HEAT EXCHANGER DESIGN

3.1 Can you have a cross-flow exchanger in which both flow are mixed? Discuss.

Answer:

Yes, as long as there is a mixing portion in the line of flow like the illustration below.

3.2 Find the appropriate mean radius, r , that will make Q = kA(r )T (ro ri ) , valid for the
one dimensional heat conduction through a thick spherical shell, where A(r ) = 4 r 2 (cf.
Example 3.1)

Solution:

1 2 (rT )
=0
r r 2
2 (rT )
=0
r 2
(rT )
= C1
r
rT = C1r + C 2
C
T = C1 + 2
r
At r = ro, T = To
At r = ri, T = Ti

Then,
C2
To = C1 +
ro
C
Ti = C1 + 2
ri
1
3. HEAT EXCHANGER DESIGN

Ti > To
1 1
Ti To = T = C 2
ri ro
(T T )(r r )
C2 = i o i o
(ro ri )
C (T T )r T r T r T r + T r
C1 = To 2 = To i o i = o o o i i i o i
ro (ro ri ) ro ri
T r T r
C1 = o o i i
ro ri
T r T r (T T )(r r )
T= oo ii+ i o io
ro ri (ro ri )r
dT (T T )(r r )
= i o i 2o
dr (ro ri )r
dT (T T )(r r )
Q = kA = k (4 r 2 ) i o i 2 o
dr (ro ri )r
k 4 ri ro (Ti To )
Q=
ro ri
k 4 ri ro T
Q=
ro ri
Equating:

kA(r )T k 4 ri ro T
Q= =
ro ri ro ri
2
k 4 r T k 4 ri ro T
=
ro ri ro ri
r = ri ro Answer.

3.3 Rework Problem 2.14, using the methods of Chapter 3.

Solution:
m& a = 0.5 kg/s
air At 20 C = 1.205 kg/m3
c pa At 20 C = 1006 J/kg.K
Cmin = m& a c pa = (0.5 kg/s)(1006 J/kg.K) = 503 W/K
U = 300 W/m2.K

Equation 3.22:

2
3. HEAT EXCHANGER DESIGN

lim = 1 e NTU
C max

UA
NTU =
Cmin
Q
Tcout = Tcin +
Cc
Cc = C min = 503 W/K
Tcin = 20 C
Q = Cmin (Thin Tcin )
Thin = 120 C

(a) q = U (Thin Tcin ) = (300 W/m2.K)(120 C 20 C) = 30,000 W/m2

(b) at x : A = (1 m)(x) = x m2
V = (1 m)(1 m)(x) = x m3

At the entrance:
dT
ma c pa = UA(Thin Tcin )
dt
dT
Vc pa = qA
dt
dT
xc pa = qx
dt
dT q 30000
= = = 24.75 C/s
dt c pa (1.205)(1006)

(c) x=2m

Q = Cmin (Thin Tcin )


UA (300)(2)
NTU = = =1.19284
C min 503
= 1 e 1.19284 = 0.69664
Q = (0.69664 )(503)(120 20) = 35,041 W
Q 35041
Tcout = Tcin + = 20 + = 89.7 C
Cc 503

3.4 2.4 kg/s of a fluid have a specific heat of 0.81 kJ/kg.K enters a counterflow heat
exchanger at 0 C and are heated to 400 C by 2 kg/s of a fluid having a specific heat of
0.96 kJ/kg.K entering the unit at 700 C. Show that to heat the cooled fluid to 500C, all
other conditions remaining unchanged, would require the surface area for a heat transfer
to be increased by 87.5 %.
3
3. HEAT EXCHANGER DESIGN

Solution:
Tcin = 0 C
Tcout = 400 C
Cc = (2.4 kg/s)(0.81 kJ/kg.K) = 1.944 kW/K
Thin = 700 C
Ch = (2 kg/s)(0.96 kJ/kg.K) = 1.92 kW/K
Q = Cc (Tcout Tcin ) = (1.944 kW/K)(400 0 K) = 777.6 kW
Q 777.6
Thout = Thin = 700 = 295 C
Ch 1.92
For counterflow heat exchanger

Ta = Thin Tcout = 700 C 400 C = 300 C


Tb = Thout Tcin = 295 C 0 C = 295 C
Ta Tb 300 295
LMTD = = = 297.5 C
Ta 300
ln ln

bT 295
Q
A=
U (LMTD )
Assume U is constant or unchanged at any new conditions.

Q 777.6
AU = = = 2.6138 kW/K
LMTD 297.5

if Tcout = 500 C

Q = Cc (Tcout Tcin ) = (1.944 kW/K)(500 0 K) = 972 kW


Q 992
Thout = Thin = 700 = 193.75 C
Ch 1.92
Ta = Thin Tcout = 700 C 500 C = 200 C
Tb = Thout Tcin = 193.75 C 0 C = 193.75 C
4
3. HEAT EXCHANGER DESIGN

Ta Tb 200 193.75
LMTD = = = 196.86 C
Ta 200
ln ln

bT 193.75
Q 972
AU = = = 4.9375 kW/K
LMTD 196.86

4.9375 2.6138
Percentage Increase = (100% ) = 88.9 %
2.6138

3.5 A cross-flow heat exchanger with both fluids unmixed is used to heat water (cp = 4.18
kJ/kg.K) from 40 C to 80 C, flowing at the rate of 1.0 kg/s. What is the overall heat
transfer coefficient if the hot engine oil (cp = 1.9 kJ/kg.K), flowing at the rate of 2.6 kg/s,
enters at 100 C? The heat transfer area is 20 m2. (Note that you can use either an
effectiveness or an LMTD method. It would be wise to use both as check.)

Solution:

Cross-flow heat exchanger: A = 20 m2.


Water: Cc = m& w cw = (1.0 kg/s)(4.18 kJ/kg.K) = 4.18 kW/K
Tcin = 40 C
Tcout = 80 C
Hot Engine Oil: Ch = m& o co = (2.6 kg/s)(1.9 kJ/kg.K) = 4.94 kW/K
Thin = 100 C
Heat Balance:
Q = Cc (Tcout Tcin ) = Ch (Thin Thout )
(4.18)(80 40) = (4.94)(100 T )
hout

Thout = 66.15 C

Use Effectiveness Method:

Eq. (3.16a)
C (T T ) (4.18)(80 40)
= c cout cin = = 0.667
Cmin (Thin Tcin ) (4.18)(100 40)

For cross-flow heat exchanger, both unmixed flow.


Fig. 3.17, = 0.667
Cmin Cc 4.18
= = = 0.85
Cmax Ch 4.94
UA
NTU = = 2.3
C min

5
3. HEAT EXCHANGER DESIGN

U (20 )
= 2 .3
4.18
U = 0.48 W/m2.K

Use LMTD Method:


T Tb
LMTD a
T
ln a
T b
Ta = 66.15 C 40 C = 26.15 C
Tb = 100 C 80 C = 20 C
26.15 20
LMTD = 22.94 C
26.15
ln
20
Q = UAF (LMTD )

Fig. 3.14 x, cross-flow heat exchanger, both passes unmixed.


Tt T tin
P = out
Tsin Ttin
Ts T sout
R = in
Ttout Ttin
use,

Tsin =100 C
T sout = 66.15 C
Ttout = 80 C
Ttin = 40 C
100 66.15
R= = 0.85
80 40
80 40
P= = 0.667
100 40
Then F = 0.81
Q = Cc (Tcout Tcin ) = UAF (LMTD )
(4.18 )(80 40 ) = U (20 )(0.81)(22.94 )
U = 0.45 W/m2.K

3.6 Saturated non-oil-bearing steam at 1 atm enters the shell pass of a two-tube-pass shell
condenser with thirty 20 ft tubes in each tube pass. They are made of schedule 160, in.
steel pipe (nominal diameter). A volume flow rate of 0.01 ft3/s of water entering at 60 F
enters each tube. The condensing heat transfer coefficient is 2000 Btu/h.ft2.F, and we

6
3. HEAT EXCHANGER DESIGN

calculate h = 1380 Btu/h.ft2.F for the water in the tubes. Estimate the exit temperature of
the water and the mass rate of condensate.

Solution:

Properties of water at 60 F (15.56 C).


w = 999 kg/m3 = 62.37 lbm/ft3.
c pw = 4.1887 kJ/kg.K = 1.000 Btu/lbm.F
For 30 tubes,
3 3
m& w = (0.01 ft /s)(62.37 lbm/ft )(30) = 18.711 lbm/s = 67,360 lbm/hr
Tcin = 60 F

Properties of steam at 1 atm (14.696 psia), from steam table of other references.
hfg = 1150.4 Btu/lbm 180.2 Btu/lbm = 970.2 Btu/lbm
Thin = Thout = 212 F

Properties of Sch. 160 Steel Pipe, in Nom. Diameter, from other references.

1 Btu / h. ft.F
k s = 43 W/m.K = 24.85 Btu/h.ft.F
1.7307 W / m.K
ri = (1/2)(0.612 in) = 0.306 in = 0.0255 ft
ro = (1/2)(1.050 in) = 0.525 in = 0.04375 ft

Based on outside area:


r
ro ln o
1 r
= o + ri + 1
U o ri hi ks ho
hi = 1380 Btu/h.ft.F, ho = 2000 Btu/h.ft.F
0.04375
0.04375 ln
1
=
0.04375
+ 0.0255
+
1
U o (0.0255)(1380) 24.85 2000
2
U o = 371 Btu/h.ft .F
U A
NTU = o o
C min
Ao = 2 ro L
L = 30 (20 ft)(2) = 1200 ft
Ao = 2 (0.04375)(1200 ) = 330 ft2.
Cmin = m& w c pw = (67,360 lbm/h)(1.000 Btu/lbm.F) = 67,360 Btu/h.F

7
3. HEAT EXCHANGER DESIGN

U o Ao (371)(330 )
NTU = = = 1.818
Cmin 67,360
= C lim = 1 e NTU = 1 e 1.818 = 0.838
max

Q = Cmin (Thin Tcin ) = (0.838)(67,360)(212 60) = 8,580,047 Btu/h

Exit Temperature of Water


Q = Cc (Tcout Tcin ) = m& wc pw (Tcout Tcin )
8,580,047 = (67,360)(Tcout 60 )
Tcout = 187.4 F

Mass flow rate of Condensate:


Q = m& c h fg
8,580,047 = m& c (970.2 )
m& c = 8,844 lbm/h

3.7 Consider a counterflow heat exchanger that must cool 3000 kg/h of mercury from 150 F
to 128 F. The coolant is 100 kg/h of water, supplied at 70 F. If U is 300 W/m2.K,
complete the design by determining reasonable value for the area and the exit-water
temperature.

