Sie sind auf Seite 1von 2

Reflex Sensor

for Measuring Tasks

YP11MGVL80 LASER
Part Number Technical Data
Optical Data
Working Range 50...100 mm
Measuring Distance 75 mm
Measuring Range 50 mm
Resolution < 25 m
Linearity 0,5 %
Light Source Laser (red)
Wave Length 660 nm
Service Life (T = +25C) 100000 h
Laser Class (EN 60825-1) 2
max. Ambient Light 10000 Lux
Light Spot Diameter 1 mm
Electrical Data
Supply Voltage 18...30 V DC
Current Consumption (Ub = 24V) < 30 mA
Cut-Off Frequency 100 Hz
Response Time 5 ms
Temperature Drift (Tu < 10C, Tu > 40C) 20 m/K
Temperature Drift (10C < Tu < 40C) 10 m/K
Temperature Range -10...60 C
Error Output Voltage Drop < 2,5 V
PNP Error Output/Switching Current 200 mA
Analog Output 0...10 V
Linearity: 0,5 % Short Circuit Protection yes
Measuring Range: 50 mm Reverse Polarity Protection yes
Overload Protection yes
Resolution up to 20 m Mechanical Data
Housing Plastic
Full Encapsulation yes
Degree of Protection IP67
Connection M12 x 1
Protective Insulation, Rated Voltage 50 V
Error Output
Analog Output
Connection Diagram No. 503

Control Panel No. P3

Suiting Connection Technology No.


Suiting Mounting Technology No. 380

These sensors are equipped with an analog output and


can thus be utilized for measuring tasks. The output sig-
nal is practically independent of the objects color. High
resolution and a wide variety of measuring ranges allow
for use in innumerable applications.

LASER CLASS 2
EN60825-1 50 V
All dimensions in mm (1 mm = 0.03937 Inch)

1 = Transmitter Diode
2 = Receiver Diode

503 Legend

Supply Voltage + Test Input


Supply Voltage 0V Test Input inverted
Supply Voltage (AC Voltage) Trigger Input
Switching Output (1,2,3...)/NO Analog Output
Wire Colors according to
Switching Output (1,2,3...)/NC Ground for the Analog Output DIN IEC 757
Contamination/Error Output (NO) Block Discharge
Contamination/Error Output (NC) Valve Output Black
Input (analog or digital) Valve Control Output + Brown
Teach Input Valve Control Output 0V Red
Time Delay (activation) Synchronization Orange
Shielding Receiver-Line Yellow
RS-232 Receive P ath Emitter-Line Green
RS-232 Send Path Grounding Blue
Ready Switching Distance Reduction Violet
Ground USB data + Grey
Clock USB data - White
Output/Input programmable Interfaces-Bus A(+)/B(-) Pink
Emitted Light disengageable Green Yellow

Complimentary Products
Analog Evaluation Unit AW02
Error of Measurement
Protection Housing Set ZSP-NN-02
Typical characteristic curve based on Kodak white, 90 %
Protection Housing ZSV-0x-01
YP11MGV80
Ctrl.Panel 3.0
Specifications are subject to change without notice

P3 2.5
dSr/mm

2.0
03
1.5
12
1.0

0.5

0.0

-0.5
50 55 60 65 70 75 80 85 90 95

Sr/mm
Sr = Switching Distance black 6 %
03 = Error Indicator
12 = Analog Output Indicator dSr = Switching Distance Change Aluminum

Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com