CAPACITY OF THE AGAR MPFM-300 SERIES:

Total Volumetric Capacity (Range)

MPFM Model No. M3/D BBL/D


Process Measurement & Control
Min. Max. Min. Max. * Not all models and capacities are listed. Volumetric

300-10 10 198 60 1,250


capacities are for 0.5 - 100 cP viscosity range. Capacities
vary by viscosity, temperature, liquid/gas ratio, pressure
MPFM 300 Series
and other factors. Contact factory for specific application Multiphase Flow Meter (Oil/Water/Gas)
300-15 24 500 150 3,100 information.

300-20 40 800 250 5,000


AGARs MPFM 300 is a true multiphase flow meter that
300-30 79 1,600 500 10,000
provides on-line, real-time well production information for oil,
300-40 159 3,180 1,000 20,000 water and gas flow rates without separation of the phases. No
longer is there a need for expensive, secondary equipment
300-60 382 7,600 2,400 48,000
such as phase separators and pumps. The MPFM-300
Series is fully self-contained and compact for use in rugged
This graph shows the effect of Gas to Liquid Ratio (GLR) on liquid capacity of the MPFM-300:
field conditions.

MPFM-300 Installation on an
Offshore Platform
ACCURACY:
Accuracies are not affected by changes in Worst Case Instantaneous Errors (Quoted to 1 sigma):
Features of the AGAR MPFM-300 Series include:
salinity, viscosity, density, temperature,
pressure, or pH. Oil Flow Rate 2% of full scale, plus 5% of reading
Highly accurate, real-time flow measurement

Water Flow Rate 2% of full scale, plus 5% of reading Self-verification capability in the field

No nuclear (radioactive) sources
Gas Flow Rate 5% of full scale, plus 5% of reading
The ability to be used in all flow patterns

Total Fluid Flow Rate 2% of reading
Requires little maintenance

Compact, portable, and easy to transport and install
USA CAYMAN ISLANDS VENEZUELA MALAYSIA ABU DHABI INDONESIA Not affected by changes in fluid properties

Agar Corporation Agar Corporation Ltd. Agarcorp de Venezuela C.A. AgarCorp SDN. BHD. Agar Corporation (ACAD) PT AgarCorp Indonesia MPFM-300 Installation -
5150 Tacoma Drive P.O. Box 10206 77 Edif. 5 de Julio, Piso 4, Ofiicina 168-1st Fl Main Rd Salak So 1505, Three Sails Tower Jalan Teratai CB-17 Application - Well Testing and
Measures in both oil- and water-continuous phases
Houston, TX 77041 Grand Cayman, BWI D-4, Sector Tierron Negra, Zona 57100 Kuala Lumpur Corniche, Khalidiya Ciputat Baru, Ciputat Diluent Optimization at high
Gas void fraction 0-97%
Tel: (832) 476-5100 KY1-1002 Postal 4002, Maracaibo, Edo. Zulia Tel: 603-7980-7069 Abu Dhabi, UAE Tangerang 15413 viscosity operation
Fax: (832) 476-5299 Tel: (345) 945-5242 Tel: +58 261 324 5789 Fax: 603-7980-5369 Tel/Fax: 971-2681-1779 Tel: 62 21 7409206
ACI@agarcorp.com ACL@agarcorp.com ADV@agarcorp.com ACSB@agarcorp.com ACAD@agarcorp.com PTAI@agarcorp.com

www.agarcorp.com
www.agarcorp.com All Agar Corporation Instruments are covered by one or more of the following U.S. Patents: 4,503,383; 4,774,680; 5,099,697; 5,101,163; 5,101,367;
5,263,363; 5,503,004; 5,551,305; 5,589,642; 5,741,977, RE 36,597. Other patents pending in the USA and other countries.
ER No. 4967: SL0002 Rev -
MPFM 300 Series Features MPFM 300 General Specifications
PROCESS CONDITIONS
The AGAR MPFM-300 Multiphase Flow Meter provides accurate measurements of oil/gas/water flowing Instantaneous Void Fraction 0 to 97%
simultaneously, without physically separating the phases. The system can be used in all flow patterns with both oil- Watercut 0 to 100%