Solution:
Mercury
Thin = 150 F = 65.56 C
Thout = 128 F = 53.33 C
m& m = 3000 kg/h = 0.833333 kg/s
c pm @ 60 C, Table A.3, pg.707 = 138.244 J/kg.K

Water
Tcin = 70 F = 21.11 C
m& w = 100 kg/h = 0.027778 kg/s
c pw @ 21.11 = 4187.3 J/kg.K

U = 300 W/m2.K

Cc = mwc pw = (0.027778)(4183.7) = 116.2 W/K


Ch = mm c pm = (0.833333)(138.244) = 115.2 W/K

Effectiveness Method

8
3. HEAT EXCHANGER DESIGN

For counterflow heat exchanger:


C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max
C min = 115.2 W/K
C max = 116.2 W/K

Solve for .
Q = Cmin (Thin Tcin ) = Ch (Thin Thout )
Ch (Thin Thout )
=
Cmin (Thin Tcin )

=
(115.2)(65.56 53.33) = 0.275
(115.2)(65.56 21.11)
Then:
115.2
1 exp 1 NTU
= 0.275 = 116.2
115.2 115.2
1 exp 1 NTU
116.2 116.2
0.275(1 0.9914e 0.008606 NTU
) = 1 e 0.008606 NTU
e 0.008606 NTU = 0.996749
NTU = 0.37843

UA (300) A
NTU = = = 0.37843
C min 115.2
A = 0.1453 m2.

Q C h (Thin Thout )
Tcout = Tcin + = Tcin +
Cc Cc
115.2(65.56 53.33)
Tcout = 21.11 + = 33.24 C = 91.83 F
116.2

3.8 An automobile air-conditioner gives up 18 kW at 65 km/h if the outside temperature is 35


C. The refrigerant temperature is constant at 65 C under these conditions, and the air rises
6 C in temperature as it flows across the heat exchanger tubes. The heat exchanger is of
the finned-tube type shown in Fig. 3.6b, with U 200 W/m2.K. If U ~ (air velocity)0.7
and the mass flow rate increases directly with the velocity, plot the percentage reduction
of heat transfer in the condenser as a function of air velocity between 15 and 65 km/h.

9
3. HEAT EXCHANGER DESIGN

Solution:
Let C1 and C2 are constant, V = air velocity, km/h.
m& a = C1V
U = C 2V 0.7
Solving for C2.
U = 200 = C 2 (65)
0.7

C2 = 10.76442

Solving for LMTD.


T Tb
LMTD = a
T
ln a
T b
Ta = Tr Tcin = 65 C 35 C = 30 C
Tb = Tr Tcout
Tcout Tcin = 6 C
Tcout = 35 C + 6 C = 41 C
Tb = Tr Tcout = 65 C 41 C = 24 C
Ta Tb 30 24
LMTD = = = 26.89 C
Ta 30
ln ln
T b
24
Solving for A.
Q = UA(LMTD )
18000 = (200 )A(26.89 )
A = 3.347 m2.

Solving for m& a


c pa = 1007 J/kg.K
Q = m& a c pa (Tcout Tcin )
Q = m& a (1007 )(6 )
m& a = 2.979 kg/s
Solving foe C1.
m& a = C1V
2.979 = C1 (65)
C1 = 0.04583

Then at any air velocity:


m& a = 0.04583V
10
3. HEAT EXCHANGER DESIGN

U = 10.76442V 0.7

Solving for NTU.


UA
NTU =
Cmin
Cmin = m& a c pa = (0.04583V )(1007 ) = 46.15V

NTU =
(10.76442V )(3.347 ) = 0.7807
0.7

46.15V V 0.3

Solving for :
lim = 1 e NTU
= C max
0.7807
= 1 exp
V
0.3

Q = Cmin (Thin Tcin )



0.7807
Q = 1 exp (46.15V )(65 35)
V
0.3

0.7807
Q = 1384.5V 1 exp
V
0.3

Percentage reduction , x, %.

x=
Q Q
(100% ) = 1 1384.5V 1 exp 0.7807 (100 )

0.3
Q 18000 V
0.7807
x = 1001 0.07692V 1 exp
V
0.3

Tabulation:

V , km/h x, %
15 66.2
20 58.1
25 50.6
30 43.4
35 36.6
40 30.0
45 23.7
50 17.5
55 11.5
60 5.7
65 0.0

11
3. HEAT EXCHANGER DESIGN

Plot:

3.9 Derive eqn. (3.21).

Solution:
Eq. (3.21), Counter-flow:

C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
Cmax Cmax

Derivation:

Equation (3.17)
Q = Cmin (Thin Tcin ) = Cc (Tcout Tcin )
Equation (3.18)
UA
NTU =
Cmin
Equation (3.9)
Ta 1 1
ln = UA
C Cc C h
1 + c (Tcin Tcout ) + Ta
Ch

C
1 + c (Tcin Tcout ) + Ta
Ch 1 1
ln = UA
Ta Cc C h
Ta = Thin Tcout from Eq. 3.8 , counterflow.
12
3. HEAT EXCHANGER DESIGN

Then
Ta = Thin Tcin (Tcout Tcin )
Q Q
Ta =
Cmin Cc
Let Cc = Cmin , Ch = Cmax
Q(1 )
Ta =
Cmin
Cmin Q
1 +
Cmax C min UA Cmin
ln +1 = 1
Q (1 ) Cmin Cmax
Cmin

C Cmin
ln 1 min + 1 = 1 NTU
Cmax 1 Cmax
Cmin
1 + 1
ln
Cmax = 1 Cmin NTU
1 Cmax


C min
+1
ln
C max = 1 Cmin NTU
1 Cmax




ln
1 = 1 Cmin NTU
C min C
max
C +1
max
1 C
= exp 1 min NTU
C Cmax
min + 1
C max
Cmin C C
1 = exp 1 min NTU + exp 1 min NTU
Cmax C max Cmax
C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max

13
3. HEAT EXCHANGER DESIGN

3.10 Derive the infinite NTU limit of the effectiveness of parallel and counterflow heat
exchangers at several values of Cmin/Cmax. Use common sense and the First Law of
Thermodynamics, and refer to eqn. (3.20) and eqn. (3.21) only to check your results.

Solution:
Eq. (3.20) Parallel
C
1 exp 1 + min NTU
= Cmax
Cmin
1+
Cmax
Eq. (3.21) Counterflow

C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max
By energy balance, First Law of Thermodynamics.
Q
Thout = Thin
Ch
Q
Tcout = Tcin +
Cc

For Parallel Flow:


Thout = Tcout
Then
Q
Tcout = Thin
Ch
Q
Tcout = Tcin +
Cc
1 1 Q C min
Thin Tcin = Q + = 1 +
Cc C h Cmin C max
C
Thin Tcin = (Thin Tcin )1 + min
C max
1
=
C
1 + min
Cmax

14
3. HEAT EXCHANGER DESIGN

C
Check with Eq. (3.20) with 1 exp 1 + min NTU = 0
Cmax
C
1 exp 1 + min NTU
= Cmax = 1+ 0
C C
1 + min 1 + min
Cmax Cmax
1
=
C
1 + min
Cmax

For Counterflow
Thin = Tcout
Q = Cmin (Thin Tcin ) = Cc (Tcout Tcin )
Q = Cmin (Thin Tcin ) = C min (Thin Tcin )
=1

C
Check with Eq. (3.21) with 1 exp 1 + min NTU = 0
Cmax
C
1 exp 1 min NTU
= C max = 1+ 0
C C 1+ 0
1 min exp 1 min NTU
C max Cmax
=1

3.11 Derive the equation = ( NTU , C min Cmax ) for the heat exchanger depicted in Fig. 3.9.

Solution:
= ( NTU , Cmin Cmax )

Eq. (3.22), Cmax


lim = 1 e NTU
= C max
Derivation for Parallel Flow
C
1 exp 1 + min NTU
= Cmax
Cmin
1+
Cmax

15
3. HEAT EXCHANGER DESIGN

1 exp[ (1 + 0)NTU ]
=
1+ 0
= lim = 1 e NTU
C max

Derivation for Counterflow


C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max
1 exp[ (1 0 )NTU ]
=
1 (0) exp[ (1 0 )NTU ]
lim = 1 e NTU
= C max

3.12 A single-pass heat exchanger condenses steam at 1 atm on the shell side and heats water
from 10 C to 30 C on the tube side with U = 2500 W/m2.K The tubing is thin-walled, 5
cm in diameter, and 2 m in length. (a) Your boss asks whether the exchanger should be
counterflow or parallel flow. How do you advise her? Evaluate: (b) the LMTD; (c) the
m& H 2O ; (d) .

Solution:

(a) I will advise here that counterflow or parallel flow configuration is irrelevant. The
temperature on the hot side is constant.
(b) For steam, Th = 100 C
For water, Tcin = 10 C
Tcout = 30 C
c p = 4187 J/kg.K
For tubing, D = 5 cm = 0.05m
L=2m
A = DL
Ta Tb
LMTD =
T
ln a
T b
Ta =100 C 10 C = 90 C
Tb = 100 C 30 C = 70 C
90 70
LMTD = = 79.58 C
90
ln
70

16
3. HEAT EXCHANGER DESIGN

(c) Q = UA( LMTD ) = m& H 2O c p (Tcout Tcin )

(2500)( )(0.05) (2)(79.58) = m& (4187)(30 10)


2
H 2O

m& H 2O = 0.7464 kg/s

lim = 1 e NTU
(d) = C max

NTU =
UA
=
UA
=
(2500 )( )(0.05) (2) = 0.2153
2

C min m& H 2 O c p (0.7464)(4187 )


= 1 e 0.2513 = 0.2222

3.13 Air at 2 kg/s and 27 C and a stream of water at a1.5 kg/s and 60 C each enter a heat
exchanger. Evaluate the exit temperatures if A = 12 m2, U = 185 W/m2.K, and:
a. The exchanger is parallel flow;
b. The exchanger is counterflow;
c. The exchanger is cross-flow, one stream mixed;
d. The exchanger is cross-flow. Neither stream mixed.

