Sie sind auf Seite 1von 2

SOFT K Fitting Guide BACK VERTEX DISTANCE CORRECTION TABLE

12 mm SP 12 mm 12 mm SP 12 mm 12 mm SP 12 mm

SOFT K
Base Curve Selection:
®
4.20 4.00 -3.82 9.78 8.75 -7.92 21.36 17.00 -14.12
4.48 4.25 -4.04 10.09 9.00 -8.12 22.15 17.50 -14.46
Keratoconus: 4.76 4.50 -4.27 10.40 9.25 -8.33 22.96 18.00 -14.80
5.04 4.75 -4.49 10.72 9.50 -8.53 23.78 18.50 -15.14
Select 7.6 Base Curve for initial diagnostic lens.
5.32 5.00 -4.72 11.04 9.75 -8.73 24.61 19.00 -15.47

Post-Surgical:
Select 7.9 Base Curve for initial diagnostic lens.
5.60
5.89
6.18
5.25
5.50
5.75
-4.94
-5.16
-5.38
11.36
12.01
12.67
10.00
10.50
11.00
-8.93
-9.33
-9.72
25.46
26.32
27.19
19.50
20.00
20.50
-15.80
-16.13
-16.45 Keratoconus
6.47
6.76
6.00
6.25
-5.60
-5.81
13.34
14.02
11.50
12.00
-10.11
-10.49
28.07
28.98
21.00
21.50
-16.77
-17.09 C o n t a c t L e n s
7.05 6.50 -6.03 14.71 12.50 -10.87 29.89 22.00 -17.41
NOTE: Allow Diagnostic Lens to settle for 10 minutes prior 7.34 6.75 -6.24 15.40 13.00 -11.25 30.82 22.50 -17.72
to analyzing movement. 7.64
7.94
7.00
7.25
-6.46
-6.67
16.11
16.83
13.50
14.00
-11.62
-11.99
31.77
32.73
23.00
23.50
-18.03
-18.33
No matter the surface
8.24
8.54
7.50
7.75
-6.88
-7.09
17.55
18.29
14.50
15.00
-12.35
-12.71
33.71
34.70
24.00
24.50
-18.63
-18.93 SOFT K® is the right fit
If Diagnostic Lens: 8.85 8.00 -7.30 19.04 15.50 -13.07 35.71 25.00 -19.23
9.16 8.25 -7.51 19.80 16.00 -13.42 37.75 26.00 -19.75
Moves more than ±1mm, select steeper Base Curve. 9.47 8.50 -7.71 20.57 16.50 -13.77 39.00 27.00 -21.25
Has less than ±0.5mm movement, select flatter Base
DIOPTER <=> MM CONVERSION TABLE
Curve.
mm dpt mm dpt mm dpt
Power Selection: 5.50 61.36 6.90 48.91 8.30 40.66
5.55 60.81 6.95 48.56 8.35 40.42
5.60 60.27 7.00 48.21 8.40 40.18
5.65 59.73 7.05 47.87 8.45 39.94
NOTE: Due to the unique design of the SOFT K, a tear 5.70 59.21 7.10 47.54 8.50 39.71
layer is formed; therefore it is necessary to allow the 5.75 58.70 7.15 47.20 8.55 39.47
diagnostic lens to equilibrate for at least 30 minutes before 5.80 58.19 7.20 46.88 8.60 39.24
5.85 57.69 7.25 46.55 8.65 39.02
an over-refraction is performed.
5.90 57.20 7.30 46.23 8.70 38.79
5.95 56.72 7.35 45.92 8.75 38.57
6.00 56.25 7.40 45.61 8.80 38.35
6.05 55.79 7.45 45.30 8.85 38.14
Start with a spherical over-refraction. If 20/30 or
6.10 55.33 7.50 45.00 8.90 37.92
acceptable vision is obtained, vertex over-refraction 6.15 54.88 7.55 44.70 8.95 37.71
6.20 54.44 7.60 44.41 9.00 37.50
as necessary and order initial lens.
6.25 54.00 7.65 44.12 9.05 37.29
6.30 53.57 7.70 43.83 9.10 37.09
SOFT K TORIC Lens: 6.35 53.15 7.75 43.55 9.15 36.89
6.40 52.73 7.80 43.27 9.20 36.68
If Cylinder Over-Refraction is performed, before 6.45 52.33 7.85 42.99 9.25 36.49
6.50 51.92 7.90 42.72 9.30 36.29
ordering a toric lens, it is recommended patient 6.55 51.53 7.95 42.45 9.35 36.10
wear a spherical lens with at least 20/40 VA for two 6.60 51.14 8.00 42.19 9.40 35.90
6.65 50.75 8.05 41.93 9.45 35.71
weeks. Re-verify the position of astigmatic axis for 6.70 50.37 8.10 41.67 9.50 35.53
consistency then order a SOFT K TORIC lens. 6.75 50.00 8.15 41.41 9.55 35.34
6.80 49.63 8.20 41.16 9.60 35.16
6.85 49.27 8.25 40.91 9.65 34.97
NOTE: The two fenestration holes in the SOFT K TORIC Distributed By
will be placed in the location of the 0°/180° axis of the lens.
There is also a dot at 270°.
www.soflexcontacts.com • soflex@soflexcontacts.com
Technical Information SOFT K Cleared by the FDA for the use of treatment for Innovative Lens Design
SOFT K Contact Lens is indicated for any Irregular Keratoconus, Post Surgical And High Astigmatic Patients
Corneal Astigmatism due to Keratoconus and many
A Soft Contact Lens specifically designed to fit irregular
Post Surgical conditions.
corneas distorted by disease, surgery or injury.
Easy to Fit - Easy to Wear Material: Xylofilcon A
SOFT K is an excellent alternative for Definitive (Silicone Hydrogel)
comfortable Keratoconus Contact Lens options. Water: 67%
Unique Features 74% Definitive
Oxygen: 29 DK
Generous Thickness Across Central Optical Zone –
57 DK Definitive
provides enhanced acuity due to the tear layer formed
much like a GP lens. Lens Parameters
• Two Fenestrated Holes – allows air to escape from Base Curve: 7.0 7.3 7.6 7.9 8.2
behind the lens providing improved equilibration, Powers: +10.00 to -20.00DS
visual stability and increased DK value.
Diameter: 14.2 mm
• Double Lenticularization – decreases lens mass and
increases comfort. Toric Designs Available:
Cylinder: Up to -7.00DS
• 67% High Water Content & Oxygen Permeability
29 DK - performs well for ocular health. Axis: Any
• 74% Definitive High Water Content & Oxygen Permeability
57 DK - performs well for ocular health. NOTE: The two fenestration holes in the SOFT K TORIC
will be placed in the location of the 0°/180° axis of the lens.
Diagnostic Fitting Sets Available
There is also a dot at 270°.

Three Lens Fitting Set


BC 7.3 7.6 7.9 Soft K 67%
Five Lens Fitting Set 12 monthly use
BC 7.0 7.3 7.6 7.9 8.2
Soft K Definitive
SOFT K Diagnostic Fitting is necessary to observe 3 monthly use
proper lens to cornea relationship facilitating
acceptable movement / position and determining the
expected tear layer power compensation.
The thicker Central Optic Zone must settle across the
visual axis before the final Rx can be determined.
www.soflexcontacts.com