continuous and water-continuous fluid streams. The MPFM-300 Series is specially designed for low maintenance Flow Patterns All: (e.g. Bubbly, Wavy, Slug, Annular flows, etc.)
Design Pressure Up to ANSI 1500#, Contact factory for higher ratings
and ease of operation. No field calibration or prior knowledge of the fluid properties, such as density and salinity,
Ambient Temperature -4F to 158F (-20C to 70C)
is required to attain the specified accuracies.
Optional Low Temp -40F to 158F (-40C to 70C)
Process Temperature Standard Model 32F to 212F (0C to 100C)
High Temperature Model 32F to 450F (0C to 232C)
AGAR Corporations patented technology Viscosity 0.5 to 5000 Centipoise (Calibrated in two ranges: 1 - 100cP and 100 -
achieves unprecedented accuracy in 5000cP)
multiphase measurements. Salinity Up to 0 to 20% by weight
Sand/Particulate Up to 5% by volume
Max. Pressure Drop Less than 15 PSI (1 bar)
Primary Sub-Systems Corrosion Resistance Standard NACE MR-01-75
Wetted Parts Stainless Steel; Carbon Steel; Teflon; Ceramic, PEEK
Four subsystems are used to achieve accuracy. These include:
Other uses available per request.
The Volumetric Flow Meter is a positive displacement TYPICAL DIMENSIONS: (ANSI 300, Down-leg and Skid-Mounted Options)
meter that accurately measures the total flow (gas Weight Dimensions (F/FXWXH)
and liquid). It is selected from a range of commercially Model
(Lbs.) (Kg.) Inches Centimeters
available products with proven field records and
the volumetric flow data is fed into the MPFM Data 301-20 1200 545 44x35.5x100 111x90x254
Analysis System (DAS), which performs calculations 301-30 1700 773 44x35.5x115 111x90x292
for the multiphase measurement. 301-40 2100 955 60x52x123 155x132x312
The AGAR Momentum Meter uses a unique venturi 301-60 3700 1682 70x62x146 178x157x418
configuration to establish the gas volume fraction of
ELECTRICAL
the flow stream. Data from the momentum meter is Power Supply: 110, 220 VAC, 24 VDC (Optional)
fed into the MPFM DAS. Power Requirements: 36 Watts with pneumatic actuator
The AGAR Watercut Meter (OW-201) is a LOCAL DISPLAY
microwave-based oil/water monitor. The OW201 4 Line LCD integrally mounted
uses a microwave transmitter broadcasting at over
2 Gigahertz and receivers to measure bulk electrical SAFETY CERTIFICATIONS
properties of the fluid. Engineering advances allow ATEX - EEx ia IIC T6
the OW-201 to measure water content accurately UL/C-UL - Class 1, Division 1, Group C & D, T4
over the full range of 0-100% in both oil and water- DATA COMMUNICATION (STANDARD AND OPTIONAL)
continuous phases. Accuracy is not affected
by changes in velocity, salinity, pH, viscosity, Standard: LCD display, keyboard monitor and laptop are optional
temperature or density. Watercut data is fed into the Standard: MPFMWin software to indicate Temperature; Pressure; Volumetric Flow Rate of
MPFM DAS. Gas, Oil, Water, and Total Flow.
Standard: MPFMWin software indicating Time trending and bar graphs of gas, oil and water flow
The AGAR Data Analysis System (DAS) performs rates, temperature, and pressure.
Standard: One RS232 and one RS485 outputs (baud rate up to 1115.2 Kbps), Modicon MODBUS
on-line analysis of data acquired from the above
and ASCII protocol. Other types optional.
subsystems to determine the oil, water, gas, and total Standard: Hard Disk, Floppy Drive.
fluid flow rates. Standard: Analog Output Card to handle up to 6 outputs: 4-20 mA / 1-5VDC / 2-10VDC / 0-5VDC /
0-10VDC / Relay / Pulse Outputs or a combination of the above
Optional: Analog Input Card

World-Class Process Measurement & Control Solutions www.agarcorp.com