SUMMARY
Sub Head A Equipment
Total
Service tax
Total
Service Tax
Total
Rate in words :-
Page 1
BILL OF QUANTITIES
Part-A : Equipment
Page 2
S. No. Description Unit Qty. Rate Amount
2.1.2 8 HP (Ductable) High Static (6.6 TR) Nos 1 -
RATE IN WORDS
2.1.3 5 HP (ductable) High Static (4.1 TR) Nos 2 -
RATE IN WORDS
2.1.4 3 HP (ductable) High Static (2.4 TR) Nos 2 -
RATE IN WORDS
2.1.5 1.5 HP (ductable) High Static (1.2 TR) Nos 4 -
RATE IN WORDS
2.2 Hiwall units
2.2.1 0.8 HP (.60 TR) Nos 1 -
RATE IN WORDS
2.3 4 way compact Cassette Type to be fitted in 2 x 2 tile.
2.3.1 3 HP ( normal 3' x 3' size) (2.4 TR) Nos 5 -
RATE IN WORDS
2.3.2 2 HP (compact 2' x 2' size) (1.60 TR) Nos 64 -
RATE IN WORDS
2.3.3 1.5 HP (compact 2' x 2' size) (1.2 TR) Nos 165 -
RATE IN WORDS
2.3.3 1 HP (compact 2' x 2' size) (.80 TR) Nos 7 -
RATE IN WORDS
3 Corded remote controls Nos. 237 -
RATE IN WORDS
4 Cordless remote control Nos 5 -
RATE IN WORDS
5 Supply Installation Testing and Commissioning of
Treated Fresh Air Units
Supply, installing, testing and commissioning of factory
built Ceiling suspended double skin type Treated Fresh air
handling units made of 40-50 mm thick panels consisting
of G.I. Casing of thickness 0.63 mm outside layer 0.63
mm thickness inside layer with polyurethene foam (PUF)
insulation of density not less than 38 Kg/Cum factory
injected between them by injection molding machine,
complete with blower section with blower suitable for
static pressure as detailed below, cooling coil section
with aluminum finned copper tubes (tube thickness not
less than 0.5mm) VRV cooling coil( 10 HP), filter
sections with washable synthetic type air pre-filters, belt
drive package with TEFC drive motor suitable for 220+-
6% volts, 50 HZ, 1 Phase, A.C. supply, drain connections,
stainless steel drain pan
5.1 1800 CFM/ 15 mm External static / 6 Row deep 18 HP Nos 3 -
cooling coil.
RATE IN WORDS
5.2 1500 CFM/ 15 mm External static / 6 Row deep 16 HP Nos 1 -
cooling coil.
RATE IN WORDS
6 Supply Installation Testing and Commissioning of
Required AHU kit for connecting the Cooling coils with
the VRF Outdoor unit complete with expansion valve,
Sensors, wired remote controller and PCB etc. as
required.
6.1 18/16 HP Sets 4 -
RATE IN WORDS
Page 3
S. No. Description Unit Qty. Rate Amount
7 Supply, installation, testing and commissioning of 5 star
rating spilt units including stand, refrigerant pipe, cable,
gas charging etc.
7.1 2 TR No 6 -
RATE IN WORDS
7.2 1.5 TR No 6 -
RATE IN WORDS
8 Pressurization fan
Supply Installation, Testing and commissioning of SISW
blowers of following capacity complete with Blower,
Motor, foundation, Foundation bolts, Belt Drive Package,
spring type Vibration isolation pads, canvass etc.
8.1 2000 CFM, 25 mm static Nos 2 -
RATE IN WORDS
Sub Total Part A ( EQUIPMENT) -
Part-B : Lowside
Page 4
S. No. Description Unit Qty. Rate Amount
RATE IN WORDS
3.11 9.5 mm O.D.(insulation : 13 mm) Rmt 580 -
RATE IN WORDS
3.12 6.4 mm O.D.(insulation : 13 mm) Rmt 1700 -
RATE IN WORDS
4 Supply, Installation, testing and commissioning of UPVC
piping complete with fittings, supports as per
specifications
4.1 80 mm dia Rmt 95 -
RATE IN WORDS
4.2 65 mm dia Rmt 160 -
RATE IN WORDS
4.3 50 mm Dia Rmt 25 -
RATE IN WORDS
4.4 40 mm Dia Rmt 25 -
RATE IN WORDS
4.5 32 mm Dia Rmt 25 -
RATE IN WORDS
4.6 25 mm Dia Rmt 2320 -
RATE IN WORDS
5 Supply, installation, testing and commissioning of factory
fabricated Rectangular sheet metal ducting complete with
supports, dampers etc. as per IS 655 and approved
drawing and as per specifications of below gauges:
5.1 26 Gauge Sqm. 120 -
RATE IN WORDS
5.2 24 Gauge Sqm. 400 -
RATE IN WORDS
5.3 22 Gauge Sqm. 80 -
RATE IN WORDS
6 Supply, installation, testing and commissioning of closed
cell Nitrile rubber insulation of following thickness
applied with Proper adhesive and sealed with 75 mm wide
BOPP Tape on all longitudinal/ transverse joints complete
as per specifications.