Solution:
m& a = 2 kg/s
m& w = 1.5 kg/s
Tcin = 27 C
Thin = 60 C
A = 12 m2
U = 185 W/m2.K

Specific heat of air at 27 C = cpa = 1007 J/kg.K


Specific heat of water at 60 C = cpw = 4186.2 J/kg.K

Cc = m& a cpa = (2 kg/s)(1007 J/kg.K) = 2014 W/K = Cmin


Ch = m& w cpw = (1.5 kg/s)(4186.2 J/kg.K) = 6279.3 W/K = Cmax

(a) Eq. 3.20 for parallel flow


C
1 exp 1 + min NTU
= Cmax
Cmin
1+
Cmax
UA (185)(12 )
NTU = = = 1.1023
C min (2014)
17
3. HEAT EXCHANGER DESIGN

2014
1 exp 1 + (1.1023)
= 6279.3 = 0.5806
2014
1+
6279.3
Q = Cmin (Thin Tcin )
Q = (0.5806 )(2014 )(60 27 ) = 38,587.8 W

Q 38,587.8
Thout = Thin = 60 = 53.86 C
Ch 6279.3
Q 38,587.8
Tcout = Tcin + = 27 + = 46.16 C
Cc 2014

(b) Eq. 3.21 for counterflow

C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max
2014
1 exp 1 (1.1023)
= 6279.3 = 0.6213
2014 2014
1 exp 1 (1.1023)
6279.3 6279.3
(
Q = Cmin Thin Tcin )
Q = (0.6213)(2014)(60 27 ) = 41,292.8 W

Q 41,292.8
Thout = Thin = 60 = 53.42 C
Ch 6279.3
Q 41,292.8
Tcout = Tcin + = 27 + = 47.50 C
Cc 2014

(c) For cross-flow, one stream mixed, Figure 3.17b


NTU = 1.103
C mixed C 2014
= min = = 0.32
Cunmixed C max 6279.3
Then, = 0.60
Q = Cmin (Thin Tcin )
Q = (0.60 )(2014 )(60 27 ) = 39,877.2 W

18
3. HEAT EXCHANGER DESIGN

Q 39,877.2
Thout = Thin = 60 = 53.65 C
Ch 6279.3
Q 39,877.2
Tcout = Tcin + = 27 + = 46.80 C
Cc 2014

(d) For cross-flow, neither stream mixed, Figure 3.17a


NTU = 1.103
C mixed C 2014
= min = = 0.32
Cunmixed C max 6279.3
Then, = 0.60
Q = Cmin (Thin Tcin )
Q = (0.60 )(2014 )(60 27 ) = 39,877.2 W

Q 39,877.2
Thout = Thin = 60 = 53.65 C
Ch 6279.3
Q 39,877.2
Tcout = Tcin + = 27 + = 46.80 C
Cc 2014

3.14 Air at 0.25 kg/s and 0 C enters a cross-flow heat exchanger. It is to be warmed to 20 C by
0.14 kg/s of air at 50 C. The streams are unmixed. As a first step in the design process,
plot U against A and identify the approximate range of area for the heat exchanger.

Solution:

m& a1 = 0.25 kg/s


Tcin = 0 C
Tcout = 20 C
m& a 2 = 0.14 kg/s
Thin = 50 C

Specific heat of air at 10 C (average of 0 C and 20 C) = c pa1 = 1006 J/kg.K


Specific heat of air at 50 C = c pa 2 = 1008 J/kg.K

Cc = m& a1c pa1 = (0.25 kg/s)(1006 J/kg.K) = 251.5 W/K = Cmax


Ch = m& a 2 c pa 2 = (0.14 kg/s)(1008 J/kg.K) = 141.12 W/K = Cmin

Q = Cmin (Thin Tcin ) = Cc (Tcout Tcin ) = Ch (Thin Thout )


Cc (Tcout Tcin ) = Ch (Thin Thout )

19
3. HEAT EXCHANGER DESIGN

(251.5)(20 0 ) = (141.12)(50 T ) hout

Thout = 14.36 C
Cmin (Thin Tcin ) = Cc (Tcout Tcin )
(141.12 )(50 0) = 251.5(20 0)
= 0.713

Fig. 3.17a, cross-flow unmixed,

C min 141.12
= = 0.56
Cmax 251.5
= 0.713

Then,

UA
NTU = =2
Cmin
UA = 2(141.12) = 282.24 W/K

Table 2.2, Typical range of magnitudes of U for Air-to-Air is U = 60 550 W/m2.K

Plot:

282.24
At 60 W/m2.K, A = = 4.704 m2
60
282 .24
At 550 W/m2.K, A = = 0.513 m2
550
Range of area = 0.513 m2 to 4.704 m2.

20
3. HEAT EXCHANGER DESIGN

3.15 A particular two shell-pass, four tube-pass heat exchanger uses 20 kg/s of river water at
10 C on the shell side to cool 8 kg/s of processed water from 80 C to 25 C on the tube
side. At what temperature will the coolant be returned to the river? If U is 800 W/m2.K,
how large must the exchanger be?

Solution:
Shell side:
m& r = river water = 20 kg/s
Tsin = Tcin = 10 C
Tube side:
m& p = processed water = 8 kg/s
Ttin = Thin = 80 C
Ttout = Thout = 25 C
Specific heat of water at 52.5 C (average of 80 C and 25 C), c pp = 4183.2 J/kg.K
Specific heat of water at 10 C , c pr = 4196.2 J/kg.K
Cc = m& r c pr = (20 kg/s)(4196.2 J/kg.K) = 83,924 W/K
Ch = m& p c pp = (8 kg/s)(4183.2 J/kg.K) = 33,465.6 W/K
Using LMTD Method:
LMTD = in
(Th Tcout ) (Thout Tcin )
T T
ln hin cout
Th Tc
out in
Solving for Tcout ;
Q = Ch (Thin Thout ) = Cc (Tcout Tcin )
(33,465.6 )(80 25) = (83,924 )(T cout 10 )
Tcout = 31.93 C = Tsout

LMTD =
(Thin Tcout ) (Thout Tcin )
T T
ln hin cout
Th Tc
out in

LMTD =
(80 31.93) (25 10) = 28.4 C
80 31.93
ln
25 10
U = 800 W/m2.K
Tt Ttin 25 80
P = out = = 0.786
Tsin Ttin 10 80
Tsin Tsout 10 31.93
R= = = 0.40
Ttout Ttin 25 80
21
3. HEAT EXCHANGER DESIGN

For two shell-pass, four tube-pass heat exchanger, Fig. 3.14b


With P = 0.786, R = 0.4, then F = 0.936

Q = UAF (LMTD ) = C h (Thin Thout )


(800)A(0.936)(28.4) = (33,465.6)(80 25)
A = 86.552 m2.

3.16 A particular cross-flow process heat exchanger operates with the fluid mixed on one side
only. When it is new, U = 2000 W/m2.K, Tcin = 25 C, Tcout = 80 C, Thin = 160 C and Thout =
70 C. After 6 months of operation, the plant manager reports that the hot fluid is only
being cooled to 90 C and that he is suffering a 30% reduction in total heat transfer. What
is the fouling resistance after 6 months of use? (Assume no reduction of cold-side flow
rate by fouling.)

Solution:

U = 2000 W/m2.K
Tcin = 25 C
Tcout = 80 C
Thin = 160 C
Thout = 70 C
Use LMTD Method:
LMTD1 = in
(Th Tcout ) (Thout Tcin ) = (160 80) (70 25) = 60.83 C
T T 160 80
ln hin cout ln
Th Tc 70 25
out in

Q = UAF (LMTD )
Q1 = U 1 AF1 (LMTD1 )
Tt Ttin 70 160
P = out = = 0.67
Tsin Ttin 25 160
Tsin Tsout25 80
R= = = 0.611
Ttout Ttin 70 160
Fig. 3.17d, cross-flow, fluid mixed on one side only, F1 = 0.76
Q1 = U 1 A(0.76 )(60.83) = 46.23U 1 A
with Q2 = (1 0.30 )Q1 = 0.70Q1
Thout = 90 C

22
3. HEAT EXCHANGER DESIGN

LMTD2 =
(Thin Tcout ) (Thout Tcin )
=
(160 80) (90 25) = 72.24 C
T T 160 80
ln hin cout ln
Th Tc 90 25
out in

Q2 = U 2 A(0.90 )(72.24 ) = 65.02U 2 A


Q2 = 0.70Q1
65.02U 2 A = 0.70(46.23)U 1 A
U 2 = 0.4977U 1
1 1 1 1 1.00924
Rf = = 1 =
U 2 U 1 0.4977 U 1 U1
1.00924
Rf = = 0.0005 m2.K/W
2000

3.17 Water at 15 C is supplied to a one shell-pass, two tube-passes heat exchanger to cool 10
kg/s of liquid ammonia from 120 C to 40 C. You anticipate a U on the order of 1500
W/m2.K when the water flows in the tubes. If A is to be 90 m2, choose the correct flow
rate of water.

Solution:

m& a = 10 kg/s
Tsin = Thin = 120 C
Tsout = Thout = 40 C
Ttin = Tcin = 15 C
U = 1500 W/m2.K
A = 90 m2.

