PROVISIONING
Addition of a new timing source is configured in the Set Timing Source dialog box by
clicking the Add button on the upper left of the Setup-Timing Source Configuration
dialog box. Perform the procedure described in the subsection 4.2.4.2 Procedure: Add
New NE Timing Source.
Modification and deletion of a timing source can also be operated. For this operation, click
the Modify or Delete button on the upper left of the dialog box. Perform the procedure
described in the subsection 4.2.4.3 Procedure: Modify NE Timing Source or 4.2.4.4
Procedure: Delete NE Timing Source respectively.
In addition, the switching type can be set for each timing source in the Set Clock Extra
Commands dialog box, which will be opened by clicking the Switch button on the top
of the Setup-Timing Source Configuration dialog box. Refer to the subsection
4.2.5.2 Procedure: Setup Timing Source Switching Type for the procedure.
The Setup-Timing Source Configuration dialog box has the following items
and parameters:
Auto Reserved DNU 0 thru 255 Value 0 means the Auto Reserved DNU
Group ID Group ID is invalid.
Hold off Time 0 thru 1800 Set Hold-off time, which is the duration to hold
(ms) QL until the operating timing source switches
to be available upon failure of this timing
source. The step is 300 ms.
WTR Time 0 thru 7200 Set Wait To Restore time, which is the amount
(sec) of time to wait before a recovered timing
source becomes active again. The step is 60s.
Priority 1 thru 256 Set the priority of timing source
manually. The highest priority is 1, and the
lowest is 256.
2. Click the Add button on the upper left of the Setup-Timing Source
Configuration dialog box. The Set Timing Source dialog box shown in
Figure 4-5 appears:
5. Set values for the Receive SSM Set Value, Transmit SSM Mode and
Force Transmit SSM Value combo boxes on the right of the dialog box,
using the drop-down list.
6. Set the Hold Off Time (0 thru 1800 ms) and WTR Time (0 thru 7200 s).
9. Confirm the entered items, and click the OK button. The Set Timing Source
dialog box disappears, and the Setup-Timing Source Configuration dialog
box is displayed again with the specified timing source in the list.
NOTE: Clicking the Close button instead of the OK button cancels adding the
NE timing source, back to the Setup-Timing Source Configuration
dialog box ignoring all the settings.
10. Click the Retrieve button on the bottom of the Setup-Timing Source
Configuration dialog box to retrieve the timing source configuration data in
MCP.
Register NE Configuration Setup NE
4-12
F2880_B10
PROVISIONING
x To set the switching type for timing sources, click the Switch button on the
upper right of the Setup-Timing Source Configuration dialog box to
open the Set Clock Extra Commands dialog box. Then go to the
subsection 4.2.5 Setup Timing Source Switching Type.
x To forward the NE setup, click the Next button on the bottom of the
Setup-Timing Source Configuration dialog box to open the
Setup-Timing Source Attribute dialog box. Then go to the subsection
4.2.6 Setup NE Clock Module Configuration.
x To go back to the NE slot configuration setup, click the Back button to return
to the Setup-Physical Slot Configuration dialog box.
2. Select a timing source to be modified from the list by clicking. Then the Modify
and Delete buttons becomes valid.
3. Click the Modify button on the upper left of the Setup-Timing Source
Configuration dialog box. The Set Timing Source dialog box shown in
Figure 4-6 appears:
4. Modify the necessary parameters by referring to the procedures for adding a new
timing source, provided in the subsection 4.2.4.2 Procedure: Add New NE
Timing Source.
5. Confirm the entered items, and click the OK button. The Set Timing Source
dialog box disappears, and the Setup-Timing Source Configuration dialog
box is displayed again with the modified timing source in the list.
NOTE: Clicking the Close button instead of the OK button cancels the NE
timing source modification, back to the Setup-Timing Source
Configuration dialog box ignoring all the settings.
x To set the switching type for timing sources, click the Switch button on the
upper right of the Setup-Timing Source Configuration dialog box to
open the Set Clock Extra Commands dialog box. Then go to the
subsection 4.2.5 Setup Timing Source Switching Type.
x To forward the NE setup, click the Next button on the bottom of the
Setup-Timing Source Configuration dialog box to open the
Setup-Timing Source Attribute dialog box. Then go to the subsection
4.2.6 Setup NE Clock Module Configuration.
x To go back to the NE slot configuration setup, click the Back button to return
to the Setup-Physical Slot Configuration dialog box.
