage) the
bottom. first relative to the mains position given is that of
Unless otherwise stated supply. the earth pin when a
all frequencies are The pilot contact is socket-outlet/connector
50-60Hz. positioned centrally in is viewed from the front
3P +E and 3P+N+E with the key-way at the
accessories and bottom. When viewing
diametrically opposite the a plug/ appliance inlet
earthing contact in from the front with the
2P+E accessories. key at the bottom, the
position of the earth pin is
reversed, ie., a 10 oclock
will appear at 2 oclock
and other positions are
relative.
(ii) For extra low voltage
products (ie., white and
violet) the position given
Voltage Colou r c ode is that of the minor key
when a socket-outlet is
25 viewed from the front
50 with the major key at the
bottom. When viewing a
3P + N + 100 - 130 plug/ appliance inlet from
3P
the front with the major
2P 200 - 250
250/440- key-way at the bottom,
265/460V
60H z 346 - 460 the position of the minor
key-way is reversed, ie.,
500 - 750 10 oclock will appear as
440-460V
60H z
> 50, 100 - 500Hz 2 oclock and other
> 50V
> 300-500H z
positions are relative.
> 50V > 50V
100-300H z > 300-500H z
MAJOR AND MINOR K EY POSITIONS FOR ELV SOC K ETS
> 50V
1112 1 > 300-500H z 25V

25V and 50V 50V

10 2 220/380V
120/208- 380V 50H z 50H z
144/250V ~
200-250V ~ 380-415V ~
9 3 > 50-250V
440V 60H z 250/440V
60H z

8 4
250V 7 6 5 100-130V ~

100-130V ~ No minor key Minor key at 10 oclock Minor key at 12 oclock


480-500V ~ 277V
60H z 57/100-
200-250V ~ 75/130V ~
Key for symbols
480-500V ~ 600-690V ~ a.c.
380-415V ~
d.c.
277/480- 347/600-
288/500V ~ 400/690V ~
isolating
200/346- transformer
240/415V ~

Das könnte Ihnen auch gefallen