Specific heat of water at 15 C, c pw = 4189.4 J/kg.K


Specific heat of liquid ammonia at 80 C (average of 120 C and 40 C).
c pa = 5838.1 J/kg.K

Cc = m& a c pa = (10)(5838.1) = 58,381 W/K


Try C min = Cc = 58,381 W/K
Use Fig. 3.17c (one shell-pass, two tube-passes)
UA (1500 )(90)
NTU = = = 2.312
C min 58,381
Q = Cmin (Thin Tcin ) = Ch (Thin Thout )
Cmax = Ch

23
3. HEAT EXCHANGER DESIGN

Cmin (120 15) = Cmax (120 40)


Cmin
= 0.762
C
max
From Fig. 3.17c, NTU = 2.312
Tabulation:
Cmin Cmin

Cmax Cmax
0.25 0.80 0.20
0.50 0.72 0.36
0.75 0.64 0.48
1.00 0.58 0.58
C
Since min < 0.762, Cmin Cc
Cmax
Use Cmin = Ch
Q = Cmin (Thin Tcin ) = Cmin (Thin Thout )
(120 15) = (120 40)
= 0.762
Cmax = Cc = 58,381 W/K
UA (1500)(90 ) 135,000
NTU = = =
C min Cmin Cmin
Fig. 3.17
Tabulation: = 0.762
Cmin NTU C C min from NTU
C min from min
Cmax Cmax
0.25 1.9 14595 71053
0.375 2.5 21893 54000
0.5 3.6 29191 38571

By extrapolation:
x 21893 x 54000
=
29191 21893 38571 54000
x 54000 = 2.11414( x 21893)
x = 32,203 = C min

or
C min
= 0.375 +
(32203 21893) (0.5 0.375) = 0.552
C max (29191 21893)
Cmin = 0.552(58,381) = 32,226 W/K

24
3. HEAT EXCHANGER DESIGN

Or
NTU = 2.5 +
(32203 21893) (3.6 2.5) = 4.05
29191 21893
135,000
NTU =
Cmin
135,000 135,000
Cmin = = = 33,333
NTU 4.05

Then:
1
Cmin = (32203 + 32226 + 33333) = 32,587 W/K
3
and
Cmin = m& w c pw
32,587 = m& w (4189.4 )
m& w = 7.8 kg/s

3.18 Suppose that the heat exchanger in Example 3.5 had been a two shell-pass, four tube-pass
exchanger with the hot fluid moving in the tubes. (a) What would be the exit temperature
in this case? (b) What would be the area if we wanted the hot fluid to leave at the same
temperature that it does in the example?

Solution:
From Example 3.5
Tcin = 40 C
Cc = 20,000 W/K
Thin = 150 C
C h = 10,000 W/K
A = 30 m2
U = 500 W/m2.K

Answer from Ex. 3.5, Thout = 84.44 C

(a) Fig. 3.17d, two shell-pass, four tube-pass heat exchanger


Cmin = Ch = 10,000 W/K
Cmax = Cc = 20,000 W/K
UA (500)(30 )
NTU = = = 1.5
C min 10,000
C min 10,000
= = 0.5
C max 20,000
= 0.673
25
3. HEAT EXCHANGER DESIGN

Q = Cmin (Thin Tcin ) = (0.673)(10,000)(150 40) = 740,300 W


Q 740,300
Thout = Thin = 150 = 75.97 C
Ch 10,000

(b) Thout = 84.44 C

Q = Cmin (Thin Tcin ) = Cmin (Thin Thout )


Thin Thout 150 84.44
= = = 0.596
Thin Tcin 150 40
Cmin
= 0.5
Cmax
Fig. 3.17d, two shell-pass, four tube-pass heat exchanger,

UA
NTU = = 1.14
C min
(500)( A) = (1.14)(10,000)
A = 22.8 m2.

3.19 Plot the maximum tolerable fouling resistance as a function of Unew for a counterflow
exchanger, with given inlet temperature, if a 30 % reduction in U is the maximum that
can be tolerated.

Solution:

1 1
= Rf +
U old U new
if U old = (1 0.30)U new = 0.70U new
Then:
1 1 1
= = Rf +
U old 0.70U new U new
1 1
1 = Rf
0.70 U new
3
Rf =
7U new

26
3. HEAT EXCHANGER DESIGN

3.20 Water at 0.8 kg/s enters the tubes of a two-shell-pass, four-tube-pass heat exchanger at 17
C and leaves at 37 C. It cools 0.5 kg/s of air entering the shell at 250 C with U = 432
W/m2.K. Determine: (a) the exit air temperature; (b) the area of heat exchanger; and (c)
the exit temperature if, after some time, the tubes become fouled with Rf = 0.0005
m2K/W.

Solution:

m& w = 0.8 kg/s


Tcin = 17 C
Tcout = 37 C
m& a = 0.5 kg/s
Thin = 250 C
U = 432 W/m2.K
c pw at 27 C = 4181 J/kg.K
c pa at 250 C = 1035 J/kg.K
Cc = mwc pw = (0.8)(4181) = 3344.8 W/K
Ch = ma c pa = (0.5)(1035) = 517.5 W/K

(a) Solve for exit air temperature.


Cc (Tcout Tcin ) = Ch (Thin Thout )
(3344.8)(37 17 ) = (517.5)(250 T ) hout

Thout = 120.74 C

(b) Solving for the area of the heat exchanger.


Q = UAF (LMTD )

27
3. HEAT EXCHANGER DESIGN

LMTD =
(T hin Tcout ) (Thout Tcin )
=
(250 37) (120.74 17) = 151.88 C
T T 250 37
ln hin cout ln
Th Tc 120.74 17
out in

For two-shell-pass, four-tube-pass heat exchanger, use Fig. 3.14b


Ttout = 37 C
Ttin = 17 C
Tsin = 250 C
Tsout = 120.74 C
Ttout Ttin 37 17
P= = = 0.086
Tsin Ttin 250 17
Tsin Tsout 250 120.74
R= = = 6.463 > 1
Ttout Ttin 37 17
Since R > 1, use reciprocal rule.
P = PR = (0.086)(6.463) = 0.56
R = 1/R = 1/(6.463) = 0.155
Fig. 3.14b, F ~ 1.0
Then,
Q = Cc (Tcout Tcin ) = (3344.8)(37 17 ) = 66,896 W
U = 432 W/m2.K
Q = UAF (LMTD )
66,496 = (432)(A)(1.0)(151.88)
A = 1.02 m2.

(c) Exit temperature if Rf = 0.0005 m2K/W


1 1
= Rf +
U U
1 1
= 0.0005 +
U 432
U = 355.3 W/m2.K
Cmin = Ch = 517.5 W/K
Cmax = Cc = 3344.8 W/K
U A (355.3)(1.02 )
NTU = = = 0.7003
C min 517.5

Fig. 3.17b, two-shell-pass, four-tube-pass heat exchanger.


C min 517.5
= = 0.155
C max 3344.8
NTU = 0.7003
Then, = 0.47
28
3. HEAT EXCHANGER DESIGN

Q = Cmin (Thin Tcin ) = (0.47 )(517.5)(250 17 ) = 56,671 W


Q 56,671
Tcout = Tc in + = 17 + = 34 C
Cc 3,344.8
Q 56,671
Thout = Thin = 250 = 140.5 C
Ch 517.5

3.21 You must cool 78 kg/min of a 60%-by-pass mixture of glycerin in water from 108 C to
50 C using cooling water available at 7 C. Design a one-shell-pass, two-tube-pass heat
exchanger if U = 637 W/m2.K. Explain any design decision you make and report the area,
TH 2Oout , and any other relevant features.

Solution:
m& g = 78 kg/min
Thin = 108 C
Thout = 50 C
Tcin = 7 C
c pg at 79 C of 60 % glycerin in water = 3474 J/kg.K
c pw at 7 C = 4201 J/kg.K
One-shell-pass, two-tube-pass heat exchanger. Fig. 3.17c
Ch = m& g c pg = (78)(3474)/60 = 4516.2 W/K
Q = Ch (Thin Thout ) = (4516.2)(108 50) = 261,940 W
Q = Cmin (Thin Tcin )
say C min = Ch = 4516.2 W/K
Q = (4516.2)(108 7 ) = 261,940
= 0.5743

assume C min = Cmax


Cmin
= 1.0
C max
then, NTU = 2.32

UA
NTU =
Cmin

2.32 =
(637 )A
4516.2
A = 16.45 m2.
Check for F-factor, LMTD = 50 C 7 C = 43 C

29
3. HEAT EXCHANGER DESIGN

Q = UAF (LMTD )
261,940 = (637)(16.45)(F)(43)
F = 0.58, very small

Cmin
Say = 0.5, = 0.5743
C max
then, NTU = 1.091

UA
NTU =
Cmin

1.091 =
(637 )A
4516.2
A = 7.735 m2.
Check for F-factor
Cmax = 2C min = 2(4516.2) = 9032.4 W/K
Q 261,940
Tcout = Tc in + = 7+ = 36 C
Cc 9,032.4

LMTD = in
(Th Tcout ) (Thout Tcin ) = (108 36) (50 7) = 56.26 C
T T 108 36
ln hin cout ln
Th Tc 50 7
out in

Q = UAF (LMTD )
261,940 = (637)(7.735)(F)(56.26)
F = 0.95
From. Fig. 3.14a
Tt Ttin
P = out
Tsin Ttin
Tsin Tsout
R=
Ttout Ttin
Ttout = 50 C
Ttin = 108 C
Tsin = 7 C
Tsout = 36 C
50 108
P= = 0.574
7 108
7 36
R= = 0.5
50 108
Then F = 0.90 < 0.95

30
3. HEAT EXCHANGER DESIGN

Cmin
Say = 0.25
C max
= 0.5743
then, NTU = 0.9545

UA
NTU =
Cmin

0.9545 =
(637 )A
4516.2
A = 6.7672

Cmax = 4C min = 4(4516.2) = 18,064.8 W/K

Q 261,940
Tcout = Tc in + = 7+ = 21.5 C
Cc 18,064.8

LMTD = in
(Th Tcout ) (Thout Tcin ) = (108 21.5) (50 7) = 62.24 C
T T 108 21.5
ln hin cout ln
Th Tc 50 7
out in

Q = UAF (LMTD )
261,940 = (637)(6.7672)(F)(62.24)
F = 0.976
From. Fig. 3.14a
Tt Ttin
P = out
Tsin Ttin
Tsin Tsout
R=
Ttout Ttin
Ttout = 50 C
Ttin = 108 C
Tsin = 7 C
Tsout = 21.5 C
50 108
P= = 0.574
7 108
7 21.5
R= = 0.25
50 108
Then F = 0.96 < 0.976

By extrapolation:
x 0.95 x 0.90
=
0.976 0.95 0.96 0.90
31
3. HEAT EXCHANGER DESIGN

2.3077( x 0.95) = x 0.90


x = 0.99

From Fig. 3.14a, for F = x = 0.99 at P = 0.574


R ~ 0.099
C
But R = min = 0.099
Cmax
C min = 4516.2 W/K
C max = 4516.2 / 0.099 = 45,618 W/K
Q = 261,940 W
C
Fig. 3.17c, = 0.5743, min = 0.099
C max
UA
NTU = = 0.895
C min

0.895 =
(637 )A
4516.2
A = 6.35 m2.
Check for F.
Q 261,940
Tcout = Tc in + = 7+ = 12.74 C
Cc 45,618

LMTD = in
(Th Tcout ) (Thout Tcin ) = (108 12.74) (50 7) = 65.70 C
T T 108 12.74
ln hin cout ln
Th Tc 50 7
out in

Q = UAF (LMTD )
261,940 = (637)(6.35)(F)(65.70)
F = 0.99 = 0.99 o.k.