9 mm thick on ducts in conditioned space Sqm. 550 -
RATE IN WORDS
7 Supply, installation, testing and commissioning of 32 kg /
m3 density fiberglass insulation in the form of 12 mm
Thick Fiber Glass boards, 2 Layers of Tissue paper
finished with 28 gauge perforated Aluminum sheet with
nuts, bolts complete as per specifications.
12 mm thickness acoustic lining Sqm. 650 -
RATE IN WORDS
8 Supply, installation, testing and balancing of powder Sqm. 1.5 -
coated extruded aluminum square shape ceiling diffusers
with removable core and anti smudge ring & aluminum
volume control dampers as per approved drawings and
specifications.
RATE IN WORDS
Page 5
S. No. Description Unit Qty. Rate Amount
9 Supply, installation, testing and balancing of Powder Sqm 1.5 -
coated extruded aluminum construction square shape
return air diffusers with removable core, anti smudge ring
& without volume control damper as per approved
drawings and specifications.
RATE IN WORDS
10 Supply, Installation, Testing and Balancing of Powder Sqm 1.5 -
coated extruded aluminum construction Grilles as per
approved drawings and specifications. Quoted price shall
be without volume control damper at the location of air
collar
RATE IN WORDS
11 Supply, Installation, Testing and Balancing of Powder Sqm 12 -
coated extruded aluminum construction Linear Grilles as
per approved drawings and specifications. Quoted price
shall be without volume control damper at the location of
air collar
RATE IN WORDS
12 Supplying & fixing of opposed blade aluminum Sqm. 5 -
construction volume control dampers in duct collars as
per approved drawings and as per approved drawings and
specifications.
RATE IN WORDS
13 Providing and fixing Fire retardant non porous double Nos. 8 -
layer flexible canvass connection between each indoor
unit and duct as per approved drawings and specifications.
RATE IN WORDS
14 Supplying & fixing of opposed blade GSS construction Sqm. 1.5 -
volume control dampers in duct as per approved drawings
and as per approved drawings and specifications.
RATE IN WORDS
15 Supplying & fixing of Fresh air Grill with Bird screen as Sqm. 1.5 -
per approved drawings and as per approved drawings and
specifications.
RATE IN WORDS
16 Cable Tray for Running Copper Refrigerant Piping upto Rmt 1000 -
300 mm wide.
RATE IN WORDS
17 Control & Transmission Wiring
Providing & fixing control cum transmission wiring of 2 Rmt 4450 -
core x 1.5 sq. mm. copper in PVC conduits between
indoor and outdoor unit.
RATE IN WORDS
18 Controller Wiring
Providing & fixing control wiring of 2 core x 1.5 sq mm Rmt 4450 -
copper between indoor units and their wired remote.
RATE IN WORDS
Sub Total Part B (LOWSIDE) 250,000.00
Part-C : Electrical
1 Control Panel
Page 6
S. No. Description Unit Qty. Rate Amount
Designing, fabricating, transporting to site, installing,
testing and commissioning of floor mounted, self
supported, compartmentalized LT cubical pattern
(Extendable Type) metal clad switch board, fabricated
from 2mm (14 G) thick CRCA sheet steel suitable for 31
MVA rupturing capacity at 415 V, 3 phase, 4 wire, 50 HZ
AC supply and equipped with PVC sleeved aluminum bus
bars of specified rating and following switch gears inter
connected by PVC sleeved solid conductors, including 7-
tank cleaning, degreasing, phosphating process and
treatment of panel with anti-corrosive zinc based primer
paint and finally powder coating the panel, complete with
earthing terminals, cable and bus bar alleys and hoisting
hooks as required. The LT panel will comprise ACBs and
MCCBs as described below for incoming and outgoing
power supplies.
INCOMING MCCB FEATURES
All the incoming circuit breakers of panels shall consist of
following accessories:
i. 0-500 V range voltmeter 144 x 144 mm size with
selector switch and back up fuses. : 1 Set.
ii. Suitable range of ammeter 144 x 144 mm size with
selector switch and CTs as mentioned in schedule. : 1 Set.
Page 7
S. No. Description Unit Qty. Rate Amount
63A, TPN MCCB with 0-60 A ammeter 100 / 5A Current
Transformer & selector switch, indication lamp with
MCB for ON status of equipment. Overload and under
voltage protection device, ELCB of minimum 300 mA
current sensitivity, Time delay relay, Single phase
preventer, phase reversal protection : 18 nos for ODUs
Spare feeders 4 Nos
40A, TPN MCCB with 0-60 A ammeter 100 / 5A Current
Transformer & selector switch, indication lamp with
MCB for ON status of equipment. Overload and under
voltage protection device, ELCB of minimum 300 mA
current sensitivity, Time delay relay, Single phase
preventer, phase reversal protection : 10 nos for Indoor
units
Note : we have considered 2 ODU per set of 40 HP .
