Sie sind auf Seite 1von 4

Solar Air collector

GB
www.eurostar-solar.com

AIRSOL

Free Space Heating


No more humidity
AIRSOL HOME APPLICATIONS

AIRSOL SOLAR HEATER INSTALLATION ON WALL

is made by SOLE S.A. for space


heating, dehumidification and INSTALLATIONAIRSOL
ON WALL
45-65 oC

ventilation of buildings with SOLAR


IRRADIATION
HOT AIR

hot air. AIRSOL


WASHABLE 45-65 oC
AIR FILTER
HOT AIR
SOLARAIR INLET
FRESH
IRRADIATION

WASHABLE

How does it work? AIR FILTER on south, southeast and south


Easy installation
INSTALLATION
FRESH AIRON
west walls INLET TILE ROOF

The basic principle of this system is the following: SOLAR


IRRADIATION
INSTALLATION ON TILE ROOF
AIRSOL

SOLAR
Solar irradiation passes through the highly transmissive WASHABLE
AIR FILTER IRRADIATION
45-65 oC
HOT AIR
AIRSOL
FRESH AIR
glazing and reaches the absorber. The selective absorber INLET
18 oC
RETURN
GRILLE

WASHABLE
AIR FILTER
45-65 oC
transforms the irradiation into heat, which is heating HOT AIR
FRESH AIR RETURN
INLET GRILLE
18 oC
the air passing through.

The solar-heated air is transferred into the building,

by a ventilator, operated by photovoltaic panel.


Installation on inclined roof facing south, south east
and south west
The fresh air enters the device after being filtered, INSTALLATION ON FLAT ROOF

to be free from any particles and dust. SOLAR


IRRADIATION

FRESH
AIRSOL AIR INLET
The fan of the collector is powered by a P.V. panel FILTER

which ensures that the system works even when 45-65 oC


HOT AIR

nobody is in the building, keeping rooms warm,

fresh and dry without any odors.

In a building (house) with flat roof and ducts.


www.eurostar-solar.com
www.eurostar-solar.com

AIRSOL
SOLAR AIR COLLECTOR FOR SPACE HEATING

Advantages COMMERCIAL APPLICATIONS WITH


AIRSOL COLLECTORS IN SERIES

Direct heating for free with solar energy: COMMERCIAL AUTONOMOUS

SOLAR
Saving of conventional fuel for heating from IRRADIATION
AIRSOL

50-80% in houses or commercial buildings.


FRESH AIR INLET
VIA DAMPER
Ideal for country weekend houses, keeping
them hot and fresh. No more humidity.
COMMERCIAL AUTONOMOUS
18-20 oC HOT AIR 45-65 oC

Ideal for places that need heating and air SOLAR


THERMOSTAT FAN
AIRSOL
renewal such as: IRRADIATION

- schools
- offices FRESH AIR INLET
VIA DAMPER

- factories Recommended for


Industry Schools
COMMERCIAL COMBINED
Super markets HOT
Offices
Ideal for closed rooms such as underground
o
18-20 C AIR 45-65 oC
Army camps Hospitals
warehouses etc. SOLAR
THERMOSTAT
Hotels
IRRADIATION
FAN
AIRSOL Gyms
Warehouses
Very easy installations even do it your self. In general wherever you need heating,
FRESH AIRdehumidification,
INLET and filtered fresh air.
VIA DAMPER

Md .H.U.

d
COMMERCIAL COMBINED
18-20 oC HOT AIR 45-65 oC
FAN

Free heating, SOLAR


THERMOSTAT
IRRADIATION
AIRSOL

with solar energy BURNER

FRESH AIR INLET


VIA DAMPER

Md .H.U.

18-20 oC HOT AIR 45-65 oC


FAN

THERMOSTAT

BURNER

It can be used either as the only source of heating or


as a back-up one. It can be combined with any oil or
natural gas boiler (burner).
Since its foundation in 1974, SOLE S.A. has been committed to
the protection of the environment and the reduction of CO
emission. SOLE S.A. holds numerous prizes and distinctions,
contributing with its products to the improvement of the
environment in all 5 continents.

The solar heater AIRSOL is produced in 3 sizes with blue selective surface made of full face selective
aluminum sheet for maximum efficiency.

TYPE DIMENSIONS (mm) SURFACE m NOMINAL POWER** RECOMMENDED


FOR ROOM AREA

AIRSOL 10 1492x658x170 0,98 700Wp 10 to 40 m


AIRSOL 20 2050x1040x195 2,13 1500Wp 20 to 60 m
AIRSOL 35 2830x1280x140 3,62 2700Wp 35 to 100 m
** Values calculated with a solar irradiation of 1000w / m
For permanent residence or premises of everyday use just select the lowest value of room area for better
performance and fuel savings of more than 50%.
For country or vacation houses and other places with lower heating needs and mainly with ventilation
and dehumidification needs, select the highest value of room area.

AIRSOL 1.0 / 2.0 / 3.5 m2 AIRSOL 1.0 / 2.0 / 3.5 m2 AIRSOL 1.0 / 2.0 / 3.5 m2
OUTLET vs INLET AIR TEMPERATURE OUTLET vs INLET AIR TEMPERATURE
RECIRCULATION 100% FRESS AIR
: OUTLET MINUS INLET AIR TEMPERATURE

Das könnte Ihnen auch gefallen