Therefore:
A = 6.35 m2.
TH 2Oout = 12.74 C
Cmin
= 0.099
Cmax
= 0.5743

3.22 A mixture of 40%-by-weight glycerin, 60%-water, enters a smooth 0.113 m I.D. tube at
30 C. The tube is kept at 50 C, and m& mixture = 8 kg/s. The heat transfer coefficient inside the
pipe is 1600 W/m2.K. Plot the liquid temperature as a function of position in the pipe.

Solution:
Tcin = 30 C
32
3. HEAT EXCHANGER DESIGN

m& g = 8 kg/s
hi = 1600 W/m2.K
Thin = Thout = 50 C

c pg at 30 C, 40%-glycerin = 3480 J/kg.K


Cmin = Cc = m& g c pg = (8)(3480) = 27,840 W/K
Cmax
Cmin
=0
C max
C
lim = 1 e NTU
max

Q = Cmin (Thin Tcin ) = Cc (Tcout Tcin )


Cmin (Thin Tcin ) = C min (Tcout Tcin )
Tcout = (Thin Tcin ) + Tcin
UA hi A
NTU = =
C min C min
A = Dx
where x position in pipe from Tcin .
Tcout = (1 e NTU ) (Thin Tcin ) + Tcin
hi A hi (Dx )
NTU = =
C min Cmin

NTU =
(1600 )( )(0.113)x = 0.0204 x
27840
Tcout = (1 e 0.0204 x
)(50 30) + 30
Tcout = 50 20e 0.0204 x

Tabulation:
x, m Tcout = 50 20e 0.0204 x , C
0 30
1 30.4
2 30.8
3 31.2
4 31.6
5 31.9
6 32.3
7 32.7
8 33.0
9 33.4

33
3. HEAT EXCHANGER DESIGN

10 33.7
20 36.7
30 39.2
40 41.2
50 42.8
50.0

Plot:

3.23 Explain in physical terms why all effectiveness curves Fig. 3.16 and Fig. 3.17 have the
same slope as NTU 0. Obtain this slope from eqns. (3.20) and (3.21).

Solution:
For parallel flow, Eq. (3.20)
C
1 exp 1 + min NTU
= Cmax
C
1 + min
Cmax
For counterflow, Eq. (3.21)

C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max

Slope for parallel flow:

34
3. HEAT EXCHANGER DESIGN

C
1 exp 1 + min NTU
= Cmax
Cmin
1+
Cmax
Cmin C
1 + exp 1 + min NTU
d Cmax Cmax
=
dNTU Cmin
1+
Cmax
d C
= exp 1 + min NTU
dNTU Cmax
if NTU = 0

d C
= 1 , independent of min , therefore, the same for all.
dNTU Cmax

Slope for counterflow:


C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max
Cmin C C C C C C C Substitut
1 exp 1 min NTU 1 min exp 1 min NTU 1 exp 1 min NTU min 1 min exp 1 min NTU
d C C max Cmax Cmax Cmax Cmax Cmax Cmax
=
max
2
dNTU Cmin C
1 exp 1 min NTU
Cmax Cmax
e, NTU = 0.
Cmin C min C C
1 1 (1 1) min 1 min
d C max C max Cmax C max
= 2
dNTU Cmin
1
Cmax
Cmin C min C C
1 1 (1 1) min 1 min
d C max C max Cmax C max
= 2
dNTU Cmin
1
Cmax
d C
= 1 , also independent of min , therefore, the same for all.
dNTU Cmax

35
3. HEAT EXCHANGER DESIGN

3.24 You want to cool air from 150 C to 60 C but you cannot afford a custom-built heat
exchanger. You find a used cross-flow exchanger (both fluids unmixed) in storage. It was
previously used to cool 136 kg/min of NH3 vapor from 200 C to 100 C using 320 kg/min
of water at 7 C; U was previously 480 W/m2. K . How much air can you cool with this
exchanger, using the same water supply, if U is approximately unchanged? (Actually,
you would have to modify U using the methods of Chapters 6 and 7 once you had the
new air flow rate, but that is beyond our present scope.)

Solution:
m& N = 136 kg/min
Thin = 200 C
Thout = 100 C
m& w = 320 kg/min
Tcin = 7 C
U = 480 W/m2.K.
Use c pN at 107 C = 7818 J/kg.K, since values at 127 C and above from table.
c pw at 7 C = 4201 J/kg.K

Cmax = m& wc pw = (320)(4201)/(60) = 22,405 W/K


Cmin = m& N c pN = (136)(7818)/(60) = 17,721 W/K
C min 17,721
= = 0.79
C max 22,405

Q = Cmin (Thin Tcin ) = Ch (Thin Thout )


Ch = Cmin = 17,721 J/kg.K
Q = (17,721)(200 7 ) = (17,721)(200 100)
= 0.52

From Fig. 3.17a, Cross-flow


C
= 0.52, min = 0.79
C max
then, NTU = 1.05
UA
NTU =
Cmin

1.05 =
(480)A
17,721
A = 38.765 m2.

For the new conditions:

36
3. HEAT EXCHANGER DESIGN

c pa at 105 C (average of 150 C and 60 C) = 1012 J/kg.K


Using the same water temperature is used as 7 C
Thin = 150 C
Thout = 60 C
Tcin = 7 C

C min = C h = m& a c pa = 1012m& a W/K


UA (480 )(38.765) 18.3866
NTU = = =
Cmin 1012m& a m& a
Q = Cmin (Thin Tcin ) = C min (Thin Thout ) = Ch (Thin Thout )
(Thin Tcin ) = (Thin Thout )
(150 7 ) = (150 60)
= 0.63
Cmax = m& wc pw = 22,405 W/K
C min = 1012m& a
C min 1012m& a
= = 0.04517 m& a
C max 22,405
Fig. 3.17a, cross-flow
C min
= 0.04517 m& a
C max
18.3866
NTU =
m& a
= 0.63

Tabulation of trial and error method:


m& a C min NTU NTU (graph)
C max
20 0.9034 0.91933 1.4
15 0.67755 1.22577 1.143
16 0.72272 1.1492 1.2

By interpolation:
x 1.22577 x 1.143
=
1.1492 1.2257 1.2 1.143
1.342( x 1.22577 ) = x 1.143
x = 1.19
Then:

37
3. HEAT EXCHANGER DESIGN

1.19 1.143
m& a = (16 15) + 15 = 15.8 kg/s 950 kg/min
1.2 1.143

3.25 A one tube-pass, one shell-pass, parallel-flow, process heat exchanger cools 5 kg/s of
gaseous ammonia entering the shell side at 250 C and boils 4.8 kg/s of water in the tubes.
The water enters subcooled at 27 C and boils when it reaches 100 C. U = 480 W/m2.K
before boiling begins and 964 W/m2.K there-after. The area of the exchanger is 45 m2,
and hfg for water is 2.257 x 106 J/kg. Determine the quality of the water at the exit.

Solution: Parallel Flow:


m& a = 5 kg/s
Thin = 250 C
m& w = 4.8 kg/s
Tcin = 27 C
From Appendix A, extrapolated.
Specific heat of gaseous ammonia at 250 C, c pa = 2524 J/kg.K

Specific heat of water at 63.5 C, c pw = 4188 J/kg.K

Boiling water at 100 C, U1 = 480 W/m2.K


Tcout = 100 C
Q1 = m& wc pw (Tcout Tcin )
Q1 = (4.8)(4188)(100 27)
Q1 = 1,467,475 W
Q1 = U 1 A 1( LMTD1 )

LMTD1 = in
(Th Tcin ) (Thout Tcout )
T T
ln hin cin
Th Tc
out out

Q1 = m& a c pa (Thin hhout )


1, 467,475 = (5)(2524 )(250 Thout )
Thout = 133.72 C

LMTD1 =
(250 27 ) (133.72 100) = 100.2 C
250 27
ln
133.72 100
Q1 = U 1 A 1( LMTD1 )
1,467,475 = (480 ) A 1(100.2 )

38
3. HEAT EXCHANGER DESIGN

A 1 = 30.5 m2.

Total Area, A = 45 m2.

Remaining area for evaporation at 100 C.


A 2 = A A1
A 2 = 45 30.5 = 14.5 m2.

At evaporation, U2 = 964 W/m2.K.

Thin =133.72 C

Specific heat of gaseous ammonia at 133.72 C


c pa = 2297 J/kg.K, from Appendix A

Q2 = Cmin (Thin Tcin ) = m& w h fg ( x )


C min = m& a c pa =(5)(2297) = 11,485 W/K
Tcin = 100 C
hfg = 2.257 x 106 J/kg
= lim = 1 e NTU
C max

U 2 A2 (964)(14.5)
NTU = = = 1.2171
C min 11485
= 1 e 1.2171 = 0.704
Q2 = Cmin (Thin Tcin ) = m& w h fg ( x )
Q2 = (0.704 )(11485)(133.72 100 ) = (4.8)(2.257 106 )( x )
x = 0.025 or 2.5 % vapor

3.26 0.72 kg/s of superheated steam enters a cross-flow heat exchanger at 240 C and leaves at
120 C. It heats 0.6 kg/s of water entering at 17 C. U = 612 W/m2.K. By what percentage
will the area differ if a both-fluids-unmixed exchanger is used instead of a one-fluid-
unmixed exchanger?