Incase the ODU configuration has more no of ODUs the
panel shall be suitably modified at no extra cost. The
bidder should ensure the same.
Interlocking with singal /communication wire as per
recommendation of VRF OEM .
Page 8
S. No. Description Unit Qty. Rate Amount
1 Supply, installation, testing and commissioning of Single
skin Construction FAN BOX with GSS of minimum 1.6
mm Thickness rigidly attached to Extruted Aluminium
frame work with 2 nos AXIAL FLOW FANs complete
with TEFC motor and vibration isolators. The fan should
be Hot Dipped Galvanised steel. The fan shall be selected
for low noise level and low RPM Fan motor shall be
suitable for 415 + 10% volts, 50 cycles, 3 phase power
supply. The smoke evacuation fan from the basement
shall be capable of work at 250 Deg c for at least 2 hours.
The unit shall be equiped with back draft dampers. Fan
capacity shall be as follows:
Non Fire rated ( for Fresh Air Supply)
1.1 Basement Parking Ventilation (level -2) 2 nos 8750 Nos. 2 -
CFM capacity 20 mm static for each fan in one fan box
RATE IN WORDS
Fire Rated ( For Exhaust)
1.2 Basement Parking Ventilation (level -2) 2 nos 8750 Nos. 4 -
CFM capacity 20 mm static for each fan in one fan box
RATE IN WORDS
2 Supply, installation, testing and commissioning of Single
skin Construction FAN BOX with GSS of minimum 1.6
mm Thickness rigidly attached to Extruted Aluminium
frame work with 1 nos DIDW FAN complete with TEFC
motor, belt drive, multi sheaved pulley mounted on motor
and fan shaft, belt guard, motor mount, and vibration
isolators. The fan should be Hot Dipped Galvanised steel.
The fan shall be selected for low noise level and low RPM
Fan motor shall be suitable for 415 + 10% volts, 50
cycles, 3 phase power supply. The smoke evacuation fan
from the basement and atrium shall be capable of work at
250 Deg c for at least 2 hours. Fan capacity shall be as
follows:
Non Fire rated ( for Fresh Air Supply)
2.1 Basement Parking Ventilation (level -2) 17500 CFM Nos. 2 -
capacity 20 mm static for each fan
RATE IN WORDS
3 Supply of Ductless Ventilation / Jet fans as per attached
specifications & Technical Details for Normal ventilation
and Smoke Extraction application. The complete fan
assembly with its Casing, impeller & motor (not only the
motor or one of the item) shall be imported from
o
manufacturer and certified as tested for 300 C for 2 hours
operation. Each fan shall be complete with motor and
impeller. Casing shall be made of Hot Dipped Galvanise
Steel. The motor shall be dual speed and shall be suitable
for 3phase 415 + (-) 10% volts, 50 Hz, A/C power supply.
The fan shall be suitable to operate at 250 Deg C for 2
hours.
3.1 Jet fans 400 mm dia Nos 6 -
RATE IN WORDS
4 Supply installation Testing and commissioing of Carbon Nos 3 -
Monoxide Sensor
RATE IN WORDS
Page 9
S. No. Description Unit Qty. Rate Amount
5 CFD (Computational Fluid Dynamics ) analysis for the Lot 1 -
basement from the jet fan manufacturer as per the
requirement of local fire safety norms and to ensure that
the jet fans are placed in a manner to ensure evacuation of
car exhaust / toxic fumes and smoke as and when
required.
RATE IN WORDS
6 Supply, installation, testing and balancing of inlet air Sqm. 9 -
louvers with bird screen and volume damper for fresh air
in powder coated extruded aluminium construction as per
specifications and approved shop drawings.
RATE IN WORDS
6 Main control panel (MCC 2) PLC based for basement
Ventilation
6.1 Supply of Electrical Panel with feeders and starters No 1 -
(basement 2)
a for 6 nos. 3 phase dual speed fans of 1.2 kw (high speed)
/ 0.24 kw (low speed) each and logic controller with
necessary logic for CO detectors and control of jet fans. 7
nos. CO sensor (shown separately below) will be
connected with each of the panel which will provide input
to the panel for running a particular numbers of fans of a
particular zone as described in sequence of operation
b. Suitable for 12 nos. 3 phase fans of 7.5 KW each fresh
air fans with starter
b. Suitable for 2 nos. 3 phase fans of 12.5 KW each fresh
air fans with starter
c. Suitable for 3 nos CO Sensor.
RATE IN WORDS
7 Supplying and laying of following 1100 volt grade PVC
insulated sheathed aluminium conductor armoured cables
/ copper cables on cable trays, in trenches (as per quantity
of cable trays and trenches included in BOQ separately),
on walls clamped to wall with suitable clamps, saddles,
and fixing bolts, or laying in ground including cost of
digging brick and sand protection, and including jointing /
connecting / terminating, testing and commissioning :
Page 10
S. No. Description Unit Qty. Rate Amount
Page 11
APPROVED MAKES OF EQUIPMENT & MATERIALS