2. Select a timing source to be deleted from the list by clicking. Then the Modify
and Delete buttons becomes enabled.
3. Click the Delete button on the upper left of the Setup-Timing Source
Configuration dialog box.
x To set the switching type for timing sources, click the Switch button on the
upper right of the Setup-Timing Source Configuration dialog box to
open the Set Clock Extra Commands dialog box. Then go to the
subsection 4.2.5 Setup Timing Source Switching Type.
x To forward the NE setup, click the Next button on the bottom of the
Setup-Timing Source Configuration dialog box to open the
Setup-Timing Source Attribute dialog box. Then go to the subsection
4.2.6 Setup NE Clock Module Configuration.
x To go back to the NE slot configuration setup, click the Back button to return
to the Setup-Physical Slot Configuration dialog box.
The Set Clock Extra Commands dialog box has the following items and
parameters:
1. Confirm that the Set Clock Extra Commands dialog box shown in Figure
4-7 is displayed:
3. Select the target timing source for which the switching type is set from the list.
4. Select the switching type to Lock Out, Forced Switch or Manual Switch by
clicking a check box.
6. Click the Close button. The Set Clock Extra Commands dialog disappears
and the Setup-Timing Source Configuration dialog box is displayed again.
x To forward the NE setup, click the Next button to open the Setup-Timing
Source Attribute dialog box. Then go to the subsection 4.2.6 Setup NE
Clock Module Configuration.
x To go back to the NE slot configuration setup, click the Back button to return
to the Setup-Physical Slot Configuration dialog box.
The Setup-Timing Source Attributes dialog box has the following items and
parameters:
(Contd)
ITEM/PARAMETER VALUES DESCRIPTION
2. Select the target system timing source from the list box.
3. Click the check box (leaving a tick) on the left of Revertive to enable the
recoverability.
5. Select the timing source threshold from the Timing Source Threshold
drop-down list.
NOTE: Clicking the Retrieve button on the bottom of the dialog box retrieves
the attribute data of specified timing source in MCP.
x To forward the NE setup, click the Next button to open the Setup-Others
dialog box. Then go to the subsection 4.2.7 Complete NE Setup.
x To go back to the timing source configuration setup, click the Back button to
return to the Setup-Timing Source Configuration dialog box.
Procedure
1. Confirm that the Setup-Others dialog box shown in Figure 4-9 is displayed:
2. Click the Download check box (leaving a tick) to download any data to the NE.
x To modify any settings for NE setup again, click the Back button to go back
to the Setup-Timing Source Attribute dialog box.
x To complete the setting for NE setup (initialization), click the End button.
This step is the end of all the procedures for NE setup operation.
1. Open the management dialog box of the target NE. Detailed operation is
provided in the section 7. Operating with CID of the CID Operating Guide
manual.
2. From the main menu on the NE management dialog box, select Set
Output-Clock Port from the Configuration menu. The Set Output-Clock
Port dialog box shown in Figure 4-10 appears:
4. Select the Output Status from the Output Status drop-down list.
5. Select the Timing Source Threshold from the Squelch drop-down list.
6. Click the Set button to send the data down to NE. The entered port will be
displayed in the Output-Clock Port list.
7. Click the Retrieve button to report the port installation condition to the CID.
Installation of a port is operated in the Port Configuration dialog box by using CID.
1. Open the management dialog box of the target NE. Detailed operation is
provided in the section 7. Operating with CID of the CID Operating Guide
manual.
2. From the main menu on the NE management dialog box, select Port
Configuration from the Configuration menu. The Port Configuration
dialog box shown in Figure 4-11 appears:
5. Select the port type to be installed from the drop-down list on the right of Set:
Configured Port Type.
6. Click the Set button to send the data down to NE. The entered port will be
displayed in the Configured Port Type text box.
NOTE: The added port type displayed in Configured Port Type must match
that in Installed Port Type. Refer to the subsection 4.4.2 Port
Location for the correct port type.
7. Click the Retrieve button to report the port installation condition to the CID.