Solution:
m& s = 0.72 kg/s
Thin = 240 C
Thout = 120 C
m& w = 0.60 kg/s
Tcin = 17 C
Specific heat of superheated steam at 180 C, c ps = 1976 J/kg.K, Table A.6

39
3. HEAT EXCHANGER DESIGN

Specific heat of water at 17 C, c pw = 4187 J/kg.K.


Solving for Tcout .
Q = m& s c ps (Thin Thout ) = m& wc pw (Tcout Tcin )
(0.72 )(1976 )(240 120 ) = (0.60 )(4187 )(T c out 17 )
Tcout = 85 C

LMTD =
(T hin Tcout ) (Thout Tcin )
=
(240 85) (120 17) = 127.23 C
T T 240 85
ln hin cout ln
Th Tc 120 17
out in
Ttout Ttin
P=
Tsin Ttin
Tsin Tsout
R=
Ttout Ttin
Ttout = 120 C
Ttin = 250 C
Tsin = 17 C
Tsout = 85 C
120 85
P= = 0.54
120 240
17 85
R= = 0.57
120 240
Q = m& s c ps (Thin Thout ) = (0.72 )(1976 )(240 120 ) = 170,727 W
For cross-flow, both fluid unmixed, Fig. 3.14c.
F1 = 0.95
Q = UA 1 F1 ( LMTD )
170,727 = (612 ) A 1(0.95)(127.23)
A 1 = 2.308 m2.
For cross-flow, one fluid unmixed, Fig. 3.14d
F2 = 0.933
Q = UA 2 F2 (LMTD )
170,727 = (612 ) A 2 (0.933)(127.23)
A 2 = 2.350 m2.
A A1
% area = 2 (100%) = 2.308 2.350 (100%) = - 1.8 %
A2 2.350

3.27 Compare values of F from Fig. 3.14c and Fig. 3.14d for the same conditions of inlet and
outlet temperatures. Is the one with higher F automatically the more desirable exchanger?
Discuss.
40
3. HEAT EXCHANGER DESIGN

Discussion:

At given the same conditions of inlet and outlet temperatures, value of F from Fig. 3.14c is
higher than values from Fig. 3.14d. Higher values of F automatically will be the more desirable
heat exchanger because it will give lesser heat transfer area, A.

C min
3.28 Compare values of for the same NTU and in parallel and counterflow heat
C max
exchangers. Is the one with higher automatically the more desirable exchanger?
Discuss.

Discussion:
Reference to Fig. 3.16, -value for counterflow gives higher values than parallel-flow for the
C
same NTU and min . Higher values of will automatically be the more desirable heat
C max
exchanger because it will give higher heating capacity, Q = C min (Thin Tcin ) .

3.29 The irreversibility rate of a process is equal to the rate of entropy production times the
lowest absolute sink temperature accessible to the process. Calculate the irreversibility
(or lost work) for the heat exchanger in Example 3.4. What kind of configuration would
reduce the irreversibility given the same end temperatures?

Solution:
From Ex. 3.4, two-shell pass, four-tube passes oil cooler.
Oil: m& o = 5.795 kg/s
Thin = 181 C
Th out = 38 C
Water:
Tcin = 32 C
Tc out = 49 C
c poil = 2282 J/kg.K
U = 416 W/m2.K
Using P = 0.959, R = 0.119, F = 0.92
A = 121.2 m2.

Solving for irreversibility:


T T
S&un = m& o c po ln hout + m& wc pw ln cout
Th Tc
in in
Specific heat of water at 40 C, c pw = 4180 J/kg.K
Q = m& o c po (Thin Thout ) = m& wc pw (Tcout Tcin )
41
3. HEAT EXCHANGER DESIGN

(5.795)(2282)(181 38) = m& (4180)(49 32)


w

m& w = 26.612 kg/s


38 + 273 49 + 273
S&un = (5.795)(2282 ) ln + (26.612 )(4180 ) ln = 1031 W/K
181 + 273 32 + 273
Irreversibility = Tsink S&un = (32 + 273)(1031) = 314,455 W

Any configuration will give the same irreversibility for the given the same end temperatures.

3.30 Plot Toil and TH 2 O as a function of position in a very long counterflow heat exchanger
where water enters at 0 C, with C H 2O = 460 W/K, and oil enters at 90 C, with Coil = 920
W/K, U = 742 W/m2.K, and A = 10 m2. Criticize the design.

Solution:

For counterflow case:


C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
C max C max
UA
NTU =
Cmin
C min = C H 2O = 460 W/K
C max = Coil = 920 W/K
Thin = 90 C
Tcin = 0 C
UA (742)(10 )
NTU = = = 16.13
C min 460
C min 460
= = 0.5
C max 920
1 exp[ (1 0.5)(16.13)]
= = 0.9997
1 (0.5) exp[ (1 0.5)(16.13)]
Q = Cmin (Thin Tcin ) = (0.9997 )(460 )(90 0) = 41,287.6 W
Q =C H 2 O (Tcout Tcin )
41,387.6 = (460 )(TH 2O 0)
TH 2 O = 89.973 C
Q =Coil (Thin Thout )
42
3. HEAT EXCHANGER DESIGN

41,387.6 =(920 )(90 Toil )


Toil = 45.014 C 45 C

Plot:

UA
Since NTU = > 5 , the area of 10 m2 is very large.
Cmin

3.31 Liquid ammonia at 2 kg/s is cooled from 100 C to 30 C in the shell side of a two shell-
pass, four tube-pass heat exchanger by 3 kg/s of water at 10 C. When the exchanger is
new, U = 750 W/m2.K. Plot the exit ammonia temperature as a function of the increasing
tube fouling factor.

Solution:
U new = 750 W/m2.K
m& a = 2 kg/s
Thin = 100 C
Thout = 30 C
m& w = 3 kg/s
Tcin = 10 C
Specific heat of liquid ammonia at 65 C, c pa = 5348 J/kg.K
Specific heat of water at 10 C, c pw = 4196 J/kg.K
Cmin = Ch = m& a c pa = (2)(5348) = 10,696 W/K
Cmax = Cc = m& wc pw = (3)(4196) = 12,588 W/K
1 1
Rf =
U old U new
For new unit: two-shell-pass, four-tube-pass
Q = Ch (Thin Thout ) = Cc (Tcout Tcin )
43
3. HEAT EXCHANGER DESIGN

(10,696)(100 30 ) = (12,588)(T cout 10 )


Tcout = 69.48 C

LMTD =
(T hin Tcout ) (Thout Tcin )
=
(100 69.48) (30 10) = 24.89 C
T T 100 69.48
ln hin cout ln
Th Tc 30 10
out in
Tsin = 100 C
Tsout = 30 C
Ttin = 10 C
Ttout = 69.48 C

Ttout Ttin
P=
Tsin Ttin
Tsin Tsout
R=
Ttout Ttin
69.48 10
P= = 0.66
100 10
100 30
R= = 1.18 > 1
69.48 10

Use Reciprocal Rule:


P = PR = (0.66)(1.18) = 0.78
R = 1/R = 1/1.18 = 0.85
From Fig. 3.14b, F = 0.60

Q = Ch (Thin Thout ) = UAF (LMTD )


(10,696)(100 30) = (750)A(0.60)(24.89)
A = 66.85 m2.

For old unit:


1 1
Rf =
U old U new
U new = 750 W/m2.K
1 1 1
= Rf + = Rf +
U old U new 750
750
U old =
750 R f + 1

44
3. HEAT EXCHANGER DESIGN

750
(66.85)
U old A 750 R f + 1
NTU = =
C min 10,696
4.6875
NTU =
750 R f + 1
Cmin 10,696
= = 0.85
C max 12,588

C min
Fig. 3,17d, Tabulation for = 0.85
C max
NTU
5 0.778
4 0.760
3 0.720
2 0.66

By curve fitting:
= 0.4761 + 0.1129(NTU ) 0.0105(NTU )
2
, for 5 > NTU > 2
Then,
Q = Cmin (Thin Tcin ) =C h (Thin Thout )
C min = Ch
Thout = Thin (Thin Tcin )
Thout = 100 (100 10) = 100 90
[
Thout = 100 90 0.4761 + 0.1129( NTU ) 0.0105( NTU )
2
]
Thout = 57.151 10.161( NTU ) + 0.945( NTU )
2

2
4.6875
Thout = 57.151 10.161 + 0.945 4.6875
750 R + 1
750 R f + 1 f
47.63 20.764
Thout = 57.151 +
750 R f + 1 (750 R f + 1)
2

Tabulation of Values:
R f , m2.K/W Thout , C
0 30
0.0005 33.5
0.0010 36.7
0.0015 39.3

Plot:
45
3. HEAT EXCHANGER DESIGN

3.32 A one shell-pass, two tube-pass heat exchanger cools 0.403 kg/s of methanol from 47 C
to 7 C on the shell side. The coolant is 2.2 kg/s of Freon 12, entering the tubes at 33 C
with U = 538 W/m2.K. A colleague suggests that this arrangement wastes Freon. She
thinks you could do almost as well if you cut the Freon flow rate all the way down to 0.8
kg/s. Calculate the new methanol outlet temperature that would result from this flow rate,
and evaluate her suggestion.

Solution:

First condition,
m& m = 0.403 kg/s
Thin = 47 C = Tsin
Thout = 7 C = Tsout

46
3. HEAT EXCHANGER DESIGN

m& f = 2.2 kg/s


Tcin = -33 C = Ttin
U = 538 W/m2.K

Specific heat of Methanol at 27 C, c pm = 2534 J/kg.K


Specific heat of Freon at 33 C, c pf = 1100 J/kg.K

Q = mm c pm (Thin Thout ) = m f c pf (Tcout Tcin )


(0.403)(2534)(47 7 ) = (2.2)(1100 )[T cout ]
( 33)
Tcout = -16.12 C = Ttout
Q = (0.403)(2534)(47 7 ) = 40,848 W
Q = UAF (LMTD )

LMTD = in
(Th Tcout ) (Thout Tcin ) = [47 ( 16.12)] [7 ( 33)] = 50.684 C
T T 47 ( 16.12 )
ln hin cout ln
Th Tc
out in
7 ( 33)
Tt Ttin 16.12 ( 33)
P = out = = 0.211
Tsin Ttin 47 ( 33)
Tsin Tsout 47 7
R= = = 2.37 > 1
Ttout Ttin 16.12 ( 33)
Use Reciprocal Rule:
P = PR = (0.211)(2.37) = 0.50
R = 1/R = 1/(2.37) = 0.42
From Fig. 3.14b, F = 0.95
Q = UAF (LMTD )
40,848 = (538) A(0.95)(50.684 )
A = 1.577 m2.

Second Condition: U = 538 W/m2.K, A = 1.577 m2.


m& m = 0.403 kg/s
c pm = 2534 J/kg.K
m& f = 0.8 kg/s
c pf = 1100 J/kg.K
Thin = 47 C
Tcin = -33 C
Ch = m& m c pm = (0.403)(2534) = 1021.2 W/K
Cc = m& f c pf = (0.80)(1100) = 880 W/K

47
3. HEAT EXCHANGER DESIGN

C min = Cc
Cmax = Ch
C min 880
= = 0.86
C max 1021.2
UA (538)(1.577 )
NTU = = = 0.964
Cmin 880
Fig. 3.17c, one shell-pass, two-tube pass heat exchanger,
= 0.48
Q = Cmin (Thin Tcin ) = (0.48)(880 )[47 ( 33)] = 33,792 W

Q 33,792
Thout = Thin = 47 = 13.9 C
Ch 1021.2

Check for Tcout :


Q 33,792
Tcout = Tcin + = 33 + = 5.4 C
Cc 880

New Methanol outlet temperature, Thout = 13.9 C > 7 C. Therefore her suggestion will not attain 7
C methanol temperature.

3.33 The factors dictating the heat transfer coefficients in a certain two shell-pass, four tube-
pass heat exchanger are such that U increase as (m& shell ) . The exchanger cools 2 kg/s of
0.6

air from 200 C to 40 C using 4.4 kg/s of water at 7 C, and U = 312 W/m2.K under these
circumstances. If we double the airflow, what will its temperature be leaving the
exchanger?

Solution:
m& a = m& shell = 2 kg/s
Thin = 200 C = Tsin
Thout = 40 C = Tsout
m& w = 4.4 kg/s
Tcin = 7 C = Ttin
U = 312 W/m2.K
U (m& shell )
0. 6

U = k (m& shell )
0.6

312 = k (2.0)
0.6

k = 205.84
U = 205.84(m& shell ) = 205.84(m& a )
0.6 0. 6

48
3. HEAT EXCHANGER DESIGN

Specific heat of air at 120 C, c pa = 1013 J/kg.K


Specific heat of water at 7 C, c pw = 4201 J/kg.K

First condition:
Q = m& a c pa (Thin Thout ) = m& w c pw (Tcout Tcin )
(2 )(1013)(200 40 ) = (4.4)(4201)(T c out 7)
Tcout = 24.55 C = Ttout
Q = (2 )(1013)(200 40 ) = 324,160 W
Q = UAF (LMTD )

LMTD = in
(Th Tcout ) (Thout Tcin ) = (200 24.55) (40 7) = 85.256 C
T T 200 24.55
ln hin cout ln
Th Tc 40 7
out in

Tt Ttin 24.55 7
P = out = = 0.090933
Tsin Ttin 200 7
Tsin Tsout
200 40
R= = =9.11681 > 1
Ttout Ttin 24.55 7
Use Reciprocal Rule:
P = PR = (0.090933)(9.11681) = 0.83
R = 1/R = 1/(9.11681) = 0.11
From Fig. 3.14, two shell-pass, four tube-pass heat exchanger
F = 0.975
Q = UAF (LMTD )
324,160 = (312)(A)(0.975)(85.256)
A = 12.5 m2.

Second Condition:
m& a = m& shell = 2(2 kg/s) = 4 kg/s
Thin = 200 C
m& w = 4.4 kg/s
Tcin = 7 C
U = 205.84(m& shell ) = 205.84(m& a )
0.6 0. 6

U = 205.84(4.0) = 472.9 W/m2.K


0. 6

A = 12.5 m2.
Ch = m& a c pa = (4)(1013) = 4052 W/K
Cc = m& wc pw = (4.4)(4201) = 18,485 W/K
Cmin = Ch = 4052 W/K
Cmax = Cc = 18,485 W/K

49
3. HEAT EXCHANGER DESIGN

Cmin 4052
= = 0.22
C max 18485
UA (472.9 )(12.5)
NTU = = = 1.46
C min 4052
Fig. 3.17d, two shell-pass, four tube-pass heat exchanger
= 0.72

Q = Cmin (Thin Tcin )


Q = (0.72 )(4052 )(200 7 ) = 563,066 W

Q 563,066
Thout = Thin = 200 = 61.0 C
Ch 4052

3.34 A flow rate of 1.4 kg/s of water enters the tubes of a two-shell-pass, four-tube-pass heat
exchanger at 7 C. A flow rate of 0.6 kg/s of liquid ammonia at 100 C is to be cooled to 30
C on the shell side; U = 573 W/m2.K. (a) How large must the heat exchanger be? (b) How
large must it be if, after some months a fouling factor of 0.0015 will build up in the tubes,
and we still want to deliver ammonia at 30 C? (c) If we make it large enough to
accommodate fouling, to what temperature will it cool the ammonia when it is new? (d)
At what temperature does water leave the new, enlarged exchanger?

Solution:

(a) Two-shell-pass, four-tube-pass

m& w = 1.4 kg/s


Tcin = Ttin = 7 C
m& a = 0.6 kg/s
Thin = Tsin = 100 C
Thout = Tsout = 30 C
U = 573 W/m2.K

Specific heat of liquid ammonia at 65 C, c pa = 5348 J/kg.K


Specific heat of water at 7 C, c pw = 4201 J/kg.K

Ch = Cmin = m& a c pa = (0.6)(5348) = 3208.8 W/K


Cc = Cmax = m& wc pw = (1.4)(4201) = 5881.4 W/K
Q = C h (Thin Thout ) = (3208.8)(100 30) = 224,616 W
Q = UAF (LMTD )

50
3. HEAT EXCHANGER DESIGN

LMTD =
(Thin Tcout ) (Thout Tcin )
T T
ln hin cout
Th Tc
out in

Q = Cc (Tcout Tcin )
224.616 = (5881.4 )(Tcout 7 )
Tcout = 45.2 C = Ttout

LMTD =
(100 45.2) (30 7 ) = 36.63 C
100 45.2
ln
30 7
Tt Ttin 45.2 7
P = out = = 0.4108
Tsin Ttin 100 7
Tsin Tsout
100 30
R= = = 1.8325 > 1
Ttout Ttin 45.2 7
Use Reciprocal Rule:
P = PR = (0.4108)(1.8325) = 0.75
R = 1/R = 1/(1.8325) = 0.55
From Fig. 3.14, two shell-pass, four tube-pass heat exchanger
F = 0.915
Q = UAF (LMTD )
224,616 = (573)(A)(0.915)(36.63)
A = 11.7 m2.

(b) if R f = 0.0015

1 1
= Rf +
U old U new
1 1
= 0.0015 +
U 573
U = 308.15 W/m2.K
Q = UAF (LMTD )
224,616 = (308.15)(A)(0.915)(36.63)
A = 21.75 m2.

(c) if A = 21.75 m2, U = 573 w/m2.K

C min = 3208.8 W/K


C max = 5881.4 W/K
Thin = 100 C

51
3. HEAT EXCHANGER DESIGN

Tcin = 7 C
C min 3208.8
= = 0.55
C max 5881.4
UA (573)(21.75)
NTU = = = 3.9
C min 3208.8
Fig. 3.17d, two shell-pass, four tube-pass heat exchanger
= 0.85

Q = Cmin (Thin Tcin )


Q = (0.85)(3208.8)(100 7 ) = 253,656 W

Q 253,656
Thout = Thin = 100 = 21 C
Ch 3208.8

Q 253,656
(d) Tcout = Tcin + =7 = 50 C
Cc 5881.4

3.35 Both Cs in a parallel-flow heat exchanger are equal to 156 W/K, U = 327 W/m2.K and A
= 2 m2. The hot fluid enters at 140 C and leaves at 90 C. The cold fluid enters at 40 C. If
both Cs are halved, what will be the exit temperature of the hot fluid?

Solution: Cmin = Cmax

For parallel flow, Eq. 3.20


C
1 exp 1 + min NTU
= Cmax
C
1 + min
Cmax
Cmin
=1
Cmax
if Cmin = Cmax = (1/2)(156 W/K) = 78 W/K
UA (327 )(2)
NTU = = = 8.385
C min 78
1 exp[ (1 + 1)(8.385)]
= = 0.5
1+1
Q = Cmin (Thin Tcin ) = (0.5)(78)(140 40) = 3900 W
Q 3900
Thout =T hin = 140 = 90 C
C 78
This is still the same since NTU >5, remain the same.

52
3. HEAT EXCHANGER DESIGN

3.36 A 1.68 ft2 cross-flow heat exchanger with one fluid mixed condenses steam at
atmospheric pressure ( h = 2000 Btu/h.ft2.F) and boils methanol ( Tsat = 170 F and h =
1500 Btu/h.ft2.F) on the other side. Evaluate U (neglecting resistance of the metal),
LMTD, F, NTU, , and Q.

Solution:
Steam at atmosphere, Th = 212 F
Methanol, Tc = 170 F
Solving for U,
1 1 1
= +
U 2000 1500
U = 857 Btu/h.ft2.F
Solving for LMTD.
F = 1.0 for isothermal fluid.
Solving for NTU,
UA
NTU =
Cmin
but Cmin
NTU = 0
Solving for
lim = 1 e NTU
= C max
but NTU = 0
= 1.0

C min
3.37 Eqn. (3.21) is troublesome when = 1.0 . Develop a working equation for in this
C max
case. Compare it with Fig. 3.16.

Solution:
Eq. (3.21)
C
1 exp 1 min NTU
= Cmax
C C
1 min exp 1 min NTU
Cmax C max
C min
if = 1.0
C max
0
=
0
LHospital rule.

53
3. HEAT EXCHANGER DESIGN

C
1 exp 1 min NTU
Lim = CLim Cmax
C min
0 min 0
C C
C max C max
1 min exp 1 min NTU
Cmax Cmax
Cmin
1 exp 1 NTU
C Cmax Cmin =1
min C max

= C max
Cmin C
1 exp 1 min NTU
C C Cmax Cmin =1
min max C max
C max
C
( NTU )( 1) exp 1 min NTU
Cmax Cmin =1
C max
=
C C C
( NTU ) min ( 1) exp 1 min NTU exp 1 min NTU
Cmax Cmax Cmax Cmin =1
Cmax

C
NTU exp 1 min NTU
Cmax Cmin =1
C max
=
Cmin C
NTU 1 exp 1 min NTU
Cmax Cmax Cmin =1
C max

NTU
=
Cmin
NTU + 1
C max Cmin =1
C max

NTU
=
NTU + 1

Comparison Table:
NTU NTU Fig. 3.16,
=
NTU + 1
5 0.83 0.83
4 0.8 0.8
3 0.75 0.75
2 0.67 0.67

54
3. HEAT EXCHANGER DESIGN

3.38 The effectiveness of a cross-flow exchanger with neither fluid mixed can be calculated
NTU 0.22
from the following approximate formula: = 1 exp [exp ( NTU 0.78 r ) 1]
r
C
where r min . How does this compare with correct values?
Cmax

Solution:
Fig. 3.17a

Comparison
C
r min = 1.0
Cmax
NTU (approximate) (Fig. 3.17a)
5 0.749 0.75
4 0.723 0.72
3 0.684 0.68
2 0.615 0.62
1 0.469 0.47

Cmin
r = 0.75
Cmax
NTU (approximate) (Fig. 3.17a)
5 0.828 0.83
4 0.800 0.800
3 0.755 0.75
2 0.675 0.67
1 0.505 0.51

Therefore it gives very near values to two digits.

Cmin
If r =0
Cmax
The term
NTU 0.22 0
[exp( NTU 0. 78
r ) 1] =
r 0
Use LHospital rule:

[exp( NTU 0. 78
r ) 1]NTU 0.22 {[exp( NTU 0.78 r ) 1]NTU 0.22 }r =0
Lim = r
r 0
r
(r )
r r =0

55
3. HEAT EXCHANGER DESIGN

NTU 0.78 exp ( NTU 0.78 r )r =0


= = NTU 0.78
(1) r =0
Then
= 1 exp( NTU 0.78 )

Cmin
Comparison r =0, = 1 exp( NTU 0.78 )
Cmax

NTU (approximate) (Fig. 3.17a)


5 0.970 0.99
4 0.948 0.98
3 0.905 0.95
2 0.820 0.87
1 0.632 0.64

Cmin C
At lower values of r or r min 0 , this will not give correct values accurately.
Cmax Cmax

3.39 Calculate the area required in a two-tube pass, one-shell pass condenser that is to
condense 106 kg/h of steam at 40 C using water at 17 C. Assume that U = 4700 W/m2.K,
the maximum allowable temperature rise of the water is 10 C and hfg = 2406 kJ/kg.

Solution:
= 1 e NTU
UA
NTU =
Cmin
Specific heat of water at 17 C, c pw = 4187 J/kg.K
Th = 40 C
Tcin = 17 C
Tcout = 27 C
m& s = 106 kg/h
U = 4700 W/m2.K
hfg = 2406 kJ/kg

Q = Cmin (Tcout Tcin ) = m& s h fg


1
Cmin (27 17 ) = (10 6 ) (2406)
3600
C min = 66,833 W/K
Q = Cmin (Thin Tcin ) = m& s h fg
56
3. HEAT EXCHANGER DESIGN

1
(66,833)(40 17 ) = (106 ) (2406)
3600
= 0.4348
= 1 e NTU
0.4348 = 1 e NTU
NTU = 0.5706
UA
NTU =
Cmin

0.5706 =
(4700)A
66,833

A = 8.114 m2.

3.40 An engineer wants to divert 1 gal/min of water at 180 F from his car radiator through a
small cross-flow heat exchanger with neither flow mixed, to heat 40 F water to 140 F for
shaving when he goes camping. If he produces a pint per minute of hot water, what will
be the area of the exchanger and the temperature of the returning radiator coolant if U =
720 W/m2.K?

Solution:
Thin = 180 F
Tcin = 40 F
Tcout = 140 F

Specific heat of water at 180 F, c ph = 1.003 Btu/lb-F


Specific heat of water at 90 F, c pc = 0.998 Btu/lb-F
Density of water at 180 F, h = 60.56 lb/ft3.
Density of water at 140 F, c = 61.37 lb/ft3.

720
U = 720 W/m2.K = Btu/hr-ft2-F
5.6786
U = 126.8 Btu/hr-ft2-F

Solving for m& h

m& h = hVh
Vh = (1 gal/min)(231 in3/gal)(1 ft3 / 1728 in3)( 60 min/hr)
Vh = 8.0208 ft3/hr
m& h = (60.56)(8.0208) lb/sec = 485.74 lb/sec
57
3. HEAT EXCHANGER DESIGN

Solving for m& c

m& c = cVc
Vc = (1 pint/min)(0.125 gal/min)(231 in3/gal)(1 ft3 / 1728 in3)( 60 min/hr)
Vc = 1.0026 ft3/hr
m& c = (61.37)(1.0026) lb/sec = 61.53 lb/sec

Q = m& c c pc (Tcout Tcin )


Q = (61.53)(0.998)(140 40) = 6141 Btu/hr

Q = m& h c ph (Thin Thout )


6141 = (485.74)(1.003)(180 - Thout )
Thout = 167.4 F

LMTD =
(Thin Tcout ) (Thout Tcin )
T T
ln hin cout
Th Tc
out in

LMTD =
(180 140 ) (167.4 40 ) = 75.45 F
180 140
ln
167.4 40
Tt Ttin 140 40
P = out = = 0.71
Tsin Ttin 180 40
Tsin Tsout 180 167.4
R= = = 0.126
Ttout Ttin 140 40

Fig. 3.14c, Cross-flow exchanger, neither mixed, F = 0.965.

Q = UAF (LMTD )
6141 = (126.8)(A)(0.965)(75.45)
A = 0.665 ft2
And Thout = 167.4 F

3.41 In a process for forming lead shot, molten droplets of lead are showered into the top of a
tall tower. The droplets fall through air and solidify before they reach the bottom of the
tower. The solid shot is collected at the bottom. To maintain a steady state, cool air is
introduced at the bottom of the tower and warm air is withdrawn at the top. For a
particular tower, the droplets are 1 mm in diameter and at their melting temperature of
600 K when they are released. The latent heat of solidification is 850 kJ/kg. They fall
with a mass flow rate of 200 kg/hr. There are 2430 droplets per cubic meter of air inside
58
3. HEAT EXCHANGER DESIGN

the tower. Air enters the bottom at 20 C with a mass flow rate of 1100 kg/hr. The tower
has an internal diameter of 1m with adiabatic walls.

a. Sketch, qualitatively, the temperature distribution of the shot and the air along the
height of the tower.
b. If it is desired to remove the shot at a temperature of 60 C, what will be the
temperature of the air leaving the top of the tower?
c. Determine the air temperature at the point where the lead had just finishing
solidifying.
d. Determine the height that the tower must have in order to function as desired. The
heat transfer coefficient between the air and the droplets is h = 318 W/m2.K

Solution:

(a)

(b)

Specific heat of lead shot = c pl = 130 J/kg.K


Specific heat of air = c pa = 1008 J/kg.K
m& l = 200 kg/hr
h = 850 kJ/kg = 850,000 J/kg
[ ]
Q = m& l h + c pl (Thin Thout )
Thin = 600 K = 327 C
Thout = 60 C
1
Q = (200 ) [850,000 + 130(327 60)] = 49,151 W
3600
m& a = 1100 kg/hr
Tcin = 20 C
Q = m& a c pa (Tcout Tcin )

59
3. HEAT EXCHANGER DESIGN

1
49,151 = (1100 ) (1008)(Tcout 20)
3600
Tcout = 179.6 C

(c) Cooling required after solidification

Q2 = m& l c pl (Thin Thout )


1
Q2 = (200 ) (130 )(327 60) = 1928.33 W
3600
Q2 = m& a c pa (Tcout 2 Tcin )
1
1928.33 = (1100 ) (1008)(Tcout 2 20 )
3600
Tcout 2 = 26.3 C

(d) h = 318 W/m2.K

Q = UA(LMTD )
U = h = 318 W/m2.K
Solidification: Q1 = 49,151 1928.33 = 47,233 W

LMTD1 =
(T hin Tcout 2 ) (Thin Tcout1 )
T T
ln hin cout 2
Th Tc
in out1

LMTD1 =
(327 26.3) (327 179.6 ) = 215 C
327 26.3
ln
327 179.6
Q1 = UA 1(LMTD1 )
47,223 = (318)( A 1 )(215)
A 1 = 0.691 m2.

Cooling, Q2 = 1928.33 W

LMTD2 = in
(Th Tcout 2 ) (Thout Tcin )
T T
ln hin cout 2
Th Tc
out in

LMTD2 =
(327 26.3) (60 20 ) = 129.24 C
327 26.3
ln
60 20
60
3. HEAT EXCHANGER DESIGN

Q2 = UA 2 (LMTD2 )
1928.33 = (318) A 2(129.24)
A 2 = 0.047 m2.

A T = A 1+ A2 = 0.691 m2 + 0.047 m2 = 0.738 m2.


AT 0.738
No. of droplets = = = 234,913
(0.001)
2 2
d
234,913 droplets
VT = Volume of Tower = 3
= 96.67 m3.
2430 droplets / m
4VT 4(96.67 )
H = Height of Tower = = = 123 meters
(1)
2 2
D

-000-